ATC300 Temperature Controller ATC300 Temperature Controller
ATC300 Temperature Controller ATC300 Temperature Controller
The controller will now switch on the socket marked (I) on the
plugbar when the current temperature(T) falls below the
temperature set above.
The heater led display will light when the heater socket (I) is in
operation.
Alarm
The alarm will sound when the current temperature falls below
the set temperature - the alarm offset.
The alarm can be cancelled by pressing any key
To disable the alarm permanently press the ▲ key ▼ key
together, the display will show 8_c to indicate the alarm has been
disabled and 8_o to indicate the alarm is operational.
ATC300 Temperature Controller ATC300 Temperature Controller
Checking The Settings
Setting The Timer Press the TEMP key to cycle through the current set temperature
Hold down the TIME key for 3 seconds until the display flashes. and Alarm offset. The diplay will return to normal after 2
The display will now show “o” followed by 2 digits. Use the ▲ seconds.
key to increase the time and the ▼ to reduce the time. Press the TIME key to cycle through the on and off time settings.
This is the time the that the socket (II) on the plugbar will operate The diplay will return to normal after 2 seconds.
for, from the time the settings are saved.
The time can be set between 0-24Hrs. Error Displays
Press the TIME key again “c” will be displayed followed by 2 If the temperature reading is greater than 50ºC the display will
digits. Use the ▲ key to increase the time and the ▼ to reduce show “HHH” and an alarm will sound.
the time. If the temperature reading is lower than 0ºC the display will
This is the time that the socket (II) on the plugbar will be turned show “LLL” and an alarm will sound.
off after the “on-time” has elapased. In the unlikely event of a sensor failure then “EEE” will be
The time can be set between 0-24Hrs. displayed and an alarm sound, the socket output (I) will be turned
Hold down the TIME key for 3 seconds to save your settings. If off
you do not want to save your settings the unit will return to it’s
previous settings and temperature display after 15 seconds.
Specification
Example: • Control Range: 0-50ºC • Measuring range: 0-50ºC
If you wanted to use the timer to control fans that come on at the • Distinguish: 0.1ºC • Accuracy: ±1ºC
same time as your lights 11am till 10pm. Wait until 11am then • Temperature Offset 1ºC • Overheat Alarm 1-5ºC
follow the above instructions setting the “on time” to 11Hrs and • Input Voltage: 220V ±10% 50-60Hz
the “off time” to 13Hrs. The timer will then be repeated each day. • Product Consumption: ≤ 3w
•Control Load: ≤ 1200w / 220VAC