IEC TS 60079-46 is a new technical specification for certifying equipment assemblies for use in potentially explosive atmospheres. It incorporates the inspection requirements of IEC 60079-14 but also verifies other ignition hazards. Compliance with IEC TS 60079-46 indicates an overall protection level for the assembly. Assemblies can be certified through type verification which requires ISO/IEC 80079-34 compliance, or unit verification which requires competency substantiation. The certification covers electrical and non-electrical ignition hazards and allows the assembly to be marked accordingly.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
79 views
Compliance Solutions - Unit Verification
IEC TS 60079-46 is a new technical specification for certifying equipment assemblies for use in potentially explosive atmospheres. It incorporates the inspection requirements of IEC 60079-14 but also verifies other ignition hazards. Compliance with IEC TS 60079-46 indicates an overall protection level for the assembly. Assemblies can be certified through type verification which requires ISO/IEC 80079-34 compliance, or unit verification which requires competency substantiation. The certification covers electrical and non-electrical ignition hazards and allows the assembly to be marked accordingly.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8
COMPLIANCE SOLUTIONS – UNIT VERIFICATION
ARE THE GO-TO COMPANY WHEN IT COMES TO HAZARDOUS AREA CONCERNS Assemblies to IEC TS 60079-46
IEC TS 60079-46 is a new technical specification for the certification
of ‘Assemblies’ that has been adopted as a certification standard for issuing Certificates of Conformity for an Assembly designed to be used in Potentially Explosive Atmospheres. IEC TS 60079-46 incorporates the inspection requirements of IEC 60079-14, but also includes the full ‘overall safety’ including other forms of ignition (such as mechanical heat or friction) that may not normally be verified. Compliance with IEC TS 60079-46 indicates an overall protection level for the skid, not just the electrical parts used on the skid. Assemblies to IEC TS 60079-46
For equipment assemblies subjected to Type Verification to IEC TS
60079-46 , the manufacturing process and the competency of the related personnel shall conform to ISO/IEC 80079-34. The assembler is to have an IECEx Quality Assurance Registration (QAR) in place listing IEC TS 60079-46.
Alternatively, for equipment assemblies subjected to ‘Unit
Verification’ (certified by serial number by final inspection) the competency of the personnel performing the production processes is substantiated by ATEC Assemblies to IEC TS 60079-46
The certification covers both the Ex Electrical and Non-electrical
items and the interconnection wiring system. The Ignition hazard assessment covers all explosion ignition related hazards and the inspection and assessment to IEC 60079-14. When these are deemed compliant, the ‘Assembly’ can be marked with “60079-46” as the type of protection with the overall gas group and temperature classification, EPL and ambient temperature range. Assemblies to IEC TS 60079-46 IECEx
As of January 1st 2020 all IECEx Assembly Certification must be to
IEC TS 60079-46 which covers both electrical a and non-electrical ignition hazards. IECEx Certification provides “proof of compliance” with safety standards for Assemblies of Ex products that come together in the form of functioning equipment. The IECEx Certificate to IEC TS 60079-46 provides evidence that all ignition hazards (electrical and non-electrical) have been suitably addressed and that the installation is of the required standard. The final assembly will be marked with a single marking covering the complete assembly or skid including the symbol “Ex” and any important information regarding the safe use of the assembly. Assemblies to IEC TS 60079-46 ATEX and UKCA Assemblies
ATEX and UKCA Assemblies can be certified in the same way by
ATEC’s “ATEX Notified” and “UKCA Appointed” Bodies respectively. The assembly will then be checked by our accredited experts for all ignition sources (not just electrical) on certified and non-certified parts and have the appropriate documentation (RA/DSD’s etc), Installation and Equipment Protection Level (and Category) verified and marked on one overall label. Sample of Certification