Floor Eposil Plus: Solvent Free Epoxy Sealing Primer

floor eposil plus is a two-component, solvent-free epoxy primer used to seal porous substrates before applying epoxy or polyurethane coatings. It improves adhesion and provides chemical and abrasion resistance. The primer has a pot life of 1 hour, dries within 24 hours, and can be applied using rollers, brushes or sprayers at a rate of 0.15 kg/m2. It is recommended for use on parking decks, bridge decks, industrial floors and in the food industry.

Uploaded by

Maha Mufleh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
70 views2 pages

Floor Eposil Plus: Solvent Free Epoxy Sealing Primer

floor eposil plus is a two-component, solvent-free epoxy primer used to seal porous substrates before applying epoxy or polyurethane coatings. It improves adhesion and provides chemical and abrasion resistance. The primer has a pot life of 1 hour, dries within 24 hours, and can be applied using rollers, brushes or sprayers at a rate of 0.15 kg/m2. It is recommended for use on parking decks, bridge decks, industrial floors and in the food industry.

Uploaded by

Maha Mufleh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

floor eposil plus Formerly "Eposil plus" FLOORING

Solvent free epoxy sealing primer

PRODUCT
floor eposil plus is a high quality two-component epoxy
primer designed to seal the porosity of the substrate thus
providing a homogeneous and adherent surface to various
epoxy and polyurethane coating systems. It can also be
used as a bonding coat for epoxy mortars. It provides superior
resistance of concrete to chemicals and daily abrasion, and
reduces its absorption of water and salts.

SCOPE OF USE
• Parking decks
• Bridge decks
• Industrial floors
• Food industry flooring

CHARACTERISTICS
Color Transparent PACKAGING
Solid content 100% by volume Leb Syria Jordan UAE Qatar Kuwait KSA Oman
Density 1.07 3.4 Kg 3.4 Kg 3.4 Kg 3.4 Kg 3.4 Kg 3.4 Kg 3.4 Kg 3.4 Kg
Pot life 1 hour at 30°C 12 Kg 12 Kg 12 Kg 12 Kg 12 Kg 12 Kg 12 Kg 12 Kg
Max over coating delay 1 day
VOC and formaldehyde None (<10µg/l)
content ISO/FDIS
11890-2/GC-MS
For very porous surfaces two coats may be required to seal
effectively.
INSTRUCTIONS FOR USE
floor eposil plus must be over coated within 24 hours. If
SURFACE PREPARATION
it is not possible, aggregates 0.1-0.4 mm must be strewn on
Careful surface preparation is essential for optimum finishing
the wet applied floor eposil plus.
and durability.
Maximum moisture content should not exceed 5%.
New concrete structures need to dry for at least 28 days. Old CONSUMPTION
coatings, dirt, fats, oils or organic substances need to be 0.15 kg/m²
removed by a grinding machine. Possible surface irregularities The concrete surface greatly affects coverage rate.
need to be smoothened. Any loose surface pieces need to be
thoroughly removed. The surface should then be roughened STORAGE
using a dust-free “grit-blasting” machine. One year after manufacturing date in its original packing non
The substrate should be clean, dry and sound, free of any open and in dry cool area.
dust or contamination which may harmfully affect the
adhesion of the primer layer. SAFETY PRECAUTIONS
WARNING: Do not wash surface with water! Application should be done in a ventilated area away from
any heat source. Wear protective gear for hands and eyes
PRODUCT PREPARATION and avoid breathing of vapor. If mixed resin comes into
Mix the two parts for 2-3 minutes by an electric mixer with contact with the skin, it should be promptly removed before
low rotation speed (< 300 rpm). hardening, followed by thoroughly washing the skin with
The epoxy must be well mixed to ensure proper chemical soap and water. In case of heavy vapor inhalation, place
reaction. After mixing, apply immediately. affected person in an open-air area. In case of contact with
eyes, wash thoroughly with clean water. If swallowed, do not
PRODUCT APPLICATION induce vomiting. In all cases, seek medical attention. In case
floor eposil plus is applied using a roller, brush or an of fire, use CO2 foam to extinguish. Tightly seal containers
airless sprayer. when not in use, store them away from heat and carefully
dispose empty ones.

1/2 Technical data sheet . Edition: 08.14-A www.sodamco-weber.com


floor eposil plus FLOORING

DISCLAIMER
While the company guarantees its products against defective
materials, the use and application of these products are
made without guarantee since the conditions of their
application are beyond its control. It is recommended to
verify with the company that the product is suitable for the
intended use, and that this Data Sheet version is the latest
one. The company may modify it without prior notice. Technical
characteristics are listed for guidance only. For more
information, please contact the company’s office in your
location.

NOTE
The information included on this Technical Data Sheet is the
sole property of weber. The unauthorized disclosure, use,
dissemination or copying (either whole or partial) of this data
sheet or any information it contains, is prohibited and
subject to legal pursuit.

PG:22

2/2 Technical data sheet . Edition: 08.14-A www.sodamco-weber.com

You might also like