Loadings - NSCP 2015
Loadings - NSCP 2015
Main objectives
1) Calculate Wind Pressure for Components and Cladding per NSCP 20
2) Design the Roof Truss and Purlins per NSCP 2015/AISC 360-10 by LR
3) Derive dead load and live load values per NSCP 2015
4) Discuss NSCP 2015/UBC 97 Seismic parameters input to STAAD
5) Design the concrete elements in STAAD Advanced Concrete Designe
(beams, slabs, columns and footings)
SIDENTIAL STRUCTURE USING
Concrete Designer RCDC
GF to 2F 4.5
2F - 3F 3
3F-ROOF 3
10.5
PROPERTIES
Beams Columns Slabs fc' fy
B-1 300x450 RC300X300 S110 20.68 Mpa 275 Mpa
B-2 250x400 S100 20.68 Mpa 276 Mpa
RB-1 250x350 20.68 Mpa 277 Mpa
LOADS
Dead Load
1) Selfweight
Concrete unit weight = 24 kN/m3
2) Member Load
150mm CHB 3.11 kN/m per meter height
100mm CHB 2.98 kN/m per meter height
Live Load
1.9 kN/m2
Seismic Parameters
UBC 97 / NSCP 2015
Zone = 4
Seismic Source Type = A
Importance Factor ( I ) = 1.0 (Standard Occupancy)
R = 8.5 - Special Moment Frame
Structure is located 40km from seismic source
Ct = 0.0731
2.63 0.24 0.24 3.11
2.5 0.24 0.24 2.98
UBC 1997
If Ft≠ 0:
Ft = 0.07TV UBC Eq. (30-14)
= 9.24 KN
< 0.25V = 96.73
1 1.400 D
1 1.200 D + 1.600 Lp
1 1.420 D + 0.500 Lp + 1.250 E1
1 1.420 D + 0.500 Lp + 1.250 E2
1 1.420 D + 0.500 Lp - 1.250 E1
1 1.420 D + 0.500 Lp - 1.250 E2
1 1.420 D + 1.250 E1
1 1.420 D + 1.250 E2
1 1.420 D - 1.250 E1
1 1.420 D - 1.250 E2
1 0.680 D + 1.250 E1
1 0.680 D + 1.250 E2
1 0.680 D - 1.250 E1
1 0.680 D - 1.250 E2
E = ρ Eh + Ev
1.25
= 1.25 Eh
Ev = 0.5 Ca I DL
0.5 0.44 1 DL
= DL
= 0.22 DL