0% found this document useful (0 votes)
132 views

Type 4

This document contains a bill of quantities for structural, architectural, and services works for a typical secondary school buildings project. It includes quantities for: 1. Structural and architectural works 2. Sanitary works 3. Electrical works 4. Mechanical works It also provides general notes on the works, including specifications for materials, safety measures, removal of debris, submittal requirements, and other construction notes. The quantities listed are estimated based on design drawings and site surveys.

Uploaded by

Saleem Akhtar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
132 views

Type 4

This document contains a bill of quantities for structural, architectural, and services works for a typical secondary school buildings project. It includes quantities for: 1. Structural and architectural works 2. Sanitary works 3. Electrical works 4. Mechanical works It also provides general notes on the works, including specifications for materials, safety measures, removal of debris, submittal requirements, and other construction notes. The quantities listed are estimated based on design drawings and site surveys.

Uploaded by

Saleem Akhtar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 105

MINISTRY OF CONSTRUCTION,HOUSING AND PUBLIC MUNICIPALITIES NATIONAL

BILL OF QUANTIYIES
FOR STRUCTURAL, ARCHITECTURAL AND SERVI
Typical School Buildings Project(Districts & Sub- Districts
SECONDARY SCHOOL (18) CLASSES

Contents:-
1-Intermediate Or Secondary School (18) Classes works/Type No (4)
2- Site Works

MINISTRY OF CONSTRUCTION,HOUSING AND PUBLIC MUNICIPALITIES NATIONAL


BILL OF QUANTIYIES
FOR STRUCTURAL, ARCHITECTURAL AND SERVI
Typical School Buildings Project(Districts & Sub- Districts
SECONDARY SCHOOL (18) CLASSES SCHOOL BU

Contents:-
1- Bill of Quantities for Structural and Architectural Works
2- Bill of Quantities for Sanitary Works
3- Bill of Quantities for Electrical Works
4- Bill of Quantities for Mechanical Works

GENERAL NOTES
1- All the items in B.O.Q. consist of supplying and transporting materials, working and fixing, inspection and operation acc
writing and the technical specifications.
2- The B.O.Q do not include the furnishing works and the responsibility for these works falls on the shoulders of the benefi
3- All materials used are from sober, reliable, Western European sources of very good quality and conform to private and g
whoever the engineer authorizes in witting prior to processing or implementation, and all forms are formally delivered to hi
4- The contractor must employ provisional engineers to supervise the work.
5- The contractor must take measures to ensure the safety of the neighboring areas of work (in facilities, services, etc.) and
6- The contractor must remove the rubble outside the site boundaries and in the areas permitted by the Baghdad Municipalit
municipalities in the case that the school is in the governorates.
7- The contractor must provide catalogs for the equipments that will be used in the work according to specifications in B.O.
8- The contractor must submit the (Shop Drawing) for all the necessary works items, according to the direction of the engin
implementation.
9- The brick which is using for sub structure masonry works under damp proof layer ( The works adjacent to soil) should be
damp proof layer should be type (B) for walls and partitions.
10- The sub - base which is using in backfilling works under foundations, floors, walkway floors, stairs on earth, roads and
paragraph.
11- All the steel work should be painted by one layer of anti-corrosion paint conformable to specifications before fixing and
12- The contactor must supply (As Built Drawing) after completion of the work and it must signed and approved officially
13- The specification of B.O.Q and specifications mentioned on the drawings are reliable and the general technical specifica
considered to be complementary in the absence of mention of the material or paragraph in special specifications.
14- All the quantities listed in B.O.Q. are estimative quantities according to design drawings and site survey and based on u
15- The uork shall be carried out in accordance with the detailed plans and estimation B.O.Q.
16- In the elements which are adjacent to the soil, the contractor should use sulfate resisting cement.
Item
P1
1
a

b
c

d
e

b
c
d

a
b
c
d

c
d
e

f
g
h

b
c

a
b
c
d
e

f
g

a
b
c
d

a
b
c
d
e

f
g

a
a

a
b
c
d
e
f

a
b
c

a
b

d
a

c
a
b

d
e

c
d

c
d
e

a
b

c
d

a
2

1-1

1-2

2-1

2-2
2-3

2-4

2-5

3-1

3-2

4-1

4-2

4-3

4-4

4-5
4-6

5-1

5-2

5-3

5-4

5-5

5-6

1
2

6
7

4
1

1-

2-

3-

4-

5-

P2
a

e
a

b
c
d
e

a
b
c
d

e
f
g

a
b

c
d

e
f

a
b
c
d

a
a
b

a
b
c

a
b

d
e

b
c

b
c

e
f

c
d

a
b

c
d

b
c

a
b
c

a
b
a

a
b

d
e

b
c

a
a

c
a

a
b
c

b
c

c
a

P3
First
1
2

2-1

4-1

4-2

5
5-1

5-2
5-3

5-4

Second
1

7
8

10

11

12

13

Third
1

3
4

Fourth
1

10

11
12

P4
1
1
a

2
1

4
3
1

4
1

P5
1

1-1
a
b
1-2

1-3

1-4
MINISTRY OF CONSTRUCTION,HOUSING AND PUBLIC MUNICIPALITIES NATIONAL CENTER FO
BILL OF QUANTIYIES
FOR STRUCTURAL, ARCHITECTURAL AND SERVICES WORKS
Typical School Buildings Project(Districts & Sub- Districts) TYPE NO (4
SECONDARY SCHOOL (18) CLASSES

ontents:-
Intermediate Or Secondary School (18) Classes works/Type No (4)
Site Works

MINISTRY OF CONSTRUCTION,HOUSING AND PUBLIC MUNICIPALITIES NATIONAL CENTER FO


BILL OF QUANTIYIES
FOR STRUCTURAL, ARCHITECTURAL AND SERVICES WORKS
Typical School Buildings Project(Districts & Sub- Districts) TYPE NO (4
SECONDARY SCHOOL (18) CLASSES SCHOOL BUILDINGS

ontents:-
Bill of Quantities for Structural and Architectural Works
Bill of Quantities for Sanitary Works
Bill of Quantities for Electrical Works
Bill of Quantities for Mechanical Works

ENERAL NOTES
All the items in B.O.Q. consist of supplying and transporting materials, working and fixing, inspection and operation according to the
riting and the technical specifications.
The B.O.Q do not include the furnishing works and the responsibility for these works falls on the shoulders of the beneficiary which it
All materials used are from sober, reliable, Western European sources of very good quality and conform to private and general technic
hoever the engineer authorizes in witting prior to processing or implementation, and all forms are formally delivered to him and the app
The contractor must employ provisional engineers to supervise the work.
The contractor must take measures to ensure the safety of the neighboring areas of work (in facilities, services, etc.) and not to disrupt
The contractor must remove the rubble outside the site boundaries and in the areas permitted by the Baghdad Municipality in case that
unicipalities in the case that the school is in the governorates.
The contractor must provide catalogs for the equipments that will be used in the work according to specifications in B.O.Q for all engi
The contractor must submit the (Shop Drawing) for all the necessary works items, according to the direction of the engineer or whoeve
mplementation.
The brick which is using for sub structure masonry works under damp proof layer ( The works adjacent to soil) should be type (A), the
amp proof layer should be type (B) for walls and partitions.
0- The sub - base which is using in backfilling works under foundations, floors, walkway floors, stairs on earth, roads and car parking sh
aragraph.
1- All the steel work should be painted by one layer of anti-corrosion paint conformable to specifications before fixing and another laye
2- The contactor must supply (As Built Drawing) after completion of the work and it must signed and approved officially from resident
3- The specification of B.O.Q and specifications mentioned on the drawings are reliable and the general technical specifications issued b
onsidered to be complementary in the absence of mention of the material or paragraph in special specifications.
4- All the quantities listed in B.O.Q. are estimative quantities according to design drawings and site survey and based on unified stander
5- The uork shall be carried out in accordance with the detailed plans and estimation B.O.Q.
6- In the elements which are adjacent to the soil, the contractor should use sulfate resisting cement.
Description
SCHOOL BUILDING
STRUCTURAL AND ARCHITECTUAL WORKS
Prelimina & Preparation Works
NOTES:
1- The quantities for these B.O.Q. and the works related to foundation designs and site designs for all engineering specialtie
estimative quantities made on the basis of hypothetica l foundation designs as they have been calculated on the basis of a so
strength of 8 ton/ m2 , and the necessary adjustments must be made to them according to the soil m vest1gat1o ns and exa
be implemented instead of the default principles mentioned in the typical design, as well as the case with regard to the site a
hypothetical design site that will also be modified later after the shape and dimensions of the plot of land allocated to the pr
provided that it does not affect the character of the orig in al design (typical) of the school building and all these actions tak
obtaining the approval of the employer for approval before implementation.
2-We considered that the natural ground level N.G.L=0.3 after skimming process, to calculate the earth works quantities wh
adjustment to soilofunder
3-The quantities dump
clearing andproofing layer
grabb ing according
, Leveling andtoalignment
what is proven
worksinwhich
the design drawings.
is written down in the B.O.Q. of School B
calculated for the whole site.
4-All items for preparing the typica l design for schools, conducting site surveys for the project site , conducting soil investi
project site, have been fixed in the B.O.Q. as shown below, and all of them are done after signing the project implementatio
each site separately.
5-The B.O.Q do not include the furnishing works and the responsibility for these works falls on the shoulders of the benefic
it determined later.
Preparation Works
General Notes:
Preparation Works takes place after signing the executive contract for the project, and it is one of the obligations and duties
implementation agency (the contractor) and the amounts are paid by it
a-Payment of fees for preparing the typical design draw in g fo r the sc hool a nd duly paid in the name of Natio nal Center
ring Consultin g or whoever le ga lly repla ces it within (7) days from the date of sign ing the project impleme nta tion cont
exchange fo r provid ing the beneficiary with the following:-
●Typical drawings fo r all enginee rin g s pecialties, with a suitable drawing scale3 - 3 copies (one colored + two black & w
●A compact disc (CD) of the above design drawings in (PDF) format (it is complete done by National center for en ineerin
not priced by contractor.

b-Conducting site surveys, preparing and submitting site survey plans for the project, preparing and presenting the site pla
with the plo t of land allocated to the project, provided that it d oes not affect the character of the origina l (typical) de s i
conducting soil investigatio ns fo r the projec t site a nd submi tting the necessary report in this way throug h the implement
pits wi th a number not less than (3) three with a depth of (15-20) meter to be determined by the con sultin g engi nee r, and
thru co ntrac ting with an officially approved and discreet consultin g office and preparing and submi tting new design d ra
found ations of buildings and annexes, including civil engineering and site works, and placin g so il t reatment s in case
needed for the projec t and in lig ht of the res ults o f th e tes ts and the report of soi l investigations and design loads of the
adopting them in implementations. The defa ult mentioned in the typical des ign and obtainin g the approval of the employ
before imple mentatio n the work includes mak ing all the modifications requested by the consulting enginee r and provid
with the design accounts fo r all the sp eciali zation s necessa ry for his approval the i:;eneral secretariat of a a roach
rovincial councils of the ur ose of rovidin us with labora tor tests for school sites and for each school se a ra tel a
providing as with laboratory surveys

c-Conducting an audit of the site plan, site services works desig ns and foundation desig n provided by the contractor that h
prepared in acco rdan ce with paragraph (b) above and fixing his obse rvations thereon for the purpose of making the ame
the co nsulta nt engine er designing the work under paragraph (b) abov e though contracting with the nationa l Ce nter of E
Consult ing and paying th e center an amount this paragraph when comple ting his auth entic ati on/ it is done bv Nationa
enineerin
Earth Works
Clearing and grabbing, Leveling the surface area and alignment works for the whole site.
Excavation work in accordance with technical specifications and construction plans, including the work of filling th
foundations with the same soil resulting from excavation, clean and suitable for backfilling, the work also including
compactions to the natural ground level (N.G.L.) and assigning the foundations sides in case they are needed.
-For Strips Foundations
Depth between (1.5-3) m
-For Separated Foundations
Depth between (1.5-3) m
-For Stairs on Earth Foundations
Depth not more than (0.5) m
-For Ramps Foundations
Depth not more than (0.5) m
-For Walkway Floors
Depth not more than (0.5) m
-For the internal garden
Depth not more than (0.5) m
Backfilling with clean soil empty from organic materials) as a layers not more than thickness (250) mm for each layer, the
including a good compaction (90%) as per drawings, consultant engineer's directions & technical specifications
-For Floors
To reach the required level for drawing
Backfilling with clean clay empty from impurities and suitable for agriculture , the work include leveling according to the
and making watering channel as per drawings. Consultant engineer's directions & technical specification
-For internal garden with Thickness not less than 300 mm
Backfilling with sub-base materials type (B) as a layers with thickness (250) mm for each layer, the work shall be inclu
and good compaction (95%) as per drawings, consultant engineer's directions & technical specifications
-For Strips Foundations
Thickness 500 mm
-For Separated Foundations
Thickness 500 mm
-For Floors
Thickness 150 mm
-For Walkway floor
Thickness 150 mm
-For Stairs on Earth
Thickness 150 mm
-For Ramps
Thickness 150 mm
Misalliance Items
Termite treatment for foundation's excavation , foundation's backfilling and floor's backfilling , provided that the type of
used, its specifications established by the manufacturer and the method of its use shall be submitted for approval by the en
using it according to the drawings & technical specifications
Dewatering of ground water collected by pumps and as per consultant engineer's directions and technical specifications
Items)
Concrete Works
Reinforced concrete using one layer of B.R.C No 63, compressive strength (25 N/mm2, cube test, 28 days) using sulfhte res
cement, the work shall be including formwork, steel reinforcement work and expansion Joints work as per drawings, consul
engineer's directions & technical specifications
-For Floors
Thickness l00 mm
-For Floors Under Masonry Brick Partitions
Thickness 250 mm
-For Stairs on Earth with its beams
-For Walkway Floors(Including Making The Required Slope)
Thickness 100 mm (Fair Face)
-For Ramps (Slope) with its Beams
Thickness 100 mm (Broom Finish)
Preparing materials and make the curbstones paving mold dimension (150x300x1000) mmtype (D/20) the work shall be inc
excavation and preparation and making a layer of non-reinforced concrete for base and back type (DY/20) and cement mort
drawings, chapter (B8,R11A,R11 table B8/5) of the specifications of roads and bridges and their modifications
Laying One layer of agricultural nylon sheet as per drawings and technical specifications
-For Floors
-For Stairs on Earth
-For Ramps
-For Walkway Floors
Miscellaneous Items
Installing expansion joints with all the Work Needed To Complete Of filling material & covering as per drawings, consulta
directions & technical specifications
Refilling the joints between the external walls and walk way floors with mastic materials as per drawings, consultant engine
directions & teclinical specifications
Concrete Works
Non-reinforced concrete (screed concrete) compressive strength (15 N/mm2, cube test. 28 days) using sulfete resisting cem
shail be including formwork as per drawings, consultant engineer's directions & technical specifications
-For Strips Foundations
Thickness 50 mm
-For separate Foundations
Thickness 50 mm
Non-reinforced concrete (blinding concrete) compressive strength (15 N/mm,cube test, 28 days) using sulfate resisting ce
work shall be including formwork as per drawings, consultant engineer's directions & technical specifications
-For Strips Foundations
Thickness 100 mm
-For separate Foundations
Thickness 100 mm
Reinforced concrete , compressive strength (30 N/mm2 cube test, 28 days) using sulfate resisting cement, the work shall be
fbnnwork, steel reinforcement work as per drawings, consultant engineer's directions & technical specifications.
-For Strips Foundations
Thickness 450 mm
-For Strips Foundations
Thickness 500 mm
-For separate Foundations
Thickness 500 mm
-For Columns Adjacent To Soil
-For Walls Adjacent To Soil (Stairs Walls) Thickness 300 mm
Masonry Works
Built with brick type (A) and cement mortar with mixing ratio (1:3) using sulfate resisting cement as per drawings, consult
directions & technical specifications
-For Walls Adjacent To Soil
Width 240 mm
Width 360 mm
Width 480 mm
Rendering with cement mortar with mixing ratio (1:3) using sulfate resisting cement as per drawings, consultant engineer's
technical specifications.
-For Walls Adjacent To Soil from both side
Laying and painting with three layers of protective layer as per drawings, consultant engineer's directions & technical spec
-Under Foundations
-For Foundations Tops & Sides (Strips and separate) , Walls And Columns Adjacent To Soil
Concrete Works
Non-reinforced concrete, compressive strength (25 N/mm2, cube test, 28 days) using sulfate resisting cement, the work sha
including formwork and mixing water proofing materials (sika chemical material) as per manufacturer company instruction
consultant engineer's directions & technical specification.
For Dump Proof Layer D.P.C.
Dimension 120x150 mm
Dimension 240x150 mm
Dimension 360x 150 mm
Dimension 480x150 mm
Reinforced concrete, compressive strength (30 N/mm2. cube test, 28 days) work shall be including formwork and steel rein
work as per drawings, consultant engineer's directions & technical specifications
For Walls (Under external windows)
Section dimension 360x300 mm
Reinforced concrete, compressive strength (25 N/mm 2, cube test, 28 days) work shall be including formwork and steel reinf
work as per drawings, consultant engineer's directions & technical specifications.
For Lintels
For Beams
Masonry Works
Built with brick type (B) and cement mortar with mixing ratio (1:3) as per drawings, consultant engineers directions & tech
specifications.
-For Walls
Thickness 120 mm
Thickness 240 mm
Thickness 360 mm
Thickness 480 mm
Price different to make crumbs in brick work as per drawings, consultant engineer's directions & technical specifications
-For Walls
Miscellaneous Items
Installing expansion joints with all the Work Needed To Complete Of filling material & covering as per drawings, consulta
directions & technical specifications
Concrete Works
Reiriforced concrete, compressive strength (30 N/mm , cube test, 28 days) work shall be including formwork and steel reinf
work as per drawings, consultant engineer's directions & technical specifications
For Floors&Ceilings
Thickness 180 mm
-For Beams Attached to Floors & Ceilings
-For Inverted Beams Attached to Floors & Ceilings
-For Fenders
For Parapets
Thickness 150 mm
For Parapets
Thickness 200 mm
-For Expansion Joint (In Roof) , width (368) mm & thickness between (100-120) mm
Miscellaneous Items
Installing expansion joints with all the Work Needed To Complete Of filling material & covering as per drawings, consulta
directions & technical specifications.
Concrete Works
Reinforced concrete, compressive strength (30 N/mm . cube test, 28 days) work shall be including formwork and steel rein
work as per drawings, consultant engineer's directions & technical specifications.
-For Stairs Landing&annex beams
Metal Works
Cat ladder of steel square hollow tubes section dimensions (50x50) mm and thickness (1.8) mm with steps of steel square h
section dimensions (25x25) mm and thickness (1.5) mm fixing each (300) mm, at the height of Cat ladder the work shall be
fixing accessories with the waEs of steel tubes, steel plates 、 bolts and welding 、 painting with one layer of red led mater
Javers of oil paint as per drawings, consultant engineer's directions & technical specifications.
-For Cat Ladder Width 700 mm and vertical height 4400 mm
Concrete Works
Reinforced concrete , compressive strength (30 N/mm 2, cube test, 28 days) , works shall be including all formwork and ste
reinforcement work with all fixing works between concretes columnsand brick walls by using steel plate of dimensions (PL
mmfixed each (600) mm upon wall height as per drawings, consultant engineer's directions & technical
specifications .
For Columns
Miscellaneous Items
Installing expansion joints with all the Work Needed To Complete Of filling material & covering as per drawings, consulta
directions & technical specifications
-For Columns
Metal Works
Aluminum windows with frame thickness (2) mm for both of them the practicable section must be good manufacture with t
insulation , the pilling up of sections must be done by pressing wav without bolts (colors and sections for frame specify by a
consultant engineer later). The work shall be includes installing an steel sub frame during construction process also includes
accessories hinges, handles, single transparent , thickness (6) mm and the work also include fly mesh for movable leafs & th
filling material between the frame and wall as per drawings, consultant engineer's directions & technical specifications.
-For Windows
Type W1 Dimension 1800 x 1500mm
Type W2Dimension 2400 x 1500mm
Type W3Dimension 1200 x 1500 mm
Type W4 Dimension 600 x 600 mm
Type W5 Dimension 2400 x 8950 mm
Type W7 Dimension 3600 x 1500 mm
Aluminum Door- Window with frame thickness (2) mm for both of them the practicable section must be good manufacture
insulation ,the pilling up of sections must be done by pressing way without bolts (colors and sections for frame specify by a
consultant engineer later). The work shall be includes installing an steel sub frame during construction process also includes
accessories hinges, handles. locks from foreign well-known manufacture, door stopper single transparent glass thickness (6)
work also include the flexible filling material between the frame and wall as per drawings, consultant engineer's directions &
specifications
Aluminum Door- Window
Type DW1 Dimension 7650 x 2400 mm With Double Door Dimension 2400 x 2400 mm / No.l &Windows Dimension 265
mm / No.2
Type DW1 Dimension 3575 x 2400 mm With Door Dimension 1000 x 2400 mm / No.l &Windows Dimension 2575 x 2250
Type DW1 Dimension 1800x 6550 mm With Double Door Dimension 1800 x 2400 mm / No.l &Windows Dimension 1800
No.1
Steel doors complete with frame and pressed by steel plate gauge 16 from both sides, installing an steel sub frame during co
process, painting with one layer of red led material and three layer of oil paint with all fixing accessories, locks from fore
known manufacture, door stopper ,hinges, handles as per drawings, consultant engineer's directions & technical specificatio
-For Single Doors
Type D6 Dimension 1000x2100 mm
with leave a space below the door a height of 300mm
Type D11 Dimension 600x800 mm (for shafts)
-For Double Door
Type D2 Dimension 2000x2400 mm
with (louvers) Dimension 300 x 200 mm
Plastic Works
Plastic doors (P.V.C.) complete with frame with (the practicable section must be good manufacture with thermal insulation
be specify by architectural consultant engineer later).The work includes installing an steel sub frame during construction pr
fixing accessories, hinges, handles, locks from foreign well-known manufacture, door stopper & also the flexible filling ma
between the frame and wall as per drawings, consultant engineer's directions & technical specifications
For Folded windows
Type W6 Dimension 1800 x 1500 mm
Plastic doors (P.V.C.) complete with frame with (the practicable section must be good manufacture with thermal insulation
be specify bv architectural consultant engineer later).The work includes installing an steel sub frame during constructionpro
fixing accessories、hinges, handles, locks from foreign well-known manufacture. door stopper the work a
拉 ying a space below the door a height of (50) mm & also includes fixable filling material between the f
wall as per drawings 、consultant engineer's directions & technical specifications.
- Single Doors
Type D4 Dimension 800 x 2100 mm
Wooden Works
Wooden doors with jawi frame of section(300x75)mm, the leafs consist of white wood frames covering by two layer of woo
sheet ,the first one from normal wooden sheet with thickness of (4)mm the second one from teak wood sheet with thickness
two faces,the work shall be include painting by three layer of spertodamalok and all fixing accessories, locks from foreign w
manufacture, hinges, handles, door stopper, the work also include covering the jioints between the attachment zone of door
walls by a strips of teak wood with width(100)mm& thickness(1.8)mm as per drawings. consultant engineer's directions &
specifications
- Single Doors
Type Dl Dimension l 000 x 2400 mm
with transparent glass thickness 6 mm with height 300 mm up door within total height for door
Type D3 Dimension 1000 x 2400 mm
with transparent glass thickness 6 mm with height 300 mm up door within total height for door and (louver) Dimension 500
Type D10 Dimension 1000 x 2400 mm
with transparent glass thickness 6 mm with height 300 mm up door within total height for door and (louver) Dimension 400
-For Double Doors
Type D5 Dimension 1800 x 2400 mm with ornamented
Metal Works
Handrail of steels square tubes section dimension (50x50) mm with middle section from teak wood width (150) mm thickne
and handles from teak wood section dimension (75x50) mm fixed up the steel tubes by steel plate width (60) mm thickness
bolts the work include all fixing accessories with concrete floors for stairs and landing from steel plate width (70) mm & th
(5)mm and bolt and its include painting with one layer of red led material , three layers of oil paint for metal parts & pain
three layer of spertodamalok for wooden parts and all the work needed to complete as per drawings, consultant engineer's d
technical specifications.
Stairs Handrail
Main stair with height 900 mm
Handrail of steel square tubes section dimension (50x50) mm with handles from teak wood section dimension (75x50) mm
steel tubes by steel plate width (60) mm thickness (5) mm and bolts the work include all fixing accessories with concrete flo
and landing from steel plate width (70) mm & thickness (5)mm and bolt
and its include painting with one layer of red led material 、 three layers of oil paint for metal parts & painting with three l
spertodamalok for wooden parts and all the work needed to complete as per drawings, consultant engineer's directions & tec
specifications.
- Stairs Handrail
Service stairs with height 900 mm
Wooden Work
Handles of teak wood fixed on the wall consisting of steel bars diameter (20) mm appears as (L) letter fixed on to the wall b
plants section diameter (50x100) mm and bolts each (500) mm and along the length of the wall with top handles from teak w
dimension (75x75) mm the work include installing with teak wood thickness (50)mm and quantity (0.2) ㎡ /M.L , the w
include painting with one layer of red led material . three layers of oil paint for metal parts & painting with three layers of s
for wooden parts and all the work needed to complete as per drawings, consultant engineer's directions & technical specific
Wooden Handles
Suspended ceiling of gypsum board , thickness(12) mm 、 the work shall be including all suspended metal structures with a
accessories and joints treatments between gypsum boards by using plastic mesh layer then plastering (talas) with suitable go
materials as per drawings. consultant engineer's directions & technical specification.
-For Horizontal & Vertical Ceilings
Suspended ceiling of metal strips the work shall be including all suspended metal structures with all fixing accessories as pe
drawings 、 consultant engineer's directions & technical specifications
-For Horizontal Ceilings
Suspended ceiling of metal Tiles Dimensions (600 x 600) mm the work shall be including all suspended metal structures wi
accessories as per drawings, consultant engineer's directions & technical speciflcations
-For Horizontal Ceilings
Smooth cement plastering with mixing ratio (1:3), the work shall be including leveling by using vertical rulers as per drawin
consultant engineer's directions & technical specifications
-For Walls
-For Parapets From Inside
Smooth cement plastering with mixing ratio (1:3), as per drawings, consultant engineer's directions & technical specificatio
-For External Ceiling
Painting with Matt Aclyric paint with a good quality, resistance the weather condition, washable, three layers, the first layer
layer and two layer of finishing paint upon it in accordance of the manufacturerand as per drawings, consultant engineer's d
technical specifications
-For Walls
-For External Ceiling
Price different
Price different to make ornamented cuneiform letter in cement elevations and all the work needed to complete as
consultant engineer's directions & technical specifications.
Installing marble skirting of thickness (20) mm by cement mortar with mixing ratio (1:3) the work includes filling joints wi
cement as per drawines, consultant engineer's directions & technical specifications.
For Skirting(light color)
Height 150 mm
Suspended glass facades (curtain wall double glazed) with hidden aluminum sections the work shall be include (reses) whic
of rubber sections to ensure sound and thermal insulation when opening and closing , the facades consist of tow layers of gl
external layer is tinted glass thickness (6) mm and the internal layer is transparent uelatin glass thickness (6) mm with a gap
between them which is filling by argon gases & includes fixing the two layers of glass on the aluminum frame and the glass
manufactured according to the measurement taken from the side and difference in dimension of manufacturing pieces bears
cost also include all suspended steel structures from aluminum designs to carry glass weight in this type of covering and a n
movable window location (which are determined architectural consultant engineer during the execution process later and al
needed to complete as per drawings, consultant engineer's directions & technical specifications.
(the contractor submits shop drawing for all covering work and design calculations for them and also submit samples of gla
sections used to the consultant engineer to obtain approval before starting work.)
-For Elevations Walls
Steel space frame which is consist of steel square section , the work include all of the fixing accessories painting with one la
led material, three layers of oil paint and all the work needed to complete as per drawings, consultant engineer's directions &
specifications.
(the contractor submits shop drawing for the aforementioned works and design calculations for them to the consultant engin
approval before starting work)
Steel space frame
Top view (90) M2
Steel square hollow tubes , the work include painting with one layer of red led material three layers of oil paint and all fixin
from bolts & welding and all the work needed to complete as per drawings, consultant engineer's directions & technical spe
Steel Tubes
Section demotions*(50X50) mm
Smooth cement plastering with mixing ratio (1:3), the work shall be including leveling by using vertical rulers as per drawin
consultant engineer's directions & technical specifications
-For Walls
Juss plasterine, the work shall be including layer of gypsum mokhammer , leveling by using vertical rulers and all of steel
drawings, consultant engineer's directions & technical specifications
-For Walls
Painting with plastic paint with a good quality. resistance the weather condition, washable, three layers, the first layer is a b
and two layer of finishing paint upon it in accordance of the manufacturer and as per drawings, consultant engineer's directi
technical specifications
-For Walls
Painting with (Matt Acrylic paint Resistant to chemicals materials) with a good quality, resistance the weather condition, w
layers, the first layer is a bases layer and two layer of finishing paint upon it in accordance of the manufacturerand as per dr
consultant engineer's directions & technical specifications
-For Walls
Painting with oil paint with three layer of finishing paint as per drawings, consultant engineer's directions & technical speci
-For Walls
Covering by ceramic tiles of dimensions (300x600) mm and cement mortar of mixing ratio(1:3), the work include filling jo
white cement, also include all metal angle for comer and around windows and door opining as per drawings, consultant eng
directions & technical specifications
-For Walls
Installing Porcelain tiles, light color. dimensions (600x600) mm and thickness (12) mm and cement mortar with mixing rati
work shall be including Riling joints with white cement as per drawings, consultant engineer's directions & technical specif
For Floors
Installing Porcelain skirtins of thickness (12) mm and cement mortar with mixing ratio (1:3) the work shall be including fil
with white cement as per drawings, consultant engineer's directions & technical specifications.
For Skirting(light color)
Threshold marble of thickness (20) mm and width (300,200.150) mm and cement mortar with mixing ratio (1:3) and all the
to complete as per drawings, consultant engineer's directions & technical specifications.
Threshold Marble (up the concrete fenders) Width 150 mm
Width 200 mm
Width 300 mm
Laying two layers of fitted carpet of thickness (10) mm the work shall be including non-reinforcement concrete layer (scree
under them of compressive strength (15N/mm 2 pingfanghaomi , cube test , 28 days) of thickness (50) mm and all adhesive m
fixing as per drawings, consultant engineer's directions & technical specifications
-For Floors
Laying a layer of epoxy material thickness (2) mm, the work shall be including non・reinforcement concrete layer (screed
under them of compressive strength (15N/mm 2, cube test , 28 days) of thickness (50 ) mm as per drawings, consultant engin
directions & technical specification
-For Floors

Epoxy material skirting of thickness ⑵ mm as per drawings, consultant engineer's directions & technical Speciflcations

For Skirting
Height 150 mm
Installing by non- slip ceramic tiles of dimensions (300x300) mm and cement mortar with mixing ratio (1:3), the work shal
laying one layer of water proofing bitumen for floor under the ceramic and walls with height (300) mm on walls and filling
white cement as per drawings, consultant engineer's directions & technical specifications -For Floors
-For Floors
Installing by ceramic Tiles resistant to chemicals of dimensions (300x300) mm and cement mortar with mixing ratio (1:3),
shall be include laying one layer of water proofing bitumen for floor under the ceramic and walls with height (300) mm on
filling joints with white cement as per drawings, consultant engineer's directions & technical specifications -For Floors
-For Floors
Installing ceramic skirting resistant to chemicals of dimensions (300x300) mm and cement mortar with mixing ratio (1:3) a
drawings, consultant engineer's directions & technical specifications
For Skirting
Height 100 mm
Installing teak wood skirting the work shall be including painting with spertodamalok material three layers and all fixing ac
per drawings, consultant engineer's directions & technical specifications.
For Skirting
Height 270 mm
Installing marble pieces thickness (30) mm with a round edge and cement mortar of mixing ratio (1:3), the work shall be inc
filling joints with white cement a as per drawings, consultant engineer's directions & technical specifications
-For Stairs ( Stairs Trades)
Installins by marble nieces thickness (20) mm and cement mortar of mixing ratio (1:3), the work shall be including filling jo
white cement a as per drawings, consultant engineer's directions & technical specifications
-For Stairs ( Stairs Risers)
Installing marble pieces of thickness (30) mm and cement mortar of mixing ratio (1:3), the work shall be including filling jo
white cement a as per drawings, consultant engineer's directions & technical specifications
-For Landing
Smooth cement plastering with mixing ratio (1:3),as per drawings, consultant engineer's directions & technical specificati
-For Bottom, Sides Zone Of Stairs And Landing
Juss plastering, the work shail be including layer of gypsum mokhammer a as per drawings, consultant engineer's directions
specifications
-For Bottom, Sides Zone Of Stairs And Landing
Painting with Matt Aclyric paint with a good quality, resistance the weather condition, washable, three layers, the first layer
layer and two layer of finishing paint upon it in accordance of the manufacturerand as per drawings, consultant engineer's d
technical specifications
-For Bottom, Sides Zone Of Stairs And Landing
Smooth cement plastering with mixing ratio (1:3) a as per drawings, consultant engineer's directions & technical specificati
-For Ceilings
Juss plastering,the work shall be including layer of gypsum mokhammer a as per drawings, consultant engineer's direction
specifications
-For Ceilings
Painting with Matt Aclyric paint with a good quality, resistance the weather condition, washable, three layers, the first layer
layer and two layer of finishing paint upon it in accordance of the manufacturerand as per drawings, consultant engineer's d
technical specifications
-For Ceilings
For gypsum suspended ceilings
Horizontal & Vertical
Painting with oil paint with three layer of finishing paint as per drawings, consultant engineer's directions & technical speci
-For Ceilings
Laying layer of prime coat, non- reinforcement concrete slopins layer, compressive strength (15N/mm 2, cube test, 28 days),
between (80-130) mmto obtain the required slope ( slope 1 %)towered the gutter, the work shall be include expansion joint
filling the joints by mastic or any filler, flexible and moisture wicking material with cauterization, laying a layer of water pr
thickness (20) mm , layer of thermal insulation thickness (50) mm , layer of clean sand thickness (20) mm, pre- cast concre
dimension (800x800x40) mm , the work include also extending the work of anti-humiditv material to the height of (50) mm
height point of roofing for beams & parapets, with joints filled with mastic and cauterization, non-reinforced skirtins with c
strength (25N/mm2, cube test, 28 days) dimension (150x150) mm and all the work needed to complete as per drawings, con
engineer's directions & technical specifications.

-For Horizontal Roofs


Painting the concrete surface with water proofing materials type roof guard as a layers, the first layer is a primer then put th
layer of roof guard1the work consist laying a layer of fiber class on it and the third layer of roof gard2. the work shall be inc
cleaning the concrete surface from dust and other unwanted materials and repair of damaged area and repair cracks before s
work tas per manufacturer directions and making all the work needed to complete as per drawings, consultant engineer's dir
technical specifications
-For Horizontal Roofs
Metal Works
Covering For Maintenance Opining (Shafts) which is consists of hollow square columns from steel dimension (50x50) mm
covering by wire mesh and galvanized sheet no. 16 fixing the cover with beam concrete by steel angle the work include pai
one layer of red led material ,three layers of oil paint and all necessary fixing accessories from welding and metal plate and
drawings, consultant enginee's directions & technical speciflcations.
Covering For Maintenance Opining (Shafts)
(Top View)
Item
PRELIMINARY & PREPARATION WORKS (--) / Preparation Works
takes place after signing the executive contract for the project
EARTH WORKS (11)
FLOOR BEDS WORKS (13)
RETAINING WALL, FOUNDATIONS WORKS(16)
EXTERNAL AND INTERNAL WALLS WORKS (21& 22)
FLOOR GALLERIES WORKS AND CEILINGS WORKS (23 & 27)
STAIRS WORKS (24)
BUILDING FRAMS, OTHER PRIMARY ELEMENTS WORKS (28)
EXTERNAL AND INTERNALWINDOWS &DOORS WORKS (31&32)
SECONDARY ELEMENTS TO STAIRS (34)
SUSPENDED CEILINGS WORKS (35)
WALL FINISHES, EXTERNAL (41)
WALL FINISHES, INTERNAL (42)
FLOOR FINISHES (43)
STAIR FINISHES (44)
CEILING FINISHES (45)
ROOF FINISHES (47)
TOTAL AMOUNT CARRIED TO FINAL SUMMARYOF ARCHITECTURAL, STRUCTURAL ANDSERVICES WORK
SCHOOL BUILDING
NOTE: The B.O.Q do not include the furnishing works and the responsibility for these works falls on the shoulders of the b
which it determined later
TOTAL AMOUNT CARRIED TO FINAL SUMMARY OF ARCHITECTURAL & STRUCTURAL WORKS FOR S

BILL OF QUANTITY SANITARY WORKS


The price for the following items shall be for complete supply, install, and operation with all necessary accessories and anci
including controls and instrument as shown on schedules, drawings and specifications. All sanitary works and equipments s
from well known origin.
Drainage Works
U.P.V.C Pipes:
Supply, install and test U.P.V.C drainage pipes, ventilation, split drain &sleeves high pressure (6 bar) type of following diam
according to the manufactures instructions inside buildings, the price include excavation, back filling with sand (10cm arou
and concrete cover 10 cm conforming to B.S4660 for under-ground drainage pipes and B.S4514 for soil, ventilation. This w
fittings supports, hangers, clean-outs (floor & ceiling types) as shown on the drawings using solvent type joints with good q
tangent.
-U.P.V.C pipe (110) mm. dia.
-U.P.V.C pipe (50) mm. dia.
Gully traps:
Supply, install and test U.P.V.C gully traps with all connections as shown on the drawings, the trap should be surrounded by
thickness with water proofing materials for ground floor and gully traps in upper floors with all connections and hangers etc
on the drawings and specified by the Engineer. -110 mm dia. with brass chromium plated grating cover with hinged solid co
resisting cement of 15 cm
RAIN WATER WORKS :
RAIN WATER PIPES:
Supply, install & test U.P.V.C (8bar) rainwater pipes(vertical &horizontal inside buil.) high pressure type of following diam
according to the specification B.S.4514 instruction in side buildings. This will included all fiings support hangers,outlets, et
solvent type joints with good quality tangent &approved by an engineer.
-U.P.V.C pipe (110) mm. dia.
-U.P.V.C pipe (110) mm. dia.
-Supply,install and test cast iron domical rainwater outlet, made of cast iron body with combined flashing clamp and gravel
polyethylene dome,of following nominal internal diameter conforming to B.S The work shall include fixing, water proofing
cover with chain, also the work shall include connection with vertical rainwater pipes.
Rainwater outlet(100)mm.dia
Rainwater outlet(150)mm.dia
Ditto as item (1-1) above , but for handicapped cases provided with grab bar.
Supply, install ,test and executing reinforced concrete channel to drain rainwater using salt resistant cement at mixing ratio
pain all inemal sides by flancott three layers at least 5 micron thickness, the work include supply and fixing frame and cove
duty cast iron from good quality according to approved engineering. The channel shall be with a width (35)cm,and an initia
20)cm.and all other accessoris
Cold & Hot water suddIy:- Supply, install and test aluminum reinforced polypropylene water pipes (PN16) according to D
DIN 16962 or any approved specification for cold, and hot water pipes inside the building of following, and valve.the pipes
under pressure of no less than (10)bar or 150% of the operating whichever is greater for a period of (24)hours and is consid
acceptable after passing examination approved by consulting engineer ,This includes all fittings, valves, wherever needed o
branches, supports, and according to the internal diameters,etc.
-15 mm dia.
-20 mm dia.
-25 mm dia.
-32 mm dia.
Water suply work
GALVANIZED STEEL PIPES:
Supply, install and test galvanized steel welded pipes to B.S. 1387 heavy weight, installed, jointed, and tested complete with
steel fittings, accessories, supports, hangers using clamps with rubber inlay, threaded rods, sleeves, pipe marking, expansion
pipes are test under pressure of no less than (10)bar or 150% of the operating whichever is greater for a period of (24)hours
considered acceptable after passing examination approved by consulting engineer , This includes all fittings, valves, wherev
main lines branches, supports all as specified and shown on drawings
-25 mm dia.
Polvethvlene water tanks:
Supply, install and test water tanks of heat-resistant plastic and bacteria growth (polyethylene)from an approval origin, the p
all that is related of accessories tank such as pipes attaching connection to tank,maintenance float of 20mm dia,over flow pi
pipe20mm,gate valve,the price includes the preparation and erection of concrete bases from precast,before the completion o
flattening works,to be height of 15 cm,according to the approval of sanitary and civil plans
water tank size 1 m3
Sanitary Fixtures
European Water Closet :
Supply , install test White European water closet as shown in the drawings and as specified to approval to Engineer, consist
storage glazed vitreous china has(61iter) at least fron low type with seat and cover, fixing by bolt and connection to water b
chrome plating and nuts from chrome made with all necessary accessories.
Eastern Water Closet:
Supply, install & test eastern water closet as shown on the drawings & as specified to the approval of eng. With ahigh tank
plastic, a water pipe coming down from the tank of plastic, diameter of 32 mm,with a manual water hose with all necessary
Lavatory:
Supply, install and test white glazed vitreous china lavatory basin as shown in the drawings and as specified to the approval
with self contained overflow 15 mm cold and hot water supply mixer , drainage plug and chain waste. All exposed brass wo
chrome plated -Size (56 x 40) cm. The work shall include soap holder one towel holder, shelf, mirror, and all accessories.
Stainless Steel Sink:
Supply, install and test stainless steel sink in overall with outlet and over flow with 15mm. mixer for cold and hot water inle
bottle trap drain. The price includes fixing sink on counter as per approval of the Architect, of the following dimensions or
dimensions -single bowel, two wing Size (60x90) cm
Supply, install and test Lab sink in overall with outlet and over flow with 15mm. mixer for cold and hot water inlet, 40mm
drain. The price includes fixing sink on counter as per approval of the Architect, of the following dimensions or any approv
dimensions.
Electric water heater:
Supply, install and test electric water heater, vertical type, enamel coated tank, 25 mm Aluminum injected polyurethane ins
complete with all accessories and connection such nun return valve, isolating valves, automatic air vent, electric heater acce
without draining the water heater, titanium or magnesium anode, thermostat with safety cut-out, safety group, tundish in CP
indirect water discharge to drain, and accessories, all as specified and shown on drawings, with all electrical connections, w
220v, 50 Hz, A.C current.
-E.W.H of 50 lit, 1.5 kW
Fire fiehtine System
Fire fiehtine Network:
Supply, install and test galvanized steel pipes to B.S. 1387 heavy weight, installed, jointed, and tested complete with galvan
fittings, accessories, supports, hangers using clamps with rubber inlay, threaded rods, sleeves, pipe marking, expansion join
specified and shown on drawings.
-25 mm dia.

Excavation trenches in any kind of soil whatever nature & removal of pockets of soft material or loose rock from the bottom
excavation, placement & compaction of required backfill (after laying jointing & testing of pipe lines )&disposal of surplus
directed by the Engineer, supply of HDPE-PE100-PN16 Pipes (16Kg/cm2) working pressure, laying, jointing & testing the
trenches with a test pressure not less than_(10Kg/cm2 ) for not less than 6 hrs. The minimum height of pipe cover shall be (
main pipes from natural ground level & (60cm) for branches. The laying of pipes shall be done after placing sand & gravel
max. size filling in pockets from where soft material ...etc. has been removed & after placing (15cm) thickness sand & grav
pipes & (30cm) thickness above the pipes & all around. The work includes the construction of thrust blocks at every bends
connection & a protection for the pipe crossing under roads or other pipes. The work includes the testing & disinfections of
& site clearance.
-40 mm dia.
-50 mm dia.
Hose Reel Cabinet:
Supply, install and test fire hose cabinet, steel construction, wall recessed type, installed connected and tested complete incl
listed angle pressure regulating valve with locking pin device and field setting chart made from cast brass, 25mm diameter a
long rubber hose mounted on swinging reel, high impact plastic 6mm nozzle (fogstream type), steel door with identifying d
accessories all as specified and shown on drawings, of total dimensions (810x810 x240)mm , or any approved dimensions s
180° center pivot

Portable Fire Extinguishers:


Supply, install and test portable fire extinguishers having capacity of (4.5) Kg, each supported on wall hooks as specified. P
extinguisher; ABC dry chemical, 6kg capacity, type shall conform to B.S 3465 and CO2 type shall conform to B.S 3326, ste
body, with pressure indicator, reinforced hose and discharge horn, squeeze handle, wall mounted bracket, installed with tag
accessories, all as specified and shown on drawings .
CO2 type fire extinguisher
ABC type fire extinguisher
Air relief valves:
Air relief valves for feeding pipes Supply, install in position & test of air relief valve (25mm.dia) on high point on main pip
fire). The work shall be done according to drawing & specification or as directed by the engineer.
Supply, install and test water tap with base concrete to water supply feeding and shall be good quality made with all necessa
accessories.
TOTAL AMOUNT CARRIED TO FINAL SUMMARY OF ARCHITECTURAL & STRUCTURAL WORKS FOR S

BILL OF QUANTITY ELECTRICAL WORKS

Point wiring for lizhtinz , fan and socket outlet

Supply , install , test and commission following wiring points by means of PVC insulated, single core copper wire of size
indicated in the drawings and single line diagram of distribution boards inside heavy gauge 20mm PVC conduit and by usi
cable tray control switch(10A) wherever indicated in the drawings , socket outlets , earthling wire etc. as required :
a- light point
b- exhaust fan point
c- ceiling fan point
Lizhtiiie Fittings
Supply , install , test and commission lighting fittings with all accessories as indicated in the drawings as required :
a-lighting fitting(LED)ceiling mounted type,(lx38w) with(120x22)cm dimension,(Fl).
b-lighting fitting(LED)circular shape type,(lx28w) with(22)cm diameter, suitable for false ceilings with IP54,(F2).
c-lighting fitting(LED)circular shape ,wall mounted type,(1x28w) with(22)cm diameter,(F3-1).
d-Projector lighting fitting(LED) FLOOD LIGHT, (90w), with IP65, (F5).
Electrical bell point:-Supply , install, test and commission wall electrical bell point using (3x2.5)mm2 single copper wire th
ceiling embedded PVC pipes with all accessories as indicated in the drawings price include bell and bell push button
POINT WIRING FOR SCOKET OUTLETS
Supply, install, test and commission the following wiring points by means of pvc insulated, single stranded copper wires of
(3x4)mm2 inside heavy gauge 20cm pvc conduit complete with socket outlet and all accessories.
a- 3 pin 13 Amps socket outlet point.
b- 3 pin 13 Amps duplex socket.
c- 3 pin 15 Amps socket outlet point.
d- 32A switch with pilot lamp for air conditions.
e- 32A switch with pilot lamp for water heater ,weather proof type, with IP54.
Feeders and accessories
a-supply, install, test & commission PVC insulated PVC sheathed unarmored low tension copper cable (PVC/PVC) of size
in the drawings and below to be fixed on wall, over false ceiling , over cable tray clipped by suitable clips as required comp
connections from two sides by suitable cable terminals witch fixed by compressor as per specifications:
-(3x4)mm2
-(4x10+lx10)mm2
-(4x25+lx16)mm2
-(4x16)mm2+(lxl6)mm2
b-Supply and install perforated, galvanized steel horizontal cable tray(thickness not less than 2mm) including fixing to
above the false ceilings, as required with suitable supports with all accessories including bends, termination, etc. as required
-(10x30)cm
Main &Sub Main distribution boards
Supply install test and commission main and sub main distribution boards made of sheet steel of at least 2mm thick with pa
mounted , front and rare accessible double door and lock, dust and vermin proof, suitable for 500V, 3ph, 50HZ AC supply c
main incoming molded case circuit breaker and many outgoing M.C.C.B.(with noticing the short circuit current for each cir
including connections, lettering, and metering instruments, and protection instrument like protection against short circuit o
low and high voltage , phase failure , phase sequence etc. as indicated in the drawings as below :

-MDB
consist of:
-1 No.incoming (M.C.C.B)of rating (400A),3ph.
-3 ph,600A copper bus bar with neutral bars and earth/1 set.
-1 No.(3ph,200A) M.C.C.B.
-3 No.(3ph,80A) M.C.C.B.
-2 No.(3ph,60A) M.C.C.B.
-4 No.(3ph,40A) M.C.C.B.
-4 No.(3ph,30A) M.C.C.B.
-1 Set capacitor bank of capacity (4steps-100 KVAR)with all accessories.
-1 No. 400A KW/Hr. meter.
-1 No. voltmeter (0-500V).
-1 No. contactor 45A

SUB distribution board


Supply, install, test and commission dust & vermin proof steel distribution boards with door & lock to be fixed in the wall o
incoming MCCB or non automatic circuit breaker (N.A.C.B.) for circuit breakers below 100A and many outgoing automati
circuit breaker of ratings as per drawings of good quality types as require:
-12 line
-15 line
-18 line
-21 line
Internet system
a-Supply, install, connect ,test and commission internet ROUTER by using POE CAT6 cables drawn in separate heavy gaug
conduit or PVC trucks with cover to be connecter to the Main Router & all accessories as indicated in the drawing the price
and connect the router
b-Supply, install, test and commission internet Main Router size of 8 outlet POE with all requirement to complete the work
c-Supply, install , test ,commission and operate internet NANO POWER BEAM fixed on the roof and to be connected to th
Router & all accessories as indicated in the drawing

TOTAL AMOUNT CARRIED TO FINAL SUMMARY OF ARCHITECTURAL & STRUCTURAL WORKS FOR S

BILL OF QUANTITY MECHANICAL WORKS


School Building
The price for the following items shall be complete supply, install and operation with all necessary accessories and ancillary
including controls and instruments as shown on schedules, drawings and specifications
Exhaust fan, propeller wall mounted, low noise complete with pull cord and automatic shutter.
M3/HR
∅250 900
∅300 1300
Ceiling fans with a diameter of 140 cm, single-phase complete with a speed regulator, good quality. According to
specifications and the mechanical drawings.

UPVC plastic pipes for the drainage of condensate water for split units at a pressure of not less than 6 bar with all ne
accessoriesfor installationcomplete with elbows, tees, reducers .... etc. installed pipes under the level of finishing walls an
under the level of external wall covering, and connected to the nearest floor drain
Size (mm)
25mm∅

PVC plastic pipes, (SLEEVE PIPE) for the passage of insulated copper pipes, electric cable that connects between the o
indoor units for wall mounted & floor standing split units, with all necessary accessories for installation according to the
drawings and directions of the supervising engineer
size (mm)
80mm∅
100mm∅

UPVC Truncking pipe to be established on the interior walls for covering the copper tubes, electrical cables and the conde
pipes of the split units.
Dimensions (mm x mm)
80x80
100x100
FINAL SUMMARY of P1
For Structural and Architectural Works
Typical School Buildings Project(Districts & Sub-Districts) Intermediate Or Secondary School (18) Classes /Type No(4)
1- Structural and Architectural Works
2- Sanitary Works
3- Electrical Works
4- Mechanical Works
Total Amount Carried to The Final Summary of Structural, Architectural and Services Works for Site
Site works
1- Bathroom Building & Sanitary Services Room Works
NOTES:
1- The quantities for these B.O.Q. and the works related to foundation designs and site designs for all engineering sp
estimative quantities made on the basis of hypothetical foundation designs as they have been calculated on the b
bearing strength of 8 ton/ ㎡ , and the necessa ry adjustments must be made to them according to the soil mvest
examinations to be implemented instead of the defa ult principles mentioned in the typical design , as well as the case
the site as it is a hypnthetical design site that will also be modified later after the shape and dimensions of the plot of lan
the project, provided that it does not affect the character of the original design (typical) of the school building and all
take place after obtaining the approval of the employer for approval before implementation .
2- We considered that the natural ground leve l N.G.L= -0.3 after skimming process, to calculate the earth works quantit
adjustment to soil und er dump proofing layer according to what is proven in the design drawings.
3- The quantities of clearing and grabbing, Leveling and alignment works for guard building where calculated within
(clearing and grabbing , leveling the surface area and alignment works) which is fixed down in the B.O.Q. of School Build
4-All items for preparing the typical design for schools, conducting site surveys for the project site , conducting soil invest
project site, have been fixed in the B.O.Q. school building - prelimin ary and preparatio n works (- -)
5- The B.O.Q do not include the furnishing works and the responsibili ty for these works falls on the shoulder s of the bene
it determined later.
Earth Works
Excavation work in accordance with technical specifications and construction plans, including the work of filling th
foundations with the same soil resulting from excavation, clean and suitable for backfilling. the work also including
compactions to the natural ground level (N.G.L.) and assigning the foundations sides in case they are needed.
For Strips Foundations
Depth not more than (1.5-3) m
For Walkway Floors
Depth not more than (0.5) m
For Walkway Floors
Depth not more than (0.5) m
For Water Storage Tank Base Foundations
Depth not more than (1) m
Backfilling with sub-base materials tvpe (B) the work shall be including spraying and good compaction (9
drawings,consultant engineer's directions & technical specifications
For Strips Foundations
Thickness 500 mm
For Water Storage Tank Base Backfilling one layer
Thickness 250 mm
Backfilling with sub-base materials type (B), the work shall be including SQraying and good comQaction (
drawings,consultant engineer's directions & technical specifications
For Floors
Thickness 150 mm
For the walkway floors
Thickness 150 mm
For Ramps
Thickness 150 mm
Mialliances Items
Termite treatment for foundation's exca vation , foundation's backfilling and floor's backfilling , provided that the type of
used, its specifications established by the manufacturer and the method of its use shall be submitted for approval by the en
using it according to the drawings &technical speeifications
Dewatering of ground water collected by pumps and as per consultant engineer's directions and technical
(ProvisionalItems)
Concrete Works
Reinforced concrete using one layer of B.R.C No.63, compressive strength (25 N/mm² , cube test 28 days) u
resisting cement, the work shall be including formwork, steel reinforcement work and expansion Joints work as per drawin
engineer's directions & technical specifications
For floors
Thickness 100 mm
For floors under Masonry Brick Partitions
Thickness 250 mm
For Ramps (Slope) with its Beams
Thickness 100 mm (Broom Finish)
For Walkway Floors (Including Making The Required Slope)
Thickness 100 mm (fair face)
d Reinforced concrete using two layer of B.R.CNo.63, compressive strength (25 N/mm2, cube test, 28 days) using sulfate
cement, the work shall be including formwork, steel reinforcement work and expansion Joints work as per drawings, consul
engineer's directions & technical specifications
For floors
Thickness 200 mm
Preparing materials and make the kerbstone paving mold dimension (150x300x1000) mm type (D/20) the work shall
excavation and preparation and making a layer of non-rein forced concrete for base and back type (DY/20) and cement
drawings, chapter (B8,Rl lA,Rl 1 table B8/5) of the specifications of roads and bridges and their modifications
Reinforced concrete , compressive strength (30 N/mm 2. cube test, 28 days) using sulfate resisting cement, the work shal
formwork, steel reinforcement work as per drawings, consultant engineer's directions & technical specifications
For Pump Base
Thickness 500 mm
Metal Works
Metal section of Steel type (IPE-120) ,the work shall be including painting with one laver of red led material and three lay
with all fixing accessories with concrete beams for water storage base and all work needed to complete as per drawing
engineer's directions & technical specifications
For Steel Sections type IPE-120
Laying One layer of agricultural nylon sheet as per C236drawings and technical specifications
For floors
For Ramps
For Walkway Floors
Miscellaneous Items
Refilling the joints between the external walls and walk way floors with mastic materials as per drawings, consultant engine
directions &technical specifications
Concrete Works
Non-reinforced concrete (screed concrete) compressive strength (15 N/mm2, cube test, 28 days) using sulfate resisting
work shall be including formwork as per drawings,consultant engineer's directions & technical specifications
For Strips foundations
Thickness 50 mm
For Water Storage Tank Base
ThiGkness 50 mm
Non-reinforced concrete (blinding concrete) compressive strength (15 N/mm², cube test, 28 days) using sulfate resistin
work shall be including formwork as per drawings, consultant engineer's directions & technical specifications
For Strips foundations
Thickness 100 mm
For Water Storage Tank Base
Thickness 50 mm
Reinforced concrete , compressive strength (30 N/mm2, cube test, 28 davs) using sulfate resisting cement, the work shall
foemwork, steel reinforcement work as per drawings,consultant engineer's directions & technical specifications
For Strips Foundations
Thickness 450 mm
For Columns Adjacent To Soil
For Water Storage Tank Base with its inveited beams
Thickness 300 mm
Masonry Works
Built with brick type (A) and cement mortar with mixing ratio (1:3) using sulfate resisting cement as per drawings, consult
directions & technical specifications
For Walls Adjacent To Soil
Width240 mm
Rendering with cement mortar with mixmg ratio (1:3) using sulfate resisting cement as per drawings, consultant engineer's
technical specifications
For Walls Adjacent To Soil from both side
Laying and painting with three layers of protective layer as per drawings, consultant engineer's directions & technical s
Under Foundations
For Strip Foundations Tops &Sides, Water Storage Tank Base & Colunms Adjacent To Soil
Concrete Works
Non-reinforced concrete, compressive strength(25 N/mm2, cube test, 28 davs) using sulfate resisting cement, the work shal
form work and mixing water proofing materials (sika chemical material) as per manufacturer company instruction, drawin
engineer's directions & technical specification
For Dump Proof Layer D.P.C.
Dimension 120xl50 mm
Dimension 240x150 mm
Reinforced concrete, compressive strength (N/mm2 , cube test, 28 days) work shall be including formwork and steel
work as per drawings, consultant engineer's directions & technical specifications
-For. Lintels
-For Beams
Masonry Works
Built with brick type (B) and cement mortar with mixing ratio (1:3) as per drawings,consultant engineer's directions
specifications
For Walls
Thickness 120 mm
Thickness 240 mm
Metal Works
Cat ladder of steel square tubes hollow section dimensions (50x50) mm and thickness (1.8) mm with steps of steel square
section dimensions (25x25) mm and thickness (1.5) mm fixing each (300) mm, and at the height of Cat ladder the w
including all fixing accessories with the walls of steel tubes 、steel plates、bolts and welding painting with one la
material,three layers of oil paint as per drawings,consultant engineer'sdirections & technical specifications
For Cat Ladder
Width 700 mm and vertical height 4400 mm
Concrete Works
Reinforced concrete, compressive strength (30 N/mm² cube test. 28 davs) work shall be including formwork
reinforcement work as per drawings,consultant engineer's directions & technical specifications
-Ceilings
Thickness 180 mm
For Beams
For Interred Beams
For Parapets Thickness 150 mm
Concrete Works
Reinforced concrete , compressive strength (30 N/mm2, cube test, 28 days) , works shall be including all formw
reinforcement work with all fixing works between concretes columns and brick walls by using steel plate of dimensions (P
mm fixed each (600) mm upon wall height as per drawings, consultant engineer's directions & technical specifications
- For Columns
Metal Works
Aluminum windows with frame thickness (2) mm for both of them the practicable section must be good manufacture w
insulation , the pilling up of sections must be done bv pressing way without bolts (colors and sections for frame specify by
consultant engineer later).The work shall be includes installing steel sub fram during construction process also inclu
accessories hinges. handles.single transparent glass thickness (6) mm ,the work include fly mesh for movable leafs
filling material between the frame and wall as per drawings,consultant engineer's directions & tecnnical specifications
For Windows
Type W3Dimension1200 x1500 mm
Type W4Dimension 600 x 600 mm
Steel doors complete with frame and pressed bv steel late au e 16 from both sides installin an steel sub frame dur
construction process. painting with one layer of red led material and three la er of oil aint with all fixin accessor
from forei n well-known manufacture. door stopper ,hinges, handles as per drawings, consultant eng
directions & technical specifications
Srngle Doors
Type D8 Dimension 1000 x 2400 mm with louvers dimension 750 x600 mm
Type D9 Dimension 1100 x 2400 mm with louvers dimension 500 x200 mm
For Double Doors
Type D10 Dimension 2000 x 2400 mm with louvers dimension 300 x200 mm
Plastic Works
Plastic doors (P.V.C.) complete with frame with (the practicable section must be good manufacture with thermal insulatio
be specify by architectural consultant engineer later).The work includes installing an steel sub frame during constructio
fixing accessories, hinges,handles.dies loc ks from forei n well-known manufacture door sto er the work also include lea
below the door a height of (50) mm & also includes fixable fillin material between the frame and wall as per drawin
engineer's directions & technical specifications
- Single Doors
Type D5 Dimension 800 x 2100 mm
Metal Works
External Handrail of steel esquire tubes of steel square tube of different sizes ,consisting of steel square tube of secti
(50x50) mm each (500) mm and along the lengh of rails and horizontal tube of section dimension (50x50) mm each (20
height of handrail , handles from steel tubes section dimension (75x75) mm fixed above steel tubes, the work inclu
accessories with floors from steel late bolts and welding painting with one laver of red led material three layers of oil pa
all the work needed to complete as per drawings, consultant engineer's directions & technical specifications
External Handrail
with height 900 mm
Suspended ceiling of metal strips the work shall be including all suspended metal structures with all fixing acces
drawings,consultant engineer's directions & technical specifications
For Horizontal Ceilings
Smooth cement plastering with mixing ratio (1:3),work shall be including leveling by using yertical rulers as per drawin
engineer's directions & technical specifications
-For Walls
For Parapets From Inside
Smooth cement plasterin g with mixing ratio (1:3), as per drawings, consultant engineer's directions & technical specificatio
-For External Ceiling
painting with Matt Aclyric paint with a good quality, resistance the weather condition,washable three layers, the first
bases layer and two layer of finishing paint upon it in accordance of the manufacturerand as per drawings, consultant engine
directions & technical specifications
-For Walls
-For External Ceiling
Installing marble skirting of thickness (20) mm by cement mortar with mixing ratio (1:3) the work includes filling join
cement as per drawings, consultant engineer's directions & technical specifications
For Skirting (light color)
Height 150 mm
Smooth cement plastering with mixing ratio (1:3), the work shall be including leveling by using vertical rulers as
consultant engineer's directions & technical specifications
For Walls
Painting with oil paint with three layer of finishing paint as per drawings, consultant engineer's directions & technical speci
For Walls
Covering bv ceramic tiles of dimensions (300x600) mm and cement mortar of mixing ratio (1:3), the work include fillin
white cement, also include all metal angle for comer and around windows and door opining as per drawings, consult
directions & technical specifications
-For Walls
Laying a layer of egoxy material thickness (2)mm, the work shall be including non-reinforcement concrete layer (sc
under them of com11ressive strength (15N/mm² cube test , 28 days) of thickness (50) mm as Qer drawings, consult
directions & technical specification
-For Floors
Epoxy material skirting of thickness (2) mm as per drawings, consultant engineer's directions & technical specifications
For Skirting
Height 100 mm
Installing by non slig cerarmic tiles of dimensions (300x300) mm and cement mortar with mixing ratio (1:3},
be include laying one layer of water proofmg bitumen for floor under the ceramic and walls with height (300) mm on wa
joints with white cement as per drawings, consultant engineer's directions & technical specifications
-For Floors
Smooth Cement Plastering with mixing ratio(1:3) due to drawings,consultant engineer's directions & specification
-For Ceilings
painting with oil paint three layers as per drawings. consultant engineer's directions & technical specifications
-For Ceilings
ing layer of prime coat,non- reinforcement concrete slooing layer, compressive strength (15N/mm² , cube test、 28 day
between (80-130) mm to obtain the required slope ( slope l%) towered the gutter 气 the work shall be include expansion jo
filling the joints by mastic or any filler, flexible and moisture wicking material with cauterization, laving a laver of w
thickness (20) mm , layer of thermal insulation thickness (50) mm,layer of clean sand,pre cast concrete pieces
(800x800x40)mm, the work include also extendingthe work of anti-humidity material to the height of (50) mm for the he
roofing for beams&parapets,with ioints filled with mastic and cauterization. non-reinforced skirting with compressi
(25N/mm² , cube test, 28 days) dimension (150x150) mm and all the work needed to complete as per drawings consulta
directions & technical specifications
For Horizontal Roofs
2. GUARD BUILDING
NOTES:
1- The quantities for these B.O.Q. and the works related to foundation designs and site designs for all engineering specialtie
estimative quantities made on the basis of hypothetica l foundation designs as they have been calculated on the basis of a so
strength of 8 ton/ m2 , and the necessary adjustments must be made to them according to the soil m vest1gat1o ns and exa
be implemented instead of the default principles mentioned in the typical design, as well as the case with regard to the site a
hypothetical design site that will also be modified later after the shape and dimensions of the plot of land allocated to the pr
provided that it does not affect the character of the orig in al design (typical) of the school building and all these actions tak
obtaining the approval of the employer for approval before implementation.
2-We considered that the natural ground level N.G.L=0.3 after skimming process, to calculate the earth works quantities wh
adjustment to soil under dump proofing layer according to what is proven in the design drawings.
3-The quantities of clearing and grabb ing , Leveling and alignment works which is written down in the B.O.Q. of School B
calculated for the whole site.
4-All items for preparing the typica l design for schools, conducting site surveys for the project site , conducting soil investi
project site, have been fixed in the B.O.Q. as shown below, and all of them are done after signing the project implementatio
each site separately.
5-The B.O.Q do not include the furnishing works and the responsibility for these works falls on the shoulders of the benefic
it determined later.
Earth Works
Excavation work in accordance with technical specifications and construction plans, including the work of filling th
foundations with the same soil resulting from excavation, clean and suitable for backfilling, the work also including
compactions to the natural ground level (N.G.L.) and assigning the foundations sides in case they are needed.
-For Strips Foundations
Depth not more than (1.5) m
-For Walkway Floors
Depth not more than (0.5) m
Backfilling with sub-base materials type (B) , the work shall be including spraying and good compaction (95%) as
consultant engineer's directions & technical specifications
-For Strips Foundations
Thickness 250 mm
Backfilling with sub-base materials type (B) , the work shall be including spraying and good compaction (90%) as
consultant engineer's directions & technical specifications
-For Floors
Thickness 150 mm
-For Walkway Floors
Thickness 150 mm
Misalliance Items
Termite treatment for foundation's excavation , foundation's backfilling and floor's backfilling , provided that the type of
used, its specifications established by the manufacturer and the method of its use shall be submitted for approval by the en
using it according to the drawings & technical specifications
Dewatering of ground water collected by pumps and as per consultant engineer's directions and technical specifications
Items)
Concrete Works
Reinforced concrete using one layer of B.R.C No 63, compressive strength (25 N/mm2, cube test, 28 days) using sulfhte res
cement, the work shall be including formwork, steel reinforcement work and expansion Joints work as per drawings, consul
engineer's directions & technical specifications
-For Floors
Thickness l00 mm
-For Floors Under Masonry Brick Partitions
Thickness 250 mm
-For Walkway Floors(Including Making The Required Slope)
Thickness 100 mm (Fair Face)
Preparing materials and make the curbstones paving mold dimension (150x300x1000) mmtype (D/20) the work shall be inc
excavation and preparation and making a layer of non-reinforced concrete for base and back type (DY/20) and cement mort
drawings, chapter (B8,R11A,R11 table B8/5) of the specifications of roads and bridges and their modifications
Laying One layer of agricultural nylon sheet as per drawings and technical specifications
-For Floors
-For Walkway Floors
Refilling the joints between the external walls and walk way floors with mastic materials as per drawings, consultant engine
directions & teclinical specifications
Concrete Works
Non-reinforced concrete (screed concrete) compressive strength (15 N/mm 2, cube test. 28 days) using sulfete resisting cem
shail be including formwork as per drawings, consultant engineer's directions & technical specifications
-For Strips Foundations
Thickness 50 mm
Non-reinforced concrete (blinding concrete) compressive strength (15 N/mm,cube test, 28 days) using sulfate resisting ce
work shall be including formwork as per drawings, consultant engineer's directions & technical specifications
-For Strips Foundations
Thickness 100 mm
Reinforced concrete , compressive strength (30 N/mm2 cube test, 28 days) using sulfate resisting cement, the work shall be
fbnnwork, steel reinforcement work as per drawings, consultant engineer's directions & technical specifications.
-For Strips Foundations
Thickness 300 mm
-For Columns Adjacent To Soil
Masonry Works
Built with brick type (A) and cement mortar with mixing ratio (1:3) using sulfate resisting cement as per drawings, consult
directions & technical specifications
-For Walls Adjacent To Soil
Width 240 mm
Rendering with cement mortar with mixing ratio (1:3) using sulfate resisting cement as per drawings, consultant engineer's
technical specifications.
-For Walls Adjacent To Soil from both side
Laying and painting with three layers of protective layer as per drawings, consultant engineer's directions & technical spec
-Under Foundations
-For Foundations Tops & Sides (Strips and separate) , Walls And Columns Adjacent To Soil
Concrete Works
Non-reinforced concrete, compressive strength (25 N/mm2, cube test, 28 days) using sulfate resisting cement, the work sha
including formwork and mixing water proofing materials (sika chemical material) as per manufacturer company instruction
consultant engineer's directions & technical specification.
For Dump Proof Layer D.P.C.
Dimension 240x150 mm
Reinforced concrete, compressive strength (25 N/mm 2, cube test, 28 days) work shall be including formwork and steel reinf
work as per drawings, consultant engineer's directions & technical specifications.
For Lintels
For Beams
Masonry Works
Built with brick type (B) and cement mortar with mixing ratio (1:3) as per drawings, consultant engineers directions & tech
specifications.
-For Walls
Thickness 240 mm
Metal Works
Cat ladder of steel square hollow tubes section dimensions (50x50) mm and thickness (1.8) mm with steps of steel square h
section dimensions (25x25) mm and thickness (1.5) mm fixing each (300) mm, at the height of Cat ladder the work shall be
fixing accessories with the waEs of steel tubes, steel plates 、 bolts and welding 、 painting with one layer of red led mater
Javers of oil paint as per drawings, consultant engineer's directions & technical specifications.
-For Cat Ladder Width 700 mm and vertical height 4400 mm
Concrete Works
Reinforced concrete , compressive strength (30 N/mm2, cube test, 28 days) , works shall be including all formwork and ste
reinforcement work as per drawings, consultant engineer's directions & technical specifications .
For Ceiling
Thickness 180mm
For Beams
For Parapets
Thickness 150 mm
Concrete Works
Reinforced concrete , compressive strength (30 N/mm2, cube test, 28 days) , works shall be including all formwork and ste
reinforcement work with all fixing works between concretes columnsand brick walls by using steel plate of dimensions (PL
mmfixed each (600) mm upon wall height as per drawings, consultant engineer's directions & technical
specifications .
For Columns
Metal Works
Aluminum windows with frame thickness (2) mm for both of them the practicable section must be good manufacture with t
insulation , the pilling up of sections must be done by pressing wav without bolts (colors and sections for frame specify by a
consultant engineer later). The work shall be includes installing an steel sub frame during construction process also includes
accessories hinges, handles, single transparent , thickness (6) mm and the work also include fly mesh for movable leafs & th
filling material between the frame and wall as per drawings, consultant engineer's directions & technical specifications.
-For Windows
Type W1 Dimension 1800 x 1500mm
Type W4Dimension 600 x 600mm
Steel doors complete with frame and pressed by steel plate gauge 16 from both sides, installing an steel sub frame during co
process, painting with one layer of red led material and three layer of oil paint with all fixing accessories, locks from fore
known manufacture, door stopper ,hinges, handles as per drawings, consultant engineer's directions & technical specificatio
-For Single Doors
Type D14 Dimension 1000x2400 mm
Plastic doors (P.V.C.) complete with frame with (the practicable section must be good manufacture with thermal insulation
be specify bv architectural consultant engineer later).The work includes installing an steel sub frame during constructionpro
fixing accessories、hinges, handles, locks from foreign well-known manufacture. door stopper the work a
拉 ying a space below the door a height of (50) mm & also includes fixable filling material between the f
wall as per drawings 、consultant engineer's directions & technical specifications.
- Single Doors
Type D4 Dimension 800 x 2100 mm
Smooth cement plastering with mixing ratio (1:3), the work shall be including leveling by using vertical rulers as per drawin
consultant engineer's directions & technical specifications
-For Walls
-For Parapets From Inside
Smooth cement plastering with mixing ratio (1:3), as per drawings, consultant engineer's directions & technical specificatio
-For External Ceiling
Painting with Matt Aclyric paint with a good quality, resistance the weather condition, washable, three layers, the first layer
layer and two layer of finishing paint upon it in accordance of the manufacturerand as per drawings, consultant engineer's d
technical specifications
-For Walls
-For External Ceiling
Installing marble skirting of thickness (20) mm by cement mortar with mixing ratio (1:3) the work includes filling joints wi
cement as per drawines, consultant engineer's directions & technical specifications.
For Skirting(light color)
Height 150 mm
Juss plasterine, the work shall be including layer of gypsum mokhammer , leveling by using vertical rulers and all of steel
drawings, consultant engineer's directions & technical specifications
-For Walls
Painting with Matt Aclyric paint with a good quality, resistance the weather condition, washable, three layers, the first layer
layer and two layer of finishing paint upon it in accordance of the manufacturerand as per drawings, consultant engineer's d
technical specifications
-For Walls
Covering by ceramic tiles of dimensions (300x600) mm and cement mortar of mixing ratio(1:3), the work include filling jo
white cement, also include all metal angle for comer and around windows and door opining as per drawings, consultant eng
directions & technical specifications
-For Walls
Installing by non- slip ceramic tiles of dimensions (300x300) mm and cement mortar with mixing ratio (1:3), the work shal
laying one layer of water proofing bitumen for floor under the ceramic and walls with height (300) mm on walls and filling
white cement as per drawings, consultant engineer's directions & technical specifications -For Floors
-For Floors
Installing ceramic skirting resistant to chemicals of dimensions (300x300) mm and cement mortar with mixing ratio (1:3) a
drawings, consultant engineer's directions & technical specifications
For Skirting
Height 100 mm
Cement plastering with mixing ratio (1:3) due to drawings, consultant engineer's directions & technical specifications
-For Ceilings
Juss plastering,the work shall be including layer of gypsum mokhammer a as per drawings, consultant engineer's direction
specifications
-For Ceilings
Painting with Matt Aclyric paint with a good quality, resistance the weather condition, washable, three layers, the first layer
layer and two layer of finishing paint upon it in accordance of the manufacturerand as per drawings, consultant engineer's d
technical specifications
-For Ceilings
Painting with oil paint with three layer of finishing paint as per drawings, consultant engineer's directions & technical speci
-For Ceilings
Laying layer of prime coat, non- reinforcement concrete slopins layer, compressive strength (15N/mm 2, cube test, 28 days),
between (80-130) mmto obtain the required slope ( slope 1 %)towered the gutter, the work shall be include expansion joint
filling the joints by mastic or any filler, flexible and moisture wicking material with cauterization, laying a layer of water pr
thickness (20) mm , layer of thermal insulation thickness (50) mm , layer of clean sand thickness (20) mm, pre- cast concre
dimension (800x800x40) mm , the work include also extending the work of anti-humiditv material to the height of (50) mm
height point of roofing for beams & parapets, with joints filled with mastic and cauterization, non-reinforced skirtins with c
strength (25N/mm2, cube test, 28 days) dimension (150x150) mm and all the work needed to complete as per drawings, con
engineer's directions & technical specifications.

-For Horizontal Roofs


TOTAL AMOUNT CARRIED TO FINAL SUMMARY OF ARCHITECTURAL & STRUCTURAL WORKS FOR S
3- Yards & Car Parking Works
GENERAL NOTES
1- All the items in B.O.Q. consist of supplying and transporting materials, working and fixing, inspection and operation a
the recommendations of the engineer or whoever authorizes him in writing and the technical specifications .
2- All materials used are from sober, reliable , Western European sources of very good quality and conform to privat
technical specifications and are subject to the approval of the engineer or whoever the engineer authorizes in wi
processing or implementation, and all forms are formally delivered to him and the approval is obtained from him officially.
3- The contractor must employ provisional engineers to supervise the work.
4- The contractor must take measures to ensure the safety of the neighboring areas of work (in facilities , services, etc.) an
disrupt any services network.
5- The contractor must remove the rubble outside the site boundaries and in the areas permitted by the Baghdad Municipa
that the school is in the Baghdad Governorate and the provincial municipalities in the case that the school is in the governor
6- The contractor must provide catalogs for the equipments that will be used in the work according to specifications in B
engineering specializations.
7- The contractor must submit the (Shop Drawing) for all the necessary works items, according to the direction of the eng
whoever authorizes him in writing to obtain approval from him before implementation .
8- The brick which is using for sub structure masonry works under damp proof layer (The works adjacent to soil) should b
the brick which is using for super structure masonry works upper damp proof layer should be type (B) for walls and partitio
9- The sub - base which is using in backfilling works under foundations, floors, walkway floors, stairs on earth, roads an
should be type (B) unless otherwise stated in the text of the paragraph.
10- All the steel work should be painted by one layer of anti-corrosion paint conformable to specifications before fixing an
layer after fixing.
11- The co11tactor must supply (As Built Drawing) after completion of the work and it must signed and approved officiall
resident engineer.
12- The specification of B.O.Q and specifications mentioned on the drawings are reliable and the general technical specific
by Ministry Construction, housing and public municipalities are considered to be complementary in the absence of mention
material or paragraph in special specifications.
13- All the quantities listed in B.O.Q. are estimative quantities according to design drawings and site survey and based 0
stander guidebook for quantity surveying works.
14- The work shall be carried out in accordance with the detailed plans and estimation B.O.Q.
15- In the elements which are adjacent to the soil, the contractor should use sulfate resisting cement.
Notes:-
1- The quantities for these B.O.Q. and the works related to foundation designs and site designs for all engineering spec
estimative quantitie s made on the basis of hypothetical foundation designs as they have been calculated on the basis of
bearing strength of 8 ton/m2 , and the necessary adjustments must be made to them according to the soil investi
examinations to be implemented instead of the default principles mentioned in the typical design, as well as the case with
site as it is a hypothetical design site that will also be modified later after the shape and dimension s of the plot of land a
the project, provided that it does not affect the character of the original design (typical) of the school building and all th
takt; place after obtaining the approval of the employer for approval before implementation.
2- We considered that the natural ground level N.G.L=(-0.3) after skimming process, to calculate the earth works quantiti
adjustment to soil under dump proofing layer according to what is proven in the design drawings.
3- The quantities of clearing and grabbing, Leveling and alignment works for Yars, Car Parking &Walkway were calculat
section of (Clearing and grabbing, Leveling the surface area and alignment works) which is fixed in theB.O.Q. of School Bu
4- All items for preparing the typical design for schools, conducting site surveys for the project site , conducting soil inve
the project site, have been fixed in the B.O.Q. School Building­Preliminary & Preparation Works (- -).

Earth Works
Excavation work as per technical specifications & structural drawings.
For Yards &Car Parking
Depth not more than (0.5) m
Backfilling with sub-base materials type (B), the work shall be including spraying and good compaction (90%) as per draw
consultant engineer's directions & technical specifications.
For Yards &Car Parking
Thickness 150 mm
Laying One layer of agricultural nylon sheet as per drawings and technical specifications
For Yards &Car Parking
Concrete Works
Reinforced concrete using two layer of B.R.C No.(63) compressive strength (25 N/mm2 cube test, 28 days) using sulfate re
cement, the work shall be including formwork steel reinforcement Work and expansion joints work as per drawings ,consu
engineer's directions & technical specifications.
For Yards &Car Parking (fair Face)
Thickness 200 mm
Preparing material and make the curbstone paving mold with dimension (150x300x1000) mm type (D/20) the work shall be
excavation and preparation and making a layer of non-reinforced concrete for base and back type (DY/20) and cement mort
drawings, chapter (B8, R11A, R 11 table B8/5) of the specifications of roads and bridges and
their modifications
Miscellaneous Items
Termite treatment for foundation's excavation of yards floors & walkway foundations, backfilling of yards floors &
foundations, provided that the type of material to be used, its specifications established by the manufacturer and the method
shall be submitted for approval by the engineer before
using it according to the drawings & technical specifications
Dewatering of ground water collected by pumps and as per consultant engineer's directions and
technical specifications (Provisional Items)
Yards& Car Parking WORKS
TOTAL AMOUNT CARRIED TO FINAL SUMMARY OF ARCHITECTURAL & STRUCTURAL WORKS FOR S
4- Garden and Green Areas Works
Notes:-
1- The quantities for these B.O.Q. and the works related to foundation designs and site designs for all engineering special
estimative quantities made on the basis of hypothetical foundation designs as they have been calculated on the basis of a soi
strength of 8 ton/m2, and the necessary adjustments must be made to them according to the soil investigations and examina
implemented instead of the default principles mentioned in the typical design, as well as the case with regard to the site as i
hypothetical design site that will also be modified later after the shape and dimension s of the plot of land allocated to the p
provided that it does not affect the character of the original design (typical) of the school building and all these actions take
obtaining the approval of the employer for approval before implementation .
2- We considered that the natural ground level N.G.L=(-0.3) after skimming process, to calculate the earth works quantiti
adjustment to soil under dump proofing layer according to what is proven in the design drawings.
3- The quantities of clearing and grabbing, Leveling and alignment works for Garden, Green Areas & Concrete Sets were
within the section of
(clearing and grabbing, Leveling the surface area and alignment works) which is fixed in the B.O.Q. of School Building .
4- AII items for preparing the typical design for schools, conducting site surveys for the project site , conducting soil inve
the project site, have been fixed in the BOQ. School Building­Preliminary & Preparation Works (- -).
Earth Works
Excavation work in accordance with technical specifications & structural drawings
For Garden and Green Areas
Depth not more than (0.5) m
Backfilling with clean clay empty from impurities and suitable for agriculture with thickness not less than 300 mm the work
leveling according to the required level and making watering channel as per drawings, consultant engineer's directions & te
specification
For Garden and Green Areas
Miscellaneous Items
Termite treatment during excavation , provided that the type of material to be used, its specifications established by the man
and the method of its use shall be submitted for approval by the engineer before using it according to the drawings & techni
specifications
Dewatering of ground water collected by pumps and as per consultant engineer's directions and
technical specifications (Provisional Items)

5- External Fence and Main Gates Works


TYPE 4 - INTERMEDIATE OR SECONDARY SCHOOL (18) CLASSES/Type NO.4/Site works/External Fence and
Gates Works
Earth Works
Excavation work in accordance with technical specifications and construction plans, including the work of filling the side o
foundations with the same soil resulting from excavation, clean and suitable for backfilling, the work also including sprayin
compactions to the natural ground level (N.G.L.) and assigning the foundations sides in case they are needed.
For Separate &Strips Foundations
Depth not more than (1.5) m
Backfilling with sub-base materials type (B), the work shall be including spraying and good compaction (95%) as per drawi
consultant engineer's directions & technical specifications
Under Separate &Strips Foundations
Thickness 250 mm
Concrete Works
Non-reinforced concrete (Screed concrete) compressive strength (15 N/mm 2 , cube test, 28 days) using sulfate resisting ce
work shall be including formwork as per drawings, consultant engineer's directions & technical specifications
Under Separate &Strips Foundations
Thickness 50 mm
Non-reinforced concrete (Blinding concrete) compressive strength (15 N/mm 2 , cube test, 28 days) using sulfate resisting
work shall be including formwork as per drawings, consultant engineer's directions & technical specifications
Under Separate &Strips Foundations
Thickness 100 mm
Reinforced concrete compressive strength (25 N/mm2 cube test 28 days) using sulfate resisting cement, the work shall be
formwork and mixing water proofing materials (sika chemical material) as per manufacturer company instruction. drawin
consultant engineer's directions & technical specification
For Dump Proof Layer D.P.C.
Dimension 240x150 mm
Reinforced concrete compressive strength (30 N/mm2 cube test 28 days) using sulfate resisting cement, the work shall be
formwork and mixing water proofing materials (sika chemical material) as per manufacturer company instruction. drawin
consultant engineer's directions & technical specification
For Separate &Strips Foundations
Thickness 300 mm
For columns Adjacent to soil
Reinforced concrete compressive strength (25 N/mm2 cube test 28 days) the work shall be including formwork and mixing
proofing materials (sika chemical material) as per manufacturer company instruction. drawings, consultant engineer's di
technical specification
For Tie Beams Upon Brick Wall
Dimension 250x200 mm
Reinforced concrete, compressive strength (30 N/mm 2 cube test, 28 days), works shall be including all formwork and s
reinforcement work with all fixing works between concretes columns and brick walls by using steel plate of dimensions (PL
mm fixed each (600) mm upon wall height as per drawings, consultant engineer's directions & technical specifications
For Columns
Masonry Works
Built with brick type (A) and cement mortar with mixing ratio (l :3) using sulfate resisting cement as per drawings, consult
directions & technical specifications.
For Walls Adjacent To Soil
Width 240mm
Built with brick type (B) and cement mortar with mixing ratio (1:3) as per drawings, consultant engineer's directions & tech
specifications
For Walls
Thickness 240 mm
Rendering with cement mortar with mixing ratio (1:3) using sulfate resisting cement as per drawings, consultant engineer's
technical specifications
For Walls Adjacent To Soil from both side
Laying and painting with three layers of protective layer as per drawings, consultant engineer's directions & technical speci
Under Foundations
For Top & Side of Foundations & Walls 600
Adjacent To Soil
Masonry Works
Installing expansion joints with all the work needed of filling material & covering from two faces as per drawings
engineers directions technical specifications
Termite treatment for foundation's excavation , fou:1dation's backfilling, provided that the type of material to be used, its sp
established by the manufacturer and the method of i-cs use shall be submitted for approval by the engineer before using it a
the
drawings & technical specifications
Dewatering of ground water collected by pumps and as per consultant engineer's directions and
technical specifications (Provisional Items)
Finishes Works
Smooth cement plastering with mixing ratio (1:3), the work shall be including leveling by using vertical rulers as per drawin
consultant engineer's directions & technical specifications
For Walls
Paining with matt acrylic paint with a good quality, resistance the weather condition, washable, three layers. the first layer
layer and two layer of finishing paint upon it in accordance of the manufacturer and as per drawings, consultant engineer's d
technical specifications
For Walls
Installing marble skirting of thickness (20) mm by cement mortar with mixing ratio (1:3) the work includes filling join
white cement as per drawings, consultant engineer's directions & technical specifications
For Skirting (Light Color)
Height 150 mm
Metal Works
Fence of hollow square steel tubes of section dimensions (50x50) mm with irregular ornamented & perforated steel plate m
CNC method in the medal thickness (2) mm the work shall be including all fixing accessories with fence walls and columns
painting with one layer of red led material,three layers of oil paint and all the work needed to complete as per drawings, c
engineer's directions & technical specifications
For Steel Fences
Height 700 mm
Steel slide doors of hollow square steel tubes of section dimensions (100x50) mm and covering by two layers of steel plates
(2) mm for each one of them, one of them smooth and the other is irregular ornamented steel plate making by CNC method
shall be including fixing accessories with concrete column and painting with one ]aver of red led Material, three laye
and also include the steel rails and steel wheels and locks from foreign well-known manufacture. handles and all the work n
complete as per drawings. consultant engineer's directions & technical specifications
Slide Doors
Dimension 3200 x 1900 mm
Metal Works
Steel single doors of hollow square steel tubes of section dimensions (50x50) mm and covering by two layers of steel plates
(2) mm for each one of them, one of them smooth and the other is irregular ornamented steel plate making by CNC method
shall be including fixing accessories with concrete column and painting with one layer of red led Material, three layer
and also include the steel rails and steel wheels and locks from foreign well-known manufacture. handles and all the work n
complete as per drawings. consultant engineer's directions & technical specifications
Single Fences
Dimension 1450 x 1900 mm
External Fence and Main Gates Works
Total Amount Carried to The Final Summary of Structural, Architectural works for site.

FINAL SUMMARY of P2
Typical School Buildings Project(Districts & Sub-Districts) Intermediate Or Secondary School (18) Classes /Type No(4)
1- Bathroom Building & Sanitary Services Room Works
2- Guard Building works
3- Yards & car parking Works
4- Garden and Green Areas Works
5- External Fence and Main Gates Works

Total Amount Carried to The Final Summary of Structural, Architectural and Services Works for Site

SANITARY WORKS
Site works
Water Supply Network
Water Supply NetworkWater Supply And Fire Pipe

Excavation Backfilling & pipe work for feeding lines:


Excavation trenches in any kind of soil what ever nature & removal of pockets of soft material or loose rock from the bottom
excavation, placement & compaction of required backfill (after laying Jointing & testing of pipe lines )&disposal of surplus
directed by the Engineer, supply of HDPE-PE100-PN16 Pipes (16Kg/cm2) working pressure, laying, jointing & testing the
trenches with a test pressure not less than (10Kg/cm2) for not less than 8 hrs. The minimum height of pipe cover shall be (9
main pipes from natural ground level & (60cm) for branches. The laying of pipes shall be done after placing sand & gravel
max. size filling in pockets from where soft material ...etc. has been removed & after placing (15cm) thickness sand & grav
pipes & (30cm) thickness above the pipes & all around. The work includes the construction of thrust blocks at every bends
connection & a protection for the pipe crossing under roads or other pipes. The work includes the testing & disinfections of
& site clearance. The work shall be done according to drawings, PN 16 Kg/cm2 according to B.S specifications and as direc
Engineer.
HDPE (20mm dia)
HDPE (25mm dia)
HDPE (32mm dia)
HDPE (63mm dia)
IRRIGATION WAOKS:
IRRIGATION PIPE
Excavation Backfilling & pipe work for feeding lines: Excavation trenches in any kind of soil what ever nature & removal o
soft material or loose rock from the bottom of excavation, placement & compaction of required backfill (after laying Jointin
of pipe lines )&disposal of surplus materials as directed by the Engineer, supply of HDPE-PE100-PN16 Pipes (16Kg/cm2)
pressure, laying,jointing & testing the pipes in trenches with a test pressure not less than (10Kg/cm2) for not less than 6 hrs
minimum height of pipe cover shall be (90cm) for main pipes from natural ground level & (60cm) for branches. The laying
shall be done after placing sand & gravel of (20mm) max. size filling in pockets from where soft material ...etc. has been re
after placing (15cm) thickness sand & gravel below pipes & (30cm) thickness above the pipes & all around. The work inclu
construction of thrust blocks at every bends & tee connection & a protection for the pipe crossing under roads or other pipe
includes the testing & disinfections of the network & site clearance. The work shall be done according to drawings, PN 16 K
according to B.S specifications and as directed by the Engineer.
HDPE (45mm dia)
HDPE (25mm dia)
HDPE (20mm dia)
Control valve chamber for irrigation
Excavation and backfilling and supply materials for constructing an inspection chamber of concrete using sulphate resisting
the cover for inspection chamber shall be pre-cast concrete with opening from heavy duty cast iron cover and frame. The fin
shall be the same as walkways. The item includes supply and fix step iron and concrete below valve. The work shall be don
drawings and as directed by the Engineer.
-contral valve chambers clear dimensions (60x60) cm.

Excavation and backfilling and supply materials for constructing an inspection chamber of concrete using sulphate resistin
the cover for inspection chamber shall be pre-cast concrete with opening from heavy duty cast iron cover and frame. The fi
shall be the same as walkways. The item includes supply and fix step iron and concrete below valve. The work shall
drawings and as directed by the Engineer.
-contral valve chambers with 100mm water meter and 25 mm gate valve valve clear dimensions (60x60) cm.
SEWAGE NETWORKS
U.P.V.C DRAINAGE PIPE
Supply, install and test U.P.V.C drainage pipe high-pressure type(8bar) of following diameters according to B.S.(4660)for u
the manufactures instruction &detail drawing .This will include all fittings, supports, hangers, concrete surrounding for shal
etc... using rubber gasket joints and include excavation, backfilling with sub base or any granular materials.
-.P.V.C. (160) mm dia.
Supply the matererial and construction of Manhole are manufactured at amixer ratio(1:5,1:3)salt resistant cement is used fo
works according to the technical specifications ,the depthe of manhole measured from bottom of outer pipe to under cover o
manhole,the price involve all materials and required works as a paint with epoxy(acid resistance)with three perpendicular la
from outside with flancott with three layers orthogonal after curing the concrete, identifying the pipe opening for pipes conn
inspection through prior to casting to avoid sump collapse or cracking during fracturing and to implement to RWS at structu
location with aneck less than 2.5 m below the surface natural ground level.the outlet shall be the two normal types(ramp ma
event that the difference in levels is up to (60-100)cm,and the downward type with a vertical downward pipe of the same di
inlet pipe with all accissoris bends,in the evevt that the difference in the levels is greater than (100)cm(drop manhole)and th
of water of all kinds and supports for excavation,molding burial with earth and hammering,then burial with hidden gravel th
30 cm from the level of the bottom of the the paving with good compaction of these forms

Manhole (50 x 50) cm.


Manhole (70 x 70) cm.
Manhole (60 x 90) cm.
RAIN WATER NETWORK
Ditto as item (4-1) above, but for rainwater network.
U.P.V.C pipe (160) mm. dia.
U.P.V.C pipe (200) mm. dia.
Ditto as item (2-3) above, but for rainwater network.
Manhole (60 x 60) cm.
Manhole (60 x 90) cm.
Supply, install and test water tap with base concrete to water supply feeding and shall be good quality made with all necessa
accessories.
Supply , all material and constructing street inlet in sulphate resisting cement and rendered with sulphate cement mortar 1:2
supplying and fixing heavy duty cast iron grating cover as per standard detail.
-Street inlet (35x50)cm.
PUPIL BATHROOMS BUILDING
SEWAGE NETWORKS
U.P.V.C DRAINAGE PIPE
Supply, install and test U.P.V.C drainage pipe high-pressure type(8bar) of following diameters according to B.S.(4660)fdr u
the manufactures instruction &detail drawing .This will include all fittings, supports, hangers, concrete surrounding for shal
etc... using rubber gasket joints and include excavation, backfilling with sub base or any granular materials.
-.P.V.C. (110) mm dia.
-.P.V.C. (50) mm dia.
Gully traps
Supply, install and test U.P.V.C gully traps with all connections as shown on the drawings, the trap should be surrounded by
thickness with water proofing materials for ground floor and gully traps in upper floors with all connections and hangers etc
on the drawings and specified by the Engineer.
-110 mm dia. with brass chromium plated grating cover with hinged solid cover soleplate resisting cement of 15 cm
RAIN WATER WORKS :
RAIN WATER PIPES:
Supply, install & test U.P.V.C (8bar) rainwater pipes(vertical &horizontal inside buil.) high pressure type of following diam
according to the specification B.S.4514 instruction in side buildings. This will included all fiings support hangers,outlets, et
solvent type joints with good quality tangent &approved by an engineer.
-U.P.V.C pipe (110) mm. dia.
-Supply,install and test cast iron domical rainwater outlet, made of cast iron body with combined flashing clamp and gravel
polyethylene dome,of following nominal internal diameter conforming to B.S The work shall include fixing, water proofing
cover with chain, also the work shall include connection with vertical rainwater pipes.
Rainwater outlet(110)mm.dia
Cold & Hot water suddIy:- Supply, install and test aluminum reinforced polypropylene water pipes (PN16) according to D
DIN 16962 or any approved specification for cold, and hot water pipes inside the building of following, and valve.the pipes
under pressure of no less than (10)bar or 150% of the operating whichever is greater for a period of (24)hours and is consid
acceptable after passing examination approved by consulting engineer ,This includes all fittings, valves, wherever needed o
branches, supports, and according to the internal diameters,etc.
-15 mm dia.
-20 mm dia.
-25 mm dia.
-32 mm dia.
-40 mm dia.
GALVANIZED STEEL PIPES:
Supply, install and test galvanized steel welded pipes to B.S. 1387 heavy weight, installed, jointed, and tested complete with
steel fittings, accessories, supports, hangers using clamps with rubber inlay, threaded rods, sleeves, pipe marking, expansion
pipes are test under pressure of no less than (10)bar or 150% of the operating whichever is greater for a period of (24)hours
considered acceptable after passing examination approved by consulting engineer , This includes all fittings, valves, wherev
main lines branches, supports all as specified and shown on drawings
-50 mm dia.
-40 mm dia.
-32 mm dia.
Polvethvlene water tanks:
Supply, install and test water tanks of heat-resistant plastic and bacteria growth (polyethylene)from an approval origin, the p
all that is related of accessories tank such as pipes attaching connection to tank,maintenance float of 20mm dia,over flow pi
pipe20mm,gate valve,the price includes the preparation and erection of concrete bases from precast,before the completion o
flattening works,to be height of 15 cm,according to the approval of sanitary and civil plans
water tank size 1 m3
European Water Closet with handicapped:
Supply , install test White European water closet as shown in the drawings and as specified to approval to Engineer, consist
storage glazed vitreous china has(61iter) at least fron low type with seat and cover, fixing by bolt and connection to water b
chrome plating and nuts from chrome made with all necessary accessories.
Eastern Water Closet:
Supply, install & test eastern water closet as shown on the drawings & as specified to the approval of eng. With ahigh tank
plastic, a water pipe coming down from the tank of plastic, diameter of 32 mm,with a manual water hose with all necessary
European Water Closet :
Supply , install test White European water closet as shown in the drawings and as specified to approval to Engineer, consist
storage glazed vitreous china has(61iter) at least fron low type with seat and cover, fixing by bolt and connection to water b
chrome plating and nuts from chrome made with all necessary accessories.
Lavatory:
Supply, install and test white glazed vitreous china lavatory basin as shown in the drawings and as specified to the approval
with self contained overflow 15 mm cold and hot water supply mixer , drainage plug and chain waste. All exposed brass wo
chrome plated The work shall include soap holder one towel holder, shelf, mirror, and all accessories.
-Size (56 x 40) cm install on marble
-Size (56 x 40) cm with stand

Electric water heater:


Supply, install and test electric water heater, vertical type, enamel coated tank, 25 mm Aluminum injected polyurethane ins
complete with all accessories and connection such nun return valve, isolating valves, automatic air vent, electric heater acce
without draining the water heater, titanium or magnesium anode, thermostat with safety cut-out, safety group, tundish in CP
indirect water discharge to drain, and accessories, all as specified and shown on drawings, with all electrical connections, w
220v, 50 Hz, A.C current.
-E.W.H of 100 lit, 3 kW

Supply,install and test a water cooler with a capacity of not less than 30 liters of the type equipped withpressure faucets and
desalination and sterilization system with a capacity suitable for ultraviolet rays,water cooler is made of stainless steel (316
steel),shall be works with an alternating current,AC voltage 240 V and frequency 50 HZ with connection water and sewage
electric connection, the price includes all works requirement and accessories and approval of engineer.
TANKS ROOM
PRESSED STEEL TANK
Supply, install and test pressed steel main water tanks (water supply and fire fighting) in site, constructed of standard (1.22m
mm thick hot dipped pressed steel plate galvanized according to B.S.1564, cover plates of 3mm thick, tank of two compartm
externally flanged construction, complete with weather proof cover fitted with 600mm diameter one hinged cover and 50 m
one ventilator. All necessary piping connections shall be flanged type, provided and welded at the manufacturing firm.Weig
galvanization should be not less than 600gr/m2. Each tank compartment should be supplied with one internal access ladder,
access ladder, φ100mm one over flow pipe,φ75mm one drain pipe with gate valve, and scour pipe with valve, water level m
indicator. The work includes a concrete supports of 45 cm high, and steel I-section of not less than 15 cm high. The work sh
per drawings, specifications and Engineer approval.
-Size of tank( 2.44x3.66x2.44)m

Water Booster System Pumping Set


Supply, install & test booster station for domestic water consist of:
--2 Nos. of centrifugal pump (one working and one stand-by) each of 5 m3/hr capacity and 30 m head complete with all pip
connections, gate valve, non-retum valve, pressure gages, pressure switches, control panel complete with all accessories. Th
protection type is IP-55.The pumps are ON&OFF switched.by the pressure limit switch with spring arm contact
-1 Nos. Pressure tanks each of 250 liter capacity, made of galvanized 6 mm thickness with all accessories such as pressure g
connections, etc. The dimensions shall be coordinated according to the height of plant room
Firefighting Booster System Pumping Set
Supply, install & test booster station for domestic water consist of:
--2 Nos. of centrifugal pump (one working and one stand-by) each of 10 m3/hr capacity and 40 m head complete with all pi
connections, gate valve, non-retum valve, pressure gages, pressure switches, control panel complete with all accessories. Th
protection type is IP-55. The pumps are switched. ON&OFF by the pressure limit switch with spring arm contact
-1 Nos. Pressure tanks each of 250 liter capacity, made of galvanized 6 mm thickness with all accessories such as pressure g
connections, etc. The dimensions shall be coordinated according to the height of plant room
Supply, install ,test Trolley fire extinguisher have a(45)kg,with reinforced flexible pipe and arm to open by pressure
Supply, install ,test and executing reinforced concrete channel to drain rainwater using salt resistant cement at mixing ratio
pain all internal sides by flancott three layers at least 5 micron thickness, the work include supply and fixing frame and cove
duty cast iron from good quality according to approved engineering. The channel shall be with a width (35)cm,and an initia
20)cm.and all other accessories
GUARD ROOM
Ditto as item (I) from Pupil bathroom above :
-U.P.V.C.(110) mm dia.
-.P.V.C. (50) mm dia.
Ditto as item (2) from Pupil bathroom above :
-P.V.C.(110) mm dia.
Ditto as item (3) from Pupil bathroom above :
-U.P.V.C.(110) mm dia.
Ditto as item (4) from Pupil bathroom above :
-P.V.C.(100) mm dia.
Stainless Steel Sink:
Supply, install and test stainless steel sink in overall with outlet and over flow with 15mm. mixer for cold and hot water inle
bottle trap drain. The price includes fixing sink on counter as per approval of the Architect, of the following dimensions or
dimensions
-single bowel, two wing Size (60x90) cm
Cold & Hot water suddIy:- Supply, install and test aluminum reinforced polypropylene water pipes (PN16) according to D
DIN 16962 or any approved specification for cold, and hot water pipes inside the building of following, and valve.the pipes
under pressure of no less than (10)bar or 150% of the operating whichever is greater for a period of (24)hours and is consid
acceptable after passing examination approved by consulting engineer ,This includes all fittings, valves, wherever needed o
branches, supports, and according to the internal diameters,etc.
-15 mm dia.
-20 mm dia.
Polvethvlene water tanks:
Supply, install and test water tanks of heat-resistant plastic and bacteria growth (polyethylene)from an approval origin, the p
all that is related of accessories tank such as pipes attaching connection to tank,maintenance float of 20mm dia,over flow pi
pipe20mm,gate valve,the price includes the preparation and erection of concrete bases from precast,before the completion o
flattening works,to be height of 15 cm,according to the approval of sanitary and civil plans
water tank size 1 m3
Eastern Water Closet:
Supply, install & test eastern water closet as shown on the drawings & as specified to the approval of eng. With ahigh tank
plastic, a water pipe coming down from the tank of plastic, diameter of 32 mm,with a manual water hose with all necessary
Lavatory:
Supply, install and test white glazed vitreous china lavatory basin as shown in the drawings and as specified to the approval
with self contained overflow 15 mm cold and hot water supply mixer , drainage plug and chain waste. All exposed brass wo
chrome plated -Size (56 x 40) cm. The work shall include soap holder one towel holder, shelf, mirror, and all accessories.
SHOWER TRAY
Supply, install & test shower tray in white glazed vitreous chaina size (80x80x18)cm, complete with drains, stopper, fixing
under the showers as on drawings. The pipe between the drain & the gully is calculate ed with piping item.
SHOWER MIXER
Supply, install & test chromium plated shower head including shower fittings, mixer for hot & cold water, comprising of 15
comminuting supply fitting, shower & 100mm dia. shower rose, connecting pipe & white glazed soap dish, overall size (15
depth from face of 6cm & towel holder.
Electric water heater:
Supply, install and test electric water heater, vertical type, enamel coated tank, 25 mm Aluminum injected polyurethane ins
complete with all accessories and connection such nun return valve, isolating valves, automatic air vent, electric heater acce
without draining the water heater, titanium or magnesium anode, thermostat with safety cut-out, safety group, tundish in CP
indirect water discharge to drain, and accessories, all as specified and shown on drawings, with all electrical connections, w
220v, 50 Hz, A.C current.
-E.W.H of 80 lit, 2 kW

FINAL SUMMARY of P3
Typical School Buildings Project(Districts & Sub-Districts) Intermediate Or Secondary School (18) Classes /Type No(4)
1- SITE WORKS
2-PUPIL BATHROOMS
3- TANKS ROOM
4- GUARD ROOM
Total Amount Carried to The Final Summary of Structural, Architectural and Services Works for Site
ELECTRICAL WORKS
Site works
Feeders & accessories
Supply , extend , test & commission insulated armored copper low tension power cables(XLPE/PVC) sizes as below:
-(4x150) mm2
-(4x6)+(1x6) mm2
Supply and install galvanized iron manhole with tight closed cover sizes as below:
-(80x80x80)cm
-(40x40x40)cm
Supply and extend plastic(UPVC) pipe 70cm under ground surface with all work requirements and pipe accessories sizes as
-(20)cm diameter
Earthine System
Supply, implement , test and commission Earthling system with 1.5 meter length 16mm diameter depth of 70cm under grou
copper rode No./3 connected with (1x70)mm2 naked copper wire burred vertically as 3m length equilateral triangle implem
(40x40x40)cm earthing manhole with cover With all accessories For MDB resistance must be not more than 5 ohm
Electrical transformer
Supply install test & commission (250KVA) transformer with transformation ratio of 11KV/400V ,3ph,50HZ,DY11 group
oil filled naturally air cooled designed for outdoor (H-POLE) type with all accessories circuit breaker, H.T. fuse according t
specification the price including (poles) supply
TANKS ROOM
Insulation for lighting ,fans and exhaust fans
Supply install test operate and commission cell or wall electrical insulation point using single 3x2.5 mm2 copper wires as sh
drawings installed through 20 mm diameter plastic pipes the price include 10A operation switches with all requirement to c
as shown in drawings
a-lighting point
b-exhaust fan point(supplying the fan is not included)
Lighting fixtures
Supply install test operate and commission good quality lighting with all accessories according to technical specification as
bellow:
-ceiling LED lighting fixture (1x40)watts dimension of (120x22)cm (F1)
Power insulation points
Supply install test operate and commission electrical point using single copper wires(3x4)mm 2 insulated inside plastic pipes
20 mm the price including supply and connect sockets of good quality with all requirement to complete work as shown in d
-duplex 13A Sockets
-15A switch socket outlet
Final distribution board
Supply, install, test and commission dust & vermin proof steel distribution boards with door & lock to be fixed in the wall o
incoming non automatic circuit breaker (N.A.C.B.)and many outgoing automatic miniature circuit breaker of ratings as per
good quality types as require:
-12 line
GUARD ROOM
Insulation for lighting ,fans and exhaust fans
Supply install test operate and commission cell or wall electrical insulation point using single 3x2.5 mm2 copper wires as sh
drawings installed through 20 mm diameter plastic pipes the price include 10A operation switches with all requirement to c
as shown in drawings
a-lighting point
b-exhaust fan point(supplying the fan is not included)
Lighting fixtures
Supply install test operate and commission good quality lighting with all accessories according to technical specification as
bellow:
-ceiling LED lighting fixture (1x40)watts dimension of (120x22)cm (F1)
-Circular ceiling LED lighting fixture (1x28)watts dimension of (22)cm IP54(F3)
Power insulation points
Supply install test operate and commission electrical point using single copper wires(3x4)mm 2 insulated inside plastic pipes
20 mm the price including supply and connect sockets of good quality with all requirement to complete work as shown in d
-duplex 13A Sockets
-32A switch include lamp for A.C
-25A switch include lamp for water heater IP54
Final distribution board
Supply, install, test and commission dust & vermin proof steel distribution boards with door & lock to be fixed in the wall o
incoming non automatic circuit breaker (N.A.C.B.)and many outgoing automatic miniature circuit breaker of ratings as per
good quality types as require:
-6 line
BATH ROOM BUIL
Insulation for lighting ,fans and exhaust fans
Supply install test operate and commission cell or wall electrical insulation point using single 3x2.5 mm2 copper wires as sh
drawings installed through 20 mm diameter plastic pipes the price include 10A operation switches with all requirement to c
as shown in drawings
a-lighting point
b-exhaust fan point(supplying the fan is not included)
Lighting fixtures
Supply install test operate and commission good quality lighting with all accessories according to technical specification as
bellow:
-ceiling LED lighting fixture (1x40)watts dimension of (120x22)cm (F1)
-Circular ceiling LED lighting fixture (1x28)watts dimension of (22)cm IP54(F3)
Power insulation points
Supply install test operate and commission electrical point using single copper wires(3x4)mm 2 insulated inside plastic pipes
20 mm the price including supply and connect sockets of good quality with all requirement to complete work as shown in d
-25A switch include lamp for water heater IP54
FINAL SUMMARY of P4
Typical School Buildings Project(Districts & Sub-Districts) Intermediate Or Secondary School (18) Classes /Type No(4)
1- SITE WORKS
2- TANKS ROOM
3- GUARD ROOM
4- BATH ROOM BUIL
Total Amount Carried to The Final Summary of Structural, Architectural and Services Works for Site
MECHANICAL WORKS
Site works
The price for the following items shall be complete supply, install and operation with all necessary accessories and ancillary
including controls and instruments as shown on schedules, drawings and specifications.
Exhaust fan, propeller wall mounted, low noise complete with pull cord and automatic shutter.
Size (mm) M3/HR
φ200 600
φ300 1300
Ceiling fans with a diameter of 140 cm, single-phase complete with a speed regulator, good quality. According to the techn
specifications and the mechanical drawings.
UPVC plastic pipes for the drainage of condensate water for split units at a pressure of not less than 6 bar with all necessary
for installation complete with elbows, tees, reducers .... etc. installed pipes under the level of finishing walls and floors or u
of external wall covering, and connected to the nearest floor drain.
size (mm) φ25mm
PVC plastic pipes, (SLEEVE PIPE) for the passage of insulated copper pipes, electric cable that connects between the outdo
indoor units for wall mounted & floor standing split units, with all necessary accessories for installation according to the me
drawings and directions of the supervising engineer.
size (mm) φ80mm
FINAL SUMMARY of P5
Typical School Buildings Project(Districts & Sub-Districts) Intermediate Or Secondary School (18) Classes /Type No(4)
Total Amount Carried to The Final Summary of Structural, Architectural and Services Works for Site
FINAL SUMMARY of The Typical School Buildings Project(Districts & Sub-Districts)
Intermediate Or Secondary School (18) Classes /Type No(4)
1- SCHOOL BUILDING
2- SITE WORKS
3-SANITARY WORKS
4-ELECTRICAL WORKS
5-MECHANICAL WORKS
Total
ENGINEERING CONSULTANCY

ENGINEERING CONSULTANCY

commendations of the engineer or whoever authorizes him in

etermined later.
specifications and are subject to the approval of the engineer or
val is obtained from him officially.

y services network.
e school is in the Baghdad Governorate and the provincial

ering specializations.
authorizes him in writing to obtain approval from him before

rick which is using for super structure masonry works upper

uld be type (B) unless otherwise stated in the text of the

fter fixing.
gineer.
Ministry Construction, housing and public municipalities are

uidebook for quantity surveying works.

Price Amount
Qty. Unit
ID×1000 ID×1000
L.S L.S NA

L.S L.S not priced by contractor

L.S L.S NA

3500 M2

1820 M3

18 M3

2 M3
1 M3

11 M3

32 M3

75 M3

70 M2

552 M3

6 M3

215 M3

51 M3

2 M3

4 M3

L.S L.S

L.S L.S

1435 M2

130 M2
15 M2
340 M2

25 M2

275 M.L

1435 M2
15 M2
25 M2
340 M2

10 M.L

220 M.L

862 M2

8 M2

955 M2

10 M2

178 M3

233 M3

4 M3
20 M3
1 M3

100 M3
40 M3
2 M3

1083 M2

870 M2
2115 M2

20 M.L
480 M.L
135 M.L
3 M.L
6 M3

25 M3
10 M3

155 M2
2640 M2
175 M2
16 M2

450 M.L

30 M.L

515 M3
160 M3
6 M3
15 M3
75 M3

3 M3
2 M3

50 M.L

22 M3

2 No.
123 M3

80 M.L

3 No.
44 No.
3 No.
3 No.
2 No.
2 No.

1 No.
2 No.
1 No.

2 No.
2 No.

2 No.

1 No.
4 No.

28 No.

3 No.

1 No.

1 No.

25 M.L

40 M.L

60 M.L

305 M2

45 M2

120 M2
2485 M2
580 M2

70 M2

2485 M2
70 M2

240 M2

220 M.L

80 M2

L.S L.S

200 M.L

2570 M2

2840 M2

4970 M2
315 M2

125 M2

200 M2

2275 M2

1325 M.L

15 M.L
25 M.L
95 M.L

75 M2

120 M2

40 M.L

45 M2

205 M2

130 M.L

35 M.L

50 M2
25 M2

30 M2

75 M2

20 M2

95 M2

900 M2

1120 M2

1970 M2
305 M2

50 M2

1330 M2

60 M2

3 M2
Total Amount/ID
85 M.L
35 M.L

11 No.

45 M.L
8 M.L
8 No.
1 No.

57 M.L

40 M.L
30 M.L
40 M.L
35 M.L

55 M.L

1 No.

2 No.

2 No.

4 No.

1 No.

13 No.
2 No.

15 M.L

20 M.L
115 M.L

6 No.

6 No.
6 No.

1 No.

1 No.

298 No.
3 No.
47 No.

193 No.
63 No.
23 No.
17 No.
2
No.

15 No.
96 No.
2 No.
50 No.
2 No.

200 M.L
120 M.L
120 M.L
60 M.L

120 M.L

1 Set

1 No.
2 No.
4 No.
1 No.

8 No.

1 No.
1 Set

5 Nos.
3 Nos.
49 Nos.

180 M.L.

40 M.L.
50 M.L.

180 M.L
100 M.L
150 M³

1 M³

14 M³

10 M³

46 M³

3 M³

14 M³

21 M³

1 M³

L.S L.S

L.S L.S
65 m²

35 m²

5 m²

140 m²

30 m²

30 M.L

1 M³

15 M.L
95 m²
5 m²
140 m²

65 M.L

65 m²

10 m²

75 m²

10 m²

30 M³
3 M³
8 M³
15 M³

125 m²
75 m²
155 m²

9 M.L
75 M.L

3 M³
1 M³

25 m²
260 m²

1 No

27 M³
8 M³
1 M³
7 M³

8 M³
2 No
10 No

1 No
1 No
1 No

9 No

30 M.L

65 m²

295 m²
40 m²

40 m²

295 m²
40 m²

60 M.L

90 m²

90 m²
325 m²

30 m²

25 M.L

65 m²

30 m²

30 m²

135 m²

45 M3

2 M3
8 M3

3 M3

3 M3

L.S L.S

L.S L.S

22 M2

4 M2

20 M2

13 M.L

22 M2
20 M2
23 M.L

20 M2

24 M2

6 M3
1 M3

5 M3
42 M2

20 M2
80 M2

22 M.L

1 M3
1 M3

50 M2

1 No.

7 M3
2 M3
3 M3

2 M3

1 No.
2 No.
1 No.

1 No.

80 M2
16 M2

12 M2

80 M2
12 M2

22 M.L

40 M2

40 M2

40 M2

22 M2

13 M.L

14 M2

8 M2
8 M2

14 M2

38 M2
175 m³

75 m³

500 ㎡

500 ㎡

200 M.L

L.S L.S

L.S L.S

The responsibility for its implementation


rests with the beneficiary
not priced by contractor
The responsibility for its implementation
rests with the beneficiary
not priced by contractor

240 ㎡

The responsibility for its


implementation rests with the
530 ㎡ beneficiary
not priced by contractor

L.S L.S

L.S L.S

525 ㎡

100 m³

245 ㎡

300 ㎡

245 M.L
75 m³
7 m³

15 m³

18 m³

52 m³

375 ㎡

385 ㎡

245 ㎡
600 ㎡

70 M.L

L.S L.S

L.S L.S

1000 ㎡

1000 ㎡

575 M.L
45 ㎡

1 NO.

1 ㎡

30 L.M
22 L.M
50 L.M
30 L.M

45 L.M
30 L.M
55 L.M

1 No.

1 No.

135 M.L

9 No.
6 No.
2 No.

55 M.L
45 M.L

3 No.
1 No.
10 No.

2 No.

45 M.L
25 M.L

7 No.

10 M.L

2 No.

50 M.L
25 M.L
20 M.L
12 M.L
17 M.L

5 M.L
8 M.L
6 M.L

1 No.
1 No.

5 No.

4 No.

16 No.
1 No.

1 No.

2 No.

1 No.

1 Set
1 Set

1 No.

5.5 M.L

18 M.L
7 M.L
2 No.

4 M.L

1 No.

1 No.

8 M.L
10 M.L

1 No.

1 No.

1 No.

1 No.

1 No.
1 No.

100 M.L
150 M.L

1 No.
7 No.

100 M.L

1 Set

1 Set

6 No.
2 No.

6 No.

3 No.
2 No.
1 No.

4 No.
2 No.

3 No.
1 No.

3 No.
1 No.
1 No.

1 No.

20 No.
5 No.

1 No.
19 No.

2 No.

3 Nos.
4 Nos.
1 Nos.

6 M.L

2 M.L