Portable Plasma Torch Height Controller Manual - F1621: Service Support Spirit
Portable Plasma Torch Height Controller Manual - F1621: Service Support Spirit
F1621
Portable Plasma Torch Height Controller
Manual - F1621
Operator Manual
ARCBRO| Revision 2 | English
Work condition
Maintenance
Safety notice
This THC will switch in high electromagnetic, It can hurt me if we get to touch with high
electromagnetic . Do not touch shield cable and wire when power supply is turning on.
Packing pieces must be installed in accordance with the provisions and requirements of
step.
GND must follow THC instruction.
Installation note
THC first check on electrical safety : Before THC first power, Making all port of wiring
connected, then unplug motor cable, in other words, do not connect lifting motor cable
temporarily. Then powering on. (Warning: Motor cable must be unplug before powering on,
otherwise, the reason why the lift motor has been rising (declining) is that may be received
collision signal, It can injury lifting motor)
Check whether the collision function is normal: After THC power on, check
whether the collision detection function is normal, by observing the collision indicator light to
determine whether the normal. Of the following circumstances:
Switching in lift motor safely: After the detection of THC collision has debug and used
normally, please remove all conditions which can made collision, at the same time, THC collision
indicator light should be broken off . Then turning off power source of THC and connecting the
lift motor cable.
Check whether direction of lift move is true: After motor cable has been linked,
power-on ,when check whether the button named 【▲】 in THC faceplate is pressed, observe
whether the lift body is rising; when the button named【▼】is pressed, observe whether the lift
body is declining. If the button named【▲】is pressed, the lift body is declining rather than
Check arc start and used for IHS(initial height sensing): check whether start arc
by pushing button of【text arc start】and check whether accomplish the initial positioning by
pushing button of 【text used for IHS】.
Putting in Arc voltage cable true: The wire of plasma arc voltage and cable of
checking collision must be access to the corresponding port true, otherwise, it can lead to
danger.
Demand that torch retaining cap used for IHS wiring: After the cable of plasma anode must
be received a work piece, the action that detects the torch retaining cap collision and the initial
positioning can work.
Using shielded cable wiring: In order to protect equipment work, please use shielded
cable in our equipment. You can connect shielding layer in Shielded cable to THC side and use
single point grounding.
Voltage divide board and voltage divide ratio: The ratio in THC is 100: 1. And effective
measuring voltage in THC is 0~660V DC
Contents
Work condition ........................................................................................................................... 2
Maintenance .............................................................................................................................. 2
Safety notice .............................................................................................................................. 2
Installation note .......................................................................................................................... 2
Contents .................................................................................................................................... 5
Chapter 1 Overview ................................................................................................................... 6
1.1 equipment presentation................................................................................................. 6
1.2 Features of equipment .................................................................................................. 7
1.3 Function of equipment................................................................................................... 8
1.4 Technique parameter ....................................................................................................11
1.5 THC Installation size .....................................................................................................12
Chapter 2 System operation .....................................................................................................13
2.1 Operation panel button of explaining ...........................................................................13
2.2 operation panel of explaining .......................................................................................14
2.3 Menu operation explain ................................................................................................16
2.4 Motor drive current .......................................................................................................25
2.5 Working process...........................................................................................................25
Chapter3 Port connection .........................................................................................................26
3.1 The case view ...............................................................................................................26
3.2 Chassis port .................................................................................................................27
3.2.1 CNC port .............................................................................................................27
3.2.2 Power supply, motor and motor limit port ...........................................................29
3.2.3 Arc start port and proximity switch position port .................................................31
3.2.4 USB port .............................................................................................................35
3.3 voltage divide port ........................................................................................................37
3.3.1 arc voltage port .........................................................................................................37
3.3.2 torch retaining cap detection circuit port ............................................................38
3.4 The total wiring diagram ...............................................................................................40
Chapter 4 Common problems ..................................................................................................41
Chapter 5 THC parameter alarm description ............................................................................45
5.1. Description: .................................................................................................................45
5.2 Corresponding alarm codes and solutions ..................................................................47
Chapter 1 Overview
Portable Plasma Torch Height Controller type F1621 is a product which has such advantage
as operate simply, stabilize property, full function and high performance ratio. It is made on basis
of condition that used in plasma power source scene, and it absorb a lot of advantage of THC
all around the world.
This equipment uses the basic constant current characteristics of the plasma power supply,
detects the change of the plasma cutting torch height by detecting the change of the plasma
arc voltage, and controls the height between the cutting torch and the workpiece in real time.
It is suitable able for the height control of plasma power cutting torch with constant current
characteristics or constant current characteristics within a certain voltage range. It is more
suitable able for torch height control of portable cutting machine.
The device is light and portable, simple to operate, easy to use, and all buttons and knobs
are humanized design, which is comfortable and convenient.
Our equipment uses nixie tube and LED as arc voltage and signal display, clear display,
The parameter is able to alter by button and rotary knob in our equipment, easy to use.
Our equipment uses the installed way which has 60 degree of slope, it suitable able
Our equipment has voltage divide and make all angle shield by metal, smaller volume,
better anti-interference.
It has simple and convenient parameter which can be set, change operation parameter
It can suitable able external working conditions by changing parameter, so we need not
It can change the electrical level of input signal which is useful. The input signal
acquiesce in low electrical level is useful. The high electrical level is useful when we
change it.
The arc start relay and the arc start prosperity relay is omron power relay, so it is reliable
when it work.
The different work process is mutual seal, it can avoid operate fault.
When THC has a delay of boring a hole, it can use function which it can dynamic bore
It can monitor whether arc start has been start in torch process, if it detect that arc is
breaking off, the THC can inform CNC in time and turn off the arc start relay, it can avoid
to cite arc for empty when arc is breaking off.
When auto height control is proceeding, it also can change the arc voltage setting value,
When auto height control is proceeding, collision signal can feedback for numerical
control system, it can avoid that numerical control system is marching after collision.
When auto height control is proceeding, it can use function which arc voltage can be
After torch has accomplished, THC can automatic promote torch height, and height
5. Manual operation
Many functions can be manual operated on operation panel of THC, such as, set auto/manual
mode of THC, manually control torch up and down, IHS test arc start test.......etc.
6. Auto operate
After numerical control system send arc start signal, THC can automatic accomplish down
initially—arc start—arc start feedback success, after CNC receive signal which arc start
feedback is successful, machine tool start to motion and incise.
8. Menu Operation
When torch is not working, parameters can be changed by panel button. Users can flexibly
change speed, working way and so on.
Output current: 0A-3A (the electric current that motor can input is 5A).
Setting range of arc voltage: 30V~600V, it can change by panel spin button.
THC installation size: width 271mm,depth 190mm(it cannot contain line and port in
back),height 70mm.
THC installation screw of IHS:
1.Displaying with Nixie tube: Arc voltage value is displayed by two nixie tubes in the
front operation panel. During torch do not work and menu operation do not been used, it can
display arc voltage 、IHS 、pierce delay value and so on. The green nixie tube is used to display
arc voltage setting value; the red nixie tube is used for display actual value of arc voltage. Arc
voltage setting value can be changed by turning the button named【ARC SET】
【(ARC SET】),
and the value displayed with green nixie tube will be changed at the same time. The red nixie
tube display 0 when plasma do not been working. The value displayed with red nixie tube is
actual arc voltage value during plasma is working.
AUTO THC indicator: This LED light will be turned on when the THC is working in auto height
controlling processing. If it satisfy four conditions below, the indicator will turn on:
A. The indicator named“AUTO”is turned on.
B. CNC Auto height control enables.
C. THC has sampled valid arc voltage.
D. The sampling arc voltage do not exceed the value added between arc
setting voltage and arc protecting voltage(in general, the value is 30V
and can been changed).
ARC ON indicator: Turn on when THC send arc start signal out. If IHS completed, this
indicator is lighted when THC send arc start signal. During arc start test, the indicator is lighted.
COLLISION indicator: Turn on when torch touch workpiece or proximity switch effective.
AUTO indicator: The indicator up the button named【AUTO】is indicated whether allowed
auto height control. If the indicator is lighted, THC will allow auto height control. If the indicator
is extinguish, THC will not allow auto height control. The indicator is lighted after starting up. The
indicator condition will change when the button named【AUTO】is pressed.
IHS TEST indicator: The indicator up the button named【IHS TEST】is lighted during IHS
test, it means IHS test is working. The indicator is extinguish during other condition.
THC has concise menu, it can set some parameter and adopt to different work condition.
Menu operation use the button named【MENU】、【OK】、【+】、【-】and so on. It also use two
nixie tube to display parameter, the green nixie tube display parameter number and the red nixie
tube display parameter value.
When user use it on the scene, parameter number and meaning can refer to concise
parameter grid up the chassis.
During torch do not work, when arc start and IHS test do not work, user press the button
named【MENU】can enter into the menu operation model. After it enter into the menu model,
the button named【IHS TEST】、
【ARCON TEST】is trashy. Only the button named【▲】、
【▼】
and the signal named THC_UP、THC_DN that CNC send is useful. If THC enter into the menu
model, it will not test and cut.
When THC enter into the menu model, it mean THC enter into first submenu named “Pxx”
(xx is parameter number),if the button named【MENU】is pressed again, THC will enter
into second submenu named“Hxx”. When the button named【MENU】 is pressed, THC can
switch the next submenu. When it has switched the last submenu, if the button named 【MENU】
P00: Recovering factory parameter. P00 can display 1. If user set it as 0 and save this
parameter, all kinds of parameter in our equipment will recover factory parameter. After user
exit the submenu, they can find that P00 display 1.
P01,P02,P03,P04: Setting manual lifting and auto lifting speed of torch. The minimum
P05: The value of promoting arc voltage. During torch is cutting, if gun of torch go through
the crack of torch, arc voltage can rise immediately. If way of protecting arc voltage is not
used, gun of touch will descend by fast speed. In serious condition,gun of torch and
workpiece can collide by faster speed. After user set this parameter, when arc voltage
exceed the value of setting, torch height will not change. It is useful to protect torch. In
genal ,we set it as 30V.
P06: The arc voltage precision of adjusting. For example, if user set the parameter as 1V, it
means when D-value between setting arc voltage and practical arc voltage is under 1V,
torch height will not be adjusted. If user set the parameter as 3V means when D-value
between setting arc voltage and practical arc voltage is under 3V, torch height will not be
adjusted.
P07: Sensitivity coefficient. When arc voltage is changing, more and more bigger parameter
can make torch adjust become more and more faster. But if parameter is too big, torch is
easy to quiver around the balance location. If parameter is too small, torch can has slow
follow speed. In genal, we set it as 6. When user use it, it can be adjust on the basis of torch
effect.
Unique Solution WWW.ARCBRO.COM
20
Service Support Spirit
P08: The time of torch rise spear urgently. During torch do not work , when torch collide the
steel, THC can use fastest speed rise spear urgently in this time.
P09,P10: Setting the function of arc voltage auto adjust. During torch is cutting, because
of the arc voltage that user set is too low, or with service life of plasma pierce is decreasing,
arc voltage in plasma power source can rise. If arc voltage value of setting is invariant,
height will drop and it even can collide pierce after auto height control. During torch is cutting,
when collision has happened, if user want to make torch promote some height and continue
to cut, This function will be used by user. According to this function, THC can increase arc
voltage value of setting automatically and increase torch height after collision happen twice.
It can avoid torch continue collide pierce. During torch is cutting, when collision has
happened, if user want to make torch promote some height and continue to cut, this
function will be forbidden by user.
P11: The time of allowing collision happen during torch work. During torch is cutting, if user
allow torch continue to cut after collision has happened, user can set the time of allowing
collision happen by changing this parameter. For example, user set the parameter as1. Then
during torch is cutting, when first collision happen, THC can not send collision signal to
CNC. But THC can make torch promote a IHS height automatically. When collision happen
again, THC can send collision signal to CNC. After CNC receive this signal, torch stop to
work. In other example, user set the parameter as 3. After collision happen at the fourth time,
THC send collision signal to CNC and the input is TO CNC COLLISION.
P12: Switching motor contrary or plus direction of rotating. If user develope direction of
motor and the button of lifting/descending is different, they enable this parameter will
change direction of motor. For example, when user set P12 as 1, if the button of lifting is
pressed, motor will descend. When user set P12 as 0, if the button of lifting is pressed,
motor will lift.
P13: Enable the proximity switch collision test. When user set it as 1, THC can use the
proximity switch to test collision. When user set it as 0, THC can not use the proximity switch
to test collision. When user set it as 1, user need make proximity switch put in THC and
ensure that proximity switch is not breaking away from. Otherwise, lifting motor can rise
straight because of THC can not receive the collision signal.
to work. This parameter is bigger, deceleration can become faster, the time of motor stop
work can become shorter. The biggest parameter is 50.
P15: Reversion acceleration. Speed adjust step and length when motor turn contrary. When
motor speed is changing or motor turn positive become turn contrary. It can change speed
value by change this parameter, the bigger parameter can make reversal transition speed
become more and more smaller. We set it as 100(it is the biggest value), user can adjust
this parameter on the basis of specific condition when they used THC.
P16: Arc voltage delay time of setting. After arc start command is send and delaying in this
time has finished, THC start sampled the arc voltage value. This time can be used for
avoiding to sample severe and waved arc voltage when arc start to work.
P17: Torch lifting time after starting up. When THC is starting up, the time of promoting the
lifting motor. It can avoid some condition that the distance between torch and workpiece is
nearer. If user do not pay attention to make equipment start to work and move the torch, it
will lead to happen collision. Lifting torch can avoid this accident happen after starting up.
P18: The time of promoting the spear after torch has accomplished. After torch has
accomplished, torch can lift a height. When arc start test, if user loosened the button named
【ARCON TEST】, torch can lift in this time.
P19: Torch lifting time when arc start to work. When piercing delay time is not set to 0, THC
can used this parameter and send a commend of arc start. Arc start is working, at the same
time, torch is lifting in this time. Before piercing has accomplished, torch can descend a
height which it is the same with promoting height. It can named dynamic pierce function
similarly. When piercing is working, torch need promote a height, it can avoid dress get into
torch head. If dynamic pierce lifting times that we set is 0, torch can not promote when arc
start is working.
P20: The time of descending rapidly during the dual speed IHS. During the dual speed IHS,
at first, motor descend by fastest speed in this time. Then motor descend by lowest speed
until collision has happened(lowest speed= fastest speed /4). If user set it as 0, motor will
descend by fastest speed/4.
Note: Default of motor limit L06、L07 is Set up as 1, it means motor limit switch should be
set as shut form. User can change it on the basis of actual condition. If lifting motor do not has
limit switch, it do not connect line but they need set L06、L07 as 0.
This system adopts the integrated motor driver chip with protection function, it has perfect
over-current, Over temperature protection.
The current peak of motor drive can be up to 5A.
THC has voltage divide pierce in their interior, with CNC、dc motor、arc start switch、proximity
switch, etc. Points linking piece put in the case, and the whole point of metal shielding
encapsulation, voltage divide piece can be connected directly to the plasma power source arc
pressure and protective cap collision detection circuit, etc.
THC connect with the CNC by a socket which has 10 pin,the diagram below pin definition:
Warning:
1. The signal which connected with CNC is insulated by optocoupler , and the effective level
is low (user can change it to make high level effective)
THC use dc 24V to provide voltage, the biggest power supply scope is 22V-34V, the power
of dc 24V is depended on the motor power, the power of dc supply should be greater value-
added between motor power and 5W.
THC connect arc start switch and proximity switch by a socket which has 5 pin.
Arc Start Port This is normally open contactor of relay. When CNC send arc
3.4, 3.5 (ARCSTART_1, start commend, the contactor can close and plasma power
ARCSTART_2) source start make arc start work.
Arc start port use normally open contacts of relay: during arc start and torch are working,
relay contactor can keep close. It can keep open in other condition. The relay contactor capacity
is 10A/250VAC, if work voltage and work current of arc start control circuit are exceeded this
rated value, please use relay to augment capacity. Otherwise, system will not work steadily.
In side THC, A 200mA recoverable fuse is installed at the power supply of proximity switch,
to avoid damage of power when proximity switch failed.
The proximity switch of THC is NPN(or PNP) type open-drain proximity switch. User can set it
by the switch on voltage divide board. If the 2-bits switch is “ON”, user should use NPN proximity
switch. If the 2-bits switch is “OFF”, user should use PNP proximity switch. The default set of
the 2-bits switch is “ON”.
NOTICE: in the new version of hardware, the 2-bits switch is canceled. User can use NPN or
PNP type open-drain proximity switches directly only by changing the “L09” parameter if needed.
Figure 3.7 The proximity switch view upon voltage divide board
Figure 3.8 The proximity switch view upon voltage divide board
Warning:
THC has a function which can make firmware procedure upgrade. User can use USB flash
disk, make it connect this USB port, then it can make firmware procedure upgrade.
The upgrade method:
1) Copying the firmware program named “pthc. bin” or “F1621.bin” to the root
directory of USB flash disk.
2) Power off THC, and then insert this USB flash disk.
3) Power on THC. After THC power on, the green nixie tube may display
4) “PHC”, the red nixie tube has 3 seconds countdown. Before the end of the countdown,
pressing the button named【MENU】can enter into the upgrade mode. At the same
time, the green nixie tube can display “UPD” and start flashing, it means THC wait
for confirmation to upgrade. If user do not press the button named【MENU】before the
end of the countdown, THC will start work normally after the end of the countdown. If
user do not press the button named【MENU】before the end of the countdown, and
user presses the button named【+】, THC will skip the countdown and enter into the
normal working condition.
5) When the button named【MENU】is pressed, after entering into upgrade model, the
green nixie tube display “UPD” and start flashing, it means THC wait for confirmation
to upgrade. Then if the button named【OK】is pressed, THC start update. At the same
time, the green nixie tube display “UPD” but it do not start flashing, the red nixie tube
display upgrade progress by digital form. When it display 8, it means program has been
updated by 8%. When it display 16, it means program has been updated by 16%.
6) After pressing the button named【MENU】and THC has entered into upgrade model,
If user do not press the button named【MENU】and user presses the button named
Portable THC (TYPE F1621) use voltage divide board to detect plasma arc voltage and torch
remaining cap collision signal. The connection as follows:
ELECTRODE port(the screen printing word named ELECTRODE in PCB) connect with
plasma arc voltage cathode.
WORK port(the screen printing word named WORK in PCB)connect with plasma arc
voltage anode.
Unique Solution WWW.ARCBRO.COM
37
Service Support Spirit
SHIELD port(the screen printing word named SHIELD in PCB)connect with torch retaining
cap collision detection wiring.
The plasma power source anode is connected with GND, cathode is connected with torch
nozzle, and the voltage of nozzle is negative voltage. During torch work, the absolute value of
the arc voltage is greater than 100V. Because voltage is higher and interference is bigger, it is
necessary to control by quarantining voltage divide. THC voltage divide board use voltage
divide circuit which ratio is 100: 1, the arc voltage range which we can measure is 0V~660V.
Warning: the plasma power arc voltage sampling cable need use HVSC, plus-n-minus
should not be connected contrary. If arc voltage plus-n-minus is connected contrary, auto height
control will not work. Plasma power source arc voltage wiring need connect with wiring pile in
plasma power source output, it do not connect with torch and work piece, it can avoid disturbing
by the high frequency.
5) When torch retaining cap contact with workpiece, tangent resistance <20kΩ.
Otherwise, torch retaining cap collision detection circuit can not work because
of impedance is too large. It is especially important for rusty steel note, if the
steel rust is serious, user should clean the steel surface before torch start work,
remove rust layer.
6) Torch retaining cap collision detection circuit just need a signal line of collision
detection, circuits use wiring which arc voltage sample, so it can save a high
voltage cable.
Warning: Torch retaining cap collision detection circuit and the proximity switch detection
circuit can work at the same time, one of them can complete positioning when they has detect
collision signal. In genal, torch retaining cap IHS signal can be triggered at first and accomplish
fixed position. But when workpiece has rusted oxide or has the protective insulation, torch
retaining IHS is invalid. If torch retaining cap IHS can not complete, THC will use proximity switch
to complete positioning.
If the wiring of torch retaining cap IHS is connected true, torch retaining cap IHS will work
usefully. And user can choose whether use proximity switch on the basis of parameter. When
user set parameter P13 as 1, they should use proximity switch to detect collision. When user set
P13 as 0, they should not use proximity switch to detect collision.
During THC work, user can encounter some problem and solution as follows:
Failure
NO. Reason Solution
phenomenon
Nixie tube do Power source module Check whether the power source connection
1.
not display has problem is steady.
1. Check whether UP_LIMIT/DOWN_LIMIT
Motor do not Blocking signal make
2. signal make it lock 2. Over-current protection
turn it lock
make motor driver chip lock.
After motor Motor chip is 1. Check whether mechanical structure is
3. turn, it do not protected by over- stuck
work current action.
1. Check whether proximity switch wiring is
connected well, check whether parameter
P13 、 L09 or L08 is set well. If wiring is
After THC connected true and parameter is set true, the
Collision signal can
power on, the red indictor is lighted when proximity switch
4. make motor rise all
motor has close 2. Check whether proximity switch is
the time
been rising damaged 3. Check whether torch retaining
cap positioning wiring is connected well. In
genal, there do not has collision signal when
torch retaining cap do not contact with steel.
1. Check whether the grounding is true. 2.
Arc voltage
Check whether plasma power source cooling
5. control is
water is oozed. 3. Sensitivity coefficient P07
unstable
setting is too large
Before IHS has Extend CNC positioning waiting time
accomplished,
It always happen in
plasma can
6. the case of arc start
make arc start
signal control
work right
away
The THC will produce some common fault alarm signals during use. For example, collision
signals, motor limit alarm signals, etc., the program itself will record these faults, And display
on the screen or digital tube in the form of alarm code.
After-sales engineers or customers themselves can quickly judge the fault status of the
height controller through these alarm codes, or query the fault alarms that have occurred
recently, without repeated testing, and improve the efficiency of problem solving.
Features:
1. In the case of power supply, THC can save the last 10 alarm codes.
2. There is no need to manually clear the alarm code. After the fault is eliminated, the alarm
code will be automatically eliminated.
3. When multiple alarms occur at the same time, the alarm code can be displayed
cyclically.
4. THC has added a historical alarm record interface to facilitate user inquiries.
5. The history record can be cleared through the newly added P34 parameter.
5.1. Description:
1. After powering on, you can press the "Menu" button 4 times to enter the alarm code history
record interface, as shown in the figure below.
You can use the "+" and "-" buttons to switch the serial numbers 01-10 to view the last 10 alarm
codes saved.
Unique Solution WWW.ARCBRO.COM
45
Service Support Spirit
2. When THC has an error, the main interface will display Err + alarm value. After troubleshooting,
the alarm code will automatically disappear.
Please refer to the figure below for alarm examples.
3. If you want to clear the last 10 saved alarm codes, you can switch to the P34 parameter
through the menu button and change its value from 0 to 1.
Location detection
6 E05 Reserved.
timed out
Arc detection
7 E06 Reserved.
timeout
8 E07 Arc breaking alarm Check the cause of Plasma the broken arc.