Commands
8.3 Command groups of SIWAREX WP521/WP522
Command Command Description
code 715 B Process value Show gross process weight on the main display 716 B process value after first filter Gross process weight after the first filter
1001 Set to zero Zeroing (semi-automatic) 1011 Tare Taring (semi-automatic) 1012 Delete tare Delete current tare weight 1013 Valid tare Activate default tare 1016 SIMATIC tare specification Specified tare weight from SIMATIC I/O interface
8.3 Command groups of SIWAREX WP521/WP522
The following commands can be triggered in the scale data block DB_SCALE in the area CMD1 to CMD3:
Table 8- 5 Command groups of SIWAREX WP521/WP522
Command group Description
1 ... 999 Commands are passed by the function module to the module via data record DR 2 (scale, weighing, display, trace commands). The meanings of the commands correspond to the command list (see → Command lists (Page 133)). 2000 + X Reading of a data record, X corresponds to the data record number. Example: Data record 3 transmitted by SIWAREX module to SIMATIC CPU → 2000 + 3 = command code 2003 4000 + X Writing of a data record, X corresponds to the data record number. Example: Data record 3 transmitted by SIMATIC CPU to the SIWAREX module → 4000 + 3 = command code 4003 7001 Read all data - Read all data from the SIWAREX to the CPU 7002 Write all data - Write all data from the CPU to the SIWAREX (service mode has to be turned on)
Additional information on transmission of commands from the control program by means of
the SIMATIC interface is available in chapter Communication with SIMATIC S7-1500 (Page 137).