FL 10 Diaphragm Liquid Pump: Advantages Possible Areas of Use
FL 10 Diaphragm Liquid Pump: Advantages Possible Areas of Use
FL 10 DC-P FL 10 AC
www.knf.com
ex
t -e
ib l
e•c •c
u st o m - f i t
PERFORMANCE DATA
Series model FL 10 DC-P 24 V FL 10 AC 230 V/50 Hz FL 10 AC 115 V/60 Hz
Material options KP KT
Pump head PP PP
Diaphragm PTFE PTFE
Resonating diaphragm EPDM FFKM
Valves EPDM FFKM
Flow rate at atm. pressure (ml/min) 100 +/-10ml/min 90 +/-10ml/min
Suction height (mWg) 2 1.5
Pressure head (mWg) 10
Permissible ambient air (ºC) -5 to 60
Permissible liquid temperature (ºC) 5 to 80
Weight (g) 173
IP protection factor 65
ELECTRICAL DATA
Operating voltage (V) 24 230 115
Power consumption (W) 7.7 7.1 5.8
Operating current (A) 0.87 0.1 0.18
1
FL 10 DC-P FL 10 AC
PERFORMANCE DATA PERFORMANCE DATA
Series model Flow rate at Max. Max. Series model Flow rate at Max. Max.
atm. pressure suction pressure atm. pressure suction pressure
(ml/min) height head (ml/min) height head
(mWg) (mWg) (mWg) (mWg)
FL 10 KP DC-P 100 +/-10ml/min 2 10 FL 10 AC 230 V 100 +/-10ml/min 2 10
FL 10 AC 115 V 90 +/-10ml/min 1.5 10
FL 10 DC-P FL 10 AC
Recommendation fastening screws: Recommendation fastening screws:
self-cutting Ø 3 mm self-cutting Ø 3 mm
Dimensions in mm Dimensions in mm
120
50 Hz
100
Flow rate [ml/min]
80
60
25 Hz
40
10 Hz
20
0
-2 0 2 4 6 8 10
E195_2017-03-20_Förderkurve_DC_Datenblatt_C2_T.FO.0014
Diagr. Verkauf E Erstellt: Erstelldat / Ersteller
2
OPTIONS
Description Illustration Details
Drives Various voltage options
ACCESSORIES
Description Illustration Details
Elastomer mounting kit For easy and vibration dampening mounting of the
pump in the customer system.
Diaphragm pressure control valve The pressure control valve can be used for a more
accurate control of flow against a fluctuating back
pressure, metering into a vacuum and from a
pressurised system.
The performance values for the series If individual designs have been created for
models shown on this data sheet were specific customers on the basis of series
determined under test conditions. models, other technical performance data
The actual performance values may differ may apply.
KNF 06/2021. www.knf.com
and depend in particular on the usage Before operation begins, the relevant www.knf.com
conditions and therefore on the specific operating instructions and/or assembly or
application, on the parameters of the installation instructions should be read and
components involved in the user’s the safety information contained in these
without notice.