INTRODUCTION

Installation
Thank you for purchasing a Belkin Uninterruptible Power Supply
Note!
(UPS). Each year, several natural and man made occurrences put
the power supplied to your electronics in your home or office in Before installation, please inspect the UPS Upon receipt.
jeopardy. At risk are your hardware, software and data because of Make sure that the UPS is not damaged.
these power problems.
Connect to AC Utility Power
IMPORTANT SAFETY INSTRUCTIONS FOR MODELS Connect the AC inlet to utility power via the power cord.
F6C800-UNV Check whether the Site Wiring Fault indicator is lit or not. If
Please save this manual! F6C100-UNV
It contains important operating instructions and warranty F6C120-UNV so, please check the utility wiring.
information pertaining to your UPS.
Charging the Battery
Please save or recycle the packaging materials! For best results, charge the battery for 6 hours prior to initial use. The
The UPS packaging was designed with great care to provide UPS must be turned on to charge. The UPS charges its battery
protection during shipment and delivery. These materials are whenever it is connected to the utility power. Should you see the red
invaluable if you ever have to return the UPS for service. Damage
battery light come on, the battery may need immediate charging.
sustained during transit is not covered under the warranty.

Federal Communications Commission Interference Statement Plug in Power Devices


This equipment has been tested and found to comply with the Plug your devices into the AC outlets on the top of the UPS. To use the
ALARMS
limits for a Class B digital device, pursuant to Part 15 of the FCC UPS as a master on/off switch, make sure all of the loads are switched
Rules. These limits are designed to provide reasonable protection Battery BACK UP (Slow Alarm) on.
against harmful interference in a residential installation. This When in the UPS is in battery BACK-UP mode, the On Battery (Yellow Caution: Never connect a laser printer or scanner
equipment generates, uses and can radiate radio frequency LED) illuminates and the UPS sounds an audible alarm. The alarm stops to the backup outlets of UPS with other computer
energy and, if not installed and used in accordance with the when the UPS returns to normal ON LINE operation. equipment. A laser printer or scanner draws
instructions, may cause harmful interference to radio significantly more power when in use than when
communications. To assure continued compliance, use only
Low Battery (Rapid Alarm) idle. This may overload the UPS.
shielded interface cables when connecting to computer or
peripheral devices. Any changes or modifications not expressly When the UPS is in battery BACK-UP mode and the battery energy
Laser Printer
approved by the party responsible for compliance could void the begins to run low, the UPS will beep rapidly until it shuts down from a Turning on the UPS
user’s authority to operate this equipment. Turn on your UPS by pressing and holding the On/Off/Test button for
depleted battery or returns to ON LINE normal operation.
approximately 3 seconds until the “ON LINE” Green comes on. The
CONTENTS OVERLOAD (Continuous alarm) UPS will perform a self-test each time the UPS is switched on.
You should have received the following: Note! The UPS maintains the battery charge when in the off
When the UPS is overloaded (the connected loads exceed the maximum
1 – UPS unit position and will respond to commands received through the
rated capacity), the UPS emits a continuous alarm to warn of an overload
1 – Bulldog Plus Shutdown Software computer interface port.
1 – USB Cable condition. Disconnect nonessential equipment.
1 – Serial Cable from the UPS to eliminate the overload.
1 – Phone Line Cable Turning off the UPS
FAULT (10 Seconds Continuously) Turn off the UPS by pressing and holding the On/Off/Test button for
UPS FEATURES AND FUNCTIONS When the output is shorted, the UPS emits a 10 seconds continuous more than 3 seconds until the “ON LINE” or “ON BATTERY” LED goes
Before installation, please inspect the UPS upon receipt. Make alarm to warn of a short condition. Disconnect the equipment from the off.
sure that nothing is damaged. UPS prior to checking the equipment.
Rear Panel To Conduct a Self Test
Use the self-test to verify both the operation of the UPS and the
Internet/ condition of the battery. In normal utility power, push the On/Off/Test
Interface Port
Phone/ Fax/
ON LINE
DSL and
(RS232 Port) button less than 2 seconds and the UPS performs a self-test function.
ON BATTERY
Network
Site Wiring
During the self-test, the UPS operates in back-up mode.
Protection Note! During the self-test, the UPS briefly operates on- battery
Fault Indicator
Interface Port backup power (the on-battery LED comes on). If the UPS passes
FAULT /
(USB¡@Port) the self -test, it returns to on-line operation. If the UPS fails the
* OVERLOAD /
* REPLACE self-test, it immediately returns to on-line operation and lights the
BATTERY Battery Back
up outlets
replace battery LED. The loads are not affected. Recharge the
AC Input
battery overnight and perform the self- test again. If the replace
ON / OFF / TEST Breaker battery LED is still on, the battery will need to be replaced.

To Silence Audible Alarm


Surge-only While in battery BACK-UP mode, push on/off/test button less than 2
Protected AC Input seconds to silence the audible alarm. (This does not work if the UPS is
Your UPS features 3 LED indicators which specify’s certain Outlets Power Cord
under LOW BATTERY or OVERLOAD condition.
functions on your UPS. Please review the Front Panel diagram
and with this chart, as it will assist you in the use of your UPS. All equipment must be turned off prior to hardware installation.
INTERNET/PHONE/FAX/DSL/NETWORK PROTECTION
Indicator Condition Meaning Connect the phone/fax/modem/network lines
The internet/phone/fax/DSL/network lines are surge protected and provide
Connect a single Internet/ phone/ fax/ DSL/network line into the surge-
ON LINE _ Solid Green AC Power is on complete safety for line connection.
protected sockets on the back of the UPS. The RJ-11/RJ-45 modular
(Green LED) _ Flashing Green AVR is active sockets accepts standard single line telephone connections. The
INTERFACE PORTS
connection will require another length of telephone cable, which is
This condition for the On- The UPS provides both a USB and RS232 port for you use with your
Battery LED can indicate 1 supplied.
computer. NOTE: Choose one port only.
of 2 problems:
1. The UPS is on battery
backup and an BATTERY BACK UP OUTLETs
_ Flashing Yellow intermittent audible alarm
ON BATTERY Only data sensitive equipment such as a computer, monitor and external IN OUT

LED with Audible is on. The UPS will begin


(Yellow LED) shutdown procedure. drive should be plugged into these outlets. Battery power is automatically
Alarm (Beeping) provided in case of a power outage. Power (AC or battery) is not supplied
2. Bat te r y is lo w. T he UPS to these outlets when the UPS is switched off. (Do not plug surge Telephone Phone
Socket
will sta rt sh ut d own. T he Modem/ Fax
protectors or power strips into the battery back up outlets).
b uzze r sou n ds a n a ud ible
a la rm . Note! This connection is optional but highly suggested as Internet/
The Fault/Overload can SURGE-ONLY PROTECTED OUTLETS
phone/ fax/modem/ DSL/network lines often carry dangerous surges
indicate 1 of 2 problems. Equipment such as a printer, fax machine, scanner, or a desk lamp can be
and spikes. The UPS works properly without a phone/ fax/ modem /
1. There is a problem with plugged into these outlets. These outlets do not provide power during a
the UPS. The LED will DSL connection.
power outage. These outlets are always on (when AC power is available)
be lit continuously, and Caution! The Internet/ phone/ fax/modem/ DSL/network protection
& are not controlled by the front panel switch.
_ Solid Red the unit will sound an feature could be rendered inoperable if improperly installed. Make sure
FAULT/
audible alarm for 10 that the telephone line from the wall is plugged into the connector
*OVERLOAD/ seconds. AC INPUT BREAKER (CIRCUIT BREAKER)
marked “IN”, and the device to be protected is plugged into the connect
*Replace The circuit breaker button will be triggered if an overload condition forces
2. Battery is weak or bad, or marked “ OUT”.
Battery the battery needs to be the UPS to disconnect itself from utility power. If the button sticks out,
replaced. disconnect nonessential equipment and depress breaker. Serial or USB Communication Port (Installation Optional)
To fully utilize the Bulldog Shutdown Software; you will need to connect
Battery output is drawing the UPS to your computer.
_ Flashing RED more power than the UPS SITE WIRING FAULT INDICATOR
can provide. The Site Wiring Fault LED will illuminate when one of the following The communication port will provide the following features:
conditions exist: 1. Monitoring charger status
SITE WIRING There is either no ground 1. Open or high-resistance ground 2. Monitoring UPS status
FAULT circuit or a reversed 2. Hot and neutral polarity reversal
_ Solid Red 3. Monitoring battery status and condition
(ON REAR polarity in the building
3. Overloaded neutral circuit 4. Monitoring the utility status
wiring.
PANEL)
System Requirements 5. Use the ON/OFF/TEST UPS power switch function to schedule
The UPS can be used without the software and can be used with any 6. UPS for power saving
computer using upto a 21” monitor or a flat panel screen. Also, you do not
have to have the software installed to utilize the battery backup outlets. You may connect the UPS to your computer by choosing either the
Serial or USB ports. Note: Choose one port only. Do not connect
To fully utilize the UPS and its software, your computer must be able to your computer through both ports.
operate the following operating systems: 95/98/ME/NT4/2000/XP & Novell

3.X & Higher and have a Serial or USB port.


LICENSE: You have the non-exclusive right to use the software.
1. From the “Welcome to the Belkin Bulldog Plus Product Installation You are not permitted to copy, modify or transfer the software or
Browser” window, locate and choose User Manual’s.
documentation. You may not compile, disassemble or otherwise
2. The “ Bulldog Plus User Manuals” window will appear. Please move reverse engineer, breakdown, analyze or modify the software.
your pointer to the manual you wish to open and click. USE AND RESTRICTIONS: You are permitted to make backup copies
RS-232
of all the software disks for archival purposes only. You must
Connector 3. An Adobe pdf file will be opened. To save a copy to your hard drive,
reproduce the proprietary notice set forth on the disks and affix them to
you will need to goto “File” on your menu bar and choose “Save a
copy”. all backup copies. You are not permitted to use these programs in
connection with
4. On the Save a Copy window, please choose a destination folder for a computer service, or to use the backup copies other than as a
the manual. replacement for the original copy.
I) Uni nstal l for Wind ows 9 5/98/ Me/NT 4/200 0/XP TERM: This license is effective upon acceptance by opening this
The re ar e two options t o uninstall the Belkin Shutdo wn So ftwar e. envelope or in any other way using the enclosed software, which will
Opt ion 1 constitute your acceptance of, and agreement to, this Agreement, and
USB 1. Click th e Sta rt icon in the lower left hand corn er of your scre en an d got o
Connector is effective until terminated. The limited license in this Agreement will
the Prog rams folde r. Scroll to th e Belkin Bulldo g Plu s folder and ch oose
set up. Insta ll Wizard will appea r. be automatically terminated if you fail to comply with any of the Terms
Using the serial or USB cable (provided), connect the cable to your and conditions in this Agreement. You agree that upon such
UPS then connect the other end to the USB port on your computer. 2. Cho ose Remove and click Next . termination
Caution: Use only the factory-supplied UPS monitoring cable. you will immediately destroy all programs and documentation, including
3. The Prog ram Files and Audio Files will be checke d. If they are not,
ple ase check them. Click Next. Th e uninstall pro cedur e will beg in. all copies made or obtained by you.
USB : HID Windows Setup Procedure SOFTWARE, PROGRAM, DOCUMENTATION, AND ANY RELATED
1. When the USB cable is first connected to a USB port on your 4. Click Finish when complete. INFORMATION, GOODS OR SERVICES ARE PROVIDED WITH NO
computer, the Windows® 98 dialog called ADD NEW WARRANTY OR REPRESENTATION OF ANY KIND WHAT SO EVER.
HARDWARE WIZARD should automatically appear. (To display Opt ion 2
BELKIN HEREBY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS
this dialog manually, click the START button and choose (No te: Windows XP users, cho ose the Co ntrol pane l fun ction from your
Sta rt icon an d the n got o to step 2.) OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED
SETTING to access the control panel, and double-click on ADD
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
NEW HARDWARE.) 1. Click th e Sta rt icon in the lower left hand corn er of your scre en an d got o PARTICULAR PURPOSE.
2. The ADD NEW HARDWARE WIZARD will guide you through the Sett ings icon. Goto and choose the Cont rol Panel folde r. Th e Con trol The entire risk of the use, results and performance of the software,
the installation process. Click Next. Pan el window will appea r.
program and documentation is borne by you. Should any or all of the
3. A dialog states, “Windows will now search for any new Plug-
2. Locate a nd click t he Add /Remo ve Pro grams icon . The Add /Remo ve product, software, program, documentation, or related information,
and-Play devices on your system.“ Click Next.
Pro grams wind ow will ap pear. goods or services be defective, misused, unsuitable or cause or give
4. A subsequent dialog gives you these options: “Search for the
best driver for your device (recommended) and display a list of rise to any harm or liability whatsoever, you, not Belkin or its
3. Locate and ch oose the Belkin Bulldog Plus softwa re. Click the
all drivers in specific location. This enables you to select the associates, dealers or agents, assume the entire liability, cost of repair,
Cha nge/Remove butt on on the right . Install Wizar d will app ear.
driver you want. “Please accept the recommended choice by correction
clicking NEXT. 4. Cho ose Remove and click Next . or any payment or other remedy whatsoever. Furthermore, no
5. The Wizard will then search your hard drive for a file called warranty or guarantee is made regarding the use or results of the
5. The Prog ram Files & Aud io Files will be che cked. If they are no t, please product, software, program, documentation, or any related information,
“\INF\ hidden.inf”. This file contains all the information that
che ck th em. Click Next. The uninstall proce dure will begin .
Windows® OS needs to install the correct device drivers. goods or services in terms of correctness, accuracy, reliability,
6. The wizard might ask for the Windows OS CD-ROM. Place the 6. Click Finish when complete. timeliness or otherwise. You use and rely on the program at your own
CD into the CD-ROM drive & select OK. risk. The following is the only and exclusive warranty and remedy of
7. The installation process will continue to run until a dialog Please visit belkin.com for the latest software upgrades and information any kind: Belkin does warrant that the program disks are free from
display shows that the drivers have been installed. Select the on your belkin ups. physical
FINISH button and your drivers are installed. defects in materials and workmanship under normal use for a period of
TECHNICAL SPECIFICATIONS
one (1) year from the date of purchase, as evidenced by a copy of the
G) Install the Software (Optional) F6C120-
a)To fully utilize the UPS and its software, your computer must be MODEL F6C800-UNV F6C100- UNV sales receipt. Return the defective disk or documentation with your
UNV
able to operate the following operating systems: 95OSR2 / 98 / receipt directly to Belkin for a replacement.
ME / NT4 /2000/XP & Novell 3.X & Higher and have a USB port. 1000VA / 1200VA DISCLAIMER: Belkin or its associates will in no event be liable (i) in
Capacity 800VA /450W
550W /670W any amount for lost profits or special, incidental, punitive or
b)Your UPS features the Bulldog Plus Shutdown Software. This INPUT Voltage
90-136Vac consequential damages, or (ii) for any claim or damage of any nature,
allows you to protect and save your data should a power outage Range
occur, as well as safely shutdown your computer in your or under any theory, whatsoever, in any amount in excess of the
absence. Please be sure to close out of all applications prior to Frequency 60HZ ( ±3HZ ) purchase price you paid for the product. The warranties and remedies
installing the software. Voltage Simulated sine wave, 120vac±10% here set forth are exclusive, and in lieu of all others oral or written,
OUTPUT Frequency express or implied. Some jurisdictions do not allow exclusion or
1. To install the software, please place the CD into the CD drive ( on battery) 60HZ ( ±1HZ )
of your computer. limitation of implied warranties or of liability for incidental damages, so
Back up time
Full / half 3-8 min 3-8 min 3-7 min the foregoing limitations or exclusion may not apply to you. This
2. Your computer should autorun the CD. If this does not occur, load warranty gives you specific legal rights, which vary from jurisdiction to
go to the Run feature on your Start icon (lower left corner) on BATTERY Typical jurisdiction.
your screen. Please enter the CD drive, it may be D: Upon Recharge _ 12hours recover 85% capacity
Time HOWEVER, YOU WAIVE SUCH RIGHTS, EXCEPT AS EXPRESSLY
entering the drive Run setup.exe. to execute the software.
Should you continue to have a problem, please refer to your Ambient PROVIDED UNDER THE TERMS AND CONDITIONS OF THIS
ENVIRONMENT 0~85% humidity non-condensing, 0~35_
computer’s owner’s manual for the correct drive. operation AGREEMENT, TO THE MAXIMUM EXTENT ALLOWED BY LAW.
Safety UL / C-UL, meet FCC class B The license is governed by the laws prevailing in the State of New
3. The “Welcome to the Belkin Bulldog Plus Product Installation CONFORMANCE Meet IEEE C62.41 Category A standard,
Surge York, without regard to its conflicts of laws principles.
Browser” will appear. Please click Install. 890Joules.
Dimension 120mm X 300mm X 190mm (4.72” X 11.81” ACKNOWLEDGMENT:
4. Upon clicking Install, the Bulldog Plus Installation window will (W X D X H) X7.48”) By opening the package on which this Agreement is printed, or through
PHYSICAL
appear. Please choose the appropriate software to install Net weight 11.4KGS/25.13 13KGS/28.6 13.5KGS/29.7 which it is visible, you acknowledge that you have read this Agreement,
LBS 5LBS 5LBS
understand it, and agree that this agreement is the complete and
5. InstallShield Wizard will appear onscreen, click Next. All specifications are subject to change without prior notice. exclusive statement of agreement between yourself and Belkin and
STORAGE supersedes any prior agreements, oral or written, and any other
6. Please read the License Agreement and click Yes.
Storage Conditions communications relating to the subject matter of this Agreement.
7 On Setup Type, ALL (Standalone) is the default. Standalone is Store the UPS covered and upright in a cool, dry location with its battery SEVERABILITY:
for UPS management for your computer only. Networking fully charged. Before storing, charge the UPS for at least four hours. Any term or provision of this Agreement or any application thereof,
management is for administrators who need to manage which may be prohibited or unenforceable by law in a particular
Disconnect any cables connected to the computer interface port to avoid
several UPSes in a workstation environment. You should not
install the networking files unless you are technically qualified unnecessary drainage of the battery. jurisdiction, shall be interpreted and enforced to the maximum extent
to use these features. For more information on networking, Extended Storage allowed in such jurisdiction (which the parties acknowledge could mean
please refer to the software user’s manual. During extended storage in environments where the ambient temperature severing the provision from this Agreement or, if allowed, enforcing it in
is +5 oF to +86 oF, charge the UPS battery every six months. During a narrower form), without affecting the remainder of this Agreement, or
8. On Choose Destination Folder, you have the option to choose
extended storage in environments where the ambient temperature is +86 any other application of such term or provision in such jurisdiction, or
the location of where you would like the Software located on o o
your computer. We recommend using the default option as F to +113 F, charge the UPS battery every three months. application of such term or provision in any
shown on screen. To use the default option, click Next. Note: Safety Information
CAUTION!
9. On Select Program Folder, you have the option to choose the
program folder for your Software. We recommend using the l Internal battery voltage is 12V DC.
default option as shown on screen. To use the default option, l The unit is intended for installation in a controlled environment
click Next. Belkin Components User License Agreement (temperature controlled, indoor area free of conductive
Away from sunlight Away from heat Away from water
contaminants).
10. On the Select Language screen, please select your language Belkin Components (Belkin”) thanks you for choosing one of our products. l All batteries used are Sealed Lead Batteries. Batteries must be
choice. This User License Agreement (Agreement”) contains the terms and recycled.
11. The software will now be installed. Once completed, please conditions under which limited use of the product is licensed to you. Recycling Information
click Finish. PLEASE READ THIS NOTICE CAREFULLY. DO NOT USE THE Your UPS contains a Non-spillable Sealed Lead Battery. On the
SOFTWARE OR PRODUCT UNTIL YOU HAVE READ AND AGREED TO battery, you will find the battery name. Please reference the chart
Note! THIS AGREEMENT. IF YOU USE THE SOFTWARE AND PRODUCT,
Please refer to the help feature found on the Belkin On-line Screen. below for recycling information.
YOU ARE AGREEING TO THE TERMS AND CONDITIONS SET OUT IN
To access this screen, please click the Belkin shield found in the Battery Name Recycling Inside Recycling Outside
lower right corner on your task bar of your screen. THIS AGREEMENT. IF YOU DO NOT ACCEPT THESE TERMS AND
the USA the USA
CONDITIONS, YOU MUST RETURN THE UNOPENED PRODUCT WITH
Once the Belkin On-line screen appears, choose help. The Bulldog BB Battery (800) 278-8599 N/A
THE DISKS INSIDE TO THE PARTY FROM WHOM YOU RECEIVED IT.
Online Help screen will appear. You may use the Contents, Index SCOPE OF USE: In this Agreement, software means all machine- CSB Battery (800) 738-7372 1 (817) 244-4415
or Search tabs to assist you with your help issues and to get more
readable software programs and associated files in this package. All VISION Battery (973) 726-5323 N/A
information on the specific features and functions of the software.
modified versions of and upgrades or improvements to such programs
H) User Manual Installation and all copies of such programs and files. You, a single user opening this
You will need Adobe Acrobat Reader to review the User’s Manuals. envelope (You or our), may use the software on a single central
If you do not have the reader, please goto www.adobe.com to
processing unit. You may not rent it, loan it out, or lease it, nor use it on a
download a free version of the software.
multi-user system.
CONTACT US
Belkin Components, Ltd Belkin Components, Ltd
501 West Walnut St. Unit 13 • Gatelodge Close •
Compton, CA • 90220-5221 Round Spinney
USA Northampton, NN3 8RX UK
Tel: 310.898.1100 Tel: +44 (0) 1604678300 • Fax:
Fax: 310.898.1111 +44 (0) 1604678330
Belkin Components B.V. Belkin Australia Ltd
Starparc Building 7 Bowen Cresent
Boeing Avenue 333 West Gosford, NSW 2250
1119 PH Schiphol-Rijk Tel: +61 (02) 4325 4666
The Netherlands Fax: +61 (02) 4325 4277
Tel: +31 (0) 20 654 73 00
Fax: +31 (0) 20 654 73 49

Please visit www.Belkin.com for battery replacement information.


TROUBLE SHOOTING
PROBLEM POSSIBLE CAUSE SOLUTION
On/ Off /Te st but ton not Press the On/Off /Test
pushed or pushed less button for more than 3
than 3 second seconds
UPS not on,
Recharge the UPS at
LED not lit Battery voltage is too low
least four hours
Con tact service
UPS fault
per sonne l
Re-plug the power
Power cord loose
cord
UPS always AC breaker is burned out Replace or reset the
on battery or tripped breaker
mode Ac utility voltage is too
high or too low, or black Normal condition
out
Recharge the UPS at
Battery not fully charged
least four hours
Back up Remove some un-
UPS is overload
time too necessary loads
short
Charger fault or other Rep lace bat tery.
reason Con tact belkin.com
The UPS
Rem ove t he non-critical
continuous Overload
loa ds
ly beeps
Rep lace batte ry.
Red LED lit Battery failure