* Compatible Older Instrument Model: (1) UV-1200 series (2) UV-1601/1601PC/1650PC (3) UV-1700 PharmaSpec
(4) UV-2401PC/2501PC/2450/2550 (5) UV-3101/3101S/3101PC/3150 (6) MultiSpec-1500
For details about models older than those shown above or their compatibility, contact your Shimadzu sales representative.
** Corresponding product is not sold in Europe since it is not a RoHS compliant product.
*** Measurement using the Automatic X–Y Stage is not supported.
2
Compatible Instrument Model Compatible Older
Accessory P/N UV-1800 UV-2600 Page
UVmini UV-1280 UV-3600 UV-3600 Plus SolidSpec Instrument Model*
UV-1900 UV-2700
Specular Reflectance Attachment (5° Incident Angle) 206-14046-58 ✓ ✓ ✓ ✓ ✓ ✓ ✓ (1)(2)(3)(4)(5)(6) 20
ISR-2600 206-28400-58 ✓
ISR-2600Plus 206-28410-58 For UV-2600 21
ISR-240A ** 206-23860-91 ✓ (4)
ISR-3100A ** 206-23851-92 ✓ (5)
Integrating Sphere Attachments ISR-603 207-20100-58 ✓
22
ISR-1503 207-20900-58 ✓
ISR-1503F 207-21300-58 ✓
LISR-2100 ** 206-23862-91 ✓ (5)
LISR-3100 ** 206-23862-92 ✓ (5)
MPC-2600A 207-23520-41 ✓
Multipurpose Large-Sample 23
MPC-3100 ** 206-23831-91 ✓ (5)
Compartments
MPC-603A 207-23550-41 ✓
Powdered Sample Holder (for Integrating Sphere) 206-89065-41 ✓ ✓ ✓ ✓ (4)(5)
Micro Beam Lens Unit 206-22051-41 For UV-2600 ✓ ✓
Micro Sample Holder 206-28055-41 For UV-2600 ✓ ✓
Suspension and
D25 mm 207-23559-41 For UV-2600 ✓ ✓ 24
Opaque Sample
Measurement Cylindrical Sample Holders D50 mm 207-23559-42 ✓ ✓ ✓ ✓ (4)(5)
D110 mm 207-23559-43 ✓ ✓ ✓ ✓ (4)(5)
ASR-3105 206-16817-58 ✓ ✓ ✓ ✓ (4)(5)
Absolute Specular ASR-3112 206-16100 ✓ ✓ ✓ ✓ (4)(5)
Reflectance Attachments ASR-3130 206-15001-58 ✓ ✓ ✓ ✓ (4)(5)
ASR-3145 206-15002-58 ✓ ✓ ✓ ✓ (4)(5)
BIS-3100 206-17059-58 ✓ ✓ (4)(5)
Sample Base Plate BIS-603 207-21100-58 ✓
Integrating Sphere Sets BIS-3700 206-20880-51 For 3700 25
BIS-3700DUV 206-20880-52 For 3700DUV
Large Polarizer Set 206-15694-40 ✓ ✓ ✓ ✓ (4)(5)
Type I 206-13236-41 ✓ ✓ ✓ ✓ (4)(5)
Polarizers Type II 206-13236-42 ✓ ✓ ✓ ✓ (4)(5)
Type III 206-13163-40 ✓ ✓ ✓ ✓ (4)(5)
Polarizer Adaptor Set 206-15693 ✓ ✓ ✓ ✓ (4)(5)
Variable Angle Measurement For MPC-2600A 207-23490-41 ✓
26
Unit For MPC-603A 207-23490-42 ✓
Automatic X–Y Stage 206-20810-58 ✓
DDU 206-20264-51 For 3700
Direct Detection Units
DDU-DUV 206-20264-52 For 3700DUV
27
Special Purge Box 206-21788-58 For 3700DUV
Accessories for Large Specular Reflectance Attachment
SolidSpec-3700 206-20570-58 ✓
(5° Incident Angle)
Variable Angle Measurement For 100V 207-23470-41
✓
Unit For 230V 207-23470-42
Square Cell Holder for Integrating Sphere 206-22339-92 ✓
DPU-414 ** 206-55215-XX ✓ (3) 28
Screen Copy Printers
Printer, DPU-S445 207-23484-48 ✓ ✓
Interface Cable Analog Signal Output Interface 206-25233-91 ✓ ✓ ✓
USB Interface Cable 088-50602-49 ✓ ✓
Water Analysis Program See text ✓ 29
(English) 207-21250-92
LabSolutions DB Connection Kit ✓ ✓ ✓ ✓ ✓ ✓ (2)(3)(4)(5)
(Chinese) 207-21250-93
(English) 207-21251-92 30
LabSolutions CS Connection Kit ✓ ✓ ✓ ✓ ✓ ✓ (2)(3)(4)(5)
(Chinese) 207-21251-93
Optional Tm Analysis Software 206-57476-91 ✓ ✓ ✓ ✓ (2)(3)(4)
Software Film Thickness Measurement Software 206-66877 ✓ ✓ ✓ ✓ (2) (4)(5)
Color Measurement Software See text ✓ ✓ ✓ ✓ (2) (4)(5) 31
Solar Transmittance Measurement Software 206-23130-92 ✓ ✓ ✓ (5)
LabSolutions UV-Vis (English/Chinese) 207-24525-92 ✓ ✓ ✓ ✓ *** 32
(English) 207-24526-92 ✓ ✓ ✓ ✓ ***
LabSolutions DB UV-Vis 34
(Chinese) 207-24526-93 ✓ ✓ ✓ ✓ ***
3
Guide to Selecting Accessories
Solid Samples
Samples Measurement Method and Conditions Accessories
Standard Sample Compartment + Film Holder, Cell Type Sample Holder,
Less than 3 mm thick
Glass/Film Holder for Standard Sample Compartment
More than 3 mm thick Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603)
Transmittance measurement
Requires a large integrating sphere Integrating Sphere Attachment, 150 mm Dia. (ISR-1503, ISR-1503F)
(due to ISO compliance and other reasons).
Large sample size (over 100 mm square) Large-Sample Compartment (MPC-2600A/603A or SolidSpec-3700) Glass Sample Holder for MPC series/SolidSpec
Relative specular Normal measurement Specular Reflectance Measurement Attachment (5° incident angle)
reflectance
Smooth measurement Large sample size (over 100 mm square) SolidSpec-3700 + Large Specular Reflectance Measurement Attachment (5° incident angle)
Surface Absolute Specular Reflectance Attachment (ASR-3105) (Requires a Large-Sample Compartment and
Samples* 5° incident angle measurement
Absolute specular BIS-3100/3700/603 Sample Base Plate Integrating Sphere Set separately).
reflectance 12°/30°/45° incident angle Absolute Specular Reflectance Attachment (ASR-3112, ASR-3130, ASR-3145) (Requires a Large-Sample
Reflectance measurement measurement Compartment, BIS-3100/3700/603 Sample Base Plate Integrating Sphere Set, and polarizer assembly separately.)
measurement
Variable incident angle measurement Variable Angle Measurement Unit (Requires large-sample compartment and polarizer assembly separately.)
Normal measurement Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603)
Relative diffuse
Requires a large integrating sphere
reflectance Integrating Sphere Attachment, 150 mm Dia. (ISR-1503, ISR-1503F)
(due to ISO compliance and other reasons).
measurement
Large sample size (over 100 mm square) Large-Sample Compartment (MPC-2600A/603A, or SolidSpec-3700)
Normal measurement Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603)
Requires a large integrating sphere
Transmittance measurement Integrating Sphere Attachment, 150 mm Dia. (ISR-1503, ISR-1503F)
(due to ISO compliance and other reasons).
Large sample size (over 100 mm square) Large-Sample Compartment (MPC-2600A/603A, or SolidSpec-3700)
Rough
Surface Normal measurement Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603)
Relative diffuse
Sample** Requires a large integrating sphere
reflectance Integrating Sphere Attachment, 150 mm Dia. (ISR-1503, ISR-1503F)
Reflectance (due to ISO compliance and other reasons).
measurement
measurement Large sample size (over 100 mm square) Large-Sample Compartment (MPC-2600A/603A, or SolidSpec-3700)
Consult your Shimadzu representative.
Absolute diffuse reflectance measurement
(Depends on the sample. A method using conversion from the mirror reflectance, for instance, is available.)
Large sample size (over 100 mm square) Large-Sample Compartment (MPC-2600A/603A, or SolidSpec-3700)
Small sample size (below 5 mm square) Micro Sample Holder + Micro Beam Lens Unit
* Metals with a mirror-finished surface, mirrors, transparent acrylic and films, etc.
** Paper, cloth, plastics, semi-transparent films, etc.
For color measurement, the Color Analysis Software or LabSolutions UV-Vis Color Measurement Software is required separately. For film thickness measurement, the Film Thickness
Measurement Software is required separately.
Liquid Samples
Samples Measurement Method and Conditions Accessories
Sample volume: 2.5 mL min. Standard Sample Compartment + 10 mm Cell
1 mL min. Semi-Micro Cell + Micro Cell Holder with Mask
500 μL min. Micro Cell + Micro Cell Holder with Mask
Micro-volume measurement
50 μL min. Super-micro Cell + Super-micro Cell Holder
For automatically measuring samples in multiple cells MMC-1600 8/16 Series Micro Multi-Cell Holders and Cells
Samples with high absorbance, but that are difficult to dilute (short optical path measurement) Short-Path Cell (1, 2, 5 mm) + Spacer for Short-Path Cell
Samples with low absorbance, but that are difficult to concentrate (long optical path measurement) Long-Path Cell (20, 30, 50, 100 mm) + Long-Path Rectangular Cell Holder
Normal measurement Multi-Cell Sample Compartment (sample volume: 2.5 mL min.)
For automatically
measuring samples Small sample volumes (50 μL min.) MMC-1600 8/16 Series Micro Multi-Cell Holders and Cells
Transparent in multiple cells Requires temperature control
CPS-100 Six-Cell Thermoelectrically Temperature-Controlled Cell Positioner
Samples (sample volume: 2.5 mL min.)
For temperature- Temperature-controlled with water circulation Constant-Temperature Cell Holder + NTT-2200P Constant-Temperature Water Circulator
controlled
measurements Normal measurement TCC-100 Thermoelectrically Temperature-Controlled Cell Holder
Thermoelectrically
(constant- temperature For automatically measuring samples in multiple cells CPS-100 Six-Cell Thermoelectrically Temperature-Controlled Cell Positioner
temperature controlled
measurement) Tm analysis or variable temperature measurement S-1700 Thermoelectric Single Cell Holder
Requires temperature control (constant-temperature water circulation) 160C Sipper Unit + NTT-2200P
Automatically Temperature control not necessary 160L/160T/160U Sipper Unit (Select type based on liquid volume.)
supplies sample
to flow cells Requires accurate Requires temperature control Syringe Sipper CN + NTT-2200P (Select flow cell based on liquid volume.)
(automatic analysis) control of (constant-temperature water circulation)
aspiration volume. Temperature control not necessary Syringe Sipper N (Select flow cell based on liquid volume)
For automating measurement of multiple samples Sipper Unit or Syringe Sipper + ASC-5 Auto Sample Changer
Absorption measurement Wavelength range: 240 nm min. Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603)
of suspension samples For measuring UV region above 190 nm SolidSpec-3700DUV
Suspension
Samples Light transmitted light turbidity measurement 10/50 mm Cell + Long-Path Rectangular Cell Holder
Turbidity measurement (commonly used measurement method) (Optical path length of cell depends on test method.)
Integrating sphere turbidity measurement Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603)
4
Basic Measurement
The following accessories are required for measurements using all Shimadzu spectrophotometer models.
Cells
Samples are placed in cells for measurement. The figure below A square cell with a stopper is generally used to measure volatile
shows the ten sample cell shapes. Generally, the rectangular cell liquid samples, and a microcell is used to measure a small-volume
with an optical path length of 10 mm is used. In cases when sample.
absorption is low, a cell with a longer optical path length is Sample cells are made of one of the materials listed below.
used, whereas when absorption is high, a cell with a shorter The wavelength range for each type of material has been
optical path length is used. The relationship between absorption established as follows:
strength (absorbance) and cell length is described below. By Quartz (S cells) : 190 to 2500 nm
utilizing this formula, an appropriate optical path length can be Quartz (IR cells) : 220 to 3200 nm
determined.
Absorbance (A) = ε · C · L
ε : Absorption coefficient
(a constant for given samples)
C : Concentration of sample
L : Optical path length
4 4
12.5
25
45
12 12
ø
25
12
3 2
.5
2 2
12
.5
12.5
Unit: mm
(1) (2) (3) (3)’ (4) (5) (6) (7) (7)’ (8)
Note 1: If a cap is required for 10 mm square cells, purchase a cap (P/N 200-34565-02).
Note 2: The 100 mm cell cannot be used in UV-1280 and UVmini series models. The wide 100 mm cell can be used (see UV-1280 brochure.)
Note 3: If used with a 5 nm or wider slit, a Micro Cell Holder with Mask (P/N 204-06896) is required. In UV-1280 or UVmini series models,
a Micro Cell Mask for Six-Cell Holder (P/N 206-66828) is required for measurements using a Multi-Cell Sample Compartment (P/N 206-60605-42),
and a Micro Cell Holder with Mask (P/N 206-66828) is required for measurements using a Sample Compartment Unit (P/N 206-60184-07).
Note 4: Requires a Super-Micro Cell Holder (see page 10.) In UV-1280, UVmini series or MultiSpec-1500 models, a Sample Compartment Unit is also required.
This film holder enables in-plane rotation of samples centered on the optical
axis. It can be used to attach Polarizer Type I, II, or III.
Large Polarizer Sets cannot be used.
Didymium Filter
(P/N 202-30242-09)
Holmium Filter
(P/N 202-30242-05)
This can be used for simple operation check. Didymium Filter Holmium Filter
Note 1: Expert evidence, such as wavelength accuracy, is not included. Therefore, it cannot be
used for performance verification and device management in accordance with applicable
laws, regulations and standards.
Note 2: The spectrum shown is one example. The peak wavelength and other characteristics can
vary depending on the lot.
100.0 100.0
80.0 80.0
60.0 60.0
T%
T%
40.0 40.0
20.0 20.0
0.0 0.0
300.0 400.0 600.0 800.0 900.0 300.0 400.0 500.0 600.0 700.0
nm nm
6
Four-Cell Sample Compartment Unit with Holder
(P/N 206-23670-91)
The Sample Compartment Unit is required for using other types of cells (such as a
micro cell, micro flow-thru cell, long-path rectangular cell, cylindrical cell, film holder,
or constant-temperature cell) in UV-1280, UVmini series, or MultiSpec-1500 models.
Remove the standard cell holder and replace it with the sample compartment unit.
Holds 9 to 10 mm square samples and can be placed in a regular cell holder for
measurements.
PMT, R5108
UV-2700 only (P/N 206-29869-41)
100% Baseline
60.0
%
40.0
20.0
0.0
200 600 1200 1800 2400 3000
nm
8
Long Optical Path Measurement
2.00
When the concentration of a sample is too low to be measured using a
standard 10 mm optical path length cell, a cell with a longer optical path
1.50
length is used for measurement at the optimal absorption sensitivity. As Optical Path Length: 100 mm
Abs.
1.00
permanganate becomes clearer when a 100 mm cell is used instead of a 10
mm cell.
0.50
Holds four rectangular cells: 10, 20, 30, 50, 70 and 100 mm in path If using a Four-Cell Type Long-Path Rectangular Cell Holder, use a
length. reference-side cell holder as required.
Note 1: The Four-Cell Sample Compartment (P/N
206-23670-91) is necessary.
Note 2: If the measurement requires a long
rectangular cell at the reference side, a
Reference Long-Path Rectangular Cell
Holder (P/N 204-28720) is necessary.
Note 3: 70 mm and 100 mm cells cannot be used
for UV-1280 and the UVmini series.
Holds two rectangular cells: 10, 20, 30, 50, 70 and 100 mm in path length.
Note 1: A Sample Compartment Unit (P/N 206-60184-07) is required if used in UV-1280, UVmini series, or
MultiSpec-1500 models.
Note 2: 70 mm and 100 mm cells cannot be used in UV-1280 and UVmini series models.
The wide type 100 mm cell and Long-Path Rectangular Cell Holder (for wide cells) can be used.
(See UV-1280 brochure)
Holds two cylindrical cells: 10, 20, 50 and 100 mm in path length.
Note: A Sample Compartment Unit (P/N 206-60184-07) is required if used in UV-1280, UVmini series, or
MultiSpec-1500 models.
• Applicable cells: Cells numbered (7), (7)′, and (8) in the list of cells on page 5.
• Mask: W 1.5 × H 1 mm or W 1.5 × H 3 mm selectable
• One cell each can be placed on the sample and reference sides.
Mask
Cell
Optical (P/N 206-14334)
Path Hole
Bottom Sample waste can be minimized due to the adjustable cell height design.
Adjustment Screw
of Cell
Cell height can be optimized by turning the cell height adjustment screw from
below, with the cell installed.
Holder
Required when using micro and semi-micro cells with an optical path width of 4
mm or less. (The mask width can be continuously adjusted.)
Note 1: If using a semi-micro cell with a 4 mm optical path width in UV-1600/1700/1800/1900
Series models, then samples can be measured using the standard cell holder rather
than this accessory.
Note 2: In UV-1280 and UVmini series models, this is only used for semi-micro cells with an
optical path width of 4 mm. (It is not recommended for cells with a shorter optical
path width.)
Note 3: A Sample Compartment Unit (P/N 206-60184-07) is required if used in UV-1280,
UVmini series, or MultiSpec-1500 models.
10
3 µL Capillary Cell Kit for Ultramicro Volume Measurement
(P/N 206-69746)
This kit is for use with ultra-trace samples, such as a biological sample. Suck the sample into
the capillary and set it to the capillary adapter cell for measurement. It can be set to a standard
cell holder since the size is the same as a 10 mm square cell.
• The minimum amount of sample required: 3 μL (depends on the calculation at the time of
use tube closure)
• Capillary inner diameter: 0.5 mm dia.
• Capillary (quartz) 100, with tube closure
Note: Effective optical path length is typically about 1/20 of 10 mm square cell.
This cell holder holds one micro multi-cell, either 8 or 16 cell, for micro-volume measurement.
Two micro multi-cell holders are available: a standard type (MMC-1600) and a constant
temperature water circulation type (MMC-1600C).
Note 1: A Constant-Temperature Water Circulator is required when using the MMC-1600C.
Note 2: Choose one of the following micro multi-cells.
Micro Multi-Cells
Standard Sample Volume Optical Path (L) Required Sample
Volume P/N
8 Series Micro Multi-cell 10 mm 100 µL 208-92089 • Micro-volume samples can be measured
16 Series Micro Multi-cell 10 mm 100 µL 208-92088 (Minimum sample volume: 50 or 100 μL)
8 Series Micro Multi-cell 5 mm 50 µL 208-92086 • Support for commercial microplates and micro pipettes (with 8 Series micro cell)
16 Series Micro Multi-cell 5 mm 50 µL 208-92085 • Up to 16 samples can be measured at a time (with 16 Series micro cell)
• Operating temperature range:
There are two types of micro multi-cells available in both the
10 to 60 °C (only for the constant-temperature water circulation type)
8 Series and the 16 Series models: a 50 µL type and a 100 µL
• Temperature difference between constant-temperature water and cell interior:
type. The cell intervals of the 8 Series Micro Multi-cell are
3 °C or less (only for the constant-temperature water circulation type)
applicable for use with 8 × 12 well microplates and 8-channel
• Temperature stabilization time:
pipettes. Microplate samples aspirated into multi-channel
Max. 15 min (only for the constant-temperature water circulation type)
pipettes can be injected directly into the cells for
• Connecting Joint outer diameter: 6 mm and 9 mm (two levels)
measurement.
(only for the constant-temperature water circulation type)
This mask is used to narrow the flux width when 4 mm or narrower micro
cells are placed in the Multicell Sample Compartment for measurement in
UV-1280, UVmini series, or MultiSpec-1500 models.
• Applicable cell:
10 mm Semi-micro cell (quartz) (P/N 200-66501)
10 mm Semi-micro black cell (quartz) (P/N 200-66551)
Note: This cannot be used with a CPS-100 Cell Holder Positioner.
Abs.
Controlled Cell Holder Positioner to measure the enzymatic activity of ALP. 1.0
• Substrate : 0.1 mM
• Enzyme : 0 to 0.05 U 0.0
0.0 1000.0 2000.0 3000.0 3600.0
• Temperature : 37 °C Time (Sec.)
• Detection wavelength : 420 nm
Example of Measuring Enzymatic Activity of ALP
Maintain four sample cells and a reference cell at a desired, uniform temperature by
circulating constant-temperature water.
Enables four samples to be placed simultaneously.
• Temperature range: 5 to 90 °C (depends on the performance of the
constant-temperature water circulator)
• Accepts four 10 mm square cells plus a reference cell
(Four cells can be placed on the sample side and one cell on the reference side.)
• Connection joint outer diameter: 9.5 mm
Note 1: The Four-Cell Sample Compartment (P/N 206-23670-91) is necessary.
Note 2: Requires a Constant-Temperature Water Circulator.
12
NTT-2200P Constant-Temperature Water Circulator
(P/N 208-97263)
TCC-100 Thermoelectrically
Temperature-Controlled Cell Holder
(P/N 206-29510-XX)
14
Automatic Analysis
The following accessories are used to continuously send samples to a sample compartment for measurement.
The sipper unit automatically supplies sample solutions in cells using a step motor-driven peristaltic pump. When this unit and the
auto-sample changer are used simultaneously, up to 100 samples can be measured automatically in approximately 20 minutes. The
micro flow cell can also be used for continuous measurement of the column effluent.
Sipper Units
Four types of sipper units with different cell types are available. The
stepping motor-driven peristaltic pump ensures reliable and smooth
aspiration of sample solution.
(It can be driven directly from the UV-unit so no interface is required.)
Note: The use of a Solenoid Valve (P/N 204-06599-01) and the SWA-2 Sample
Waste Unit (P/N 206-23820-91) are recommended when strong acids,
strong alkalis, or organic solvents are to be measured.
Optical Optical
Optical Path Path
Path Optical
Path
Constant-
Temperature
Inlet
Inlet Sample Water Inlet Inlet
Inlet
Cross-Section of a L-Type Flow Cell Cross-Section of a T-Type Flow Cell Cross-Section of a C-Type Flow Cell Cross-Section of a U-Type Flow Cell
Standard Type Triple-Pass Type Constant-Temperature Type Super-Micro Type
(Required Sample Volume: 2.0 mL) (Required Sample Volume: 1.5 mL) (Required Sample Volume: 25 mL) (Required Sample Volume: 0.5 mL)
• Model 160L uses the standard flow cell, which is L-shaped. • Model 160C uses a constant-temperature type flow cell. Due to the
• Model 160T uses a triple-pass flow cell. Due to the long narrow double-walled structure of the flow cell, constant-temperature
roughly-straight shape of the flow cell, samples flow smoothly into water can be circulated around the flow cell to ensure more
and out of the cell, which minimizes contamination and the accurate and efficient constant-temperature measurements.
formation of bubbles, even with samples prone to bubbles. • Model 160U is for micro volumes. It enables measurement of smaller
quantities, with lower carryover levels, than other flow cells.
If the ASC-5 is combined with a sipper unit or syringe sipper, it is possible to configure an
automated multisample spectrophotometry system for liquid samples.
• It is equipped with an accurate X–Y–Z 3-axis movement mechanism.
• Up to eight sets of parameters, such as rack size and number of test tubes, can be
memorized in the battery back-up protected files.
• Up to 100 test tubes can be placed on the rack.
Note 1: Supports using commercially available test tube stands with a footprint smaller than 220 × 220 mm.
Note 2: A USB adaptor ASC (P/N 206-25235-91) is required when used in UV-1280, UV-1800/1900, or
UV-2600/2700 models.
Note 3: Cannot be used in the SolidSpec-3700/3700DUV.
Note 4: The following power supply is required: 100 to 120 or 200 to 240 V AC, 50/60 Hz, 66 VA
Note 5: ASC-5 is not sold in Europe since it is not a RoHS compliant product.
The SWA-2 is a convenient unit for sample suction and disposal that can be used in place of an
aspirator.
• Built-in suction pump
• Size: W 280 × D 300 × H 450 mm (up to upper edge of gauge)
• Power requirements: 100 V AC, 50/60 Hz, 20 VA
Note: Use this unit instead of aspirators at sites where water pressure can vary, due to potential variability in
sample suction volumes.
This accessory is required for strong acid, strong alkaline, and ester solutions, due to the lack of chemical resistance in peristaltic pumps used in
sipper units. It also requires an SWA-2 Sample Waste Unit (P/N 206-23820-58).
16
Micro Flow-Through Cell with Holder
Used for the continuous analysis of samples such as the liquids produced by column
chromatography.
• Tubing I.D.: 1 or 2 mm
Note: Sample Compartment Unit (P/N 206-60184-07) is necessary for the UV-1280, UVmini
series, and MultiSpec-1500.
Optical
Description P/N Cell Volume
Path Length
10 mm Micro Flow-Through Cell with Holder 204-06222 10 mm 0.3 mL
5 mm Micro Flow-Through Cell with Holder 204-06222-41 5 mm 0.15 mL
Allows the tubes of a flow-through cell, for example, to be connected through the
front panel of the instrument.
Note: Sample Compartment Unit (P/N 206-60184-07) is necessary for the UV-1280, UVmini
series, and MultiSpec-1500.
This flow cell allows UV-VIS detection for high performance liquid chromatography
at variable wavelengths.
Enables connection to a Gilson GX-271 liquid handler. The liquid handler performs a
variety of pretreatments automatically, including sample dispensing and dilution, and
the addition of reagents. This connection kit interfaces the spectrophotometer and
the liquid handler.
• The connection kit consists of a flow cell unit and connection cable. The liquid
handler is not included.
Note 1: A Sample Compartment Unit (P/N 206-60184-07) is required for use in UV-1280
Flow Cell Unit
and UVmini series models.
Note 2: Cannot be used in the SolidSpec-3700/3700DUV.
UV-2600/2700, UV-3600/3600 Plus only (P/N 206-54175-41) Description P/N Process Monitor
System
spectrophotometer using a high-precision optical fiber coupler. This UV-2700 206-27700-41 Choose among these
optical fiber coupler has been designed for the UV-2600/2700 and UV-3600/3600 Plus 206-23000-91
UV-3600/3600 Plus to guarantee high throughput and stability. Crossflow Cell Note 2 206-53570-13 ✓
Note 1: If fibers are connected, the spectrophotometer basic specifications for Optical Fiber Coupler
206-54175-91 ✓
measuring accuracy, stray light, etc. are out of guarantee. (with two 0.5 mm optical fibers)
Note 2: Crossflow cell is designed to have maximum throughput at room Optical Fiber, 2 m (set of 2) Note 3
206-53875-92
temperature. Optical Fiber, 5 m (set of 2) Note 3 206-53875-93
Crossflow cells are intended for liquids. They are not used for gases. Optional
10m optical fibers (2 pcs. a set) Note 3 206-53875-94
Note 3: Intensity available for transmission decreases according to the fiber length
by approximately the following ratios. 20m optical fibers (2 pcs. a set) Note 3 206-53875-95
18
Suspension and Opaque Sample Measurement
Measurement of suspension samples is difficult due to the scattering of reflected light by fine particles in the solution. Integrating
spheres are used in this type of analysis. The glass method involves the placement of a scattering board behind the sample, resulting
in the equalization of scattering coefficients of the reference side and sample side. As shown in Figure 1, the integrating sphere
method involves a barium sulfate-coated sphere that draws the scattered light, allowing all of the light to reach the detector. Since
light cannot penetrate opaque samples, it is reflected on the surface of the samples. Figure 2 shows one case in which incoming light
is reflected symmetrically with respect to the normal line (forward reaction), and another case in which the incoming light is
scattered in different directions. The former is referred to as specular reflection and the latter is referred to as diffuse reflection.
Reference Beam
Ip+id I0
Side-on Type
Photomultiplier
Standard Sample
Sample White Board Integrating
Beam Sphere
M1
Figure 3. Opaque Sample Measurement Using the
Integrating Sphere Method
100.00
100.00
4.000
4.000
80.00
80.00
3.000
3.000
60.00
60.00
0.100 (Abs/div.)
2.000
40.00
40.00
1.000
1.000
20.00
0.000
0.000
0.00
0.00
400 500 600 700 750 400 500 600 700 750
(nm)
Spectrum of a Chlorophyll Suspension Solution Reflectance Spectrum of Paint
20
ISR-2600 Integrating Sphere Attachment UV-2600/2700 only (P/N 206-28400-58)
ISR-2600Plus Integrating Sphere Attachment UV-2600 only (P/N 206-28410-58)
In combination with a 0° or 8° incident angle integrating sphere and S/R exchange functionality
of the spectrophotometer, either diffuse or specular reflectance can be measured without
using any special attachments. The ability to change the size of the flux in the reflectance
measurement unit enables measuring reflectance at micro areas of samples (minimum flux size
of about 2 × 3 mm). The flux size can also be narrowed to about 3 × 3 mm in the
transmittance measurement unit.
The ISR-2600Plus Integrating Sphere Attachment includes two detectors: a photomultiplier
tube and InGaAs detector.
ISR-2600/2600Plus Common Specifications
• Integrating sphere I.D.: 60 mm
• Maximum size of reflectance sample: W 70 × H 70 × D 20 mm (0° incident angle)
W 70 × H 70 × D 12 mm (8° incident angle)
M3 Mask
ISR-2600 Specifications
Reference Beam
• Wavelength range: 220 to 850 nm
• Noise level: 0.1%T RMS 500 nm (UV-2600), 0.3%T RMS 500 nm (UV-2700)
•100% flatness: ± 0.5%T (UV-2600), ± 1.5%T (UV-2700) M2
ISR-2600Plus Specifications 8°
90°
• Wavelength range: 220 to 1400 nm
• Noise level: 0.1%T RMS 500 nm, 0.3%T RMS 900 nm Mask
Detector
(Mounted Sample Beam
at the Bottom)
Optical Diagram
22
150 mm Dia. Integrating Sphere Attachments
LISR-2100 UV-3600 only (P/N 206-23862-91)
LISR-3100 UV-3600 only (P/N 206-23862-92)
This attachment is used to measure the reflectance spectrum of solid
samples, such as powder, paper or cloth.
It is also used to measure the transmittance of solid or liquid samples.Note 1 Reference
Beam
It is suitable for color analysis because stable measurement can be
performed regardless of the surface configuration of the samples.
Sample
Beam
• Measurement wavelength range: 240 to 840 nm (LISR-2100),
240 to 2400 nm (LISR-3100)
PMT
• Integrating sphere I.D.: 150 mm
PbS
• Reflectance sample installation space: Approx. W 150 × H 170 × D 30 mm
(LISR-3100 only)
Note 1: Transmittance measurement accessory (P/N 206-17270) is required.
Note 2: LISR-2100 and LISR-3100 are not sold in Europe since they are not RoHS
compliant products.
This unit uses a lens and mask to mask the beam that passes through the
integrating sphere opening. The minimum beam diameter is about 1 mm.
It requires a sample base plate integrating sphere unit at the same time.
Integrating
Sphere Lens Unit (shaded area)
for MPC)
ø8 (Uses mask
Approx. 32
2
25
Base
Overview Diagram
Note: For UV-2600, MPC-2600A and BIS-3100 sample base plate integrating sphere set are separately required.
For UV-3600Plus, MPC-603A and BIS-603 sample base plate integrating sphere set are separately required.
For SolidSpec-3700/3700DUV, BIS-3700/3700DUV is separately required.
24
Absolute Specular Reflectance Attachments
To Detector Incident Light
These attachments are used to measure the absolute reflectance of specular
reflected light, as indicated in Figure 2 (page 19). Reference samples are not used for To Detector Incident Light
• V-N method enables switching between light paths for sample measurements and Ref
• Sample size: Approx. 25 mm dia. or 20 mm square up to 200 mm dia. or 150 mm Measurement Light
Note: These polarizers are only used in Multipurpose Large Sample Compartments or Absolute
Specular Reflectance Attachments.
Effective Wavelength
Description P/N
Diameter Range
Large Polarizer Set 206-15694-40 20 mm 250 to 2300 nm
Polarizer Type I 206-13236-41 18 mm 400 to 800 nm
Polarizer Type II 206-13236-42 17 mm 260 to 700 nm
Polarizer Type III 206-13163-40 10 mm 260 to 2300 nm
Sample
Reference beam
Mask
60° s
45° s
Integrating Sphere Sample beam
for Reference
20° s
5°
Angles for the Sample holder
and the Detector can be set
20° p
independently. Integrating Sphere
for Sample
45° p
60° p
Movable portion
26
Special Accessories for SolidSpec-3700
The Automatic X–Y Stage enables automatic measurements for the points specified in advance
and is a powerful accessory for high-throughput measurements.
Purge Box
SolidSpec-3700 DUV only (P/N 206-21788-58)
The Purge Box is used with the DDU-DUV Direct Detection Unit, allowing the inside to be
purged. The Purge Box has a film holder and a six-cell holder and allows the cell positions to be
moved without opening the cover of the SolidSpec-3700DUV.
• Maximum sample size: 60 × 60 mm, 20 mm thickness
The Large Specular Reflectance Attachment is needed for relative specular reflectance
measurements. This accessory is mounted in the main body of SolidSpec-3700/3700DUV and
enables reflectance measurements while keeping the samples horizontal. The Direct Detection
Unit DDU or DDU-DUV is not required for this accessory.
10 mm square cell holder for integrating sphere built into SolidSpec-3700/3700DUV systems.
This interface is used when using an analog data recorder to Used to connect the spectrophotometer to the PC.
record the measurement signal from a spectrophotometer. It
provides analog signal output, such as for monitoring liquid
chromatography, and can be connected to an integrator.
• Analog output full scale: 100 mV/2 Abs. or 100 mV/100%T
28
Optional Software
Easy and accurate water analysis can be conducted in combination with simplified
reagents.
• All measurement parameter settings are included internally for 22 sample types / 39 items
for the UV-1280. All items, including measurement wavelengths, calibration curve,
measurement time, and measurement concentration range, are set automatically by
simply selecting the item.
• Results can be acquired even without analytical knowledge through operation in
accordance with screen instructions. The pack comes with an analysis guide that displays
the model number of the reagent to be used and the operation procedure, so there is no
need to refer to the manual.
• If the optional multicell holder (6 cells) is used, up to six cells can be measured
consecutively in one analysis.
• Automatic analysis commences after a specified time. The elapsed time is displayed on
screen, concentration values are displayed automatically after the specified time has Operation Screen
elapsed, and a buzzer sounds to state that analysis is complete.
Tm Analysis Software
(P/N 206-57476-91)
This software is used with the S-1700 cell holder. It enables temperature versus
absorbance graph data to be uploaded to a computer for analyzing the Tm (melting
temperature) of nucleic acids (DNA and RNA) or other substances.
• OS: Windows 10 Pro 64 bit edition, Windows 7 Professional 32/64 bit edition
Note 1: A separate RS-232C cable (P/N 208-94860) is required for connecting a computer to the S-1700 cell
holder.
Note 2: If used for the UV-1800/1900 spectrophotometer, a separate USB cable (P/N 088-50602-49) is
required for connecting the computer to the main unit.
30
Film Thickness Measurement Software
(P/N 206-66877)
This software measures the thickness of thin films from the wavelengths of peak
(or valley) interference waveforms overlapping the spectrum.
The film thickness is measured through optical methods without physical contact.
• The film thickness is calculated from linear regression by applying the method of least
squares to the wavelengths of the multiple peaks and valleys automatically detected. (The
thin film's refractive index and the angle of incidence must be configured as calculation
conditions.)
• The calculation conditions can be changed with respect to the measured spectra, enabling
recalculation.
• A range can be set for use in the calculations while checking the spectral interference
waveform onscreen.
Recalculation Window
• The measurable film thickness range is (minimum measured wavelength)/(film's refractive
index) to 50 × (maximum measured wavelength)/(film's refractive index). (Reference value) Note: If used for a UV-1601 spectrophotometer, an RS-232C interface
• OS: Windows 10 Pro 64 bit edition, Windows 7 Professional 32/64 bit edition cable (P/N 208-94860) is required.
This software is used to calculate the solar transmittance, solar • User-settable weighting factor charts can be saved as a file.
reflectance, visible light transmittance, and visible light reflectance. It • Results can be recalculated based on different standard samples.
• Users can create user-defined Illuminant for color value calculations.
also can calculate some color-related values (tristimulus values,
User-specified illumination settings can be saved as a file.
chromaticity coordinates, primary wavelength, and excitation purity). • Highly accurate calculations can be performed using white tile correction.
Reflectance data from the white tile can be saved as a file.
• Chromaticity coordinates can be graphed.
• OS: Windows 10 Pro 64 bit edition, Windows 7 Professional 32/64 bit edition
Simple Design
From the start, the software's user-friendliness allows users to perform operations with ease.
With extensive features, LabSolutions UV-Vis meets a wide range of users' expectations.
Report
Easily create report layouts.
Print from the measurement window with one click. Report is printed.
32
Spectra Evaluation Function
In addition to providing measurement and analysis results, judgment results are also provided.
With this feature, LabSolutions UV-Vis enables users to maintain a product's quality.
To Analysis Software
Automatically generates a text
file when the spectra data are
saved. It can be immediately
imported into other software.
To Excel
Real-time transfer of the spectrum waveform to Excel during
Matrix Output measurement.
Outputs multiple spectra to one text file. No need to create a CSV file each time.
Easy to import data into multivariate analysis software.
Line up wavelengths
horizontally.
LabSolutions DB UV-Vis
(P/N 207-24526-92)
* Coming Soon
Available Available
LabSolutions database Unavailable
(The database resides on a local PC) (The database resides on a server)
34
Database Management Prevents Mistakes
With LabSolutions DB UV-Vis System and LabSolutions CS UV-Vis System,
the analysis data are managed securely by the database. Overwriting, Analysis Postrun analysis Postrun analysis
deletion and other mistakes typical of data file management do not Revision number: 1 Revision number: 2 Revision number: 3
occur.
In addition, when postrun analysis is performed using the acquired data,
postrun analysis data revision numbers are automatically assigned,
Reduced operator errors
preventing the accidental overwriting of raw data.
Solid Security
An audit trail to ensure the reliability of data and document e-mail requirements. It is also possible to set lockout functions to prevent
transmission functions when any event occurs in the system can be set illegal access, and set a registered user’s deletion and change. In
up. User accounts are managed using passwords, where password addition, a box can be selected to prevent overwriting a data file, and
length, complexity and term of validity must satisfy specified outputting an item to a report can also be performed.
Project
A ccess O K A
data Project
B
data A cce s s OK
Report Set**
Operation history Results
Data File
www.shimadzu.com/an/ The contents of this publication are provided to you “as is” without warranty of any kind, and are subject to change without notice. Shimadzu
does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication.