FTNG 02 1, 700 1, 700 400 20 MM 1, 500 mm. 12 12 CANTILEVER 12 MM 24 2, 500 mm. PURPOSES UNLESS OTHERWISE INDICATED.
8700 3. FOR ALL REQUIREMENTS, REFER TO ARCHITECTURAL,
4000 1400 3100 200 FTNG 03 1, 700 1, 700 400 20 MM 1, 500 mm. 12 12 CANTILEVER 12 MM 24 2, 500 mm. SANITARY, ELECTRICAL AND MECHANICAL.
1400 2600 1400 1700 1, 000 1, 200 350 16 MM 850 mm./ 8 CANTILEVER 12 MM 8 1, 500 mm.
A FTNG 04 1, 000 mm. 9
1000
L/5 VARIES L/5
FTNG 05 800 800 250 12 MM 650 mm. 4 4 CANTILEVER 12 MM 8 1, 200 mm.
FOOTINGS L2/5 L2/5 L3/5 L3/5
SPACED
2-1.2 mm. x 2"x6" C-PURLINS FASCIA LESS THAN 00025 B.T..
GROUND AND 2" CLEAR CONCRETE DEPOSIRED AGAINST
1200
BAR B
EQUALLY
SPACED
TOP OF GRADE BEAM
THE FRAMEWORK. 5. UNLESS OTHERWISE NOTED, ALL BEDDED SLAB SHALL BE
1.5 mm. x 2" x 3" TUBULAR STEEL PLATE
REINFORCED WITH no. 3 REBARS AT 10" O.C. EACHWAY
1 C4 C4
AT CENTER OF SLAB CONSTRUCTION JOINTS FOR THE
1.5 mm. x 2" x 6" TUBULAR RAFTER BEAM NO.
DIMENSIONS ( METERS)
LENGTH AT SUPPORT
REBARS
AT MIDSPAN AT SUPPORT
STIRRUPS SPACING CONCRETE MIXES AND PLACINGS JOINTS FOR SAME SHALL NOT BE MORE THAN TEN (10)
1. UNLESS OTHERWISE SPECIFIED, THE MINIMUM 28 DAYS FEET APART.
VERIFY DEPTH
TOP BARS 3 - 16 mm. Ø 3 - 16 mm. Ø 3 - 16 mm. Ø 4 @ 50 mm., 3 @ 100 mm.,
CYLINDER COMPRESSIVE STRENGTH OF CONCRETE
WIDTH
TORSION BARS 2 - 12 mm. Ø 2 - 12 mm. Ø 2 - 12 mm. Ø REST @ 175 mm. ON 6. PROVIDE EXTRA REINFORCEMENT AT CORNER SLABS
AS FOLLOWS:
3900
CENTER
VERIFY
WIDTH DEPTH (Two adjacent discontinuous edge) AS SHOWN BELOW.
GB 01 LENGTH
STIRRUPS LENGHT FOOTING AND BEAMS ON GRADE 3000 PSI
250 350 LENGHT 1, 000 mm. FTNG. TOP LINE
DIAMETER 10 mm. Ø
COLUMNS 3000 PSI 5 no. 3 BARS AT 8" O.C..
THICKNESS
SEE FTNG.
BOTTOM BARS 3 - 16 mm. Ø 3 - 16 mm. Ø 3 - 16 mm. Ø STIRRUP SIZE : 7" x 11" SLABS, TOPPING, BEAMS AND GIRDERS 3000 PSI BEAM BOTTOM BARS
TOP BARS 3 - 16 mm. Ø 3 - 16 mm. Ø 3 - 16 mm. Ø 4 @ 50 mm., 3 @ 100 mm.,
PARTITIONS, PARAPET WALLS 3000 PSI
C4 TORSION BARS 2 - 12 mm. Ø 2 - 12 mm. Ø 2 - 12 mm. Ø REST @ 175 mm. ON
STIFFENER
BM 01 mm.
STIRRUPS LENGHT 3. STRIPPING OF FORMS AND SHORES SHALL
3
BAR B TOP OF GRADE BEAM
C4 C4 250 400 LENGHT 1, 100 mm.
STIFFENER DIAMETER 10 mm. Ø
EQUALLY
SPACED BE AS FOLLOWS:
1 DAY
1300
10mm DIAM.
BOTTOM BARS 5 - 16 mm. Ø 7 - 16 mm. Ø 5 - 16 mm. Ø STIRRUP SIZE : 7" x 13"
HORIZONTAL BARS FOUNDATIONS
TOP BARS 5 - 16 mm. Ø 3 - 16 mm. Ø 5 - 16 mm. Ø 4 @ 50 mm., 6 @ 80 mm., SPACED @ 250mm
COLUMNS AND WALLS 3 DAYS 7. PROVIDE SUPPLEMENTARY REINFORCEMENT AT SMALL
1.5 mm. x 2" x 6" TUBULAR RAFTER
2-1.2 mm. x 2"x6" TORSION BARS 2 - 12 mm. Ø 2 - 12 mm. Ø 2 - 12 mm. Ø 4 @ 100 mm., REST @
C-PURLINS FASCIA 180 mm. ON CENTER
UNFRAMED OPENINGS IN FLOOR SLABS AS SHOWN;
WIDTH DEPTH BEAMS AND GIRDERS 21 DAYS
VERIFY DEPTH
BM 02 VERIFY
STIRRUPS LENGHT MIN. 1 no. 5
1400
WIDTH
AIR WELL 250 400 LENGHT 1, 100 mm. VERTICAL BARS SLABS TRIMMERS MAY
4700
THICKNESS
SEE FTNG.
180 mm. ON CENTER BEAMS
2000
WIDTH DEPTH
BM 03 VERIFY
STIRRUPS LENGHT BUCKETS, WHEEL BORROWS. NO CHUTE WILL BE 2 no. 5 EACH
LENGTH
250 400 LENGHT 1, 100 mm.
FTNG. BOTTOM LINE
ALLOWED EXCEPT FOR THE PURPOSE OF TRANSFERRING CORNER
DIAMETER 10 mm. Ø
CONCRETE FROM HOPPERS TO BUGGIES, BUCKETS, PROVIDE EXTRA
4
STIFFENER
C4 BOTTOM BARS 2 - 16 mm. Ø 3 - 16 mm. Ø 2 - 16 mm. Ø STIRRUP SIZE : 7" x 13"
TOP BARS 7 - 16 mm. Ø 7 - 16 mm. Ø 4 @ 50 mm., 3 @ 100 mm.,
PLAN SECTION WHEEL BORROWS, IN WHICH CASE THEY SHALL NOT BARS (NOT SHOWN) HOOK SLAB
EXCEED 20 FEET IN AGGREGATE LENGTH. NO DEPOSITING PARALLEL TO SIDES REINF. OVER
1400
LENGTH
1.5 mm. x 2" x 3" TUBULAR STEEL PLATE 250 400 LENGHT 1, 100 mm. SLAB REINF. LESS
DESIGNERS AND ONLY FOR CONDITIONS WHERE VIBRATORS
1000
DIAMETER 10 mm. Ø
S 2 SCALE 1 : 40 m. AREA OF TRIMMER 2-6" EXTENDED
2-1.2 mm. x 2"x6" C-PURLINS FASCIA
BOTTOM BARS 5 - 16 mm. Ø 5 - 16 mm. Ø STIRRUP SIZE : 7" x 13" ARE EXTREMELY DIFFICULT TO ACCOMPLISH. BARS TRIMMER BAR
TOP BARS 5 - 16 mm. Ø 5 - 16 mm. Ø 4 @ 50 mm., 3 @ 100 mm.,
2-6" BEYOND
600
1400
1.2 mm. x 2" x 3" DN
DIAMETER 10 mm. Ø TOGETHER. NOTES
1000
C-PURLINS @ REINFORCEMENT
700 mm. O.C. BOTTOM BARS 2 - 16 mm. Ø 4 - 16 mm. Ø 2 - 16 mm. Ø STIRRUP SIZE : 6" x 11" BLOCK
TOP BARS 4 - 16 mm. Ø 4 - 16 mm. Ø 4 @ 50 mm., 3 @ 100 mm.,
4. IF BEAM REINFORCING BARS END IN A WALL, THE CLEAR
THK. A. MIN. SPLICE LAP 10"
1.5 mm. x 2" x 6" TORSION BARS 2 - 12 mm. Ø 2 - 12 mm. Ø REST @ 175 mm. ON DISTANCE FROM THE BAR, TO THE FARTHEST FACE OF HORIZONTAL VERTICAL
17 16 15 14 13 12 11 10 9 8 B. PROVIDE RIGHT ANGLE REINFORCEMENT
2800
TUBULAR RAFTER WIDTH DEPTH CENTER
VERIFY 7 THE WALL SHALL NOT BE LESS THAN 2" MINIMUM. AT CORNERS 3" LONG
1.5 mm. x 2" x 3" CRB LENGTH
STIRRUPS LENGHT
C. WHERE CHB AJOINED COLUMNS,
BEAM TUBULAR STEEL PLATE 200 350 LENGHT 900 mm. 1 2 3 4 5 6 EMBEDMENT SHALL BE 40 DIA. FOR TENSION AND 4" 3 @ 24 " O.C. 3 @ 24 " O.C.
R.C. BEAMS, WALL DOWELS WITH
STIFFENER
DIAMETER 10 mm. Ø 20 DIA FOR COMPRESSION BARS. THE SAME SIZE, VERTICAL OR
BOTTOM BARS 2 - 16 mm. Ø 2 - 16 mm. Ø STIRRUP SIZE : 5" x 11"
6" 3 @ 24 " O.C. 3 @ 24 " O.C. HORIZONTAL REINFORCEMENT
1400
TOP BARS 4 - 16 mm. Ø 2 - 16 mm. Ø 4 - 16 mm. Ø 4 @ 50 mm., 3 @ 100 mm., 5. MINIMUM CONCRETE PROTECTION OF REINFORCING SHALL BE PROVIDED.
12 mm. REBAR WELDED
TORSION BARS 2 - 12 mm. Ø 2 - 12 mm. Ø 2 - 12 mm. Ø
TO RAFTER
REST @ 175 mm. ON
CENTER
BARS SHALL BE AS SHOWN:
4,850 WIDTH DEPTH
IB mm.
STIRRUPS LENGHT
.500 mm. THICK RIBTYPE LENGHT 850 mm.
200 300
ROOFING SHEET
1765
STIFFENER DETAILS) THAN 3/4" FOR EVERY 10' OF FREE SPAN. HORIZONTAL VERTICAL
TORSION BARS 1 - 16 mm. Ø 1 - 16 mm. Ø 1 - 16 mm. Ø REST @ 175 mm. ON 10 mm. DIAM. BEND BARS
WIDTH DEPTH CENTER SP. @ 200 mm. O.C.
176
1.5 mm. x 2" x 3" VERIFY NOTE: SLAB
TUBULAR STEEL PLATE EB LENGTH 400
STIRRUPS LENGHT
THICKNESS =
HORIZONTAL
150
350
LENGHT 450/400 mm.
125 mm THICK CONCRETE SLABS & VERTICAL BARS
3000
2-1.2 mm. x 2"x6" DIAMETER 10 mm. Ø 3 -10 mm. DIAM. REBARS 4" 3 at 10" O.C. 3 at 12" O.C.
STAGGERED
C-PURLINS FASCIA BOTTOM BARS 1 - 16 mm. Ø 1 - 16 mm. Ø 1 - 16 mm. Ø STIRRUP SIZE : 2.5" x 13/11"
TOP BARS 2 - 12 mm. Ø 2 - 12 mm. Ø 2 - 12 mm. Ø 4 @ 50 mm., 3 @ 100 mm., 10 mm. DIAMETER REBARS
LANDING 1. ALL REINFORCEMENT SHALL BE 3/4" CLEAR MINIMUM FROM OUTSIDE
.500 mm. THICK RIBTYPE TORSION BARS REST @ 175 mm. ON SP. @ 200 mm. ON CENTER TOP AND BOTTOM OF SLAB.
ROOFING SHEET BOTH FACES
VERIFY
WIDTH DEPTH CENTER
12 mm. DIAM.
2. FOR TWO-WAY SLAB, BARS ALONG THE SHORTER SPAN SHALL
1.5 mm. x 2" x 6" STIFFENER HORIZONTAL
LENGTH
STIRRUPS LENGHT
BOTTOM BARS SP. @ BE PLACED BELOW THOSE ALONG THE LONGER SPAN AT 6" 4 at 10" O.C. 4 at 12" O.C.
1235
TUBULAR RAFTER LENGHT 500 mm. SHALL BE
200 150
1.5 mm. x 2" x 3" DIAMETER 10 mm. Ø
200 mm. O.C. CENTER AND OVER THE LONGER SPAN BARS NEAR THE
TUBULAR STEEL PLATE
INSIDE
BOTTOM BARS 2 - 12 mm. Ø 2 - 12 mm. Ø 2 - 12 mm. Ø STIRRUP SIZE : 3" x 5" 12 mm. DIAM. BOTTOM SUPPORT UNLESS OTHERWISE INDICATED OR SHOWN IN
CUT BARS SP. @ 200 BOTH FACES
2-1.2 mm. x 2"x6"
BEAM
C-PURLINS FASCIA mm. O.C. FINISH FLOOR LINE OR SHOWN IN DETAILS, THE SPACING OF THE BARS AT THE HORIZONTAL
8" 4 at 12" O.C. 4 at 12" O.C.
12 mm. REBAR WELDED
(SEE BEAM (SEE BEAM
COLUMN STRIPS CAN BE APPROXIMATELY 1-1/3 OF THE SHALL BE
TO RAFTER 1.2 mm. x 2" x 3"
MIDDLE STRIP, BUT IN NO CASE GREATER THAN 2-1/3 TIMES OUTSIDE
STIFFENER
C-PURLINS @
700 mm. O.C. SECTION SCHEDULE FOR
DETAILS)
SCHEDULE FOR
DETAILS)
THE SLAB THICKNESS.
TABULATED BEAM
2 RAFTER DIAGRAM 3 SCHEDULE & DETAILS 5 STAIR DETAILS 6 STRUCTURAL NOTES
SCALE
S 2 1 : 50 m.
S 2 SCALE NTS S 2 SCALE 1 : 40 m. S 2 SCALE NTS
DESIGNER DESIGNER DRAWN BY CHECKED BY ARCHITECT STRUCTURAL ENGINEER REVISION DATE DESCRIPTION PROJECT TITLE SHEET CONTENTS OWNER SHEET NO.
FLAM ARCH. AST PRC NO. 00 22 333
AS TOLEAN + ARCHITECTS DATE : AUGUST 25, 2021 DATE : VALIDITY JULY 12, 2023
O OSE T O STO E S O SES O EL . OLO A S
PTR NO. 6868307
ARCHITECTURE BUILDERS PLANNING THESE DRAWINGS AND ITS SPECIFICATION INTENTS ARE INSTRUMENTS OF
PROFESSIONAL SERVICE PURSUANT TO RA 9266 (ARCHITECTURE ACT OF 2004). SECTION 33 - ISSUED ON JANUARY 11, 2021
ES EN E T ASE ENT
AS SHOWN A EL L. OLO A 2 2
JA 146 UPPER COGCOGA, KM. 3 PICO, LA TRINIDAD, BENGUET OWNERSHIP OF PLANS, SPECIFICATIONS & OTHER CONTRACT DOCUMENTS, RA 8293 (COPYRIGHT
TRAININGS LAW) AND P.D. 49 THEY ARE THE INTELLECTUAL PROPERTY AND DOCUMENTS OF AS ISSUED AT LA TRINIDAD, BENGUET PRC NO.
E-MAIL ADD.: [email protected] BOSH (SO1)
TOLEAN + ARCHITECTS, WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS ALVEZ S. TOLEAN, uap LOCATION ADDRESS PROJECT NO.
EXECUTED OR NOT, IT SHALL NOT BE USE OR REPRODUCE IN WHOLE OR IN PART UAP NO. 17662 PTR NO.
MOBILE NO.S COSH (SO2) FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS OR BUILDINGS,
LCM (SO3) WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT PROPER PERMISSION OR IAPOA NO. 17662 295419 090720 ISSUED ON
SMART # 0921 627 2449 / B.B.S. WRITTEN CONSENT FROM THE ARCHITECT. LUBAS, LA TRINIDAD, BENGUET BALILI, LA TRINIDAD, BENGUET
GLOBE # 0927 4451 451 FIRST AIDER JUNE 30, 2021 ISSUED AT