2 channels
Low cost
200 MHz bandwidth
Up to 1 GS/s sampling rate
Arbitrary waveform generator
Advanced digital triggers
Persistence display modes
USB connected and powered
Mask limit testing
Serial bus decoding
www.picotech.com
Powerful, portable, and versatile
The PicoScope 2200A Series oscilloscopes offer a small, light,
modern alternative to bulky benchtop devices. You can now fit a
200 MHz, 1 GS/s instrument easily in your laptop bag! They are
perfect for engineers on the move, and ideal for a wide range of
applications including design, test, education, service, monitoring,
fault finding, and repair.
A small form factor is not the only benefit of these PC-based scopes.
With our PicoScope 6 software, high-end features such as serial
decoding and mask limit testing are included as standard. New
functionality is regularly delivered through free upgrades, optimized
with the help of feedback from our customers.
Advanced triggers
As well as the standard range of triggers found on most oscilloscopes, the PicoScope 2200A Series offers one of the best selections
of advanced triggers available. These include pulse width, windowed and dropout triggers to help you find and capture your signal quickly.
Spectrum analyzer
With the click of a button, you can open a new window to display a spectrum plot of selected channels up to the full bandwidth of the
oscilloscope. A comprehensive range of settings gives you control over the number of spectrum bands, window types and display modes.
PicoScope software allows you to display multiple spectrum views with different channel selections and zoom factors, and see these
alongside time‑domain waveforms of the same data. A comprehensive set of automatic frequency-domain measurements can be added to
the display, including THD, THD+N, SINAD, SNR and IMD. You can even use the AWG and spectrum mode together to perform swept
scalar network analysis.
Automatic measurements
PicoScope allows you to automatically display a table of calculated measurements for troubleshooting and analysis. Using the built-in
measurement statistics you can see the average, standard deviation, maximum and minimum of each measurement as well as the live value.
You can add as many measurements as you need on each view. Each measurement includes statistical parameters showing its variability.
For information on the measurements available in scope and spectrum modes, see Automatic Measurements in the Specifications table.
Math channels
With PicoScope 6 you can perform a variety of mathematical calculations on your input
signals and reference waveforms.
Use the built-in list for simple functions such as addition and inversion, or open the
equation editor and create complex functions involving trigonometry, exponentials,
logarithms, statistics, integrals and derivatives.
To protect your investment, both the PC software and firmware inside the scope can be updated. Pico Technology have a long history of
providing new features for free through software downloads. We deliver on our promises of future enhancements year after year, unlike
many other companies in the field. Users of our products reward us by becoming lifelong customers and frequently recommending us to
their colleagues.
Movable axes: The vertical axes Trigger toolbar: Automatic measurements: Display Zoom overview: Spectrum view:
can be dragged up and down. Quick access to calculated measurements for trouble- Click and drag for View FFT data
This feature is particularly useful main controls, with shooting and analysis. You can add as many quick navigation in alongside scope
when one waveform is obscuring advanced triggers in measurements as you need on each view. zoomed views. view or in dedicated
another. There’s also an Auto a pop-up window. Each measurement includes statistical spectrum mode.
Arrange Axes command. parameters showing its variability.
Detailed specifications
VERTICAL
Input channels 2
Bandwidth (–3 dB) 10 MHz 25 MHz 50 MHz 100 MHz 200 MHz
Rise time (calculated) 35 ns 14 ns 7 ns 3.5 ns 1.75 ns
Vertical resolution 8 bits
Enhanced vertical resolution Up to 12 bits
Input ranges ±50 mV, ±100 mV, ±200 mV, ±500 mV, ±1 V, ±2 V, ±5 V, ±10 V, ±20 V
Input sensitivity 10 mV/div to 4 V/div (10 vertical divisions)
Input coupling AC / DC
Input characteristics BNC, 1 MΩ ∥ 14 pF BNC, 1 MΩ ∥ 13 pF
±250 mV (50 mV to 200 mV ranges)
Analog offset range - ±2.5 V (500 mV to 2 V ranges)
(vertical position adjustment) ±20 V (5 V to 20 V ranges)
DC accuracy ±3% of full scale
Overvoltage protection ±100 V (DC + AC peak)
HORIZONTAL (TIMEBASE)
Maximum sampling rate 1 ch. 100 MS/s 200 MS/s (ChA) 500 MS/s 1 GS/s 1 GS/s
(real-time) 2 ch. 50 MS/s 100 MS/s 250 MS/s 500 MS/s 500 MS/s
Equivalent sampling rate (ETS) 2 GS/s 4 GS/s 5 GS/s 10 GS/s 10 GS/s
Maximum sampling rate (streaming) 1 MS/s 9.6 MS/s
Timebase ranges 10 ns to 5000 s/div 5 ns to 5000 s/div 2 ns to 5000 s/div 1 ns to 5000 s/div 500 ps to 5000 s/div
Buffer memory 8 kS 16 kS 32 kS 40 kS 48 kS
(shared between active channels)
2 MS per channel in PicoScope software. 100 MS (shared) in PicoScope software.
Buffer memory (streaming mode)
Up to available PC memory when using SDK.
Maximum buffers (normal triggering) 10 000
Max. buffers (rapid block triggering) Not available 32
Timebase accuracy ±100 ppm ±50 ppm
Sample jitter < 30 ps RMS < 5 ps RMS
TRIGGERING
Sources Ch A, Ch B
Trigger modes None, auto, repeat, single None, auto, repeat, single, rapid (segmented memory)
Advanced triggers Edge, window, pulse width, window pulse width, dropout, window dropout, interval, logic.
Trigger types, ETS Rising or falling edge
Digital triggering provides 1 LSB accuracy up to full bandwidth
Trigger sensitivity In ETS mode, typical 10 mV p-p at full bandwidth
Maximum pre-trigger capture 100% of capture size
Maximum post-trigger delay 4 billion samples
Trigger re-arm time PC-dependent < 2 μs on fastest timebase
Maximum trigger rate PC-dependent Up to 32 waveforms in a 64 μs burst
FUNCTION GENERATOR
Standard output signals Sine, square, triangle, DC voltage, ramp, sinc, Gaussian, half-sine
Pseudorandom output signals None White noise, PRBS
Standard signal frequency DC to 100 kHz DC to 1 MHz
Sweep modes Up, down, dual with selectable start/stop frequencies and increments
Free-run or up to 1 billion waveform cycles or frequency sweeps.
Triggering - Triggered from scope trigger or manually.
Output frequency accuracy ±100 ppm ±50 ppm
Output frequency resolution < 0.01 Hz
Output voltage range ±2 V
Output adjustments Any amplitude and offset within ±2 V range
Amplitude flatness (typical) < 1 dB to 100 kHz < 0.5 dB to 1 MHz
DC accuracy ±1% of full scale
SFDR (typical) > 55 dB at 1 kHz full-scale sine wave > 60 dB at 10 kHz full-scale sine wave
Output characteristics Front panel BNC, 600 Ω output impedance
Overvoltage protection ±10 V
AUTOMATIC MEASUREMENTS
AC RMS, true RMS, cycle time, DC average, duty cycle, falling rate, fall time, frequency, high pulse width,
Scope mode low pulse width, maximum, minimum, peak to peak, rise time, rising rate.
Frequency at peak, amplitude at peak, average amplitude at peak,
Spectrum mode total power, THD %, THD dB, THD plus noise, SFDR, SINAD, SNR, IMD
Statistics Minimum, maximum, average and standard deviation
SERIAL DECODING
Protocols CAN, LIN, I²C, UART/RS-232, SPI, I²S, FlexRay
DISPLAY
Interpolation Linear or sin(x)/x
Persistence modes Digital color, analog intensity, custom, or none
GENERAL
PC connectivity USB 2.0 (USB 1.1 and 3.0 compatible). USB cable included.
Power requirements Powered from USB port
Dimensions (including connectors) 142 x 92 x 19 mm
Weight < 0.2 kg (7 oz)
Temperature range Operating: 0 °C to 50 °C (20 °C to 30 °C for stated accuracy). Storage: –20 °C to +60 °C.
Humidity range Operating: 5% to 80% RH non-condensing. Storage: 5% to 95% RH non-condensing.
Safety approvals Designed to EN 61010-1:2010
Compliance RoHS, WEEE, and LVD compliant. Tested to meet EN61326-1:2006 and FCC Part 15 Subpart B.
Software included PicoScope 6, Windows and Linux SDK, example programs (C, Visual Basic, Excel VBA, LabVIEW)
PicoScope software PC requirements Microsoft Windows XP (SP3), Windows Vista, Windows 7 or Windows 8 (not Windows RT). 32- or 64-bit
Chinese (simplified & traditional), Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian,
Languages Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Romanian, Russian, Spanish, Swedish, Turkish
Probes
Two x1/x10 passive probes are included,
chosen to match the bandwidth of your
scope.
Ch A PicoScope Probes included Order
model (kits PP906 to PP910) code
Ch B
Arbitrary waveform 2204A
generator 2205A 60 MHz probes (2) MI007
2206A
2207A 150 MHz probes (2) TA132
2208A 250 MHz probes (2) TA131
Hand-held oscilloscopes
Also available in the PicoScope 2000
Series, the PicoScope 2104 and 2105
single‑channel hand‑held oscilloscopes are
the ultimate in compact design.
USB port See www.picotech.com for details.
Ordering information
UK headquarters: US headquarters:
Pico Technology Pico Technology
James House 320 N Glenwood Blvd
Colmworth Business Park Tyler
St. Neots Texas 75702
Cambridgeshire United States
PE19 8YP
United Kingdom
+44 (0) 1480 396 395 +1 800 591 2796
+44 (0) 1480 396 296 +1 620 272 0981
[email protected] [email protected]