Mobile Refueling Equipment Evaluation Form
Mobile Refueling Equipment Evaluation Form
_____ ________ Has received hands-on training, demonstrates proficiency, and can discuss the purpose, relevant
safety features, proper operation, inspection of and, if responsible, the proper maintenance and
maintenance frequency for the following:
☐Checks brakes by coming to a complete stop approximately 50’ from the aircraft
before proceeding and limits speed to no greater than 5-10 MPH
☐Positioning
☐Parks refueler in a manner providing at least 10’ of clearance away from aircraft
engines and fuel vents
☐Positions refueler with a clear path for exiting in the event of an emergency
☐Parks where gauges on the refueler/aircraft are visible during the fueling process
☐Chocks wheel(s) before beginning the fueling process and whenever refueler truck is
parked
1
☐Backing/Reversing
☐After correctly positioning refueler, setting brakes and chocking truck trainee:
☐Engages PTO
☐Opens the reel inlet valve and unwinds enough hose to reach the aircraft (should be
carried over-the-shoulder)
☐Is cautious to not insert nozzle spout too far into the wing
☐Supports fuel hose and nozzle to prevent damage to the wing and the port’s filler neck
☐Observes fuel meter to ensure accuracy of delivery and periodically checks fuel level
in tank so as not to overfill
☐Alternates wing tanks to prevent tipping plane if too much fuel is given to one side of
aircraft before switching to the other wing; and when topping-off an aircraft to ensure
maximum fill capabilities. Understands “Duel” overwing fueling responsibilities when
applicable.
☐Disengages PTO
2
☐Closes product belly valve/emergency internal valve
☐Applies service brakes and releases park brake before moving refueler
☐Knows company procedure to follow if uncertain how to service a particular type of aircraft
☐After correctly positioning refueler, setting brakes and chocking truck trainee:
☐Engages PTO
☐Opens the reel inlet valve and unwinds enough hose to reach the aircraft fueling
adapter
☐Removes dust cover and connects to the aircraft fueling adapter then opens nozzle
☐Removes deadman handle from its receptacle and a sufficient length of cord
☐Stands in a location where it is possible to observe aircraft fuel gauges, meter and other
gauges on the refuel truck
☐Rewinds the deadman hose and stows the deadman in its receptacle
3
☐Closes product belly valve/emergency internal valve
☐Closes the nozzle and disconnects it from the aircraft fueling adapter
☐Returns any switches to their original position on the aircraft and secures any service
panels accessed during fueling in their closed and locked position
☐Applies service brakes and releases park brake before moving refueler
☐Knows company procedure to follow if uncertain how to service a particular type of aircraft
_____ ________ ☐Fuel Transfers Between Fuel Storage Systems and Refueler Trucks
☐Has verified that deadman control and safety shutoff devices are working properly and that all
other daily inspections have been performed on the fuel storage system before beginning any fuel
transfers
☐Bonds refueler truck to the fuel storage system before making any other connections
☐Opens the bottom load gate on the truck and connects the fuel storage transfer nozzle to the
bottom loading adapter on the truck
4
☐Opens the shutoff valve behind the bottom loading adapter and positions the loading nozzle
handle to open position to allow fuel to flow
☐Correctly positions storage system valves for transferring fuel to the refuel truck
☐Engages the deadman to begin fuel transfer and starts and stops the deadman to test for proper
function
☐Properly performs “pre-check” test to ensure high level shutoff is working on the truck
☐Continues fuel transfer if “pre-check” test confirmed proper function of high level shutoff
☐Once fuel transfer is complete returns the “pre-check” valve to normal position and closes
shutoff valve behind the bottom load adapter
☐Closes valve on loading hose and disconnects from bottom load adapter, replaces dust cover
☐Replaces dust cover on bottom load adapter and closes bottom load gate on refuel truck
☐Applies service brakes and releases park brake before moving refueler
☐Trainee has been trained regarding the following top loading concerns and safety practices:
☐”Splash” loading without a drop tube is not allowed because of the potential
for static discharge in the vapor space of the tank
☐Is aware of potentially dangerous fumes emitted during the transfer from the open
manway
5
_____ ________ ☐Mobile Refueler Truck Components and Inspection Procedures
☐Internal/Belly Valve(s)
☐Trainee can locate the internal valve(s) and discuss how they
function in the following circumstances:
☐Trainee can explain how the internal valve functions/opens during bottom
loading
☐Trainee can explain what the pre-check is and what the high level
shutoff does
☐Trainee understands and can discuss how the additive injection system works
☐Trainee checks additive reservoir at the start of shift prior to using the refueler
and knows local procedure to follow if additive level is too low
☐Trainee can assess the condition of desiccant dryer on additive reservoir and
knows local procedure to follow if it needs replacing
☐Trainee knows how this very important safety feature works to shut down the
flow of fuel in the event of an emergency and how to test the system on all
equipment used.
6
☐Tanker Vent(s) and Dome Cover
☐Trainee knows how vents operate during the dispensing or receiving of fuel
and how a dome cover needs to face forward so that movement of the truck
would cause it to close if accidentally left open; must be a double latching
system
☐Trainee can explain the function of the PTO and its relation to the product
pump
☐Trainee can identify, engage and disengage the pumping systems on all FBO
refueling equipment
☐Trainee can identify the primary means of pressure control on the truck and
knows its set point (to determine if a failure has occurred)
☐Trainee can identify the secondary means of pressure control and knows its
set point (to determine if a failure has occurred)
☐Trainee can explain the situations in which a refueler should not move:
☐When a hose is connected to the bottom loading point (or the bottom
loading gate is open)
☐Trainee knows location and operation of brake interlock override in the event
of an emergency (override should be sealed with breakaway safety wire in the
normal position- any tampering needs to be reported)
☐Exhaust Systems with Diesel Oxidation Catalyst (DOC) & Diesel Particulate Filter
(DPF) (if equipped):
☐Trainee has been trained per NFPA 407 requirements and local authority
guidelines/ procedures for the safe regeneration of FBO vehicles equipped with
DOC/DPF
7
☐Understands the importance of regular refueler maintenance (engine, transmission, pump, axels,
swivels, additive injectors, and air dryers etc., to be maintained per manufacturer’s instructions at
recommended maintenance intervals), thorough record keeping and how to perform the following
inspections at their designated frequency:
☐Daily Inspections
☐General Condition (under-inflated tires; tire tread worn below a safe limit;
cracks in mirrors or windows; proper function of horns, lights, beacons; leaks on
chassis, engine, transmission or axels; properly functioning engine gauges;
functioning wipers; working parking and service brakes; no excess play in
steering wheel; placards visible, etc.)
☐Sump Filter Vessel (can properly perform, rate and record a sump sample
with the vessel under pressure)
☐Tank Sump(s) (can properly perform, rate and record a tank sump sample
from all low points ensuring truck is parked on a level surface prior to sampling)
☐Brake (Safety) Interlocks (tests the function of each interlock prior to shift
and reports any deficiencies)
☐Nozzle Fueling Pressure-PSI (records Jet-A truck nozzle pressure on first fuel
transfer of the day from refueler into aircraft, or via recirculation prior to first
fueling use, to ensure pressure control is functioning at or below primary 40 PSI
setting during single point refueling operations)
☐Nozzles (inspects single point/underwing for nicks and cracks on the nose
seal, ensures overwing nozzles are in place, flared spout for jet and smaller
round for avgas, checking all for excessive wear, sharps edges, loose
components, bonding clips and cables, ensures dust covers are used and 100
mesh screens are in place)
8
☐Ground Reels, Cables and Clamps (checks grounding reels, cables and clamps
for damage, tightness and corrosion; checks integrity of connection to grounding
rod; repair/replace defective equipment promptly)
☐Fire Extinguisher(s) (knows that NFPA 407 requires two 20 B:C rated
extinguishers one on each side of the truck; ensures they are visible and
unobstructed for ease of use with seals intact and no evidence of low charge;
knows to remove deficient extinguisher from service and not to use refueler until
replaced)
☐Tanker Troughs & Drains (checks to ensure there is no standing water in the
trough; if water is found, checks drain tubes to ensure there is no obstruction
which could allow water to accumulate and contaminate the fuel)
☐Air Tanks (drains air supply tanks daily to purge system of moisture that can
cause failures in air operated components)
☐Spill Kit (checks to make sure kit is provisioned with a full complement of
absorbent materials to contain and clean a fuel spill)
☐Surge Tank Sump (if equipped- safety device found on some refuelers that
pump over 600 gpm to help minimize static accumulation that can occur at
higher flow rates; sump the vessel discarding any visible contaminants)
☐Fuel Leaks (checks for visible drips or evidence of staining around couplers,
flanges, joints, bottom loading connection point, piping, valves, pumps, nozzles,
filter vessels, meters and hoses reporting them for repair)
☐Weekly Inspections
☐Belts, Hoses and Tires (checks integrity of chassis belts, hoses and vehicle
tires)
9
☐Fluid Levels (ensure adequate levels of coolant, brake and power steering
fluid)
☐Lights, Lenses and Beacon (checks function of all lights-head, tail, running
and brake lights, turn signal indicators; lenses intact, no exposed bulbs or
wiring; rotating beacon function)
☐Monthly Inspections
☐Nozzle Screens (inspects and cleans 100 micron mesh screens; can identify
contaminants and their probable source, example rubber pieces could be from
hose lining, seals, gaskets, etc.)
☐Fuel Hose(s) (pulls hose its full length off the reel and inspects it under
pressure for cracking, abrasions, cuts, soft spots, blisters, chaffing, twists, sharp
ends or other irregularities; checks coupling indicator for slippage)
☐Meter Seals (inspects to ensure meter calibration tag is current and seals are
intact)
10
☐Tanker Interior (performs visual inspection of tank interior (visually inspects
tank interior for rust, sediment, foreign objects, and tank lining defects- if
applicable, using a hand-held mirror)
☐Has been trained per local requirements regarding any PPE, safety
gear, fall protection, etc., necessary for performing this inspection
☐Tanker Vent(s) and Dome Cover (checks vent screen for damage, with PTO
engaged inspect vent for proper function; inspects vent for proper function
during bottom load; inspect dome cover gaskets for deterioration, cracks or other
damage; check proper orientation of lid)
☐Tanker Troughs and Drains (drops a penny down each drain tube to ensure
tubes are free of any obstruction)
☐Internal Valve Integrity Check (tests the belly valve to ensure complete
closure per NFPA 407)
☐Quarterly Inspections
☐Vehicle Inspection (Lubricate all systems, check all fluid levels including
PTO gear box; check pinion seals, wheel seals, axle flanges for leaks; service
and tune the engine per manufacturer’s recommendations)
☐Water Defense External Check (shuts down the pumping system when they
encounter a slug of water; Float operated type with external mechanical test
feature are tested by depressing plunger to simulate a slug of water to verify that
fuel flow ceases)
☐Brake Interlock Override (with an interlock actuated- verify truck will move
when interlock override is activated; reseal when testing complete)
☐Annual Inspections
11
☐Water Defense System (must be tested by injecting water to ensure
functionality using manufacturer guidelines-typically performed just prior to
annual filter change out: Never inject water into monitor type elements)
☐Fire Extinguisher Certifications (has licensed contractor certify and tag fire
extinguishers for use)
Remarks: ______________________________________________________________________________________
______________________________________________________________________________________________
______________________________________________________________________________________________
______________________________________________________________________________________________
______________________________________________________________________________________________
12