This short guide provides an overview of the basic functions and connections for the SIMOVERT MASTERDRIVES CUVC. It includes references to the operating instruction and diagrams for power connections, control connections, and control commands. Parameters are explained for drive setting, operation via the PMU, monitoring parameters, and quick parameterizing. Connections are detailed for the line, motor, setpoints/analog outputs, and speed/analog inputs.

Uploaded by

Fida Hussain
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
161 views

Siemens VC Default

This short guide provides an overview of the basic functions and connections for the SIMOVERT MASTERDRIVES CUVC. It includes references to the operating instruction and diagrams for power connections, control connections, and control commands. Parameters are explained for drive setting, operation via the PMU, monitoring parameters, and quick parameterizing. Connections are detailed for the line, motor, setpoints/analog outputs, and speed/analog inputs.

Uploaded by

Fida Hussain
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

SIMOVERT MASTERDRIVES CUVC Short Guide to the Basic Functions

(Please pay attention to the Operating Instruction (BA) chapter and diagram references)

General: Connections 1 Connections 2


BA = Operating instruction (BA Power Connections): (BA Control Connections): Control commands:
WR = Inverter
PW = Pulse resistor or Default for
regenerative feedback Line 24V H X101.1 P368 = 1 P368=0,7
BEx = Binary input Terminal strip PMU, OP1S
0V L .2
BAx = Binary output 20mA
AEx = Analog input BA1 (BE1) .3 P651 =B107 No fault =B107
AAx = Analog output 20mA .4 P652 =B104 Operation =B104
PMU BA2 (BE2)
Bxxx = Number of a binary signal
(binector) B0=0, B1=1 20mA BA3 (BE3) .5 P653 =B115 No alarm BE3 P590=14
X101
Kxxx = Number of an analog signal (BA4) BE4 .6 B016 INV enable P561=16 P561=1
(connector) K0=0%, K1=100% X102
Pxxx = Number of a parameter BE5 .7 B018 ACK P567=18 P567=0
(Index = 1, if present and X103 BE6 .8 B020 OFF2 P555=20 P555=1
not otherwise designated)
BE7 .9 B022 ON/OFF1 P554=22 P554=5, 2100
Ref. values for analog signals:
2 wire  RS 485 P .10 1 3 Switch S2 IMPORTANT:
Motor
10 V = 100 % Ref Value If present: USS (SST2)  Dual connecting
P350 = Ref Amps set fan  RS 485 N .11
P352 = Ref Frequency of terminals
transformer to RS 485 ref .12 2 4
P353 = Ref Speed Bus termination X101.3 ... .6 as
line voltage
P353 = P352 * 60 / No. of pole pairs BAx and BEx
(BA Fan fuse)
Ref values can be changed only in not allowed!
+10 V 5 mA X102.13
P60=5 Drive Setting Setpoints / analog outputs are shown below
-10 V 5 mA .14
Parameterizing
±10 V AE1 .15 K11 3 Switch S3
1 P632.1, .2
(BA Parameterizing):
open: ± 10 V 0
•009
v/f characteristics:
Operator display 0V AE1 .16
(P100=0, 1, 2) 0 ... 10 V 1
005 : Drive setting
Diagram r0, r1, r2 ±10 V AE2 .17 K13 closed: ± 20 mA 2
008 : Switch-on inhibit 4 2
Operation via BA Quick 0 ... 20 mA 3
↓ P
↑ 009 : Ready for switching on
014 : Operation PMU: parameterizing 0V AE2 .18 AE2 AE1 4 ... 20 mA 4
I/O
P554 = B005 ±10 V, 5 mA AA1 .19 P640.1 3 6 Switch S4
Speed left : ± 10 V
r000
P
Monitoring Acknowledge fault 0V AA1 .20
P101

parameters P330=0 right : ± 20 mA


P571 = B006 M = const. ±10 V, 5 mA AA2 .21 P640.2 20 ... 0 mA
I
P572 = B007 Current 1 2 4 5 20 ... 4 mA
0V AA2 .22 AA1 AA2
P060
O P
Variable P573 = B008 Current outputs with
P325

parameters X300
P574 = B009 reversed sign
P 0V X103.23 Calculation: Diagram a0
Index (not Operation via Track A .24
f Note:
all parameters) OP1S: P326 P293 Track B .25 The screen of the tacho lead
T
P I/O P554 = B2100 must be earthed to the motor
Zero pulse .26
and converter housings over a
P101

P565 = B2107
1
R
Change Fault P330 = 1
Run
M ~ n2 Control input .27 wide area.
parameter Jog P568 = B2108
value
I
+ 15 V 190mA .28
0 P P571 = B2111 In P60=5 (Drive setting):
.29 P130=11=Pulse encoder
P325

7 8 9 P572 = B2112 Motor


5 4
1
5
2
6
3
P573 = B2113 temperature .30 P151=Increment (1024)
0 +/- P574 = B2114 PTC KTY84 sensor
P Save new f
value P380 = 1°C P380 = Alarm temp. in °C
For binectors: see control commands P293
P381 = 1°C P381 = Fault temp. in °C

Quick parameterization (BA Parameterizing steps) P382, P383 for i²t calculation with ROTEC induction motors (P95 = 2, P97 > 0) assigned automatically.
°021 P382: Motor Cooling (0=self-ventilated, 1=separately ventilated)
P060: Menu Select → 3 indications: P383: Motor thermal time constant (0s=n protection; value ≥ 100s: Table BA Quick parameterization)
P071: Line Volts (AC or DC, depending on unit) P370: Start quick parameterization → 1 (All reference values P350. .P354 are set to motor rated values)
P095: Type of Motor (IEC=10 NEMA=11 ROTEC=02 *) P60=0 (User menu)
P097: Motor Number --- --- 1PH7(=1PA6) 1PL6 1PH4 Type of t( 1=v/f curve; 2=v/f curve, textile; 3=Vector ctrl without encoder (f-Reg.); 4=Vector control with pulse encoder )
P100: Control Mode see right see right see right control (diagram r1) (diagram r2) (diagram r3) (diagram r4)
P101: Motor Rtd V Voltage (V) Voltage (V) ---
P102: Motor Rtd A Current (A) Current (A) --- P462 : Acceleration time on P352=reference frequency or P353=reference speed
P104: MotPwrFactor cos PHI --- --- P464 : Deceleration time on P352 or P353 on 0Hz
P105: Mot Rtd Power --- Power (hp) --- P60= 5 (Drive setting)
P106: Mot Rtd Effic. --- Efficiency % --- P330 : v/f type of characteristic -> 0=linear,
P107: Mot Rtd Freq Frequency Frequency (Hz) --- 1=parabolic (pump, fan) Fans, pumps in the case of vector control (P60=1):
P108: Mot Rtd Speed Speed Speed (1/min) --- see P291, P295, P303
P109: Motor #PolePairs is automatically calculated from P107 and P108 P452 : Maximum frequency FWD speed in % of P352 or P353 PMU displays by P
P114: Technol. Cond. (vector control only) = Standard → 0 P453 : Maximum frequency REV speed in % of P352 or P353 and I key:
with pumps/fans: = Part-load optimization → 5 P60=0 (User menu)
Motor identification at standstill (motor gets organized): P115=2* (also in the case of v/f characteristic) P A078 °009 I °018 °009

P368: Setpoint source 0 = PMU + motor potentiometer (diagram s0); Unit is ready for power up from now onwards
1 = Analog input + terminal strip (diagram s1); No-load measurement (motor rotating !): P115=4* ( not in the case of v/f characteristic) P A080 °009 I °019 °009
7 = OPS1 + Fixed setpoints (diagrams s7 and s71) Controller optimization (if no gear backlash !): P115=5* ( not in the case of v/f characteristic ) P A080 °009 I °019 °009
continued at right P471 : Precontrol, acceleration *The ON command must be given within 20s!
* List for ROTEC induction motors in BA Quick Parameterization

When P60=1 (parameter menü) more parameters are accessible than on diagrams ax, sx, rx of the BA (P60=0).
Further parameters (P60 = 0 = user menu): Further parameters (P60 = 1 = parameter menu): Further parameters (P60 = 1):
Parameters visible when P60=0 are defined in P360 Deceleration time for quick stop (OFF3) P466 in s Motor load limits i²t (i001=alarm,i002=fault) P384.x in %
Prot ramp gen. gain Kp (P100<=3, f<15%) P467 Flying restart (e.g. for fans) P583 (1=ON)
Current limitation P128 in A Ramp end/ramp start smooth P469 P470 in s Fly search speed P526 in Hz/s
Slip compensation (P100=1) P336 in % Minimum frequency P457 in % * DC bus volts reg. (if no pulse resistor) P515 (1=ON)
Static/dyn. torque (P100=3) P278/P279 in % * Skip frequency P455 in % * Frequency limit for turn-off value OFF1 P800 in % *
defines the current magnitude at f<10% Fixed setpoint 5 in Hz (K045) P405 in Hz
Torque limits (P100=3,4) P492/P498 in % * Excitation/de-magnetize time P602 P603 in s * % values are referred to P352, P353 or P354/P113
Speed controller Kp, Tn (P100=0,3,4) P235 P240 in ms

Control commands: Default for... (P368=0 diagrm s0) (P368=1 s1) (P368=7 diag s7) Setpoints: Default for... (368=0 diag. s0) (368=1 diag. s1) (368=7 diag. s71)
ON/OFF1 command P554 B005 (PMU) B022 (BE7) B2100 Main setpoint P443 = K058 K011 = Analog input1 K040 = Fxd setpoint
Coast (OFF2) P555, 556, 557 B001 = 1 B020 (BE6) 1 (=Motor pot.) (K013 = AE2) (P405=FSW 5 in Hz
Quick stop (OFF3) P558, 559, 560 1 1 1 & P417=1)
INV release P561 1 B016 (BE4) 1 Additional setpoint 1: P433 (P401=FSW 1 in %
Setpoint release P564 1 1 1 & P417=0)
Fault reset P565, 566, 567 B2107 (OP1S) B018 (BE5) B2107 Analog outputs P640.x (Index 1: AA 1; Index 2: AA 2) (see diagram a0 of Operating Instruction):
Jog (n/f: P448 in %) P568 B000 = 0 0 B2108 Default setting: P640.1 = speed = K148 (Speed n: P002 in Hz (K020))
FWD speed P571 1 (B006 = PMU) 1 B2111 P640.2 = output current = K022 (Current I: P004 in A (K022))
REV speed P572 1 (B007 = PMU) 1 B2112 Gain: P643.x Output voltage Ua: P003 in V (K021)
Motor pot. raise P573 B008 (PMU) 0 0 Offset: P644.x DC link voltage Ud: P006 in V (K025)
Motor pot. lower P574 B009 (PMU) 0 0
External fault P575 1 1 1 The control command defaults in the cass of P368=0 apply when:
BE3=0=BICO data set 1=basic data set!
Note: 0 = continuous 0 = L = 0V = terminal X101.2; 1 = continuous 1 = H = 24V = terminal X101.1 BICO data set changeover (basic/reserve data set): P590 = B014 = BE3
Example: ON/OFF1 command (P554) setpoint source P368=1 from BE7 (binector B022): P554=22 BA3 can only be used when P590=0 ! BE3 can only be used when P653=0 !

Problems? - Fault : Indication Fxxx (see Operating Instruction, Faults)


- Drive does not behave as it should: Reset : Clear the cause of the fault, then P
Parameter settings lost; repeat quick parameterization (contains factory settings); Check motor rating Return to parameterizing level : Press P and at the same time
plate data and type of connection (e.g.star/delta); then reset parameters.
- Drive does not start: - Alarm : Indication Axxx (see Operating Instruction, Alarms)
Where P100=1, 2 : Use P325 to increase the voltage boost at 0 Hz. Disappears automatically when the cause has been eliminated.
Where P100=3 : Use P278,P279 to increase the current at low speeds, or increase P467 The diagrams in the Operating instruction for quick parameterization refer to the detailed
Where P100=3,4 : Use P492 to increase the torque limit. If P100=4: check tachometer wiring diagrams of all functions and parameters in the "Compendium", e.g.: Sheet 90 terminal strip