DATA SHEET

CHECKFIRE 210
Detection and
Actuation System

Features
n Supervised power, detection, release, and communication
circuits
n Display module with LED system status indicators

n Adjustable mounting bracket (display module)

n 85 dB internal sounder

n Compact size

n Automatic and/or manual actuation

n Electric DELAY/Reset/Silence button


n PUSH To Activate / Alarm When Lit electric
manual activation button
n Interface control module for all color-coded Plug and Play
cable connections
n Cables provide quick installation and easy replacement

n Internal power source with optional external power 009266

n Auxiliary power output when external power is connected

n Manual programming at interface control module Application


n Computer programming available through mini USB port The CHECKFIRE 210 Detection and Actuation System is typically
n Two programmable release time delays used with an ANSUL® A-101 or LVS Vehicle Fire Suppression
System for 24-hour protection of equipment. The system is
n Two analog detection circuits designed for vehicles and equipment in extreme environmental
n Detection circuits are programmable for multiple detection and physical conditions.
methods
Industries where vehicles use CHECKFIRE 210 Systems:
n Detection circuit #2 may be programmed for pressure switch
n Forestry n Land fills
feedback
n Agriculture n Waste disposal
n Two internal programmable SPDT Form C relays
n Construction n Mining
(5 A @ 30 VDC nominal automotive)
n Public transportation
n Downloadable 4000+ event history log with real-time stamp
n Public utilities
n System isolate feature

n Dust and water tight (IP67 rated)


Description
n Designed for harsh environments
The CHECKFIRE 210 Automatic Detection and Actuation System
provides supervised input/output circuits to activate an ANSUL
fire suppression system. Upon detecting a fire condition, the
interface control module activates the release circuit, result-
ing in the discharge of an expellant gas cartridge, initiating fire
suppression system operation.
Green, amber, and/or red pulsing LEDs, and the internal sounder
notify operator of system status. The sounder only activates for
faults, isolate mode, and system release.
Operating components include the display module, interface
control module, spot thermal detectors, linear detectors, electric
manual actuators, protracting actuation devices (PAD), electric-
pneumatic actuators, and cables for power, detection, and
release circuits. The entire system is electronics based for super-
vision, communication, and control of system components.

One Stanton Street  |  Marinette, WI 54143-2542, USA  | +1-715-735-7411 | www.ansul.com


© 2017 Johnson Controls. All rights reserved. All specifications and other information shown were
current as of document revision date and are subject to change without notice.  |  Form No. F-2014011-01
CHECKFIRE 210 System – Sample Connections
LINEAR
DETECTOR

BRANCH TERMINATOR
(ON END OF DETECTOR)

CHECKFIRE 210
SPOT THERMAL ELECTRIC MANUAL DISPLAY MODULE
DETECTORS (INSTALL ACTUATOR AND BRACKET
WITH HEAT SHIELD AND BRACKET
AND BRACKET)

DETECTION
CIRCUIT
CABLE
EOL AND TEES
DEVICE

DISPLAY
VISUAL CABLE
SEAL
INTERFACE
CONTROL
MODULE

POWER CIRCUIT FUSED POWER


CABLE CIRCUIT CABLE

RELEASE CIRCUIT
DROP CABLE

RELAY CIRCUIT
RELEASE CIRCUIT
CABLE
ELECTRIC- CABLE AND TEES
PNEUMATIC RELAY
ACTUATOR CABLE-LEADS

EXPELLANT
GAS
CARTRIDGE

AGENT
TANK
009269
Typical System Connections Display Module
The CHECKFIRE 210 Display Module communicates with the The CHECKFIRE 210 Display Module communicates with the
CHECKFIRE 210 Interface Control Module (ICM) through the Interface Control Module (ICM) to indicate system status.
display cable using threaded circular connectors. Color-coded Installation within reach of the operator provides easy access to
receptacles in the ICM are the central connection point for all operator controls.
system cables.
GUARD
System Cabling: Enables communication and control of DOOR
components.
n IP67 connectors

n Color-coded, anti-vibration connections RELEASE ANSUL ® POWER


CHECKFIRE 210
n Integral connectors on each end of cable CONTROL SYSTEM
DISCHARGE
DETECTION
n Multiple lengths for versatility
DELAY PUSH
RELEASE TO ACTIVATE
n Temperature rating: 302 °F (150 °C) ISOLATE

Detection Circuits #1 and #2: Permits multiple-detection options


SHUTDOWN
using detection circuit cable and tees for the main detection
trunk and branch lines.
n Electric manual actuators 009270

n Linear detectors
DELAY/RESET/ PUSH TO ACTIVATE/
n Spot thermal detectors SILENCE BUTTON ALARM WHEN LIT
BUTTON AND LED
n Pressure switch (detection circuit #2 only)

Release Circuit: Connects to a maximum of 10 electric-pneu- n Dust and water tight (IP67 rated)
matic actuators installed on agent tank expellant gas cartridges
using release circuit cable(s), tee(s), and release circuit drop n Durable high-strength glass-filled nylon material
cable(s). n Surface or bracket mounted

External Power Circuit: Provides a direct connection to the n Two index pins on back for secure mounting
vehicle power source using power circuit cable(s) and a single n Ambient temperature range: -40 °F to 185 °F (-40 °C to 85 °C)
fused power circuit cable, when external power is required.
n LED indicators provide notification of system status (internal
Auxiliary Output Circuit: Connects to external notification sounder matches LED pulse rate)
devices.
n PUSH To Activate / Alarm When Lit manual-activation button
Display Circuit: Connects display module with ICM. and LED
Relay Circuit: Provides connection for two independent internal – Provides manual actuation (immediate release)
relay contacts for connection by others. – Indicates alarm condition
n Guard door with visual seal to protect manual-activation
button
Detection n DELAY/Reset/Silence Button
A Linear Detector with an activation temperature rating of
– Restarts Time Delay #1 (TD1) before TD1 sequence expires
356 °F (180 °C) provides fire detection in the protected area. Two
twisted spring steel conductors separated by a heat-sensitive – Resets system (during non-alarm status)
insulator are limited to a minimum bend radius of 2 1/2 in. (64 –S
 ilences internal sounder during fault conditions and isolate
mm). For easy installation, red color-coded connectors match mode
the red connectors of the entire detection circuit.
Spot Thermal Detectors have the temperature rating stamped
on the detector and are color-coded blue for 250 °F (121 °C) and
red for 350 °F (177 °C) operating temperatures. The included
retaining nut securely holds the detector in the required bracket
and heat shield.
Interface Control Module (ICM)
The CHECKFIRE 210 Interface Control Module (ICM) is
the central connection point for input/output circuits.
Through communication with the display module,
operators receive continuous system status updates,
and operator input commands go directly to the ICM.
Color-coded receptacles match with color-coded cable
connectors providing quick visual confirmation of
proper circuit connections.

BATTERY
COMPARTMENT

009267
ISOLATE
SWITCH
Battery Module
A supervised 3.6 VDC lithium CHECKFIRE 210 Battery
Module provides internal power for the CHECKFIRE
210 System. A connector pigtail extending from the
top of the battery connects to the ICM battery cable.
COLOR-CODED
RECEPTACLES (7
PLACES) 009271

Electric-Pneumatic Actuator
With a focus on ease of installation and safety, the
Electric-Pneumatic Actuator reduces system complex-
The protective battery compartment cover is held ity. The Protracting Actuation Device (PAD) directly
in place with 4 captive screws. Besides the internal actuates the electric-pneumatic actuator pin eliminat-
power supply, the battery compartment includes ing the need for pneumatic actuation.
the battery cable, a mini USB connection port, and
the programming interface (button and LEDs). The The re-designed PAD with plug-in spade connectors
system programming may be accomplished with the is easy to install and replace without tools. After plug-
manual programming button and indicator LEDs or ging the PAD into the release circuit drop cable, the
by using a computer with the ANSUL CHECKFIRE 210 cable is hand-tighted to the top of the electric-pneu-
Programmer software communicating through the matic actuator.
mini USB port.
An isolate switch on the side of the ICM provides ease
of access to temporarily disable the automatic system
release function. While disabled, manual system
release is still available. An amber isolate LED on the
display module continues to pulse until the switch is
returned to normal.
n Dust and water tight (IP67 rated)

n Durable high-strength glass-filled nylon

n UL94 Flame rating 009261

n Ambient temperature range: -40 °F to 185 °F For installer safety during assembly of the Electric-
(-40 °C to 85 °C) Pneumatic Actuator to an expellant gas cartridge,
the actuator includes a new preventor. The integral
n Internal battery compartment with IP67 cover
preventor reduces the possibility of attaching the
n System isolate switch actuator with the pin not completely retracted. It also
n Steel mounting plate provides a metal to metal seat with the expellant gas
cartridge eliminating the spacing washer.
If required, optional pneumatic actuation is available.
Electric Manual Actuator System Specifications
The newly designed Electric Manual Actuator (EMA) Interface Control
provides electrical activation of the fire suppression Module Power: Internal power source
system. Pulling the pin and striking the red button and/or: 12/24 VDC nominal
sends a signal to the interface control module for external power
immediate actuation of the electric-pneumatic actua- (24 hour operation)
tor. Upon actuation, the expellant gas cartridge initi- Operating
ates fire suppression system operation. Temperature Range: -40 °F to 185 °F
(-40 °C to 85 °C)
Shock: In accordance with UL1254
Vibration: In accordance with UL1254
Moisture and Dust: IP67 per IEC 60529
Electromagnetic
Compatibility: Heavy Industrial EMC Directive
Compliant (2004/108/EC)

Approvals
FM Approved and CE Marked

Note: The converted values in this document are provided


for dimensional reference only and do not reflect an actual
measurement.
009262 ANSUL, CHECKFIRE, and the product names listed in this
material are marks and/or registered marks. Unauthorized use is
EMAs are typically accessible from ground level and/ strictly prohibited.
or in a path of egress. An index nub ensures the EMA
remains at the proper angle for access to the pull pin.

009268
Ordering Information
Part No. Description
Part No. Description
Display Cables
System Components
439452 Cable, Display, 2 ft (0.61 m)
439560 Display Module, CHECKFIRE 210
439454 Cable, Display, 5 ft (1.53 m)
439564 Mounting Bracket, CHECKFIRE 110/210
439456 Cable, Display, 10 ft (3.05 m)
439561 Interface Control Module, CHECKFIRE 210
439458 Cable, Display, 20 ft (6.10 m)
439569 Electric-Pneumatic Actuator
(normally supplied with agent tanks) 439460 Cable, Display, 30 ft (9.15 m)
439400 Electric Manual Actuator (EMA) 439462 Cable, Display, 50 ft (15.24 m)
440537 Electric Manual Actuator Bracket 439449 Connector, Bulkhead, Display Cable

Detection Circuit Cables and Fittings Relay #1 & #2 Circuit Cable


439384 Cable, Detection Circuit, 2 ft (0.61 m) 439466 Cable, Relay Cable-Leads, 3 ft (0.91 m)
439386 Cable, Detection Circuit, 5 ft (1.53 m) 440410 Cable, Backup Power/Relay Circuit, 2 ft (0.61 m)
439388 Cable, Detection Circuit, 10 ft (3.05 m) 440413 Cable, Backup Power/Relay Circuit, 5 ft (1.53 m)
439390 Cable, Detection Circuit, 20 ft (6.10 m) 439482 Cable, Backup Power/Relay Circuit, 10 ft (3.05 m)
440759 Cable, Detection Circuit, 30 ft (9.15 m) 440416 Cable, Backup Power/Relay Circuit, 20 ft (6.10 m)
440762 Cable, Detection Circuit, 50 ft (15.24 m)
Auxiliary Output Circuit Cable
439394 Connector, Tee, Detection Circuit (MxFxF)
439450 Cable, Auxiliary Power Output Circuit, 3 ft (0.91 m)
439396 Connector, EOL Device, Detection Circuit
439398 Connector, Branch Terminator, Detection Circuit Power Circuit Cables and Fittings
439404 Connector, Bulkhead, Detection Circuit 439438 Cable, Power Circuit, 2 ft (0.61 m)
439440 Cable, Power Circuit, 5 ft (1.53 m)
Linear Detectors
439442 Cable, Power Circuit, 10 ft (3.05 m)
439406 Linear Detector, 2 ft (0.61 m)
439444 Cable, Power Circuit, 20 ft (6.10 m)
439478 Linear Detector, 5 ft (1.53 m)
439446 Cable, Power Circuit, 30 ft (9.15 m)
439480 Linear Detector, 10 ft (3.05 m)
440187 Cable, Power Circuit, 50 ft (15.24 m)
439408 Linear Detector, 20 ft (6.10 m)
439405 Connector, Bulkhead, Release and Power Circuits
439410 Linear Detector, 30 ft (9.15 m)
439492 Cable, Fused Power Circuit, (w/Inline Fuse Holder),
440765 Linear Detector, 50 ft (15.24 m) 3 ft (0.91 m)
Release Circuit Cables and Fittings Accessory Equipment
439418 Cable, Release Circuit, 2 ft (0.61 m) 440352 ICM Battery Module, CHECKFIRE 210
439420 Cable, Release Circuit, 5 ft (1.53 m) 438280 Spot Thermal Detector, 250 °F (121 °C)
439422 Cable, Release Circuit, 10 ft (3.05 m) 438281 Spot Thermal Detector, 350 °F (177 °C)
439424 Cable, Release Circuit, 20 ft (6.10 m) 440905 Spot Thermal Detector Bracket and Heat Shield
439426 Cable, Release Circuit, 30 ft (9.15 m)
439428 Cable, Release Circuit, 50 ft (15.24 m) 440389 Pressure Switch
439430 Cable, Release Circuit Drop, 30 in. (0.77 m)
440737 Double-Loop Cable Ties (Pkg. of 50)
439432 Cable, Release Circuit Drop, 38 in. (0.97 m)
56692 Rubber Sleeve (Pkg. of 20)
439434 Connector, Tee, Release Circuit (MxFxF)
439436 Connector, Release Circuit Terminator 440798 Label Package
439405 Connector, Bulkhead, Release and Power Circuits
439448 Protracting Actuation Device (PAD), 440097 Detection Circuit Tester (DCT)
w/Spade Connectors 441021 Release Circuit Tester (RCT)
440912 Release Circuit Test Plug (Pkg. of 3)