marlow industries inc.

®
Thermoelectric Cooler SP1848
Performance Values

Hot Side Temperature (°C) 27°C 50°C

∆ Tmax (°C-dry N2): 62.0 70.6

Qmax (watts): 21.3 23.6

Imax (amps): 9.36 9.24

Vmax (vdc): 3.48 3.88

AC Resistance (ohms): 0.323 ---

Mechanical Characteristics

1.130
[28.70] 1.000
[25.4]
1.000
[25.4] Cold
Side

Negative
.192 [4.88]
Positive
Hot Side

Ceramic Material: Alumina (AC)


Millimeters are in [ ]

Ordering Options

SP1848-00 with out lead wire


SP1848-03 with 4” lead wire

102-0132, Rev A
Thermoelectric Cooler SP1848
Performance Curves
Environment: One atmosphere dry nitrogen
Hot Side Temperature: 27°C Hot Side Temperature: 50°C

HEAT
80.0 80.0 LOAD
HEAT (WATTS)
LOAD
(WATTS) 0.00
60.0 0.00 60.0 2.50
2.50 5.00
T (C)

T (C)
5.00 7.50
40.0 40.0
7.50 10.0
10.0 12.5
20.0 12.5 20.0 15.0
15.0 17.5
17.5 20.0
0.0 20.0 0.0

4.0
3.0
VOLTAGE (VDC)

VOLTAGE (VDC)
3.0
2.0
Q=0 2.0
Q=0
1.0
T=0 T=0
1.0

0.0 0.0
0.0 2.0 4.0 6.0 8.0 10.0 12.0 0.0 2.0 4.0 6.0 8.0 10.0 12.0
CURRENT (AMPS) CURRENT (AMPS)

For performance information in a vacuum or with hot side temperatures other than 27°C or 50°C, consult one of our
Applications Engineers.

Installation

Recommended mounting methods: Bonding with thermal epoxy or soldering with metallized ceramics. For additional
information, please refer to our TEC Installation Guide.

Operation Cautions

For maximum reliability, storage and operation below 85°C in a non-condensing environment is recommended. To
minimize thermal stress, use linear/proportional temperature control or a similar method rather than an ON/OFF method.

Marlow Industries, Inc. Marlow Industries Europe Marlow Industries Asia


10451 Vista Park Road Aberdeen House, South Road 1-1-8-401
Dallas Texas 75238-1645 Haywards Heath Uehara, Shibuya-ku
TEL: 214-340-4900 West Sussex RH164NG UK Tokyo, Japan 151-0064
FAX: 214-341-5212 TEL: +44 (0)1444-443404 TEL: +81 (3) 5454-5280
Internet: http://www.marlow.com FAX: +44 (0)1444-443334 FAX: +81 (3) 5454-5281

Copyright 2002, Marlow Industries, Inc. Marlow Industries reserves the right to change the design and specifications of products without notice. 102-0132, Rev A