0% found this document useful (0 votes)
462 views

V16 Plus User Manual V1.2 1

This user manual provides instructions for operating the BLUGUARD V16 Plus home security and automation system. It describes keypad indicators, arming and disarming the system, bypassing zones, viewing troubles and alarms, using chime mode, and programming user codes, timers, and other system functions. The manual also outlines limitations of alarm systems and important warnings for safe usage.

Uploaded by

moorthysanmukam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
462 views

V16 Plus User Manual V1.2 1

This user manual provides instructions for operating the BLUGUARD V16 Plus home security and automation system. It describes keypad indicators, arming and disarming the system, bypassing zones, viewing troubles and alarms, using chime mode, and programming user codes, timers, and other system functions. The manual also outlines limitations of alarm systems and important warnings for safe usage.

Uploaded by

moorthysanmukam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 59

V16 Plus USER MANUAL

TABLE OF CONTENTS

1. INTRODUCTION………………………………………………………………………………... 2
2. TESTING…...................................................................................................................... 2
3. LIMITATIONS………………………………………………………………………………… … 2
4. WARNINGS……………………………………………………………………………………… 2
5. GLOSSARY……………………………………………………………………………………… 3
6. UNDERSTAND YOUR KEYPAD INDICATORS…………………………………………….. 4
7. SUMMARY OF OPERATION………………………………………………………………….. 6
8. TELEPHONY CONTROL DIAGRAM………………………………………………………….. 8
9. USER PROGRAMMING SUMMARY …………….…………………………………………... 9
10. ARMING THE SYSTEM……………………………………………………………….……….. 16
11. DISARMING THE SYSTEM……………………………………………………….…………… 20
12. TURN ON/OFF AUTOMATION POINT…..…………………………………………………… 22
13. BYPASS ZONE……………………………………………………..…………………………… 22
14. UN-BYPASS ZONE………………………….……………………..…………………………… 23
15. VIEW SYSTEM TROUBLE………………………………………...…………………………... 24
16. VIEW ALARM MEMORY……………………………………………………..………………… 25
17. CHIME MODE……..……………………………………………………..……………………… 25
18. EMERGENCY SITUATION….………………………………………………………….……… 26
19. PARTITIONING THE SYSTEM……………………………………………………..…………. 28
20. ARMING A PARTITIONED SYSTEM…………………………………………………….…… 28
21. PARTITION DISARMING…………….……………………………………………………… … 35
22. USER PROGARMMING MODE……………………………………………………..………… 36
23. EXIT USER PROGRAMMING MODE………………………………………………………… 37
24. PROGRAMMING NEW AND CHANGING EXISTING MASTER/USER CODE………….. 37

25. PROGRAM SYSTEM TIMER………………………………………………………….……. … 40


26. PROGRAM PARTITION 1 AUTO ARM TIMER…….……………………………….….…… 41
27. PROGRAM PARTITION 1 AUTO DISARM TIMER…….….……………………….….…… 43
28. PROGRAM PARTITION 2 AUTO ARM TIMER…….……………………………….….…… 45
29. PROGRAM PARTITION 2 AUTO DISARM TIMER…….….……………………….….…… 47
30. PROGRAM AUTO ON TIMER 1/2/3/4 FOR HOME AUTOMATION…….………………… 49
31. PROGRAM AUTO OFF TIMER 1/2/3/4 FOR HOME AUTOMATION…….………..……… 51

32. PROGRAM PERSONAL TELEPHONE NUMBER 1/2/3/4….…….………………………... 53


33. PROGRAM SYSTEM DATE………………………………………………………………… … 55
34. PROGRAM SECURITY AND HOME AUTOMATION TIMER SCHEDULE………………. 55

35. TESTING THE SYSTEM……………………………………………………..……………… … 56


36. SYSTEM INFORMATION……………………………………………………………………… 58

1
Version 1.2
V16 Plus USER MANUAL

INTRODUCTION

The BLUGUARD Control Panel is designed for simple operation yet provides the maximum protection
for you. Please read this manual carefully and follow the instructions contained in this book. Fill in the
system information page and store this manual in a safe place for future reference.

Your security system consists of a main control panel, one or more keypads and home automation
(HA) modules, various sensors and detectors. An enclosure will contain the control panel, which
includes the system electronics and standby battery.

TESTING
To ensure that your system is functioning, it is important that you test your system weekly. Please
refer to testing procedures section in this manual. If your system does not function properly, please
contact your system installer for services. There is normally no reason for anyone other than the
installer or service professional to have access to the control panel.

LIMITATIONS
Even though BLUGUARD is an advanced security system, it does not 100% guarantee the protection
against burglary, fire or other loses. Any alarm system whether commercial or residential is subjected
to compromise or failure-to-warn for a variety of reasons. These include:
 Intruders may gain access through unprotected openings or have the technical sophistication
to bypass an alarm sensor or disconnect an alarm warning device.
 Intrusion detectors, smoke detectors and many sensing devices will not operate without
power. Devices powered by AC will not work if there is no AC power supply for any reason
and the back-up battery is missing, dead or improperly installed.
 Alarm warning devices such as sirens may not alert people or wake up sleepers if they are
located on the other side of closed or partly closed doors.
 Telephone line needed to transmit alarm events from the premise to a central monitoring
station may be out or temporary out of service. Telephone line is subject to compromise by
sophisticated method of attack.
 Smoke detector used in conjunction with the alarm system may not sense fire that start from
where smoke cannot reach the detector such as wall, roof or the other side of the doors.
Smoke detector also may not sense a fire on another level of the residence or building. In
general, detectors may not always warn you about fire caused by carelessness and safety
hazards like smoking, violent explosions, escaping gas, improper storage of flammable
material, overloaded electrical circuits, children playing with matches.
 The most common cause of an alarm system not functioning properly when an intrusion or fire
occurs is inadequate maintenance. Therefore, your system should be tested weekly to ensure
all detectors or sensors are working properly.
 Installing an alarm system may make you eligible for lower insurance rates but an alarm
system is not a substitute for insurance. Homeowners, property owners and renters should
continue to insure their lives and properties.

WARNINGS
 A readily accessible disconnect device shall be incorporated external to the equipment
when installation.
 No operator’s replaceable batteries provided.
 The caution of replacement of battery provided in installation instructions for SERVICE
PERSON.
 CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY INCORRECT TYPE.
 CAUTION: DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
 The installation instructions require the external protective earthing green/yellow wire
must be at least 0.75mm2/18AWG complying with table 3B.

Note: All information is subject to changes without prior notice.

2
Version 1.2
V16 Plus USER MANUAL

GLOSSARY

Alarm Memory This is the history of the most recent violations that occurred the last time
when an alarm was triggered.

Arm To set the system into the ARMED mode. In this mode, a zone violation will
activate an alarm condition. If the system is programmed accordingly, it will
cause a reporting code to be sent to the central monitoring station.
Bypass To deactivate zone. When the panel is ARMED, violation of a bypassed zone
will be ignored.
Chime A short beep sound from the keypad to indicate a zone is violated.
Day Arm Instant arming that allows for certain preprogrammed, DAY STAY zones to be
violated while the system is armed. In this mode, an ENTRY delay time will be
given to the user to disarm using the keypad after entering the armed
premises.
Day Stay Zone Zones that are bypassed automatically when the system is DAY ARMED.
Disarm To deactivate the system. FIRE, PANIC and MEDICAL remain active while
the system is disarmed.
Duress Code An ambush code which will disarm the system and simultaneously send a
silent distress signal to the central monitoring station.
Entry/Exit Zone A zone with programmable delay time will allow user to exit the premises after
arming the system and disarm by using the keypad after entering the armed
premises. This zone is generally the last exit point and the first entry point of
the building, i.e. the front door of a house.
Follower Zone A zone that may be temporary violated during exit delay period or after the
first violation of an ENTRY/EXIT zone. This allows the user access to disarm
the system. A FOLLOWER zone will behave as an instant zone if it is violated
prior to the violation of an ENTRY/EXIT zone.
Force Arm Arming with exit delay that allows for certain violated zones to be bypassed
temporary. When the violated zones resume, these zones will be protected.
There is an ENTRY delay time in this arming mode.
Home Optional system expander module that allows you to control different light and
Automation appliances from any keypad, remote telephone, cellular phone. It can also be
(HA) programmed to turn on/off light at certain time daily or during alarm condition.
Instant Zone When the system is armed, any violation of an instant zone will immediately
cause an alarm condition to be registered.
Master Code Master code is a 4-digit personal identification number that allows you to
enter certain programming mode, arm or disarm the system and remotely
control the system via telephone line.
Night Arm Instant arming that allows for certain preprogrammed, NIGHT STAY zones to
be violated while the system is armed. In this mode, there is no ENTRY delay
time for the user.
Night Stay Zone Zones that are bypassed automatically when the system is NIGHT ARMED.
Partitioning A partitioned system is a single physical security system that provides
independent areas of protection intended for use by independent users.
Remote Control Arming with a momentary or latch remote control module. In this mode, it
Arm allows certain violated zones to be bypassed temporary. When the violated
zones resume, the zone will be protected. There is an ENTRY and EXIT
delay time in this arming mode.
User Code User code is a 4-digit personal identification number that allows you to arm or
disarm the system.
Zone A specific area of your premises guarded by sensors, which detect violations
of that area.

3
Version 1.2
V16 Plus USER MANUAL

UNDERSTAND YOUR KEYPAD INDICATORS (LED)

POWER INDICATOR PARTITION 1 ARM PARTITION 2 ARM MEMORY ZONE INDICATORS


(GREEN) INDICATOR (Red) INDICATOR (Red) INDICATOR (Red)
The indicator is The indicator is The indicator is (Orange) Indicate the status of
illuminated when AC illuminated when illuminated when The indicator will slow the zones
power is present partition 1 is armed partition 2 is armed flash when the alarm
is triggered

KEYLOCK
2 DAY ARM INDICATOR
This key will activate (Orange)
the DAY ARM mode The indicator is
when hold down for 2 illuminated when the
seconds keypad is locked

1 AWAY ARM SERVICE


This key will activate INDICATOR
the AWAY ARM mode (Orange)
when hold down for 2 The indicator is
seconds illuminated when the
system is in trouble
condition

5 TURN ON/OFF HA
POINT 3 NIGHT ARM
This key will TURN This key will activate
ON/OFF HA point the NIGHT ARM
when hold down for 2 mode when hold
seconds down for 2 seconds

4 FORCE ARM
This key will activate FIRE ALARM
the FORCE ARM This key will activate
mode when hold the FIRE ALARM
down for 2 seconds when hold down for 2
seconds

7 VIEW TROUBLE
This key will activate
the VIEW TROUBLE PANIC ALARM
mode when hold This key will activate
down for 2 seconds the PANIC ALARM
when hold down for 2
seconds

STAR CANCEL
This key will cancel
any unintended 6 BYPASS ZONE
entries This key will activate
the BYPASS mode
when hold down for 2
seconds

8 VIEW ALARM
MEMORY
This key will activate
the VIEW ALARM
MEMORY mode MEDICAL ALARM
when hold down for 2 This key will activate
seconds the MEDICAL ALARM
when hold down for 2
seconds

0 HOLIDAY MODE
This key will activate
HOLIDAY mode when
hold down for 2
seconds SYSTEM SUMMARY HASH ENTER 9 CHIME MODE MODE
TABLE This key will confirm This key will activate This key will start the
This sticker will show all commands entered the CHIME mode programming or test
all zones location and to the system when hold down for 2 mode command
all 1 touch seconds

4
Version 1.2
V16 Plus USER MANUAL

UNDERSTAND YOUR KEYPAD INDICATORS (LCD)

PARTITION 1 ARMED PARTITION 2 ARMED SERVICE INDICATOR MEMORY INDICATOR MUTE KEYPAD
ICON ICON SOUND
The icon is displayed The icon will be blinking
The armed icon is The armed icon is when the system is in when the alarm is The icon will be
displayed when partition displayed when partition trouble condition triggered displayed when the
1 is armed 2 is armed keypad is muted.

POWER INDICATOR KEYLOCK


INDICATOR
The icon is displayed
when AC power is The icon is displayed
present when the keypad is
locked

CLOCK
2 DAY ARM
Display Clock
This key will activate
the DAY ARM mode
when hold down for 2
seconds

ZONE INDICATORS
Indicate the status of
the zones

1 AWAY ARM
This key will activate
the AWAY ARM mode 3 NIGHT ARM
when hold down for 2 This key will activate
seconds the NIGHT ARM mode
when hold down for 2
seconds

5 TURN ON/OFF HA
POINT
This key will TURN Fire emergency
ON/OFF HA point This key will activate
when hold down for 2 The fire emergency
Warning
seconds

Scroll Up
4 FORCE ARM This key will scroll up
This key will activate for manual &
the FORCE ARM Instructions
mode when hold
down for 2 seconds
Scroll Down
This key will scroll
Down for manual &
7 VIEW TROUBLE Instructions
This key will activate
the VIEW TROUBLE
mode when hold 6 BYPASS ZONE
down for 2 seconds This key will activate
the BYPASS mode
when hold down for 2
seconds
STAR CANCEL
This key will cancel
any unintended
entries
Or Exit to the main
menu

8 VIEW ALARM 0 HOLIDAY MODE HASH ENTER 9 CHIME MODE MODE


MEMORY This key will activate This key will confirm This key will activate This key will start
This key will activate HOLIDAY mode when all commands entered the CHIME mode the programming
the VIEW ALARM hold down for 2 to the system when hold down for 2 or test mode
MEMORY mode seconds seconds command
when hold down for 2
seconds

5
Version 1.2
V16 Plus USER MANUAL

SUMMARY OF OPERATION

Intelligent Disarm [4-digit User Code] + [#]

Intelligent Arming [4-digit User Code] + [#]

Away Arm Hold down [1] for 2 seconds

Day Arm Hold down [2] for 2 seconds

Night Arm Hold down [3] for 2 seconds

Force Arm Hold down [4] for 2 seconds


Turn On/Off Home
Hold down [5] for 2 seconds + [HA point number 1 to 16] + [#]
Automation Point
Bypass Security Zone Hold down [6] for 2 seconds + [Zone number 1 to 16] + [#]

View System Trouble Hold down [7] for 2 seconds

View Alarm Memory Hold down [8] for 2 seconds

Program Chime Zone Hold down [9] for 2 seconds + [Zone number 1 to 16] + [#]

Holiday Mode Arming Hold down [0] for 2 seconds

Activate Fire Alarm Hold down [F] for 2 seconds

LED: Hold down [P] for 2 seconds


Activate Panic Alarm
LCD: Press [MODE] + [8] + [#]

LED: Hold down [M] for 2 seconds


Activate Medical Alarm
LCD: Press [MODE] + [9] + [#]

Turn On/Off Keypad LED: Hold down [MODE] for 2 seconds


Buzzer LCD: Press [MODE] + [6] + [#]

View Event Log LCD: Press [MODE] + [MODE] + [#]

Remark:
To enter zone number more than 9, press button [F] to represent the ten’s digit.
e.g. To enter zone number 15, press [F] + [5].

6
Version 1.2
V16 Plus USER MANUAL

SUMMARY OF OPERATION

PARTITION SYSTEM ENABLED

Intelligent Disarm [4-digit User Code] + [#] + [Partition 1] or [Partition 2]

Intelligent Arming [4-digit User Code] + [#] + [Partition 1] or [Partition 2]

Away Arm Hold down [1] for 2 seconds + [Partition 1] or [Partition 2]

Day Arm Hold down [2] for 2 seconds + [Partition 1] or [Partition 2]

Night Arm Hold down [3] for 2 seconds + [Partition 1] or [Partition 2]

Force Arm Hold down [4] for 2 seconds + [Partition 1] or [Partition 2]

Holiday Mode Arming Hold down [0] for 2 seconds + [Partition 1] or [Partition 2]

TESTING THE SYSTEM

LED: [MODE] + [1] + [#]


Sensor Walk Test
LCD: [MODE] + [1] + [#] OR MENU  System Test  Walk Test

LED: [MODE] + [2] + [#]


CMS Reporting Test
LCD: [MODE] + [2] + [#] OR MENU  System Test  CMS Test

LED: [MODE] + [3] + [#]


Siren Test
LCD: [MODE] + [3] + [#] OR MENU  System Test  Siren Test

LED: [MODE] + [4] + [#]


Strobe Light Test
LCD: [MODE] + [4] + [#] OR MENU  System Test  Strobe Test

LED: [MODE] + [5] + [#]


Battery Test
LCD: [MODE] + [5] + [#] OR MENU  System Test  Battery Test

7
Version 1.2
V16 Plus USER MANUAL

TELEPHONY CONTROL DIAGRAM


Call In to System:

Dial Wait for [Master System


Phone Answer Code] + welcome 1 System Voice Report on:
Number [#] note and
voice - Alarm triggered zone
menu
- System Arm / Disarm
- Zone Open / Close / Bypassed
- Siren On / Off / Fail
- AC power status
- Home Automation On / Off

2 Force Arm / Disarm system


System Call Out:

Answer Slow [Master System


Call beeps Code] + voice
[#] report
and voice 3 On/Off Siren
menu

4 On/Off 01 to 16
Home (HA
Automation Points)
Point

00 (ON /
OFF All
HA
Points)

5 Bypass/ 01 to 16
Unbypass (Zone
Zone number)

00 Bypass/
Unbypass
All Zones

0 On-site Listen-in Control

# (Terminate Telephone
Reporting Immediately)

Remark:

The system will automatically cut off telephone line if the user does not key in any number for more
than 60 seconds or key in wrong master code more than 3 times.

8
Version 1.2
V16 Plus USER MANUAL

USER PROGRAMMING SUMMARY DIAGRAM (LED)


The indicator is illuminated when the keypad is locked

ER PROGRAMMING SUMMARY TABLE

PROGRAM CODES
ENTER USER MASTER CODE
PROGRAMMING Press [01] + [New Code] + [Re-enter New Code] + [#]
MODE

[ ] + [MODE] +
USER CODE
[Master Code] + [#]
Press [02 - 14] + [New Code] + [Re-enter New Code] + [#]
Correct code or
step – 2 beeps
DOOR ACCESS CODE
Wrong code or
step – 1 long beep Press [15] + [New Code] + [Re-enter New Code] + [#]

DURESS CODE
Press [16] + [New Code] + [Re-enter New Code] + [#]

PROGRAM SYSTEM CLOCK


SYSTEM TIME CLOCK
Press [17] + [Timer in 24-hour format] + [#]

PROGRAM SECURITY TIMERS


SECURITY AUTO ARM/DISARM TIMERS
Press [18 - 21] + [Timer in 24-hour format] + [#]

PROGRAM HOME AUTOMATION TIMERS


HOME AUTOMATION ON/OFF TIMERS
Press [22- 29] + [Timer in 24-hour format] + [#]

PROGRAM REPORTING TELEPHONE NUMBER


REPORTING TELEPHONE NUMBER
Press [30 - 33] + [Reporting telephone number] + [#]

EXIT USER PROGRAMMING MODE


EXIT USER PROGRAMMING MODE
Press [MODE] + [#]

9
Version 1.2
V16 Plus USER MANUAL

USER PROGRAMMING SUMMARY TABLE (LED)

Enter User Programming Mode [] + [MODE] + [4-digit Master Code] + [#]

Exit User Programming Mode [MODE] + [#]

Program New or Change Existing

[01] + [New Master Code] + [Re-enter New Master Code] +


Master Code 01
[#]

Program New or Change Existing

User Code 2 [02] + [New User Code] + [Re-enter New User Code] + [#]

User Code 3 [03] + [New User Code] + [Re-enter New User Code] + [#]

User Code 4 [04] + [New User Code] + [Re-enter New User Code] + [#]

User Code 5 [05] + [New User Code] + [Re-enter New User Code] + [#]

User Code 6 [06] + [New User Code] + [Re-enter New User Code] + [#]

User Code 7 [07] + [New User Code] + [Re-enter New User Code] + [#]

User Code 8 [08] + [New User Code] + [Re-enter New User Code] + [#]

User Code 9 [09] + [New User Code] + [Re-enter New User Code] + [#]

User Code 10 [10] + [New User Code] + [Re-enter New User Code] + [#]

User Code 11 [11] + [New User Code] + [Re-enter New User Code] + [#]

User Code 12 [12] + [New User Code] + [Re-enter New User Code] + [#]

User Code 13 [13] + [New User Code] + [Re-enter New User Code] + [#]

User Code 14 [14] + [New User Code] + [Re-enter New User Code] + [#]

Program New or Change Existing

Door Access Code [15] +[New User Code] + [Re-enter New User Code] + [#]

Program New or Change Existing

Duress Code [16] + [New User Code] + [Re-enter New User Code] + [#]
Remark:
1. All programmed codes must be unique from each other. Duplicate code will be rejected
during user programming mode.

2. Door Access Code is not a security code. This code cannot ARM/DISARM the security
system. Door Access Code is a special code programmed to control your door access
system.

10
Version 1.2
V16 Plus USER MANUAL

USER PROGRAMMING SUMMARY TABLE (LED)

3. Master code, User Code 2,User Code 3 and User Code 4 are telephone remote
access codes. These codes can ARM/DISARM the security system via local keypad or
via telephone remote access.

Program System Timer

System Clock [17] + [Current Time in 24-hour Format] + [#]

Program Security Timers

Partition 1 Auto Arm Timer [18] + [Partition 1 Security Auto ARM Timer] + [#]

Partition 1 Auto Disarm Timer [19] + [Partition 1 Security Auto DISARM Timer] + [#]

Partition 2 Auto Arm Timer [20] + [Partition 2 Security Auto ARM Timer] + [#]

Partition 2 Auto Disarm Timer [21] + [Partition 2 Security Auto DISARM Timer] + [#]

Program Home Automation Timers

Home Automation Auto ON


[22] + [Home Automation Auto ON Timer 1] + [#]
Timer 1
Home Automation Auto OFF
[23] + [Home Automation Auto OFF Timer 1] + [#]
Timer 1
Home Automation Auto ON
[24] + [Home Automation Auto ON Timer 2] + [#]
Timer 2
Home Automation Auto OFF
[25] + [Home Automation Auto OFF Timer 2] + [#]
Timer 2
Home Automation Auto ON
[26] + [Home Automation Auto ON Timer 3] + [#]
Timer 3
Home Automation Auto OFF
[27] + [Home Automation Auto OFF Timer 3] + [#]
Timer 3
Home Automation Auto ON
[28] + [Home Automation Auto ON Timer 4] + [#]
Timer 4
Home Automation Auto OFF
[29] + [Home Automation Auto OFF Timer 4] + [#]
Timer 4

Remark: All programmed timer must be in 24-hour format e.g. 7 am = 07 00, 8 pm = 20 00.

Program Reporting Telephone Number

Telephone Number 1 [30] + [Reporting Telephone Number 1] + [#]

Telephone Number 2 [31] + [Reporting Telephone Number 2] + [#]

Telephone Number 3 [32] + [Reporting Telephone Number 3] + [#]

Telephone Number 4 [33] + [Reporting Telephone Number 4] + [#]

Remark: Button “P” on the keypad is representing a “PAUSE” key of 5 seconds duration,
Button “M” on the keypad is representing a “” key of telephone system.

11
Version 1.2
V16 Plus USER MANUAL

USER PROGRAMMING SUMMARY DIAGRAM (LCD)


The indicator is illuminated when the keypad is locked

ER PROGRAMMING SUMMARY TABLE


Menu Zone Info Zone 1 – 16 vocabulary setting

HA Point Info HA Point 1 – 16 vocabulary setting

Mute Keypad

User Mode Enter Code + [#] Passwords PROGRAM CODE


Master Code 01
User Code 02 - 15
Duress Code

Clock PROGRAM CLOCK


Clock

Timers PROGRAM TIMER


Arm P1 Timer
Disarm P1 Timer
Arm P2 Timer
Disarm P2 Timer
ON HA Timer 1
OFF HA Timer 1
ON HA Timer 2
OFF HA Timer 2
ON HA Timer 3
OFF HA Timer 3
ON HA Timer 4
OFF HA Timer 4

Tel Numbers PROGRAM TEL NO


User Tel No 1
User Tel No 2
User Tel No 3
User Tel No 4

Date PROGRAM DATE


Date

Schedule PROGRAM
SCHEDULE
Arm P1 Timer
Disarm P1 Timer
Arm P2 Timer
Disarm P2 Timer
ON HA Timer 1
OFF HA Timer 1
ON HA Timer 2
Installer Mode Enter Code + [#] OFF HA Timer 2
ON HA Timer 3
OFF HA Timer 3
ON HA Timer 4
System Tests Walk Test OFF HA Timer 4
CMS Test
Siren Test
Strobe Test
Battery Test

Software Info

12
Version 1.2
V16 Plus USER MANUAL

USER PROGRAMMING SUMMARY TABLE (LCD)

Enter User Programming Mode : [] + [MODE] + [4-digit Master Code] + [#] / Enter from LCD Menu

Exit User Programming Mode : [] / Exit from LCD Menu

Program New or Change Existing

Password Master Code 01 Key in [New User Code] + [#] [Re-confirm New User Code] + [#]

User Code 02 Key in [New User Code] + [#] [Re-confirm New User Code] + [#]

User Code 03 Key in [New User Code] + [#] [Re-confirm New User Code] + [#]

User Code 04 Key in [New User Code] + [#] [Re-confirm New User Code] + [#]

User Code 05 Key in [New User Code] + [#] [Re-confirm New User Code] + [#]

User Code 06 Key in [New User Code] + [#] [Re-confirm New User Code] + [#]

User Code 07 Key in [New User Code] + [#] [Re-confirm New User Code] + [#]

User Code 08 Key in [New User Code] + [#] [Re-confirm New User Code] + [#]

User Code 09 Key in [New User Code] + [#] [Re-confirm New User Code] + [#]

User Code 10 Key in [New User Code] + [#] [Re-confirm New User Code] + [#]

User Code 11 Key in [New User Code] + [#] [Re-confirm New User Code] + [#]

User Code 12 Key in [New User Code] + [#] [Re-confirm New User Code] + [#]

User Code 13 Key in [New User Code] + [#] [Re-confirm New User Code] + [#]

User Code 14 Key in [New User Code] + [#] [Re-confirm New User Code] + [#]

User Code 15 Key in [New User Code] + [#] [Re-confirm New User Code] + [#]
(Door Access Code)

Duress Code Key in [New User Code] + [#] [Re-confirm New User Code] + [#]
Remark:
1. User code 15 (Door Access Code) is not a security code. This code cannot ARM/DISARM the
security system. User code 15 is a special code programmed to control your access system.
2. Master code, User Code 2,User Code 3 and User Code 4 are telephone remote
access codes. These codes can ARM/DISARM the security system via local keypad or
via telephone remote access.

Program System Timer

Clock Real Time Clock Key in time [0000 to 2359] + [#] [F # to erase the previous setting]

13
Version 1.2
V16 Plus USER MANUAL

USER PROGRAMMING SUMMARY TABLE (LCD)

Program Security Timers

Timers Arm P1 Timer Key in time [0000 to 2359] + [#] [F# to erase the previous setting]

Disarm P1 Timer Key in time [0000 to 2359] + [#] [F# to erase the previous setting]

Arm P2 Timer Key in time [0000 to 2359] + [#] [F# to erase the previous setting]

Disarm P2 Timer Key in time [0000 to 2359] + [#] [F# to erase the previous setting]

Program Home Automation Timers

Timers ON HA Timer 1 Key in time [0000 to 2359] + [#] [F# to erase the previous setting]

OFF HA Timer 1 Key in time [0000 to 2359] + [#] [F# to erase the previous setting]

ON HA Timer 2 Key in time [0000 to 2359] + [#] [F# to erase the previous setting]

OFF HA Timer 2 Key in time [0000 to 2359] + [#] [F# to erase the previous setting]

ON HA Timer 3 Key in time [0000 to 2359] + [#] [F# to erase the previous setting]

OFF HA Timer 3 Key in time [0000 to 2359] + [#] [F# to erase the previous setting]

ON HA Timer 4 Key in time [0000 to 2359] + [#] [F# to erase the previous setting]

OFF HA Timer 4 Key in time [0000 to 2359] + [#] [F# to erase the previous setting]

Remark: All programmed timer must be in 24-hour format e.g. 7 am = 07 00, 8 pm = 20 00.

Program Reporting Telephone Numbers

Tel No’s User Tel No 1 Key in [14 digit Tel No.] + [#] [F to erase the previous setting]

User Tel No 2 Key in [14 digit Tel No.] + [#] [F to erase the previous setting]

User Tel No 3 Key in [14 digit Tel No.] + [#] [F to erase the previous setting]

User Tel No 4 Key in [14 digit Tel No.] + [#] [F to erase the previous setting]

Remark: Button “▲” on the keypad is representing a “PAUSE” key of 5 seconds duration,
Button “▼” on the keypad is representing a “” key of telephone system.

Program System Date

Date Current Date [DD/MM/YY] + [#] [F # to erase the previous setting]

14
Version 1.2
V16 Plus USER MANUAL

USER PROGRAMMING SUMMARY TABLE (LCD)

Program Security and Home Automation Timers Schedule

Schedule Arm P1 Timer Press 1 for Monday 1 2 3 4 5 6 7

Disarm P1 Timer Press 2 for Tuesday 1 2 3 4 5 6 7

Arm P2 Timer Press 3 for Wednesday 1 2 3 4 5 6 7

Disarm P2 Timer Press 4 for Thursday 1 2 3 4 5 6 7

ON HA Timer 1 Press 5 for Friday 1 2 3 4 5 6 7

OFF HA Timer 1 Press 6 for Saturday 1 2 3 4 5 6 7

ON HA Timer 2 Press 7 for Sunday 1 2 3 4 5 6 7

OFF HA Timer 2 1 2 3 4 5 6 7

ON HA Timer 3 1 2 3 4 5 6 7

OFF HA Timer 3 1 2 3 4 5 6 7

ON HA Timer 4 1 2 3 4 5 6 7

OFF HA Timer 4 1 2 3 4 5 6 7

15
Version 1.2
V16 Plus USER MANUAL

ARMING THE SYSTEM

There are various options for arming the system


a. Partition Arming
b. Away Arming
c. Day Arming
d. Night Arming
e. Force Arming
f. Holiday Arming
g. Remote Control Arming
h. Timer Auto Arming
i. Telephone Remote Arming

For information on how to ARM Partition system, please refer to PARTITIONING THE SYSTEM at
page 28.

AWAY ARMING

[] + [USER CODE] + [#]


(Leave via ENTRY/EXIT Zone)

1. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
2. Press the [] key to cancel any unintended entries.
3. Enter a valid 4-digit [USER CODE]. If you enter any mistakes, press [] key and re-enter
the code followed by [#] key to confirm you command.

4. P1 indicator will illuminate.


icon will be displayed

An EXIT delay countdown timer will be


shown at the top right temporarily replace
the clock.

5. The keypad audible indicator will sound on and off for the duration of the EXIT delay.
6. Any bypassed zones will be shown by the flashing zone indicators.
7. Leave the premises only via the EXIT/ENTRY zone.

8. During AWAY arming, the telephone line will be supervised hourly. If the telephone line
is disconnected, a new trouble condition will be registered (please refer to View System
Trouble).
9. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.
10. It is also possible to AWAY arm by simply enter and hold down [1] key for 2 seconds.
[1]
(Press and hold down for 2 seconds)

16
Version 1.2
V16 Plus USER MANUAL

DAY ARMING

[2]
(Press and hold down for 2 seconds)
1. This arming mode is ideal for DAY time arming with user still remains in the protected
premises.

2. In this mode, the system will be armed instantly with certain preprogrammed, DAY
STAY zones bypassed automatically.
3. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
4. DO NOT open the ENTRY/EXIT zone.
5. Enter and hold down [2] key for 2 seconds.
6. P1 indicator will illuminate.
icon will be displayed

7. The keypad audible indicator will sound 2 beeps to confirm the arming.
8. Any DAY STAY zones will be automatically bypassed (shown by flashing zone
indicators).
9. User will be given an ENTRY delay time to DISARM the system when enter the
protected premises via ENTRY/EXIT zone.

NIGHT ARMING

[3]
(Press and hold down for 2 seconds)

1. This arming mode is ideal for NIGHT time arming with user still remains in the protected
premises.
2. In this mode, the system will be armed instantly with certain preprogrammed, NIGHT
STAY zones bypassed automatically.
3. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
4. DO NOT open the ENTRY/EXIT zone.
5. Enter and hold down [3] key for 2 seconds.
6. P1 indicator will illuminate.
icon will be displayed

7. The keypad audible indicator will sound 2 beeps to confirm the arming.
8. Any NIGHT STAY zones will be automatically bypassed (shown by flashing zone
indicators).
9. There is no ENTRY delay in this arming mode. Any violation on the active zones will
trigger the system instantly.

17
Version 1.2
V16 Plus USER MANUAL

FORCE ARMING

[4]
(Press and hold down for 2 seconds)

1. In this mode, the system will be armed with EXIT delay time which allows certain
violated zones to be bypassed temporary. When the violated zones resume, the zone
will be protected again.
2. Enter and hold down [4] key for 2 seconds.
3. P1 indicator will illuminate.
icon will be displayed

An EXIT delay countdown timer will be


shown at the top right temporarily replace
the clock.
4. The keypad audible indicator will sound on and off for the duration of the EXIT delay.
5. Any bypassed zones will be shown by the flashing zone indicators
6. User will be given an ENTRY delay time to DISARM the system when enter the
protected premises via ENTRY/EXIT zone.

HOLIDAY ARMING

[0]
(Press and hold down for 2 seconds)

1. This arming mode is ideal for long away occasion (holiday).


2. In this mode, the system will be AWAY armed. Home Automation points will be random
ON/OFF every hour to simulate occupancy from 7pm to 1am.
3. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
4. Enter and hold down [0] key for 2 seconds.
5. P1 indicator will illuminate.
icon will be displayed

An EXIT delay countdown timer will be


shown at the top right temporarily replace
the clock.
6. The keypad audible indicator will sound on and off for the duration of the EXIT delay.
7. Any bypassed zones will be shown by the flashing zone indicators.
8. Leave the premises only via the EXIT/ENTRY zone.
9. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.

18
Version 1.2
V16 Plus USER MANUAL

10. After disarming, Home Automation random ON/OFF function will be deactivated and the
system will resume to normal Home Automation ON/OFF timers setting.

REMOTE CONTROL ARMING

1. This arming mode is ideal for remote control unit or key-switch arming.
2. The system will arm in AWAY arming mode.
3. The system will be armed with EXIT delay time which allows certain violated zones to be
bypassed temporary. When the violated zones resume, the zone will be protected again.
4. Press the remote control button or twist and release the key-switch.
5. The system will be armed instantly. Leave the premises via ENTRY/EXIT zone.
6. P1 indicator will illuminate.
icon will be displayed

An EXIT delay countdown timer will be


shown at the top right temporarily replace
the clock.
7. The keypad audible indicator will sound 2 beeps to confirm the arming.
8. If programmed to do so, the siren will sound briefly for this remote control arming (please
refer to Installer Programming Section – System Option Setting).
9. User will be given an ENTRY delay time to DISARM the system when enter the
protected premises via ENTRY/EXIT zone.

TIMER AUTO ARMING

1. Your system can be programmed to automatically ARM itself according to a programmed


schedule.
2. This arming mode will automatically turn to FORCE ARM mode when the system timer
reaches the preset AUTO ARM time.
3. Please refer to User Programming Section – Program Auto ARM Timer.

TELEPHONE REMOTE ARMING

1. Your system can be remotely ARM from outside the house through any normal DTMF
telephone or GSM hand phone.
2. This arming mode will automatically turn to FORCE ARM mode when the user enter a correct
Master Code through Telephone or hand phone.
3. Please refer to Telephony Control Diagram at page 8.

19
Version 1.2
V16 Plus USER MANUAL

DISARMING THE SYSTEM

There are various options for disarming the system:

a. Partition Disarming
b. Keypad Disarming
c. Remote Control Disarming
d. Timer Auto Disarming
e. Telephone Remote Disarm

For information on how to DISARM Partition system, please refer to PARTITION DISARMING at
page 35.

KEYPAD DISARMING

[USER CODE] + [#]

1. To disarm the system, enter a valid 4-digit [USER CODE] followed by [#] key before
expiry of the entry delay time.
2. Enter the premises through a designated ENTRY/EXIT zone; entering via other zones
will trigger an alarm instantly.
3. The ENTRY delay begins once the ENTRY zone is violated.
4. The keypad audible indicator will sound for the duration of the ENTRY delay to indicate
that a valid user code is required.
5. If the P1 indicator remains illuminated, an
error has been made while entering the If the icon remains displayed, an
user code. Press [] key and re-enter the error has been made while entering the
user code. user code. Press [] key and re-enter the
user code.

An ENTRY delay countdown timer will be


shown at the top right temporarily replace
the clock.

6. Once the system is disarmed, the P1


indicator will extinguish and the keypad Once the system is disarmed, the
audible indicator will stop. icon will extinguish and the keypad
audible indicator will stop.

7. If the MEMORY indicator is flashing upon


entry there has been an intrusion. Call for If the icon is flashing upon entry
assistance. The intruder may still be inside. there has been an intrusion. Call for
assistance. The intruder may still be
inside.

20
Version 1.2
V16 Plus USER MANUAL

8. If no valid user code has been entered by the end of the ENTRY delay period, an
ALARM condition will be registered and stored into the system MEMORY.
9. If programmed to do so, the keypad will be locked and non-responsive for a
preprogrammed period for certain number of incorrect user codes, which are entered
consecutively more than the keypad lock counter.
10. If the ENTRY delay is too short, have your installer to change the ENTRY delay period.

REMOTE CONTROL DISARMING

1. To instantly disarm the system, press the remote control button or twist and release the
key-switch.
2. The P1 indicator will extinguish and the
keypad audible indicator will sound 2 beeps The icon will extinguish and the
to confirm the disarming. keypad audible indicator will sound 2
beeps to confirm the disarming.

3. If programmed to do so, the siren will sound briefly for this remote control disarming.
(Please refer to Installer Programming Section – System Option Setting).

TIMER AUTO DISARMING

1. Your system can be programmed to automatically DISARM itself according to a programmed


schedule.
2. Please refer to User Programming Section – Program Auto Disarm Timer.

TELEPHONE REMOTE DISARMING

1. Your system can be remotely DISARM from outside the house through any normal DTMF
telephone or GSM hand phone.
2. This disarming mode will automatically turn off the security system when the user enters a
correct Master Code through Telephone or hand phone.
3. Please refer to Telephony Control Diagram at page 8.

21
Version 1.2
V16 Plus USER MANUAL

TURN ON/OFF HOME AUTOMATION POINT

[5] + [HA POINT NUMBERS] + [#]


(Press and hold down for 2 seconds) (1 to 16)

1. Enter and hold down [5] key for 2 seconds.


2. The POWER and P1 indicators will slow The screen will show “HA Info” and
flash and keypad audible indicator will keypad audible indicator will sound 2
sound 2 beeps. beeps.

Zone indicators 1 to 16 will turn ON if the Zone numbers 1 to 16 will be displayed if


respective HA points are ON. the respective HA points are ON.
Zone numbers 1 to 16 will not be
Zone indicators 1 to 16 will turn OFF if the
respective HA points are OFF displayed if the respective HA points are
OFF.
3. Enter the HA point numbers followed by [#] key. Keypad audible indicator will sound 2
beeps to confirm the command and the system will be back to normal mode.
4. To turn On/Off all Home Automation (HA) points at once, enter [0] key followed by [#].

5. Keypad audible indicator will sound 2 beeps to confirm the command and the system will
be back to normal mode.

e.g. To turn ON/OFF HA point 3 and 4:


Press and hold down [5] for 2 seconds + [3] + [4] + [#]
Keypad audible indicator will sound 2 beeps to confirm the command. HA point 3 and 4 will
turn ON.

BYPASS ZONE

[6] + [ZONE NUMBERS] + [#]


(Press and hold down for 2 seconds) (1 to 16)

1. Enter and hold down [6] key for 2 seconds.


2. The P1 and KEYLOCK indicators will slow The screen will show “Bypass Info” and
flash and keypad audible indicator will keypad audible indicator will sound 2
sound 2 beeps. beeps.

3. Press the zone number that needs to be bypassed, e.g. press [2] if you wish to bypass
zone 2.

22
Version 1.2
V16 Plus USER MANUAL

4. To enter zone number more than 9, press button [F] to represent the ten’s digit.
5. E.g. To enter zone number 12, press [F] + [2], zone number 16 press [F] + [6].

6. Repeat step 3 to bypass other zones.


7. Press [#] key to exit the bypass mode and keypad audible indicator will sound 2 beeps
to confirm the command.
8. To bypass all zones at once, enter [0] key followed by [#].
9. Keypad audible indicator will sound 2 beeps to confirm the command and the system will
be back to normal mode.
10. The relevant ZONE indicator will slow flash to indicate that the zone is bypassed now.

11. Zones cannot be bypassed once the system is armed.


12. All bypassed zones will be automatically un-bypassed each time the system is disarmed
and must be reapplied before the next arming.

UN-BYPASS ZONE

[6] + [ZONE NUMBERS] + [#]


(Press and hold down for 2 seconds) (1 to 16)

1. Enter and hold down [6] key for 2 seconds.


2. The P1 and KEYLOCK indicators will slow The screen will show the un-Bypass
flash and keypad audible indicator will Zones and keypad audible indicator will
sound 2 beeps. sound 2 beeps.

3. Press the zone number corresponding to the current bypassed zone e.g. press [2] if you
wish to un-bypass zone 2.

4. To enter zone number more than 9, press button [F] to represent the ten’s digit.
5. E.g. To enter zone number 12, press [F] + [2], zone number 16 press [F] + [6].

6. Repeat step 3 to un-bypass other zones if any.


7. Press [#] key to exit the un-bypass mode and keypad audible indicator will sound 2
beeps to confirm the command.
8. To un-bypass all zones at once, enter [0] key followed by [#].

23
Version 1.2
V16 Plus USER MANUAL

9. Keypad audible indicator will sound 2 beeps to confirm the command and the system will
be back to normal mode.
10. The relevant ZONE indicator will extinguish to indicate that the zone is now active.

VIEW SYSTEM TROUBLE

[7]
(Press and hold down for 2 seconds)

1. The system will monitor a number of possible trouble conditions. If one of these
conditions occurs, the following events will occur.
2. The SERVICE indicator turns ON.
The icon displayed.

The SERVICE indicator will illuminate until


the trouble is restored. The icon will display until the trouble
is restored.
3. Enter and hold down [7] key for 2 seconds.
The SERVICE and KEYLOCK indicators The screen will show the service indicator
will slow flash and keypad audible indicator and keypad audible indicator will sound 2
will sound 2 beeps. beeps.
One or more ZONE indicators will turn ON The trouble occurred will be displayed.
to indicate the troubles occur e.g zone Press the [▼] key to check on all the
number 2 turning ON indicate Real Time troubles that need to be serviced.
Clock Loss (refer table below).

4. Press [#] key to exit and keypad audible indicator will sound 2 beeps.

ZONE 1 indicator AC Loss


ZONE 2 indicator Real Time Clock Loss (Program System Timer - refer to page 40)
ZONE 3 indicator Siren Fail
ZONE 4 indicator Battery Low Voltage
ZONE 5 indicator Telephone Line/GSM CMS Reporting Fail
ZONE 6 indicator Telephone Line/GSM Personal Reporting Fail
ZONE 7 indicator Telephone Line Connection Fail

Remark: Zone 1, 2, 3 and 4 indicators will only be extinguished after the troubles are restored.
Zone 5, 6 and 7 indicators will be extinguished when they are viewed once.

24
Version 1.2
V16 Plus USER MANUAL

VIEW ALARM MEMORY

[8]
(Press and hold down for 2 seconds)

1. The system alarm memory will store the most recent alarm condition. An alarm condition
will cause the following events.
2. The MEMORY indicator slow flash.
The icon flash.

The MEMORY indicator will extinguish


once the user enters VIEW ALARM The icon will extinguish once the
MEMORY mode. user enters VIEW ALARM MEMORY
mode.
3. Enter and hold down [8] key for 2 seconds.

The MEMORY indicator will turn ON and The screen will show “Alarm Memory”
keypad audible indicator will sound 2 and keypad audible indicator will sound 2
beeps. beeps.
One or more ZONE indicators will turn ON One or more ZONE numbers will be
to indicate the zones that cause the most displayed to indicate the zones that cause
recent alarm. the most recent alarm.

4. Press [#] key to exit and keypad audible indicator will sound 2 beeps.

CHIME MODE

The chime mode allows user to monitor nominated zones while the system is disarmed. The audible
indicator will sound briefly when the nominated zone is violated – the siren will NOT sound. If you wish
to know there is someone enters or exits the front door, the keypad will beep once when the door is
opened provided the zone is a chime zone.

[9] + [ZONE NUMBERS] + [#]


(Press and hold down for 2 seconds) (1 to 16)

1. Press and hold down [9] key for 2 seconds.


2. The POWER and KEYLOCK indicators will The screen will show “Chime Info” and
slow flash and keypad audible indicator will keypad audible indicator will sound 2
sound 2 beeps. beeps.

3. Press the key corresponding to the zone that you wish to be the chime zone.
4. To enter zone number more than 9, press button [F] to represent the ten’s digit.
5. E.g. To enter zone number 12, press [F] + [2], zone number 16 press [F] + [6].
6. Press [#] key to exit the chime mode and keypad audible indicator will sound 2 beeps to

25
Version 1.2
V16 Plus USER MANUAL

confirm the command.

e.g. To program zone 3 and zone 4 as CHIME zones:


Press and hold down [9] for 2 seconds + [3] + [4] + [#]
Keypad audible indicator will sound 2 beeps to confirm the command. Zone 3 and 4 are now
CHIME zones.

TO CANCEL CHIME ZONE:


Repeat the above steps and ensure that the zone indicator/display is extinguished.

EMERGENCY SITUATION
Indicate the status of the zones

OMEMORY INDICATOR (Orange)


FIRE MODE
The indicator will slow flash when the alarm is triggered

NSERVICE INDICATOR (Orange) [F]


(Press
The indicator is illuminated when the system is in trouble condition and hold down for 2 seconds)
SPOWER INDICATOR (GREEN)
1. This key will activate the FIRE ALARM condition when it is held down for 2 seconds.
The indicator is illuminated when AC power is present

ARMED INDICATOR (Red)


The indicator is illuminated when the system is armed

2. The FIRE ALARM condition can also be triggered by an installed smoke detector, which is set
as fire zone.
3. The siren will sound and the FIRE REPORTING CODE will be transmitted to the central
monitoring station.
4. To silence the siren, enter a 4-digit user code followed by [#] key.

PANIC MODE

1. The PANIC ALARM condition will be activated when:


2. Hold down [P] key for 2 seconds Press [MODE] followed by [8] and [#]

3. The PANIC ALARM condition can also be activated by any FIXED or REMOTE PANIC button
that has been installed.
4. If the panic button is set as silent zone, then the PANIC REPORTING CODE will be
transmitted to the central monitoring station without the siren sounding. Ensure that your
installer has enabled this function if it is required.
5. To silence the siren, enter a valid 4-digit user code followed by [#] key. If the siren is not
cancelled, it will stop automatically after the SIREN TIME OUT period.
6. Press this mode only in an emergency situation that requires response by emergency
personnel.

26
Version 1.2
V16 Plus USER MANUAL

MEDICAL MODE

1. The MEDICAL ALARM condition will be activated when:


2. Hold down [M] key for 2 seconds Press [MODE] followed by [9] and [#]

3. The keypad audible indicator will sound to indicate that a MEDICAL ALARM has been
initiated.
4. The siren will sound and the MEDICAL REPORTING CODE will be transmitted to the central
monitoring station.
5. To silence the siren, enter a 4-digit user code followed by [#] key.

DURESS CODE

1. This is a special 4-digit user code that is only used in the unique situation where an intruder
forces one to disarm the system “under duress”.
2. When the duress code is entered, the control panel will be disarmed. However, a DURESS
REPORTING CODE is transmitted to the central monitoring station to inform them that you
have been forced to disarm the control panel by an intruder.
3. It is advisable to choose a code that can be easily remembered by all family (or staff)
members.

27
Version 1.2
V16 Plus USER MANUAL

PARTITIONING THE SYSTEM

Depending on your needs, your installer can program your control panel to recognize and control 2
separate areas (Partition 1 and Partition 2) by activating the system’s partitioning feature. User codes
can also be programmed to ARM/DISARM one partition or both partitions simultaneously.

You can use partitioning in installations where shared systems are more practical, such as
office/warehouse buildings, or apartment/condominium complexes.

ARMING A PARTITIONED SYSTEM

Zones can be divided into two systems. Based on your requirements, the installer designates which
zones belong to Partition 1 and Partition 2, both partitions (dual area), or are not given any partition
assignment. A zone belonging to a 2 partitions is armed only when both Partition 1 and Partition 2 are
armed. However, this sharing zone will be disarmed if either Partition 1 or Partition 2 is disarmed.
The installer must program the required user code settings. These settings determine which user
codes can arm Partition 1, as well as which user codes can arm Partition 2. Codes can also be given
access to both partitions.

AWAY ARMING 2 PARTITIONS SIMULTANEOUSLY

If your user code has access to both partitions

[] + [USER CODE] + [#] + [1] + [2]


(Leave via ENTRY/EXIT Zone)

1. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
2. Press the [*] key to cancel any unintended entries.
3. Enter a valid 4-digit [USER CODE]. If you enter mistakes, press [*] key and re-enter the
code followed by [#] key to confirm your command.
4. If the key in user code is assigned to control 2 partitions:
Zone indicators 1 and 2 will flash. P1 and P2 options will be displayed.

5. Enter key [1] followed by key [2].

The P1 and P2 indicators will illuminate.


and icons will be displayed.

An EXIT delay countdown timer will be

28
Version 1.2
V16 Plus USER MANUAL

shown at the top right temporarily replace


the clock.
6. The keypad audible indicator will sound on and off for the duration of the EXIT delay.
7. Any bypassed zones will be shown by the flashing zone indicators.
8. Leave the premises only via the EXIT/ENTRY zone.
9. During AWAY arming, the telephone line will be supervised hourly. If the telephone line
is disconnected, a new trouble condition will be registered (please refer to View System
Trouble).
10. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.
11. It is also possible to AWAY arm by simply enter and hold down [1] key for 2 seconds.

[1] + [1 or 2]
(Press and hold down for 2 seconds)

12. Zone indicator [1] and [2] will flash. P1 and P2 options will be displayed.

Enter key [1] followed by key [2] to arm both partitions.

AWAY ARMING EITHER 1 PARTITION

If your user code has access to 2 partitions and you would like to arm Partition 1 only

[] + [USER CODE] + [#] + [1] + [#]


(Leave via ENTRY/EXIT Zone)

If your user code has access to 2 partitions and you would like to arm Partition 2 only

[] + [USER CODE] + [#] + [2] + [#]


(Leave via ENTRY/EXIT Zone)

1. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
2. Press the [*] key to cancel any unintended entries.
3. Enter a valid 4-digit [USER CODE]. If you enter mistakes, press [*] key and re-enter the
code followed by [#] key to confirm your command.
4. Zone indicator [1] and [2] will flash. P1 and P2 options will be displayed.

5. Enter the partition number that you wish to arm followed by [#] key.
The P1 indicator will illuminate if Partition 1
is armed. The icon will be displayed if Partition
1 is armed.

29
Version 1.2
V16 Plus USER MANUAL

An EXIT delay countdown timer will be


shown at the top right temporarily replace
the clock.
6. The P2 indicator will illuminate if Partition 2
is armed. The icon will be displayed if Partition
2 is armed.

An EXIT delay countdown timer will be


shown at the top right temporarily replace
the clock.
7. The keypad audible indicator will sound on and off for the duration of the EXIT delay.
Any bypassed zones will be shown by the flashing zone indicators.
8. Leave the premises only via the EXIT/ENTRY zone.
9. During AWAY arming, the telephone line will be supervised hourly. If the telephone line
is disconnected, a new trouble condition will be registered (please refer to View System
Trouble).
10. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.

If your user code has access to 1 partition only

[] + [USER CODE] + [#]


(Leave via ENTRY/EXIT Zone)

1. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.

2. Press the [*] key to cancel any unintended entries.

3. Enter a valid 4-digit [USER CODE]. If you enter mistakes, press [*] key and re-enter the
code followed by [#] key to confirm your command.
4. The P1 indicator will illuminate if the
entered user code is Partition 1 user code. The icon will be displayed if the
entered user code is Partition 1 user
code.

An EXIT delay countdown timer will be


shown at the top right temporarily replace
the clock.
5. The P2 indicator will illuminate if the
entered user code is Partition 2 user code. The icon will be displayed if the
entered user code is Partition 1 user
code.

An EXIT delay countdown timer will be


shown at the top right temporarily replace

30
Version 1.2
V16 Plus USER MANUAL

the clock.
6. The keypad audible indicator will sound on and off for the duration of the EXIT delay.
Any bypassed zones will be shown by the flashing zone indicators.
7. Leave the premises only via the EXIT/ENTRY zone.
8. During AWAY arming, the telephone line will be supervised hourly. If the telephone line
is disconnected, a new trouble condition will be registered (please refer to View System
Trouble).
9. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.

FASTKEY AWAY ARMING EITHER 1 PARTITION

[1] + [1 or 2] + [#]
(Press and hold down for 2 seconds)

1. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
2. Enter and hold down key [1] for 2 seconds.
3. Zone indicator [1] and [2] will flash. P1 and P2 options will be displayed.

4. Enter key [1] to arm Partition 1 or enter key [2] to arm Partition 2 followed by [#] key.
5. The P1 indicator will illuminate if Partition 1
is armed. The icon will be displayed if Partition
1 is armed.

An EXIT delay countdown timer will be


shown at the top right temporarily replace
the clock.
6. The P2 indicator will illuminate if Partition 2
is armed. The icon will be displayed if Partition
2 is armed.

An EXIT delay countdown timer will be


shown at the top right temporarily replace
the clock.
7. The keypad audible indicator will sound on and off for the duration of the EXIT delay.
Any bypassed zones will be shown by the flashing zone indicators.
8. Leave the premises only via the EXIT/ENTRY zone.
9. During AWAY arming, the telephone line will be supervised hourly. If the telephone line
is disconnected, a new trouble condition will be registered (please refer to View System
Trouble).
10. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.

31
Version 1.2
V16 Plus USER MANUAL

PARTITION DAY ARMING

[2] + [1 or 2] + [#]
(Press and hold down for 2 seconds)

1. This arming mode is ideal for DAY time arming with user still remains in the protected
premises.
2. In this mode, system will be armed instantly with certain preprogrammed, DAY STAY
zones bypassed automatically.
3. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
4. DO NOT open the ENTRY/EXIT zone.
5. Enter and hold down key [2] for 2 seconds.
6. Zone indicator [1] and [2] will flash. P1 and P2 options will be displayed.

7. Enter key [1] to arm Partition 1 or enter key [2] to arm Partition 2 followed by [#] key.
8. The P1 indicator will illuminate if Partition 1
is armed. The icon will be displayed if Partition
1 is armed.

9. The P2 indicator will illuminate if Partition 2


is armed. The icon will be displayed if Partition
2 is armed.

10. Any DAY STAY zones will be automatically bypassed (shown by flashing zone
indicators).
11. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.

PARTITION NIGHT ARMING

[3] + [1 or 2] + [#]
(Press and hold down for 2 seconds)

1. This arming mode is ideal for NIGHT time arming with user still remains in the protected
premises.
2. In this mode, system will be armed instantly with certain preprogrammed, NIGHT STAY
zones bypassed automatically.
3. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
4. DO NOT open the ENTRY/EXIT zone.
5. Enter and hold down key [3] for 2 seconds.
6. Zone indicator [1] and [2] will flash. P1 and P2 options will be displayed.

32
Version 1.2
V16 Plus USER MANUAL

7. Enter key [1] to arm Partition 1 or enter key [2] to arm Partition 2 followed by [#] key.
8. The P1 indicator will illuminate if Partition 1
is armed. The icon will be displayed if Partition
1 is armed.

9. The P2 indicator will illuminate if Partition 2


is armed. The icon will be displayed if Partition
2 is armed.

10. Any NIGHT STAY zones will be automatically bypassed (shown by flashing zone
indicators).
11. There is no ENTRY delay in this arming mode. Any violation on the active zones will
trigger the system instantly.

PARTITION FORCE ARMING

[4] + [1 or 2] + [#]
(Press and hold down for 2 seconds)

1. In this mode, the system will be armed with EXIT delay time which allows certain
violated zones to be bypassed temporary. When the violated zones resume, the zone
will be protected again.
2. Enter and hold down key [4] for 2 seconds.
3. Zone indicator [1] and [2] will flash. P1 and P2 options will be displayed.

4. Enter key [1] to arm Partition 1 or enter key [2] to arm Partition 2 followed by [#] key.
5. The P1 indicator will illuminate if Partition 1
is armed. The icon will be displayed if Partition
1 is armed.

An EXIT delay countdown timer will be


shown at the top right temporarily replace
the clock.
6. The P2 indicator will illuminate if Partition 2
is armed. The icon will be displayed if Partition
2 is armed.

33
Version 1.2
V16 Plus USER MANUAL

An EXIT delay countdown timer will be


shown at the top right temporarily replace
the clock.
7. Keypad audible indicator will sound on and off for the duration of the EXIT delay. Any
bypassed zones will be shown by the flashing zone indicators.
8. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.

PARTITION HOLIDAY ARMING

[0] + [1 or 2] + [#]
(Press and hold down for 2 seconds)

1. This arming mode is ideal for long away occasion (holiday).


2. In this mode, the system will be AWAY armed. Home Automation points will be random
ON/OFF every hour to simulate occupancy from 7pm to 1am.
3. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
4. Enter and hold down [0] key for 2 seconds.
5. Zone indicator [1] and [2] will flash. P1 and P2 options will be displayed.

6. Enter key [1] to arm Partition 1 or enter key [2] to arm Partition 2 followed by [#] key.
7. The P1 indicator will illuminate if Partition 1
is armed. The icon will be displayed if Partition
1 is armed.

An EXIT delay countdown timer will be


shown at the top right temporarily replace
the clock.
8. The P2 indicator will illuminate if Partition 2
is armed. The icon will be displayed if Partition
2 is armed.

An EXIT delay countdown timer will be


shown at the top right temporarily replace
the clock.
9. Keypad audible indicator will sound on and off for the duration of the EXIT delay. Any
bypassed zones will be shown by the flashing zone indicators.
10. Leave the premises only via the EXIT/ENTRY zone.

34
Version 1.2
V16 Plus USER MANUAL

11. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.
12. After disarming, Home Automation random ON/OFF function will be deactivated and the
system will resume to normal Home Automation ON/OFF timers setting.

PARTITION DISARMING

[USER CODE] + [#]

1. To disarm the system, enter a valid 4-digit [USER CODE] followed by [#] key before
expiry of the entry delay time.
2. Enter the premises through a designated ENTRY/EXIT zone; entering via other zones
will trigger an alarm instantly.
3. The ENTRY delay begins once the ENTRY zone is violated.
4. The keypad audible indicator will sound for the duration of the ENTRY delay to indicate
that a valid user code is required.
5. Zone indicator [1] and [2] will flash. P1 and P2 options will be displayed.

An ENTRY delay countdown timer will be


shown at the top right temporarily replace
the clock.
6. Enter key [1] to disarm Partition 1 or enter key [2] to disarm Partition 2 followed by [#]
key.
7. The P1 indicator will extinguish if Partition 1
is disarmed. The icon will extinguish if Partition 1
is disarmed.

8. The P2 indicator will extinguish if Partition 2


is disarmed. The icon will extinguish if Partition 2
is disarmed.

9. If the P1 or P2 indicators remain


illuminated, an error has been made while If the or icons remain
entering the user code, press [] key and illuminated, an error has been made while
re-enter the user code. entering the user code, press [] key and
re-enter the user code.

10. Once the system is disarmed, the keypad audible indicator will stop.
11. If no valid user code has been entered by the end of the ENTRY delay period, an
ALARM condition will be registered and stored into the system MEMORY.
12. If programmed to do so, the keypad will be locked and non-responsive for a
preprogrammed period for certain number of incorrect user codes, which are entered
consecutively more than the keypad lock counter (Please refer to Installer Programming
Section – Keypad Lock Counter).
13. If the ENTRY delay is too short, have your installer to change the ENTRY delay period.

35
Version 1.2
V16 Plus USER MANUAL

14. If the MEMORY indicator is flashing upon entry, there has been an intrusion. Call for
assistance. The intruder may still be inside.

USER CODE

Master code is a 4-digit personal identification number that allows you to enter certain programming
mode, arm or disarm the system and remotely control the system via telephone line. In additional to
Master Code, V16 Plus can be programmed to accept 13 user codes that allow you to arm/disarm the
system. The default Master Code is “1234”.

Door Access Code is a special 4-digit code that allows you to control a single door access system.
The Door Access Code cannot arm or disarm the security system.

Duress Code is an ambush code which will disarm the system and simultaneously send a silent alarm
signal to the center monitoring station. It is very useful code when you are forced to disarm your
security system under threat.

USER PROGRAMMING MODE

ENTER USER PROGRAMMING MODE

[] + [MODE] + [USER MASTER CODE] + [#]

1. Ensure that the system is not ARMED.

2. Press the [] key to cancel any unintended entries.


3. Press [MODE] key to go into USER PROGRAMMING mode.
4. Enter a valid 4-digit [USER MASTER CODE]. If you enter any mistakes, press [] key
and repeat step 3.
5. If a wrong USER MASTER CODE is entered, a long beep will be sound. Repeat step 3-
4 to enter USER PROGRAMMING MODE.
6. POWER and SERVICE indicators will slow Screen will show “User Mode” and
flash and the keypad audible indicator will keypad audible indicator will sound 2
sound 2 beeps if a valid USER MASTER beeps if a valid USER MASTER CODE is
CODE is entered. entered. Below the “User Mode”, the
“Passwords” command is ready to be
entered.

7. Enter COMMAND ADDRESS according to Use the [▲] key and [▼] key to scroll up
the setting that you wish to change. (Please and down. Enter the command that you
refer to User Programming Summary Table wish to change. (Please refer to User
(LED) at page 10 & 11) Programming Summary Table (LCD) at
page 13 to 15)

36
Version 1.2
V16 Plus USER MANUAL

8. To exit user programming mode, press To exit user programming mode press []
[MODE] followed by [#] key. or exit from MENU.

EXIT USER PROGRAMMING MODE

1. Press [MODE] followed by [#] key to exit. Press [] or exit from MENU.
2. POWER and SERVICE indicators will stop Screen will show “Menu” at the bottom
flashing. The keypad will sound 2 beeps to (exactly like before entering the user
confirm the exit command. programming mode) and keypad will
sound 2 beeps to confirm the exit
command.

PROGRAM NEW AND CHANGING EXISTING MASTER/USER CODE

1. Ensure that the system is in USER PROGRAMMING mode.

2. Enter [COMMAND ADDRESS] that you Press [#] to enter Passwords.


wish to change [01-14].

3. Enter the new 4-digit [USER CODE] and Press [#] to enter Master code 01 for
re-enter the new 4-digit [USER CODE] changing the master code.
followed by [#] key.

4. Repeat above steps to enter or change Enter the new 4-digit [MASTER CODE]
other user codes. e.g 4567 followed by [#] key.

5. To exit user programming mode, press Re-enter the new 4-digit [MASTER
[MODE] followed by [#] key. CODE] followed by [#] key.

37
Version 1.2
V16 Plus USER MANUAL

6. - Use the [▲] key and [▼] key to scroll up


and down to select other user code and
repeat step 3.
7. - Press [] to exit user programming mode.
8. If any of the user codes are not used, please ensure that they are all erased.

PROGRAM NEW AND CHANGING EXISTING DOOR ACCESS CODE

1. Ensure that the system is in USER PROGRAMMING mode.

2. Enter command address [15]. Press [#] to enter Passwords.

3. Enter the new 4-digit [DOOR ACCESS Press [▼] to scroll down to User Code
CODE] and re-enter the new 4-digit [DOOR 15.
ACCESS CODE] followed by [#] key.

4. To exit user programming mode, press Press [#] to enter User Code 15.
[MODE] followed by [#] key.

5. - Enter the new 4-digit [DOOR ACCESS


CODE] e.g 1212 and press [#].

6. - Re-enter the new 4-digit [DOOR


ACCESS CODE] e.g 1212 and press [#].

38
Version 1.2
V16 Plus USER MANUAL

7. - Press [] to exit user programming mode.


8. If any of the user codes are not used, please ensure that they are all erased.

PROGRAM NEW AND CHANGING EXISTING DURESS CODE

1. Ensure that the system is in USER PROGRAMMING mode.

2. Enter command address [16]. Press [#] to enter Passwords.

3. Enter the new 4-digit [DURESS CODE] Press [▼] to scroll down to Duress Code.
and re-enter the new 4-digit [DURESS
CODE] followed by [#] key.

4. To exit user programming mode, press Press [#] to enter Duress Code.
[MODE] followed by [#] key.

5. - Enter the new 4-digit [DURESS CODE]


e.g 1313 and press [#].

6. - Re-enter the new 4-digit [DURESS


CODE] e.g 1313 and press [#].

7. - Press [] to exit user programming mode.


8. If any of the user codes are not used, please ensure that they are all erased.

39
Version 1.2
V16 Plus USER MANUAL

ERASE USER, DOOR ACCESS or DURESS CODE

1. Ensure that the system is in USER PROGRAMMING mode.

2. Enter [COMMAND ADDRESS] that you Press [#] to enter Passwords.


wish to erase followed by [#] key.

3. Enter the 4-digit [0000] and re-enter the 4- Press [▼] to scroll down to select which
digit [0000] followed by [#] key. user code that you wish to erase e.g User
Code 02.

4. Repeat step 2-3 to erase other user codes. Press [#] to enter User Code 02.

5. To exit user programming mode, press Enter the 4-digit [0000] followed by [#]
[MODE] followed by [#] key. key.

6. - Re-enter the 4-digit [0000] followed by [#]


key.
7. - Repeat step 3 to erase other user codes.
8. - Press [] to exit user programming mode.

9. If any of the user codes are not used, please ensure that they are all erased. (Master
code cannot be erased)

PROGRAM SYSTEM TIMER

1. Ensure that the system is in USER PROGRAMMING mode.

2. Enter [17] for system timer setting. Press [▼] to scroll down to Clock.

40
Version 1.2
V16 Plus USER MANUAL

3. Enter the [CURRENT TIME] in 24-hour Press [#] to enter Clock for system timer
format, e.g. 8:00pm is 20:00. setting.

4. Enter [#] key to confirm the time. Enter the [CURRENT TIME] in 24-hour
format e.g. 8:00pm is 20:00.

5. To exit user programming mode, press Enter [#] key to confirm the time.
[MODE] followed by [#] key.

6. - Press [] to exit user programming mode.

PROGRAM PARTITION 1 AUTO ARM TIMER

1. Ensure that the system is in USER PROGRAMMING mode.

2. Enter [18] for auto arm timer setting. Press [▼] to scroll down to Timers.

3. Enter the [AUTO ARM TIMER] in 24-hour Press [#] to enter Timers.
format, e.g. 8:00pm is 20:00.

4. Enter [#] key to confirm the time. Press [#] to enter Arm P1 Tmr for auto
arm timer setting.

41
Version 1.2
V16 Plus USER MANUAL

5. To exit user programming mode, press Enter the [AUTO ARM TIMER] in 24-hour
[MODE] followed by [#] key. format, e.g. 8:00pm is 20:00.

6. - Enter [#] key to confirm the time.

7. - Press [] to exit user programming mode.

TO ERASE PARTITION 1 AUTO ARM TIMER

1. Ensure that the system is in USER PROGRAMMING mode.

2. Enter [18] for auto arm timer setting. Press [▼] to scroll down to Timers.

3. Enter the [#] key to erase previous AUTO Press [#] to enter Timers.
ARM TIMER setting.

4. To exit user programming mode, press Press [#] to enter Arm P1 Tmr for auto
[MODE] followed by [#] key. arm timer setting.

5. - Press the [F] key to disable auto disarm


timer setting. The setting will be set to
99:99.

 99:99.

6. - Enter the [#] key to erase previous AUTO


ARM TIMER setting.
7. - Press [] to exit user programming mode.

42
Version 1.2
V16 Plus USER MANUAL

PROGRAM PARTITION 1 AUTO DISARM TIMER

1. Ensure that the system is in USER PROGRAMMING mode.

2. Enter [19] for auto disarm timer setting. Press [▼] to scroll down to Timers.

3. Enter the [AUTO DISARM TIMER] in 24- Press [#] to enter Timers.
hour format, e.g. 8:00pm is 20:00.

4. Enter [#] key to confirm the time. Press [▼] to scroll down to Disarm P1
Tmr.

5. To exit user programming mode, press Press [#] to enter Disarm P1 Tmr for
[MODE] followed by [#] key. auto disarm timer setting.

6. - Enter the [AUTO DISARM TIMER] in 24-


hour format, e.g. 8:00pm is 20:00.

7. - Enter [#] key to confirm the time.


8. - Press [] to exit user programming mode.

43
Version 1.2
V16 Plus USER MANUAL

TO ERASE PARTITION 1 AUTO DISARM TIMER

1. Ensure that the system is in USER PROGRAMMING mode.

2. Enter [19] for auto disarm timer setting. Press [▼] to scroll down to Timers.

3. Enter the [#] key to erase previous AUTO Press [#] to enter Timers.
DISARM TIMER setting.

4. To exit user programming mode, press Press [▼] to scroll down to Disarm P1
[MODE] followed by [#] key. Tmr.

5. - Press [#] to enter Disarm P1 Tmr for


auto disarm timer setting.

6. - Press the [F] key to disable auto disarm


timer setting. The setting will be set to
99:99.

 99:99.

7. - Enter the [#] key to erase previous AUTO


DISARM TIMER setting.
8. - Press [] to exit user programming mode.

44
Version 1.2
V16 Plus USER MANUAL

PROGRAM PARTITION 2 AUTO ARM TIMER

1. Ensure that the system is in USER PROGRAMMING mode.

2. Enter [20] for auto arm timer setting. Press [▼] to scroll down to Timers.

3. Enter the [AUTO ARM TIMER] in 24-hour Press [#] to enter Timers.
format, e.g. 8:00pm is 20:00.

4. Enter [#] key to confirm the time. Press [▼] to scroll down to Arm P2
Timer.

5. To exit user programming mode, press Press [#] to enter Arm P2 Timer for auto
[MODE] followed by [#] key. arm timer setting.
6. -

7. - Enter the [AUTO ARM TIMER] in 24-hour


format, e.g. 8:00pm is 20:00.
8.

9. - Enter [#] key to confirm the time.


10. - Press [] to exit user programming mode.

45
Version 1.2
V16 Plus USER MANUAL

TO ERASE PARTITION 2 AUTO ARM TIMER

1. Ensure that the system is in USER PROGRAMMING mode.

2. Enter [20] for auto arm timer setting. Press [▼] to scroll down to Timers.

3. Enter the [#] key to erase previous AUTO Press [#] to enter Timers.
ARM TIMER setting.

4. To exit user programming mode, press Press [▼] to scroll down to Arm P2
[MODE] followed by [#] key. Timer.

5. - Press [#] to enter Arm P2 Timer for auto


arm timer setting.

6. - Press the [F] key to disable auto arm


timer setting. The setting will be set to
99:99.

 99:99.

7. - Enter the [#] key to erase previous AUTO


ARM TIMER setting.
8. - Press [] to exit user programming mode.

46
Version 1.2
V16 Plus USER MANUAL

PROGRAM PARTITION 2 AUTO DISARM TIMER

1. Ensure that the system is in USER PROGRAMMING mode.

2. Enter [21] for auto disarm timer setting. Press [▼] to scroll down to Timers.

3. Enter the [AUTO DISARM TIMER] in 24- Press [#] to enter Timers.
hour format, e.g. 8:00pm is 20:00.

4. Enter [#] key to confirm the time. Press [▼] to scroll down to Disarm P2
Tmr.

5. To exit user programming mode, press Press [#] to enter Disarm P2 Tmr for
[MODE] followed by [#] key. auto disarm timer setting.
6. -

7. - Enter the [AUTO DISARM TIMER] in 24-


hour format, e.g. 8:00pm is 20:00.
8.

9. - Enter [#] key to confirm the time.


10. - Press [] to exit user programming mode.

47
Version 1.2
V16 Plus USER MANUAL

TO ERASE PARTITION 2 AUTO DISARM TIMER

1. Ensure that the system is in USER PROGRAMMING mode.

2. Enter [21] for auto disarm timer setting. Press [▼] to scroll down to Timers.

3. Enter the [#] key to erase previous AUTO Press [#] to enter Timers.
DISARM TIMER setting.

4. To exit user programming mode, press Press [▼] to scroll down to Disarm P2
[MODE] followed by [#] key. Tmr.

5. - Press [#] to enter Disarm P2 Tmr for


auto disarm timer setting.

6. - Press the [F] key to disable auto disarm


timer setting. The setting will be set to
99:99.

 99:99.

7. - Enter the [#] key to erase previous AUTO


DISARM TIMER setting.
8. - Press [] to exit user programming mode.

48
Version 1.2
V16 Plus USER MANUAL

PROGRAM AUTO ON TIMER 1/2/3/4 FOR HOME AUTOMATION

1. Ensure that the system is in USER PROGRAMMING mode.

2. Enter [22] for auto on timer 1 setting.* Press [▼] to scroll down to Timers.

3. Enter the [AUTO ON TIMER 1] in 24-hour Press [#] to enter Timers.


format, e.g. 8:00pm is 20:00.

4. Enter [#] key to confirm the time. Press [▼] to scroll down to ON HA Tmr
1. **

5. To exit user programming mode, press Press [#] to enter ON HA Tmr 1 for auto
[MODE] followed by [#] key. on timer 1 setting.

6. - Enter the [AUTO ON TIMER 1] in 24-hour


format, e.g. 8:00pm is 20:00.

7. - Enter [#] key to confirm the time.


8. - Press [] to exit user programming mode.

* Enter [24] for auto on timer 2 setting OR


Enter [26] for auto on timer 3 setting OR
Enter [28] for auto on timer 4 setting.

** Press [▼] to scroll down to ON HA Tmr 2 and press [#] to enter for auto on timer 2 setting OR
Press [▼] to scroll down to ON HA Tmr 3 and press [#] to enter for auto on timer 3 setting OR
Press [▼] to scroll down to ON HA Tmr 4 and press [#] to enter for auto on timer 4 setting.

49
Version 1.2
V16 Plus USER MANUAL

TO ERASE AUTO ON TIMER 1/2/3/4 FOR HOME AUTOMATION


1. Ensure that the system is in USER PROGRAMMING mode.

2. Enter [22] for auto on timer 1 setting.* Press [▼] to scroll down to Timers.

3. Enter the [#] key to erase previous AUTO Press [#] to enter Timers.
ON TIMER 1 setting.

4. To exit user programming mode, press Press [▼] to scroll down to ON HA Tmr
[MODE] followed by [#] key. 1. **

5. - Press [#] to enter ON HA Tmr 1 for auto


on timer 1 setting.

6. - Press the [F] key to disable AUTO ON


TIMER 1 setting. The setting will be set to
99:99.

7. - Enter the [#] key to erase previous AUTO


ON TIMER 1 setting.
8. - Press [] to exit user programming mode.

* Enter [24] for auto on timer 2 setting OR


Enter [26] for auto on timer 3 setting OR
Enter [28] for auto on timer 4 setting.

** Press [▼] to scroll down to ON HA Tmr 2 and press [#] to enter for auto on timer 2 setting OR
Press [▼] to scroll down to ON HA Tmr 3 and press [#] to enter for auto on timer 3 setting OR
Press [▼] to scroll down to ON HA Tmr 4 and press [#] to enter for auto on timer 4 setting.

50
Version 1.2
V16 Plus USER MANUAL

PROGRAM AUTO OFF TIMER 1/2/3/4 FOR HOME AUTOMATION

1. Ensure that the system is in USER PROGRAMMING mode.

2. Enter [23] for auto off timer 1 setting.* Press [▼] to scroll down to Timers.

3. Enter the [AUTO OFF TIMER 1] in 24-hour Press [#] to enter Timers.
format, e.g. 8:00pm is 20:00.

4. Enter [#] key to confirm the time. Press [▼] to scroll down to OFF HA Tmr
1.**

5. To exit user programming mode, press Press [#] to enter OFF HA Tmr 1 for auto
[MODE] followed by [#] key. off timer 1 setting.

6. - Enter the [AUTO OFF TIMER 1] in 24-


hour format, e.g. 8:00pm is 20:00.

7. - Enter [#] key to confirm the time.


8. - Press [] to exit user programming mode.

* Enter [25] for auto off timer 2 setting OR


Enter [27] for auto off timer 3 setting OR
Enter [29] for auto off timer 4 setting.

** Press [▼] to scroll down to OFF HA Tmr 2 and press [#] to enter for auto off timer 2 setting OR
Press [▼] to scroll down to OFF HA Tmr 3 and press [#] to enter for auto off timer 3 setting OR
Press [▼] to scroll down to OFF HA Tmr 4 and press [#] to enter for auto off timer 4 setting.

51
Version 1.2
V16 Plus USER MANUAL

TO ERASE AUTO OFF TIMER 1/2/3/4 FOR HOME AUTOMATION

1. Ensure that the system is in USER PROGRAMMING mode.

2. Enter [23] for auto off timer 1 setting.* Press [▼] to scroll down to Timers.

3. Enter the [#] key to erase previous AUTO Press [#] to enter Timers.
OFF TIMER 1 setting.

4. To exit user programming mode, press Press [▼] to scroll down to OFF HA Tmr
[MODE] followed by [#] key. 1. **

5. - Press [#] to enter OFF HA Tmr 1 for auto


off timer 1 setting.

6. - Press the [F] key to disable AUTO OFF


TIMER 1 setting. The setting will be set to
99:99.

7. - Enter the [#] key to erase previous AUTO


OFF TIMER 1 setting.
8. - Press [] to exit user programming mode.

* Enter [25] for auto off timer 2 setting OR


Enter [27] for auto off timer 3 setting OR
Enter [29] for auto off timer 4 setting.

** Press [▼] to scroll down to OFF HA Tmr 2 and press [#] to enter for auto off timer 2 setting OR
Press [▼] to scroll down to OFF HA Tmr 3 and press [#] to enter for auto off timer 3 setting OR
Press [▼] to scroll down to OFF HA Tmr 4 and press [#] to enter for auto off timer 4 setting.

52
Version 1.2
V16 Plus USER MANUAL

PROGRAM PERSONAL TELEPHONE NUMBER 1/2/3/4

1. Ensure that the system is in USER PROGRAMMING mode.

2. Enter [30] for personal telephone number 1 Press [▼] to scroll down to TelNos.
setting.*

3. Enter the [PERSONAL TELEPHONE Press [#] to enter TelNos.


NUMBER 1], the maximum telephone
number length is 14 digits.

4. Button “P” on the keypad is representing a Press [#] to enter User TelNo1.**
“PAUSE” key of 5 seconds duration.

5. Button “M” on the keypad is representing a Enter the [PERSONAL TELEPHONE


“ ” key. NUMBER 1], the maximum telephone
number length is 14 digits. The entered
number will be displayed on the screen.

6. Enter [#] key to confirm the setting. Press the [F] key to temporary erase
setting or wrong keyed in numbers.

7. To exit user programming mode, press Button “▲” on the keypad is representing
[MODE] followed by [#] key. a “PAUSE” key of 5 seconds duration.

8. - Button “▼” on the keypad is representing


a“ ” key.

9. - Enter [#] key to confirm the setting.


10. - Press [] to exit user programming mode.

11. If programmed so, system will call out to user telephone to report any intrusion.

53
Version 1.2
V16 Plus USER MANUAL

12. If the system fails to contact the preprogrammed personal telephone number 1, system
will contact PERSONAL TELEPHONE NUMBER 2 to 4 as a backup. If the system fails
to report to all telephone numbers, a new trouble condition will be registered (please
refer to View System Trouble).

* Enter [31] for personal telephone number 2 setting OR


Enter [32] for personal telephone number 3 setting OR
Enter [33] for personal telephone number 4 setting.

** Press [▼] to scroll down to User TelNo2 and press [#] to enter for personal telephone number 2 setting OR
Press [▼] to scroll down to User TelNo3 and press [#] to enter for personal telephone number 3 setting OR
Press [▼] to scroll down to User TelNo4 and press [#] to enter for personal telephone number 4 setting.

TO ERASE PERSONAL TELEPHONE NUMBER 1/2/3/4

1. Ensure that the system is in USER PROGRAMMING mode.

2. Enter [30] for personal telephone number 1 Press [▼] to scroll down to TelNos.
setting.*

3. Enter the [#] key to erase previous Press [#] to enter TelNos.
personal telephone number 1 setting.

4. To exit user programming mode, press Press [#] to enter User TelNo1.**
[MODE] followed by [#] key.

5. - Press the [F] key to erase and the setting


will be emptied.

6. - Enter the [#] key to erase previous


personal telephone number 1 setting.

7. - Press [] to exit user programming mode.

54
Version 1.2
V16 Plus USER MANUAL

* Enter [31] for personal telephone number 2 setting OR


Enter [32] for personal telephone number 3 setting OR
Enter [33] for personal telephone number 4 setting.

** Press [▼] to scroll down to User TelNo2 and press [#] to enter for personal telephone number 2 setting OR
Press [▼] to scroll down to User TelNo3 and press [#] to enter for personal telephone number 3 setting OR
Press [▼] to scroll down to User TelNo4 and press [#] to enter for personal telephone number 4 setting.

PROGRAM SYSTEM DATE (FOR LCD ONLY)

1. Ensure that the system is in USER PROGRAMMING mode.

2. Press [▼] to scroll down to Date.

3. Press [#] to enter Date.

4. Enter the [DATE] in DDMMYY format, e.g 22nd February 2010 is 220210.

5. Enter the [#] key to confirm the date.


6. Press [] to exit user programming mode.
7.
PROGRAM SECURITY AND HOME AUTOMATION TIMER SCHEDULE (FOR LCD ONLY)

1. Ensure that the system is in USER PROGRAMMING mode.

2. Press [▼] to scroll down to Schedule.

3. Press [#] to access Schedule menu.

55
Version 1.2
V16 Plus USER MANUAL

4. Press [#] to access Arm P1 Timer Schedule for auto arm partition 1 timer schedule.

5. The default setting is number 1 to 7 ON (1 for Monday, 2 for Tuesday, 3 for Wednesday, 4 for
Thursday, 5 for Friday, 6 for Saturday and 7 for Sunday). It means that Arm P1 Timer will be
activated from Monday to Sunday.

6. If you want to activate the Arm P1 Timer from Monday to Friday (weekdays) only, press 6 and
7 to turn OFF number 6 (Saturday) and 7 (Sunday).
7. Press [#] key to confirm the schedule.
8. Press [▼] to scroll down to program Disarm P1 Timer Schedule, Arm P2 Timer Schedule,
Disarm P2 Timer Schedule, ON HA Timer 1/2/3/4 Schedule and OFF HA Timer 1/2/3/4
Schedule.

9. Press [] to exit user programming mode.

TESTING THE SYSTEM

Users are advised to test the system as frequent as possible. System must be tested at least once
every 3 months. If the system is not functioning accordingly, please contact your system installer for
technical assistance.

WALK TEST

1. Walk Test allows on-site testing of each zone of the system.


2. Press [MODE] + [1] + [#]. Press [MODE] + [1] + [#] or enter from
MENU.
(Menu  System Test  Walk Test)

3. Siren will trigger for 2 seconds and keypad buzzer will sound briefly if any zone is
violated during walk test mode.
4. If siren and keypad do not sound when zone is violated, consult your system installer.
5. To exit Walk Test, simply press [#] key.

56
Version 1.2
V16 Plus USER MANUAL

CMS TEST (Manual Test)

1. CMS Test allows on-site testing of CMS Reporting.


2. Press [MODE] + [2] + [#]. Press [MODE] + [2] + [#] or enter from
MENU.
(Menu  System Test  CMS Test)

3. A CMS testing code will be sent to the central monitoring station.


4. Wait for 2 minutes, if CMS reporting fails then a new trouble condition will be registered.
5. Press and hold down [7] key for 2 seconds to view trouble condition and consult your
system installer.
6. Please refer to View System Trouble.

SIREN TEST

1. Siren Test allows on-site testing of siren functionality.


2. Press [MODE] + [3] + [#]. Press [MODE] + [3] + [#] or enter from
MENU.
(Menu  System Test  Siren Test)

3. Siren will sound for 3 seconds.


4. If siren does not sound, consult your system installer.

STROBE LIGHT TEST

1. Strobe Light Test allows on-site testing of strobe light functionality.


2. Press [MODE] + [4] + [#]. Press [MODE] + [4] + [#] or enter from
MENU.
(Menu  System Test  Strobe Test)

3. Strobe light will flash for 15 seconds.


4. If strobe light does not flash, consult your system installer.

57
Version 1.2
V16 Plus USER MANUAL

BATTERY TEST

1. Battery Test allows on-site testing of battery functionality.


2. Press [MODE] + [5] + [#]. Press [MODE] + [5] + [#] or enter from
MENU.
(Menu  System Test  Battery Test)

3. Wait for 5 seconds, if back-up battery fails then a new trouble condition will be
registered.
4. Press and hold down [7] key for 2 seconds to view the trouble condition and consult
your system installer.

SYSTEM INFORMATION

SECURITY ZONE INFORMATION

Zone Partition Zone Type Location


No. 1 or 2 or both e.g. Entry/Exit Delay e.g. Main door
1

10

11

12

13

14

15

16

58
Version 1.2
V16 Plus USER MANUAL

SYSTEM SETTING INFORMATION

Partition 1
Entry Time Partition 1 : _____________________________ seconds
Exit Time Partition 1 : _____________________________ seconds
Siren Cut-Off Time for Partition 1 : _____________________________ minutes

Partition 2
Entry Time Partition 2 : _____________________________ seconds
Exit Time Partition 2 : _____________________________ seconds
Siren Cut-Off Time for Partition 2 : _____________________________ minutes

Telephone Reporting
Telephone Number 1 : _____________________________
Telephone Number 2 : _____________________________
Telephone Number 3 : _____________________________
Telephone Number 4 : _____________________________
Dialing Attempt : _____________________________ times

Home Automation
Home Automation 1 Turn On Time ___ ___ : ___ ___ am / pm
Home Automation 1 Turn Off Time ___ ___ : ___ ___ am / pm
Home Automation 2 Turn On Time ___ ___ : ___ ___ am / pm
Home Automation 2 Turn Off Time ___ ___ : ___ ___ am / pm
Home Automation 3 Turn On Time ___ ___ : ___ ___ am / pm
Home Automation 3 Turn Off Time ___ ___ : ___ ___ am / pm
Home Automation 4 Turn On Time ___ ___ : ___ ___ am / pm
Home Automation 4 Turn Off Time ___ ___ : ___ ___ am / pm

CMS
Central Monitoring Station Number : _____________________
Central Monitoring Station Account Number : _____________________

Servicing
Installer company : _____________________________________________
Contact person : _____________________________________________
Contact number : _____________________________________________
Installation Date : ______ / ______ / ______