We deliver:
• Electrical solutions that use less energy, improve power reliability
and make the places we live and work safer and more comfortable
• Hydraulic and electrical solutions that enable machines to deliver
more productivity without wasting power
• Aerospace solutions that make aircraft lighter, safer and less costly
to operate, and help airports operate more efficiently
• Vehicle drivetrain and powertrain solutions that deliver more power
to cars, trucks and buses, while reducing fuel consumption and emissions
GalleonTM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Emergency lighting
AG Bulkhead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
i-P65 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Zetalite 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Lighting controls . . . . . . . . . . . . . . . . . . . . . . . . . 64
This versatile industrial LED luminaire is ideally suited • IP65 rugged construction - ideal for cold stores
to all industrial and warehouse applications. It is down to -30°c, though equally suited in ambient
offered with a choice of lumen packages controlled up to +30°C
by open area, rack aisle or narrow distribution • Instant white light, no re-strike or run up delay
reflector options and is designed to accommodate are distinct advantages over HID solutions
different mounting heights and installation methods
• No lamp changes provides virtually maintenance
resulting in a luminaire system that can be tailored to free operation, long LED life, ~5.7 years
virtually any application. operating 24/7
The variable length housing accommodates integral • Compact and robust die cast and extruded
control gear and sensor controls when necessary. aluminium housing
Energy savings can be further enhanced by the use • Racking aisle or open area optic choice to
of occupancy detection, dimmable control gear and/ maximise spacing and uniformity
or switching arrangements to minimise electricity
• Variable mounting heights, ideal for warehouse
consumption. These are benefits over traditional
racking and marshalling areas - suitable from
discharge lamps where controls are limited. 2.5m to 14m+
The highly efficient LED multi-die arrays deliver
excellent performance and efficacy, combined • Choice of lumen packages from multi-die LED
arrays
with the excellent thermal management and driver
compatibility the LEDs deliver a long, virtually • 5000K cool white multi-die LED technology with
maintenance free, 50,000 plus hours LED life 65 CRI or 80 CRI options
at L70. • Emergency versions available with two optic
choices to suit mounting heights up to 25m
white RAL9016 powder coat finish
165mm
• Aluminium reflectors
174mm
• Internal gear tray - mild steel in white RAL9016 powder coat
165mm
Litex LED - Wide Optic Litex LED - Narrow Optic Litex LED - Rack Optic
Installation notes SHR nom: 1:1.25
SHR nom: 1:1.25
• Fused as standard
• For operation in ambient temperatures of -30°C to +30°C
• Emergency versions must be operated in an ambient of +5°C
to +25°C to keep the batteries within operating temperatures
540mm
• 2m lead supplied fitted to luminaire head at the gear area end
200mm
Control Gear
200mm 540mm
Control Gear
• Installations utilising the ‘rack optic’ should be installed with
the length of the luminaire running parallel with the length of
the aisle 20mm
20mm
height. “D” sensor is IP65 rated and ideal for mounting heights
of up to 5m
• Choice of up to 4 multi-die LEDs, all driven at 700mA 20mm
Catalogue numbers
Emergency 1 Range 3 No of LEDs Drive Current Optic LED Colour 4 Control Gear Options
EL = 3hr LTX = 1 = 1 LED 3 = 700mA W = Wide Reflector Optic 1 = 5000K Ra65 Z = High frequency fixed output EC2 = EasiCheck2
Maintained Litex LED 2 = 2 LEDs N = Narrow Reflector Optic 2 = 5000K Ra80 DD = DALI Digital Dimming IS = Self Test
<9 Mounting 3 = 3 LEDs R = Rack Aisle Reflector Optic R = 1-10V Dimming
Height 4 = 4 LEDs
ELH = 3hr
Maintained Please ensure hyphen is
9 - 25m included in the part number
Mounting
Height
PIR 2
S = PIR Sensor (IP20)
D = PIR/Photocell Sensor (IP65)
1 Emergency versions have a dedicated LED activated in emergency mode with a choice of 2 optics to suit the mounting height
2 The ‘S’ prefix PIR switching sensor is IP20 rated and therefore will effect the overall IP rating of the luminaire, operates down to -30°C
The ‘D’ prefix sensor is IP65 rated and suitable for up to 5m mounting heights, operating temperature 0°C to +30°C
3 All standard luminaires are IP65 rated - also refer to note 2
4 Alternative colour temperature and CRI options may be considered - this will be to special order
Note: Higher CRI variants will have a reduced lumen output
Luminaire example
CONTROLS
Eaton’s commitment to supplying innovative energy • Utilisation of LED Light Engine technology
innovative products is the driving force behind allows for an increased energy efficiency - up to
Linergy LED. Linergy LED follows in the tradition 115Llm/cW
of our highly efficient large space luminaires which • Excellent light transmission and LED source
have the performance and flexibility for today’s multi- obscurity from opal diffuser
use, multi occupancy locations.
• Enhanced Capital Allowance (ECA) compliance
Offering both a range of lumen outputs and light across the complete range
distribution, Linergy LED variants can be used • Three reflector options allowing complete
seamlessly alongside each other to give a complete flexibility for the required application
solution in complex spaces. • Integral emergency available which allows
High lumen outputs and corresponding class mounting to a maximum height of 20m
leading efficacies, when combined with occupancy • Low, mid and high bay integral programmable
and daylight sensors, offer the real possibility of occupancy detector variants available to
substantial energy savings for the end user. maximise performance and coverage
Three light distribution models, Wide Area, Narrow • DALI dimming options available for increased
and Rack, means the highest utilisation of light comfort, lighting control and energy savings
where it is most effective. • Wire guard option for increased security in
environments where impact resistance is
needed
L (mm)
Linergy LED has the option of an integral emergency built centrally Energy saving is key to sustainable buildings and businesses. By
into the body of the luminaire. Utilising the efficient Eaton optical adopting a clear strategy for managing the occupancy and absence
system, capital and installation costs are reduced with class of a space, significant savings may be achieved in energy usage.
leading spacing’s achievable. Two variants allow for maximised Application dependent, savings against constant illumination can
utilisation in the space, up to 10m mounting height and up to 20m be up to 70%.
mounting height.
Standard high frequency PIRs have a daylight linking function,
For applications to 10m mounting height, the optic distribution with thresholds determinable by the user, as well as a switching
is a square footprint allowing the designer scope for achieving function. In DALI luminaires, the PIRs have a daylight linking
compliance with reduced quantities of emergency points. function, with thresholds determinable by the user, as well as a full
dimming function.
Applications with mounting heights above this, up to 20m, the
optic is utilised to be elongated in one plane. This allows optimum
spacing, following the linear installation direction.
For application mounting heights of up to 10m the standard variant
should be used, the prefix is ‘ELL’. Emergency operation for
mounting heights up to 20m, the prefix ‘ELH’ should be used. See
the catalogue numbers for more detail.
Mounting heights
Linergy LED offers three standard options for PIR detection mounting heights. Up to 3 meters, 9
meters and 16 meters. The 3m detector boasts a high sensitivity Micro detection range. The aspect
ratios and coverage are shown on the diagrams to aid in scheme design.
3.0m
8.4m
Micro
9m
19m
16m
30m
Accessories
Catalogue Numbers
Description Cat No
Wire guard - 1200lm LNLWG4
Wire guard - 1800lm LNLWG6
Infrared user controller LCSQC
Infrared programmer LCSQS
Digital 2 way programmer LCSQSP
Rear mounting brackets LNLMB
Luminaire efficacy
Variant Lumen output Wattage (w) Llm/cW
Wide Area
LNLA1504KZ 15065 144 104.62
LNLA2254KZ 22785 210 108.5
Narrow
LNLN1504KZ 15309 144 106.31
LNLN2254KZ 23032 210 109.68
Rack
LNLR1504KZ 14808 135 109.69
LNLR2254KZ 22960 198 115.96
Catalogue numbers
Lumen Output (lm) Optic Cat No. Weight (Kg) Emergency Cat No. Weight (Kg)
Standard Luminaires
1200mm Wide Area Reflector LNLA1504KZ 5.5 ELLNLA1504KZ 6.2
1800mm Wide Area Reflector LNLA2254KZ 8.1 ELLNLA2254KZ 9.0
1200mm Narrow Reflector LNLN1504KZ 5.5 ELLNLN1504KZ 6.2
1800mm Narrow Reflector LNLN2254KZ 8.1 ELLNLN2254KZ 9.0
1200mm Rack Reflector LNLR1504KZ 5.7 ELLNLR1504KZ 6.4
1800mm Rack Reflector LNLR2254KZ 8.2 ELLNLR2254KZ 9.1
Luminaire with switching high level sensor (up to 16m mounting height)
1200mm Wide Area Reflector ULNLA1504KZ 5.7 ELHULNLA1504KZ 6.4
1800mm Wide Area Reflector ULNLA2254KZ 8.5 ELHULNLA2254KZ 9.4
1200mm Narrow Reflector ULNLN1504KZ 5.7 ELHULNLN1504KZ 6.4
1800mm Narrow Reflector ULNLN2254KZ 8.5 ELHULNLN2254KZ 9.4
1200mm Rack Reflector ULNLR1504KZ 5.9 ELHULNLR1504KZ 6.6
1800mm Rack Reflector ULNLR2254KZ 8.6 ELHULNLR2254KZ 9.5
CONTROLS
IHB series LED luminaires are engineered to provide • High efficacy: up to 117 lm/W
maintenance-free performance while delivering long • Light colour 5000 K / 80 CRI
life and high lumen performance - making them an
• Up to 67% energy savings over traditional
efficient and reliable high bay solution.
HID fixtures
IHB series LED luminaires are the perfect • Complete portfolio replaces 250W - 1000W,
replacement for 250W - 1500W+ HID and 2-10 lamp enables the replacement of conventional HID
T8, T12 and T5HO fluorescent high bay fixtures. floodlights from 250W up to 1000W respective
Designed for locations requiring continuous and fluorescent light fittings from 4 up to 10 T5
consistent light levels, requiring frequent on/off lamps
switching of lights and areas that are inaccessible for • Typical customer payback of 1-3 years and lower
maintenance. total cost of ownership compared to HID and
fluorescent lighting
• Versatile mounting options
• Optional 0-10V dimming capabilities
• Operating ambient: -40°C to +60°C*
Materials Specification
• Housing - anodised aluminium, grey To specify state: High bay LED luminaire, anodised aluminium
housing, grey, wide-angle (narrow-angle on request), dimmable,
• Protective cover: borosilicate glass, polycarbonate on request
zero maintenance, reduced energy consumption, part no.
• Permissible ambient temperature from -40°C up to +60°C _________
Technical data
IHB16L/UNV1 IHB24L/UNV1 IHB32L/UNV1
Permissible ambient temperature -40 °C up to +60 °C -40 °C up to +60 °C -40 °C up to +60 °C
Lifetime fixtures 120,000 h at ta = +25 °C 120,000 h at ta = +25 °C 120,000 h at ta = +25 °C
65,000 h at ta = +40 °C 65,000 h at ta = +40 °C 65,000 h at ta = +40 °C
Rated voltage 100 - 277 V AC; 127 - 250 VDC 100 - 277 V AC; 127 - 250 VDC 100 - 277 V AC; 127 - 250 VDC
Frequency 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz
Power 145 W 216 W 289 W
Circuit Electronic driver Electronic driver Electronic driver
Light source LED LED LED
Light colour 5000 K / Ra 80 5000 K / Ra 80 5000 K / Ra 80
Optic Wide-angle (narrow-angle on request) Wide-angle (narrow-angle on request) Wide-angle (narrow-angle on request)
Rated luminous flux of the luminaire 16,900 lm 25,350 lm 33,800 lm
Dimensions (L x W x H) 478 x 339 x 108 mm 478 x 517 x 108 mm 478 x 695 x 108 mm
Terminals L, N, PE, max. 1 x 2.5 mm 2
L, N, PE, max. 1 x 2.5 mm 2
L, N, PE, max. 1 x 2.5 mm2
Terminals for dimmer, 2 x 2.5 mm2 max. Terminals for dimmer, 2 x 2.5 mm2 max. Terminals for dimmer, 2 x 2.5 mm2 max.
Enclosure colour Grey Grey Grey
Enclosure material Anodised aluminium Anodised aluminium Anodised aluminium
Weight 7.7 kg 12.3 kg 16.3 kg
Protective cover / protective bowl Tempered glass, clear 1) Tempered glass, clear 1) Tempered glass, clear 1)
IHB48L/UNV1 IHB64L/UNV1
Permissible ambient temperature -40 °C up to +60 °C -40 °C up to +60 °C
Lifetime fixtures 120,000 h at ta = +25 °C 120,000 h at ta = +25 °C
65,000 h at ta = +40 °C 65,000 h at ta = +40 °C
Rated voltage 100 - 277 V AC; 127 - 250 VDC 100 - 277 V AC; 127 - 250 VDC
Frequency 50 - 60 Hz 50 - 60 Hz
Power 436 W 582 W
Circuit Electronic driver Electronic driver
Light source LED LED
Light colour/CRI 5000 K / Ra 80 5000 K / Ra 80
Optic Wide-angle (narrow-angle on request) Wide-angle (narrow-angle on request)
Rated luminous flux of the luminaire 50,700 lm 67,600 lm
Dimensions (L x W x H) 478 x 1053 x 108 mm 478 x 1407 x 108 mm
Terminals L, N, PE, max. 1 x 2.5 mm2 L, N, PE, max. 1 x 2.5 mm2
Photometric data
107,5
25,4
Polar curve wide-angle Polar curve narrow-angle 107,5
IHB16L . 64L LED IHB16L . 64L LED
25,4
694,9 10792,2
,5
(on request) 25,4
694,9 92,2
90 90 90 90 90 90 694,9 92,2
75 75
75 75 200 75 478,3
75 75
150 400
60 60 60
60
60
60 478,3
225 600
45
300
45 45
800
45
478,3
30 30 30 30
15 375 15 15 1000 15
C 0 0 0
C 0
C90 l/cd/klm C90 l/cd/klm
107,5 107,5
25,4drawing IHB24L LED
Dimension 25,4
Dimension drawing IHB64L LED
107,5 107,5
25,4
25,4
517 92,2 107,5
92,2
107,5 25,4 1407,8
25,4
517 92,2 1407,8 92,2
517 1407,8 92,2
478,3 92,2
478,3 478,3
478,3 478,3
478,3
Dimensions in mm
Dimension drawing IHB32L LED
107,5
25,4
107,5
25,4
694,9 92,2
107,5
25,4
694,9 92,2
694,9 92,2
478,3
478,3
478,3
107,5
25,4
14 Industrial LED Lighting catalogue CLS-CA455001EN - October 2015
107,5
25,4
1052.6 92,2
107,5
High-bay luminaires
IHB
Ordering details
Mounting accessories
CONTROLS
Champ® Pro PVM LED Series Luminaires are • Instant illumination and restrike
designed to provide full-spectrum, crisp, white • Dimmable by control input 0-10 V
light with custom IES Type I, III and V distribution.
• Wide temperature range from
Nine versions of the Champ Pro PVM LED are
-40 °C up to +65 °C (depends from Type)
available, providing ideal solutions for a wide range
of applications. • Redundancy in drivers with multiple series
circuits connected to each driver to avoid
complete loss of illumination
• Energy-efficient technology with up to 124 lm/W
- up to 77% energy savings over HID fixtures
• Contains no mercury or other hazardous
substances
• Shock and vibration resistant solid-state
luminaires have no filaments or glass
components that could break - greatly reduces
the risk of premature failure
Technical data
PVM 3L - 11L LED PVM 13L - 17L LED PVM 20L - 25L LED
Permissible ambient temperature -40 °C up to +65 °C -40 °C up to +55 °C -40 °C up to +55 °C
Lifetime fixtures 200,000 h at ta = +25 °C 170,000 h at ta = +25 °C 170,000 h at ta = +25 °C
60,000 h at ta = +65 °C 60,000 h at ta = +55 °C 60,000 h at ta = +55 °C
Rated voltage 100 - 277 V AC; 108 - 250 V DC 100 - 277 V AC; 108 - 250 V DC 100 - 277 V AC; 108 - 250 V DC
Frequency 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz
Power 1) 1) 1)
Power factor cos ϕ >0.9 >0.9 >0.9
Circuit Electronic driver Electronic driver Electronic driver
Protection class I I I
Lamp / Illuminant LED system, scope of delivery LED system, scope of delivery LED system, scope of delivery
Light colour/CRI 5000 K / Ra 70; 3000 K / Ra 80 on 5000 K / Ra 70; 3000 K / Ra 80 on 5000 K / Ra 70; 3000 K / Ra 80 on
request request request
Rated luminous flux of the luminaire 1) 1) 1)
Dimensions (L x W x H) 280 x 295 x 230 mm 381 x 381 x 197 mm 381 x 381 x 274 mm
Terminals L, N, PE, max. 1 x 2.5 mm2 L, N, PE, max. 1 x 2.5 mm2 L, N, PE, max. 1 x 2.5 mm2
dimmer, 2 x 2.5 mm2 max. dimmer, 2 x 2.5 mm2 max dimmer, 2 x 2.5 mm2 max
Enclosure colour Grey/black Grey/black Grey/black
Enclosure material Copper-free aluminium with Copper-free aluminium with Copper-free aluminium with
epoxy-powder coating epoxy-powder coating epoxy-powder coating
Weight 8.1 kg 16.3 kg 20.0 kg
Degree of protection accd. to EN 60529 IP66 IP66 IP66
Protective cover / protective bowl Heat- and impact resistant glass 2) Heat- and impact resistant glass 2) Heat- and impact resistant glass 2)
1) See Ordering details on page “Champ PVM” on page 19 2) Opaque cover and version in polycarbonate on request
Photometric data
Polar curve PVM LED type V Polar curve PVM LED type I Polar curve PVM LED type III
90 90 90 90 90 90 90 90 90 90 90
75 80 150 80
75 75 75 75 75
75 75 75 75 75 75
160 300 160
60 60 60 60 60 60
60 60 60 60 60 60
240 450 240
45 45 45 45
45 45 45 45
320 600 320
30 30 30 30 30 30
15 400 15 15 750 15 400
15 15
0 0
C 0 0
C 0
C 0 / C90 l/cd/klm C90 l/cd/klm C90 l/cd/klm
Dimensions
With top mounting module With top mounting module With top mounting module With top mounting module
JM5 PM5 CM20 TWM20
407 273,5
118,6
88,7
383
355
51,6
300
71,2
284
45
326
53,5
282
280
287
117,5
25° 248
226
Ø 280 Ø 381.5
Ø 381.5 1 1/2“NPT
Size 1 Size 2 Size 3
79.5
Mounting bracket S812
26.2
Mounting
bracket 52.3
Top for Locking pin
ceiling mounting
Dimensions in mm
LED module
Ordering details
Rated luminous
Lamp / flux of the Cable gland Screw Enclosure
Type Illuminant luminaire Weight / thread plug type Order No.
PVM LED Lamp module with LEDs (without top mounting module, please order separately)
PVM 3L LED LED System 29 W type V 3,515 lm 8.1 kg – – 1 1 2404 400
PVM 5L LED LED System 43 W type V 5,335 lm 8.1 kg – – 1 1 2407 746
PVM 7L LED LED System 55 W type V 7,260 lm 8.1 kg – – 1 1 2407 745
PVM 9L LED LED System 85 W type V 9,226 lm 8.1 kg – – 1 1 2409 889
Housing Size1
PVM 11L LED LED System 113 W type V 11,440 lm 8.1 kg – – 1 1 2408 233
PVM 13L LED LED System 130 W type V 13,266 lm 16.3 kg – – 2 1 2429 488
PVM 17L LED LED System 168 W type V 18,793 lm 16.3 kg – – 2 1 2430 349
PVM 21L LED LED System 196 W type V 22,110 lm 20.0 kg – – 3 1 2430 452
Housing Size 2 PVM 25L LED LED System 232 W type V 26,531 lm 20.0 kg – – 3 1 2430 455
PVM 3L LED LED System 29 W type I 3,360 lm 8.1 kg – – 1 1 2414 505
PVM 5L LED LED System 43 W type I 5,045 lm 8.1 kg – – 1 1 2414 517
PVM 7L LED LED System 55 W type I 6,844 lm 8.1 kg – – 1 1 2414 526
PVM 9L LED LED System 85 W type I 8,823 lm 8.1 kg – – 1 1 2414 534
Housing Size 3 PVM 11L LED LED System 113 W type I 10,730 lm 8.1 kg – – 1 1 2414 542
PVM 13L LED LED System 130 W type I 12,842 lm 16.3 kg – – 2 1 2430 347
PVM 17L LED LED System 168 W type I 18,195 lm 16.3 kg – – 2 1 2430 450
PVM 21L LED LED System 196 W type I 21,404 lm 20.0 kg – – 3 1 2430 453
PVM 25L LED LED System 232 W type I 25,685 lm 20.0 kg – – 3 1 2430 456
PVM 3L LED LED System 29 W type III 3,309 lm 8.1 kg – – 1 1 2414 508
PVM 5L LED LED System 43 W type III 4,468 lm 8.1 kg – – 1 1 2414 518
PVM 7L LED LED System 55 W type III 6,741 lm 8.1 kg – – 1 1 2407 564
PVM 9L LED LED System 85 W type III 8,618 lm 8.1 kg – – 1 1 2414 535
PVM 11L LED LED System 113 W type III 10,660 lm 8.1 kg – – 1 1 2414 543
PVM 13L LED LED System 130 W type III 12,493 lm 16.3 kg – – 2 1 2430 348
PVM 17L LED LED System 168 W type III 17,699 lm 16.3 kg – – 2 1 2430 451
PVM 21L LED LED System 196 W type III 20,822 lm 20.0 kg – – 3 1 2430 454
PVM 25L LED LED System 232 W type III 24,987 lm 20.0 kg – – 3 1 2430 457
PVM LED top mounting module, (without lamp module, please order separately)
JM5 1)
Top mounting module 1.6 kg 1 x 3/4'' – – 22 250
for 11/2“ pole mounting, 25° thread
PM5 Top mounting module 2.0 kg 1 x 3/4'' – – 00 080
for 11/2“ pole mounting, straight thread
CM20 Top mounting module 1.3 kg 4 x M20 4 x M20 – 1 1843 088
for M20 ceiling mounting thread
TWM20 Top mounting module 2.0 kg 4 x M20 4 x M20 – 1 1832 237
for M20 wall mounting thread
S812 Mounting bracket 1.0 kg – – – 1 2268 927
(can only be used with top mounting module
CM20)
1
) only for PVM 3L-11L
Scope of delivery without fixing accessories, if not stated otherwise. Metal cable glands see main catalogue part 2: 2.3.12 ff
Further mounting material on request
CONTROLS
Tufflite LED is a versatile general purpose, IP66 • Nominal 4’, 5’ and 6’ formats, in narrow and
rated, luminaire. It is supplied with fast fit mounting wide housings, ideal for both new and retro fit
clips for ease of installation avoids the need to drill applications
the housing. Options include; 3hour combined non- • Impact and heat resistant opal polycarbonate
maintained emergency functionality, dimmable diffuser and GRP base housing construction,
control gear and integrated lighting controls options IK08 rated, and secured with anti-tamper diffuser
to maximise energy savings, user comfort and clips
control. • Deep poured continuous polyurethane gasket to
Linear LED light engines and efficient control maintain IP66 rating
gear provide class leading performance; they are • Class leading LED luminaire performance and
protected by a GRP base and polycarbonate diffuser efficacy with lumen packages to match and
with a high impact resistance rating of IK08. exceed traditional fluorescent technology with
reduced energy consumption
With a comprehensive range of lumen outputs
across 3 luminaire lengths, Tufflite LED delivers • Integrated lighting control options to maximise
choice and flexibility to suit a wide range of energy saving, user comfort and control
applications such as warehousing, plant rooms, • Integral 3hr combined non-maintained
carparks, loading/storage spaces and assembly functionality option
areas where high ingress protection and robust • Fast fix stainless steel mounting clips for rapid
construction are required. installation. (No need to drill the housing avoiding
a potential ingress path)
• 20mm cable entry holes at each end, supplied complete with Photometric Data
sealing plugs Cat. No. TXL4N474KZ Utilisation factors / TM5
• Terminal block with 2x2.5mm² cable capacity per termination
Reflectances Room Index
C W F 0.75 1.0 1.25 1.5 2.0 2.5 3.0 4.0 5.0
• Through wiring kits available. 70 50 20 54 62 69 74 81 86 90 94 98
70 30 20 46 54 62 67 75 80 84 90 93
• Geartray hangs on the body for ease of install, locates in final
70 10 20 41 48 56 61 69 75 79 85 90
50 30 20 45 52 59 64 71 76 80 85 88
• Simple to use diffuser clips, 4 of which have security screws to
50 10 20 40 47 54 59 66 72 76 81 85
30 50 20 49 56 62 67 73 77 80 83 86
lock them in the closed position as an anti-tamper feature and
30 30 20 43 50 57 61 68 72 76 80 83
ensures access only through tooled entry to the luminaire. 30 10 20 39 46 52 57 64 69 72 77 81
Luminaire Output = 4738 lumens
0 0 0 36 42 48 53 59 63 67 71 74
• This luminaire is IP66 rated, this rating only applies when the SHR nom: 1.50
Catalogue numbers
Weight (kg)
For DALI dimming option, replace part number character Z with DD, e.g. TFP504KZ becomes TFP504KDD
Catalogue numbers
Emergency1 Range Housing Length4 Housing width4 Colour Temperature Control Gear
EL = TXL = Tufflite LED 4 = 4’ (1285mm) N = narrow (101mm) 4K = 4000oK Z = High Frequency Fixed Output
3hr Combined 5 = 5’ (1578mm) W = wide (145mm) DD = DALI Dimming
Non-maintained 6 = 6’ (1840mm)
Lumen Output5 Option6
Controls2,3 CO =
25 = 2500 55 = 5500
P = IP65 PIR only end mounted Corridor
27 = 2700 64 = 6400
D = IP65 PIR with Photocell end mounted Function
34 = 3400 65 = 6500
36 = 3600 75 = 7500
38 = 3800 78 = 7800
46 = 4600 90 = 9000
48 = 4800 95 = 9500
51 = 5100 112 = 11200
53 = 5300
1 Emergency versions use a dedicated LED which operates only when in emergency mode
2 The ‘P’ prefix sensor is a switching PIR only for use on fixed output control gear (unless inconjunction with DD and CO for Corridor Function)
The ‘D’ prefix sensor is a switching PIR with photocell, the control gear option dictates the sensor type i.e:
Switching with a threshold sensor for HF gear, DALI digital dimming gear uses a regulating photocell version
3 ‘P’ and ‘D’ prefix sensors are mounted in the end of the luminaire, they are IP20 rated and suitable for upto 5m mounting heights
4 Please refer to the dimension table and diagram for exact dimensions
5 The lumen output values are not all available in all lengths, please refer to HF catalogue listing
6 ‘Corridor Function’ is a Tridonic specific option available with their dimmable control gear, this ‘CO’ suffix must be added to ensure the correct
drives is used. Add the ‘CO’ after the DD suffix.
Luminaire example
Cat No Description
ELDTXL5W754KDD Tufflite LED 5’ 4000K, DALI, with integral combined non-maintained emergency functionality and fitted with end
mounted IP65 PIR/photocell DALI sensor
Single lamp rear quick fit bracket and tamper proof clip Twin lamp rear quick fit bracket and tamper proof clip
Catalogue numbers
Cat No Description Lumen Output (lm) Circuit Watts (W) Efficacy (Llm/cW)
Standard Fixed Output
TXL4N254KZ Tufflite LED 2500 4000K HF 1.2m single 2540 21.4 118.8
TXL4N344KZ Tufflite LED 3400 4000K HF 1.2m single 3433 29.9 115.0
TXL4N474KZ Tufflite LED 4700 4000K HF 1.2m single 4707 42.0 112.0
TXL4W644KZ Tufflite LED 6400 4000K HF 1.2m twin 6400 57.5 111.5
TXL5N274KZ Tufflite LED 2700 4000K HF 1.5m single 2792 22.6 123.6
TXL5N364KZ Tufflite LED 3600 4000K HF 1.5m single 3618 29.8 121.4
TXL5N514KZ Tufflite LED 4800 5100K HF 1.5m single 5154 45.0 114.7
TXL5W554KZ Tufflite LED 5500 4000K HF 1.5m twin 5514 44.6 123.6
TXL5W754KZ Tufflite LED 7500 4000K HF 1.5m twin 7518 63.3 118.8
TXL5W904KZ Tufflite LED 9000 4000K HF 1.5m twin 9033 79.2 114.1
TXL6N534KZ Tufflite LED 5300 4000K HF 1.8m single 5304 42.9 123.5
TXL6W954KZ Tufflite LED 9500 4000K HF 1.8m twin 9571 82.9 115.4
TXL6W1124KZ Tufflite LED 11200 4000K HF 1.8m twin 11200 100.7 111.2
For Emergency versions please add the EL prefix, e.g. TXL5N554KZ becomes ELTXL5N554KZ
For Emergency versions the circuit watts will increase by 1.5W to account for the charging circuit
For DALI dimmable options please replace the Z suffix with DD e.g. TXL5N554KZ becomes TXL5N554KDD
Refer to the Catalogue number matrix for other options
For further information contact our technical support and application department on 01302 303240 or email [email protected]
CONTROLS
The all new Crompack LED delivers a • Excellent light transmission and LED source
comprehensive range of linear LED luminaires obscurity from the reeded opal diffuser
incorporating a range of lumen outputs across 3 • Nominal 4’, 5’ and 6’ length formats, ideal for
luminaire lengths. Options include dimmable control both new installations and retro fit applications
gear and a range of integrated controls options to
• The range offers luminaire lumen outputs of up
maximise energy savings.
to 10500lm delivering high efficacies of up to
Available with 3 hour combined non-maintained 133Llm/cW
emergency functionality delivering excellent spacing • High efficiency LED strip technology and driver
and uniformity. combinations, with purpose designed optics and
The simple 2 part housing facilitates quick and thermal management, maximise the LED and
control gear life and performance
simple installation, a first fix plate allows mechanical
mounting and electrical connections to be made, the • Long LED life and no lamps to change
optic unit then connects on a plug and socket and significantly reduce maintenance costs,
snap fits to the base, with 2 retained screws adding particularly in 24/7 operations and inaccessible
additional integrity to the installation ensuring tooled areas
access only. • Integrated controls options providing occupancy
detection and daylight harvesting to maximise
Optical control and performance generate high
energy saving, user comfort and control
efficacies and deliver ECA compliance.
• Integral 3hr combined non-maintained
functionality variants
• First fix base and plug and socket housing
connection for rapid installation
CONTROLS
Catalogue numbers
Emergency1 Range Length5 Lumen Output6 Colour Temperature Control Gear Option7
EL = CXL = Crompack LED 4 = 4’ 25 = 2500 4K = 4000oK Z = High Frequency Fixed Output CO =
3hr Combined 5 = 5’ 30 = 3000 DD = DALI Dimming Corridor
Non-maintained Controls2,3,4 6 = 6’ 40 = 4000 Function
ISM = Mini Sensor 45 = 4500
P = IP20 PIR Only End Mounted 50 = 5000
D = IP20 PIR with Photocell 55 = 5500
IM = Microwave Occupancy Sensor 60 = 6000
65 = 6500
70 = 7000
75 = 7500
85 = 8500
100 = 10000
1 Emergency versions use a dedicated LED which operates only when in emergency mode
2 The ‘P’ prefix sensor is a switching PIR only for use on fixed output control gear (unless inconjunction with DD and CO for Corridor Function)
The ‘D’ prefix sensor is a switching PIR with photocell, the control gear option dictates the sensor type i.e:
Switching with a threshold sensor for HF gear, DALI digital dimming gear uses a regulating photocell version
3 ‘P’ and ‘D’ prefix sensors are mounted in the end of the luminaire and suitable for upto 5m mounting heights
4 ISM mini head sensor for use with DALI control gear only, also suits BUS Loop Communication - see Lighting Solution Controls page 457
5 The length character gives the generic luminaire length, please refer to the dimension table for exact dimensions
6 The lumen output values are not all available in all lengths, please refer to HF catalogue listing
7 ‘Corridor Function’ is a Tridonic specific option available with their dimmable control gear, this ‘CO’ suffix must be added to ensure the correct
drives is used. Add the ‘CO’ after the DD suffix.
Luminaire example
Cat No Description
ELISMCXL5454KDD Crompack LED 5’ 4500lm, 4000K, DALI with integral mini sensor and integral 3hr combined non-maintained emergency functionality
First fix backplate with optical unit suspended on safety cords Rapid fit plug and socket
End mounted PIR/photocell Lighting control sensor and integral emergency LED
Catalogue numbers
Cat No Description Lumen Output (lm) Circuit Watts (W) Efficacy (Llm/cW)
Standard Fixed Output
CXL4254KZ Crompack LED 2500 4000K HF 1.2m 2550 22.1 115.4
CXL4304KZ Crompack LED 3000 4000K HF 1.2m 3050 28.1 108.5
CXL4404KZ Crompack LED 4000 4000K HF 1.2m 3900 36.6 106.6
CXL4454KZ Crompack LED 4500 4000K HF 1.2m 4500 44.2 101.8
CXL4504KZ Crompack LED 5000 4000K HF 1.2m 5000 43.4 115.2
CXL4604KZ Crompack LED 6000 4000K HF 1.2m 5950 57.5 103.5
CXL4704KZ Crompack LED 7000 4000K HF 1.2m 6900 70.4 98.0
ELCXL5404KZ Crompack LED 4000 4000K HF 1.5m Emergency 4000 32.9 121.6
ELCXL5454KZ Crompack LED 4500 4000K HF 1.5m Emergency 4300 36.9 116.5
ELCXL5504KZ Crompack LED 5000 4000K HF 1.5m Emergency 5100 44.3 115.1
ELCXL5604KZ Crompack LED 6000 4000K HF 1.5m Emergency 6000 56.7 105.8
ELCXL5704KZ Crompack LED 7000 4000K HF 1.5m Emergency 7200 72.3 99.6
ELCXL6554KZ Crompack LED 5500 4000K HF 1.8m Emergency 5700 54.2 105.2
ELCXL6654KZ Crompack LED 6500 4000K HF 1.8m Emergency 6400 63.3 101.1
ELCXL6754KZ Crompack LED 7500 4000K HF 1.8m Emergency 7400 70.3 99.6
ELCXL6854KZ Crompack LED 8500 4000K HF 1.8m Emergency 8500 82.5 103.0
ELCXL61004KZ Crompack LED 10000 4000K HF 1.8m Emergency 10300 107.6 95.7
For DALI dimming option, replace part number character Z with DD, eg. CXL5454KZ becomes CXL5454KDD
For further information contact our technical support and application department on 01302 303240 or email [email protected]
Weight
Cat No Description (kg)
SWKITP15SY Suspension Wire Kit, 1.5m, Short Yoke (Pair) 0.1
CONTROLS
For a wide range of applications where flexibility • Polycarbonate lens and ABS body for durability
needs to be married to performance, the Caius range • TPa material means compliance with the
offers a complete solution. Caius combines practical requirements for escape routes
attributes with contemporary clean lines and form.
• Opal diffuse lens for homogenous light output
Although at home in most interior applications, Caius
offers ingress protection to IP65 so suits a wide • Choice of two complimentary body sizes
range of locations. Caius gives a highly efficient • Fully integral emergency versions
design solution, minimising installation points. • Microwave option
High output LED sets offer high levels of efficacy • Corridor control function option (DALI/ DSI
combined with class leading emergency operation version)
helping to reduce the number of installed points • IP65 dust tight and water jet proof
whilst maintaining compliant lighting designs.
• Balanced looks maximize the efficiency and
output of Caius
• Installation friendly design reduces on site costs
Photometric Data
Materials
Cat. No. CBHS174KZ
Utilisation factors / TM5
• Body – ABS structurally strong and impact resistant
Reflectances Room Index
• Lens – TPa Polycarbonate opal C W F 0.75 1.0 1.25 1.5 2.0 2.5 3.0 4.0 5.0
70 50 20 56 64 71 77 84 88 92 96 100
70 30 20 49 56 64 69 77 82 86 92 95
Installation notes 70 10 20 43 51 58 64 71 77 82 88 92
50 50 20 54 62 68 73 80 84 87 92 94
• Terminal block with a 2 x 2.5mm2 cable capacity per
50 30 20 47 55 62 67 74 79 83 88 91
termination 50 10 20 42 50 57 62 69 75 79 84 88
30 50 20 52 59 66 70 76 80 83 87 90
30 30 20 46 53 60 65 71 76 79 84 87
Options LO1707lm
20W
30 10 20 42 49 55 60 67 72 76 81 84
0 0 0 39 46 52 57 63 68 71 76 79
• Fully integrated LED emergency conversion, 3 hour duration
BZ –class 5 5 5 5 5 5 5 5 5
legislative test requirements and increase the lifespan of your
50 50 20 54 62 68 73 80 84 87 92 94
50 30 20 47 55 62 67 74 79 83 88 91
lighting equipment
50 10 20 42 49 57 62 69 75 79 84 88
30 50 20 52 59 66 70 76 80 83 87 90
30 30 20 46 53 60 65 71 76 79 84 87
LO2388lm 30 10 20 42 49 55 60 67 72 76 81 85
28W 0 0 0 39 46 52 57 63 68 71 76 79
BZ –class 5 5 5 5 5 5 5 5 5
Dimensions
Corridor function
Caius is available with a DALI/ DSI corridor function option for applications where comfort, wayfinding and safety are considerations.
Typically used in transit areas, corridor function allows the safe passage of people by utilizing local detection to switch products on
rapidly either adjacent to detection, or in some cases ahead of the direction of movement. Caius can be used to trigger this by means of
the optional built in Microwave detector or by linking to remotely mounted devices.
Operation
Catalogue numbers
Variant Cat No Lumen Output Wattage (W) Llm/ cW Weight (kg) Em Cat No Weight (kg)
Small CBHS174KZ 1707 20 85.3 1.3 ELCBHS174KZ 2.2
Large CBHL234KZ 2388 28 85.2 1.9 ELCBHL234KZ 2.8
For DALI Dimming option replace character Z with DD, e.g. CBHS174KZ becomes CBHS174KDD
Emergency versions also available with automatic test functionality, e.g. EasiCheck 2
For corridor function, add the suffix CO, e.g. CBHS174KDD becomes CBHS174KDDCO
Note - corridor function is only available as an option on DALI products, not on HF variants
Champ® Pro PFM/NPFM Series Floodlights are • Instant illumination and restrike
designed to provide full-spectrum, crisp, white light. • Wide temperature range from
Eight versions of the Champ PFM/NPFM LED are -40 °C up to +65 °C (depending on model)
available, providing ideal solutions for a wide range
• Redundancy in drivers with multiple series
of applications.
circuits connected to each driver to avoid
complete loss of illumination
• Energy-efficient technology with up to 112 lm/W
- up to 65 % energy savings over HID fixtures
• Contains no mercury or other hazardous
substances
• Shock- and vibration-resistant solid-state
luminaires have no filaments or glass
components that could break - greatly reduces
the risk of premature failure
Technical data
Cable gland / gland plates / enclosure Thread 2 x M20 x 1.5, 1 x M20 2 x M20 x 1.5, 1 x M20 plugged, or 2 x M20 x 1.5, 1 x M20 plugged, or
drilling plugged, or
2 x M25 x 1.5, 1 x M25 plugged 1) 2 x M25 x 1.5, 1 x M25 plugged 1)
thread 2 x M25 x 1.5, 1 x M25
plugged 1)
Type of mounting Mounting bracket Mounting bracket Mounting bracket
Degree of protection accd. to EN 60529 IP66 IP66 IP66
Protective cover / protective bowl Borosilicate glass 2) Borosilicate glass 2) Borosilicate glass 2)
1
) see ordering details 2
) Opaque cover and cover in polycarbonate on request
Photometric data
90 90 90 90 90 90
75 100 100
75 75 75
75 75
200 200
60 60 60 60
60 60
300 300
45 45 45 45
400 400
30 30 30 30
15 500 15 500
15 15
C 0 0 0
C 0
C90 l/cd/klm C90 l/cd
Dimensions
Ø14
305
121 Ø14
127
449
NPFM 25L
552.5
277
556.3 235.8
533 203.7
120.7 Ø14 277
533 234.5
203.7
406
825
632.6
Dimensions in mm
Weight and dimensions
PFM 3L bis PFM 7L
Dimensions (L x W x H) 394 x 178 x 305 mm
Weight 13.9 kg
PFM 9L bis PFM 13L
Dimensions (L x W x H) 394 x 178 x 305 mm
Weight 14.4 kg
NPFM 25L
Dimensions (L x W x H) 533 x 204 x 406 mm
Weight 23.6 kg
NPFM 50L
Dimensions (L x W x H) 553 x 204 x 825 mm
Weight 48.1 kg
Ordering details
Rated luminous
Lamp / flux of the Screw
Type illuminant luminaire Cable gland/thread plug Order No.
PFM 3L - 13L LED
PFM 3L CY/UNV1 76 M20 LED system 28 W 1) 3,189 lm 2 x M20, metal thread 1 x M20 1 2565 533
PFM 5L CY/UNV1 76 M20 LED system 45 W ) 1
5,183 lm 2 x M20, metal thread 1 x M20 1 2565 534
PFM 7L CY/UNV1 76 M20 LED system 62 W 1) 7,095 lm 2 x M20, metal thread 1 x M20 1 2565 536
PFM 9L CY/UNV1 76 M20 LED system 79 W ) 1
9,132 lm 2 x M20, metal thread 1 x M20 1 2565 537
PFM 11L CY/UNV1 76 M20 LED system 99 W 1) 11,107 lm 2 x M20, metal thread 1 x M20 1 2565 538
PFM 13L CY/UNV1 76 M20 LED system 112 W 1) 13,100 lm 2 x M20, metal thread 1 x M20 1 2565 539
PFM 3L CY/UNV1 76 M25 LED system 28 W ) 1
3,189 lm 2 x M25, metal thread 1 x M25 1 2565 540
PFM 5L CY/UNV1 76 M25 LED system 45 W 1) 5,183 lm 2 x M25, metal thread 1 x M25 1 2565 541
PFM 7L CY/UNV1 76 M25 LED system 62 W ) 1
7,095 lm 2 x M25, metal thread 1 x M25 1 2565 542
PFM 9L CY/UNV1 76 M25 LED system 79 W 1) 9,132 lm 2 x M25, metal thread 1 x M25 1 2565 543
PFM 11L CY/UNV1 76 M25 LED system 99 W 1) 11,107 lm 2 x M25, metal thread 1 x M25 1 2565 544
PFM 13L CY/UNV1 76 M25 LED system 112 W ) 1
13,100 lm 2 x M25, metal thread 1 x M25 1 2564 387
NPFM 25L
NPFM 25L CY/UNV1 76 LED system 263 W 1) 26,240 lm 2 x M25, metal thread, 1 x M25 1 2433 691
M25 1 x M25 cable gland
Ø 10 - 16 mm
NPFM 50L
NPFM 50L CY/UNV1 76 LED system 531 W 1) 53,890 lm 2 x M25, metal thread, 1 x M25 1 2442 808
M25 1 x M25 cable gland
Ø 10 - 16 mm
1) Scope of delivery
Accessories
The Gladiator LED luminaire offers an energy saving • Low energy LED solution, 39% less energy
alternative to traditional light sources for amenity consumed than typical 42W CFL equivalent
area and perimeter lighting applications. The twin product
multi-die LED arrays deliver a long 50,000 hour life • Long, 50,000 hour LED life to L70, typically
and eliminate the need for lamp changes, minimising 10-12 years commercial operation with no lamp
through life operating and maintenance costs, saving changes can dramatically reduce maintenance
39% in energy over an equivalent 42W CFL variant. costs
The provision for automatic dusk to dawn operation • Robust, die cast aluminium base with conduit
via an optional photocell variant allows automatic entries provides rigid base ideal on uneven walls
security lighting whilst avoiding wasted energy
• Attractive, curved profile, polycarbonate diffuser
during daylight hours.
has high impact resistance, ideal for public
The robust cast aluminium base and polycarbonate spaces and commercial applications
lens offer good impact resistance ideally suited to • IP65 rated, dust tight and jet proof housing
commercial applications. Installation is made easy construction, ideal for exterior use and ease of
with integrated features such as the side mount cleaning
cable gland or rear BESA cable entry options. • Photocell option for dusk ‘til dawn operation
enables automatic safety/security illumination
whilst preventing wasted energy during daylight
hours
• The LED solution offers the benefit of instant
white light, no run up delay and good visual
acuity over HID lamp options
Materials
• Base - pressure die cast aluminium black finish
• Lens / cover - polycarbonate, self coloured black cover and
clear prismatic optic section
Installation notes
308
• Suitable for wall mounting
• BESA entry features on back plate
• 20mm conduit entry on both sides for through wiring 264
termination
• Hinged diffuser secured by captive screws
Specification
To specify state: Robust wall mounted LED area lighting luminaire,
dust tight and water jet proof to IP65, with die cast aluminium
base and polycarbonate lens / cover assembly including clear
prismatic refractor and optional photocell as Eaton’s Gladiator LED
range, part no. ___________
Catalogue numbers
Lamp Rating Cat No Weight (kg)
2 x 13W LED GLR-2L-CW 1.7
2 x 13W LED GLR-2L-CWPC 1.8
Emergency
2 x 13W LED EBGLR-2L-CW 2.1
2 x 13W LED EBGLR-2L-CWPC 2.2
Galaxy LED is a low energy solution to a varied range • High efficacy LED
of applications. High efficiency is a key part of its • Die-cast aluminium construction for a long
appeal and with a wide range of outputs, is ideal in a durable life
multitude of applications.
• IP65 dust tight and water jet proof for stay clean
Galaxy LED is rated to IP65, dust tight and low operation
pressure water jet proof, with a robust die-cast • Inbuilt inclinometer aids aim and set up
aluminium body.
• Outstanding optical performance reduces
installed points
• Supplied with three core 1m flying lead
• 10W and 30W versions are available with
integrated PIR as an option
Materials
Installation notes
• Suitable for column, wall and floor mounting
• Stirrup bolts directly to vertical surface for area floodlighting
or to floor for façade lighting
• 3 way
• Aimed by slackening side bolts and positioning angle using
inclinometer on stirrup
• Front lens secured by latching clip
• Supplied complete with 1m 3 core 1mm2 lead
Specification
To specify state: Die cast aluminium floodlight, with symmetrical
Galaxy LED with PIR Sensor
reflector and toughened safety glass. Finished in black paint finish
and dust tight and water jet proof to IP65, as Eaton’s Galaxy LED
range, part no. ___________
Dimensions
D
C E
A B C D E
Catalogue numbers
Part No With PIR Lumen Output Wattage Llm/cW Weight (kg) Weight + PIR (kg)
GLL105KZ GLL105KZPIR 838 11.85 70.70 1.10 1.22
GLL305KZ GLL305KZPIR 2655 32.80 81.30 2.97 2.99
GLL505KZ - 4410 51.50 85.50 5.21 -
GLL1005KZ - 7817 101.40 77.10 7.32 -
GLL2005KZ - 17495 220.00 79.30 14.08 -
LED Flood presents the market with a high • Long, 50,000+ hour LED life to L70, typically
performance revelation in exterior LED area lighting. 10-12 years commercial operation with no lamp
changes can dramatically reduce maintenance
Up to five cool white 5000°K LED arrays are
costs
integrated into the robust die-cast aluminium
housing, with the purpose designed reflector • Robust, die-cast aluminium base with adjustable
delivering a range of lumen packages to suit the fixing bracket to suit wall or column mount
application. The thermal mass and design of the installations
housing provides excellent thermal management • IP65 rated construction, ideal for exterior use
in conjunction with the appropriate drive current to and ease of cleaning
maximise LED output and ensure a long operational
life with minimal maintenance and eliminating the
need for lamp changes.
LEDs also provide the benefit of instant white
light with no restrike delay and reduced consumed
energy over traditional HID lamps.
Installation notes
horizontal surfaces and column mounting Cat. No. LFL5-3LR1Z Cat. No. LFL5-3LR1Z mounted at 8m
(m)
20 10
15
15
451mm
451mm 10
5
0
20 15 10 5 0 5 10 15 20
(m)
50mm
50mm CLCL
17mm
17mm
CLCL
4 4x x11mm
11mm
=60mm=
=60mm=
=120mm=
=120mm=
=406mm=
=406mm=
502mm
502mm
178mm
178mm
213mm
213mm
115mm
115mm 433mm
433mm
Catalogue numbers
Notes
1 All standard luminaires are IP65 rated with close coupled gear box
2 Dimmable options to special order
• Remote gear box to special order
• Photocell option to special order
Lumen Maintenance
TM-21 Lumen
Ambient Maintenance Theoretical L70
Temperature (60,000 Hours) (Hours)
25°C > 94% > 350,000
40°C > 93% > 250,000
50°C > 90% > 170,000
Dimensions
1, 2 or 3 Light Squares
22" [559mm]
Optical distributions
The Navion luminaire has a choice of seven asymmetric area, three asymmetric roadway, three symmetric and three specialized
distributions.
Specialized Distributions
AFL SLL SLR
(Automotive Frontline) (90° Spill Light Eliminator Left) (90° Spill Light Eliminator Right)
Finish
Five-stage super TGIC paint resists extreme weather conditions while providing optimal color and gloss retention. It’s available in
standard grey or optional bronze, black, dark platinum, graphite metallic or white.
Optional features
Catalogue numbers
Add ‘-CE’ suffix to order CE marked versions. Sample number: NAV-AE-01-E-UNV-T3-10K-AI-AP-CE
Number
Product of Light
Family 1 Light Engine Squares 2 Driver Voltage Distribution Surge Protection
NAV=Navion AE=1A Drive 01=1 E=Non- UNV=Universal T2=Type II SLR= 90° Spill Light Eliminator 10K=Cooper 10kV Surge
Current 02=2 Dimming 120-277V T2R=Type II Roadway Right Module (Standard)
D=Dimming 347=347V T3=Type III RW=Rectangular Wide Type I X=Driver Surge Protection Only 4
03=3 AFL=Automotive Front Line
480=480V 3 T3R=Type III Roadway
04=4 SL2=Type II w/Spill Control
T4FT=Type IV Forward Throw
06=6 T4W=Type IV Wide SL3=Type III w/Spill Control
5NQ=Type V Narrow SL4=Type IV w/Spill Control
5MQ=T ype V Square Medium SLL=90° Spill Light Eliminator Left
5WQ=Type V Square Wide SLR=90° Spill Light Eliminator
Right
SL2=Type II w/Spill Control
RW=Rectangular Wide Type I
SL3=Type III w/Spill Control
AFL=Automotive Frontline
SL4=Type IV w/Spill Control
SLL= 90° Spill Light Eliminator
Left
OA1223=10kV Surge Module Replacement MA1011-XX=2@180° Tenon Adapter for 3-1/2” O.D. Tenon MA1018-XX=2@180° Tenon Adapter for 2-3/8” O.D. Tenon
OA/RA1013=Photocontrol Shorting Cap MA1012-XX=3@120° Tenon Adaptor for 3-1/2” O.D. Tenon MA1019-XX=3@120° Tenon Adapter for 2-3/8” O.D. Tenon
OA/RA1014=NEMA Photocontrol - 120V MA1013-XX=4@90° Tenon Adapter for 3-1/2” O.D. Tenon MA1045-XX=4@90° Tenon Adapter for 2-3/8” O.D. Tenon
OA/RA1016= NEMA Photocontrol - Multi-Tap MA1014-XX=2@90° Tenon Adapter for 3-1/2” O.D. Tenon MA1048-XX=2@90° Tenon Adapter for 2-3/8” O.D. Tenon
OA/RA1027= NEMA Photocontrol - 480V MA1015-XX=2@120° Tenon Adapter for 3-1/2” O.D. Tenon MA1049-XX=3@90° Tenon Adapter for 2-3/8” O.D. Tenon
OA/RA1201=NEMA Photocontrol - 347V MA1016-XX=3@90° Tenon Adapter for 3-1/2” O.D. Tenon FSIR-100=Wireless Confi guration Tool for Motion Sensor 16
MA1010-XX=Single Tenon Adapter for 3-1/2” O.D. Tenon MA1017-XX=Single Tenon Adapter for 2-3/8” O.D. Tenon LS/HSS=Field Installed House Side Shield 17
A15=15” Straight Arm 18
Notes:
1. DesignLights ConsortiumTM Qualifi ed. Refer to www.designlights.org Qualifi ed Products List under Family Models for details.
2. Standard 4000K CCT and minimum 70 CRI.
3. Only for use with 480V Wye systems. Per NEC, not for use with ungrounded systems, impedance grounded systems or corner grounded systems (commonly known as Three
Phase Three Wire Delta, Three Phase High Leg Delta and Three Phase Corner Grounded Delta systems).
4. Consult factory for driver surge protection values.
5. Low-level output varies by number of light squares specifi ed. Consult factory. 2L is not available with MS/X, MS/DIM, DIMRF-LW or DIMRF-LN in combination with 347V or 480V.
2L is available in 4 and 6 light square
confi gurations. No terminal block with 2L options.
6. Use dedicated IES fi les for 3000K and 6000K when performing layouts. These fi les are published on the Navion luminaire product page on the website.
7. 1 Amp standard. Use dedicated IES fi les for 530mA and 700mA when performing layouts. These fi les are published on the Navion luminaire product page on the website.
8. Only available with dimming driver.
9. CE is not available with the DIMRF, MS, MS/X, MS/DIM, PER or PER7 options. Available in 120-277V only.
10. Sensor mounted externally. Must specify dimming driver. Consult factory for more information.
11. Sensor mounted externally. Available in 4 or 6 light square confi gurations. Replace “X” with number of squares in low output mode. For ON/OFF operation, replace “X” with “0”.
Maximum two squares in low output mode. Not available with dimming driver. No terminal block with ON/OFF sensor.
12. 22” upsweep arm. Round pole adapter and mounting hardware included, “M” drill pattern.
13. Round pole adapter and mounting hardware included, “M” drill pattern.
14. Only for use with SL2, SL3, SL4 and AFL distributions. The light square trim plate is painted black when the HSS option is selected.
15. LumaWatt wireless sensors are factory installed only requiring network components RF-EM-1, RF-GW-1 and RF-ROUT-1 in appropriate quantities. See www.eaton.com/lighting for
LumaWatt application information.
Not available with PER7, PER, FADC or 2L options.
16. This tool enables adjustment of parameters including high and low modes, sensitivity, time delay, cutoff and more. Consult your lighting representative at Eaton for more
information.
17. One required for each light square.
18. Replace XX with paint color.
CONTROLS
The GalleonTM LED luminaire delivers a new level of • Choice of 16 high-efficiency, patented AccuLED
performance and versatility for commercial area, site Optics™
and roadway applications. Incorporating industry- • L90, 60,000 hours at 40°C (per IESNA TM-21)
leading, patented optics, the Galleon LED luminaire
• Standard in 4000K CCT and min 70 CRI, optional
offers a choice of 16 specialized optical distributions
3000K and 6000K
that deliver superior control and maximize light
levels. • 40°C to 40°C operating range, optional 50°C high
ambient
With a choice of 30 lumen packages, the Galleon
• 120-277V 50/60Hz, 347V 60Hz or 480V 60Hz
LED luminaire allows scalability from 3,000 to over
operation
53,000 delivered lumens. The 4000K/70 CRI is
standard, with 6000K/70 CRI and 3000K/70 CRI • IP66 rated housing and LED light squares
options available. • 3G vibration rated
In addition to delivering superior performance, • Pole, mast-arm or wall-mounted configurations
the Galleon LED luminaire is designed for low • Five-year warranty
maintenance, long life and low cost of ownership.
The LED components and fixture housing are IP66
rated, which provides years of reliable operation with
minimal service requirements.
Lumen Maintenance
TM-21 Lumen
Ambient Maintenance Theoretical L70
1 - 4 Light Squares 5 - 6 Light Squares
Temperature (60,000 Hours) (Hours)
25°C > 94% > 350,000
40°C > 93% > 250,000
50°C > 90% > 170,000
Optical distributions
The Galleon LED luminaire has a choice of seven asymmetric area, three asymmetric roadway, three symmetric and three specialized
distributions.
Specialized Distributions
AFL SLL SLR
(Automotive Frontline) (90° Spill Light Eliminator Left) (90° Spill Light Eliminator Right)
Triple2 2 @ 120°
NOTES: 1. Round poles are 3 @ 120°. Square poles are 3 @ 90°. 2. Round poles are 3 @ 90°.
Catalogue numbers
Number
of Light
Product Family 1
Light Engine Squares 2 Lamp Type Voltage Distribution Color Mounting
GLEON=Galleon AE=1A Drive 01=1 LED=Solid State E1=120-277V T2=Type II AP=Grey [Blank]=Arm for Round or
Current 02=2 Light 347=347V 3 T2R=Type II Roadway BZ=Bronze Square Pole
03=3 Emitting 480=480V 3, 4 T3=Type III BK=Black EA=Extended Arm 5
04=4 Diodes T3R=Type III Roadway DP=Dark Platinum MA=Mast Arm Adapter 6
05=5 T4FT=Type IV Forward Throw GM=Graphite Metallic WM=Wall Mount
06=6 T4W=Type IV Wide WH=White
07=7 5NQ=Type V Narrow
08=8 5MQ=Type V Square Medium
09=9 5WQ=Type V Square Wide
10=10 SL2=Type II w/Spill Control
SL3=Type III w/Spill Control
SL4=Type IV w/Spill Control
SLL=90° Spill Light Eliminator
Left SLR=90° Spill Light
Eliminator Right
RW=Rectangular Wide Type I
AFL=Automotive Frontline
1. DesignLights ConsortiumTM Qualifi ed. Refer to www.designlights.org Qualifi ed Products List under Family Models for details.
2. Standard 4000K CCT and minimum 70 CRI.
3. Requires the use of a step down transformer when combined with MS/DIM, MS/X or DIMRF.
4. Only for use with 480V Wye systems. Per NEC, not for use with ungrounded systems, impedance grounded systems or corner grounded systems (commonly known as Three Phase
Three Wire Delta, Three Phase High Leg Delta and Three Phase Corner Grounded Delta systems).
5. May be required when two or more luminaires are oriented on a 90° or 120° drilling pattern. Refer to arm mounting requirement table.
6. Factory installed.
7. 2L is not available with MS, MS/X or MS/DIM at 347V or 480V. 2L in AE-02 through AE-04 requires a larger housing, normally used for AE-05 or AE-06. Extended arm option may be
required when mounting two or more fi xtures per pole at 90° or 120°. Refer to arm mounting requirement table.
8. Not available with LumaWatt wireless sensors.
9. Extended lead times apply. Use dedicated IES fi les for 3000K and 6000K when performing layouts. These fi les are published on the Galleon luminaire product page on the website.
10. Extended lead times apply. For 8030, factor 7030 IES fi les x .92 (8% lumen loss). For 7050, use 7060 IES fi les.
11. 1 Amp standard. Use dedicated IES fi les for 530mA and 700mA when performing layouts. These fi les are published on the Galleon luminaire product page on the website.
12. 50°C lumen maintenance data applies to 530mA and 700mA drive currents.
13. Consult factory for more information.
14. Utilizes internal step down transformer when 347V or 480V is selected.
15. The FSIR-100 confi guration tool is required to adjust parameters including high and low modes, sensitivity, time delay, cutoff and more. Consult your lighting representative at Eaton for
more information.
16. Not available with HA option.
17. Approximately 22’ detection diameter at 8’ mounting height.
18. Approximately 40’ detection diameter at 20’ mounting height.
19. Approximately 60’ detection diameter at 40’ mounting height.
20. Approximately 100’ detection diameter at 40’ mounting height.
21. Replace X with number of Light Squares operating in low output mode.
22. LumaWatt wireless sensors are factory installed only requiring network components RF-EM-1, RF-GW-1 and RF-ROUT-1 in appropriate quantities. See www.eaton.com/lighting for
LumaWatt application information.
23. Not available with house side shield (HSS).
24. Only for use with SL2, SL3, SL4 and AFL distributions. The Light Square trim plate is painted black when the HSS option is selected.
25. CE is not available with the DIMRF, MS, MS/X, MS/DIM, P, R or PER7 options. Available in 120-277V only.
26. This tool enables adjustment of parameters including high and low modes, sensitivity, time delay, cutoff and more. Consult your lighting representative at Eaton for more information
27. One required for each Light Square.
CONTROLS
Options
• Maintained and non-maintained operation, 3 hour duration
• EasiCheck addressable testing (Fluorescent only)
Options L (mm) W (mm) D1 (mm) D2 (mm) Cut out (mm)
• Central system slave versions (Fluorescent only) Surface mounted 390 110 90 - -
Semi-recessed 430 150 27 63 380 x 102
• Semi-recessing trim plate accessory
• Matching mains only version (1x11W TC-S compact
fluorescent) 18 metres
Specification
Self contained - To specify state: BSI Kitemarked and ICEL
registered, IP65 vandal resistant self-contained emergency
luminaire, die cast aluminium base with BESA drill-out, 2 x conduit
entries with blanking plugs, hinged geartray with plug and socket
terminal block and tamper resistant opal diffuser, as AG Bulkhead
range, part no. ___________
Self-test/Slave - To specify state: Intelligent self-testing/Central
system compatible slave, IP65 vandal resistant emergency Catalogue numbers
luminaire, die cast aluminium base with BESA drill-out, 2 x conduit
Weight
entries with blanking plugs, hinged geartray with plug and socket System Mode Cat No (kg)
terminal block and tamper resistant opal diffuser, as AG Bulkhead
range, part no. ___________ Non Maintained 3Hr AG83ICEL 1.8
Non Maintained 3Hr EasiCheck AG83EC 1.8
Non Maintained 3Hr EasiCheck 2 AG83EC2 1.8
Accessories Maintained 3Hr AG83MICEL 1.9
Weight
Description Cat No (kg) Maintained 3Hr EasiCheck AG83MEC 1.9
Legend Kit Maintained 3Hr EasiCheck 2 AG83MEC2 1.9
European Format Self-Adhesive Legend Kit LEXSAM 0.05 230V CeaGuard Slave AG8230CG 0.9
ISO7010 Format Self-Adhesive Legend Kit LEXSAM-ISO 0.05 230V AC Mains Slave AG8230 1.5
230V AC Mains Slave EasiCheck AG8230EC 1.6
Trim plate 50V AC/DC Central System Slave AG850 1.5
Semi-recess plate AG8FM 0.1 110V AC/DC Central System Slave AG8110 1.5
Mains Only 230V (non emergency 11W PL) AG1111 0.9
LED
Maintained/ Non maintained 3Hr AGL3M 1.5
i-P65 is a high specification competitively priced • Versatile multi-functional use (escape, open area
emergency LED bulkhead utilising the latest LED and exit sign use)
and optic technology to provide an attractive, good • Low power consumption reducing cost of
quality, functional luminaire for indoor and outdoor ownership
use. Boasting numerous features and benefits, the
• Ease of installation, reducing installation time
i-P65 can be used to provide escape route lighting,
and cost
single sided exit sign or optional double sided exit
sign with a common look and feel where aesthetics • Excellent spacing reducing the quantity of
fittings required
are a primary concern.
• 60,000 hour life LED for reduced maintenance
The i-P65 has been designed for ease of installation,
reduced power consumption, minimal maintenance, • Self-contained, slave, self-test and addressable
reducing the TCO (total cost of ownership) with a testing options
compact attractive appearance. The innovative optic
design used in the i-P65, developed and produced by
Eaton, efficiently utilises light from the LED source
to provide uniform lighting distribution. For both
escape route and open area anti-panic emergency
lighting applications, performance is improved and
electrical power consumption is reduced.
• 2 x High power 1W white LED Cat. No. IP65LEDE Cat. No. IP65LEDO
Escape Route Open Area Anti-Panic
• Consumption (Maintained) - 6.9VA/5W 105° 105° 105° 105°
Materials
60° 60° 60° 300 60°
2000 450
600
30° I ( cd ) 30°
• Battery - NiMh 4 cell (self contained version)
30° I ( cd ) 30°
C0 C0
Installation notes Viv Byrne Cooper Lighting and Safety, Wheatley Hall Road
Viv Byrne Cooper Lighting and Safety, Wheatley Hall Road
Wilmersdorfer Str 39 • D-10627 Berlin • Tel +49 30 751 70 07 • FAX +49 30 751 01 27 page 1 / 1
Wilmersdorfer Str 39 • D-10627 Berlin • Tel +49 30 751 70 07 • FAX +49 30 751 01 27 page 1 / 1
• Suitable for ceiling or wall surface mount Mode Mounting Lux level
height directly
• Outboard fixings for improved IP integrity (m) under
Escape optic (Asymmetric) Escape Route 2m wide 1 lux min
• First fix base with heavy duty connector capable of accepting Self 2.5 2.7 - - 17.1 7.8
contained
2 x 2.5mm2 cables 2.8 2.2 - - 18.6 8.4
3.0 1.9 - - 19.6 8.6
• Touch safe components when gear tray removed Open Area optic (Symmetric) Open (anti-panic) area 0.5 lux min
Self 2.5 1.7 5.3 10.5 10.5 5.3
contained
• BESA box entry on rear, 20mm conduit entry on ends and sides 2.8 1.4 5.7 11.5 11.5 5.7
3.0 1.2 5.9 12.2 12.2 5.9
• Plug in gear tray 4.0 0.67 4.9 12.5 12.5 4.9
Open Area optic (Symmetric) Open area 1.0 lux min
• To prevent unauthorised access, a tool is required to remove Self
contained
2.5 1.7 4.3 9.4 9.4 4.3
2.8 1.4 3.3 9.3 9.3 3.3
diffuser and internal components 3.0 1.2 3.2 9.2 9.2 3.2
Options
• Maintained luminaire can be operated in non-maintained mode
• Intellem Self test 20 metres
Specification W
L
Catalogue numbers
Zetalite 3 is the first LED luminaire designed • Versatile multi-functional use (escape, open area
specifically for optimal performance from an LED anti-panic and exit signage)
light source. The result is exceptional performance, • Exit sign viewing distance of up to 20 metres
stunning uniformity and low energy usage at a
• IP65 ingress protection suitable for indoor and
traditional 8W bulkhead price point.
outdoor applications
Zetalite 3 is suitable for use as an escape route, • Low power consumption reducing cost of
open area anti-panic emergency lighting and external ownership
over door lighting to provide safe egress from
• Configurable as maintained or non-maintained
buildings. In addition to emergency lighting, Zetalite
operation
3 is also suitable for use as an exit sign with the
application of the optional stick on legend kit. • 3 year warranty for peace of mind
• 50,000 hour life LED (L80) for reduced
maintenance
• One product fulfils all project needs
• “Honeycomb” drilling matrix on base to allow
alignment with existing fixing points for ease of
retro fit
Options
• Luminaire can be operated in maintained or non-maintained
mode
• Use either as emergency luminaire or exit sign Catalogue numbers
Specification Weight
System Mode Cat No (kg)
Self-contained – To specify: IP65 self-contained emergency
luminaire with 12x0.25W LEDs, suitable for use as an emergency Maintained/Non maintained 3Hr ZEL3ICEL 0.45
luminaire or escape exit sign by application of a stick on legend,
NiCd Battery, as per Zetalite 3 range, part no. ________
Single side legend panels
European format self adhesive legend kit ZELLEG 0.05
ISO7010 format self adhesive legend kit ZELLEG-ISO 0.05
Dimensions
L
ISO7010 format double side legend kit ZELLEGDB-ISO 0.05
W
Note: Zetalite 3 is not provided with a switched input and therefore cannot be
used in switched maintained mode with a remote supply to transfer between
L (mm) W (mm) D (mm) maintained and non-maintained mode.
Single Sided Exit Sign 209 118 65
* (not including Exit legend)
Double Sided Exit Sign 209 118 172
Central battery system based emergency lighting is Eaton manufactures a wide range of central battery
ideal for medium to large installations. For projects emergency lighting systems.
where central control and testing is desirable, a
central battery system is a viable and cost effective Loadstar
alternative to self-contained emergency lighting The cost effective Loadstar range consists of AC/AC
products. The main advantages of central battery static inverter systems and a comprehensive range
systems over self-contained systems are: of traditional AC/DC systems, including compact
• Testing and maintenance is much easier to economy ranges designed for use in smaller
carry out installations, all compatible with Eaton’s Easicheck
testing system.
• Battery replacement is much quicker and less
disruptive
ZB-S
• Battery life is generally 10 years or more
• Luminaires can be centrally controlled The higher specification ZB-S system provides
a dependable supply of power to safety and exit
• High light levels can easily be achieved luminaires, as well as testing itself automatically and
• The emergency lighting system can be individually monitoring each CG-S luminaire (up to 20
completely unobtrusive per circuit), all using the power supply cable alone.
Type of system
There are numerous different combinations of central battery system type and the correct choice depends as much on customer
preference as on design criteria. The selection chart below gives some general guidance. Should you wish to discuss a proposed system
type for a particular application, our technical department is available to provide assistance.
Contact the Central System Technical Sales department, Tel: 01302 303317
Dedicated
Some
of the
lighting
Notes
1. Conversion modules are designed to be incorporated into a 3. Static inverter systems operate the emergency luminaires at full
conventional mains luminaire. During normal conditions the brightness throughout the emergency autonomy period, which
luminaire operates at full brightness (using the normal switched usually results in significantly improved luminaire spacing for
mains supply and conventional control gear). In emergency mains slave luminaires compared with an equivalent low voltage
conditions the luminaire continues to operate at reduced brightness AC/DC unit. In addition, the combination of higher supply voltage
(with the emergency lamp being powered from the conversion and the resultant reduced input current reduces installation costs
module instead of the conventional control gear). Conversion by allowing the use of smaller distribution cables than would be
modules are ideal for use with mains luminaires which have required with a lower voltage AC/DC system.
louvres with a sharp cut off angle, or for projects where the mains
luminaires have multiple tubes, but only one tube is required to be
illuminated during emergency conditions.
2. Static inverters provide mains voltage output during both normal
and emergency conditions. They are designed to run conventional
mains fittings at full brightness even in emergency conditions.
Static inverters are ideal for projects with large open areas, or
hazardous areas requiring higher than normal emergency lighting
levels, or for powering compact fluorescent luminaires where there
is often insufficient space within the fitting to accommodate a
conversion module.
Eaton’s Intelligent Lighting System (ILS) is one of • Energy saving - typically between 50% and 70%
the most advanced lighting and energy management • Occupancy detection, daylight linking and
systems available today. System intelligence is constant illumination
built into every luminaire, monitoring and reacting
• Absence functionality (manual on, auto off)
to occupancy, pre-selected light levels and changes
maximises energy saving and compliance with
in ambient daylight levels. Absence functionality is
building regulations and ECA control factors
incorporated to maximise energy saving and controls
factor compliance with buildling regulations. • Flexible programming via a hand-held unit
• Luminaire communication for high light quality
The result is a highly efficient and intelligent system,
via BUS communication loop
which is easily re-configured as room layout or
usage changes, via a simple hand-held infra-red • User infra-red override facility for local control
programmer. Importantly, ILS fully considers the • Simple to install and set up
human dimension. Luminaires communicate with • Easy to re-configure when office layout changes
each other, allowing selected fittings to switch
• Groups can be created and controlled together
on together offering a pleasant, safe and correctly
illuminated environment. A handy infra-red override • Choice of standard 50mm ‘cube’ or mini head
sensor to best suit the chosen luminaire or
unit also provides local control for individuals on
application
a temporary basis. Whatever the application, ILS
delivers automatic energy savings combined with • Designed for use with DALI dimming control
outstanding flexibility. gear (DSI or Analogue 1-10V versions to special
order)
Daylight linking
Natural daylight can often provide either sufficient or a significant until minimum output is reached. With continuing or sustained
contribution to workplace illumination, particularly in the 5 metre daylight availability, the luminaires can be instructed to stay on
area next to windows known as the window zone. Potential and continue to operate at low levels of output, or switch off after
savings due to daylight alone are typically between 50% and a timed period. If daylight decreases, lamps are automatically
70%, dependent on the size, position and compass direction of brightened to maintain the pre-selected light level.
windows. However, most people will not turn off the lights and
Each luminaire reacts independently, to take into account that
the perceived difference between 100% on and switched off
the further away from the window it is installed, the influence
appear to be large. Additionally, turning the lights off will affect
of daylight decreases. ILS automatically compensates for light
everybody, including some who may still require illumination.
received from other luminaires and the use of window blinds or
ILS overcomes this by having a built-in light sensitive cell that curtains. It also has a built in time delay so that it is unaffected by
monitors daylight levels and adjusts lamp output accordingly, so temporary changes in level due to reflections or clouds passing
that the pre-set light level is maintained. As daylight becomes over the sun. The luminaire provides light according to the actual
available, the luminaires react by dimming the lamps, continuing conditions directly beneath it.
Using a conventional luminaire, artificial light is needed at the start and end of ILS daylight linking feature reduces light output and energy used but ensures
the day, but provides too much light for most of the day (because of daylight) that the installation has enough light
thus wasting energy
Eaton
Electrical Sector EMEA
Route de la Longeraie 7
1110 Morges
Switzerland
Eaton.eu
© 2015 Eaton
Eaton All Rights Reserved
Cooper Lighting and Safety Ltd Printed in UK
Wheatley Hall Road Publication No. CLS-CA455001EN
Doncaster Article No. CLS-CC2850
South Yorkshire September 2015
DN2 4NB
Eaton is a registered trademark
Tel: +44 (0)1302 303303 of Eaton Corporation.
Fax: +44 (0)1302 367155
Web: www.cooper-ls.com All other trademarks are property of
Email: [email protected] their respective owners.