SonoRad V10
Excellent Ergonomics
SonoRad V10
Display Duo
Dual Screen Display for Enhanced Clinical Value
Monitor
Touch Panel
• 90% image area
• Full Screen function delivers
large size images
• Detect the focus position • Adjust the ROI direction • Freedom to perform
automatically according to the automatically and PFR in color image adjustments
depth mode and doppler gate in PW • Faster scanning time
• Focus on the interesting area to mode
improve the quality • Time saving, efficient and easy for
the Sonographer
Streamlined Workflow
S u p e ri o r U se r E x p e ri e n ce
• Dual Screen Image Display
02 E a sy D a ta Tra nsfer
• Large Capacity for Cine Loop,
Patient Information &
Image Storage
ST REAMLI N E D • Multi Image & Video Save Format
WORKF LOW • DICOM 3.0
• 6 USB Ports
04 Image O ptimization
• One Touch Image Optimization
• One Touch Flow Optimization
• One Touch Spectrum Optimization
• One Touch Contrast Adjustment
4D
Lightweight and Compact Volume probe allows for smooth display of Fetal
movements. Highly visible volume data can be obtained easily with the
probe. Four dimensional imaging can play a role as a prenatal
communication tool connecting mother with her fetus.
Intelligent software for OB offers High The TV probe with 210o FOV supports High resolution B-Mode images are
efficiency and precise measurement precision and safety for biopsy essential in an OB fetal ultrasound
tools with One step to obtain the procedures and focuses on improving scan to define pregnancy, observe
results. patient comfort and offers exceptional fetal growth and to exclude anomalies.
Auto measurements: image quality throughout the wide
BPD, HC, AC, FL, NT. sector angle.
Auto follicular Volume Measurement Obstetric Doppler measurements with Offers significant improvements in
provides quicker analysis of follicular one touch Angle correction and One image resolution and structure
number and size than conventional 2D touch spectrum correction/inversion visualization in obese patients during
ultrasound, without any loss in improves the workflow for the the 2nd trimister of pregnancy. THI
measurement validity. A time saving clinicians and reduces the extra improves signal-to-noise ratio with
tool in an extremely tedious procedure burden of additional adjustments reduced artifacts
of measuring total follicular volume.
High Resolution B mode image can be obtained with Color Flow is essential for conclusive diagnosis as it
reduced speckle noise with evenly clear edges by provides the path of the blood flow for better
selectively emphasizing boundaries visualization of any abnormalities in the particular
organ
Automatically traces the intima, and measures the Displays the elasticity of different tissues in different
thickness of the intima. This allows you to measure color. Provides more clinical information especially
the intima faster with more accuracy. By setting an for breast tumor, thyroid, liver and prostate. Strain
ROI vessel’s longitudinal image, max and mean IMT ratio measurement quantitatively gives the ratio
can be computed automatically. This is favourable in between the average strain of the selected region
determining the extent of plaque build-up in walls of and the nearby normal tissue region. Available on
arteries various probes
Trapezoidal Imaging offers an extended field of view Quadplex Mode: delivers live measurements of
permitting greater understanding of the orientation Doppler parameters in Triplex Mode. Online
and size of the target and its surroundings. This is estimation without freezing makes workflow faster
really advantageous in case of examination of and helps in clinical decision while exam is on.
appendix/bowel in abdomen study or examination of
thyroid in study of small parts
High resolution B mode image provides clarity in Color M-Mode helps to evaluate the myocardium
imaging that contributes to reduced examination and blood flow to provide a robust analysis of the
time and improved workflow. Improved contrast, cardiac rhythm for the evaluation of cardiovascular
along with reduction in speckle and acoustic noise risk at an early stage. This helps in the assessment
improve the diagnostic value of echocardiography of LV Function or fetal arrhythmias.
images.
Tissue Doppler Imaging Tissue Doppler Velocity
Tissue Doppler Imaging allows truly quantitative This technique helps in evaluating the time motion
measurement of regional myocardial function. It display of the functional cardiac structures. This is
helps in diagnosis of diastolic left ventricular done to analyse the presence of deformation and or
dysfunction, Right ventricular function, intracardiac to analyse the myocardial velocity in order to
and pulmonary artery pressures, transplant evaluate the functioning of heart.
rejection and intraventricular dyssynchrony.
High resolution analysis of myocardial functions of a CW Doppler study allows high velocity blood flows to
fetal heart using 3 different axes is possible. The be observed and measured accurately. The high
cursor can be placed optimally to examine the heart sensitivity continuous wave Doppler with waveform
function accurately irrespective of the direction. In a smoothing provides a continuity of display.
single heart beat cardiac wall motion in multiple
Available with
areas and valves can be compared.
ECG Module | Continous Wave Doppler
Cardiac Software Package
Smart HIP
Graph Display for hip orthotics diagnosis helps
clinicians to provide accurate diagnosis during
the paediatric hip scanning.
HD CZoom
Zoom the color information with high resolution.
Virtual Convex
Enlarge the scanning area in convex probe
as same as convex trapezoid