Design Paramters: With Sagrod at Midspan

1) The document provides design parameters for roof purlins including dimensions, spacing, loads, and wind speed. 2) It calculates design wind pressure and resulting maximum and minimum wind loads on the purlins. 3) Load combinations are analyzed and checks are performed to ensure stresses in the purlins and deflections meet allowable limits.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
293 views1 page

Design Paramters: With Sagrod at Midspan

1) The document provides design parameters for roof purlins including dimensions, spacing, loads, and wind speed. 2) It calculates design wind pressure and resulting maximum and minimum wind loads on the purlins. 3) Load combinations are analyzed and checks are performed to ensure stresses in the purlins and deflections meet allowable limits.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 1

Design Paramters

Fbx = Fby 148.80 Mpa Wind Load: P = qh[GCp - GCpi]


# of sagrod = 1 With sagrod at midspan Exposure: B
# of purlin = 9 Height: 7.00 m
Live Load = 0.600 kPa Basic Wind Speed: 250 km/hr
Spacing, S = 0.850 m, tributary width Windward, Pres Coef, GCp: 0.47
Span, L = 2.500 m Leeward, Pres Coef, GCp: -0.89
Roof Angle, q = 20.0000 degrees Positive Int. Pressure Coef., GCpi: 0.18
Ceiling = 0.200 kPa Negative Int. Pressure Coef., GCpi: -0.18
Roof = 0.100 kPa Topographic Factor, Kzt: 1.00
Utilities = 0.100 kPa Kz = 0.649
Total Dead Load = 0.40000 kPa

TRIAL SECTION AND SECTION PROPERTIES


h= 75 mm
b= 50 mm
L= 20 mm
t= 1.2 mm
Area = 252.24 mm2
Weight = 0.0194225 KN/m
cy = 37.50 mm
cx = 20.94 mm
Sx = 6284.04 mm3
Sy = 3426.47 mm3

DESIGN WIND PRESSURE COMPUTED DESIGN LOADS


qh = 0.613KzKztKdV2 Maximum Pressure = 1.060 kPa
qh = 1631.043 N/m2 Maximum Suction = -1.745 KPa
qh = 1.631 kPa DL = 0.3400 kN/m
Case1 Windward = 1.060 LL = 0.510 kN/m
Leeward = -1.158 Wlpres = 0.901 kN/m
Case2 Windward = 0.473 Wlsuct = -1.483 kN/m
Leeward = -1.745

Load Combinations Wn Mn fbx Wt Mt fby fbx + fby fbx/Fbx + fby/Fby Remarks

DL + LL 0.8169898888 0.638273351 101.57052712669 0.29736000122016 0.0580781252383 33.89971222195 135.470239349 0.9 Pass


0.75DL + 0.45WLPRES 0.65882793522 0.514709324 81.907379250656 0.09219729609305 0.0180072843932 10.51070013577 92.4180793864 0.6 Pass
0.75DL + 0.45WLSUCT -0.41423493746 -0.323621045 -51.498875969368 0.09219729609305 0.0180072843932 10.51070013577 -40.9881758336 -0.3 Pass

DIAMETER OF SAGROD
T = # of purlin x tangential reaction
= 4.182 kN
Diameter = 6.0 say 10 mm sagrods

CHECK FOR DEFLECTION


L (mm) W (KN/m) E I DEFLECTION ALLOWABLE REMARKS
2,500.00 0.817 200000.000 235,651.54 8.817 10.417 Pass
2,500.00 0.659 200000.000 235,651.54 7.110 10.417 Pass
2,500.00 -0.414 200000.000 235,651.54 -4.470 10.417 Pass