Generator - Kohler Power System

This document provides specifications for a 150EOZ (60 Hz) or 125EFOZ (50 Hz) marine generator set including: - Dimensions, weights, and ratings for continuous power output - Technical details on the diesel engine such as manufacturer, model, power output, and lubrication system - Configuration and control options for the generator and engine - Cooling requirements and fuel consumption at different loads

Uploaded by

Brillyan
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
232 views

Generator - Kohler Power System

This document provides specifications for a 150EOZ (60 Hz) or 125EFOZ (50 Hz) marine generator set including: - Dimensions, weights, and ratings for continuous power output - Technical details on the diesel engine such as manufacturer, model, power output, and lubrication system - Configuration and control options for the generator and engine - Cooling requirements and fuel consumption at different loads

Uploaded by

Brillyan
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Model: 150EOZ (60 Hz)

125EFOZ (50 Hz)


3-Phase Diesel

Marine Generator Set


Generator Features
D Remote control connector
D Class H insulation
D Reconnectable voltage
D 60/50 Hz field adjustable generator set
D One- or three-phase reconnectable alternator
D Voltage regulation of ±2%
D Frequency regulation of ±5%

Optional Accessories
D Sound shield
D Power takeoff (PTO)
D Electronic governor
D Paralleling governor
D Circuit breakers

Generator Weights and Dimensions


Without With
Sound Shield Sound Shield
Weight, kg (lb.)
Wet 1601 (3530) 1760.0 (3880)
Dry 1569 (3460) 1728.0 (3810)
Length, mm (in.) 2291.1 (90.20) 2450.1 (96.46)
Width, mm (in.) 810.5 (31.91) 810.5 (31.91)
Height, mm (in.) 1056.8 (41.61) 1127.5 (44.39)

See the drawings on the last page for detailed dimensions.

Generator Ratings
Model 25_C (77_F) Continuous Rated
Series Voltage Hz Amps kW/kVA (25°C) Ph
120/208 60 521 150/187.5 3
120/240 60 451 150/187.5 3
120/240 60 416 100/100 1
150EOZ 127/220 60 492 150/187.5 3
139/240 60 451 150/187.5 3
220/380 60 279 147/184 3
277/480 60 225 150/187.5 3
110/190 50 475 125/156 3
110/220 50 410 125/156 3
110/220 50 400 88/88 1
125EFOZ
220/380 50 237 125/156 3
230/400 50 225 125/156 3
240/416 50 217 125/156 3
RATINGS: Marine continuous ratings per ISO 3046, ISO 8528-1, and Kohler ISO rating guideline
2.14. Obtain technical information bulletin (TIB-101) on ratings guidelines for complete ratings
definitions.
Availability is subject to change without notice. Kohler Co. reserves the right to change the design or
specifications without notice and without any obligation or liability whatsoever. Contact your local
Kohler generator set distributor for availability.

G2-75 (150EOZ) 3/02c


Application Data
Engine Lubrication
Engine Specifications 60 Hz 50 Hz Lubricating System 60 Hz 50 Hz
Manufacturer John Deere Oil pan capacity with filter, L (U.S. qt.) 31.94 (33.75)
Model 6081AFM Type Pressure
Type Inline, 4-cycle
Number of cylinders 6 Operation Requirements
Firing order 1-5-3-6-2-4
Air Requirements 60 Hz 50 Hz
Aspiration Turbocharged
Engine combustion air requirements,
Displacement, L (cu. in.) 8.1 (496) L/min. (cfm) 10902 (385) 6739 (238)
Bore and stroke, mm (in.) 116 x 129 (4.56 x 5.06) Cooling air required for generator set at
Compression ratio 16.5:1 14_C (25_F) rise, m3/min. (cfm) N/A N/A
Combustion system Direct injection Exhaust gas flow, m3/min. (cfm) 21.9 (774) 18.3 (645)
Rated rpm 1800 1500 Fuel Consumption 60 Hz 50 Hz
Maximum power at rated rpm, HP 255 186 Diesel, Lph (gph) at % load
Cylinder block material Cast iron 100% 40.5 (10.7) 33.7 (8.9)
Cylinder head material Cast iron 75% 30.7 (8.1) 26.1 (6.9)
Piston rings 2 compression/1 oil 50% 22.0 (5.8) 18.9 (5.0)
Crankshaft material Forged steel 25% 14.0 (3.7) 11.4 (3.0)
Connecting rod material Forged steel
Governor type Mechanical (standard)
Electric (optional)
Engine Features
D One-side serviceability of fuel system, lubrication system, and air
cleaner
Engine Electrical
D Low oil pressure cutout
Engine Electrical System 60 Hz 50 Hz D High water temperature cutout
Battery, voltage 12- or 24-volt spec
D Loss of coolant cutout
Battery, charging (12 volt) 90 amp
D Overcrank cutout
Battery, charging (24 volt) 60 amp
D Belt guard
Battery, recommendation
(minimum, 12 volt) 800 CCA D Optional oil pressure gauge, water temperature gauge, and battery
voltage gauge
Starter motor Gear-reduction type
D Disposable oil filter

Cooling D Extended oil drain


D PTO options: 12- or 24-volt electric clutch
Cooling System 60 Hz 50 Hz
Capacity, L (U.S. qt.) (approx.) 28 (30)
Controller Features
Cooling type Heat exchanger
D Rubber mounted to isolate vibration
Seawater pump type John Deere gear driven
D Safety shutdowns
Seawater pump suction lift,
maximum, m (ft.) 0.9 (3.0) d Engine overheating
Heat rejected to cooling water at rated d Low oil pressure
kW, wet exhaust, kW (Btu/min.) 109 (6170) 101 (5720)
d Overcrank
Engine water pump flow, Lpm (gpm) 269 (71) 208 (55)
D Safety shutdown lamp
Seawater pump flow, Lpm (gpm) 83 (22) 68 (18)
D Shutdown reset switch

Fuel D Terminal strip connection for remote panel harness


D Hourmeter for scheduling maintenance
Fuel System 60 Hz 50 Hz
D Voltage-adjusting rheostat
Fuel recommendation Diesel fuel specified to
EN 590 or ASTM D975 D Start/stop switch
Fuel shutoff solenoid Electric
Fuel injection pump Bosch
Fuel pump priming Manual
Maximum recommended fuel lift, m (ft.) 0.9 (3.0)

G2-75 (150EOZ) 3/02c


Controller Options Alternator Specifications
Decision-Makert
t 3+ Controller Features Alternator Specifications
Fast-Responset
Specifications Generator
Manufacturer Kohler
Type 4-pole, rotating-field
Exciter type Brushless,
D Type: 16-light microprocessor (NFPA 110, level 1) permanent-magnet,
D Power source, with circuit protection: 12-volt DC Fast-Responset
D Panel lamps (2) Number of leads 12, reconnectable
D Analog Meters: Voltage regulator Solid state, volts/Hz
d AC meters, 89 mm (3.5 in.) 2% full-scale accuracy on Insulation: NEMA MG1-1.66
voltmeter and ammeter, 0.5% full-scale accuracy on
frequency meter Material Class H
d DC meters, 51 mm (2 in.), volts, engine water temperature, Temperature rise 120_C
oil pressure
Bearing: number, type 1, sealed
d Running time meter
Coupling Flexible disc
D Switches and Controls:
d Alarm horn and silencing switch Amortisseur windings Full
d Cyclic cranking Voltage regulation, no load to full load ±2%
d Engine cooldown timer, 5 minute One-step load acceptance per NFPA 110 100% of rating
d Front-mounted voltage-adjusting rheostat ±5% Peak motor starting kVA—4S13 N/A (60 Hz), N/A (50 Hz)
d Lamp-test switch
d Local emergency stop button switch (optional)
Alternator Features
d Meter-phase selector switch, 7-position
D The generator complies with NEMA, IEEE, and ANSI standards
d Overvoltage protection shutdown for temperature rise.
d Prime power mode
D The alternator uses a permanent-magnet, Fast-Responset
d Run/off-reset/auto switch (engine start), local/remote two-wire excitation system.
D Fault and Condition Lamps: D The alternator has a two-thirds pitch stator and skewed rotor.
d Auxiliary fault (red)
D The generator has a solid-state, volts-per-hertz voltage regulator.
d Auxiliary prealarm (yellow)*
D The brushless, synchronous generator is broadrange and
d Battery charger fault (red)* reconnectable.
d Emergency stop (red)*
D The windings are vacuum-impregnated with fungus-resistant
d Generator switch not-in-auto (red) epoxy varnish.
d High engine temperature safety shutdown (red) D The generator sustains short-circuit current up to 300% of the
d Low battery voltage (red)* rated current for up to 10 seconds.
d Low coolant level shutdown (auxiliary)
d Low fuel (red)* Accessories/Options
d Low oil pressure safety shutdown (red) D Electronic governor
d Low water temperature (red)* D Fluid-filled isolation mounts
d Overcrank safety shutdown (red) D Electric front clutch PTO (12- or 24-volt)
d Overspeed safety shutdown (red) D Line circuit breaker
d Prealarm high engine temperature (yellow)*
D DEC 3+ controller
d Prealarm low oil pressure (yellow)*
D Sound shield
d System ready (green)
* Requires an optional kit or a user-provided device for lamp to D Remote control panel
function. D Siphon break
D Overspeed shutdown kit
Manual Controllers D Remote connection/extension harness
D Standard Decision-Makerä 1 controller
D Safeguard breaker
D Expanded Decision-Makerä 1 controller with engine gauges and AC
meters D Fuel filter
(For manual controller features, see the marine controller spec sheet.) D Oil level indicator (high/low)
D Low coolant level indicator
D Crankcase emission canister

G2-75 (150EOZ) 3/02c


KOHLER CO., Kohler, Wisconsin 53044 USA
Phone 920-565-3381, Fax 920-459-1646
For the nearest sales and service outlet in the
US and Canada, phone 1-800-544-2444
KohlerPowerSystems.com

ADV-6594A-B

ADV-6594B-B

DISTRIBUTED BY:

NOTE: Dimensions in [ ] are inch equivalents.


NOTE: This drawing is provided for reference only and is not
intended for installation planning. Contact your local
distributor for more detailed information.
E 2000, 2002 by Kohler Co. All rights reserved.

G2-75 (150EOZ) 3/02c

You might also like