FLOWMETER
PRODUCT CATALOG
FM
Pflow is the national branch of Gentos Measurement & Control Co. Ltd. Gentos
focus on ultrasonic flow meter since 1993.Now we have formed our production
system, the ultrasonic flow meter as the leader.
2004 Completed the fuel test standard “Rockets Attitude Control” of China
Aerospace.
2018 Develop smart air conditioning, smart water strategy, and product + IOT
CERTIFICATE
R&D CENTER
ENGINEERING TEAM
WWW.PFLOW.COM.CN
PRODUCTS
Model D116 D118 D118i P117 P118i E3
Flow Velocity 0.03 ~ ±16ft/s (0.01 ~ ±5m/s) 0.03 ~ ±40ft/s (0.01~ ±12m/s) 0.03 ~ ±40ft/s (0.01~ ±12m/s) ±0.03 ~ ±20 ft/s (±0.01~ ±6 m/s) 0.03~40ft/s (0.01~12m/s) 0.098 ~ ±16ft/s (0.03m/s ~ ±5m/s)
Pipe size 1”~48” (25mm ~ 1200mm) 1″~200″(25mm ~ 5000mm) 1″~200″(25mm ~ 5000mm) 1”~48” (25mm ~ 1200mm) 1″~240″ (25 ~ 6000mm) DN20 ~ DN80(optional)
Accuracy +/-1.0% +/-0.5% +/-0.5% +/-1.0% +/-0.5% +/-2.0%
Repeatability 0.30% 0.15% 0.10% 0.30% 0.15% 0.40%
Application water, sound-conducting liquid
water, fuel, oil and chemicals water, fuel, oil and chemicals water, fuel, oil and chemicals water, fuel, oil and chemicals water, sound-conducting liquid
Pipe Material 1. Carbon Steel 2. PVC 1. Carbon Steel 2. PVC 1. Carbon Steel 2. PVC 1. Carbon Steel 2. PVC 1. Carbon Steel 2. PVC Carbon steel, Stainless steel, PVC,
3. Stainless Steel 4. Aluminum
3. Stainless Steel 4. Aluminum 3. Stainless Steel 4. Aluminum 3. Stainless Steel 4. Aluminum 3. Stainless Steel 4. Aluminum Copper (optional)
5. Copper 6. Ductile Iron
5. Copper 6. Ductile Iron 5. Copper 6. Ductile Iron 5. Copper 6. Ductile Iron 5. Copper 6. Ductile Iron
7. Cast Iron 8. Other 7. Cast Iron 8. Other 7. Cast Iron 8. Other 7. Cast Iron 8. Other 7. Cast Iron 8. Other
I/O 1. OCT Pulse output:0~5000Hz.
1. Analog output: 4~20mA, max 1. Analog output: 4~20mA, max 1. Analog output: 4-20mA 1. Analog output: 4-20mA Standard:
2. Analog output:4~20mA,max load
load 750Ω. load 750Ω. 2. RS485 2. RS485 WiFi/TTL
750Ω. 2. Pulse output: 0~9999Hz, OCT 2. Pulse output: 0~9999Hz, OCT 3. Pulse output: OCT Optional:
3.Relay 3. Realy output: max. frequency 3. Realy output 4. Relay 4-20mA/TTL, RS485/TTL,
4.RS485 Modbus 1Hz(1A@125VAC or 2A@30VDC) 4. RS485A/RS485B/RS232 OCT/Relay
4.RS485 & RS232 5. Analog input
5.Analog input 6. RTD input
Power 10 ~ 36VDC/1A 90 ~ 245 VAC (48 ~ 63 Hz) Or 10 ~ 90 ~ 245 VAC (48 ~ 63 Hz) Or 10 ~ Rechargeable Lithium Battery Rechargeable Lithium Battery 10~36VDC/500mA
supply 36 VDC. 36 VDC. Power Power
Temperature Ambient: 14℉~122℉(-10℃~50℃) Ambient: 14℉~122℉(-10℃~50℃) Ambient: 14℉~122℉(-10℃~50℃) Ambient: 14℉~122℉(-10℃~50℃) Ambient: 14℉~122℉(-10℃~50℃) Ambient: 14℉~122℉(-10℃~50℃)
Fluid: 32℉~176℉(0℃~80℃) Fluid: -40℉~176℉(-40℃~80℃) Fluid:-40℉~176℉(-40℃~80℃) Fluid: -40℉~176℉(-40℃~80℃) Fluid: -40℉~176℉(-40℃~80℃) Fluid: 32℉~140℉(0℃~60℃)
Transmitter PC/ABS, IP65 Die-cast aluminum, IP65 Die-cast aluminum, IP65 NEMA13(IP54) NEMA13(IP54) IP54
Transducer Encapsulated design, IP68 Encapsulated design, IP68 Encapsulated design, IP68 Encapsulated design, IP68 Encapsulated design, IP68 IP54
Transducer Standard cable length: 30ft(9m) Standard / Maximum cable length: Standard cable length: 30ft(9m) Standard cable length: 10ft Standard cable length: 10ft φ5 6 core electric cable,standard
cable 30ft / 1000ft ( 9m/305 m ). length:2m
Features Clamp-on Transducers; Clamp-on Transducers; Clamp-on Transducers; Clamp-on Transducers; Clamp-on Transducers; Cloud Data Storage System
Fixed-mounted meter; Fixed-mounted meter; Insertion Transducers; Portable & Easy to carry; Portable & Easy to carry; Heat Consumption Measurement
Temp. sensors available High temp. version available Fixed-mounted meter; High temp. version available
High temp. version available Temp. sensors available
Product View
WWW.PFLOW.COM.CN
PRODUCTS
Model E5 E8 F2 F3 F5 F8
Flow Velocity 0.03 ~ ±16ft/s (0.01 ~ ±5m/s) 0.03 ~ ±40ft/s (0.01~ ±12m/s) 0.098 ~ ±16ft/s (0.03m/s ~ ±5m/s) 0.098 ~ ±16ft/s (0.3m/s ~ ±5m/s) 0.03 ~ ±16ft/s (0.01 ~ ±5m/s) 0.03 ~ ±40ft/s (0.01~ ±12m/s)
Pipe size 1”~48” (25mm ~ 1200mm) 1″~200″(25mm ~ 5000mm) DN20 ~ DN80(optional) DN20 ~ DN80(optional) 1”~48” (25mm ~ 1200mm) 1″~200″(25mm ~ 5000mm)
Accuracy +/-1.0% +/-0.5% +/-2.0% +/-2.0% +/-1.0% +/-0.5%
Repeatability 0.30% 0.15% 0.40% 0.40% 0.30% 0.15%
Application water, sound-conducting liquid
water, fuel, oil and chemicals water, sound-conducting liquid water, sound-conducting liquid water, sound-conducting liquid water, fuel, oil and chemicals
Pipe Material 1. Carbon Steel 2. PVC 1. Carbon Steel 2. PVC Carbon steel, Stainless steel, PVC, Carbon steel, Stainless steel, PVC, 1. Carbon Steel 2. PVC 1. Carbon Steel 2. PVC
3. Stainless Steel 4. Aluminum
3. Stainless Steel 4. Aluminum Copper (optional) Copper (optional) 3. Stainless Steel 4. Aluminum 3. Stainless Steel 4. Aluminum
5. Copper 6. Ductile Iron
5. Copper 6. Ductile Iron 5. Copper 6. Ductile Iron 5. Copper 6. Ductile Iron
7. Cast Iron 8. Other 7. Cast Iron 8. Other 7. Cast Iron 8. Other 7. Cast Iron 8. Other
I/O 1. OCT Pulse output:0~5000Hz.
1. Analog output: 4~20mA, max Standard: Standard: 1. OCT Pulse output:0~5000Hz. 1. Analog output: 4~20mA, max
2. Analog output:4~20mA,max load
load 750Ω. WiFi/TTL WiFi/TTL 2. Analog output: 4~20mA,max load load 750Ω.
750Ω. 2. Pulse output: 0~9999Hz, OCT Optional: Optional: 750Ω. 2. Pulse output: 0~9999Hz, OCT
3.Relay output 3. Realy output 4-20mA/TTL, RS485/TTL, 4-20mA/TTL, RS485/TTL, 3.Relay output 3. Realy output
4.RS485/RS232 4.RS485/RS232 OCT/Relay OCT/Relay 4.RS485/RS232 4.RS485/RS232
5.RTD input 5.RTD input 5.WiFi 5.WiFi
6.WiFi 6.WiFi
Power 10~36VDC/1A 90 to 245 VAC, 48 to 63 Hz. Or 10 10~36VDC/500mA 10~36VDC/500mA 10~36VDC/1A
90 to 245 VAC, 48 to 63 Hz. Or 10
supply to 36VDC to 36VDC
Temperature Ambient: 14℉~122℉(-10℃~50℃) Ambient: 14℉~122℉(-10℃~50℃) Ambient: 14℉~122℉(-10℃~50℃) Ambient: 14℉~122℉(-10℃~50℃) Ambient: 14℉~122℉(-10℃~50℃) Ambient: 14℉~122℉(-10℃~50℃)
Fluid: 32℉~176℉(0℃~80℃) Fluid: 32℉~176℉(0℃~80℃) Fluid: 32℉~140℉(0℃~60℃) Fluid: 32℉~140℉(0℃~60℃) Fluid: 32℉~176℉(0℃~80℃) Fluid: 32℉~176℉(0℃~80℃)
Transmitter PC/ABS,IP65. NEMA 4X (IP65), Die-cast IP54 IP54 PC/ABS,IP65. NEMA 4X (IP65), Die-cast
Transducer Encapsulated design,IP68 aluminum
Encapsulated design,IP68 Clamp on Clamp on Encapsulated design,IP68. aluminum
Encapsulated design
Transducer Standard cable length:30ft(9m). Standard/maximum cable φ5 six core cable, standard length: φ5 six core cable, standard length: Standard cable length:30ft(9m). Standard/maximum cable
cable length:30ft/1000ft(9m/305m) 2m 2m length:30ft/1000ft(9m/305m)
Features Clamp-on Transducers; Clamp-on Transducers; Cloud Data Storage System Cloud Data Storage System Clamp-on Transducers; Clamp-on Transducers;
Fixed-mounted meter; Fixed-mounted meter; Fixed-mounted meter; Fixed-mounted meter;
Clound service; Clound service; Clound service; Clound service;
Heat measurement Heat measurement; High temp. version available
High temp. version available High temp. version available
Product View
www.pflow.com.cn
QUALITY CONTROL
CALIBRATION
Axial double-loop flow calibration device adopts 3488D Heat meter flow calibration system can be used to
multipath ultrasonic flow meter as a master meter. The calibrate the hot (cold) flowmeter DN15~DN50, the
master meter takes our PICOFLY technology, the measuring medium temperature which can be
resolution has reached 0.01 nanoseconds, realize single maintained at 50 ℃ + 5℃.
point repeatability of 0.04%.
DN100 axial flow calibration device is mainly used in Liquid Flow calibration device adopts weighing method
volume production product calibration, the calibration to calibrate, suitable for flowmeter in DN8 ~ DN80.
device can be inspection 6 sets flowmeter at the same