0% found this document useful (0 votes)
203 views7 pages

Product Catalog of PFlow

This document provides information on Gentos Measurement & Control Co., Ltd and their line of ultrasonic flow meters. Some key details include: - Gentos was established in 1993 in Shenzhen, China and focuses on ultrasonic flow meter production. - They have obtained various qualifications and certifications over the years and participated in international trade shows and competitions. - The document describes several models of ultrasonic flow meters in their product line, including specifications like flow velocity range, pipe sizes, accuracy, and features. - Gentos has an R&D center and engineering team and has achieved applications in various industries like aviation and smart buildings.

Uploaded by

Le Vinh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
203 views7 pages

Product Catalog of PFlow

This document provides information on Gentos Measurement & Control Co., Ltd and their line of ultrasonic flow meters. Some key details include: - Gentos was established in 1993 in Shenzhen, China and focuses on ultrasonic flow meter production. - They have obtained various qualifications and certifications over the years and participated in international trade shows and competitions. - The document describes several models of ultrasonic flow meters in their product line, including specifications like flow velocity range, pipe sizes, accuracy, and features. - Gentos has an R&D center and engineering team and has achieved applications in various industries like aviation and smart buildings.

Uploaded by

Le Vinh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

Gentos Measurement& Control Co.

, Ltd

FLOWMETER

PRODUCT CATALOG
FM
Pflow is the national branch of Gentos Measurement & Control Co. Ltd. Gentos
focus on ultrasonic flow meter since 1993.Now we have formed our production
system, the ultrasonic flow meter as the leader.

1993 Established in shenzhen , the city of science and technology . the


birthplace of many high-tech companies such as HUAWEI, TENCENT and
GENTOS.

1999 Obtained the Building Automation qualification certificate.

2004 Completed the fuel test standard “Rockets Attitude Control” of China
Aerospace.

2009 Innovated Picofly technology , applied Picofly technology into ultrasonic


flowmeter.

2011 Cooperation with HongKong polytechnic university and Harbin institute of


technology university to prove Picofly in very fine time resolution.

2016 Participated in HANNOVER MESSE with the new products , Compound


Multipath ultrasonic flowmeter D348DS plus and Smart Crystal F200.

2017 Gentos has achieved application of The Ultrasonic


Mass Flow Measurement on China Air Force.

2018 Develop smart air conditioning, smart water strategy, and product + IOT

2019 Invited to participate in the 23rd National Invention Exhibitionone--B&R


and the BRICs Technology Development and Technology Innovation
Competition, and won the silver award.
www.pflow.com.cn

CERTIFICATE

R&D CENTER

ENGINEERING TEAM
WWW.PFLOW.COM.CN

PRODUCTS
Model D116 D118 D118i P117 P118i E3
Flow Velocity 0.03 ~ ±16ft/s (0.01 ~ ±5m/s) 0.03 ~ ±40ft/s (0.01~ ±12m/s) 0.03 ~ ±40ft/s (0.01~ ±12m/s) ±0.03 ~ ±20 ft/s (±0.01~ ±6 m/s) 0.03~40ft/s (0.01~12m/s) 0.098 ~ ±16ft/s (0.03m/s ~ ±5m/s)

Pipe size 1”~48” (25mm ~ 1200mm) 1″~200″(25mm ~ 5000mm) 1″~200″(25mm ~ 5000mm) 1”~48” (25mm ~ 1200mm) 1″~240″ (25 ~ 6000mm) DN20 ~ DN80(optional)
Accuracy +/-1.0% +/-0.5% +/-0.5% +/-1.0% +/-0.5% +/-2.0%
Repeatability 0.30% 0.15% 0.10% 0.30% 0.15% 0.40%
Application water, sound-conducting liquid
water, fuel, oil and chemicals water, fuel, oil and chemicals water, fuel, oil and chemicals water, fuel, oil and chemicals water, sound-conducting liquid
Pipe Material 1. Carbon Steel 2. PVC 1. Carbon Steel 2. PVC 1. Carbon Steel 2. PVC 1. Carbon Steel 2. PVC 1. Carbon Steel 2. PVC Carbon steel, Stainless steel, PVC,
3. Stainless Steel 4. Aluminum
3. Stainless Steel 4. Aluminum 3. Stainless Steel 4. Aluminum 3. Stainless Steel 4. Aluminum 3. Stainless Steel 4. Aluminum Copper (optional)
5. Copper 6. Ductile Iron
5. Copper 6. Ductile Iron 5. Copper 6. Ductile Iron 5. Copper 6. Ductile Iron 5. Copper 6. Ductile Iron
7. Cast Iron 8. Other 7. Cast Iron 8. Other 7. Cast Iron 8. Other 7. Cast Iron 8. Other 7. Cast Iron 8. Other
I/O 1. OCT Pulse output:0~5000Hz.
1. Analog output: 4~20mA, max 1. Analog output: 4~20mA, max 1. Analog output: 4-20mA 1. Analog output: 4-20mA Standard:
2. Analog output:4~20mA,max load
load 750Ω. load 750Ω. 2. RS485 2. RS485 WiFi/TTL
750Ω. 2. Pulse output: 0~9999Hz, OCT 2. Pulse output: 0~9999Hz, OCT 3. Pulse output: OCT Optional:
3.Relay 3. Realy output: max. frequency 3. Realy output 4. Relay 4-20mA/TTL, RS485/TTL,
4.RS485 Modbus 1Hz(1A@125VAC or 2A@30VDC) 4. RS485A/RS485B/RS232 OCT/Relay
4.RS485 & RS232 5. Analog input
5.Analog input 6. RTD input
Power  10 ~ 36VDC/1A 90 ~ 245 VAC (48 ~ 63 Hz) Or 10 ~ 90 ~ 245 VAC (48 ~ 63 Hz) Or 10 ~ Rechargeable Lithium Battery Rechargeable Lithium Battery 10~36VDC/500mA
supply 36 VDC. 36 VDC. Power Power
Temperature Ambient: 14℉~122℉(-10℃~50℃) Ambient: 14℉~122℉(-10℃~50℃) Ambient: 14℉~122℉(-10℃~50℃) Ambient: 14℉~122℉(-10℃~50℃) Ambient: 14℉~122℉(-10℃~50℃) Ambient: 14℉~122℉(-10℃~50℃)
Fluid: 32℉~176℉(0℃~80℃) Fluid: -40℉~176℉(-40℃~80℃) Fluid:-40℉~176℉(-40℃~80℃) Fluid: -40℉~176℉(-40℃~80℃) Fluid: -40℉~176℉(-40℃~80℃) Fluid: 32℉~140℉(0℃~60℃)
Transmitter PC/ABS, IP65 Die-cast aluminum, IP65 Die-cast aluminum, IP65 NEMA13(IP54) NEMA13(IP54) IP54
Transducer Encapsulated design, IP68 Encapsulated design, IP68 Encapsulated design, IP68 Encapsulated design, IP68 Encapsulated design, IP68 IP54
Transducer  Standard cable length: 30ft(9m) Standard / Maximum cable length: Standard cable length: 30ft(9m) Standard cable length: 10ft Standard cable length: 10ft φ5 6 core electric cable,standard
cable 30ft / 1000ft ( 9m/305 m ). length:2m
Features Clamp-on Transducers; Clamp-on Transducers; Clamp-on Transducers; Clamp-on Transducers; Clamp-on Transducers; Cloud Data Storage System
Fixed-mounted meter; Fixed-mounted meter; Insertion Transducers; Portable & Easy to carry; Portable & Easy to carry; Heat Consumption Measurement
Temp. sensors available High temp. version available Fixed-mounted meter; High temp. version available
High temp. version available Temp. sensors available
Product View
WWW.PFLOW.COM.CN

PRODUCTS
Model E5 E8 F2 F3 F5 F8
Flow Velocity 0.03 ~ ±16ft/s (0.01 ~ ±5m/s) 0.03 ~ ±40ft/s (0.01~ ±12m/s) 0.098 ~ ±16ft/s (0.03m/s ~ ±5m/s) 0.098 ~ ±16ft/s (0.3m/s ~ ±5m/s) 0.03 ~ ±16ft/s (0.01 ~ ±5m/s) 0.03 ~ ±40ft/s (0.01~ ±12m/s)

Pipe size 1”~48” (25mm ~ 1200mm) 1″~200″(25mm ~ 5000mm) DN20 ~ DN80(optional) DN20 ~ DN80(optional) 1”~48” (25mm ~ 1200mm) 1″~200″(25mm ~ 5000mm)
Accuracy +/-1.0% +/-0.5% +/-2.0% +/-2.0% +/-1.0% +/-0.5%
Repeatability 0.30% 0.15% 0.40% 0.40% 0.30% 0.15%
Application water, sound-conducting liquid
water, fuel, oil and chemicals water, sound-conducting liquid water, sound-conducting liquid water, sound-conducting liquid water, fuel, oil and chemicals
Pipe Material 1. Carbon Steel 2. PVC 1. Carbon Steel 2. PVC Carbon steel, Stainless steel, PVC, Carbon steel, Stainless steel, PVC, 1. Carbon Steel 2. PVC 1. Carbon Steel 2. PVC
3. Stainless Steel 4. Aluminum
3. Stainless Steel 4. Aluminum Copper (optional) Copper (optional) 3. Stainless Steel 4. Aluminum 3. Stainless Steel 4. Aluminum
5. Copper 6. Ductile Iron
5. Copper 6. Ductile Iron 5. Copper 6. Ductile Iron 5. Copper 6. Ductile Iron
7. Cast Iron 8. Other 7. Cast Iron 8. Other 7. Cast Iron 8. Other 7. Cast Iron 8. Other
I/O 1. OCT Pulse output:0~5000Hz.
1. Analog output: 4~20mA, max Standard: Standard: 1. OCT Pulse output:0~5000Hz. 1. Analog output: 4~20mA, max
2. Analog output:4~20mA,max load
load 750Ω. WiFi/TTL WiFi/TTL 2. Analog output: 4~20mA,max load load 750Ω.
750Ω. 2. Pulse output: 0~9999Hz, OCT Optional: Optional: 750Ω. 2. Pulse output: 0~9999Hz, OCT
3.Relay output 3. Realy output 4-20mA/TTL, RS485/TTL, 4-20mA/TTL, RS485/TTL, 3.Relay output 3. Realy output
4.RS485/RS232 4.RS485/RS232 OCT/Relay OCT/Relay 4.RS485/RS232 4.RS485/RS232
5.RTD input 5.RTD input 5.WiFi 5.WiFi
6.WiFi 6.WiFi
Power  10~36VDC/1A 90 to 245 VAC, 48 to 63 Hz. Or 10 10~36VDC/500mA 10~36VDC/500mA 10~36VDC/1A
90 to 245 VAC, 48 to 63 Hz. Or 10
supply to 36VDC to 36VDC
Temperature Ambient: 14℉~122℉(-10℃~50℃) Ambient: 14℉~122℉(-10℃~50℃) Ambient: 14℉~122℉(-10℃~50℃) Ambient: 14℉~122℉(-10℃~50℃) Ambient: 14℉~122℉(-10℃~50℃) Ambient: 14℉~122℉(-10℃~50℃)
Fluid: 32℉~176℉(0℃~80℃) Fluid: 32℉~176℉(0℃~80℃) Fluid: 32℉~140℉(0℃~60℃) Fluid: 32℉~140℉(0℃~60℃) Fluid: 32℉~176℉(0℃~80℃) Fluid: 32℉~176℉(0℃~80℃)
Transmitter PC/ABS,IP65. NEMA 4X (IP65), Die-cast IP54 IP54 PC/ABS,IP65. NEMA 4X (IP65), Die-cast
Transducer Encapsulated design,IP68 aluminum
Encapsulated design,IP68 Clamp on Clamp on Encapsulated design,IP68. aluminum
Encapsulated design
Transducer  Standard cable length:30ft(9m). Standard/maximum cable φ5 six core cable, standard length: φ5 six core cable, standard length: Standard cable length:30ft(9m). Standard/maximum cable
cable length:30ft/1000ft(9m/305m) 2m 2m length:30ft/1000ft(9m/305m)
Features Clamp-on Transducers; Clamp-on Transducers; Cloud Data Storage System Cloud Data Storage System Clamp-on Transducers; Clamp-on Transducers;
Fixed-mounted meter; Fixed-mounted meter; Fixed-mounted meter; Fixed-mounted meter;
Clound service; Clound service; Clound service; Clound service;
Heat measurement Heat measurement; High temp. version available
High temp. version available High temp. version available
Product View
www.pflow.com.cn

QUALITY CONTROL
CALIBRATION

Axial double-loop flow calibration device adopts 3488D Heat meter flow calibration system can be used to
multipath ultrasonic flow meter as a master meter. The calibrate the hot (cold) flowmeter DN15~DN50, the
master meter takes our PICOFLY technology, the measuring medium temperature which can be
resolution has reached 0.01 nanoseconds, realize single maintained at 50 ℃ + 5℃.
point repeatability of 0.04%.

DN100 axial flow calibration device is mainly used in Liquid Flow calibration device adopts weighing method
volume production product calibration, the calibration to calibrate, suitable for flowmeter in DN8 ~ DN80.
device can be inspection 6 sets flowmeter at the same
time.

HIGH-TEMP AGING WORK


In 55 centigrade high temperature environment at
least 72 hours to make the high-temp aging work .
Gentos Measurement & Control Co., Ltd.
12/F, Block A5. Nanshan Ipark, No.1001 College Rd.
Nanshan District. Shenzhen CHINA
Tel: 86-755-26745561
Fax: 86-755-26745333
E-mail: [email protected] Find our website with Google search: www.pflowmeters.com

You might also like