0% found this document useful (0 votes)
185 views1 page

Datasheet 4kw-15kw 3ph - 2021

This document provides specifications for three-phase solar inverters with power ratings ranging from 4KW to 15KW. It lists technical details such as maximum DC and AC power levels, efficiency ratings, environmental tolerances, dimensions, connectors, communication capabilities, certifications and warranty information. The inverters are designed for outdoor use, come with surge protection and remote monitoring, and are warranted for 5 to 10 years.

Uploaded by

Eureka Solar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
185 views1 page

Datasheet 4kw-15kw 3ph - 2021

This document provides specifications for three-phase solar inverters with power ratings ranging from 4KW to 15KW. It lists technical details such as maximum DC and AC power levels, efficiency ratings, environmental tolerances, dimensions, connectors, communication capabilities, certifications and warranty information. The inverters are designed for outdoor use, come with surge protection and remote monitoring, and are warranted for 5 to 10 years.

Uploaded by

Eureka Solar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Three Phase

Model (KSY) (KW) 4 5 6 7 8 10 12 15


Input (DC)
Max Peak DC Input Power (KW) 5.2 6.5 7.8 9.1 10.4 12 15.6 16.5
Max. DC I/P (V dc) 1000 VDC 1000 VDC
Max. MPPT I/P Current(A) 10A*2 11A+22A 10/20A
MPPT Short Circuit Current(A) 10A+10A 10A+20A 22A
MPPT Tracking Voltage(Vdc) 200-850V 200-850V
Min. Start Voltage(V) 250 VDC 250 VDC
Number of MPPT Tracker 2 2
strings per MPPT Trackers 1 2/1 2
Output (AC)
Rated output power (KW) 4 5 6 7 8 10 12 15
Rated Grid Voltage(V) 400 VAC 400Vac
Nominal Grid freq.(Hz) 50Hz 50 Hz
Max. output current AC(A ) 6.4 7.2 8.7 10.1 11.6 14.5 17.4 21.17
AC Connec on (With PE) 3P + N + E 3P + N + E
THD (%) <5% <5%
Output Power factor(%) >0.99% >0.99%
Efficiency
Max. conversion eff. (%) 98% 97
Max. Euro Efficiency(%) 97.50% 98.5
Max. MPPT Eficiency (%) >99% >99%
Physical Parameters
Dimensions(LXWXH) mm 453.39x385x177.13 520x400x240
Weight (Kg) 18 18
Enclosure Color PANTONE Cool Grey 3 C Panton cool grey 3C
Color Thickness 100-250µ (micron) 100-250µ (Micron)
General Data
Opera ng Temperature - 25 ° to + 60° - 25 ° to + 60°

Opera ng Surrounding Humidity 0-100% 0-100%

Design Life Over 25 years Over 25 years


Night Con. (W)/Noise Level <1W/<30dB <1W/<30dB

Heat Dissipa on Natural Convec on inteligent Forced Cooling + Natural Convec on

0% to 98%. No Condensa on/<2000 without


RH/Max. Al tude 0% to 98%. No Condensa on/<2000 without power dera ng
power dera ng
Display Graphical -LED with LCD Display Graphical -LED with LCD Display
DC /AC Connectors (IP-65) MC-4 MC-4
WiFi/GPRS/RS 485/RS 232/ETHERNET LAN/ Local
Communica on interface WiFi/GPRS/RS 485/RS 232/ETHERNET LAN/ Local Monitoring
Monitoring
Standard Warranty 5 Years ( extendable upto 10 Year) 5/ 7 Years upto 10 Years extendable
Standards, Safety & Protec ons
DC Switch Including Including
SPD (surge Protec on Device) Type-3 SPD With GDT/op onal Type-3 SPD With GDT
MPPT Efficiency IEC 61683 IEC 61683
Inverter Efficiency IEC 61683 IEC 61683
Over Voltage Category IEC 62109-1 IEC 62109-1
Safety Standard IEC 62109-1&2 IEC 62109-1&2
EMC Standard IEC61000-6-1/2/3/4 IEC61000-6-1/2/3/4
Emnvironment Protec on IEC 60068-2-1/2/14/15 IEC 60068-2-1/2/14/15
An -Islanding IEC-62116 IEC-62116
Ingress Protec on IP 65 IP 65

PV Ligh ning,DC input short circuit,DC O/V & U/V,Insula on Resistance detec on,RCCB/ELCB, Output Over /Under
voltage,Outpur Over current, Output Over/Under frequency, Over temerature,GDI for input & Output, SPD as per
Protec on & Safety
requirement Type-1&2, AC output PF control,AC output power control by using external limiter for zero export
protec on,Defined remote Grid monitoring se ng & An -Islanding.