Code Failure Liugong CLG922EII
Code Failure Liugong CLG922EII
Do the following tests when the engine is running and shuts down, respectively.
If the excavator operates in a closed space, be sure to discharge the exhaust gases before starting
the engine to maintain the excavator.
No irrelevant personnel is allowed to be close to the excavator working and detection area.
Some tests may be required to be done when the excavator is travelling. Therefore, before starting
any test, make sure the driver has been trained specially and has been qualified.
Notice: Some tests may require the appropriate hearing protection devices.
Some tests may need the help of the specialized testing tools. Therefore, before starting any test,
make sure the operators understand these tools fully.
Before performing any of the following tests, make sure all routine examination items have been
completed.
Start the engine and do the testing by following the relevant guidance steps. When detecting the
hydraulic system components, make sure that the hydraulic system has been fully heated and all
hydraulic components have reached normal operating temperature.
6-9
CLG922E 6.2 Basic fault detection before maintenance
February 3, 2015
6.4 DTC
6.4.1 DTC 101001 Extremely low battery voltage
System description
When the alternator does not work or generates a low voltage, the battery supplies power to the electrical
equipment. When the engine starts, the battery supplies power to the starter motor. When the engine is
started, the battery is charged by the alternator. When the electrical equipment needs more power simulta-
neously and the alternator is overloaded, the battery assists the alternator to supply power. The battery has
a rated voltage of 12V. The complete excavator is powered by two batteries in series.
6-14
6.4 DTC CLG922E
6.4.1 DTC 101001 Extremely low battery voltage February 3, 2015
6-15
CLG922E 6.4 DTC
February 3, 2015 6.4.1 DTC 101001 Extremely low battery voltage
Component location
Front
Battery
Be sure to turn off the electric lock before checking whether the battery cables are secured
reliably.
• Inspection method
Turn the battery terminals by hand or with the tools, and check them for looseness.
Visually check the terminals for rust.
• Whether the battery terminals become loose or rusty or not?
• Yes
Tighten or derust.
Turn to Step 6
• No
Turn to Step 2
6-16
6.4 DTC CLG922E
6.4.1 DTC 101001 Extremely low battery voltage February 3, 2015
Figure
Alternator
Start motor
6-20
6.4 DTC CLG922E
6.4.2 DTC 101003 High battery voltage February 3, 2015
System description
When the alternator does not work or generates a low voltage, the battery supplies power to the electrical
equipment. When the engine starts, the battery supplies power to the starter motor. When the engine is
started, the battery is charged by the alternator. When the electrical equipment needs more power simulta-
neously and the alternator is overloaded, the battery assists the alternator to supply power. The battery has
a rated voltage of 12V. The complete excavator is powered by two batteries in series.
6-21
CLG922E 6.4 DTC
February 3, 2015 6.4.2 DTC 101003 High battery voltage
6-22
6.4 DTC CLG922E
6.4.2 DTC 101003 High battery voltage February 3, 2015
• Yes
Repair or replace the battery.
Turn to Step 3
• No
Turn to Step 2
Battery
Figure
Alternator
6-24
6.4 DTC CLG922E
6.4.3 DTC 101017 Low battery voltage February 3, 2015
System description
When the alternator does not work or generates a low voltage, the battery supplies power to the electrical
equipment. When the engine starts, the battery supplies power to the starter motor. When the engine is
started, the battery is charged by the alternator. When the electrical equipment needs more power simulta-
neously and the alternator is overloaded, the battery assists the alternator to supply power. The battery has
a rated voltage of 12V. The complete excavator is powered by two batteries in series.
6-25
CLG922E 6.4 DTC
February 3, 2015 6.4.3 DTC 101017 Low battery voltage
6-26
6.4 DTC CLG922E
6.4.3 DTC 101017 Low battery voltage February 3, 2015
when the engine is running: Connect the multimeter probes to both ends
of the charging harness
dures:
1. Stop the engine and check whether the alter-
nator belt becomes loose.
2. Start the engine, and measure the voltage
between the alternator terminal B and the
grounding with the multimeter (normally, higher
than the battery voltage).
• Whether the alternator fails or its output
Connect the red probe to Connect the black voltage is low?
the generator B+ probe to ground
• Yes
1. Tension or replace the drive belt.
2. Contact your local authorized LiuGong dealer
• Whether the charging harness is open-
or service center.
circuited or not (the coupling ends
become loose)? Turn to Step 6
• No
• Yes
Turn to Step 5
Repair the harness or re-connect it.
Turn to Step 6
Step 5 Check whether the controller power volt-
• No
age is too low.
Turn to Step 4
During the detection period, turn the
Step 4 Check whether the alternator fails or its start switch to the OFF position
output voltage is low. • Inspection method
Pay special attention to the following 1. Check the controller power line for wear and
the coupling ends for looseness.
when the engine is running:
2. Turn the multimeter to its DC voltage function
1. Hot engine block can scald you seriously.
(200V), and measure the voltage between the
2. Prevent the harnesses, clothing and oth-
controller power terminal (J1-2, J1-3, J1-4, J1-5,
ers from being drawn into the belts and the
J1-6) and the grounding, respectively.
flywheel.
3. Do not let the excavator move.
• Inspection method
After the engine is started, there are two pos-
sible causes for the alternator fault:
1. The belt is too loose.
2. Alternator fault
• Check the battery in the following proce-
6-29
CLG922E 6.4 DTC
February 3, 2015 6.4.3 DTC 101017 Low battery voltage
Figure
Alternator
Start motor
Controller J2(White)
Alternator
Battery charging
indicator switch
Start moter
GND
6-31
CLG922E 6.4 DTC
February 3, 2015 6.4.4 DTC 111001 System charging fault
1. Check the connector pins for looseness, rust, (b) Turn the multimeter to its resistance func-
bending and damage. tion, and measure the resistance of the har-
2. Turn the multimeter to its resistance function, ness between the connector (J2-2)
and measure the resistance between the oil connected to the controller and the switch
pressure switch connector terminals 1 and 2 (normally, <10Ω).
(normally, <10Ω). • Is the harness open?
• Whether a fault developing in the oil • Yes
pressure switch or not? Connect the harness again and wrap the har-
• Yes ness.
Repair or replace the oil pressure switch. Turn to Step 4
Turn to Step 4 • No
• No Turn to Step 3
Turn to Step 2
6-35
CLG922E 6.4 DTC
February 3, 2015 6.4.5 DTC 121015 Engine oil pressure switch OFF
J1 (Black)
Controller
Hand pilot
pressure switch Hand pilot
pressure switch
J2(White)
Foot pedal
pressure switch
Foot pilot
pressure switch
6-39
CLG922E 6.4 DTC
February 3, 2015 6.4.7 DTC 121305 Hand pilot pressure switch OFF
Component location
Front
Foot pilot
pressure switch Connect the multimeter probes to
two pins of the hand pilot pressure
Hand pilot pressure switch switch, respectively.
• Inspection method
Connect the hand pilot pressure switch connec-
tor and disconnect the controller connector.
Turn the multimeter to its resistance function,
Gray wire and measure the resistance between the har-
ness at the controller port J1-8 and the ground-
Red probe
Connect the harness again and wrap the har- Turn to Step 4
6-41
CLG922E 6.4 DTC
February 3, 2015 6.4.7 DTC 121305 Hand pilot pressure switch OFF
J1 (Black)
Controller
Hand pilot
pressure switch Hand pilot
pressure switch
J2(White)
Foot pedal
pressure switch
Foot pilot
pressure switch
6-43
CLG922E 6.4 DTC
February 3, 2015 6.4.8 DTC 121405 Foot pilot pressure switch OFF
Component location
Front
Foot pilot
pressure switch Connect the multimeter probes to
two pins of the foot pilot pressure
Hand pilot pressure switch switch, respectively.
• Inspection method
Connect the foot pilot pressure switch connector
and disconnect the controller connector. Turn
the multimeter to its resistance function, and
Gray wire measure the resistance between the harness at
the controller port J2-13 and the grounding (nor-
Red probe
mally, <10Ω).
J2(White)
Controller
J2(White)
Controller
Component location Step 2 Check the air filter monitoring system for
fault.
J1(Black)
Controller
Engine speed
J2(White)
Speed sensor
Sensor to ground
6-52
6.4 DTC CLG922E
6.4.11 DTC 131000 High engine speed February 3, 2015
When replacing the components, please When replacing the components, please
be sure to use LiuGong parts. be sure to use LiuGong parts.
• Inspection method • Inspection method
Check whether the operator’s operating method Check the speed detection circuit or speed sen-
is correct. sor for fault in accordance with the fault diagno-
• Whether the operating method is correct sis of the 131005 - Engine Speed Sensor Fault.
or not. • Check whether a fault developing in the
• Yes detection circuit speed sensor or not?
Tell the operator about the correct operating • Yes
method. Repair the detection circuit or replace the speed
Turn to Step 4 sensor.
• No Turn to Step 4
Turn to Step 2 • No
Turn to Step 4
6-53
CLG922E 6.4 DTC
February 3, 2015 6.4.11 DTC 131000 High engine speed
J1(Black)
Controller
Engine speed
J2(White)
Speed sensor
Sensor to ground
6-55
CLG922E 6.4 DTC
February 3, 2015 6.4.12 DTC 131005 Engine speed sensor fault
Speed sensor
Front
Correctly tie up harness and wire:
• Yes • Yes
Tighten or repair, or replace the speed sensor. Connect the harness again and wrap the har-
Turn to Step 4 ness.
Turn to Step 4
• No
Turn to Step 2 • No
Turn to Step 3
6-56
6.4 DTC CLG922E
6.4.12 DTC 131005 Engine speed sensor fault February 3, 2015
Temperature sensor
Controller
Coolant temperature
Sensor to ground
6-58
6.4 DTC CLG922E
6.4.13 DTC 131100 Extremely high coolant temperature February 3, 2015
Temperature sensor
Controller
Coolant temperature
Sensor to ground
Resistance (Ohm)
6-60
6.4 DTC CLG922E
6.4.14 DTC 131103 Coolant temperature sensor voltage above the range value February 3, 2015
J1(Black)
Controller
Coolant temperature
Hydraulic oil
temperature
Temperature sensor
J2(White)
Sensor to ground
Resistance (Ohm)
6-63
CLG922E 6.4 DTC
February 3, 2015 6.4.15 DTC 131104 Coolant temperature sensor voltage below the range value
Temperature sensor
Controller
Coolant temperature
Sensor to ground
6-66
6.4 DTC CLG922E
6.4.16 DTC 131115 High coolant temperature February 3, 2015
Temperature sensor
Controller
Coolant temperature
Sensor to ground
6-68
6.4 DTC CLG922E
6.4.17 DTC 131116 High coolant temperature February 3, 2015
Sensor to ground
6-70
6.4 DTC CLG922E
6.4.18 DTC 1131200 Extremely high hydraulic oil temperature February 3, 2015
Front
When replacing the components, please
be sure to use LiuGong parts.
• Inspection method
If the hydraulic oil temperature is normal, check
the hydraulic oil temperature detection circuit or
hydraulic oil temperature sensor for fault in
accordance with the fault diagnosis of 131203 -
Hydraulic Oil Temperature Sensor Voltage
Hydraulic oil
temperature sensor Above the Range Value.
• Whether a fault developing in the
hydraulic oil temperature monitoring
Fault diagnosis and elimination pro-
system or not?
cedures
• Yes
Step 1 Check whether the hydraulic oil tempera-
Repair the hydraulic oil temperature detection
ture is extremely high.
circuit or replace the hydraulic oil temperature
Be careful! Hot engine block and sensor.
hydraulic oil can scald you seriously Turn to Step 3
• Inspection method • No
Sensor to ground
Resistance (Ohm)
6-72
6.4 DTC CLG922E
6.4.19 DTC 131203 Hydraulic oil temperature sensor voltage above the range value February 3, 2015
Sensor to ground
Resistance (Ohm)
6-75
CLG922E 6.4 DTC
February 3, 2015 6.4.20 DTC 131204 Hydraulic oil temperature sensor voltage below the range value
Front
Correctly tie up harness and wire:
Sensor to ground
6-78
6.4 DTC CLG922E
6.4.21 DTC 131215 High hydraulic oil temperature February 3, 2015
Front
When replacing the components, please
be sure to use LiuGong parts.
• Inspection method
If the hydraulic oil temperature is normal, check
the hydraulic oil temperature detection circuit or
hydraulic oil temperature sensor for fault in
accordance with the fault diagnosis of 131203 -
Hydraulic Oil Temperature Sensor Voltage
Hydraulic oil
temperature sensor Above the Range Value.
• Whether a fault developing in the
hydraulic oil temperature monitoring
Fault diagnosis and elimination pro-
system or not?
cedures
• Yes
Step 1 Check whether the hydraulic oil tempera-
Repair the hydraulic oil temperature detection
ture is too high
circuit or replace the hydraulic oil temperature
Be careful! Hot engine block and sensor.
hydraulic oil can scald you seriously Turn to Step 3
• Inspection method • No
Sensor to ground
6-80
6.4 DTC CLG922E
6.4.22 DTC 131216 Extremely high hydraulic oil temperature February 3, 2015
Front
When replacing the components, please
be sure to use LiuGong parts.
• Inspection method
If the hydraulic oil temperature is normal, check
the hydraulic oil temperature detection circuit or
hydraulic oil temperature sensor for fault in
accordance with the fault diagnosis of 131203 -
Hydraulic Oil Temperature Sensor Voltage Out-
Hydraulic oil
temperature sensor side the Range Value.
• Whether a fault developing in the
hydraulic oil temperature monitoring
Fault diagnosis and elimination pro-
system or not?
cedures
• Yes
Step 1 Check whether the hydraulic oil tempera-
Repair the hydraulic oil temperature detection
ture is extremely high.
circuit or replace the hydraulic oil temperature
Be careful! Hot engine block and sensor.
hydraulic oil can scald you seriously Turn to Step 3
• Inspection method • No
Controller J2(White)
Fuel level
Fuel level sensor
6-82
6.4 DTC CLG922E
6.4.23 DTC 131303 Fuel level sensor voltage above the range value February 3, 2015
Fuel level sensor parameter table 2. Turn the multimeter to its resistance function,
and measure the resistance between the fuel
(For the details, see the figure.)
level sensor connector terminals 1 and 2 (nor-
Component location mally, <2K, for the specific resistance, see the
figure.).
Front
• Inspection method
1. Check the harness (No. 930) and the ground-
ing wire (No.227) between the controller (J2-30)
and fuel level sensor for wear.
2. Disconnect the connectors from the fuel level
sensor and the controller.Check the harness for
open-circuit:
White wire
(a) Turn the multimeter to its resistance func-
tion, and measure the resistance between
the grounding wire (No.227) sensor termi- To the black probe
Oil level
6-86
6.4 DTC CLG922E
6.4.24 DTC 131304 Fuel level sensor shorted to the ground February 3, 2015
Controller J2(White)
Fuel level
Fuel level sensor
6-87
CLG922E 6.4 DTC
February 3, 2015 6.4.24 DTC 131304 Fuel level sensor shorted to the ground
Fuel level sensor parameter table 1. Check the connector for moisture, oil dirt and
other
(For the details, see the figure.)
2. Turn the multimeter to its resistance function
Component location (2K), and measure the resistance between the
fuel level sensor terminals 1 and 2 (normally,
Front
>10Ω, for the specific resistance, see the figure).
It shall be kept away from moving compo- When replacing the components, please
nents as far as possible to prevent tensile be sure to use LiuGong parts.
fault and wear.
• Inspection method
Avoid friction with sharp metal edges.
Connect the sensor connector and disconnect
Try to keep far way from oil and water. the controller connector. Turn the multimeter to
Try to keep far away from high temperature its resistance function, and measure the resis-
parts (e.g. engine body). tance between the J2-30 port and the grounding
• Inspection method (normally, >10Ω).
1. Check the harness (No. 930) between the When the resistance is abnormal, this indi-
controller (J2-30) and fuel level sensor for wear. cates there is an insulation fault in the con-
2. Disconnect the connectors from the fuel level nector
sensor and the controller. Turn the multimeter to • Whether a fault developing in the con-
its resistance function, and measure the resis- nector or not?
tance between the harness (No. 930) sensor ter- • Yes
minal and the grounding (normally, >100K).
Replace the connector.
Turn to Step 4
• No
Turn to Step 4
Oil level
6-90
6.4 DTC CLG922E
6.4.25 DTC 131317 Low fuel level February 3, 2015
Controller J2(White)
Fuel level
Fuel level sensor
6-91
CLG922E 6.4 DTC
February 3, 2015 6.4.25 DTC 131317 Low fuel level
Fuel level sensor parameter table Step 2 Check the fuel level monitoring system
for fault.
(For the details, see the figure.)
Component location When replacing the components, please
be sure to use LiuGong parts.
• Inspection method
Front
If the fuel level is normal, check the fuel level
monitoring system in accordance with the fault
diagnosis in the 131304 - Fuel Level Sensor
Shorted to the Ground.
• Whether a fault developing in the fuel
level monitoring system or not?
• Yes
Fuel level sensor
Repair or replace the fuel level sensor.
Turn to Step 3
• No
Fault diagnosis and elimination pro-
Turn to Step 3
cedures
Step 1 Check whether the fuel level is low.
Step 3 Check whether this fault is eliminated
• Inspection method
• Inspection method
Check the fuel level.
Turn the start switch to the ON position and re-
• Whether the fuel level is low or not? check for fault.
• Yes • Has this fault been eliminated?
Add fuel. • Yes
Turn to Step 3 Maintenance is over
• No • No
Turn to Step 2 Troubleshoot the faults according to the steps
again or contact the local LiuGong dealer and
authorized service center.
6-92
6.4 DTC CLG922E
6.4.25 DTC 131317 Low fuel level February 3, 2015
Oil level
6-93
CLG922E 6.4 DTC
February 3, 2015 6.4.26 DTC 131603 Water-in-fuel sensor voltage above the range value
Controller J2(White)
Water-in-fuel
sensor
Water-in-fuel sensor
6-94
6.4 DTC CLG922E
6.4.26 DTC 131603 Water-in-fuel sensor voltage above the range value February 3, 2015
Fuel-in-water
Try to keep far away from high temperature
sensor
parts (e.g. engine body).
• Inspection method
Fault diagnosis and elimination pro- 1. Check the harness (No. 921) and the ground-
cedures ing wire (No. 254) between the controller (J2-21)
and the water-in-fuel sensor for wear.
Step 1 Check the water-in-fuel sensor for fault.
2. Disconnect the connectors from the water-in-
When replacing the components, please fuel sensor and the controller. Check the har-
be sure to use LiuGong parts. ness for open-circuit:
• Inspection method (a) Turn the multimeter to its resistance func-
Turn the start switch to the OFF position, tion, and measure the resistance between
and disconnect the connector from the the grounding wire (No.254) sensor termi-
water-in-fuel sensor. nal and the grounding (normally, <10Ω).
1. Check the connector for looseness, rust, (b) Turn the multimeter to its resistance func-
bending and damage. tion, and measure the resistance of har-
2. Turn the multimeter to its resistance function, ness between the connector ports J2-21
and measure the resistance between the water- and sensor (normally, <10Ω).
in-fuel sensor connector terminals 1 and 2 (nor- • Is the harness open?
mally, <4.6M/306.5K). • Yes
• Whether a fault developing in the water- Connect the harness again and wrap the har-
in-fuel sensor or not? ness.
• Yes Turn to Step 4
Repair or replace the water-in-fuel sensor. • No
Turn to Step 4 Turn to Step 3
• No
Turn to Step 2
6-95
CLG922E 6.4 DTC
February 3, 2015 6.4.26 DTC 131603 Water-in-fuel sensor voltage above the range value
Controller J2(White)
Water-in-fuel
sensor
Water-in-fuel sensor
6-97
CLG922E 6.4 DTC
February 3, 2015 6.4.27 DTC 131604 Water-in-fuel sensor voltage below the range value
Front
Correctly tie up harness and wire:
Controller J2(White)
Water-in-fuel
sensor
Water-in-fuel sensor
6-100
6.4 DTC CLG922E
6.4.28 DTC 131605 Water-in-fuel sensor open-circuited February 3, 2015
Fuel-in-water
Try to keep far away from high temperature
sensor
parts (e.g. engine body).
• Inspection method
Fault diagnosis and elimination pro- 1. Check the harness (No. 921) and the ground-
cedures ing wire (No. 254) between the controller (J2-21)
and the water-in-fuel sensor for wear.
Step 1 Check the water-in-fuel sensor for fault.
2. Disconnect the connectors from the water-in-
When replacing the components, please fuel sensor and the controller. Check the har-
be sure to use LiuGong parts. ness for open-circuit:
• Inspection method (a) Turn the multimeter to its resistance func-
Turn the start switch to the OFF position, tion, and measure the resistance between
and disconnect the connector from the the grounding wire (No.254) sensor termi-
water-in-fuel sensor. nal and the grounding (normally, <10Ω).
1. Check the connector for looseness, rust, (b) Turn the multimeter to its resistance func-
bending and damage. tion, and measure the resistance of har-
2. Turn the multimeter to its resistance function, ness between the connector ports J2-21
and measure the resistance between the water- and sensor (normally, <10Ω).
in-fuel sensor connector terminals 1 and 2 (nor- • Is the harness open?
mally, <4.6M). • Yes
• Whether a fault developing in the water- Connect the harness again and wrap the har-
in-fuel sensor or not? ness.
• Yes Turn to Step 4
Repair or replace the water-in-fuel sensor. • No
Turn to Step 4 Turn to Step 3
• No
Turn to Step 2
6-101
CLG922E 6.4 DTC
February 3, 2015 6.4.28 DTC 131605 Water-in-fuel sensor open-circuited
Controller J2(White)
Water-in-fuel
sensor
Water-in-fuel sensor
6-103
CLG922E 6.4 DTC
February 3, 2015 6.4.29 DTC 131615 Water-in-fuel
Front
When replacing the components, please
be sure to use LiuGong parts.
• Inspection method
If the fuel is normal, check the water-in-fuel
detection circuit or the water-in-fuel sensor for
fault in accordance with the fault diagnosis in the
131604- Water-in-Fuel Sensor Voltage Below
the Range Value or 131603 - Water-in-Fuel
Fuel-in-water
sensor Sensor Voltage Above the Range Value.
• Whether a fault developing in the water-
in-fuel monitoring system or not?
Fault diagnosis and elimination pro-
• Yes
cedures
Repair the water-in-fuel detection circuit or
Step 1 Check the fuel for water.
replace the water-in-fuel sensor.
• Inspection method Turn to Step 3
Check the oil-water separator for water. • No
• Whether water in the fuel or not? Turn to Step 3
• Yes
Drain the water in the fuel. Step 3 Check whether this fault is eliminated
Turn to Step 3 • Inspection method
• No Turn the start switch to the ON position and re-
Turn to Step 2 check for fault.
• Has this fault been eliminated?
• Yes
Maintenance is over
• No
Troubleshoot the faults according to the steps
again or contact the local LiuGong dealer and
authorized service center.
6-104
6.4 DTC CLG922E
6.4.30 DTC 131703 Sensor power (5V) shorted to the battery February 3, 2015
Accelerator knob
Controller J1 (Black)
Accelerator motor 2 (ls ac2)
5V power supply
12-position throttle
potentiometer Accelerator actuato
Accelerator motor 1 (ls ac1)
J2(White)
Accelerator motor 2 (hs ac2)
cedures • No
Troubleshoot the faults according to the steps
Step 1 Check the sensor power (5V) is shorted
again or contact the local LiuGong dealer and
to the battery.
authorized service center.
Correctly tie up harness and wire:
Accelerator knob
Controller J1 (Black)
Accelerator motor 2 (ls ac2)
5V power supply
12-position throttle
potentiometer Accelerator actuato
Accelerator motor 1 (ls ac1)
J2(White)
Accelerator motor 2 (hs ac2)
Step 1 Check the accelerator knob or actuator Try to keep far away from high temperature
for fault. parts (e.g. engine body).
• Inspection method
When replacing the components, please
1. Check the harnesses (No. 828 and No. 922)
be sure to use LiuGong parts.
between the controllers (J1-28 and J2-22) and
• Inspection method the accelerator knob or actuator for wear,
Turn the start switch to the OFF position and respectively.
disconnect the connectors from the acceler- 2. Disconnect the accelerator knob, the acceler-
ator knob and actuator: ator actuator connector and the controller con-
1. Check the connector for moisture, oil dirt and nector. Turn the multimeter to its resistance
other function, and measure the resistance between
2. Turn the multimeter to its resistance function, the terminal opposite to the harness (No. 828/
and measure the resistance between the accel- No. 922) controller and the grounding, respec-
erator knob connector terminals 1 and 2 (nor- tively (normally, >100K).
mally, >10Ω). • Whether the harness is shorted to the
3. Measure the resistance between the termi- ground or not?
nals 3 and 5 of the accelerator actuator connec- • Yes
tor (normally, >10Ω).
Connect the harness again and wrap the har-
• Whether a fault developing in the accel- ness.
erator knob or actuator or not? Turn to Step 4
• Yes • No
Repair or replace the accelerator knob and the Turn to Step 3
6-108
6.4 DTC CLG922E
6.4.31 DTC 131704 Sensor power (5V) shorted to the ground February 3, 2015
Step 3 Check the connector for fault. Step 4 Check whether this fault is eliminated
be sure to use LiuGong parts. Turn the start switch to the ON position and re-
check for fault.
• Inspection method
• Has this fault been eliminated?
1. Connect the accelerator knob connector and
disconnect the accelerator actuator and the con- • Yes
troller connector. Turn the multimeter to its resis- Maintenance is over
tance function, and measure the resistance • No
between the controller ports J1-28 and J2-22 Troubleshoot the faults according to the steps
(normally, >10Ω). again or contact the local LiuGong dealer and
2. Connect the accelerator actuator connector authorized service center.
and disconnect the accelerator knob and the
controller connector. Turn the multimeter to its
resistance function, and measure the resistance
between the controller port J1-28 and J2-22
(normally, >10Ω).
When the resistance in any step above is
abnormal, this indicates an insulation fault
develops in the connector.
• Whether a fault developing in the con-
nector or not?
• Yes
Replace the connector.
Turn to Step 4
• No
Turn to Step 4
6-109
CLG922E 6.4 DTC
February 3, 2015 6.4.32 DTC 141005 Pump proportional solenoid valve feedback open-circuited
Pump proprtional
solenoid valve
Pump solenoid valve current
Main pump PWM signal
Pump solenoid valve current feedback
6-110
6.4 DTC CLG922E
6.4.32 DTC 141005 Pump proportional solenoid valve feedback open-circuited February 3, 2015
Step 1 Check the pump proportional solenoid 1. Check the harness (No. 905/No. 901)
valve for fault. between the controller and the pump propor-
tional solenoid valve for wear.
When replacing the components, please
2. Disconnect the connectors from the pump
be sure to use LiuGong parts. proportional solenoid valve and the controller,
• Inspection method respectively. Turn the multimeter to its resis-
Turn the start switch to the OFF position and tance function, and measure the resistance of
disconnect the pump proportional solenoid the harness (No. 905/No. 901) between the con-
valve: troller and the solenoid valve, respectively (nor-
mally, <10Ω).
1. Check the connector for looseness, rust,
bending and damage. • Is the harness open?
2. Turn the multimeter to its resistance function, • Yes
and measure the resistance between the sole- Connect the harness again and wrap the har-
noid valve connector terminals 1 and 2 (nor- ness.
mally, 16-40Ω). Turn to Step 4
• Whether a fault developing in the pump • No
proportional solenoid valve or not? Turn to Step 3
• Yes
Repair or replace the pump proportional sole-
noid valve.
Turn to Step 4
• No
6-111
CLG922E 6.4 DTC
February 3, 2015 6.4.32 DTC 141005 Pump proportional solenoid valve feedback open-circuited
Pump proprtional
solenoid valve
Pump solenoid valve current
Main pump PWM signal
Pump solenoid valve current feedback
6-113
CLG922E 6.4 DTC
February 3, 2015 6.4.33 DTC 141006 Pump proportional solenoid valve feedback overcurrent
• Yes • Yes
Repair or replace the pump proportional sole- Connect the harness again and wrap the har-
noid valve. ness.
• No • No
6-114
6.4 DTC CLG922E
6.4.33 DTC 141006 Pump proportional solenoid valve feedback overcurrent February 3, 2015
Turn to Step 3
Pump proprtional
solenoid valve
Pump solenoid valve current
Main pump PWM signal
Pump solenoid valve current feedback
6-116
6.4 DTC CLG922E
6.4.34 DTC 141104 Pump proportional solenoid valve shorted to the ground February 3, 2015
Description of
DTC Consequence
Fault
Pump proportional
solenoid valve
The engine
141105 open-circuited or
gets stuck.
shorted to the
battery
Pump proprtional
solenoid valve
Pump solenoid valve current
Main pump PWM signal
Pump solenoid valve current feedback
6-119
CLG922E 6.4 DTC
February 3, 2015 6.4.35 DTC 141105 Pump proportional solenoid valve open-circuited or shorted to the battery
Fault diagnosis and elimination pro- Try to keep far away from high temperature
parts (e.g. engine body).
cedures
• Inspection method
Step 1 Check the pump proportional solenoid
valve for fault. 1. Check the harness (No. 905/No. 901)
between the controller and the pump propor-
When replacing the components, please tional solenoid valve for wear.
be sure to use LiuGong parts. Disconnect the connectors from the pump pro-
• Inspection method portional solenoid valve and the controller.
Turn the start switch to the OFF position and 2. Check whether the harness is shorted to the
disconnect the pump proportional solenoid battery. Turn the start switch to the ON position
valve: and switch on the switches of all electrical
1. Check the connector for looseness, rust, equipment, and then measure the voltage
bending and damage. between the harness (No. 901 and No. 905)
solenoid valve terminal and the grounding (nor-
2. Turn the multimeter to its resistance function,
mally, 0V).
and measure the resistance between the sole-
noid valve connector terminals 1 and 2 (nor- 3. Check the harnesses for open-circuit. Turn
mally, 16-40Ω). the multimeter to its resistance function, and
measure the resistance of the harnesses (No.
• Whether a fault developing in the pump
905 and No. 901) between the controller and the
proportional solenoid valve or not?
solenoid valve, respectively (normally, < 10Ω).
• Yes
• Whether the harness open-circuited or
Repair or replace the pump proportional sole-
shorted to the battery or not?
noid valve.
• Yes
Turn to Step 4
Connect the harness again and wrap the har-
• No
ness.
6-120
6.4 DTC CLG922E
6.4.35 DTC 141105 Pump proportional solenoid valve open-circuited or shorted to the battery February 3, 2015
Turn to Step 4
• No
Turn to Step 3
Controller
Fault diagnosis and elimination pro- Try to keep far away from high temperature
parts (e.g. engine body).
cedures
• Inspection method
Step 1 Check the attachment confluent solenoid
valve for fault. 1. Check the harness (No. 912) between the
controller (J2-12) and the attachment confluent
When replacing the components, please solenoid valve for wear.
be sure to use LiuGong parts. 2. Disconnect the connectors from attachment
• Inspection method confluent solenoid valve and the controller. Turn
Turn the start switch to the OFF position and the multimeter to its resistance function, and
disconnect the attachment confluent sole- measure the resistance between the harness
noid valve connector: (No. 912) solenoid valve terminal and the
grounding (normally, >100K).
1. Check the connector for moisture, oil dirt and
other • Whether the harness is shorted to the
2. Turn the multimeter to its resistance function, ground or not?
and measure the resistance between the attach- • Yes
ment confluent solenoid connector terminals 1 Connect the harness again and wrap the har-
and 2 (normally, 16-40Ω). ness.
• Whether a fault developing in the attach- Turn to Step 4
ment confluent solenoid valve or not? • No
• Yes Turn to Step 3
Repair or replace the attachment confluent sole-
noid valve.
Turn to Step 4
• No
6-123
CLG922E 6.4 DTC
February 3, 2015 6.4.36 DTC 151004 Attachment confluent solenoid valve shorted to the ground
Description of
DTC Consequence
Fault
Attachment
confluent solenoid
There is no
valve open-
151005 hydraulic shear
circuited or
function.
shorted to the
battery
Controller
Fault diagnosis and elimination pro- Try to keep far away from high temperature
parts (e.g. engine body).
cedures
• Inspection method
Step 1 Check the attachment confluent solenoid
valve for fault. 1. Check the harness (No. 912) or the grounding
wire (No. 252) between the controller and the
When replacing the components, please attachment confluent solenoid valve for wear.
be sure to use LiuGong parts. Disconnect the connectors from the attachment
• Inspection method confluent solenoid valve and the controller.
Turn the start switch to the OFF position and 2. Check whether the harness is shorted to the
disconnect the attachment confluent sole- battery. Turn the start switch to the ON position
noid valve connector: and turn on all switches of the electrical equip-
ment, and then measure the voltage between
1. Check the connector for looseness, rust,
the harness (No. 912) solenoid valve terminal
bending and damage.
and the grounding (normally, 0V).
2. Turn the multimeter to its resistance function,
3. Check the harness for open-circuit. Turn the
and measure the resistance between the attach-
multimeter to its resistance function, and mea-
ment confluent solenoid valve connector termi-
sure the resistance of the harness (No. 912)
nals 1 and 2 (normally, 16-40Ω).
between the controller and the solenoid valve
• Whether a fault developing in the attach-
and that of the harness (No. 252) between the
ment confluent solenoid valve or not?
solenoid valve and the grounding (normally,
• Yes <10Ω).
Repair or replace the attachment confluent sole- • Whether the harness open-circuited or
noid valve. shorted to the battery or not?
Turn to Step 4
• Yes
• No
Connect the harness again and wrap the har-
6-126
6.4 DTC CLG922E
6.4.37 DTC 151005 Attachment confluent solenoid valve open-circuited or shorted to the battery February 3, 2015
Description of
DTC Consequence
Fault
Travel speed
There is no
solenoid valve
151204 travel speed
shorted to the
function.
ground.
Controller
Travel speed solenoid valve (valve A2)
A2 Travel speed
solenoid valve
6-128
6.4 DTC CLG922E
6.4.38 DTC 151204 A2 Travel speed solenoid shorted to the ground February 3, 2015
Figure
Definition of
connector pin
serial number
Controller
Controller connector
Front
Description of
DTC Consequence
Fault
There is no
travel speed
A2 travel speed
function or the
solenoid valve
travel speed
151205 open-circuited or
solenoid valve
shorted to the
is uncontrolled
battery.
by the
controller.
Controller
Travel speed solenoid valve (valve A2)
A2 Travel speed
solenoid valve
6-131
CLG922E 6.4 DTC
February 3, 2015 6.4.39 DTC 151205 A2 Travel speed solenoid open-circuited or shorted to the battery
1. Check the pins for looseness, rust, bending (b) Turn the multimeter to its resistance func-
and damage. tion, and measure the resistance between
the grounding wire (No.222) travel speed
2. Measure the resistance between both ends of
solenoid valve terminal and the grounding
the travel speed solenoid valve. The resistance
(normally, <10Ω).
should be 16-40Ω.
• Is there a fault in track shift solenoid?
• Yes
Repair or replace the travel speed solenoid
valve.
Turn to Step 5
• No
Turn to Step 2
6-132
6.4 DTC CLG922E
6.4.39 DTC 151205 A2 Travel speed solenoid open-circuited or shorted to the battery February 3, 2015
• No
Definition of Turn to Step 4
connector pin
serial number
Figure
Controller
Controller connector
Front
6-134
6.4 DTC CLG922E
6.4.40 DTC 151304 A3 Flattening solenoid valve shorted to the ground February 3, 2015
Description of
DTC Consequence
Fault
Flattening solenoid There is no
151304 valve shorted to flattening
the ground function.
Controller
Flattening solenoid valve (valve A3)
A3 arm speed
2nd gear proportional
solenoid valve
6-135
CLG922E 6.4 DTC
February 3, 2015 6.4.40 DTC 151304 A3 Flattening solenoid valve shorted to the ground
Component location Step 2 Check whether the power line of the flat-
tening solenoid valve is shorted to the ground.
Figure
Definition of
connector pin
serial number
Controller
Controller connector
Front
tery
Description of
DTC Consequence
Fault
There is no
flattening
A3 Flattening
function or the
solenoid valve
flattening
151305 open-circuited or
solenoid valve
shorted to the
is uncontrolled
battery.
by the
controller.
Controller
Flattening solenoid valve (valve A3)
A3 arm speed
2nd gear proportional
solenoid valve
6-138
6.4 DTC CLG922E
6.4.41 DTC 151305 A3 Flattening solenoid valve open-circuited or shorted to the battery February 3, 2015
• No
Definition of Turn to Step 4
connector pin
serial number
Figure
Controller
Controller connector
Front
6-141
CLG922E 6.4 DTC
February 3, 2015 6.4.42 DTC 151404 A8 Digging solenoid valve shorted to the ground
Description of
DTC Consequence
Fault
Digging solenoid There is no
151404 valve shorted to digging
the ground. function.
Controller
Digging solenoid valve (valve A8)
A8 Digging solenoid valve
6-142
6.4 DTC CLG922E
6.4.42 DTC 151404 A8 Digging solenoid valve shorted to the ground February 3, 2015
Component location Step 2 Check whether the power line of the dig-
ging solenoid valve is shorted to the ground.
Figure
Definition of
connector pin
serial number
Controller
Controller connector
Front
Description of
DTC Consequence
Fault
The digging
Digging solenoid
solenoid valve
valve open-
is open-
151405 circuited or
circuited or in
shorted to the
the digging
battery.
function state.
Controller
Digging solenoid valve (valve A8)
A8 Digging solenoid valve
6-145
CLG922E 6.4 DTC
February 3, 2015 6.4.43 DTC 151405 A8 Digging solenoid valve open-circuited or shorted to the battery
1. Check the pins for looseness, rust, bending (b) Turn the multimeter to its resistance func-
and damage. tion, and measure the resistance between
2. Measure the resistance between both ends of the grounding wire (No.225) digging sole-
the digging solenoid valve. The resistance noid valve terminal and the grounding (nor-
should be 16-40Ω. mally, <10Ω).
• No
Definition of Turn to Step 4
connector pin
serial number
Figure
Controller
Controller connector
Front
6-148
6.4 DTC CLG922E
6.4.44 DTC 151504 A5 Flow adjusting solenoid shorted to the ground February 3, 2015
Controller
• Inspection method
Connect the flow adjusting solenoid valve con-
nector and disconnect the controller connector.
Turn the multimeter to its resistance function,
and measure the resistance between the har-
ness at the controller port J2-8 and the ground- Controller connector
Controller
1. Check the pins for looseness, rust, bending (b) Turn the multimeter to its resistance func-
and damage. tion, and measure the resistance between
2. Measure the resistance between both ends of the feedback wire (No.924) flow adjusting
the flow adjusting solenoid valve. The resistance solenoid valve terminal and the grounding
should be 16-40Ω. (normally, <10Ω).
• No
Definition of Turn to Step 4
connector pin
serial number
• Whether a fault in the connector or not? Troubleshoot the faults according to the steps
again or contact the local LiuGong dealer and
• Yes
authorized service center.
Replace the connector.
Turn to Step 5
6-154
6.4 DTC CLG922E
6.4.45 DTC 151505 A5 Flow adjusting solenoid valve open-circuited or shorted to the battery February 3, 2015
Figure
Controller
Controller connector
Front
6-155
CLG922E 6.4 DTC
February 3, 2015 6.4.46 DTC 151605 A6 Flow adjusting solenoid open-circuited or shorted to the battery
Controller
1. Check the pins for looseness, rust, bending (b) Turn the multimeter to its resistance func-
and damage. tion, and measure the resistance between
2. Measure the resistance between both ends of the feedback wire (No.924) flow adjusting
the flow adjusting solenoid valve. The resistance solenoid valve terminal and the grounding
should be 16-40Ω. (normally, <10Ω).
• No
Definition of Turn to Step 4
connector pin
serial number
Figure
Controller
Controller connector
Front
6-159
CLG922E 6.4 DTC
February 3, 2015 6.4.47 DTC 151704 A7 Transient power boosting solenoid valve shorted to the ground
Description of
DTC Consequence
Fault
Transient power
There is no
boosting solenoid
151704 power boosting
valve shorted to
function.
the ground.
Controller
Transient power bossting solenoid valve valve A7
A7 Transient power
boosting solenoid
valve
6-160
6.4 DTC CLG922E
6.4.47 DTC 151704 A7 Transient power boosting solenoid valve shorted to the ground February 3, 2015
• Inspection method • No
Turn the start switch to the OFF position and Turn to Step 3
disconnect the connector from the power
boosting solenoid valve. Step 3 Check the connector for fault
1. Check the pins for moisture, oil dirt and other. Shutdown operation is needed.
2. Measure the resistance between both ends of
the power boosting solenoid valve. The resis- When replacing the components, please
tance should be 16-40Ω. be sure to use LiuGong parts.
• Whether the power boosting solenoid • Inspection method
valve for fault? Connect the power boosting solenoid valve con-
• Yes nector and disconnect the controller connector.
Repair or replace the power boosting solenoid Turn the multimeter to its resistance function,
valve. and measure the resistance between the har-
Turn to Step 4 ness at the controller port J1-13 and the ground-
ing (normally, 16-40Ω). When the resistance is
• No
abnormal, this indicates there is a fault in the
Turn to Step 2
connector.
6-161
CLG922E 6.4 DTC
February 3, 2015 6.4.47 DTC 151704 A7 Transient power boosting solenoid valve shorted to the ground
Figure
Definition of
connector pin
serial number
Controller
Controller connector
Front
battery
Description of
DTC Consequence
Fault
Transient power
There is no
boosting solenoid
power boosting
valve open-
151705 or the power
circuited or
boosting is
shorted to the
kept.
battery.
Controller
Transient power bossting solenoid valve valve A7
A7 Transient power
boosting solenoid
valve
6-163
CLG922E 6.4 DTC
February 3, 2015 6.4.48 DTC 151705 A7 Transient power boosting solenoid valve open-circuited or shorted to the battery
• No
Definition of Turn to Step 4
connector pin
serial number
• Whether a fault in the connector or not? Troubleshoot the faults according to the steps
again or contact the local LiuGong dealer and
• Yes
authorized service center.
Replace the connector.
Turn to Step 5
6-165
CLG922E 6.4 DTC
February 3, 2015 6.4.48 DTC 151705 A7 Transient power boosting solenoid valve open-circuited or shorted to the battery
Figure
Controller
Controller connector
Front
6-166
6.4 DTC CLG922E
6.4.49 DTC 151804 A4 Travel lifting solenoid valve shorted to the ground February 3, 2015
Description of
DTC Consequence
Fault
Travel lifting
There is no
solenoid valve
151804 travel lifting
shorted to the
function.
ground.
• Inspection method • No
Turn the start switch to the OFF position and Turn to Step 3
disconnect the connector from the travel lifting
solenoid valve. Step 3 Check the connector for fault
1. Check the pins for moisture, oil dirt and other.
Shutdown operation is needed.
2. Measure the resistance between both ends of
the travel lifting solenoid valve. The resistance When replacing the components, please
should be 16-40Ω. be sure to use LiuGong parts.
• Whether a fault developing in the travel • Inspection method
lifting solenoid valve. Connect the travel lifting solenoid valve connec-
• Yes tor and disconnect the controller connector.
Repair or replace the travel speed solenoid Turn the multimeter to its resistance function,
valve. and measure the resistance between the har-
Turn to Step 4 ness at the controller port J1-26 and the ground-
ing (normally, 16-40Ω). When the resistance is
• No
abnormal, this indicates there is a fault in the
Turn to Step 2
connector.
6-168
6.4 DTC CLG922E
6.4.49 DTC 151804 A4 Travel lifting solenoid valve shorted to the ground February 3, 2015
Figure
Definition of
connector pin
serial number
Controller
Controller connector
Front
Description of
DTC Consequence
Fault
There is no
travel lifting
Travel lifting
function or the
solenoid valve
travel lifting
151805 open-circuited or
solenoid valve
shorted to the
is uncontrolled
battery.
by the
controller.
1. Check the pins for looseness, rust, bending (b) Turn the multimeter to its resistance func-
and damage. tion, and measure the resistance between
2. Measure the resistance between both ends of the grounding wire (No. 223) travel lifting
the travel lifting solenoid valve. The resistance solenoid valve terminal and the grounding
should be 16-40Ω. (normally, <10Ω).
• No
Definition of Turn to Step 4
connector pin
serial number
Figure
Controller
Controller connector
Front
6-173
CLG922E 6.4 DTC
February 3, 2015 6.4.51 DTC 151905 A5 or A6 solenoid valve feedback open-circuited
Description of
DTC Consequence
Fault
A5 or A6 flow
adjusting solenoid The flow cannot
151905
valve open- be adjusted.
circuited.
Controller
Component location
Definition of
connector pin
serial number
Solenoid valve
assembly. Both
A5-marked solenoid
and A6-marked
solenoid can be
located
Front
Try to keep far way from oil and water. • Inspection method
Try to keep far away from high temperature Check the connectors between the A5/A6 flow
parts (e.g. engine body). adjusting solenoid valve for looseness and their
pins for rust, bending and damage one by one
• Inspection method
manually.
Turn the start switch to the OFF position,
Disconnect the controller connector and connect
Disconnect the connectors from the controller
the connector of A5 and A6 flow adjusting sole-
(in the figure), A5 and A6 flow adjusting solenoid
noid valves, and then measure the resistance
valves, and measure the resistance between the
among the controller connector ports J2-8, J2-9
J2-24 wire and the A5/A6 flow adjusting sole-
and J2-24. The resistance should be 16-40Ω.
noid valve. The maximum resistance should be
Otherwise, there is a fault in the connector.
10Ω.
• Whether a fault in the connector or not?
• Yes
Adjust or replace the connector.
Turn to Step 3
6-175
CLG922E 6.4 DTC
February 3, 2015 6.4.51 DTC 151905 A5 or A6 solenoid valve feedback open-circuited
• No
Turn to Step 3
Figure
Controller
Controller connector
Front
6-176
6.4 DTC CLG922E
6.4.52 DTC 151906 A5 or A6 solenoid valve feedback overcurrent February 3, 2015
Description of
DTC Consequence
Fault
A5 or A6 solenoid
The flow cannot
151906 valve feedback
be adjusted.
overcurrent.
Controller
Definition of
connector pin
Fault diagnosis and elimination pro- serial number
cedures
Step 1 Check the pump proportional solenoid
for fault
• Inspection method
Turn the start switch to the OFF position, and
check the pins for moisture, oil dirt and other.
Measure the resistance of A5 or A6 flow adjust- • Whether the harness is shorted to the
ing solenoid valve. The resistance should be 16- battery or not?
40Ω.
• Yes
• Whether a fault developing in the pump
Re-connect the harness, and wrap it.
proportional solenoid valve or not?
Turn to Step 4
• Yes
• No
Replace solenoid valve
Turn to Step 3
Turn to Step 4
• No
Turn to Step 2
6-178
6.4 DTC CLG922E
6.4.52 DTC 151906 A5 or A6 solenoid valve feedback overcurrent February 3, 2015
• Inspection method
Check the connectors between the A5/A6 flow Controller
• No
Turn to Step 4
Battery
IPC Controller
Battery relay
6-180
6.4 DTC CLG922E
6.4.53 DTC 171004 Battery relay shorted to the ground February 3, 2015
Ignition switch
Battery
Preheating relay K3
Controller
Preheating relay
6-183
CLG922E 6.4 DTC
February 3, 2015 6.4.54 DTC 171104 Auto preheating relay shorted to the ground
Component location
K9 auto preheating
relay. It can be pulled
out during detection`
6-184
6.4 DTC CLG922E
6.4.54 DTC 171104 Auto preheating relay shorted to the ground February 3, 2015
Fault diagnosis and elimination pro- Step 2 Check the connectors for fault
• Yes
Re-connect the harness, and wrap it.
Turn to Step 3
• No
Turn to Step 2
6-185
CLG922E 6.4 DTC
February 3, 2015 6.4.54 DTC 171104 Auto preheating relay shorted to the ground
Figure
Controller
Controller connector
Front
6-186
6.4 DTC CLG922E
6.4.55 DTC 171105 Auto preheating relay open-circuited or shorted to the battery February 3, 2015
Ignition switch
Battery
Preheating relay K3
Controller
Preheating relay
6-187
CLG922E 6.4 DTC
February 3, 2015 6.4.55 DTC 171105 Auto preheating relay open-circuited or shorted to the battery
Component location
K9 auto preheating
relay. It can be pulled
out during detection`
Fault diagnosis and elimination pro- supply (24V), and measure the terminals 30 and
87 by turning the multimeter to its on-off func-
cedures
tion. The relay should switch on.
Step 1 Check the auto preheating relay for fault.
• Whether a fault developing in the auto
When replacing the components, please preheating relay or not?
be sure to use LiuGong parts. • Yes
• Inspection method Replace the auto preheating relay.
For troubleshooting, turn the start switch to the Turn to Step 4
OFF position. No
Open the fuse box, and pull out the auto pre- Turn to Step 2
heating relay.
Measure the resistance between the ports 85
and 86 of the auto preheating relay coil. The
resistance should be 320-360Ω.
Connect the terminals 85 and 86 to the power
6-188
6.4 DTC CLG922E
6.4.55 DTC 171105 Auto preheating relay open-circuited or shorted to the battery February 3, 2015
Avoid folding or bending the harness forci- Step 3 Check the connectors for fault
bly
When replacing the components, please
Avoid friction with sharp metal edges
be sure to use LiuGong parts.
Try to keep far way from oil and water
• Inspection method
Try to keep far away from high temperature
Insert the auto preheating relay into the fuse box
parts (e.g. engine body) as far as possible
properly and disconnect the controller connec-
• Inspection method
tor, and then turn the multimeter to its resistance
For troubleshooting, turn the start switch to the function and measure the resistance between
OFF position. the harness at the controller port J2-11 and the
Disconnect the connector from the controller (in grounding. The resistance should be between
the figure) and pull out the auto preheating 320-360Ω. Otherwise, check the connector:
relay, and then measure the resistance between
(a) Check the connector at the grounding of
the harness (No. 911) at the J2-11 port and the
the relay for poor contact:
auto preheating relay. The maximum resistance
(b) Check the connector of the relay for loose-
should be 10Ω.
ness or damage.
Measure the resistance between the 85 port in
• Whether a fault in the connector or not?
the fuse box and the ground. The maximum
resistance should be 10Ω. • Yes
Adjust or replace the connector.
Turn to Step 4
Definition of
connector pin
serial number • No
Turn to Step 4
Figure
Controller
Controller connector
Front
6-190
6.4 DTC CLG922E
6.4.56 DTC 171204 Start cut-off relay shorted to the ground February 3, 2015
Controller
Component location
Fault diagnosis and elimination pro- Connect the terminals 85 and 86 to the power
supply (24V), and measure the terminals 30 and
cedures
87 by turning the multimeter to its on-off func-
Step 1 Check whether there is a fault in the start
tion. The relay should switch on.
cut-off relay.
• Check if there is a fault in the start cut-
When replacing the components, please off valve relay.
be sure to use LiuGong parts. • Yes
• Inspection method Replace the start cut-off valve relay.
For troubleshooting, turn the start switch to the Turn to Step 4
OFF position: • No
Open the fuse box, and pull out the auto pre- Turn to Step 2
heating relay;
Measure the resistance between the ports 85
and 86 of the start cut-off relay coil. The resis-
tance should be 320-350Ω.
6-192
6.4 DTC CLG922E
6.4.56 DTC 171204 Start cut-off relay shorted to the ground February 3, 2015
connector pin
Shutdown operation is needed serial number
• Inspection method
1. Turn the start switch to the OFF position for
fault diagnosis.
2.Disconnect the connectors from the controller
(in the figure) and the start cut-off relay, and
measure the resistance between the power line
(No. 923) of the start cut-off relay and the
grounding. The resistance should be infinite.
• Whether the power line of the start cut- • Whether a fault in the connector or not?
off relay is shorted to the ground or not. • Yes
• Yes Replace the connector.
Re-connect the harness, and wrap it. Turn to Step 4
Turn to Step 4 • No
• No Turn to Step 4
Turn to Step 3
Step 4 Check whether this fault is eliminated
Step 3 Check the connectors for fault • Inspection method
Shutdown operation is needed. Turn the start switch to the ON position and re-
check the DTC.
When replacing the components, please
• Has this fault been eliminated?
be sure to use LiuGong parts.
• Yes
• Inspection method
Maintenance is over
Connect the connector of the start cut-off relay
• No
and disconnect the controller connector, and
Troubleshoot the faults according to the steps
then turn the multimeter to its resistance func-
again or contact the local LiuGong dealer and
tion and measure the resistance between the
authorized service center.
harness at the controller port J2-23 and the
grounding (normally, 320-350Ω). If the resis-
tance is abnormal, this indicates that there is a
fault in the connector.
6-193
CLG922E 6.4 DTC
February 3, 2015 6.4.56 DTC 171204 Start cut-off relay shorted to the ground
Figure
Controller
Controller connector
Front
6-194
6.4 DTC CLG922E
6.4.57 DTC 171205 Start cut-off output open-circuited or shorted to the battery February 3, 2015
Controller
Component location
Fault diagnosis and elimination pro- parts (e.g. engine body) as far as possible
Step 1 Check whether there is a fault in the start For troubleshooting, turn the start switch to the
cut-off relay. OFF position:
Disconnect the connector from the controller (in
When replacing the components, please
the figure) and pull out the start cut-off relay, and
be sure to use LiuGong parts. then measure the resistance between the har-
• Inspection method ness (No. 923) at the J2-23 port and the start
For troubleshooting, turn the start switch to the cut-off relay. The maximum resistance should
OFF position: be 10Ω.
Open the fuse box, and pull out the start cut-off Measure the resistance between the 85 port in
relay. the fuse box and the ground. The maximum
Measure the resistance between the ports 85 resistance should be 10Ω.
and 86 of the start cut-off relay coil. The resis-
tance should be 320-360Ω. Definition of
connector pin
Connect the terminals 85 and 86 to the power serial number
Step 3 Check the connectors for fault • Whether the start cut-off relay is shorted
to the battery or not?
When replacing the components, please
be sure to use LiuGong parts. • Yes
Find out the short circuit position and re-connect
• Inspection method
the harness and wrap it.
Insert the start cut-off relay into the fuse box
Turn to Step 5
properly and disconnect the controller connec-
tor, and then turn the multimeter to its resistance • No
function and measure the resistance between Turn to Step 5
the harness (No. 923) at the controller port J2-
23 and the grounding. The resistance should be Step 5 Check whether this fault is eliminated
between 320-360Ω. Otherwise, check the con- • Inspection method
nector:
Turn the start switch to the ON position and re-
(a) Check the connector at the grounding of check the DTC.
the start cut-off relay for poor contact.
• Has this fault been eliminated?
(b) Check the connector of the start cut-off
• Yes
relay for looseness or damage.
Maintenance is over
• Whether a fault in the connector or not?
• No
• Yes
Troubleshoot the faults according to the steps
Adjust or replace the connector. again or contact the local LiuGong dealer and
Turn to Step 5 authorized service center.
• No
Turn to Step 4 Figure
(Black)
Controller
Component location
Front
Travel alarm
6-199
CLG922E 6.4 DTC
February 3, 2015 6.4.58 DTC 201004 Travel alarm shorted to the ground
Fault diagnosis and elimination pro- controller connector. Turn the multimeter to its
resistance function, and measure the resistance
cedures
between the harness (No. 801) sensor terminal
Step 1 Check the travel Alarm for fault.
and grounding (normally, >100K).
When replacing the components, please • Whether the harness is shorted to the
be sure to use LiuGong parts. ground or not?
• Inspection method • Yes
Turn the start switch to the OFF position, Connect the harness again and wrap the har-
and disconnect the travel alarm connector. ness.
1. Check the connector for moisture, oil dirt and Turn to Step 4
other. • No
2. Turn the multimeter to its resistance function, Turn to Step 3
and measure the resistance between the alarm
connector terminals 1 and 2 (normally, >10Ω). Step 3 Check the connector for fault.
• Check the travel Alarm for fault.
When replacing the components, please
• Yes
be sure to use LiuGong parts.
Repair or replace the sensor.
• Inspection method
Turn to Step 4
Connect the attachment confluent solenoid
• No
valve attachment connector and disconnect the
Turn to Step 2
controller connector. Turn the multimeter to its
resistance function, and measure the resistance
Step 2 Check the harness for short-circuit to between the controller port J1-01 and the
ground grounding (normally, >10Ω).
Shutdown operation is needed When the resistance is abnormal, this indicates
there is an insulation fault in the connector.
Correctly tie up harness and wire:
• Whether a fault developing in the con-
Avoid folding or bending the harness forci- nector or not?
bly • Yes
Avoid friction with sharp metal edges Replace the connector.
Try to keep far way from oil and water Turn to Step 4
Try to keep far away from high temperature • No
parts (e.g. engine body) as far as possible
Turn to Step 4
• Inspection method
1. Check the harness (No. 801) between the
controller (J1-01) and the travel alarm for wear.
2. Disconnect the travel alarm connector and the
6-200
6.4 DTC CLG922E
6.4.58 DTC 201004 Travel alarm shorted to the ground February 3, 2015
Controller J2(White)
P1 Left pump pressure transmitter
P1 left pump pressure
6-202
6.4 DTC CLG922E
6.4.59 DTC 211003 P1 pump pressure sensor voltage above the range value February 3, 2015
Step 3 Check the pump pressure sensor for connect the controller connector, and then dis-
fault. connect the pump pressure sensor connector
and measure the current in the pump pressure
When replacing the components, please
sensor signal circuit:
be sure to use LiuGong parts.
(a) Connect the measuring circuit as shown in
• Inspection method the schematic diagram.
Turn the start switch to the OFF position and
Controller J2(White)
Multimeter
(b) Start the engine, and with the boom lifted, Step 4 Check whether this fault is eliminated
turn the multimeter to its current function, • Inspection method
and measure the current between the sen- Turn the start switch to the ON position and re-
sor connector male terminal and female check for fault.
terminal (Pin 1) (normally, 4-20mA).
• Has this fault been eliminated?
• Whether a fault developing in the pump
• Yes
pressure or not?
Maintenance is over
• Yes
• No
Replace the pump pressure sensor.
Troubleshoot the faults according to the steps
Turn to Step 4
again or contact the local LiuGong dealer and
• No authorized service center.
Turn to Step 4
6-204
6.4 DTC CLG922E
6.4.60 DTC 211004 P1 pump pressure sensor voltage below the range value February 3, 2015
Controller J2(White)
P1 Left pump pressure transmitter
P1 left pump pressure
6-205
CLG922E 6.4 DTC
February 3, 2015 6.4.60 DTC 211004 P1 pump pressure sensor voltage below the range value
When replacing the components, please (a) Turn the multimeter to its voltage function,
and measure the voltage between the
be sure to use LiuGong parts.
power line (No. 121) sensor terminal and
• Inspection method the grounding (normally, 25±0.5V (battery
1. Check the connector at the sensor grounding voltage)).
for poor contact. (b) Turn the multimeter to its resistance func-
2. Check whether the connector becomes loose. tion, and measure the resistance of the har-
3. Check the connector pins for rust, bending or ness (No. 931) between the controller and
damage. the sensor (normally, <10Ω).
• Whether a fault developing in the con- 3. Check whether the harness is shorted to the
nector or not? ground:
• Yes Measure the resistance between the harness
Repair or replace the connector. (No. 931) sensor terminal and the grounding
Turn to Step 4 (normally, >100K).
Controller J2(White)
Multimeter
(b) Turn the multimeter to its current function Step 4 Check whether this fault is eliminated
(200mA) and start the engine, and then • Inspection method
with the boom lifted, measure the current Turn the start switch to the ON position and re-
between the sensor connector male termi- check for fault.
nal and female terminal (Pin 1) (normally,
• Has this fault been eliminated?
4-20mA).
• Yes
• Check the pump pressure sensor for
Maintenance is over
fault.
• No
• Yes
Troubleshoot the faults according to the steps
Replace the pump pressure sensor.
again or contact the local LiuGong dealer and
Turn to Step 4
authorized service center.
• No
Turn to Step 4
6-207
CLG922E 6.4 DTC
February 3, 2015 6.4.61 DTC 211003 P2 pump pressure sensor voltage above the range value
Controller J2(White)
P2 right pump pressure transmitter
P2 right pump pressure
6-208
6.4 DTC CLG922E
6.4.61 DTC 211003 P2 pump pressure sensor voltage above the range value February 3, 2015
Step 3 Check the pump pressure sensor for connect the controller connector, and then dis-
fault. connect the pump pressure sensor connector
and measure the current in the pump pressure
When replacing the components, please
sensor signal circuit:
be sure to use LiuGong parts.
(a) Connect the measuring circuit as shown in
• Inspection method the schematic diagram.
Turn the start switch to the OFF position and
Connector matching P2
P2 Left pump pressure transnmitter
Controller J2(White)
Multimeter
(b) Start the engine, and with the boom lifted, Step 4 Check whether this fault is eliminated
turn the multimeter to its current function, • Inspection method
and measure the current between the sen- Turn the start switch to the ON position and re-
sor connector male terminal and female check for fault.
terminal (Pin 1) (normally, 4-20mA).
• Has this fault been eliminated?
• Check the pump pressure sensor for
• Yes
fault.
Maintenance is over
• Yes
• No
Replace the pump pressure sensor.
Troubleshoot the faults according to the steps
Turn to Step 4
again or contact the local LiuGong dealer and
• No authorized service center.
Turn to Step 4
6-210
6.4 DTC CLG922E
6.4.62 DTC 211104 P2 pump pressure sensor voltage below the range value February 3, 2015
P2 pump pressure
sensor voltage
below the range
value. When the
left/right control
lever is operated,
No special
211104 the current
response.
detected in the
signal circuit of the
P2 pump pressure
sensor is
extremely low
(below 4mA).
Controller J2(White)
P2 right pump pressure transmitter
P2 right pump pressure
6-211
CLG922E 6.4 DTC
February 3, 2015 6.4.62 DTC 211104 P2 pump pressure sensor voltage below the range value
When replacing the components, please (a) Turn the multimeter to its voltage function,
and measure the voltage between the
be sure to use LiuGong parts.
power line (No. 121) sensor terminal and
• Inspection method the grounding (normally, 25±0.5V (battery
1. Check the connector at the sensor grounding voltage)).
for poor contact. (b) Turn the multimeter to its resistance func-
2. Check whether the connector becomes loose. tion, and measure the resistance of the har-
3. Check the connector pins for rust, bending or ness (No. 932) between the controller and
damage. the sensor (normally, <10Ω).
• Whether a fault developing in the con- 3. Check whether the harness is shorted to the
nector or not? ground:
• Yes Measure the resistance between the harness
Repair or replace the connector. (No. 932) sensor terminal and the grounding
Turn to Step 4 (normally, >100K).
Connect the harness again and wrap the har- When replacing the components, please
ness.
be sure to use LiuGong parts.
Turn to Step 4
• Inspection method
• No
Turn the start switch to the OFF position and
Turn to Step 3
disconnect the pump pressure sensor connec-
tor, and then connect the controller connector:
Step 3 Check the pump pressure sensor for
(a) Connect the current detection circuit as
fault.
shown in the schematic diagram:
Connector matching P2
P2 Left pump pressure transnmitter
Controller J2(White)
Multimeter
(b) Turn the multimeter to its current function Step 4 Check whether this fault is eliminated
(200mA) and start the engine, and then • Inspection method
with the boom lifted, measure the current Turn the start switch to the ON position and re-
between the sensor connector male termi- check for fault.
nal and female terminal (Pin 1) (normally,
• Has this fault been eliminated?
4-20mA).
• Yes
• Check the pump pressure sensor for
Maintenance is over
fault.
• No
• Yes
Troubleshoot the faults according to the steps
Replace the pump pressure sensor.
again or contact the local LiuGong dealer and
Turn to Step 4
authorized service center.
• No
Turn to Step 4
6-213
CLG922E 6.4 DTC
February 3, 2015 6.4.63 DTC 211203 N1 negative flow pressure sensor voltage above the range value
Controller J2(White)
N1 Negative flow N1 Negative flow pressure
pressure Left pump transmitter
6-214
6.4 DTC CLG922E
6.4.63 DTC 211203 N1 negative flow pressure sensor voltage above the range value February 3, 2015
Step 3 Check the N1 negative flow pressure sen- connect the controller connector, and then dis-
sor for fault. connect the N1 negative flow pressure sensor
connector and measure the current in the sen-
When replacing the components, please
sor signal circuit:
be sure to use LiuGong parts.
(a) Connect the measuring circuit as shown in
• Inspection method the schematic diagram.
Turn the start switch to the OFF position and
Connector matching P4
N1 Negative flow pressure transmitter
Controller J2(White)
Multimeter
(b) Start the engine, and with the boom lifted, Step 4 Check whether this fault is eliminated
turn the multimeter to its current function, • Inspection method
and measure the current between the sen- Turn the start switch to the ON position and re-
sor connector male terminal and female check for fault.
terminal (Pin 1) (normally, 4-20mA).
• Has this fault been eliminated?
• Check the N1 negative flow pressure
• Yes
sensor for fault.
Maintenance is over
• Yes
• No
Replace the N1 negative flow pressure sensor.
Troubleshoot the faults according to the steps
Turn to Step 4
again or contact the local LiuGong dealer and
• No authorized service center.
Turn to Step 4
6-216
6.4 DTC CLG922E
6.4.64 DTC 211204 N1 negative flow pressure sensor voltage below the range value February 3, 2015
Controller J2(White)
N1 Negative flow N1 Negative flow pressure
pressure Left pump transmitter
6-217
CLG922E 6.4 DTC
February 3, 2015 6.4.64 DTC 211204 N1 negative flow pressure sensor voltage below the range value
Connect the harness again and wrap the har- be sure to use LiuGong parts.
ness. • Inspection method
Turn to Step 4 Turn the start switch to the OFF position and
• No disconnect the N1 negative flow pressure sen-
Turn to Step 3 sor connector, and then connect the controller
Step 3 Check the N1 negative flow pressure connector:
sensor for fault. (a) Connect the current detection circuit as
shown in the schematic diagram:
When replacing the components, please
Connector matching P4
N1 Negative flow pressure transmitter
Controller J2(White)
Multimeter
(b) Turn the multimeter to its current function Step 4 Check whether this fault is eliminated
(200mA) and start the engine, and then • Inspection method
with the boom lifted, measure the current Turn the start switch to the ON position and re-
between the sensor connector male termi- check for fault.
nal and female terminal (Pin 1) (normally,
• Has this fault been eliminated?
4-20mA).
• Yes
• Check the N1 negative flow pressure
Maintenance is over
sensor for fault.
• No
• Yes
Troubleshoot the faults according to the steps
Replace the N1 negative flow pressure sensor.
again or contact the local LiuGong dealer and
Turn to Step 4
authorized service center.
• No
Turn to Step 4
6-219
CLG922E 6.4 DTC
February 3, 2015 6.4.65 DTC 211303 N2 negative flow pressure sensor voltage above the range value
Controller J2(White)
N2 Negative flow N2 Negative flow pressure
pressure right pump
transmitter
6-220
6.4 DTC CLG922E
6.4.65 DTC 211303 N2 negative flow pressure sensor voltage above the range value February 3, 2015
Step 3 Check the N2 negative flow pressure sen- connect the controller connector, and then dis-
sor for fault. connect the N2 negative flow pressure sensor
connector and measure the current in the sen-
When replacing the components, please
sor signal circuit:
be sure to use LiuGong parts.
(a) Connect the measuring circuit as shown in
• Inspection method the schematic diagram.
Turn the start switch to the OFF position and
Connector matching P3
N2 Negative flow pressure transmitter
Controller J2(White)
Multimeter
(b) Start the engine, and with the boom lifted, Step 4 Check whether this fault is eliminated
turn the multimeter to its current function, • Inspection method
and measure the current between the sen- Turn the start switch to the ON position and re-
sor connector male terminal and female check for fault.
terminal (Pin 1) (normally, 4-20mA).
• Has this fault been eliminated?
• Check the N2 negative flow pressure
• Yes
sensor for fault.
Maintenance is over
• Yes
• No
Replace the N2 negative flow pressure sensor.
Troubleshoot the faults according to the steps
Turn to Step 4
again or contact the local LiuGong dealer and
• No authorized service center.
Turn to Step 4
6-222
6.4 DTC CLG922E
6.4.66 DTC 211304 N2 negative flow pressure sensor voltage below the range value February 3, 2015
Controller J2(White)
N2 Negative flow N2 Negative flow pressure
pressure right pump
transmitter
6-223
CLG922E 6.4 DTC
February 3, 2015 6.4.66 DTC 211304 N2 negative flow pressure sensor voltage below the range value
Connector matching P3
N2 Negative flow pressure transmitter
Controller J2(White)
Multimeter
(b) Turn the multimeter to its current function Step 4 Check whether this fault is eliminated
(200mA) and start the engine, and then • Inspection method
with the boom lifted, measure the current Turn the start switch to the ON position and re-
between the sensor connector male termi- check for fault.
nal and female terminal (Pin 1) (normally,
• Has this fault been eliminated?
4-20mA).
• Yes
• Check the N2 negative flow pressure
Maintenance is over
sensor for fault.
• No
• Yes
Troubleshoot the faults according to the steps
Replace the N2 negative flow pressure sensor.
again or contact the local LiuGong dealer and
Turn to Step 4
authorized service center.
• No
Turn to Step 4
6-225
CLG922E 6.4 DTC
February 3, 2015 6.4.67 DTC 211316 High N2 negative flow pressure
Controller J2(White)
N2 Negative flow N2 Negative flow pressure
pressure right pump
transmitter
6-226
6.4 DTC CLG922E
6.4.67 DTC 211316 High N2 negative flow pressure February 3, 2015
Controller J2(White)
Pump valve pressure
Pump valve pressure transmitter
transmitter
6-228
6.4 DTC CLG922E
6.4.68 DTC 211403 Pump pressure-reducing valve sensor voltage above the range value February 3, 2015
Step 3 Check the pump pressure-reducing valve disconnect the connector from the pump pres-
sensor for fault. sure-reducing valve sensor, and then measure
the current of the signal circuit of the pump pres-
When replacing the components, please
sure-reducing valve sensor:
be sure to use LiuGong parts.
(a) Connect the measuring circuit as shown in
• Inspection method the schematic diagram.
Turn the start switch to the OFF position and
Connector matching P5
Pump valve pressure transmitter
Controller J2(White)
Pressure of pump proportional
pressure-reducing valve
Multimeter
(b) Start the engine, and with the boom lifted, Step 4 Check whether this fault is eliminated
turn the multimeter to its current function, • Inspection method
and measure the current between the sen- Turn the start switch to the ON position and re-
sor connector male terminal and female check for fault.
terminal (Pin 1) (normally, 4-20mA).
• Has this fault been eliminated?
• Whether a fault developing in the pump
• Yes
pressure-reducing valve sensor?
Maintenance is over
• Yes
• No
Replace the pump pressure-reducing valve sen-
Troubleshoot the faults according to the steps
sor.
again or contact the local LiuGong dealer and
Turn to Step 4
authorized service center.
• No
Turn to Step 4
6-230
6.4 DTC CLG922E
6.4.69 DTC 211404 Pump pressure-reducing valve sensor voltage below the range value February 3, 2015
Controller J2(White)
Pump valve pressure
Pump valve pressure transmitter
transmitter
6-231
CLG922E 6.4 DTC
February 3, 2015 6.4.69 DTC 211404 Pump pressure-reducing valve sensor voltage below the range value
Connector matching P5
Pump valve pressure transmitter
Controller J2(White)
Pressure of pump proportional
pressure-reducing valve
Multimeter
Accelerator knob
(Black)
(Black)
Accelerator motor 2 (ls ac2)
5V power supply
12-position accelerator
potentiometer
Accelerator actuator
Accelerator motor 1 (ls ac1)
(White)
Accelerator motor 2 (hs ac2)
Sensor to ground
6-234
6.4 DTC CLG922E
6.4.70 DTC 221001 Actuator feedback voltage below the range value February 3, 2015
• Yes Step 4
Connect the harness again and wrap the har- • Inspection method
ness. Turn the start switch to the ON position and re-
Turn to Step 4 check for fault.
• No • Has this fault been eliminated?
Turn to Step 3 • Yes
Maintenance is over
Step 3 Check the connector for fault. • No
When replacing the components, please Troubleshoot the faults according to the steps
be sure to use LiuGong parts. again or contact the local LiuGong dealer and
authorized service center.
• Inspection method
Connect the actuator connector and disconnect
the controller connector. Turn the multimeter to
its resistance function and measure the resis-
tance between the controller port J1-28 and J2-
18 (normally, 4-5kΩ), and then measure the
resistance between the ports J1-28 and J2-22
and that between the ports J2-28 and J2-22.
(The sum of the resistance between the pins 2
and 3 and that between the pins 2 and 5 equals
the resistance between the pins 3 and 5).
An abnormal resistance indicates that there is
fault in the connector.
• Whether a fault developing in the con-
nector or not?
• Yes
Replace the connector.
Turn to Step 4
No
Turn to Step 4
6-236
6.4 DTC CLG922E
6.4.71 DTC 221003 Actuator feedback voltage above the range value February 3, 2015
Accelerator knob
(Black)
(Black)
Accelerator motor 2 (ls ac2)
5V power supply
12-position accelerator
potentiometer
Accelerator actuator
Accelerator motor 1 (ls ac1)
(White)
Accelerator motor 2 (hs ac2)
Sensor to ground
6-237
CLG922E 6.4 DTC
February 3, 2015 6.4.71 DTC 221003 Actuator feedback voltage above the range value
Accelerator knob
(Black)
(Black)
Accelerator motor 2 (ls ac2)
5V power supply
12-position accelerator
potentiometer
Accelerator actuator
Accelerator motor 1 (ls ac1)
(White)
Accelerator motor 2 (hs ac2)
Sensor to ground
6-240
6.4 DTC CLG922E
6.4.72 DTC 221007 Actuator getting stuck February 3, 2015
Front
When replacing the components, please
be sure to use LiuGong parts.
• Inspection method
Turn the start switch to the OFF position, and
visually check whether the engine accelerator
flexible shaft (including its mounting plate)
becomes loose.
Accelerator actuator Start the excavator and turn the accelerator
knob, and then check whether the accelerator
flexible shaft is operating properly.
• Whether the accelerator actuator gets
Fault diagnosis and elimination pro-
stuck?
cedures
• Yes
Step 1 Check the harness connector for fault.
Repair or replace the accelerator actuator.
When replacing the components, please Turn to Step 3
be sure to use LiuGong parts. • No
• Inspection method Turn to Step 3
Check the harness connector for looseness.
Check the harness connector pins for rust, Step 3 Check whether this fault is eliminated
bending and damage. • Inspection method
There is moisture, oil dirt or insulation fault in the Turn the start switch to the ON position and re-
connector. check for fault.
• Whether a fault developing in the con- • Has this fault been eliminated?
nector or not?
• Yes
• Yes
Maintenance is over
Re-connect or replace the connector.
• No
Turn to Step 3
Troubleshoot the faults according to the steps
• No again or contact the local LiuGong dealer and
Turn to Step 2 authorized service center.
6-241
CLG922E 6.4 DTC
February 3, 2015 6.4.73 DTC 221013 Actuator outside the calibrated range
Accelerator knob
(Black)
(Black)
Accelerator motor 2 (ls ac2)
5V power supply
12-position accelerator
potentiometer
Accelerator actuator
Accelerator motor 1 (ls ac1)
(White)
Accelerator motor 2 (hs ac2)
Sensor to ground
6-242
6.4 DTC CLG922E
6.4.73 DTC 221013 Actuator outside the calibrated range February 3, 2015
Front
be sure to use LiuGong parts.
• Inspection method
1. Check the sensor for looseness.
2. Disconnect the speed sensor connector:
(a) Check the connector pins for looseness,
rust, bending and damage. Check the con-
nector inside for moisture, oil dirt and other.
Accelerator actuator
(b) Start the engine and turn the knob to
increase the accelerator gradually. Turn the
multimeter to its voltage function, and mea-
Fault diagnosis and elimination pro- sure the voltage on the sensor output ports
(normally, when the engine speed at 1000-
cedures
2270r/min, the speed sensor outputs an AC
Step 1 Check whether the number of teeth of the
voltage between 3-28V.).
flywheel is correct.
• Whether a fault developing in the speed
When replacing the components, please sensor or not?
be sure to use LiuGong parts. • Yes
• Inspection method Tighten or repair, or replace the speed sensor.
Check whether the number of teeth of the fly- Turn to Step 6
wheel is correct in the control parameter. • No
• Whether the number of teeth of the fly- Turn to Step 3
wheel is correct or not?
• Yes
Re-adjust the number of teeth of the flywheel in
the control parameter.
Turn to Step 6
• No
Turn to Step 2
6-243
CLG922E 6.4 DTC
February 3, 2015 6.4.73 DTC 221013 Actuator outside the calibrated range
Step 3 Check the harness for short-circuit to Step 4 Check whether the harness is open-cir-
ground cuited or shorted to the battery.
Correctly tie up harness and wire: Correctly tie up harness and wire:
Avoid folding or bending the harness forci- Avoid folding or bending the harness forci-
bly. bly.
It shall be kept away from moving compo- It shall be kept away from moving compo-
nents as far as possible to prevent tensile nents as far as possible to prevent tensile
fault and wear. fault and wear.
Avoid friction with sharp metal edges. Avoid friction with sharp metal edges.
Try to keep far way from oil and water. Try to keep far way from oil and water.
Try to keep far away from high temperature Try to keep far away from high temperature
parts (e.g. engine body). parts (e.g. engine body).
• Inspection method • Inspection method
1. Check the harness (No. 918) between the Disconnect the connectors from the accelerator
controller (J2-18) and the accelerator actuator actuator and the controller.
for wear. 1. Check the harness for open-circuit: Turn the
2. Disconnect the connectors from the accelera- multimeter to its resistance function, and mea-
tor actuator and the controller, respectively. sure the resistance of the harness (No. 918)
Turn the multimeter to its resistance function, between the controller and the actuator (nor-
and then measure the resistance between the mally, <10Ω).
harness (No. 918) actuator terminal and the 2. Check whether the harness is shorted to the
grounding (normally, >100K). battery. Turn the start switch to the ON position
• Whether the harness is shorted to the and turn on all switches of the electrical equip-
ground or not? ment, and then measure the voltage between
the harness (No. 918) actuator terminal and the
• Yes
grounding (normally, 0V).
Connect the harness again and wrap the har-
• Whether the harness open-circuited or
ness.
shorted to the battery or not?
Turn to Step 6
• Yes
• No
Connect the harness again and wrap the har-
Turn to Step 4
ness.
Turn to Step 6
• No
Turn to Step 5
6-244
6.4 DTC CLG922E
6.4.73 DTC 221013 Actuator outside the calibrated range February 3, 2015
Accelerator knob
(Black)
(Black)
Accelerator motor 2 (ls ac2)
5V power supply
12-position accelerator
potentiometer
Accelerator actuator
Accelerator motor 1 (ls ac1)
(White)
Accelerator motor 2 (hs ac2)
Sensor to ground
6-246
6.4 DTC CLG922E
6.4.74 DTC 221104 Actuator AC1 terminal shorted to the ground February 3, 2015
Front
Correctly tie up harness and wire:
Accelerator knob
(Black)
(Black)
Accelerator motor 2 (ls ac2)
5V power supply
12-position accelerator
potentiometer
Accelerator actuator
Accelerator motor 1 (ls ac1)
(White)
Accelerator motor 2 (hs ac2)
Sensor to ground
6-249
CLG922E 6.4 DTC
February 3, 2015 6.4.75 DTC 221204 Actuator AC2 terminal shorted to the ground
Front
Correctly tie up harness and wire:
Accelerator knob
(Black)
(Black)
Accelerator motor 2 (ls ac2)
5V power supply
12-position accelerator
potentiometer
Accelerator actuator
Accelerator motor 1 (ls ac1)
(White)
Accelerator motor 2 (hs ac2)
Sensor to ground
6-252
6.4 DTC CLG922E
6.4.76 DTC 221305 Actuator AC1 terminal open-circuited February 3, 2015
Accelerator knob
(Black)
(Black)
Accelerator motor 2 (ls ac2)
5V power supply
12-position accelerator
potentiometer
Accelerator actuator
Accelerator motor 1 (ls ac1)
(White)
Accelerator motor 2 (hs ac2)
Sensor to ground
6-255
CLG922E 6.4 DTC
February 3, 2015 6.4.77 DTC 221306 Actuator AC1 overcurrent
Front
Correctly tie up harness and wire:
2. Turn the multimeter to its resistance function, 3. Check whether the harness is shorted to the
and measure the resistance between the accel- battery. Turn the start switch to the ON position
erator actuator connector terminals 1 and 4 (nor- and switch on the switches of all electrical
mally, >10Ω) equipment, and then measure the voltage
between the harness (No. 907/No. 904) actuator
• Whether a fault developing in the accel-
terminal and the grounding (normally, 0V).
erator actuator?
• Whether the harness is shorted to the
• Yes
battery.
Repair or replace the accelerator actuator.
• Yes
Turn to Step 4
Connect the harness again and wrap the har-
• No
ness.
Turn to Step 2
Turn to Step 4
• No
6-256
6.4 DTC CLG922E
6.4.77 DTC 221306 Actuator AC1 overcurrent February 3, 2015
Turn to Step 3
Accelerator knob
(Black)
(Black)
Accelerator motor 2 (ls ac2)
5V power supply
12-position accelerator
potentiometer
Accelerator actuator
Accelerator motor 1 (ls ac1)
(White)
Accelerator motor 2 (hs ac2)
Sensor to ground
6-258
6.4 DTC CLG922E
6.4.78 DTC 221405 Actuator AC2 terminal open-circuited February 3, 2015
Accelerator knob
(Black)
(Black)
Accelerator motor 2 (ls ac2)
5V power supply
12-position accelerator
potentiometer
Accelerator actuator
Accelerator motor 1 (ls ac1)
(White)
Accelerator motor 2 (hs ac2)
Sensor to ground
6-261
CLG922E 6.4 DTC
February 3, 2015 6.4.79 DTC 221406 Actuator AC2 overcurrent
Front
Correctly tie up harness and wire:
Step 1 Check the accelerator actuator for fault between the controller (J2-07 and J7-04) and
the accelerator actuator for wear respectively.
When replacing the components, please
Disconnect both the controller and the solenoid
be sure to use LiuGong parts. valve:
• Inspection method 2. Check the two harnesses for short-circuit:
Turn the start switch to the OFF position and Turn the multimeter to its resistance function,
disconnect the accelerator actuator connectors: and measure the resistance of the harness (No.
1. Check the connector for moisture, oil dirt and 907/No. 904) between the actuator terminals
other. (normally, >100K).
2. Turn the multimeter to its resistance function, 3. Check whether the harness is shorted to the
and measure the resistance between the accel- battery. Turn the start switch to the ON position
erator actuator connector terminals 1 and 4 (nor- and switch on the switches of all electrical
mally, >10Ω) equipment, and then measure the voltage
between the harness (No. 907 and No. 904)
• Whether a fault developing in the accel-
actuator terminal and the grounding (normally,
erator actuator?
0V).
• Yes
• Whether the harness is shorted to the
Repair or replace the accelerator actuator.
battery.
Turn to Step 4
• Yes
• No
Connect the harness again and wrap the har-
Turn to Step 2
ness.
Turn to Step 4
6-262
6.4 DTC CLG922E
6.4.79 DTC 221406 Actuator AC2 overcurrent February 3, 2015
• No
Turn to Step 3
Tracker (optional)
Electric lock ON
Power -
Power +
Electric lock
Ground
Controller
(Black)
CAN 1/2 shield
CAN 1 low
CAN 1 high
Definition of
connector pin
serial number
Controller
Controller connector
Front
Monitor
Battery power
Battery power
Electric lock
Ground
Ground
supply
supply
ON
Tracker (optional)
Electric lock ON
Power -
Power +
Electric lock
Ground
6-266
6.4 DTC CLG922E
6.4.81 DTC 231014 CAN bus communication error February 3, 2015
Accelerator knob
(Black)
(Black)
Accelerator motor 2 (ls ac2)
5V power supply
12-position accelerator
potentiometer
Accelerator actuator
Accelerator motor 1 (ls ac1)
(White)
Accelerator motor 2 (hs ac2)
Sensor to ground
6-268
6.4 DTC CLG922E
6.4.82 DTC 241014 Accelerator knob outside the measurement range February 3, 2015
Controller
Fuel pump relay
Ignition switch
Battery
6-271
CLG922E 6.4 DTC
February 3, 2015 6.4.83 DTC 251004 Fuel pump relay shorted to the ground
Component location
Fault diagnosis and elimination pro- Step 2 Check the connectors for fault
Figure
Controller
Controller connector
Front
6-274
6.4 DTC CLG922E
6.4.84 DTC 251005 Fuel pump relay open-circuited or shorted to the battery February 3, 2015
Controller
Fuel pump relay
Ignition switch
Battery
6-275
CLG922E 6.4 DTC
February 3, 2015 6.4.84 DTC 251005 Fuel pump relay open-circuited or shorted to the battery
Component location
Step 3 Check the connector for fault Step 4 Check whether this fault is eliminated
Controller connector
Front
6-278
6.4 DTC CLG922E
6.4.85 DTC 261011 GPS Antenna fault February 3, 2015
Display
Step 3 Check whether this fault is eliminated
• Inspection method
Turn the start switch to the ON position and re-
GPS
check the DTC.
• Has this fault been eliminated?
• Yes
Maintenance is over
• No
Fault diagnosis and elimination pro- Troubleshoot the faults according to the steps
again or contact the local LiuGong dealer and
cedures
authorized service center.
Step 1 Check the antenna connector for loose-
ness and fall-off.
• Inspection method
Manually check whether the antenna connector
becomes loose or falls off.
6-279
CLG922E 6.4 DTC
February 3, 2015 6.4.86 DTC 261111 GPS Module fault
6.4.86 DTC 261111 GPS Module 6.4.87 DTC 261211 GSM Signal
fault fault
Description of Description of
DTC Consequence DTC Consequence
Fault Fault
GPS signals GSM signal is
261211 GSM signal fault
261111 GPS module fault cannot be weak.
received.
System description
System description
Use the GPS (Global Positioning System) to
Use the GPS (Global Positioning System) to position the excavator and use the GSM mobile
position the excavator and use the GSM mobile communication network to achieve the two-way
communication network to achieve the two-way data exchange with the central control center to
data exchange with the central control center to realize remote monitoring and control.
realize remote monitoring and control.
Component location
Component location
GPS and GSM antenna
GPS antenna
Display
Display
GPS
GPS
• No
Turn to Step 3
6.4.89 DTC 261411 SIM card Fault diagnosis and elimination pro-
read fault cedures
Step 1 Check whether the SIM card becomes
loose.
Description of
DTC Consequence
Fault • Inspection method
GPS cannot
Turn the start switch to the OFF position, and
261411 SIM card read fault operate
properly. manually check whether the SIM card becomes
loose.
System description
• If the SIM card becomes loose?
The GPS positioning information is transmitted
• Yes
to the monitoring center through the SIM card.
Fix the SIM card.
Turn to Step 2
Component location
• No
Turn to Step 2
GPS and GSM antenna
Display
Step 2 Check whether this fault is eliminated
• Inspection method
Turn the start switch to the ON position and re-
GPS
(SIM card check the DTC.
inside GPS)
Ignition switch
Tracker (optional)
Electric lock
ON
Power -
Power +
Electric lock
Ground
6-283
CLG922E 6.4 DTC
February 3, 2015 6.4.90 DTC 261512 Abnormal GPS heartbeat
Component location Step 2 Check the harness (No. 149) for fault.
• Inspection method
GPS antenna Turn the start switch to the ON position
Display
Dismantle the GPS connector C3. Make sure no
pin of the connector is bent. Turn the multimeter
to its voltage function, and measure the voltage
between the connector port 4 and the ground-
GPS
ing. The voltage should be 24V. Otherwise, a
fault develops in the harness (No. 149).
• Is there a fault in the harness (No. 149)?
• Yes
Rewire
Turn to Step 3
Fault diagnosis and elimination pro-
• No
cedures
Turn to Step 3
Step 1 Check whether the GPS connector
becomes loose and falls off.
Step 3 Check whether this fault is eliminated
• Inspection method
• Inspection method
Manually check the GPS connector for loose-
Turn the start switch to the ON position and re-
ness or fall-off
check the DTC.
• Whether the GPS connector becomes
• Has this fault been eliminated?
loose and falls off?
• Yes
• Yes
Maintenance is over
Tighten the GPS connector
• No
Turn to Step 3
Troubleshoot the faults according to the steps
• No
again or contact the local LiuGong dealer and
Turn to Step 2 authorized service center.
6-284
6.4 DTC CLG922E
6.4.91 DTC 261611 Level-1 automatic locking, abnormal GPS heartbeat, excavator restricted for use February 3, 2015
Description of
DTC Consequence
Fault
Level-1 automatic
locking, abnormal The excavator
261611 GPS heartbeat, is restricted for
excavator use
restricted for use
Ignition switch
Tracker (optional)
Electric lock
ON
Power -
Power +
Electric lock
Ground
6-285
CLG922E 6.4 DTC
February 3, 2015 6.4.91 DTC 261611 Level-1 automatic locking, abnormal GPS heartbeat, excavator restricted for use
Component location Step 2 Check the harness (No. 149) for fault.
• Inspection method
GPS antenna Turn the start switch to the ON position
Display
Dismantle the GPS connector C3. Make sure no
pin of the connector is bent. Turn the multimeter
to its voltage function, and measure the voltage
between the connector port 4 and the ground-
GPS
ing. The voltage should be 24V. Otherwise, a
fault develops in the harness (No. 149).
• Is there a fault in the harness (No. 149)?
• Yes
Rewire.
Turn to Step 3
Fault diagnosis and elimination pro-
• No
cedures
Turn to Step 3
Step 1 Check whether the GPS connector
becomes loose and falls off.
Step 3 Check whether this fault is eliminated
• Inspection method
• Inspection method
Manually check the GPS connector for loose-
Turn the start switch to the ON position and re-
ness or fall-off
check the DTC.
• Whether the GPS connector becomes
• Has this fault been eliminated?
loose and falls off?
• Yes
• Yes
Maintenance is over
Tighten the GPS connector
• No
Turn to Step 3
Troubleshoot the faults according to the steps
• No
again or contact the local LiuGong dealer and
Turn to Step 2 authorized service center.
6-286
6.4 DTC CLG922E
6.4.92 DTC 261614 Level-1 forced locking, overdue payment, excavator restricted for use February 3, 2015
Description of
DTC Consequence
Fault
Level-1 forced
locking, overdue The excavator
261614 payment, is restricted for
excavator use.
restricted for use
System description
Use the GPS (Global Positioning System) to
position the excavator and use the GSM mobile
communication network to achieve the two-way
data exchange with the central control center to
realize remote monitoring and control.
Ignition switch
Tracker (optional)
Electric lock
ON
Power -
Power +
Electric lock
Ground
6-288
6.4 DTC CLG922E
6.4.93 DTC 261711 Level-2 automatic locking, abnormal GPS heartbeat, excavator restricted for use February 3, 2015
Component location Step 2 Check the harness (No. 149) for fault.
• Inspection method
GPS antenna Turn the start switch to the ON position
Display
Dismantle the GPS connector C3. Make sure no
pin of the connector is bent. Turn the multimeter
to its voltage function, and measure the voltage
between the connector port 4 and the ground-
GPS
ing. The voltage should be 24V. Otherwise, a
fault develops in the harness (No. 149).
• Is there a fault in the harness (No. 149)?
• Yes
Rewire.
Turn to Step 3
Fault diagnosis and elimination pro-
• No
cedures
Turn to Step 3
Step 1 Check whether the GPS connector
becomes loose and falls off.
Step 3 Check whether this fault is eliminated
• Inspection method
• Inspection method
Manually check the GPS connector for loose-
Turn the start switch to the ON position and re-
ness or fall-off
check the DTC.
• Whether the GPS connector becomes
• Has this fault been eliminated?
loose and falls off?
• Yes
• Yes
Maintenance is over
Tighten the GPS connector
• No
Turn to Step 3
Troubleshoot the faults according to the steps
• No
again or contact the local LiuGong dealer and
Turn to Step 2 authorized service center.
6-289
CLG922E 6.4 DTC
February 3, 2015 6.4.94 DTC 261714 Level-2 forced locking, overdue payment, excavator restricted for use
System description
Fault diagnosis and elimination pro-
Use the GPS (Global Positioning System) to
position the excavator and use the GSM mobile cedures
communication network to achieve the two-way Step – Pay the loan on time.
data exchange with the central control center to
realize remote monitoring and control.
Fan reversing
Avoid friction with sharp metal edges.
solenoid valve
Try to keep far way from oil and water.
Fault diagnosis and elimination pro- Try to keep far away from high temperature
parts (e.g. engine body).
cedures
• Inspection method
Step 1 Check the fan reversing solenoid valve
for fault 1. Check the harness (No. 904) between the
controller (J2-04) and the fan reversing solenoid
When replacing the components, please valve for wear.
be sure to use LiuGong parts. 2. Disconnect the connectors from the fan
• Inspection method reversing solenoid valve and the controller. Turn
Turn the start switch to the OFF position, and the multimeter to its resistance function, and
disconnect the fan reversing solenoid valve con- measure the resistance between the harness
nector. (No. 904) solenoid valve terminal and the
1. Check the connector for moisture, oil dirt and grounding (normally, >100K).
other. • Whether the harness is shorted to the
2. Turn the multimeter to its resistance function, ground or not?
and measure the resistance between the fan • Yes
reversing solenoid valve terminals 1 and 2 (nor- Connect the harness again and wrap the har-
mally, 16-40Ω). ness.
• Whether a fault developing in the fan Turn to Step 4
reversing solenoid valve or not? • No
• Yes Turn to Step 3
Repair or replace the fan reversing solenoid
valve.
Turn to Step 4
• No
6-292
6.4 DTC CLG922E
6.4.96 DTC 271304 Fan reversing solenoid valve shorted to the ground February 3, 2015
Fan reversing
Avoid friction with sharp metal edges.
solenoid valve
Try to keep far way from oil and water.
Fault diagnosis and elimination pro- Try to keep far away from high temperature
parts (e.g. engine body).
cedures
• Inspection method
Step 1 Check the fan reversing solenoid valve
for fault 1. Check the harness (No. 904) or grounding
wire (No. 229) between the controller and the
When replacing the components, please fan reversing solenoid valve for wear.
be sure to use LiuGong parts. Disconnect the connectors from the fan revers-
• Inspection method ing solenoid valve and the controller.
Turn the start switch to the OFF position and 2. Check whether the harness is shorted to the
disconnect the fan reversing solenoid valve con- battery. Turn the start switch to the ON position
nector: and turn on all switches of the electrical equip-
1. Check the connector for looseness, rust, ment, and then measure the voltage between
bending and damage. the harness (No. 904) solenoid valve terminal
2. Turn the multimeter to its resistance function, and the grounding (normally, 0V).
and measure the resistance between the fan 3. Check the harness for open-circuit. Turn the
reversing solenoid valve terminals 1 and 2 (nor- multimeter to its resistance function, and mea-
mally, 16-40Ω). sure the resistance of the harness (No. 904)
between the controller and the solenoid valve
• Whether a fault developing in the fan
and that of the harness (No. 229) between the
reversing solenoid valve or not?
solenoid valve and the grounding (normally,
• Yes
<10Ω).
Repair or replace the fan reversing solenoid
• Whether the harness open-circuited or
valve.
shorted to the battery or not?
Turn to Step 4
• Yes
• No
6-295
CLG922E 6.4 DTC
February 3, 2015 6.4.97 DTC 271305 Fan reversing solenoid valve open-circuited or shorted to the battery
Connect the harness again and wrap the har- Step 4 Check whether this fault is eliminated
ness. • Inspection method
Turn to Step 4 Turn the start switch to the ON position and re-
• No check for fault.
Turn to Step 3 • Has this fault been eliminated?
• Yes
Step 3 Check the connector for fault. Maintenance is over
When replacing the components, please • No
be sure to use LiuGong parts. Troubleshoot the faults according to the steps
• Inspection method again or contact the local LiuGong dealer and
authorized service center.
Connect the fan reversing solenoid valve con-
nector and disconnect the controller connector.
Turn the multimeter to its resistance function,
and measure the resistance between the con-
troller port J2-04 and the grounding (normally,
16-40Ω).
When the resistance is abnormal, this indi-
cates the connector is poorly contacted.
• Whether a fault developing in the con-
nector or not?
• Yes
Replace the connector.
Turn to Step 4
• No
Turn to Step 4
6-296
6.4 DTC CLG922E
6.4.98 DTC 271404 Fan drive solenoid valve shorted to the ground February 3, 2015
Controller
Front
Correctly tie up harness and wire:
Fan drive
Try to keep far way from oil and water.
solenoid valve
Try to keep far away from high temperature
parts (e.g. engine body).
Controller
Front
Correctly tie up harness and wire:
Fan drive
Try to keep far way from oil and water.
solenoid valve
Try to keep far away from high temperature
parts (e.g. engine body).
Turn to Step 3
Controller
Controller
Turn to Step 3
System description
The battery functions: Store the electric energy;
when the engine starts and powers the motor;
Fault diagnosis and elimination pro-
for gasoline engine, it can power the ignition cedures
system; stabilize the system voltage; when the Step 1 The battery needs to be charged.
motor does not generate electricity or the volt-
age is low, the battery powers the electric equip-
Check the battery hydrometer color
when the start switch is in "OFF" posi-
ment; when the motor is overloaded because of
tion.
too many electric equipment, the battery assists
the motor to power; the battery is equivalent to a • Inspection method
big capacitor, it will protect the components and 1. Check the color of the battery hydrometer
parts in case of transient overvoltage. through the opening on the cover of the battery,
black means that the battery needs to be
charged.
2. Measure the battery voltage with the multime-
Hydrometer
ter. Turn the multimeter to its DC voltage func-
tion (200V), and connect the red probe to the
OK positive battery terminal and the black probe to
the negative battery terminal. Under the normal
Change
condition, the voltage is 24V. If the voltage is too
Replace
low, the battery needs to be charged.
• Whether the battery needs to be
charged or not?
• Yes
Charging of battery
Turn to Step 3
• No
Turn to Step 2
6-309
CLG922E 6.5 Fault diagnosis of electrical system
February 3, 2015 6.5.1 E1-Troubleshooting for battery undervoltage
System description
The battery functions: Store the electric energy;
when the engine starts and powers the motor;
for gasoline engine, it can power the ignition
system; stabilize the system voltage; when the
motor does not generate electricity or the volt-
age is low, the battery powers the electric equip-
Fault diagnosis and elimination pro-
ment; when the motor is overloaded because of
too many electric equipment, the battery assists
cedures
the motor to power; as the battery is equivalent Step 1 Normal battery level
to a big capacitor, it will protect the components Check the battery hydrometer color
and parts in case of transient overvoltage.
when the start switch is in "OFF" posi-
Common maintenance: The electric quantity
tion.
of the battery can be learned by the change
• Inspection method
of the hydrometer color. Green – normal,
black – requiring to be charged, white – the Check the color of battery hydrometer through
battery is scrap. the opening on the cover of the battery.
• Is the color of battery hydrometer
green?
• Yes
Hydrometer The battery level is normal.
Turn to Step 4
OK
• No
Change Turn to Step 2
Replace
6-311
CLG922E 6.5 Fault diagnosis of electrical system
February 3, 2015 6.5.2 E2-Troubleshooting for abnormal battery
Step 2 The battery needs to be charged. Step 4 Check whether this fault is eliminated
when the start switch is in "OFF" posi- Check the color of battery hydrometer through
tion. the opening on the cover of the battery.
• Has this fault been eliminated?
• Inspection method
Check the color of battery hydrometer through • Yes
the opening on the cover of the battery. Maintenance is over
• Is the color of battery hydrometer • No
black? Troubleshoot the faults according to the steps
• Yes again or contact the local LiuGong dealers and
authorized service centers.
Charging of battery
Turn to Step 4
• No
Turn to Step 3
Engine controller
(Black)
Monitor
CAN 1/2 shield
CAN 1 low
CAN 1 high
Handle pilot
pressure switch
Engine speed dial
5V power supply
12-position throttle
potentiometer
(White)
Pedal pressure switch
Sensor to ground
Pressure switch
Pressure switch
6-313
CLG922E 6.5 Fault diagnosis of electrical system
February 3, 2015 6.5.3 E3-Automatic slowdown failed
Pressure switch
• Yes
of appurtenances
Operate the control key of automatic idle speed
to enable the automatic idle speed function.
Turn to Step 4
• No
Turn to Step 2
ECU controller
Turn to Step 3
6-314
6.5 Fault diagnosis of electrical system CLG922E
6.5.3 E3-Automatic slowdown failed February 3, 2015
Start relay K1
Battery
To ignition switch B2
Battery moter
Battery relay
Engine earthing
6-316
6.5 Fault diagnosis of electrical system CLG922E
6.5.4 E4-Engine start fault February 3, 2015
Ignition witch
Pilot solenoid valve switch
IPC Controller
Engine start
To battery relay B
Engine controller
Start protection
Satety relay K11 Pilot control start relay K7 Controller control start relay K8 ECM control start relay K9
6-318
6.5 Fault diagnosis of electrical system CLG922E
6.5.4 E4-Engine start fault February 3, 2015
Pilot cut-off
Fuse box • Yes
valve switch
Overhaul the machine in accordance with the
corresponding fault diagnosis and exclusion
step of the DTC.
Turn to Step 15
• No
Starting motor Turn to Step 2
When replacing the components, please The start switch is in OFF state.
be sure to use LiuGong parts.
When replacing the components, please
• Inspection method
be sure to use LiuGong parts.
1.Turn “ON” the start switch, and then check the
• Inspection method
display for the alarm with the DTC of
1. Open the electronic control unit, remove the
101001.101017.
fuse, visibly check whether the fuse blows or
2. Measure the battery voltage with the multime-
check whether both ends of the fuse are con-
ter. Turn the multimeter to its DC voltage func-
nected by the multimeter on the diode gear.
tion (200V), and connect the red probe to the
2. Open the fuse box, unplug the fuses 1 and 14
positive battery terminal and the black probe to
by a fuse clip, and observe by visual inspection
the negative battery terminal. See the schematic
whether the fuse is blown or turn the multimeter
diagram for detection as follows:
to its diode function to measure whether both
ends of fuse are connected.
Notice: There may be ground fault, so please
refer to step 14.
• Is fuse blown?
• Yes
Replace fuse
Turn to Step 15
• No
Black probe Turn to Step 5
Red probe
Step 10 ECM controller start relay K9 fails. Step 11 start relay K1 fails.
When replacing the components, please When replacing the components, please
be sure to use LiuGong parts. be sure to use LiuGong parts.
• Inspection method • Inspection method
Measure the resistance among all contacts of Measure the resistance among all contacts of
ECM controller start relay K9 with a multimeter. start relay K1 with a multimeter.
1. Remove ECM controller start relay K9, and 1. Remove the start relay K1, and then measure
then measure the resistance among all con- the resistance among all contacts.
tacts. • The resistance of coil is about 79-81Ω.
• The resistance between 85 and 86 (coil • The resistance of the main contact is
resistance) is about 353-358Ω. infinite.
• The resistance between 30 and 87 is 2. Supply 24V power to both ends of the coil and
infinite. measure the resistance between two main con-
• The resistance between 30 and 87a is less tacts.
than 10Ω. The resistance between two main contacts is
2. Switch on 24V power to both ends of 85 and less than 10Ω.
86, and measure the resistance between each • Whether start relay K1 fails or not?
two contacts. • Yes
• The resistance between 30 and 87 is less Replace the starter relay.
than 10Ω. Turn to Step 15
• The resistance between 30 and 87a is • No
infinite.
Turn to Step 12
• Whether ECM controller start relay K9
fails or not?
• Yes
Replace the ECM controller start relay.
Turn to Step 15
• No
Turn to Step 11
6-323
CLG922E 6.5 Fault diagnosis of electrical system
February 3, 2015 6.5.4 E4-Engine start fault
Step 12 Internal fault of starter motor switch to OFF position, measure the resistance
of the following circuit, and the resistance shall
Remove the wiring on the input end 50
be all less than 10Ω in normal condition.
and end 30 on the start motor.
1. Wire 137 on the main contact of battery relay
When replacing the starter motor, - wire 136 of the main contact of start relay K1.
please be sure to use the LiuGong parts. 2. Wire 182 on the main contact of start relay K1
- end 30 of starter motor.
• Inspection method
3. Wire 004 on the main contact of battery relay
1. Turn the start switch to ON position, and then
- X2(8) - X1(5) - end B1 of start switch.
measure the voltage to earth of wire 108 on the
end 50, and make sure it is 24V. 4. End S of start switch - X2(2) - end 30 of start
relay K7 controlled by pilot.
2. Turn the start switch to START position, and
then measure the voltage to earth of wire 182 on 5. End 87 of start relay K7 controlled by pilot -
the end 30, and make sure it is 24V. start relay K8 (30-87A) controlled by controller -
ECN control start relay K9k8 (30-87A) - X1(19) -
If the input signals are normal, but the starter
wire 181 on the start relay K1.
motor does not rotate, it can be judged that
there is an internal fault in the starter motor. 6. Wire 260 on the start relay K1 - frame ground
(GND)
• Whether the start motor has internal
7. Wire 102 on the main contact of battery relay
fault or not?
- end 30 of the safety relay K11.
• Yes
8. End 87 of safety relay K11 - X1(21) - switch of
Replace the start motor. pilot shut -off valve (3-1) - X2(3) - end 86 of start
Turn to Step 15 relay K7 controlled by pilot.
• No 9. Wire 85 on the start relay K7 controlled by
Turn to Step 13 pilot - frame ground (GND).
10. End B2 of start switch - X1(28) - end 86 of
Step 13 Open circuit of wire in harness or poor safety relay K11.
connector contact. 11. Wire 85 on the safety relay K11 - frame
ground (GND).
Correctly tie up harness and wire.
12. J2(female 23) - X2(15) - end 86 of the start
Avoid folding or bending the harness forci- relay K8 controlled by controller.
bly. 13. End 85 on the start relay K8 controlled by
It shall be kept away from moving compo- controller - frame ground (GND).
nents as far as possible to prevent tensile 14. J2 (female 9) - X2(11) - end 86 of the start
fault and wear. relay K7 controlled by ECM.
Avoid friction with sharp metal edges. 15. End 86 of the start relay K7 controlled by
Try to keep far way from oil and water. ECM - X2(9) - J22 (female 57).
• Inspection method 16. End S of start switch - J1 (female 10).
Remove the battery cable (-), and turn the start 17. End B2 of start switch - End of battery relay.
6-324
6.5 Fault diagnosis of electrical system CLG922E
6.5.4 E4-Engine start fault February 3, 2015
18. End E of battery relay - frame ground (GND). Connect the harness again and wrap the har-
• Is the harness open? ness
Ignition switch
Engine controller
Ignition
Switch ON
Engine controller 5A
Power -
Engine controller 30A Power -
Power -
Electric lock power 20A Power +
Power +
Power +
6-326
6.5 Fault diagnosis of electrical system CLG922E
6.5.5 E5-Engine shutdown during operation February 3, 2015
Fuse box
Step 2 Blowing of fuse.
• Inspection method • No
Step 3 Open circuit of wire in harness or poor Step 4 Conductor in harness -- short circuit with
connector contact. ground wire
Ignition switch
Engine controller
Ignition
Switch ON
Engine controller 5A
Power -
Engine controller 30A Power -
Power -
Electric lock power 20A Power +
Power +
Power +
6-329
CLG922E 6.5 Fault diagnosis of electrical system
February 3, 2015 6.5.6 E6-Engine non-shutdown
Preheating relay K3
Grid heater
Engine controller
Air intake
preheating (+)
Preheating
ground wire
Ignition switch
Connect the harness again and wrap the har- • Has this fault been eliminated?
ness • Yes
Turn to Step 7 Maintenance is over
• No • No
Turn to Step 6 Find out the engine system fault or contact the
local LiuGong dealers or authorized service cen-
ters.
6-335
CLG922E 6.5 Fault diagnosis of electrical system
February 3, 2015 6.5.8 E8-All the work implements, revolving and travel unable to move
Battery relay
6-336
6.5 Fault diagnosis of electrical system CLG922E
6.5.8 E8-All the work implements, revolving and travel unable to move February 3, 2015
• Inspection method
Remove the battery cable (-), and turn the start
switch to OFF position, check whether the fol-
lowing circuit forms a short circuit with the
ground, and normally the resistance between
any check point and the ground shall be greater
than 1MΩ.
1. Wire 102 on the main contact of battery relay
- end 30 of the safety relay K11.
2. End 87 of safety relay K11 - X1(21) - pilot
shut-off valve switch (3-2) - pilot shut-off sole-
noid valve A1 (female 1).
3. End B2 of start switch - X1(28) - end 86 of
safety relay K11.
• Is the harness short?
• Yes
Connect the harness again and wrap the har-
ness
Turn to Step 6
• No
Turn to Step 6
Display
Ignition switch
Electric lock ON
Battery power
Battery power
Ground
Ground
supply
supply
(Black) (Gray)
Controller,
display 30A
Battery relay
6-340
6.5 Fault diagnosis of electrical system CLG922E
6.5.9 E9-Display panel showing nothing February 3, 2015
Fuse box
Try to keep far way from oil and water.
• Inspection method
Remove the battery cable (-), and turn the start
Fault diagnosis and elimination pro- switch to OFF position, measure the resistance
of the following circuit, and the resistance shall
cedures
be all less than 10Ω in normal condition.
Step 1- Blowing of fuse 15
1. Wire 004 on the main contact of battery relay
When replacing the components, please -X2(8)-X1(1)-X3(6)- C4(female 6) of the display.
be sure to use LiuGong parts. 2. X1(female 1)-X4(7)-C4 (female 7) of the dis-
play.
• Inspection method
3. C4 (female 5)-X4(5) of the display - frame
Unplug the fuse 15 by a fuse clip, observe by
ground (GND).
visual inspection whether fuse is blown or turn
4. C4 (female 10)-X3(10) of the display - frame
the multimeter to its diode function to measure
ground (GND).
whether both ends of fuse are connected.
5. End S of start switch -X3(8)- C4(female 26) of
Notice: There may be ground fault, so please
the display.
refer to step 3.
• Is the harness open?
• Is fuse 15 is blown?
• Yes
• Yes
Connect the harness again and wrap the har-
Replace fuse.
ness
Turn to Step 5
Turn to Step 5
• No
• No
Turn to Step 2
Turn to Step 3
6-341
CLG922E 6.5 Fault diagnosis of electrical system
February 3, 2015 6.5.9 E9-Display panel showing nothing
Engine controller
Oil temperature
Oil
temperature
ground
Front
Correctly tie up harness and wire:
Turn the knob start switch to OFF position • Is the harness open?
and disconnect sensor connector. • Yes
1. Check the connector for looseness, rust, Connect the harness again and wrap the har-
bending and damage. ness
2. Turn the multimeter to its resistance function Turn to Step 4
(20KΩ), and measure the resistance between • No
the sensor connector terminals 1 and 2, compar-
Turn to Step 3
ing the result with the parameter table (normally,
<4K).
• Whether the hydraulic oil temp sensor
fails or not?
• Yes
Replace the hydraulic oil temp sensor.
Turn to Step 4
• No
Turn to Step 2
6-344
6.5 Fault diagnosis of electrical system CLG922E
6.5.10-Incorrectly displayed hydraulic oil temperature February 3, 2015
Step 3 Ground fault of wire in harness ----short Step 4 Check whether this fault is eliminated
to ground wire • Inspection method
Shutdown operation is needed. Operate the machine, and check whether each
action is normal.
• Inspection method
• Has this fault been eliminated?
Remove the battery cable (-), and turn the start
switch to OFF position, check whether the fol- • Yes
lowing circuit forms a short circuit with the Maintenance is over
ground, and normally the resistance between • No
any check point and the ground shall be greater Contact local LiuGong dealers and authorized
than 1MΩ. service centers.
J22 (female 48) of engine controller - P7
(female 1) of hydraulic oil temp sensor.
• Is the harness open?
• Yes
Connect the harness again and wrap the har-
ness
Turn to Step 4
• No
Turn to Step 4
6-345
CLG922E 6.5 Fault diagnosis of electrical system
February 3, 2015 6.5.11 E11-Fuel gauge unable to display correct value
IPC Controller
Fuel level
Fuel level sensor parameter table 2. Turn the multimeter to its resistance function,
and measure the resistance between the fuel
(For the details, see the figure.)
level sensor connector terminals 1 and 2 (nor-
Component location mally, < 2K, for the specific resistance, see the
figure.).
Front
Step 2 Check the harness for open-circuit (b) Turn the multimeter to its resistance func-
tion, and measure the resistance between
Correctly tie up harness and wire:
the connector ports J2-30 and sensor har-
Avoid folding or bending the harness forci- ness (normally, <10Ω).
bly.
It shall be kept away from moving compo-
nents as far as possible to prevent tensile
fault and wear.
Avoid friction with sharp metal edges.
Try to keep far way from oil and water.
Try to keep far away from high temperature
parts (e.g. engine body) as far as possible. White wire
• Inspection method
1. Check the harness (No. 930) and the ground- To the black probe
ing wire (No.227) between the controller (J2-30) To the red probe
Gray wire
6-348
6.5 Fault diagnosis of electrical system CLG922E
6.5.11 E11-Fuel gauge unable to display correct value February 3, 2015
Step 3 Check the connector for fault. Step 4 Check whether this fault is eliminated
be sure to use LiuGong parts. Turn the start switch to the ON position and re-
check the DTC.
• Inspection method
• Has this fault been eliminated?
Connect the water-in-fuel sensor connector and
disconnect the controller connector. Turn the • Yes
multimeter to its resistance function, and mea- Maintenance is over
sure the resistance between the harness at the • No
controller port J2-30 and the grounding (nor- Troubleshoot the faults according to the steps
mally, <2K, for the details, see the figure). again or contact the local LiuGong dealers and
authorized service centers.
Connect the black
probe to ground
Oil level
6-350
6.5 Fault diagnosis of electrical system CLG922E
6.5.12 E12-Windshield wiper uable to work February 3, 2015
Wiper switch
(Gray) (Black)
Wiper relay K6
Battery relay
6-351
CLG922E 6.5 Fault diagnosis of electrical system
February 3, 2015 6.5.12 E12-Windshield wiper uable to work
Step 3 Open circuit of wire in harness or poor Step 4 Wire fault in harness - short circuit with
connector contact ground wire
Vent
Vent servo
motor
Foot vent
Water tempera-
ture sensor
b. Bottom view
Internal air
sensor
Expansion valve
inlet
Internal-to-external
air switching motor
Expansion valve
outlet
6-356
6.5 Fault diagnosis of electrical system CLG922E
6.5.13 E13-A/C panel unable to display February 3, 2015
c. Rear view
Frost-prevention
probe
Switch
Fan motor
6-357
CLG922E 6.5 Fault diagnosis of electrical system
February 3, 2015 6.5.13 E13-A/C panel unable to display
ness – harness 128 in the cab is 24V with a Check A/C 30A fuse, and observe by visual
multimeter. inspection whether the fuse is blown or turn the
multimeter to its diode function to measure
• Whether there is 24V voltage at No. 128
whether both ends of fuse are connected.
wire?
• Is A/C 30A fuse blown?
• Yes
• Yes
Find out the reason according to Step 2.
Replace A/C 30A fuse.
Turn to Step 2
Turn to Step 6
• No
• No
Check whether A/C 30A fuse is damaged.
Find out the reason according to Step 4.
Turn to Step 3
Turn to Step 4
When replacing the components, please When replacing A/C fuse, please make
Check whether the ground connection of the Check 5A fuse of the evaporator as wire har-
mutually plugged A/C harness and base ness in the cab. Visually observe whether the
fuse is fused or use a multimeter and a diode to
machine harness – harness 210 in the cab is in
check whether both ends of the fuse are con-
good condition with a multimeter.
nected.
• Is there an open circuit in the ground
• Is A/C panel fuse damaged?
wire?
• Yes
• Yes
Replace 5A fuse of the A/C panel
Check the ground circuit of base machine har-
Turn to Step 6
ness.
Turn to Step 6 • No
Turn to Step 5
6-358
6.5 Fault diagnosis of electrical system CLG922E
6.5.13 E13-A/C panel unable to display February 3, 2015
Fault diagnosis and elimination pro- • Whether outlet airflow is changed with
adjustment of the blowing rate switch?
cedures
• Yes
Step 1 Blower main relay fault.
Turn to Step 3
When replacing the A/C relay, please
• No
make sure to use LiuGong parts. Replace the power transistor
• Inspection method Turn to Step 6
Use the multimeter to measure the resistance
value between all contacts of the fan main relay Step 3 Blower motor fault.
according to the table below and judge whether
relay is damaged the resistance value provided.
When replacing the components, please
be sure to use LiuGong parts.
Code for both • Inspection method
Standard
Relay ends of wire
value Unplug the blower of the evaporator as, and
(contact)
Unplug the relay Measure coil check whether there is short circuit or open cir-
240±10Ω
and measure the resistance cuit of blower coil winding with a multimeter.
resistance
between the • Whether the blower fails?
contacts of the E-3 Contact Infinite
• Yes
relay
Replace the blower
• Whether the blower main relay fails?
Turn to Step 6
• Yes
• No
Replace the blower main relay.
Find out the reason according to Step 4
Turn to Step 6
Turn to Step 4
• No
Turn to Step 2
6-360
6.5 Fault diagnosis of electrical system CLG922E
6.5.14 E14-No wind or abnormal air volume of air conditioner February 3, 2015
Step 4 A/C circuit fault. Step 6 Check whether this fault is eliminated
sure to use LiuGong parts. Operate the machine, and check whether each
action is normal.
• Inspection method
• Has this fault been eliminated?
Check whether connectors of A/C harness are
connected stably, and whether there is open cir- • Yes
cuit or short circuit caused by damage of wires. Maintenance is over
• Whether A/C wiring is abnormal? • No
When replacing the components, please Find out the reason according to Step 3
Turn to Step 3
be sure to use LiuGong parts.
• Inspection method
Step 3 High-low voltage protection switch fault.
Check whether the electromagnetic coil circuit of
the compressor clutch relay is open with a multi- When replacing the components, please
meter. be sure to use LiuGong parts.
• Whether the compressor clutch relay • Inspection method
fails? Unplug the pressure protection switch wiring
• Yes harness on the high-pressure side connector of
Replace the compressor clutch relay the expansion valve, and use a multimeter to
Turn to Step 8 check whether both ends of the pressure switch
is connected. When the system pressure is
• No
larger than 0.196 MPa and less than 3.14 MPa,
Check in accordance with Step 2.
the pressure switch shall be connected.
Turn to Step 2
• Whether the high and low voltage pro-
tection switch is damaged?
• Yes
Replace the high and low voltage protection
switch.
Turn to Step 8
• No
Find out the reason according to Step 4
Turn to Step 4
6-362
6.5 Fault diagnosis of electrical system CLG922E
6.5.15 E15-Poor A/C refrigeration February 3, 2015
When replacing the components, please When replacing the components, please
be sure to use LiuGong parts. be sure to use LiuGong parts.
• Inspection method • Inspection method
Unplug the compressor clutch, and use a multi- Check whether connectors of A/C harness are
meter to check whether the compressor clutch connected stably, and whether there is open cir-
coil is open. Whether the compressor earthing cuit or short circuit caused by damage of wires.
cable is in good condition? • Is there a fault in the A/C wiring?
• Whether the compressor earthing cable • Yes
fails?
Check circuit faults and repair them.
• Yes Turn to Step 8
Replace the A/C compressor. • No
Turn to Step 8 Find out the reason according to Step 7
• No Turn to Step 7
Find out the reason according to Step 5
Turn to Step 5 Step 7 A/C panel fault.
6.5.16 E16-Abnormal alarm of Check whether the internal sensor to the A/C
panel is open-circuited with a multimeter.
the A/C E11 – Internal sensor • Whether the internal sensor is open cir-
wire broken cuit?
• Yes
Fault SN Faults Consequence Check fault points and repair them
Abnormal A/C The service Turn to Step 4
alarm E11 - effect of air
E16 • No
Internal sensor conditioner is
wire broken poor Turn to Step 3
Fault diagnosis and elimination pro-
cedures Step 3 A/C panel fault.
6.5.17 E17-Abnormal alarm of Check whether the internal sensor to the A/C
panel is short-circuited with a multimeter.
the A/C E12- Internal sensor
• Whether the internal sensor is short-cir-
short-circuited cuited?
• Yes
Fault SN Faults Consequence Check fault points and repair them
Abnormal A/C The service Turn to Step 4
alarm E12 - effect of air
E17
Internal sensor conditioner is • No
short-circuited poor
Turn to Step 3
Fault diagnosis and elimination pro-
cedures Step 3 A/C panel fault.
• Inspection method
Step 3 A/C panel fault.
1. Press OFF on the A/C panel, the LCD does
not display, and the A/C stops running; When replacing the components, please
2. Press the increase and decrease keys of the be sure to use LiuGong parts.
temperature setting switch in the meantime for • Inspection method
over 3 seconds, the LCD will display DTCs;
If open circuit is not found through checking by
3. If E15 DTC occurs, check whether the water
step 1.2, it may be internal fault of the A/C
temperature sensor circuit located in the inflow
panel.
side of the warm wind radiator is open with a
• Is it internal fault of the A/C panel?
multimeter.
• Yes
• Whether the water temperature sensor
Replace the A/C panel.
is open-circuited?
Turn to Step 4
• Yes
• No
Replace the water temperature sensor.
Turn to Step 4
Turn to Step 4
• No
Turn to Step 2
6-367
CLG922E 6.5 Fault diagnosis of electrical system
February 3, 2015 6.5.18 E18-Abnormal alarm of the A/C E15 – Water temperature sensor wire broken
3. If E16 DTC occurs, check whether the water If short circuit is not found through checking by
temp sensor circuit located in the inflow side of Step 1 and 2, it may be internal fault of the A/C
panel.
the warm wind radiator is short with a multime-
ter. • Is it internal fault of the A/C panel?
the A/C E180 - Insolation sen- When replacing the components, please
be sure to use LiuGong parts.
sor short-circuited
• Inspection method
Check whether the insolation sensor to the A/C
Fault SN Faults Consequence
Abnormal A/C The service panel is short-circuited with a multimeter.
alarm E18 - effect of air • Whether the insolation sensor is short-
E20
Insolation sensor conditioner is
circuited?
short-circuited poor
• Yes
Fault diagnosis and elimination pro-
Check fault points and repair them
cedures Turn to Step 4
Step 1 Insolation sensor fault
• No
Be sure to use LiuGong parts in replac- Turn to Step 3
ing the insolation sensor.
• Inspection method Step 3 A/C panel fault.
1. Press OFF on the A/C panel, the LCD does When replacing the components, please
not display, and the A/C stops running; be sure to use LiuGong parts.
2. Press the increase and decrease keys of the
• Inspection method
temperature setting switch in the meantime for
If short circuit is not found through checking by
over 3 seconds, the LCD will display DTCs;
Step 1 and 2, it may be internal fault of the A/C
3. If E18 DTC occurs, check whether the circuit
panel.
of the insolation sensor is short with a multime-
ter. • Is it internal fault of the A/C panel?
• No
Turn to Step 2
6-371
CLG922E 6.5 Fault diagnosis of electrical system
February 3, 2015 6.5.20 E20-Abnormal alarm of the A/C E180 - Insolation sensor short-circuited
6.5.21 E21-Abnormal alarm of Step 2 Circuit fault of the air-out servo motor
the A/C E43 – Abnormal outlet When replacing the components, please
be sure to use LiuGong parts.
ventilation doors
• Inspection method
Check whether the circuit from the air-out servo
Fault SN Faults Consequence
motor harness to the A/C panel is short or
Abnormal A/C The service
alarm E43 - effect of air open with a multimeter.
E21
Abnormal outlet conditioner is • Whether the air-out servo motor circuit
ventilation doors poor
fails?
Fault diagnosis and elimination pro- • Yes
cedures Check fault points and repair them
Step 1 Air-out servo motor fault Turn to Step 4
• Inspection method
Step 3 A/C panel fault.
1. Press OFF on the A/C panel, the LCD does
not display, and the A/C stops running; When replacing the components, please
2. Press the increase and decrease keys of the be sure to use LiuGong parts.
temperature setting switch in the meantime for
• Inspection method
over 3 seconds, the LCD will display DTCs;
If short circuit is not found through checking by
3. If E43 DTC occurs, check whether the air-out
Step 1 and 2, it may be internal fault of the A/C
servo motor on the evaporator as is short-cir-
panel.
cuited or open-circuited with a multimeter.
• Is it internal fault of the A/C panel?
• Whether the air-out servo motor fails?
• Yes
• Yes
Replace the A/C panel
Replace the air-out servo motor.
Turn to Step 3
Turn to Step 4
• No
• No
Turn to Step 3
Turn to Step 2
6-373
CLG922E 6.5 Fault diagnosis of electrical system
February 3, 2015 6.5.21 E21-Abnormal alarm of the A/C E43 – Abnormal outlet ventilation doors
6.5.22 E22-Abnormal alarm of Step 2 Circuit fault of the servo motor of the air
mixing door (A/M).
the A/C E44 – Abnormal the air
When replacing the components, please
mixing door be sure to use LiuGong parts.
• Inspection method
Fault SN Faults Consequence
Check whether the circuit from the servo motor
Abnormal A/C The service
alarm E44 - effect of air harness of the air mixing door to the A/C panel
E22
Abnormal air conditioner is is short or open with a multimeter.
mixing doors poor
• Whether the servo motor circuit of the
Fault diagnosis and elimination pro- air mixing door (A/M) fails?
cedures • Yes
Step 1 Air mixing door (A/M) servo motor fault. Check fault points and repair them
(White)
Pressure switch
6-377
CLG922E 6.5 Fault diagnosis of electrical system
February 3, 2015 6.5.23 E23-Travel alarm unable to sound
Arm 1 Arm
Arm 2 cylinder
Bucket
cylinder Bucket Spare
Boom Boom
Boom 1 Boom 2 cylinder
cylinder
Travel Swing
motor-lh Travel-lh Swing motor
Straight Travel
Travel-rh motor-rh
travel
Yes
Yes
Yes
Check the slewing pilot Clean and replace the pilot line
valve for clogging Yes
No
Yes
Yes
Yes
No
Yes
No
The hydraulic pump Hydraulic pump fault:
sounds abnormally. Yes Remove and repair it.
Check whether the abnormal Yes
sound comes from the
hydraulic pump or pump
installation position. Yes
Check whether the pilot Check whether any oil flows Pilot relief valve fault:
pressure is normal. No out from the pilot pump. Yes
Repair or replace it
No
Hydraulic oil
emulsification
Yes
Sample the oil and drop the Let the hydraulic oil sit
This may be due
sample droplets onto the hot for a period of time, and
Yes to water in the
iron plate, and then check remove the water or
hydraulic oil.
for bubbles. replace the oil.
Yes
Yes
No
Yes
No
Yes
No
No
Yes
Yes
No reponse for
slewing single
direction opeation
Yes
Yes Yes
Clogging or Clean or repair the
leakage occurs. pilot line.
Yes
Check whether the swing valve The swing valve element gets stuck:
element gets stuck. Yes Remove or replace it.
No
Yes
Fail to actuate
unilateral travel
mechanism
Yes
No
Yes
No
Troubleshoot
according to H3.
6-389
CLG922E 6.6 Fault diagnosis of the hydraulic system and mechanical system
February 3, 2015 6.6.11 H10-Travel deviation
Travel deviation
Yes
Check whether the travel pilot Travel pilot line and pilot valve fault:
pressure is normal. No Clean, repair and replace it.
Yes
Yes
Yes
Yes
No
Yes No
Yes
Check whether the
Check whether the
confluent valve element
above-mentioned valve Yes
spring is functioning
element gets stuck.
properly.
No
Yes
Confluent valve element
gets stuck: Remove and No Replace spring
repair it.
Check whether the boom, Check the pilot line Pilot valve fault:
arm or bucket pilot pressure No inside for clogging or No Remove and repair it.
is normal. leakage.
No
Check whether the main
relief valve and the port relief Relief valve fault: Remove,
valve are functioning No repair or replace it.
properly.
Yes
Yes
Yes
Troubleshoot according to
Yes
the H11 fault.
6-392
6.6 Fault diagnosis of the hydraulic system and mechanical system CLG922E
6.6.14 H13-Significantly reduced engine speed or engine stalling February 3, 2015
Yes
Yes