PX-LR1130/AG10 Battery Spec
PX-LR1130/AG10 Battery Spec
094
PX-LR1130/AG10
Battery Spec
Model: PX-LR1130/AG10
Dora
Product Specification 产品规格书 LR1130 0.%Hg
1. Scope
This specification is applicable to Power Xtra’s alkaline zinc-manganese dioxide button cell: LR1130/AG10
2 . Designations
3.Chemical System
Zinc-Manganese Dioxide (Potassium Hydroxide Electrolyte)
4.Nominal Voltage
1.5 V
5.Average Weight
1.2 g
6.Typical Capacity
80 mAh
Condition: Rated at 15KΩ at 21℃, continuous discharge to end-point voltage 0.9V.
7.Electrical Characteristics
Item Resistance Fresh Battery (Within 30 After 12 months Test Conditions
days after delivery)
Off-load Voltage - 1.52V~1.65V 1.50V~1.60V Temp:21℃
On-load Voltage 15KΩ 1.50V~1.60V 1.48V~1.60V Temp:21℃
8.Discharge Performance
Discharge Conditions Minimum Average Duration
Resistance Discharge End-point Environmental Conditions Fresh Battery After 12 Months
Schedule Voltage
15KΩ Continuous 0.9V Temp:21℃ 970h 880h
9. Safety Characteristics
Test Item Condition Period Requirements Acceptance Standard
External Short Circuit Temp:20±5℃ 24h There shall be no N=9
explosion of battery Ac=0
Re=1
page 2 of 4
Product Specification 产品规格书 LR1130 0.%Hg
10.Marking
The following marking will be printed, stamped or impressed on the body of the battery:
a. Designation:LR1130 or AG10
b. Polarity marking:“+” Marked on anode, “-“ Marked on cathode
11. Cautions
11.1 Storage
Batteries shall be stored in well-ventilated, dry and cool conditions. For normal storage, the temperature
should be between 10°C and 25°C and should never exceed 30°C, the relative humidity should be at
(55±20)%. High temperature or high humidity may cause deterioration of the battery performance or
surface corrosion.
(2) Batteries should not be short-circuited, heated, dismantled and thrown into fire.
(3) Do not charge batteries. Attempting to charge a non-rechargeable battery may cause internal gas
and/or heat generation resulting in leakage, explosion and may cause personal injury.
(4) Do not mix old and new batteries or batteries of different types or brands. When replacing batteries,
replace all of them at the same time with new batteries of the same brand and type. When batteries
of different brand or type are used together, or new and old batteries are used together, some
batteries may be over-discharged due to a difference of voltage or capacity. This can result in leakage,
explosion and may cause personal injury.
(5) Exhausted batteries should be immediately removed from equipment and properly disposed of. When
discharged batteries are kept in the equipment for a long time, electrolyte leakage may occur causing
damage to the appliance and/or personal injury.
(6) Do not weld or solder directly to batteries. The heat from welding or soldering directly to a battery
may cause internal short-circuiting resulting in leakage, explosion and may cause personal injury.
(7) Keep batteries out of the reach of children to prevent swallow. In case of ingestion of a cell or a
battery, the person involved should seek medical assistance promptly.
(8) Store unused batteries in their original packaging away from metal objects. If already unpacked, do
not mix or jumble batteries to avoid them short-circuiting with each other.
page 3 of 4
Product Specification 产品规格书 LR1130 0.%Hg
page 4 of 4