0% found this document useful (0 votes)
78 views1 page

A-3.21 - UNIT B1 PLANS AND INTERIOR ELEVATIONS Rev.17 Markup

The document provides notes and symbols for unit plans. It specifies details like towel bar heights and toilet paper dispenser locations. The total number of units is 60 with 2 bedrooms and 2 baths per unit. Interior elevations are included for cabinet layout.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
78 views1 page

A-3.21 - UNIT B1 PLANS AND INTERIOR ELEVATIONS Rev.17 Markup

The document provides notes and symbols for unit plans. It specifies details like towel bar heights and toilet paper dispenser locations. The total number of units is 60 with 2 bedrooms and 2 baths per unit. Interior elevations are included for cabinet layout.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

GENERAL UNIT NOTES SYMBOL LEGEND - UNIT PLANS UNIT TYPE - B1

1. PLEASE NOTE - MIRRORED VERSION OF UNIT LAYOUTS MAY BE USED IN BUILDING PLANS - REFER TO A-4.00 DRAWINGS 19. ALL TOWEL BARS ARE TO BE MOUNTED AT 48" AFF AS INDICATED ON PLANS. TOILET PAPER DISPENSERS AT 18" AFF UNLESS NOTED OTHERWISE (IN TYPE A
X WINDOW TAG SYMBOL CLEAR FLOOR SPACE WITH 2"
TOTAL # OF UNITS ON SITE: 60 Drawn By: HPA
2. REFER TO MEP DWGS FOR LOCATION OF SMOKE, CO & FIRE DETECTORS. UNITS, MOUNT 7-9" HORIZONTALLY BEYOND FRONT EDGE OF WC).
TOLERANCE AREA TOTAL NUMBER OF BEDROOMS : 2 Checked By: MK
3. REFER ALSO TO SHEET A1.02 FOR ABBREVIATIONS AND GENERAL PROJECT NOTES. 20. INTERIOR ELEVATIONS ARE FOR SCHEMATIC CABINET LAYOUT ONLY. CONTRACTOR TO VERIFY ALL DIMENSIONS. PROVIDE FILLERS AS REQUIRED, FILLERS X DOOR TAG SYMBOL
4. REFER ALSO TO SHEET A1.05 FOR TYPICAL WALL ASSEMBLIES. SHALL BE A MAXIMUM OF 3"
REFER TO NOTES FOR REQUIRED TOTAL NUMBER OF BATH : 2 Date Plotted: 30 June 2022
DIMENSIONS
5. REFER ALSO TO THE A2.00 SERIES SHEET SHEETS FOR DOOR AND WINDOW SCHEDULE & DETAILS. 21. VANITY MIRRORS TO BE 42" HIGH AND 2" LESS THAN THE VANITY WIDTH (TYP) AND TO BE MOUNTED WITH THE BOTTOM OF THE REFLECTING SURFACE NO MORE X
DETAIL SECTION TAG
OCCUPANCY PER UNIT : 6 Issue Dates:
3
6. ALL INTERIOR DOORS SHALL ALLOW A MINIMUM OF 4" AIRFLOW FOR RETURN AIR AT BOTTOM OF DOOR. THAN 40" AFF IN ANSI TYPE A UNITS.
A-5.01
DROPPED SOFFITS (RE PLAN FOR DEPTH TRAVEL DISTANCE (IN UNIT) = 57'-2"
AND LOCATION)
7. EXTERIOR WINDOWS SHALL MEET ALL FEDERAL, STATE & LOCAL GLAZING STANDARDS. SLIDING GLASS DOORS SHALL NOT HAVE PIN LOCKS OR CHARLEY BARS. 22. VERIFY ALL FIXTURE DIMENSIONS WITH ACTUAL TUB/SHOWER PROVIDED. GC TO COORDINATE FINAL FRAMING W/TUB/SHOWER MFR AND DETAILS. INSTALL 1
DETAIL REFERENCE TAG 1 HOUR RATED WALLS
8. PER IBC-2018 TABLE 1022.2(1), ONLY STORIES PERMITTED TO HAVE A SINGLE EXIT ARE ALSO REQUIRED TO HAVE EMERGENCY ESCAPES OPENINGS. WHEN CONTINUOUS BASE LAYER OF GYPBD AT ALL RATED WALLS BEFORE TUB/SHOWER FIXTURE INSTALLTION ON RATED WALLS A3.01 SQUARE FOOTAGE DATA
Issue for Pricing / Bidding:
REQUIRED, EMERGENCY ESCAPES OPENINGS TO BE PROVIDED IN BEDROOMS SHALL HAVE A MINIMUM OF ONE OPENING WITH 20" NET CLEAR WIDTH, 24" NET 23. PROVIDE SOLID BLOCKING IN ALL WALLS FOR FUTURE INSTALLATION OF GRAB BARS AS SHOWN ON A1.03, OR PROVIDE AN ALTERNATIVE MEANS OF # ELECTRIC PANEL NET ACSF: 1163 SF
CLEAR HEIGHT, 5.7 SQFT. NET CLEAR OPENABLE AREA AND SHALL BE 44" MAXIMUM FROM FINISH FLOOR TO TOP OF SILL. ALL OTHER UNITS WITH AT LEAST TWO REINFORCING THE CAVITY BETWEEN THE TUB/SHOWER ENCLOSURES AND THE WALL. INTERIOR ELEVATION SYMBOL FIRE EXTINGUISHER - PROVIDE 2A:10B:C
# A3.01 # FE Issue for Permit Application:
DISTINCT EXIT PATHS FROM THE UNIT ENTRY DOOR DO NOT REQUIRE EMERGENCY ESCAPE OPENINGS. 24. SEE ARCHITECTURAL ELEVATION, MEP AND STRUCTURAL DRAWINGS FOR EXTERIOR FEATURES THAT MAY REQUIRE BLOCKING OR OTHER CONSIDERATIONS IN EACH UNIT (COORD W/OWNER) AND IN PATIO/BALCONY: 67 SF
7. WALL TYPES INSIDE UNIT PERIMETER ARE INDICATED ON THE A-3.00 UNIT PLANS. REFER TO A-4.00 BUILDING PLANS FOR PERIMETER WALL TYPES (UNIT TO SPECIFIC TO THE UNIT LOCATION IN THE BUILDING, SUCH AS BUT NOT LIMITED TO ATTACHED SIGNAGE, LIGHTING, AWNINGS, CANOPIES, TRELLISES, SHUTTERS, # BREEZEWAY/CORRIDORS OR AS
APPROVED BY AHJ TOTAL GSF: 1230 GSF Issue for Construction:
UNIT, UNIT TO CORRIDOR, UNIT TO EXTERIOR). FIXTURES, BUILDOUTS, CORNICES, RAILINGS, LANDSCAPE FEATURES AND ADJACENT ATTACHED STRUCTURES. 1A PARTITION WALL TAG
8. ALL DIMENSIONS ARE TO FACE OF STUD OR CENTER LINE OF OPENING. U.N.O. FOR DIMENSIONING PURPOSES, TYPICAL STUD WALLS ARE DIMENSIONED AS 31 2" 25. PROVIDE A HIGH OUTLET AT 46" AFF FOR WALL MOUNT TV IN LIVING AND BEDROOMS. PROVIDE 2x10 BLOCKING FOR TV MOUNTING. REF A1.05
THICK AND PLUMBING WALLS AS 51 2" THICK. 26. ALL EXTERIOR SLABS TO SLOPE DOWN MIN 1 8" PER 1'-0" TO EXTERIOR EDGE OF SLAB. LIGHT BROOM FINISH AT SLOPED SURFACES. VERIFY WITH STRUCTURE. VP CPT Revisions:
FLOORING TRANSITION TAG
9. ALL "NON DIMENSIONED" DOOR LOCATIONS SHALL BE LOCATED MIN 3" (DOUBLE STUD JAMB) FROM CORNER 27. REFER TO INTERIOR DESIGNER ROOM FINISH SCHEDULE AND SOM FOR FINISHES, FOR ADDITIONAL ROOM FINISH NOTES . # DATE COMMENTS
10. REFER ALSO TO UNIT PLANS AND STRUCTURAL DRAWINGS FOR 2X6 WALL LOCATIONS. 28. REFER TO INTERIOR DESIGNER DRAWINGS FOR EXACT MOLDING LOCATIONS, SIZES AND FINISHES. AHU = AIR HANDLER UNIT LIN = LINEN CABINET TR = TOWEL RING
CO = CASED OPENING MC = MEDICINE CABINET @ 44" AFF V = VINYL
NOTE: UNITS MAY BE OPPOSITE 1 7-6-2022 COORDINATION DRAWING
11. PROVIDE MOISTURE RESISTANT GYPSUM DRYWALL AT ALL BATHROOM WALLS. 29. ALL GROUND FLOOR WINDOWS FACING AND OPEN TO THE POOL COURTYARD MUST BE LIMITED TO 4" OPENING.
30. ALL WINDOWS IN GROUP R-2 AND R-3 OCCUPANICES LOCATED ABOVE THE FIRST FLOOR WITH SILLS BELOW 36" AFF, MUST HAVE FALL PROTECTION IN CPT = CARPET P = PANTRY VP = VINYL PLANK HAND. SEE BUILDING PLANS FOR
12. IN LEED PROJECTS DRYWALL NEEDS TO BE NON PAPER BASED
13. PROVIDE SOUND BATTS IN ALL CORRIDOR, TENANT SEPARATION, LAUNDRY ROOM, PLUMBING, AND HVAC CLOSET WALLS ACCORDANCE WITH IBC SECTION 1015.8 (LIMITING OPENING TO 4" AND/OR CONTROL DEVICES PER ASTM F 2090)
CSR = CURVED SHOWER ROD RH = ROBE HOOK W = WASHER LOCATIONS. SEE ELEVATIONS FOR
CT = CERAMIC TILE SH = SHOWER HEAD W/D = WASHER / DRYER LOCATION OF EXTERIOR FINISHES.
14. REFER TO STRUCTURAL DRAWINGS FOR SHEARWALL AND BEARING WALL LOCATIONS 31. ALL FIRST FLOOR PATIOS AND BALCONIES OPENING TO THE POOL DECK AREA SHALL HAVE 48" HIGH RAILINGS.
D = CLOTHES DRYER SR = SHOWER ROD WH = WATER HEATER
15. VERTICAL MECHANICAL CHASES WITHIN UNITS ARE TO BE FIRE STOPPED PER LOCAL REQUIREMENTS. 32. ALTHOUGH SYMBOLS HAVE BEEN REMOVED FOR CLARITY, ALL FLOOR FINISHES SHALL EXTEND UNDER SHELVING, APPLIANCES, ALL RAISED COUNTERS, DESKS
DWR = DRAWER SRO = SHEETROCK OPENING WS = WORKSPACE
16. ALL ANGLES ARE 45° TO HORIZONTAL & VERTICAL DIRECTIONS, UNLESS NOTED OTHERWISE, TYPICAL AT ALL UNITS. AND ANY CABINETS INDICATED WITH "REMOVABLE FRONTS". DW = DISHWASHER T = TEMPERED GLASS #S = # OF SHELVES
NOTE:
17. ALL DIMENSIONS AND NOTES STATING "CLEAR" ARE FROM FACE OF FINISH TO FACE OF FINISH OR CABINET/FIXTURE. 33. ACCESSIBLE DIMENSIONS LABELED “CLR” “MIN” “MAX” ARE FROM FINISHED FACE TO FINISHED FACE. GYPBD = GYPSUM BOARD TB = TOWEL BAR 1R1S = DENOTES 1 ROD/ 1 SHELF ALL INTERIOR WALLS TO BE 31
18. REFER TO A1.03 AS A REFERENCE FOR UNIT FAIR HOUSING ACT GUIDELINES (FHAG) REQUIREMENTS AND OTHER ACCESSIBILITY REQUIREMENTS. 34. THE 18 INCHES FROM THE CENTERLINE OF THE TOILET TO THE FINISHED WALL OR ADJACENT TUB/SHOWER IS AN ABSOLUTE MEASUREMENT. KS = KNEE SPACE TP = TOILET PAPER DISPENSER 2R2S = DENOTES 2 RODS/ 2 SHELVES UNLESS OTHERWISE NOTED. C 2022 by Humphreys & Partners Architects LP All Rights
REVISION HISTORY DESCRIPTION REFER TO FLOOR PLANS FOR Reserved
REV. DESCRIPTION EXTERIOR AND BREEZEWAY WALL The architectural works depicted herein are the sole property
1 REMOVED TILE AT KITCHEN ELEVATION AND ADDED of Humphreys & Partners Architects, L.P. and may not be
BACKSPLASH, SWING DR IN AT BEDRM 1 WIC, RELOCATED
TAGS. 400 SERIES SHEETS. constructed or used without its express written permission. No
SH AT BATH 1, REMOVED TILE BATH SURROUND, ADDED permission to modify or reproduce any of the architectural
COUNTERTOP THICKNESS works, including without limitation the construction of any
building, is expressed or should be implied from delivery of
preliminary drawings or unsealed construction drawings.
Permission to construct the building depicted in sealed
BATH VANITY LIGHT BATH VANITY LIGHT FILLER FILLER FILLER construction drawings is expressly conditioned on the full and
timely payment of all fees otherwise due Humphreys &
TUB SURROUND WALL Partners Architects, L.P. and, in the absence of any written
INTEGRATED
TUB SURROUND WALL
INTEGRATED W1542 W3624 W3942 W3624-24 W1842 W3024 W2442
agreement to the contrary, is limited to a one-time use on the
WITH INTEGRATED WITH INTEGRATED
SHELVES BACKER BOARD FOR SHELVES site indicated on these plans.
BACKER BOARD FOR
SH FUTURE GRAB BARS FUTURE GRAB BARS CSR

3'-6"

3'-6"
OPEN TO
VINYL COATED MIRROR CSR MIRROR PROVIDE MIN 2X10 LIVING/DINING
WIRE SHELF 30"X40" 30"X40" BLOCKING FOR MICRO

3'-6"
RFI 9

3'-4"
DOOR AS FUTURE GRAB
9'-0"

9'-0"

9'-0"

9'-0"

9'-0"

9'-0"

9'-0"
TILE TILE
SCHEDULED
7'-6"

1'-6"

1'-6"
7'-4"

7'-4"
6'-10"
LAV LAV 1

2'-10" GRAB BAR

CROSSPOINTE AT KILLIAN, LLC


4"

4"
2'-10" GRAB BAR

2'-10" GRAB BAR

CrossPointe
5'-0"

2'-10"

2'-10"

3'-0"

3'-0"

3'-0"
TP
1'-6"

1'-6"
TP

1'-6"

CSC DEVELOPMENT
COLUMBIA, SOUTH CAROLINA
DRYER WASHER 38X60 SHOWER VBD12 VB33 VBD12 RFI 9 RFI 9 VB33 VBD12 B27 B27 B15 SB36 DW B15 REF P219624 DB418 RANGE B24
DRYER BOX WASHER BOX 30"X60" 30"X60" GRANITE FILLER GRANITE FILLER FILLER GRANITE END PANEL GRANITE GRANITE FILLER
(HEAD WALL) 18" CLR GRANITE FILLER 18" CLR
HOOK UP HOOK UP (FOOT WALL) 1 (HEAD WALL) 1 COUNTERTOP COUNTERTOP COUNTERTOP COUNTERTOP BACKSPLASH
15" MIN CLR
CL
COUNTERTOP 15" MIN CLR
CL
RFI 15 GRANITE
PROVIDE MIN 2X10 PROVIDE MIN 2X10 RFI 15 1 BACKSPLASH 24" MIN CLR 24" MIN CLR
BLOCKING FOR BLOCKING FOR NOTE: ALL COUNTERTOPS TO BE 2CM RFI 15 1
RFI 15 1 NOTE: ALL COUNTERTOPS TO BE 2CM PROVIDE BLOCKING AND PROVIDE BLOCKING AND NOTE: ISLAND COUNTER TOP TO BE 3CM CL
AT KITCHEN AND BATH LOCATIONS
CL
FUTURE GRAB FUTURE GRAB
AT KITCHEN AND BATH LOCATIONS GRAB AT FIRST FLOOR ONLY GRAB AT FIRST FLOOR ONLY

LAUNDRY ELEVATION BATH 1 ELEVATION BATH 2 ELEVATION BATH 2 ELEVATION BATH 2 ELEVATION KITCHEN ELEVATION KITCHEN ELEVATION KITCHEN ELEVATION
13 SCALE: 1/4"=1'-0"
12 SCALE: 1/4"=1'-0"
11 SCALE: 1/4"=1'-0"
10 SCALE: 1/4"=1'-0"
9 SCALE: 1/4"=1'-0"
8 SCALE: 1/4"=1'-0"
7 SCALE: 1/4"=1'-0"
6 SCALE: 1/4"=1'-0"

CL CL
39'-0"

15" MIN CLR 18" CLR 16'-421" 12'-321"


10'-4"

3'-6" 3'-5" 3'-2" 3'-2" 3'-121" 1'-11" 8'-5" 6'-234" 6'-034"


MIN 42" HT AFF METAL
GUARDRAIL B
2x6 WALL

1'-821"

2'-0"
1HR
C C C PATIO/BALCONY
CONC BEDROOM 2

1HR
2x6 WALL
OFF 24" MAX CLR 24" MIN CLR

9'-1" CLG

1HR
CPT
DINING

4'-0"
2x6 WALL

2x6 WALL

1HR

541 EAST HORATIO AVE - STE 100 MAITLAND, FL 32751


9'-1" CLG

4'-8"
5'-5"
VP

1HR
LC

SLOPE
3'-021"

11'-221"

11'-221"

PARTNERS
3'-5" 3'-7"

1HR
VP CONC

DALLAS - ORLANDO -NEWPORT - NEW ORLEANS -CHICAGO -


A
1/4" 2 A

NEW YORK - SAN RAMON - SCOTTSDALE - EDMONTON -


T

ARCHITECTS / FLORIDA LLC


1HR

TORONTO - CHENNAI - DUBAI - HANOI - MONTEVIDEO


2x6 WALL

15'-621"
15'-6"
1HR

(407) 339 9323 (407) 339 8266 FAX


13'-1121"
4'-921" 4'-021"

1HR
LC LIVING 23'-8" 3'-0"

5'-1"

CERTIFICATE #AA 0003227


9'-1" CLG 6

1HR
VP EP
RFI 15

9'-921"
1HR
2x6 WALL

VP CPT

1HR
5

621"
9'-421"
.

11'-0"
1HR
5S
WIC

2R2S
UNIT B1 CFS LAUNDRY PLAN UNIT B1 CFS BATH PLAN
.

4'-4"

4'-4"
1HR
5 4

3'-1121"

3'-921"
9'-1" CLG

1R1S
SCALE: 3/8"=1'-0" SCALE: 3/8"=1'-0" TYPE B BATHROOM OPTION B

HUMPHREYS
CPT 5'-921" 2'-021" 6'-121" 5'-221" 2'-121" 7'-021"

1HR
1'-9" 3'-8" 1'-9"
1R1S

1HR
5'-934" 2x6 WALL 2x6 WALL

1HR

33'-6"

33'-6"
1R1S 5

1HR

1'-8"
LAV

3'-734"
CPT VP
2x6 WALL

2x6 WALL WC

5'-521"
1HR

5'-321"
TP

5'-10"
WIC 9
"
2R2S

R2

2'-6"

135
BATH 2

1HR

7'-621"
9'-1" CLG 5 DW
5S

°
CPT 9'-1" CLG

9'-021"
5'-
1HR
A-3.21 10

3 16
VP "

5
TB

1HR
3'-621" 8
3'-534"

(40" MIN CLR) SINK W/

6'-5"
6

1HR
DISPOSAL 135

1'-821"
4'-1"
KITCHEN 5S SR °
7 A-3.21

1HR
SH 11
A-3.21
9'-1" CLG
8169 "

5'-021"

1'-
RFI 15 1 VP
R2

1'-6"

1'-6"
1HR

5
48
GARDEN TUB
"

"

17'-1121"
18'-0"
141" 141" BEDROOM 1 6 135

PERMIT SET 06-03-2022


3 NICHE °
1HR

2'-
3'-734" (40" MIN CLR)

1'-1"
9'-1" CLG RANGE /

8 16
1'-821" 5'-534"

3 "
2'-6"
A-3.21
CL CPT MICRO/ CAB 1HR

B REF 4 MANEUVERING
PANTRY
RFI 15
HOOD 4

4'-1"
9'-
1'-
1HR

5S CLEARANCE

58
1 "
10
12'-621"

3'-121"
24" MIN CLR

A-3.21

"
AT DOOR
F:\2022 Projects\2022005 Sila Capital - The Killian\04 DRAWINGS\2022005A321.dwg

6'-4"
1'-
TB
BATH 1 SHOWER 1

11 2
LAUNDRY
SHOWER DOOR

1 "
5 9'-1" CLG 9'-1" CLG SHEET CONTENTS:

1'-
A-3.21
VP

5'-434"

13 6
61
VP W "
VP 4'-11167 "

7'-6"
CPT VP

2'-3"
7
UNIT B1 PLANS AND

°
1R1S

NC

135
2x6 WALL

1'-
CO

8"
12
INTERIOR ELEVATIONS

3
4'-821"
1HR

WC 6

16"
3'-121" 3'-921" 2'-221" 2'-121"

3'-913
D 13 A-3.21 6'-2" 2'-4" 9'-4" 3'-9" 3'-9" 2'-5"
LAV SH
1HR

WH/AHU

2'-7"

2'-7"

2'-7"
TP

1'-441"
1R1S SHEET NO.
1HR

1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR

RFI 15 1
13'-1" 8'-334" 3'-441" 5'-1121" 3'-9" 4'-621"

A-3.21
NOTE: 5
A-3.21
PROVIDE GRABS AT SHOWER
24" MIN CLR PER FFPC 101:30.2.1 (REFER 24'-9" 14'-3"
24" MAX OFFSET TO DETAIL 1/A-1.03)
CL CL 39'-0"

UNIT B1 CFS KITCHEN PLAN UNIT B1 - REFERENCE PLAN UNIT B1 - DIMENSION PLAN
3 2 1
SCALE: 3/8"=1'-0" SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-0"
2022005

You might also like