Jerv Works Const. Ref: Reinforced Concrete Structures, Pg. 149 By: R. Park & T. Paulay Circular Column
Jerv Works Const. Ref: Reinforced Concrete Structures, Pg. 149 By: R. Park & T. Paulay Circular Column
CIRCULAR COLUMN
(for short compression member only)
By Whitney Formula
Column no. b1
specification
fc' 22 MPa
fy 414 Mpa
structural system
unbraced against sidesway
service load
unfactored Dead load 80 kN
unfactored Live load 90 kN
load eccentricity, e 30 cm
column
Lu, unsupported height 4 m column is over designed by 36.62%
h, diameter (min. 25 cm.) 40 cm OK - acceptable
conc. cover in. (min. 1.5 in.) 4 cm
~ capacity reduction factor 0.7
e = 30 cm.
h = 40 cm.
cl
REMARKS:
1. column property : Tension Controls
h = 40 cm. Slenderness critical
2. column ultimate capacity = 418.112 kN
3. % of reinforcement 2.35%
4. OK - r-bar spacing
calculation
converted to U.S. unit
fc' 3190.66 psi
fy 60042.42 psi
unfactored Dead load 17.9856 kips
unfactored Live load 20.2338 kips
load eccentricity, e 11.811 in.
Lu, unsupported height 13.12 ft.
h, diameter (min. 10 in..) 15.748 in.
conc. cover in. (min. 1.5 in.) 1.5748 in.
check e
col. min. e = .05h 0.7874 in.
or min e = 1 1 in.
or actual e = 11.811 in.
final e 11.811 in.
30 cm
check slenderness effect
k = effective length factor 1
klu = effective length 13.12 ft.
r radius of gyration = .25h 3.937 in.
klu/r 39.98984 ft.
when, braced against sidesway 34-12M1/M2
M1 lesser moment 1
M2 larger moment 1
22 22 >> 39.98984
Slenderness critical
reinforcing bars
main bar area in^2 dia. In. spiral wire area in^2 dia. In.
16mm 0.3122 0.6304 10mm 0.1219 0.394
20mm 0.4878 0.788 12mm 0.1756 0.4728
25mm 0.7636 0.985 16mm 0.3122 0.6304
28mm 0.9559 1.1032 0.1219 0.394
32mm 1.2485 1.2608
0.7636 0.985
structural system k
braced against sidesway 1 22 34-12M1/M2
unbraced against sidesway 1 22 22
22 22