Building Drift Analysis
Building Drift Analysis
PAGE NO. 1
****************************************************
* *
* STAAD.Pro V8i SELECTseries6 *
* Version 20.07.11.33 *
* Proprietary Program of *
* Bentley Systems, Inc. *
* Date= NOV 13, 2020 *
* Time= 8:33:55 *
* *
* USER ID: *
****************************************************
1. STAAD SPACE
INPUT FILE: C:\Users\ejhun\Desktop\2 Storey House\Two Storey Residence\Two-Storey Residence-Design.STD
2. START JOB INFORMATION
3. ENGINEER DATE 06-SEP-20
4. END JOB INFORMATION
5. INPUT WIDTH 79
6. UNIT METER KN
7. JOINT COORDINATES
8. 2 3.75 1.8 0; 3 7.5 1.8 0; 4 0 1.8 2; 5 3.75 1.8 2; 6 7.5 1.8 2; 7 0 1.8 5
9. 8 3.75 1.8 5; 9 7.5 1.8 5; 10 0 1.8 8; 11 3.75 1.8 8; 12 7.5 1.8 8
10. 13 0 1.8 12; 14 3.75 1.8 12; 15 7.5 1.8 12; 16 2.332 1.8 12; 17 3.75 1.8 13.2
11. 18 2.332 1.8 13.2; 19 3.75 0 0; 20 7.5 0 0; 21 0 0 2; 22 3.75 0 2; 23 7.5 0 2
12. 24 0 0 5; 25 3.75 0 5; 26 7.5 0 5; 27 0 0 8; 28 3.75 0 8; 29 7.5 0 8
13. 30 0 0 12; 31 3.75 0 12; 32 7.5 0 12; 33 2.332 0 12; 34 3.75 0 13.2
14. 35 2.332 0 13.2; 36 3.75 4.8 0; 37 7.5 4.8 0; 38 0 4.8 2; 39 3.75 4.8 2
15. 40 7.5 4.8 2; 41 0 4.8 5; 42 3.75 4.8 5; 43 7.5 4.8 5; 44 0 4.8 8
16. 45 3.75 4.8 8; 46 7.5 4.8 8; 47 0 4.8 12; 48 3.75 4.8 12; 49 7.5 4.8 12
17. 50 2.332 4.8 12; 53 0 7.8 2; 54 3.75 7.8 2; 55 7.5 7.8 2; 56 0 7.8 5
18. 57 3.75 7.8 5; 58 7.5 7.8 5; 59 0 7.8 8; 60 3.75 7.8 8; 61 7.5 7.8 8
19. 62 0 7.8 12; 63 3.75 7.8 12; 66 3.75 4.2 12; 67 2.332 4.2 12; 68 3.75 4.2 13.2
20. 69 2.332 4.2 13.2; 70 2.6 4.8 2; 71 0 4.8 4; 72 2.6 4.8 5; 73 2.6 4.8 4
21. 76 2.55 4.8 0; 77 7.5 5.7 0; 78 7.5 4.8 13.2; 79 3.75 4.8 13.2
22. 80 4.5 4.8 13.2; 81 5.25 4.8 13.2; 82 6 4.8 13.2; 83 6.75 4.8 13.2
23. 84 4.5 4.8 12; 85 5.25 4.8 12; 86 6 4.8 12; 87 6.75 4.8 12; 88 7.5 6 12
24. 90 7.5 7.8 0.8; 92 0 8.7 5; 94 0 8.7 8; 96 0 8.7 12; 97 3.75 9.6 5
25. 98 3.75 9.6 8; 99 3.75 9.6 12; 100 7.5 9 2; 101 7.5 9 5; 102 7.5 9 8
26. 103 0 7.8 0.8; 104 -0.9 4.8 5; 105 -0.9 4.8 8; 106 -0.9 4.8 5.75
27. 107 -0.9 4.8 6.5; 108 -0.9 4.8 7.25; 109 0 4.8 5.75; 110 0 4.8 6.5
28. 111 0 4.8 7.25; 118 0 4.8 9.425; 119 3.75 4.8 9.425; 120 7.5 4.8 9.425
29. 121 3.75 7.8 9.425; 122 7.5 7.8 9.425; 123 0 4.8 12.75; 124 3.75 4.8 12.75
30. 125 0 7.8 12.75; 126 3.75 7.8 12.75
31. MEMBER INCIDENCES
32. 2 2 3; 4 2 5; 5 3 6; 6 4 5; 7 5 6; 8 4 7; 9 5 8; 10 6 9; 11 7 10; 12 8 11
33. 13 9 12; 14 10 13; 15 11 14; 16 12 15; 17 7 8; 18 8 9; 19 10 11; 20 11 12
34. 21 13 16; 22 14 15; 23 16 14; 24 14 17; 25 16 18; 26 18 17; 27 19 2; 28 20 3
35. 29 21 4; 30 22 5; 31 23 6; 32 24 7; 33 25 8; 34 26 9; 35 27 10; 36 28 11
36. 37 29 12; 38 30 13; 39 31 14; 40 32 15; 41 33 16; 42 34 17; 43 35 18; 44 2 36
37. 45 3 37; 46 4 38; 47 5 39; 48 6 40; 49 7 41; 50 8 42; 51 9 43; 52 10 44
38. 53 11 45; 54 12 46; 55 13 47; 56 14 66; 57 15 49; 58 16 67; 59 36 37; 60 36 39
*** NOTE: MASS MODEL FORMED WILL BE USED IN SEISMIC/RESPONSE/TIME HISTORY LOADING, IF ANY.
IF MASS MODEL IS SEPARATELY PROVIDED IN INDIVIDUAL LOADING, THE GENERATED MASS
WILL BE REPLACED BY THE MASS PROVIDED IN INDIVIDUAL LOADING.
************************************************************************************
NO. TYPE FL. LEVEL FL. WT CENTRE OF MASS MASTER JOINT NO.
X Z
************************************************************************************
131. R1 1.0
132. DEFINE WIND LOAD
133. TYPE 1 WIND 1
134. INT 1.3323 1.3323 1.3323 1.3323 HEIG 3 6 7.2 7.8
135. EXP 1 JOINT 2 TO 50 53 TO 63 66 TO 73 76 TO 88 90 92 94 96 TO 111 118 TO 126
136. LOAD 1 LOADTYPE SEISMIC TITLE EX
137. UBC LOAD X 1 DEC 1 ACC 0.05
138. PERFORM ANALYSIS
P R O B L E M S T A T I S T I C S
-----------------------------------
1 1.80 OK OK
2 4.80 OK OK
3 7.80 OK OK
***********************************************************
* *
* X DIRECTION : Ta = 0.399 Tb = 0.509 Tuser = 0.000 *
* T = 0.509, LOAD FACTOR = 1.000 *
* UBC TYPE = 97 *
* UBC FACTOR V = 0.1294 x 2331.64 = 301.74 KN *
* *
***********************************************************
************************************************************************
STORY LEVEL DYN. ECC. (dec) ACC. ECC. (aec) DESIGN ECC.
----- ----- --------------- --------------- ---------------
X Z X Z X Z
dec + aec dec + aec
************************************************************************
139. CHANGE
140. LOAD 2 LOADTYPE SEISMIC TITLE EZ
141. UBC LOAD Z 1 DEC 1 ACC 0.05
142. PERFORM ANALYSIS
***********************************************************
* *
* Z DIRECTION : Ta = 0.399 Tb = 0.491 Tuser = 0.000 *
* T = 0.491, LOAD FACTOR = 1.000 *
* UBC TYPE = 97 *
* UBC FACTOR V = 0.1294 x 2331.64 = 301.74 KN *
* *
***********************************************************
************************************************************************
STORY LEVEL DYN. ECC. (dec) ACC. ECC. (aec) DESIGN ECC.
----- ----- --------------- --------------- ---------------
X Z X Z X Z
dec + aec dec + aec
************************************************************************
143. CHANGE
144. LOAD 3 LOADTYPE DEAD TITLE DL
145. REFERENCE LOAD
146. R1 -1.0
147. LOAD 4 LOADTYPE LIVE TITLE LL
148. FLOOR LOAD
149. _PORCH FLOAD 1.9 GY
**NOTE** about Floor/OneWay Loads/Weights.
Please note that depending on the shape of the floor you may
have to break up the FLOOR/ONEWAY LOAD into multiple commands.
For details please refer to Technical Reference Manual
Section 5.32.4.2 Note d and/or "5.32.4.3 Note f.
************************************************************
************************************************************
386. FINISH
************************************************************
* For technical assistance on STAAD.Pro, please visit *
* http://selectservices.bentley.com/en-US/ *
* *
* Details about additional assistance from *
* Bentley and Partners can be found at program menu *
* Help->Technical Support *
* *
* Copyright (c) 1997-2015 Bentley Systems, Inc.
* http://www.bentley.com *
************************************************************