Scope CC 2664
Scope CC 2664
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 1 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Permanent Facility
ELECTRO-
TECHNICAL-
Using 6½ Digit
Alternating AC Current @ 50 Hz
1 Precision Multimeter 100 µA to 400 mA 0.120 % to 0.126 %
Current (< 1 & 1 kHz
by Direct Method
GHz)
(Measure)
ELECTRO-
TECHNICAL-
Using 6½ Digit
Alternating AC Current @ 50 Hz
2 Precision Multimeter 400 mA to 10 A 0.126 % to 0.136 %
Current (< 1 & 1 kHz
by Direct Method
GHz)
(Measure)
ELECTRO-
TECHNICAL-
Using 6½ Digit
Alternating AC Voltage @ 50 Hz
3 Precision Multimeter 1 mV to 100 mV 1.3 % to 0.076 %
Current (< 1 & 1 kHz
by Direct Method
GHz)
(Measure)
ELECTRO-
TECHNICAL-
Using 6½ Digit
Alternating AC Voltage @ 50 Hz
4 Precision Multimeter 1 V to 1000 V 0.070 % to 0.074 %
Current (< 1 & 1 kHz
by Direct Method
GHz)
(Measure)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 2 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
TECHNICAL-
Using 6½ Digit
Alternating AC Voltage @ 50 Hz
5 Precision Multimeter 100 mV to 1 V 0.076 % to 0.070 %
Current (< 1 & 1 kHz
by Direct Method
GHz)
(Measure)
ELECTRO-
TECHNICAL-
Using 6½ Digit
Alternating
6 Capacitance DC Precision Multimeter 0.5 nF to 100 nF 3.854 % to 1.32 %
Current (< 1
by Direct Method
GHz)
(Measure)
ELECTRO-
TECHNICAL-
Using 6½ Digit
Alternating
7 Capacitance DC Precision Multimeter 100 µF to 10 mF 1.411 % to 1.17 %
Current (< 1
by Direct Method
GHz)
(Measure)
ELECTRO-
TECHNICAL-
Using 6½ Digit
Alternating
8 Capacitance DC Precision Multimeter 100 nF to 100 µF 1.32 % to 1.411 %
Current (< 1
by Direct Method
GHz)
(Measure)
ELECTRO- Using Multi Product
TECHNICAL- Calibrator Fluke
AC Current @ 50 Hz
9 Alternating 5502E with 50T 20.0 A to 1000 A 0.956 % to 0.956 %
& 1 kHz
Current (< 1 Current Coil by
GHz) (Source) Direct Method
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 3 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
Using Multi Product
TECHNICAL-
AC Current @ 50 Hz Calibrator Fluke
10 Alternating 3.3 A to 10 A 0.144 % to 0.147 %
& 1 kHz 5502E by Direct
Current (< 1
Method
GHz) (Source)
ELECTRO-
Using Multi Product
TECHNICAL-
AC Current @ 50 Hz Calibrator Fluke
11 Alternating 30 µA to 329.9 µA 0.348 % to 0.290 %
& 1 kHz 5502E by Direct
Current (< 1
Method
GHz) (Source)
ELECTRO-
Using Multi Product
TECHNICAL-
AC Current @ 50 Hz Calibrator Fluke 329.9 µA to 329.9
12 Alternating 0.290 % to 0.097 %
& 1 kHz 5502E by Direct mA
Current (< 1
Method
GHz) (Source)
ELECTRO-
Using Multi Product
TECHNICAL-
AC Current @ 50 Hz Calibrator Fluke
13 Alternating 329.9 mA to 3.3 A 0.097 % to 0.144 %
& 1 kHz 5502E by Direct
Current (< 1
Method
GHz) (Source)
ELECTRO-
Using Multi Product
TECHNICAL-
AC Voltage @ 50 Hz Calibrator Fluke
14 Alternating 1 mV to 329.9 mV 0.233 % to 0.116 %
& 1 kHz 5502E by Direct
Current (< 1
Method
GHz) (Source)
ELECTRO-
Using Multi Product
TECHNICAL-
AC Voltage @ 50 Hz Calibrator Fluke
15 Alternating 3.3 V to 1000 V 0.039 % to 0.059 %
& 1 kHz 5502E by Direct
Current (< 1
Method
GHz) (Source)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 4 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
Using Multi Product
TECHNICAL-
AC Voltage @ 50 Hz Calibrator Fluke
16 Alternating 329.9 mV to 3.3 V 0.116 % to 0.039 %
& 1 kHz 5502E by Direct
Current (< 1
Method
GHz) (Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Capacitance @ 1 Calibrator Fluke
17 Alternating 0.5 nF to 329 nF 0.597 % to 0.293 %
kHz 5502E by Direct
Current (< 1
Method
GHz) (Source)
ELECTRO-
TECHNICAL- Using Decade
18 Alternating Inductance @ 1 kHz Inductance Box by 100 µH to 1 H 0.653 % to 0.98 %
Current (< 1 Direct Method
GHz) (Source)
ELECTRO-
TECHNICAL- Using 6½ Digit
19 DIRECT DC Current Precision Multimeter 10 µA to 100 µA 1.187 % to 0.072 %
CURRENT by Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using 6½ Digit
20 DIRECT DC Current Precision Multimeter 100 µA to 400 mA 0.072%
CURRENT by Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using 6½ Digit
21 DIRECT DC Current Precision Multimeter 400 mA to 10 A 0.072 % to 0.183 %
CURRENT by Direct Method
(Measure)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 5 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
TECHNICAL- Using 6½ Digit
22 DIRECT DC Voltage Precision Multimeter 1 mV to 100 mV 0.685 % to 0.07 %
CURRENT by Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using 6½ Digit
23 DIRECT DC Voltage Precision Multimeter 1 V to 1000 V 0.071 % to 0.07 %
CURRENT by Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using 6½ Digit
24 DIRECT DC Voltage Precision Multimeter 100 mV to 1 V 0.07 % to 0.071 %
CURRENT by Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using 6½ Digit
25 DIRECT Resistance Precision Multimeter 0.1 Ohm to 100 Ohm 0.048 % to 0.4 %
CURRENT by Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using 6½ Digit
100 kOhm to 1000
26 DIRECT Resistance Precision Multimeter 0.013 % to 1.35 %
MOhm
CURRENT by Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using 6½ Digit
100 Ohm to 100
27 DIRECT Resistance Precision Multimeter 0.4 % to 0.013 %
kOhm
CURRENT by Direct Method
(Measure)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 6 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
Using Multi Product
TECHNICAL-
Calibrator Fluke
28 DIRECT DC Current 1 µA to 329.9 µA 0.20 % to 0.018 %
5502E by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Calibrator Fluke
29 DIRECT DC Current 2.9 A to 10.9 A 0.05 % to 0.70 %
5502E by Direct
CURRENT
Method
(Source)
ELECTRO- Using Multi Product
TECHNICAL- Calibrator Fluke
30 DIRECT DC Current 5502E with 50T 20.0 A to 1000 A 0.92 % to 0.92 %
CURRENT Current Coil by
(Source) Direct Method
ELECTRO-
Using Multi Product
TECHNICAL-
Calibrator Fluke
31 DIRECT DC Current 329.9 mA to 2.9 A 0.013 % to 0.05 %
5502E by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Calibrator Fluke 329.9 µA to 329.9
32 DIRECT DC Current 0.018 % to 0.013 %
5502E by Direct mA
CURRENT
Method
(Source)
ELECTRO-
TECHNICAL- Using Low
33 DIRECT DC Resistance Resistance Jig by 1 k ohm 0.154%
CURRENT Direct Method
(Source)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 7 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
TECHNICAL- Using Low
34 DIRECT DC Resistance Resistance Jig by 1 m ohm 2.119%
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using Low
35 DIRECT DC Resistance Resistance Jig by 1 ohm 0.15%
CURRENT Direct Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Calibrator Fluke 10 m Ohm to 329.9
36 DIRECT DC Resistance 6.123 % to 0.011 %
5502E by Direct Ohm
CURRENT
Method
(Source)
ELECTRO-
TECHNICAL- Using Low
37 DIRECT DC Resistance Resistance Jig by 10 k ohm 0.154%
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using Low
38 DIRECT DC Resistance Resistance Jig by 10 m ohm 0.582%
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using Low
39 DIRECT DC Resistance Resistance Jig by 10 ohm 0.156%
CURRENT Direct Method
(Source)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 8 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
TECHNICAL- Using Low
40 DIRECT DC Resistance Resistance Jig by 100 m ohm 2.313%
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using Low
41 DIRECT DC Resistance Resistance Jig by 100 ohm 0.154%
CURRENT Direct Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Calibrator Fluke 329.9 k ohm to 1100
42 DIRECT DC Resistance 0.014 % to 1.804 %
5502E by Direct M ohm
CURRENT
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Calibrator Fluke 329.9 Ohm to 329.9
43 DIRECT DC Resistance 0.011 % to 0.015 %
5502E by Direct kOhm
CURRENT
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Calibrator Fluke
44 DIRECT DC Voltage 1 mV to 329.9 mV 0.062 % to 0.007 %
5502E by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Calibrator Fluke
45 DIRECT DC Voltage 3.3 mV to 1000 mV 0.006%
5502E by Direct
CURRENT
Method
(Source)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 9 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
Using Multi Product
TECHNICAL-
Calibrator Fluke
46 DIRECT DC Voltage 329.9 mV to 3.3 V 0.007 % to 0.006 %
5502E by Direct
CURRENT
Method
(Source)
ELECTRO-
TECHNICAL- Using High
47 DIRECT High Resistance Resistance Jig by 1 G ohm 2.319%
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using High
48 DIRECT High Resistance Resistance Jig by 10 G ohm 2.361%
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using High
49 DIRECT High Resistance Resistance Jig by 10 M ohm 2.36%
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using High
50 DIRECT High Resistance Resistance Jig by 100 G ohm 3.81%
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using High
51 DIRECT High Resistance Resistance Jig by 100 M ohm 2.312%
CURRENT Direct Method
(Source)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 10 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
TECHNICAL- Using High
52 DIRECT High Resistance Resistance Jig by 1000 G ohm 5.519%
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using High
53 DIRECT High Resistance Resistance Jig by 200 M ohm 2.342%
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using High
54 DIRECT High Resistance Resistance Jig by 5 M ohm 5.94%
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using High
55 DIRECT High Resistance Resistance Jig by 500 M ohm 2.316%
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using 6½ Digit
56 TEMPERATURE RTD (PT-100) Precision Multimeter -200 °C to 800 °C 0.04°C
SIMULATION by Direct Method
(Measure)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (B Calibrator Fluke
57 TEMPERATURE 600 °C to 1800 °C 0.177°C
Type) 5502E by Direct
SIMULATION
Method
(Measure)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 11 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (E Calibrator Fluke
58 TEMPERATURE -250 °C to 1000 °C 0.464°C
Type) 5502E by Direct
SIMULATION
Method
(Measure)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (J Calibrator Fluke
59 TEMPERATURE -200 °C to 1200 °C 0.12°C
Type) 5502E by Direct
SIMULATION
Method
(Measure)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (K Calibrator Fluke
60 TEMPERATURE -200 °C to 1370 °C 0.123°C
Type) 5502E by Direct
SIMULATION
Method
(Measure)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (N Calibrator Fluke
61 TEMPERATURE -200 °C to 1300 °C 0.131°C
Type) 5502E by Direct
SIMULATION
Method
(Measure)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (R Calibrator Fluke
62 TEMPERATURE 2 °C to 1760 °C 0.309°C
Type) 5502E by Direct
SIMULATION
Method
(Measure)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (S Calibrator Fluke
63 TEMPERATURE 2 °C to 1760 °C 0.283°C
Type) 5502E by Direct
SIMULATION
Method
(Measure)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 12 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (T Calibrator Fluke
64 TEMPERATURE -250 °C to 400 °C 0.166°C
Type) 5502E by Direct
SIMULATION
Method
(Measure)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (U Calibrator Fluke
65 TEMPERATURE -200 °C to 600 °C 0.123°C
Type) 5502E by Direct
SIMULATION
Method
(Measure)
ELECTRO-
Using Multi Product
TECHNICAL-
RTD (PT-100-385 Calibrator Fluke
66 TEMPERATURE -200 °C to 800 °C 0.041°C
Type) 5502E by Direct
SIMULATION
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
RTD (PT-1000-385 Calibrator Fluke
67 TEMPERATURE -200 °C to 630 °C 0.041°C
Type) 5502E by Direct
SIMULATION
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (B Calibrator Fluke
68 TEMPERATURE 600 °C to 1800 °C 0.16°C
Type) 5502E by Direct
SIMULATION
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (E Calibrator Fluke
69 TEMPERATURE -250 °C to 1000 °C 0.46°C
Type) 5502E by Direct
SIMULATION
Method
(Source)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 13 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (J Calibrator Fluke
70 TEMPERATURE -200°C to 1200°C 0.12°C
Type) 5502E by Direct
SIMULATION
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (K Calibrator Fluke
71 TEMPERATURE -200 °C to 1370 °C 0.122°C
Type) 5502E by Direct
SIMULATION
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (N Calibrator Fluke
72 TEMPERATURE -200 °C to 1300 °C 0.13°C
Type) 5502E by Direct
SIMULATION
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (R Calibrator Fluke
73 TEMPERATURE 2 °C to 1760 °C 0.309°C
Type) 5502E by Direct
SIMULATION
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (S Calibrator Fluke
74 TEMPERATURE 2 °C to 1760 °C 0.287°C
Type) 5502E by Direct
SIMULATION
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (T Calibrator Fluke
75 TEMPERATURE -250 °C to 400 °C 0.153°C
Type) 5502E by Direct
SIMULATION
Method
(Source)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 14 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (U Calibrator Fluke
76 TEMPERATURE -200 °C to 600 °C 0.124°C
Type) 5502E by Direct
SIMULATION
Method
(Source)
ELECTRO-
TECHNICAL- Using 6½ Digit
77 TIME & Frequency Precision Multimeter 10 Hz to 100 kHz 0.012 % to 0.013 %
FREQUENCY by Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Time
Time Interval / Stop
78 TIME & Calibrator by Direct / 1 Sec to 10800 Sec 0.1 Sec to 4.88 Sec
Watch / Timer
FREQUENCY Comparison Method
(Measure)
ELECTRO-
TECHNICAL- Using Time
Time Interval / Stop 10800 Sec to 86400 4.88 Sec to 36.891
79 TIME & Calibrator by Direct /
Watch / Timer Sec Sec
FREQUENCY Comparison Method
(Measure)
ELECTRO-
Using Multi Product
TECHNICAL-
Calibrator Fluke
80 TIME & Frequency 1 Hz to 500 kHz 10.2 % to 1.68 %
5502E by Direct
FREQUENCY
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Calibrator Fluke
81 TIME & Frequency 500 kHz to 2 MHz 1.68%
5502E by Direct
FREQUENCY
Method
(Source)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 15 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Anemometer,
FLUID FLOW- Velocity Sensor with
Using Hot wire
FLOW indicator, Hot Wire
82 Anemometer By 0.5 m/s to 22 m/s 4.23%
MEASURING Anemometer,
Comparison Method
DEVICES Capture Hood, Vane
Type Anemometer
Rotameter, Flow
FLUID FLOW- Using Air Flow
Mater, Gas Flow
FLOW Calibrator / Gas Flow
83 Meter, Dry Gas 0.5 LPM to 25 LPM 12.73 % to 2 %
MEASURING Analyzer by
Meter, Flow Rate
DEVICES Comparison method
Measuring Meters
Rotameter, Flow
FLUID FLOW- Using Air Flow
Mater, Gas Flow
FLOW Calibrator / Gas Flow
84 Meter, Dry Gas 25 LPM to 100 LPM 2.2%
MEASURING Analyzer by
Meter, Flow Rate
DEVICES Comparison method
Measuring Meters
MECHANICAL- Using Vibration
Amplitude/ Vibration
85 ACCELERATION meter By 1 m/s2 to 30 m/s2 3.8%
Meter Acceleration
AND SPEED Comparison Method
MECHANICAL- Using Vibration
Amplitude/ Vibration
86 ACCELERATION meter By 1 mm/s to 65 mm/s 3.8%
Meter Velocity
AND SPEED Comparison Method
MECHANICAL- Using Vibration
Amplitude/ Vibration
87 ACCELERATION meter By 0.05 mm to 0.6 mm 3.8%
Meter Displacement
AND SPEED Comparison Method
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 16 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Non-Contact
Tachometer Speed /
MECHANICAL- RPM Indicator of
Using tachometer by
88 ACCELERATION Washing M/c, Speed 10 rpm to 8000 rpm 0.36%
comparison method:
AND SPEED / RPM Indicator
Drying M/c L.C. 1
rpm and coarser
Non-Contact
Tachometer Using Digital
Stroboscope / Tachometer &
MECHANICAL-
Speedo Meter Source By 10 rpm to 100000
89 ACCELERATION 0.36%
/Stirrer / RPM Source Comparison method rpm
AND SPEED
/ Vibrating M/c / with using motorized
Abrasion Testing M/c source with strip:
/ Centrifuge
Non-Contact
Tachometer
Tachometer, RPM Stroboscope /
MECHANICAL-
Meter, Speedo Speedo Meter 10 rpm to 10000
90 ACCELERATION 0.36%
Meter, Centrifuge, /Stirrer / RPM Source rpm
AND SPEED
Contact Type / Vibrating M/c /
Abrasion Testing M/c
/ Centrifuge
Using Sound
MECHANICAL- Sound Level Meter
91 Calibrator by 114 dB 1.1 dB
ACOUSTICS @ 1 kHz
Comparison Method
Using Sound
MECHANICAL- Sound Level Meter
92 Calibrator by 94 dB 1.1 dB
ACOUSTICS @ 1 kHz
Comparison Method
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 17 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
MECHANICAL-
DIMENSION
Bevel Protractor / Using Angle Gauges
(BASIC
93 Inclinometer / by Comparison (0 - 90 - 0) ° 4.5min
MEASURING
Clinometer L.C 1 min Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
Bore Dial Gauge
DIMENSION Using Universal
(Transmission
(BASIC Length Measuring
94 Accuracy Check 0 to 1 mm 2.1µm
MEASURING Machine by
Only) L.C 0.001 mm
INSTRUMENT, Comparison Method
and Coarser
GAUGE ETC.)
MECHANICAL-
"Using Caliper
DIMENSION
Caliper (Vernier / Checker, & Slip
(BASIC
95 Digital/ Dial ) 0.01 Gauge Set by 0 to 300 mm 11µm
MEASURING
mm and Coarser Comparison Method
INSTRUMENT,
"
GAUGE ETC.)
MECHANICAL-
"Using Caliper
DIMENSION
Caliper (Vernier / Checker, & Slip
(BASIC
96 Digital/ Dial) 0.01 Gauge Set by 0 to 600 mm 12.5µm
MEASURING
and Coarser Comparison Method
INSTRUMENT,
"
GAUGE ETC.)
MECHANICAL-
"Using Caliper
DIMENSION Caliper (Vernier /
Checker, & Slip
(BASIC Digital/ Dial) L.C
97 Gauge Set by 0 to 1000 mm 15µm
MEASURING 0.01 mm and
Comparison Method
INSTRUMENT, Coarser
"
GAUGE ETC.)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 18 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
MECHANICAL-
DIMENSION
Coating Thickness Using Master Foils
(BASIC
98 Gauge 0.1µm and by Comparison Up to 1 mm 3.3µm
MEASURING
Coarser Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Combination Set Using Angle Gauges
(BASIC
99 /Degree Protractor by Comparison 0 ° to 180 ° 45 min of arc
MEASURING
(L.C.: 1°) Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION Depth Caliper "Using Slip Gauge
(BASIC (Vernier / Digital/ Set Caliper Checker
100 0 to 300 mm 12.31 µm
MEASURING Dial) L.C 0.01 mm & Accessories by
INSTRUMENT, and Coarser Comparison Method"
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Universal
(BASIC Dial Gauge Lever L.C Length Measuring
101 0 to 1 mm 2.1µm
MEASURING 1 µm and Coarser Machine by
INSTRUMENT, Comparison Method
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Universal
Dial Gauge Plunger
(BASIC Length Measuring
102 L.C 0.1µm and 0 to 25 mm 1.8µm
MEASURING Machine by
Coarser
INSTRUMENT, Comparison Method
GAUGE ETC.)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 19 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
MECHANICAL-
DIMENSION
Dial Thickness Using Grade “0” Slip
(BASIC
103 Gauge L.C. : 0.001 Gauges, by 0 to 10 mm 1.1µm
MEASURING
mm Comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION External / Outside
"Using Slip Gauge
(BASIC Micrometer L.C
104 Set by Comparison 0 to 25 mm 1.1µm
MEASURING 0.001 mm and
Method"
INSTRUMENT, Coarser
GAUGE ETC.)
MECHANICAL-
DIMENSION External / Outside Using Slip Gauge
(BASIC Micrometer L.C Set, & Length Bar
105 25 mm to 100 mm 2.5µm
MEASURING 0.001 mm and Cylinder Master by
INSTRUMENT, Coarser Comparison Method
GAUGE ETC.)
MECHANICAL-
DIMENSION External / Outside
Using Slip Gauge
(BASIC Micrometer L.C
106 Set, & Length Bar by 300 mm to 600 mm 8.4µm
MEASURING 0.001 mm and
Comparison Method
INSTRUMENT, Coarser
GAUGE ETC.)
MECHANICAL-
DIMENSION External / Outside "Using Slip Gauge
(BASIC Micrometer L.C Set , Length Bar & 600 mm to 1000
107 12.7µm
MEASURING 0.001 mm and Accessories by mm
INSTRUMENT, Coarser Comparison Method"
GAUGE ETC.)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 20 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
MECHANICAL-
DIMENSION
External / Outside "Using Slip Gauge
(BASIC
108 Micrometer L.C. Set & Length bar by 100 mm to 300 mm 4.22µm
MEASURING
0.001 mm Comparison Method"
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION Universal length
(BASIC Feeler Gauge / measuring machine
109 0 to 1 mm 1.3µm
MEASURING Master Foils by Comparison
INSTRUMENT, Method
GAUGE ETC.)
MECHANICAL-
"Using Slip Gauge
DIMENSION Height Gauge
Set, Surface Plate &
(BASIC (Vernier, Dial,
110 Caliper Checker by 0 to 600 mm 14µm
MEASURING Digital) 0.001 mm
Comparison Method
INSTRUMENT, Coarser
"
GAUGE ETC.)
MECHANICAL-
DIMENSION Height Gauge "Using Surface Plate
(BASIC (Vernier, Dial, & Caliper Checker
111 0 to 1000 mm 16.2µm
MEASURING Digital) L.C 0.01 mm by Comparison
INSTRUMENT, and Coarser Method "
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Slip Gauge Set
Inside Dial Caliper
(BASIC /Caliper Checker &
112 L.C. 0.025 mm & 10 mm to 35 mm 19.6µm
MEASURING Accessories by
Coarser
INSTRUMENT, Comparison Method
GAUGE ETC.)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 21 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
MECHANICAL-
Internal Micrometer Using Slip Gauge Set
DIMENSION
(traverse) L.C. 0.01 /Length Bar / caliper
(BASIC
113 mm & Coarser checker and 5 mm to 1000 mm 14.2µm
MEASURING
(Extension not more Accessories by
INSTRUMENT,
than 1000 mm) Comparison Method
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Scale
(BASIC Measuring Tape / Pie (161 x SQRT of L) (L
114 Calibrator by 0 to 50 m
MEASURING Tape L.C. : 1 mm in meter.)µm
Comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Universal
(BASIC
115 Pin Gauge Length Measuring 0.15 mm to 50 mm 0.81µm
MEASURING
Machine
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Grade “0” Slip
(BASIC Pistol Caliper L.C. :
116 Gauges, by 0 to 90 mm 66.5µm
MEASURING 0.1 mm and Coarser
Comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Universal
(BASIC Plain Plug Gauge , length Measuring
117 100 mm to 300 mm 4.9µm
MEASURING Setting Plug , Machine by
INSTRUMENT, Comparison Method
GAUGE ETC.)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 22 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
MECHANICAL-
DIMENSION Using Universal
Plain Plug Gauge,
(BASIC length Measuring
118 Setting Plug Gauge, 0.15 mm to 100 mm 2.5µm
MEASURING Machine by
Width Gauge,
INSTRUMENT, Comparison Method
GAUGE ETC.)
MECHANICAL-
Using Universal
DIMENSION
Length Measuring
(BASIC Plain Ring Gauge,
119 Machine with Master 3 mm to 300 mm 4.6µm
MEASURING Setting Ring Gauge
Ring Gauge by
INSTRUMENT,
Comparison Method
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Video
Radius Gauge
(BASIC Measuring Machine
120 (concave and 1 mm to 25 mm 10.8 µm
MEASURING by Comparison
convex profiles)
INSTRUMENT, Method
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Universal
(BASIC Snap Gauge / Gap Length Measuring
121 2.5 mm to 100 mm 2.9µm
MEASURING Gauge / C & I Type Machine by
INSTRUMENT, Comparison Method
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Universal
(BASIC Snap Gauge, Gap Length Measuring
122 100 mm to 200 mm 3.2µm
MEASURING Gauge, (C & I Type) Machine by
INSTRUMENT, Comparison Method
GAUGE ETC.)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 23 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
MECHANICAL-
DIMENSION Using Video
(BASIC Standard Wire Measuring Machine
123 0.17 mm to 8 mm 6.6µm
MEASURING Gauge by Comparison
INSTRUMENT, Method
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Tape & Scale
(BASIC Steel Scale L.C 1 +/- (160 x SQRT of L
124 Calibrator by Up to 1000 mm
MEASURING mm ) µm(L in mtr.)
Comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Video
(BASIC Measuring Machine
125 Test Sives 0.075 mm to 10 mm 6.8µm
MEASURING by Comparison
INSTRUMENT, Method
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Digital Caliper
(BASIC
126 Test Sives by Comparison 50 mm to 100 mm 79µm
MEASURING
Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Universal
(BASIC Thread Measuring Length Measuring 0.17 mm to 6.35
127 0.7µm
MEASURING Wires Machine by mm
INSTRUMENT, Comparison Method
GAUGE ETC.)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 24 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
MECHANICAL-
DIMENSION Using Video
(BASIC Thread Pitch Gauge Measuring Machine
128 Up to 90 ° 6.0min. of arc
MEASURING (Angle) by Comparison
INSTRUMENT, Method
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Video
(BASIC Thread Pitch Gauge Measuring Machine
129 0.4 mm to 6 mm 8.7µm
MEASURING (Pitch) by Comparison
INSTRUMENT, Method
GAUGE ETC.)
MECHANICAL-
Measuring Wires
DIMENSION Thread Plug Gauge
with Universal
(BASIC (W.C.P. /C.P./Setting
130 Length Measuring 100 mm to 300 mm 5.3µm
MEASURING Plug) Major Dia
Machine by
INSTRUMENT, Effective Dia
Comparison Method
GAUGE ETC.)
MECHANICAL-
Measuring Wires
DIMENSION Thread Plug Gauge
with Universal
(BASIC (W.C.P. /C.P./Setting
131 Length Measuring 3 mm to 100 mm 2.63µm
MEASURING Plug) Major Dia
Machine by
INSTRUMENT, Effective Dia
Comparison Method
GAUGE ETC.)
MECHANICAL-
Using Universal
DIMENSION
Thread Ring Gauge Length Measuring
(BASIC
132 (WCR/CR) Effective Machine with Master 3 mm to 300 mm 4.6µm
MEASURING
Dia Ring Gauge by
INSTRUMENT,
Comparison Method
GAUGE ETC.)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 25 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
MECHANICAL-
DIMENSION
Using Slip Gauge Set
(BASIC Ultrasonic Thickness
133 by Comparison 0 to 100 mm 16.1µm
MEASURING Gauge L.C 0.01 mm
Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Video
(BASIC Measuring Machine
134 Weld Gauge- Angle 0 ° to 90 ° 12.8min
MEASURING with Comparison
INSTRUMENT, Method
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Video
(BASIC Weld Gauge- Depth Measuring Machine
135 0 to 25 mm 86µm
MEASURING Measurment & Slip Gauge Set by
INSTRUMENT, Comparison Method
GAUGE ETC.)
MECHANICAL- Length Bar / Long Using Universal
DIMENSION Gauge Block Length Measuring
136 25 mm to 400 mm 1.25 µm
(PRECISION /Micrometer Setting Machine by
INSTRUMENTS) Standard Comparison Method
MECHANICAL- Length Bar / Long Using Slip gauge set
DIMENSION Gauge Block / Length bar and Dial 400 mm to 1100
137 9.1µm
(PRECISION /Micrometer Setting Gauge 0.1µm by mm
INSTRUMENTS) Standard Comparison Method
Using Shore
Rubber Hardness
MECHANICAL- Hardness Tester 10 Shore A to 100
138 Tester: Spring Force 1.78Shore A
DUROMETER Calibrator as per Shore A
Calibration
ASTM D 2240-15
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 26 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Using Shore
Rubber Hardness
MECHANICAL- Hardness Tester 10 Shore D to 100
139 Tester: Spring Force 1.78Shore D
DUROMETER Calibrator as per Shore D
Calibration
ASTM D 2240-15
MECHANICAL- Using Digital
Barometer, Abs.
PRESSURE Pressure 150 mbar to 1500
140 Pressure Gauge 1.2mbar
INDICATING Gauge(Abs.) By mbar
/Manometer
DEVICES Comparison Method
Hydraulic Pressure
Digital & Dial
Pressure Gauge,
Pressure Using Automatic
MECHANICAL-
Transmitter, Pressure Calibrator
PRESSURE
141 Pressure Switch, By Comparison 0 to 20 bar 0.008bar
INDICATING
Pressure Calibrator method as per DKD
DEVICES
/Manometer R-6-1
/Pressure
Transmitter
Differential
Hydraulic-Pressure
Using Digital
Dial and Digital
MECHANICAL- Pressure Gauge and
Pressure Gauges,
PRESSURE Pressure
142 Pressure 0 to 1000 bar 0.8bar
INDICATING Comparator By
Transmitters,
DEVICES Comparison method
Pressure Switch,
as per DKD-R-6-1
Pressure Calibrator
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 27 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Hydraulic-Pressure
Dial and Digital
MECHANICAL- Using Pressure
Pressure Gauges,
PRESSURE Calibrator By
143 Pressure 0 to 400 bar 0.098bar
INDICATING Comparision Method
Transmitters,
DEVICES as per DKD R-6-1
Pressure Switch,
Pressure Calibrator
Hydraulic-Pressure
(Master Pressure
MECHANICAL- Using Pressure
Gauge, Pressure
PRESSURE Calibrator By
144 Calibrator, Pressure 0 to 700 bar 0.1bar
INDICATING Comparision Method
Transducer,
DEVICES as per DKD R-6-1
Pressure
Transmitter)
Pneumatic Pressure
Digital & Dial
Pressure Gauge,
MECHANICAL- Using Pressure
Pressure
PRESSURE Calibrator By
145 Transmitter, 0 to 35 bar 0.005bar
INDICATING Comparison method
Pressure Switch,
DEVICES as per DKD R-6-1
Pressure Calibrator,
Pressure Transmitter
Differential
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 28 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Pneumatic Pressure
Digital & Dial
Pressure Gauge,
Using Digital
MECHANICAL- Pressure
Pressure Calibrator
PRESSURE Transmitter, -40 mbar to +40
146 By Comparison 0.1mbar
INDICATING Manometers, mbar
Method using DKD
DEVICES Magnehelic Gauge,
R-6-1 / 2
Pressure
Calibrator,Pressure
Switch
Pneumatic Pressure
Digital & Dial
Pressure Gauge,
Using Automatic
MECHANICAL- Pressure
Pressure Calibrator
PRESSURE Transmitter,
147 By Comparison 0 to 1 bar 0.0012bar
INDICATING Pressure Switch,
method as per DKD
DEVICES Manometers,
R-6-1
Pressure Calibrator,
Pressure Transmitter
Differential
Pneumatic Pressure
Digital & Dial
MECHANICAL- Using Pressure
Pressure Gauge,
PRESSURE Calibrator By
148 Pressure 0 to 7 bar 0.004bar
INDICATING Comparison method
Transmitter,
DEVICES as per DKD R-6-1
Pressure Switch,
Pressure Calibrator
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 29 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Using Digital
MECHANICAL- Vacuum Dial / Digital Vacuum Indicator &
PRESSURE Gauges, Vacuum vacuum Comparator
149 -0.99 to 0 bar 0.008bar
INDICATING Calibrator & Vacuum By Comparison
DEVICES Transmitters Method as per DKD
R-6-1
Using weighing
balance of d : 0.001
mg, Distilled water
MECHANICAL-
150 Micropipette Calibration of Micro 1 µl to 10 µl 0.06µl
VOLUME
pipettes based on
Gravimetric Method
as per ISO 8655-6
Using weighing
balance of d : 0.001
mg, Distilled water
MECHANICAL-
151 Micropipette Calibration of Micro 10 µl to 100 µl 0.3µl
VOLUME
pipettes based on
Gravimetric Method
as per ISO 8655-6
Using weighing
balance of d : 0.001
mg, Distilled water
MECHANICAL-
152 Micropipette Calibration of Micro 100 µl to 1000 µl 0.78µl
VOLUME
pipettes based on
Gravimetric Method
as per ISO 8655-6
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 30 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Using weighing
Volume Glassware balance of d :0.01
Pipette, Burette, mg, Distilled water
MECHANICAL-
153 Measuring cylinder, Calibration of Micro 1 ml to 100 ml 0.1ml
VOLUME
Volumetric flask & pipettes based on
Bottle Top Dispenser Gravimetric Method
as per ISO 4787
Using Weighing
balance with d : 10
Volume Glassware
mg respectively &
Pipette, Burette,
MECHANICAL- distilled water
154 Measuring cylinder, 100 ml to 1000 ml 0.5ml
VOLUME Calibration of
Volumetric flask &
Glassware based on
Bottle Top Dispenser
Gravimetric method
as per ISO 4787
Using Weighing
balance with d : 10
Volume Glassware
mg, respectively &
Pipette, Burette,
MECHANICAL- distilled water
155 Measuring cylinder, 1000 ml to 5000 ml 1.3ml
VOLUME Calibration of
Volumetric flask &
Glassware based on
Bottle Top Dispenser
Gravimetric method
as per ISO 4787
Using E1 & E2 Class
MECHANICAL-
Electronics Weighing weights. Weighing
WEIGHING
156 Balances Readability Balance of Class 2 100 mg to 1 kg 9mg
SCALE AND
: 0.001 g and Coarser as per
BALANCE
OIML R-76-1
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 31 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Using F1 Class
MECHANICAL-
Electronics Weighing weights. Weighing
WEIGHING
157 Balances Readability Balance of Class III 1g to 20 kg 100 mg
SCALE AND
: 0.1 g and Coarser as per
BALANCE
OIML R-76-1
Using F2 Class
MECHANICAL-
Electronics Weighing weights up to 100kg.
WEIGHING
158 Balances Readability Weighing Balance of 100 g to 100 kg 10g
SCALE AND
: 10 g Class 3 and Coarser
BALANCE
as per OIML R-76-1
Using F1 Class
MECHANICAL- weights up to 100
Electronics Weighing
WEIGHING kg. Weighing
159 Balances Readability 5g to 50 kg 2g
SCALE AND Balance of Class 3
:2g
BALANCE and Coarser as per
OIML R-76-1
Using E1 & E2 Class
MECHANICAL-
Electronics Weighing weights. Weighing
WEIGHING
160 Balances Readability Balance of Class I 1 mg to 200 g 0.06mg
SCALE AND
:0.01 mg and Coarser as per
BALANCE
OIML R-76-1
Using E1 / E2 Class
MECHANICAL-
Electronics Weighing weights up to 200 g.
WEIGHING
161 Balances Readability Weighing Balance of 1mg g to 80 g 0.04mg
SCALE AND
0.01 mg Class I and Coarser
BALANCE
as per OIML R-76-1
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 32 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 33 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Using F2 Class
Weights and
MECHANICAL- Mass-Weight M1 Precision balance of
166 50 kg 2g
WEIGHTS Class or Coarser 2 g readability as
per ABBA method .
OIML-R111
Using E1 Class
Standard Weights
and Precision
Balance of
MECHANICAL- Mass-Weights E2 Readability: 0.01 mg
167 10 g 0.03mg
WEIGHTS Class and Coarser method of Weighing
and “ABBA”
Weighing Cycle
Procedure based on
OIML R 111 (2004)
Using E1 Class
Standard Weights
and Precision
Balance of
Readability: 0.001
MECHANICAL- Mass-Weights E2
168 mg method of 10 mg 0.002mg
WEIGHTS Class and Coarser
Weighing and
“ABBA” Weighing
Cycle Procedure
based on OIML R
111 (2004)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 34 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Using E1 Class
Standard Weights
and Precision
Balance of
MECHANICAL- Mass-Weights E2 Readability: 0.01 mg
169 100 g 0.04mg
WEIGHTS Class and Coarser method of Weighing
and “ABBA”
Weighing Cycle
Procedure based on
OIML R 111 (2004)
Using E1 Class
Standard Weights
and Precision
Balance of
Readability: 0.001
MECHANICAL- Mass-Weights E2
170 mg method of 1mg 0.002mg
WEIGHTS Class and Coarser
Weighing and
“ABBA” Weighing
Cycle Procedure
based on OIML R
111 (2004)
Using E1 Class
Standard Weights
and Precision
Balance of
Readability: 0.001
MECHANICAL- Mass-Weights E2
171 mg method of 2g 0.002mg
WEIGHTS Class and Coarser
Weighing and
“ABBA” Weighing
Cycle Procedure
based on OIML R
111 (2004)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 35 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Using E1 Class
Standard Weights
and Precision
Balance of
MECHANICAL- Mass-Weights E2 Readability: 0.01 mg
172 20 g 0.03mg
WEIGHTS Class and Coarser method of Weighing
and “ABBA”
Weighing Cycle
Procedure based on
OIML R 111 (2004)
Using E1 Class
Standard Weights
and Precision
Balance of
Readability: 0.001
MECHANICAL- Mass-Weights E2
173 mg method of 20 mg 0.002mg
WEIGHTS Class and Coarser
Weighing and
“ABBA” Weighing
Cycle Procedure
based on OIML R
111 (2004)
Using E1 Class
Standard Weights
and Precision
Balance of
MECHANICAL- Mass-Weights E2 Readability: 0.01 mg
174 200 g 0.08mg
WEIGHTS Class and Coarser method of Weighing
and “ABBA”
Weighing Cycle
Procedure based on
OIML R 111 (2004)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 36 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Using E Class
Standard Weights
and Precision
Balance of
Readability: 0.001
MECHANICAL- Mass-Weights E2
175 mg method of 5 mg 0.002mg
WEIGHTS Class and Coarser
Weighing and
“ABBA” Weighing
Cycle Procedure
based on OIML R
111 (2004)
Using E1 Class
Standard Weights
and Precision
Balance of
MECHANICAL- Mass-Weights E2 Readability: 0.01 mg
176 50 g 0.03mg
WEIGHTS Class and Coarser method of Weighing
and “ABBA”
Weighing Cycle
Procedure based on
OIML R 111 (2004)
Using E1 Class
Standard Weights
and Precision
Balance of
Readability: 0.001
MECHANICAL- Mass-Weights E2
177 mg method of 2 mg 0.004mg
WEIGHTS Class or Coarser
Weighing and
“ABBA” Weighing
Cycle Procedure
based on OIML R
111 (2004)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 37 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Using E1 Class
Standard Weights
and Precision
Balance of
Readability: 0.001
MECHANICAL- Mass-Weights
178 mg method of 1g 0.004mg
WEIGHTS E2Class or Coarser
Weighing and
“ABBA” Weighing
Cycle Procedure
based on OIML R
111 (2004)
Using F1 Class
Weights and
MECHANICAL- Mass-Weights M1 Precision balance of
179 1000 g 8mg
WEIGHTS Class and coarse 1 mg readability as
per ABBA method .
OIML-R111 (2004)
Using F1 Class
Weights and
MECHANICAL- Mass-Weights M1 Precision balance of
180 2 kg 10mg
WEIGHTS Class Coarser 10 mg readability as
per ABBA method .
OIML-R111 (2004)
Using F1 Class
Weights and
MECHANICAL- Mass-Weights M1 Precision balance of
181 5 kg 20mg
WEIGHTS Class Coarser 10 mg readability as
per ABBA method .
OIML-R111(2004)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 38 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Using E2 Class
Weights and
MECHANICAL- Mass-Weights M1 Precision balance of
182 500 g 8mg
WEIGHTS Class or Coarser 1 mg readability as
per ABBA method .
OIML-R111 (2004)
Using E1 Class
Standard Weights
and Precision
Balance of
Readability: 0.001
MECHANICAL- Mass-Weights E2
183 mg method of 100 mg 0.002mg
WEIGHTS Class and Coarser
Weighing and
“ABBA” Weighing
Cycle Procedure
based on OIML R
111 (2004)
Using E1 Class
Standard Weights
and Precision
Balance of
Readability: 0.001
MECHANICAL- Mass-Weights E2
184 mg method of 200 mg 0.002mg
WEIGHTS Class and Coarser
Weighing and
“ABBA” Weighing
Cycle Procedure
based on OIML R
111 (2004)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 39 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Using E1 Class
Standard Weights
and Precision
Balance of
Readability: 0.001
MECHANICAL- Mass-Weights E2
185 mg method of 50 mg 0.002mg
WEIGHTS Class and Coarser
Weighing and
“ABBA” Weighing
Cycle Procedure
based on OIML R
111 (2004)
Using E1 Class
Standard Weights
and Precision
Balance of
Readability: 0.001
MECHANICAL- Mass-Weights E2
186 mg method of 500 mg 0.003mg
WEIGHTS Class and Coarser
Weighing and
“ABBA” Weighing
Cycle Procedure
based on OIML R
111 (2004)
Dial/Digital & Analog Using Humidity
THERMAL- Thermo-Hygrometer/ Chamber & Digital
187 SPECIFIC HEAT RH Sensors/ with RH & Temperature 15 %RH to 95 %RH 1.68%RH
& HUMIDITY indicator / Recorder/ indicator with
Data logger @25°C Sensor probe
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 40 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 41 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
"Temp. Transmitter,
RTD/PT-100 Sensor
(Thermocouple with
& Without Using Low
Controller/Indicator) Temperature Bath
THERMAL- Data Logger, Temp. With SPRT And
191 -30 °C to 50 °C 0.4°C
TEMPERATURE Calibrator Temp. Precision
Recorder, Temp. Temperature
Switch, Temp. Scanner
Gauge, Digital
Thermometer & Dry-
Wet Thermome
Comparison using
Infrared
Black Body with
Thermometer,
THERMAL- Emissivity (0.95)
192 Thermal Image, 50 °C to 500 °C 3.25°C
TEMPERATURE Source with Using
Radiation
Infrared
Pyrometer,
Thermometer
Using Low
Temperature
THERMAL- Liquid In Glass
193 Ethanol Bath With -30 °C to 50 °C 0.46°C
TEMPERATURE Thermometers
SPRT And Precision
Tempreture Scanner
Using Silicon Oil
THERMAL- Liquid In Glass Bath With SPRT And
194 50 °C to 250 °C 0.39°C
TEMPERATURE Thermometers Precision
Tempreture Scanner
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 42 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Temp. Transmitter,
RTD/PT-100 Sensor,
(Thermocouple with Using Silicon Oil
& Without Bath(50 to 250°C)
THERMAL- Controller/ Indicator) With SPRT with
195 50 °C to 250 °C 0.27°C
TEMPERATURE Data Logger, Temp. Precision
Recorder, Temp. Temperature
Switch, Temp. Scanner
Gauge, Digital
Thermometer,
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 43 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Site Facility
ELECTRO-
TECHNICAL-
Using 6½ Digit
Alternating AC Current @ 50 Hz
1 Precision Multimeter 100 µA to 400 mA 0.120 % to 0.126 %
Current (< 1 & 1 kHz
by Direct Method
GHz)
(Measure)
ELECTRO-
TECHNICAL-
Using 6½ Digit
Alternating AC Current @ 50 Hz
2 Precision Multimeter 400 mA to 10 A 0.126 % to 0.136 %
Current (< 1 & 1 kHz
by Direct Method
GHz)
(Measure)
ELECTRO-
TECHNICAL-
Using AC/DC HV
Alternating AC High Voltage @
3 Probe with DMM By 1 kV to 15 kV 1.68%
Current (< 1 50 Hz
Direct Method
GHz)
(Measure)
ELECTRO-
TECHNICAL-
Using 6½ Digit
Alternating AC Voltage @ 50 Hz
4 Precision Multimeter 1 mV to 100 mV 1.3 % to 0.076 %
Current (< 1 & 1 kHz
by Direct Method
GHz)
(Measure)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 44 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
TECHNICAL-
Using 6½ Digit
Alternating AC Voltage @ 50 Hz
5 Precision Multimeter 1 V to 1000 V 0.070 % to 0.074 %
Current (< 1 & 1 kHz
by Direct Method
GHz)
(Measure)
ELECTRO-
TECHNICAL-
Using 6½ Digit
Alternating AC Voltage @ 50 Hz
6 Precision Multimeter 100 mV to 1 V 0.076 % to 0.070 %
Current (< 1 & 1 kHz
by Direct Method
GHz)
(Measure)
ELECTRO-
TECHNICAL-
Using 6½ Digit
Alternating
7 Capacitance DC Precision Multimeter 0.5 nF to 100 nF 3.854 % to 1.32 %
Current (< 1
by Direct Method
GHz)
(Measure)
ELECTRO-
TECHNICAL-
Using 6½ Digit
Alternating
8 Capacitance DC Precision Multimeter 100 µF to 10 mF 1.411 % to 1.17 %
Current (< 1
by Direct Method
GHz)
(Measure)
ELECTRO-
TECHNICAL-
Using 6½ Digit
Alternating
9 Capacitance DC Precision Multimeter 100 nF to 100 µF 1.32 % to 1.411 %
Current (< 1
by Direct Method
GHz)
(Measure)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 45 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 46 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
Using Multi Product
TECHNICAL-
AC Voltage @ 50 Hz Calibrator Fluke
16 Alternating 3.3 V to 1000 V 0.039 % to 0.059 %
& 1 kHz 5502E by Direct
Current (< 1
Method
GHz) (Source)
ELECTRO-
Using Multi Product
TECHNICAL-
AC Voltage @ 50 Hz Calibrator Fluke
17 Alternating 329.9 mV to 3.3 V 0.116 % to 0.039 %
& 1 kHz 5502E by Direct
Current (< 1
Method
GHz) (Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Capacitance @ 1 Calibrator Fluke
18 Alternating 0.5 nF to 329 nF 0.597 % to 0.293 %
kHz 5502E by Direct
Current (< 1
Method
GHz) (Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Capacitance @ 1 Calibrator Fluke
19 Alternating 329 nF to 110 µF 0.293 % to 0.657 %
kHz 5502E by Direct
Current (< 1
Method
GHz) (Source)
ELECTRO-
TECHNICAL- Using Decade
20 Alternating Inductance @ 1 kHz Inductance Box by 100 µH to 1 H 0.653 % to 0.98 %
Current (< 1 Direct Method
GHz) (Source)
ELECTRO-
TECHNICAL- Using 6½ Digit
21 DIRECT DC Current Precision Multimeter 10 µA to 100 µA 1.187 % to 0.072 %
CURRENT by Direct Method
(Measure)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 47 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
TECHNICAL- Using 6½ Digit
22 DIRECT DC Current Precision Multimeter 100 µA to 400 mA 0.072%
CURRENT by Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using 6½ Digit
23 DIRECT DC Current Precision Multimeter 400 mA to 10 A 0.072 % to 0.183 %
CURRENT by Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using HV Divider
24 DIRECT DC High Voltage Probe with DMM By 1 kV to 15 kV 4.3%
CURRENT Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using 6½ Digit
25 DIRECT DC Voltage Precision Multimeter 1 mV to 100 mV 0.685 % to 0.07 %
CURRENT by Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using 6½ Digit
26 DIRECT DC Voltage Precision Multimeter 1 V to 1000 V 0.071 % to 0.07 %
CURRENT by Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using 6½ Digit
27 DIRECT DC Voltage Precision Multimeter 100 mV to 1 V 0.07 % to 0.071 %
CURRENT by Direct Method
(Measure)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 48 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
TECHNICAL- Using 6½ Digit
28 DIRECT Resistance Precision Multimeter 0.1 Ohm to 100 Ohm 0.048 % to 0.4 %
CURRENT by Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using 6½ Digit
100 kOhm to 1000
29 DIRECT Resistance Precision Multimeter 0.013 % to 1.35 %
MOhm
CURRENT by Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using 6½ Digit
100 Ohm to 100
30 DIRECT Resistance Precision Multimeter 0.4 % to 0.013 %
kOhm
CURRENT by Direct Method
(Measure)
ELECTRO-
Using Multi Product
TECHNICAL-
Calibrator Fluke
31 DIRECT DC Current 1 µA to 329.9 µA 0.20 % to 0.018 %
5502E by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Calibrator Fluke
32 DIRECT DC Current 2.9 A to 10.9 A 0.05 % to 0.70 %
5502E by Direct
CURRENT
Method
(Source)
ELECTRO- Using Multi Product
TECHNICAL- Calibrator Fluke
33 DIRECT DC Current 5502E with 50T 20.0 A to 1000 A 0.92 % to 0.92 %
CURRENT Current Coil by
(Source) Direct Method
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 49 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
Using Multi Product
TECHNICAL-
Calibrator Fluke
34 DIRECT DC Current 329.9 mA to 2.9 A 0.013 % to 0.05 %
5502E by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Calibrator Fluke 329.9 µA to 329.9
35 DIRECT DC Current 0.018 % to 0.013 %
5502E by Direct mA
CURRENT
Method
(Source)
ELECTRO-
TECHNICAL- Using Low
36 DIRECT DC Resistance Resistance Jig by 1 k ohm 0.154%
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using Low
37 DIRECT DC Resistance Resistance Jig by 1 m ohm 2.119%
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using Low
38 DIRECT DC Resistance Resistance Jig by 1 ohm 0.15%
CURRENT Direct Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Calibrator Fluke 10 m Ohm to 329.9
39 DIRECT DC Resistance 6.123 % to 0.011 %
5502E by Direct Ohm
CURRENT
Method
(Source)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 50 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
TECHNICAL- Using Low
40 DIRECT DC Resistance Resistance Jig by 10 k ohm 0.154%
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using Low
41 DIRECT DC Resistance Resistance Jig by 10 m ohm 0.582%
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using Low
42 DIRECT DC Resistance Resistance Jig by 10 ohm 0.156%
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using Low
43 DIRECT DC Resistance Resistance Jig by 100 m ohm 2.313%
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using Low
44 DIRECT DC Resistance Resistance Jig by 100 ohm 0.154%
CURRENT Direct Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Calibrator Fluke 329.9 k ohm to 1100
45 DIRECT DC Resistance 0.014 % to 1.804 %
5502E by Direct M ohm
CURRENT
Method
(Source)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 51 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
Using Multi Product
TECHNICAL-
Calibrator Fluke 329.9 Ohm to 329.9
46 DIRECT DC Resistance 0.011 % to 0.015 %
5502E by Direct kOhm
CURRENT
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Calibrator Fluke
47 DIRECT DC Voltage 1 mV to 329.9 mV 0.062 % to 0.007 %
5502E by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Calibrator Fluke
48 DIRECT DC Voltage 3.3 mV to 1000 mV 0.006%
5502E by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Calibrator Fluke
49 DIRECT DC Voltage 329.9 mV to 3.3 V 0.007 % to 0.006 %
5502E by Direct
CURRENT
Method
(Source)
ELECTRO-
TECHNICAL- Using High
50 DIRECT High Resistance Resistance Jig by 1 G ohm 2.319%
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using High
51 DIRECT High Resistance Resistance Jig by 10 G ohm 2.361%
CURRENT Direct Method
(Source)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 52 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
TECHNICAL- Using High
52 DIRECT High Resistance Resistance Jig by 10 M ohm 2.36%
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using High
53 DIRECT High Resistance Resistance Jig by 100 G ohm 3.81%
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using High
54 DIRECT High Resistance Resistance Jig by 100 M ohm 2.312%
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using High
55 DIRECT High Resistance Resistance Jig by 1000 G ohm 5.519%
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using High
56 DIRECT High Resistance Resistance Jig by 200 M ohm 2.342%
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using High
57 DIRECT High Resistance Resistance Jig by 5 M ohm 5.94%
CURRENT Direct Method
(Source)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 53 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
TECHNICAL- Using High
58 DIRECT High Resistance Resistance Jig by 500 M ohm 2.316%
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using 6½ Digit
59 TEMPERATURE RTD (PT-100) Precision Multimeter -200 °C to 800 °C 0.04°C
SIMULATION by Direct Method
(Measure)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (B Calibrator Fluke
60 TEMPERATURE 600 °C to 1800 °C 0.177°C
Type) 5502E by Direct
SIMULATION
Method
(Measure)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (E Calibrator Fluke
61 TEMPERATURE -250 °C to 1000 °C 0.464°C
Type) 5502E by Direct
SIMULATION
Method
(Measure)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (J Calibrator Fluke
62 TEMPERATURE -200 °C to 1200 °C 0.12°C
Type) 5502E by Direct
SIMULATION
Method
(Measure)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (K Calibrator Fluke
63 TEMPERATURE -200 °C to 1370 °C 0.123°C
Type) 5502E by Direct
SIMULATION
Method
(Measure)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 54 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (N Calibrator Fluke
64 TEMPERATURE -200 °C to 1300 °C 0.131°C
Type) 5502E by Direct
SIMULATION
Method
(Measure)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (R Calibrator Fluke
65 TEMPERATURE 2 °C to 1760 °C 0.309°C
Type) 5502E by Direct
SIMULATION
Method
(Measure)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (S Calibrator Fluke
66 TEMPERATURE 2 °C to 1760 °C 0.283°C
Type) 5502E by Direct
SIMULATION
Method
(Measure)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (T Calibrator Fluke
67 TEMPERATURE -250 °C to 400 °C 0.166°C
Type) 5502E by Direct
SIMULATION
Method
(Measure)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (U Calibrator Fluke
68 TEMPERATURE -200 °C to 600 °C 0.123°C
Type) 5502E by Direct
SIMULATION
Method
(Measure)
ELECTRO-
Using Multi Product
TECHNICAL-
RTD (PT-100-385 Calibrator Fluke
69 TEMPERATURE -200 °C to 800 °C 0.041°C
Type) 5502E by Direct
SIMULATION
Method
(Source)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 55 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
Using Multi Product
TECHNICAL-
RTD (PT-1000-385 Calibrator Fluke
70 TEMPERATURE -200 °C to 630 °C 0.041°C
Type) 5502E by Direct
SIMULATION
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (B Calibrator Fluke
71 TEMPERATURE 600 °C to 1800 °C 0.16°C
Type) 5502E by Direct
SIMULATION
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (E Calibrator Fluke
72 TEMPERATURE -250 °C to 1000 °C 0.46°C
Type) 5502E by Direct
SIMULATION
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (J Calibrator Fluke
73 TEMPERATURE -200°C to 1200°C 0.12°C
Type) 5502E by Direct
SIMULATION
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (K Calibrator Fluke
74 TEMPERATURE -200 °C to 1370 °C 0.122°C
Type) 5502E by Direct
SIMULATION
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (N Calibrator Fluke
75 TEMPERATURE -200 °C to 1300 °C 0.13°C
Type) 5502E by Direct
SIMULATION
Method
(Source)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 56 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (R Calibrator Fluke
76 TEMPERATURE 2 °C to 1760 °C 0.309°C
Type) 5502E by Direct
SIMULATION
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (S Calibrator Fluke
77 TEMPERATURE 2 °C to 1760 °C 0.287°C
Type) 5502E by Direct
SIMULATION
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (T Calibrator Fluke
78 TEMPERATURE -250 °C to 400 °C 0.153°C
Type) 5502E by Direct
SIMULATION
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Thermocouple (U Calibrator Fluke
79 TEMPERATURE -200 °C to 600 °C 0.124°C
Type) 5502E by Direct
SIMULATION
Method
(Source)
ELECTRO-
TECHNICAL- Using 6½ Digit
80 TIME & Frequency Precision Multimeter 10 Hz to 100 kHz 0.012 % to 0.013 %
FREQUENCY by Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Time
Time Interval / Stop
81 TIME & Calibrator by Direct / 1 Sec to 10800 Sec 0.1 Sec to 4.88 Sec
Watch / Timer
FREQUENCY Comparison Method
(Measure)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 57 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
ELECTRO-
TECHNICAL- Using Time
Time Interval / Stop 10800 Sec to 86400 4.88 Sec to 36.891
82 TIME & Calibrator by Direct /
Watch / Timer Sec Sec
FREQUENCY Comparison Method
(Measure)
ELECTRO-
Using Multi Product
TECHNICAL-
Calibrator Fluke
83 TIME & Frequency 1 Hz to 500 kHz 10.2 % to 1.68 %
5502E by Direct
FREQUENCY
Method
(Source)
ELECTRO-
Using Multi Product
TECHNICAL-
Calibrator Fluke
84 TIME & Frequency 500 kHz to 2 MHz 1.68%
5502E by Direct
FREQUENCY
Method
(Source)
FLUID FLOW-
Liquid Media Analog "Using Ultrasonic
FLOW
85 & Digital Water Flow Meter by 1 m3/h to 230 m3/h 1.73
MEASURING
Flow, Rotameter Comparison Method"
DEVICES
Rotameter, Flow
FLUID FLOW- Using Air Flow
Mater, Gas Flow
FLOW Calibrator / Gas Flow
86 Meter, Dry Gas 0.5 LPM to 25 LPM 12.73 % to 2 %
MEASURING Analyzer by
Meter, Flow Rate
DEVICES Comparison method
Measuring Meters
Rotameter, Flow
FLUID FLOW- Using Air Flow
Mater, Gas Flow
FLOW Calibrator / Gas Flow
87 Meter, Dry Gas 25 LPM to 100 LPM 2.2%
MEASURING Analyzer by
Meter, Flow Rate
DEVICES Comparison method
Measuring Meters
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 58 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 59 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Non-Contact
Tachometer
Tachometer, RPM Stroboscope /
MECHANICAL-
Meter, Speedo Speedo Meter 10 rpm to 10000
93 ACCELERATION 0.36%
Meter, Centrifuge, /Stirrer / RPM Source rpm
AND SPEED
Contact Type / Vibrating M/c /
Abrasion Testing M/c
/ Centrifuge
Profile Projector/
MECHANICAL- Tool Makers
Using Standard Slip
DIMENSION Microscope / Optical
94 Gauge Block by 0 to 300 mm 7µm
(PRECISION Microscope, Linear
Comparison Method
INSTRUMENTS) X,Y Axis- L.C 0.001
mm
Profile Projector/
MECHANICAL-
Tool Makers Using Digital Caliper
DIMENSION
95 Microscope / Optical by Comparison 0 to 100 X 1.3%
(PRECISION
Microscope, Method
INSTRUMENTS)
Magnification
Profile Projector/
MECHANICAL-
Tool Makers Using Angle
DIMENSION
96 Microscope / Optical Graticule by 0 ° to 360 ° 2.2min
(PRECISION
Microscope, Angular Comparison Method
INSTRUMENTS)
L.C 1 min
MECHANICAL-
Using Electronic
DIMENSION up to 3000mm x 1.8 * [ (L+W)/125 ]
97 Surface Plate Level by Comparison
(PRECISION 3000 mm µmWhere L is in mm
Method
INSTRUMENTS)
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 60 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
MECHANICAL-
Video Measuring Using Slip Gauge Set
DIMENSION
98 Machine ( X , Y , Z & Long Slips by 0 to 300 mm 2µm
(PRECISION
Axis) L.C. : 0.1 µm Comparision method
INSTRUMENTS)
MECHANICAL-
Video Measuring
DIMENSION Using Glass Scale by
99 Machine ( X , Y , Z 0 to 300 mm 4.5µm
(PRECISION Comparision Method
Axis) L.C. : 0.1 µm
INSTRUMENTS)
MECHANICAL-
Video Measuring Using Angle
DIMENSION
100 Machine ( X , Y , Z Graticule by 0 ° to 360 ° 0.5min
(PRECISION
Axis) L.C. : 0.1 µm Comparision Method
INSTRUMENTS)
"VERIFICATION OF
MECHANICAL- Using Standard Test
ROCKWELL
HARDNESS blocks as per IS
101 HARDNESS TESTER HRA 1.6HRA
TESTING 1586- 2018-2018
BY INDIRECT
MACHINES (Part 1,2),
METHOD"
"VERIFICATION OF
MECHANICAL-
ROCKWELL "Using Standard
HARDNESS
102 HARDNESS TESTER Test blocks as per IS HRBW 1.6HRBW
TESTING
BY INDIRECT 1586-2018 (Part 1,2)
MACHINES
METHOD"
"VERIFICATION OF
MECHANICAL-
ROCKWELL "Using Standard
HARDNESS
103 HARDNESS TESTER Test blocks as per IS HRC 1.8HRC
TESTING
BY INDIRECT 1586-2018 (Part 1,2)
MACHINES
METHOD"
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 61 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Hydraulic Pressure
Digital & Dial
Pressure Gauge,
Pressure Using Automatic
MECHANICAL-
Transmitter, Pressure Calibrator
PRESSURE
104 Pressure Switch, By Comparison 0 to 20 bar 0.008bar
INDICATING
Pressure Calibrator method as per DKD
DEVICES
/Manometer R-6-1
/Pressure
Transmitter
Differential
Hydraulic-Pressure
Using Digital
Dial and Digital
MECHANICAL- Pressure Gauge and
Pressure Gauges,
PRESSURE Pressure
105 Pressure 0 to 1000 bar 0.8bar
INDICATING Comparator By
Transmitters,
DEVICES Comparison method
Pressure Switch,
as per DKD-R-6-1
Pressure Calibrator
Hydraulic-Pressure
Dial and Digital
MECHANICAL- Using Pressure
Pressure Gauges,
PRESSURE Calibrator By
106 Pressure 0 to 400 bar 0.098bar
INDICATING Comparision Method
Transmitters,
DEVICES as per DKD R-6-1
Pressure Switch,
Pressure Calibrator
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 62 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Hydraulic-Pressure
(Master Pressure
MECHANICAL- Using Pressure
Gauge, Pressure
PRESSURE Calibrator By
107 Calibrator, Pressure 0 to 700 bar 0.1bar
INDICATING Comparision Method
Transducer,
DEVICES as per DKD R-6-1
Pressure
Transmitter)
Pneumatic Pressure
Digital & Dial
Pressure Gauge,
MECHANICAL- Using Pressure
Pressure
PRESSURE Calibrator By
108 Transmitter, 0 to 35 bar 0.005bar
INDICATING Comparison method
Pressure Switch,
DEVICES as per DKD R-6-1
Pressure Calibrator,
Pressure Transmitter
Differential
Pneumatic Pressure
Digital & Dial
Pressure Gauge,
Using Digital
MECHANICAL- Pressure
Pressure Calibrator
PRESSURE Transmitter, -40 mbar to +40
109 By Comparison 0.1mbar
INDICATING Manometers, mbar
Method using DKD
DEVICES Magnehelic Gauge,
R-6-1 / 2
Pressure
Calibrator,Pressure
Switch
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 63 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Pneumatic Pressure
Digital & Dial
MECHANICAL- Using Pressure
Pressure Gauge,
PRESSURE Calibrator By
110 Pressure 0 to 7 bar 0.004bar
INDICATING Comparison method
Transmitter,
DEVICES as per DKD R-6-1
Pressure Switch,
Pressure Calibrator
Using Digital
MECHANICAL- Vacuum Dial / Digital Vacuum Indicator &
PRESSURE Gauges, Vacuum vacuum Comparator
111 -0.99 to 0 bar 0.008bar
INDICATING Calibrator & Vacuum By Comparison
DEVICES Transmitters Method as per DKD
R-6-1
MECHANICAL-
UTM, TENSION Using Load cell with
Uniaxial Testing
CREEP AND Indicator of Class 1
112 Machine 0.1 kN to 5 kN 2.0%
TORSION or better, IS
Compression mode
TESTING 1828:2015
MACHINE
MECHANICAL-
UTM, TENSION Using Load cell with
Uniaxial Testing
CREEP AND Indicator of Class 1
113 Machine, Tension 0.1 kN to 5 kN 2.0%
TORSION or better, IS
mode
TESTING 1828:2015
MACHINE
MECHANICAL-
UTM, TENSION Using Load cell with
Uniaxil Testing
CREEP AND Indicator of Class 1
114 Machine, 5 kN to 500 kN 2.0%
TORSION or better, IS
Compression mode
TESTING 1828:2015
MACHINE
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 64 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
MECHANICAL-
UTM, TENSION Uniaxil Testing Using Load cell with
CREEP AND Machine, Indicator of Class 1
115 200 kN to 1000 kN 2.0%
TORSION (UTM/CTM/TTM) in or better, IS
TESTING Compression mode 1828:2015 (Part-1)
MACHINE
MECHANICAL-
UTM, TENSION "Using Load cell with
Uniaxil Testing
CREEP AND Indicator of Class 1
116 Machine, Tension 5 kN to 500 kN 2.0%
TORSION or better, IS
mode
TESTING 1828:2015 (Part-1)
MACHINE
Using E1 & E2 Class
MECHANICAL-
Electronics Weighing weights. Weighing
WEIGHING
117 Balances Readability Balance of Class 2 100 mg to 1 kg 9mg
SCALE AND
: 0.001 g and Coarser as per
BALANCE
OIML R-76-1
Using F1 Class
MECHANICAL-
Electronics Weighing weights. Weighing
WEIGHING
118 Balances Readability Balance of Class III 1g to 20 kg 100 mg
SCALE AND
: 0.1 g and Coarser as per
BALANCE
OIML R-76-1
Using F2 Class
MECHANICAL-
Electronics Weighing weights up to 100kg.
WEIGHING
119 Balances Readability Weighing Balance of 100 g to 100 kg 10g
SCALE AND
: 10 g Class 3 and Coarser
BALANCE
as per OIML R-76-1
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 65 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Using F1 Class
MECHANICAL- weights up to 100
Electronics Weighing
WEIGHING kg. Weighing
120 Balances Readability 5g to 50 kg 2g
SCALE AND Balance of Class 3
:2g
BALANCE and Coarser as per
OIML R-76-1
Using M1 Class
MECHANICAL-
Electronics Weighing weights up to 300kg.
WEIGHING
121 Balances Readability Weighing Balance of 500g to 300 kg 50g
SCALE AND
: 50 g Class 3 and Coarser
BALANCE
as per OIML R-76-1
Using E1 & E2 Class
MECHANICAL-
Electronics Weighing weights. Weighing
WEIGHING
122 Balances Readability Balance of Class I 1 mg to 200 g 0.06mg
SCALE AND
:0.01 mg and Coarser as per
BALANCE
OIML R-76-1
Using E1 / E2 Class
MECHANICAL-
Electronics Weighing weights up to 200 g.
WEIGHING
123 Balances Readability Weighing Balance of 1mg g to 80 g 0.04mg
SCALE AND
0.01 mg Class I and Coarser
BALANCE
as per OIML R-76-1
Dial/Digital & Analog Using Humidity
THERMAL- Thermo-Hygrometer/ Chamber & Digital
124 SPECIFIC HEAT RH Sensors/ with RH & Temperature 15 %RH to 95 %RH 1.68%RH
& HUMIDITY indicator / Recorder/ indicator with
Data logger @25°C Sensor probe
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 66 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 67 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
"Temp. Transmitter,
Data Logger, Temp.
Calibrator Temp.
Using in Dry Block
Recorder, Temp.
THERMAL- Calibrator With S
129 Switch Temp. 600 °C to 1200 °C 2.64°C
TEMPERATURE Type Thermocouple
Gauge, Digital
and Read Unit
Thermometer Temp.
Controller/indicator
with Thermocouple"
"Temp. Transmitter,
Data Logger, Temp.
Calibrator Temp. Using in Dry Block
Recorder, Temp. Calibrator (50 to
THERMAL- Switch Temp. 650°C)With SPRT
130 250 °C to 600 °C 0.84°C
TEMPERATURE Gauge, Digital with Precision
Thermometer Temp. Temperature
Controller/indicator Scanner
with RTD &
Thermocouple"
"Temp. Transmitter,
RTD/PT-100 Sensor
(Thermocouple with
& Without Using Low
Controller/Indicator) Temperature Bath
THERMAL- Data Logger, Temp. With SPRT And
131 -30 °C to 50 °C 0.4°C
TEMPERATURE Calibrator Temp. Precision
Recorder, Temp. Temperature
Switch, Temp. Scanner
Gauge, Digital
Thermometer & Dry-
Wet Thermome
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 68 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Multi Position
Calibration With
Deep Freezers, using data Logger
THERMAL-
132 Refrigerator, Cold with RTD/T- -80°C to 50°C 1.75°C
TEMPERATURE
Room Thermocouple
Sensors / Wireless
datalogger:
Environmental
Chamber, Store
Multi Position
Room, Environment
Calibration With
controlling Room,
using data Logger
THERMAL- Oven, Incubator,
133 with RTD/T- 50 °C to 400 °C 1.75°C
TEMPERATURE BOD Incubator, ETO
Thermocouple
Sterilizer, Sterilizer,
Sensors / Wirless
Autoclave, Salt
datalogger
Spray Chamber,
HPLC
Humidity Chamber/ Multi Position
THERMAL- Salt Spray Chamber Calibration With
134 15 °C to 50 °C 2.46°C
TEMPERATURE / Environmental Using Wireless Data
Chamber/Incubator loggers
Multi Position
Oven, Dry Block, Calibration With
THERMAL-
135 Furnace, Tunnel, using data Logger 400 °C to 1200 °C 6.94°C
TEMPERATURE
Industrial Furnace with N Type
Thermocouple
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 69 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Temp. Indicator/
Controller of Liquid
Single Position
bath, Dry Block,
Calibration at
Freezers,
Measuring Location
Refrigerator,
THERMAL- in IUC With SPRT
136 Incubator, BOD -80 °C to 50 °C 0.45°C
TEMPERATURE and Read Unit
Incubator, Cold
Precision
Room, Chamber,
Temperature
Environmental
Scanner
Chamber, Salt Spray
Chamber,
Temp. Indicator/
Controller of Liquid
bath, Oven, Dry Single Position
Block, Furnace, Calibration SPRT
THERMAL-
137 Autoclave, with Precision 50 °C to 600 °C 0.26°C
TEMPERATURE
Incubator, Chamber, Temperature
Environmental Scanner
Chamber, Salt Spray
Chamber
Temp. Transmitter,
RTD/PT-100 Sensor,
(Thermocouple with Using Silicon Oil
& Without Bath(50 to 250°C)
THERMAL- Controller/ Indicator) With SPRT with
138 50 °C to 250 °C 0.27°C
TEMPERATURE Data Logger, Temp. Precision
Recorder, Temp. Temperature
Switch, Temp. Scanner
Gauge, Digital
Thermometer,
This is annexure to 'Certificate of Accreditation' and does not require any signature.
MATRIX LAB, 209 TO 210 2ND FLOOR B WING M CUBE, VAPI, VALSAD, GUJARAT,
Laboratory Name :
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-2664 Page No 70 of 70
Validity 12/01/2021 to 11/01/2023 Last Amended on -
Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument
Single Position
Temperature
Calibration at
Indicator/ Controller
THERMAL- Measuring Location
139 of Oven, Dry Block, 600 °C to 1200 °C 1.83°C
TEMPERATURE in IUC with S Type
Furnace, Melting
with Precision
Point App.
Tempreture Scanner
* CMCs represent expanded uncertainties expressed at approximately the 95% level of confidence, using a coverage factor of k = 2.
This is annexure to 'Certificate of Accreditation' and does not require any signature.