The document provides details of 38 procurement items including their descriptions, units of measurement, quantities, and bidder rates. The items include slope protection works using galvanized steel mesh, pavement works like subgrade preparation and laying of gravel, primer, tack coat and asphalt, bioengineering works like planting hedges, trees and grass, and street lighting works involving LED lights and related installation. The document appears to provide a bid for various civil works and supplies for a road project.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
127 views18 pages
5-22 (Bridge BOQ)
The document provides details of 38 procurement items including their descriptions, units of measurement, quantities, and bidder rates. The items include slope protection works using galvanized steel mesh, pavement works like subgrade preparation and laying of gravel, primer, tack coat and asphalt, bioengineering works like planting hedges, trees and grass, and street lighting works involving LED lights and related installation. The document appears to provide a bid for various civil works and supplies for a road project.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 18
Procument Item Details
SL. Bidder's Rate Bidder's Rate (in Total Amount
Item Description Unit Quantity No (NPR) words) (NPR) Slope Protection Work: Surface protection works for excavated slope using Hot-dip Galvanized Prefabricated Welded Steel Mesh: Supply and installation of prefabricated flexible galvanized steel mesh of 100mm x 100mm aperture size, made from minimum 6mm dia. bars having minimum galvanization of 500 grams/sqm, welded in such a way that the welding joints of the mesh 25 shall have minimum interpenetration sqm 3874.0 of 8% of the total diameter of the welded bar and having 200mm overlap on vertical joints and horizontal panels jointed using the spiral ring of 4mm dia. including appropriate machine, manpower, tools, tackles, fuel, erosion control blakent, local seed with humus for vegetation/ hydroseeding all complete as per the drawing and detailed technical specification. Pavement work: Preparation of subgrade as mentioned in the drawing, 26 m2 176116.62 specification and directed by the Engineer. Pavement work: Supplying, providing, laying, spreading, watering, leveling, compacting and all complete for gravel sub-base over prepared 27 subgrade according to the designed m3 49904.32 camber including transportation all complete as mentioned in the drawing, specification and directed by Engineer. Pavement work: Supplying, providing, laying, spreading, watering, leveling, compacting and all complete for crusher run base material grading of 28 m3 29464.49 standard specification including transportation from source as mentioned in drawing, specification and directed by the Engineer. Pavement work: Providing, laying, transporting and all complete of 29 primer coat as mentioned in drawing, Lit. 153956.62 technical specification and directed by the Engineer. Pavement work: Providing, laying, transporting and all complete of tack 30 coat as mentioned in drawing, Lit. 204398.31 technical specification and directed by the Engineer. Pavement work: Providing, mixing, laying, compacting, transport and all complete Dense Bituminous Macadam 31 m3 19113.0 (DBM) pavement surface as mentioned in drawing, specification and directed by Engineer. Procument Item Details
SL. Bidder's Rate Bidder's Rate (in Total Amount
Item Description Unit Quantity No (NPR) words) (NPR) Pavement work: Providing, mixing, laying, compacting, transport and all complete of asphalt concrete 32 m3 7697.83 pavement as mentioned in drawing, specification and directed by Engineer. Bio-Engineering: Providing and planting of permanent hedges of ornamental plants not greater than 2m (center of median) and not greater than 1m (edge of median (both side) including digging of trenches, 60cm wide and 45cm deep, refilling the 33 excavated earth mixed with farmyard Rm 16620.0 manure, supplied at the rate of 4.65 cum per 100m and supplying and planting hedge plants at 30 cm apart all complete and maintenance of hedge for 5 years including all materials required as per instruction of Engineer & technical specification. Bio-Engineering: Providing and planting flowering plants and shrubs in central verge and providing & 34 maintenance of flowering plants and Rm 22160.0 shrubs in central verge for five years as per drawing, specification and directed by Engineer. Bio-Engineering: Providing and planting rooted grass slips on the slopes <45o including preparation of slips on site, a max of 5 cm depth with 35 metal rod or operation includes m2 79215.84 digging planting hole to hard-wood peg, depending on the nature of the soil and as per directed by Engineer and drawing and specification. Bio-Engineering: Planting containerized tree and shrub seedlings, including pitting, transplanting, composting and mulching, on slopes < 36 30o with pit size 30 cm diameter x No. 88576.59 depth mix Compost with soil and back fill into pit to 1/4 of the pit volume as per drawing, specification and directed by Engineer. Bio-Engineering: Providing and Planting of trees by the road side in 0.60 m diameter holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, 37 No. 1650.0 planting the saplings, backfilling the trench, watering, fixing the tree guard and maintaining the plants for five year as per drawing, specification and directed by the Engineer. Procument Item Details
SL. Bidder's Rate Bidder's Rate (in Total Amount
Item Description Unit Quantity No (NPR) words) (NPR) Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and Nepal Telecom all Complete as per instruction of Engineer, NEA specification, drawings. Supply of 180W +/- 10 % Top Maintainable LED Street Light luminaire with System efficacy of 110 lm/W. LED Street Light shall be made up of Die Cast aluminium housing suitable to mounted on 55-68 mm OD bracket arm. Luminaire shall have two separate compartments for LEDs and driver and both compartments should be hermitically sealed to achieve IP 66 ingress protection. Optical compartment shall be provided to withstand IK 07 impact rating, while control gear shall be provided with die cast aluminium cover for safety. LM 80-08 compliant, LEDs from reputed makes such as Nichia, Japan / Cree, USA / Lumiled USA / Citizen Japan / Osram Germany / Seoul Korea / Bridgelux USA should be provided. LEDs used in the product shall comply with EN 62471 for Photo- biological safety and certificate for the same from manufacturer shall be provided for Risk Group 2 maximum. 38 Luminaire manufacturer shall produce Nos. 469.0 certificate of association with LED manufacturer for minimum 5 year. LEDs used shall have maximum allowed junction temperature of 125 Deg C with actual operating junction temperature not more than 90 Deg C at an ambient temperature of 35 Deg C. The LENS used shall have optical grade PMMA-HT / Polycarbonate to provide street light distribution for Uniform lighting. LED optical lens should be properly fixed to MCPCB and should not be only fixed by glue. LED optical lens shall have temperature withstand capacity of greater than 85 Deg C and Transmissivity of more than 90%.The LED shall be compliant with LM80- 08 standard with Useful L70 life of 50000 Hrs. tested at maximum current and at 105 Deg C case temperature (Complete LM 80 test report for LED should be submitted for 10000 hrs. of testing). The LEDs used in Street Light should be MacAdam Step 5 standard Rated LED with CCT of 5700 K and CRI of Minimum 70. Maximum permissible driving current of LEDs are from 0.15A to 2A. Actual Driving Current of LEDs shall be less than 1000mA for life long reliability. LED Driver should be BIS Registered. Procument Item Details
SL. Bidder's Rate Bidder's Rate (in Total Amount
Item Description Unit Quantity No (NPR) words) (NPR) LED Driver shall be Isolated type, Constant Current topology driver in metal enclosure with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 4KV internal surge protection in both Common Mode and Differential Mode. LED Driver shall be potted type. Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. LED driver shall have output short circuit & over voltage withstanding protection inbuilt. Luminaire shall be external SPD of 10KV with minimum one TMOV mounted inside luminaire. Bidder shall submit necessary test reports as mentioned in the description Make: Wipro: LR06-102 series or equivalent Procument Item Details
SL. Bidder's Rate Bidder's Rate (in Total Amount
Item Description Unit Quantity No (NPR) words) (NPR) Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and Nepal Telecom all Complete as per instruction of Engineer, NEA specification, drawings. CCMS System Details:(Same make as light fixture WIPRO or equivalent); Smart Feeder Panel made up of single / double door CRCA Sheet Steel with Grey Powder Coating / Painting of minimum 22 SWG and with IP54 Protection with A) Switching Point Controller: This hardware consists of MCBs, Contactors and Fuses which protects system and operators in case of electrical malfunction, Switching point controller VA rating is designed for twice the lighting load requirement, SPC uses Class 1.0 Single or Three Phase energy meter, It should allow Manual override of the system with Isolator during maintenance and system faults. It should have single phase/ three phase energy meter, Street light Feeder pillar with CCMS Controller and Switching components, web based application and cloud server. System capabilities including Scheduling, Individual lamp dimming, fault notifications and report 39 generation in command CVS format. Nos. 15.0 B) Energy Meter: It compliance with the standard IS: 13779/1999 or IEC: 1036. CBIP Report-325 Complied. Voltage Rating should be 10- 60A, Class 1.0, Rated frequency 50Hz, Power factor 0.25 lag - Unity 0.5 lead, as per IS13779. The system monitors energy parameters and communicate it with CCMS unit to transmit it to server, Voltages each phase, Current each phase, PF each phase, Metering KWH cumulative, Metering KVAH, Number of operational light, Number of non-operational lights, Failure of contactor, Status of the incoming supply (power failure), High /low voltage, Overload on the phases. C) CCMS Controller: Power supply - 230VAC, Communication through GSM/GPRS or Wi-Fi. It Should supports Phase wise on /off switching by Schedule or by built in astronomical clock for ON/OFF/Dimming luminaires based on individual selection and Manual ON/OFF/Dimming of lights of a particular switching point or networked switching points from Central Control Station. Battery Backed RTC in built in side CCMS Controller. CCMS supports wireless Low Power RF 2.4 ZigBee Procument Item Details
SL. Bidder's Rate Bidder's Rate (in Total Amount
Item Description Unit Quantity No (NPR) words) (NPR) communication with maximum 100 nos. of individual node/Luminaire controller which can dim up/down the led lamp up to 500W. Network Fault Tolerance: self-forming and self- healing RF mesh network having Open Field Range: 200 m. internal storage Memory 256MB X NAND Flash. Optional - Ethernet. Inbuilt Micro SD card for data storage (Capacity up to 16GB). Alert message in pre-defined abnormal system conditions through SMS (5 numbers) and web based application through GSM/GPRS for: i) Phase-wise currents on crossing threshold values ii) Phase-wise voltages on crossing threshold values. iii) MCB trips, iv) Theft alerts, v) No output supply vi) Group failure of lights vii) No input/output supply. Serial Communication: RS485/RS232, CCMS Controller can be remotely configurable through server. Communication Protocol - Street Light Gateway supports RS485 MODBUS communication and HTTPS support for Wireless communication with server using SIM based GPRS Connection. Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and 40 Nos. 15.0 Nepal Telecom all Complete as per instruction of Engineer, NEA specification, drawings. SIM based GPRS Connection ( On clients scope) Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and Nepal Telecom all Complete as per instruction of Engineer, NEA 41 Nos. 469.0 specification, drawings. 11m Octagonal Pole: Top Dia. 90mm, Bottom Dia. 210mm Sheet, Thickness 4.5 mm, Base Plate Dimensions (L x B x T) 350X350X30, PCD (275mm), Foundation bolt M25mmX1000mmX4 Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and 42 Nos. 469.0 Nepal Telecom all Complete as per instruction of Engineer, NEA specification, drawings. single Arm bracket 2000mm Procument Item Details
SL. Bidder's Rate Bidder's Rate (in Total Amount
Item Description Unit Quantity No (NPR) words) (NPR) Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and 43 Nos. 469.0 Nepal Telecom all Complete as per instruction of Engineer, NEA specification, drawings. RCC Concrete foundation for pole Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and Nepal Telecom all Complete as per 44 Nos. 469.0 instruction of Engineer, NEA specification, drawings. Junction box of IP-65 Grade with 3 phase 100 A copper busbar and two nos. 16 Amp DP MCB of 15 KA( as an option) Procument Item Details
SL. Bidder's Rate Bidder's Rate (in Total Amount
Item Description Unit Quantity No (NPR) words) (NPR) Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and Nepal Telecom all Complete as per instruction of Engineer, NEA specification, drawings. TWO POLE STRUCTURE:Make:Hulas with C Class Heavy Duty. Supply, Installation, Testing & Commissioning of 2 pole structure for terminating 11 KV O.H. supply from NEA as per specifications and drawing. The two pole structure shall comprise of:-steel tubular two pole structure 11 mtrs high( 6" Dia) (as per NEA approved), in cement concrete foundation 1:1.5:3 (1 cement : 1.5 coarse sand : 3graded aggregate 40mm nominal size) including excavation and refilling etc. as required. The rate shall be inclusive of painting with 2 coats of aluminium paint (on red oxide). The portion of pole under the ground shall be provided with 2 coats of bituminous paint - 2 Nos.; Steel sections, channels angles, flats, clamps, GI nuts, bolts and required hardware etc of different sizes for 45 No. 3.0 cross arms( with 42 x 42 and 5 mm thick, bracings, supports etc. for pole GOD etc. including anticlimbing barbed wires (conforming to IS:278) having 4 points barbs spaced 75 ±12mm apart. All steel structure shall be given 2 coats of red oxide primer and 2 finishing coats of aluminium paint as required. - Lot; 11 KV class disc/pin/support insulators complete with clamps and fixing hard wares etc. complete as required ; 11 KV station class thyrite type lightening arrestors complete with mounting arrangement (on all phases) - 3 Nos.; Drop out - lock out (DOLO) fuse, gang operating device (Air Break Switch) with pad locking arrangement (operating rod to be supported properly), complete with operating handle and locking arrangement - 1 Set; GI stay set complete with 20mm dia 1.8 M long stay rod with 450 x 450 x 7.5 mm anchor plate with thimbles, stay clamps,8 mm dia GI stay wire, turn buckle (20mm x 600mm) strain insulator bow tightner in cement concrete 1:3:6 foundation as excavation and refilling - 2 Set Procument Item Details
SL. Bidder's Rate Bidder's Rate (in Total Amount
Item Description Unit Quantity No (NPR) words) (NPR) Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and Nepal Telecom all Complete as per 46 RM 3556.0 instruction of Engineer, NEA specification, drawings. H.T. Cabling: Make: Havells india or equivalent 3 C x 35 Sq.mm XLPE HT 11 KV AL cable Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and Nepal Telecom all Complete as per instruction of Engineer, NEA specification, drawings. H.T. Cabling: Make: Havells india or equivalent. Supply, installation of 11 mtrs high( 6" Dia) steel pole for HT Cable support including cable hanging 47 No. 178.0 support with all accessories (as per NEA approved), in cement concrete foundation 1:1.5:3 (1 cement : 1.5 coarse sand : 3graded aggregate 40mm nominal size) including excavation and refilling etc. as required. The rate shall be inclusive of painting with 2 coats of aluminium paint (on red oxide). The portion of pole under the ground shall be provided with 2 coats of bituminous paint - 2 Nos. Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and Nepal Telecom all Complete as per instruction of Engineer, NEA specification, drawings. End 48 set 3.0 Termination: Raychem or equivalent. Heat shrinkable cable jointing of 3 core x 50 sq.mm 11 KV volts grade XLPE insulated armoured cables with suitable cable termination using Raychem/ MECP kits including all accessories. Procument Item Details
SL. Bidder's Rate Bidder's Rate (in Total Amount
Item Description Unit Quantity No (NPR) words) (NPR) Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and Nepal Telecom all Complete as per instruction of Engineer, NEA specification, drawings. End Termination: Raychem or equivalent. Supply, installation, testing and commissioning of Maintenance Free 49 No. 16.0 compound earthing stations by means of 2 meter long, 50 mm dia intergrated with 100x32x6 mm terminals filled with earth enhancing coumpound in required quantity all complete with 300 x300 x450 mm masonry enclosure with pre cast cover. All earthing arrangements must comply with IS–3043.The resistivity should be below 3 ohm. Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and Nepal Telecom all Complete as per instruction of Engineer, NEA specification, drawings. End Termination: Raychem or equivalent. Supply and installation of distribution transformer 100 KVA three phase NEA approved ONAN type with no load ratio of 11000/433 volts with both low and high voltage windings of high purity electrolytic copper. The 50 No. 3.0 transformer shall be complete with rating and diagram plate, 2 Nos. earthing terminals, and high winding temperature indicator. The distribution transformer shall be On load tap changer with -15% and +5% tappings in step of 2.5% each step on HV side, 3 phase 50 Hz with standard accessories (NEEK/TMC/SCHNEIDER).The transformer is pad mounted type so the cost must include 1.5 mtr. high concrete foundation suitable for transformer installation. Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and Nepal Telecom all Complete as per 51 instruction of Engineer, NEA RM 14117.0 specification, drawings. End Termination: Raychem or equivalent Supply, installation of 110 mm dia. HDP Pipe of 6 kg pressure on both side of road for laying of power cable. Procument Item Details
SL. Bidder's Rate Bidder's Rate (in Total Amount
Item Description Unit Quantity No (NPR) words) (NPR) Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and Nepal Telecom all Complete as per instruction of Engineer, NEA specification, drawings. End 52 RM 14117.0 Termination: Raychem or equivalent Trench for 110 mm HDP Pipe laying . The cost must include HT wrapping tape and cable marker upto height of 1000 mm at 5 mtr spacing.The pipe must have 150 mm sand all around and then filling of digged material. Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and Nepal Telecom all Complete as per 53 instruction of Engineer, NEA RM 2812.0 specification, drawings. End Termination: Raychem or equivalent Supply, installation of 32 mm dia. HDP Pipe of 6 kg pressure on both side of road for laying of power cable Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and Nepal Telecom all Complete as per instruction of Engineer, NEA 54 RM 432.0 specification, drawings. End Termination: Raychem or equivalent Supply, insta;llation of hot dip galvanised ladder type cable tray of size 450x 60 mm with all support and accessories for cable laying in bridge Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and 55 Nepal Telecom all Complete as per RM 6561.0 instruction of Engineer, NEA specification, drawings. End Termination: Raychem or equivalent 3C x 2.5 mm2 cu. unarmoured cable Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and 56 Nepal Telecom all Complete as per RM 4805.0 instruction of Engineer, NEA specification, drawings. End Termination: Raychem or equivalent 4C x 10 mm2 cu. Armoured cable Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and 57 Nepal Telecom all Complete as per RM 9312.0 instruction of Engineer, NEA specification, drawings. End Termination: Raychem or equivalent 4C x 16 mm2 cu. Armoured cable Procument Item Details
SL. Bidder's Rate Bidder's Rate (in Total Amount
Item Description Unit Quantity No (NPR) words) (NPR) Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and 58 Nepal Telecom all Complete as per RM 85.0 instruction of Engineer, NEA specification, drawings. End Termination: Raychem or equivalent 4C x 70 mm2 cu. Armoured cable Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and Nepal Telecom all Complete as per instruction of Engineer, NEA specification, drawings. Construction 59 of brick masonry chamber of internal No. 469.0 size 450x450mm with 250mm thick brickwork in 1:4 cement mortar, 450x450mm concrete manhole cover with frame (heavy duty), cement plaster inside, height varies from 300 to 1000mm.The manhole must have drain out provision. Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and Nepal Telecom all Complete as per instruction of Engineer, NEA specification, drawings. Construction 60 of brick masonry chamber of internal No. 5.0 size 600x600mm with 250mm thick brickwork in 1:4 cement mortar, 450x450mm concrete manhole cover with frame (heavy duty), cement plaster inside, height varies from 300 to 1000mm.The manhole must have drain out provision. Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and Nepal Telecom all Complete as per instruction of Engineer, NEA specification, drawings. Panel-IP 65 floor mounted as per following details (SIEMENS/HAGER); Incomer:250 4 pole MCCB of 25 kA with complete features of microprocessor release unit , for short circuit, over current and 61 No. 3.0 earth fault protection with adjustable setting with following accessories : Under voltage protection; Over voltage protection; Instantanous Over Current protection; Auxiliary contacts required for under voltage, over voltage and necessary interlocking of breakers.; Reverse Power relay.; Busbar : (Heat shrinkable colored sleeve) 200 A TPN Copper; Outgoings:4 Nos 32 A 15 kA 2-P MCB, 6 Nos 32 A 25 kA 4-P MCCB Procument Item Details
SL. Bidder's Rate Bidder's Rate (in Total Amount
Item Description Unit Quantity No (NPR) words) (NPR) Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and Nepal Telecom all Complete as per instruction of Engineer, NEA 62 specification, drawings. Provide, Job 1.0 supply and install, testing & commissioning and approvel from NTC/NEA as specified in Appendix-2 of Employer's Requirements to perform complete work of Optical Fiber. Electric Work : Electric Work and Optical Fiber Work: Providing, installing, excavation, testing and connecting, approved by NEA and Nepal Telecom all Complete as per instruction of Engineer, NEA specification, drawings. Provide, supply and install, testing & commissioning and approvel from NEA as specified in Appendix-2 of 63 Job 1.0 Employer's Requirements to perform complete work of Rehabilitation and Reconstruction of Electric work (i.e. 11kv crossing, 132 kv crossing, electric tower etc and newly construction of underground crossing of proposed electric work as per NEA specification, drawings and instruction of Engineer and all complete with closed co-ordination of NEA) Road Furnitures: Providing and laying of hot applied thermoplastic compound on rough surface (similar to Asphalt concrete and rigid pavement) at least 2 mm thick including 64 m2 107655.0 reflectorizing glass beads as per DOR Traffic sign manual/ Specifications . The finished surface to be level, uniform and free from streaks and holes. [1504] Road Furnitures: Providing and fixing of retro- reflectorized warning, Regulatory and informatory sign as per specification clause 1501made of high intensity grade sheeting, fixed over aluminium sheeting, 1.5mm thick supported on a 50 mm internal dia 65 steel tube or mild steel angle iron post No. 145.0 75 mm X 40 mm x 6mm firmly fixed to the ground by means of properly designed foundation with M 10/40 grade cement concrete 30cm x 30cm x 30cm below groung level or as per drawings and Technical Specification. 80cm x 60cm rectangular [1501]. Procument Item Details
SL. Bidder's Rate Bidder's Rate (in Total Amount
Item Description Unit Quantity No (NPR) words) (NPR) Road Furnitures: Providing and fixing of retro- reflectorized warning, Regulatory and informatory sign as per specification clause 1501made of high intensity grade sheeting, fixed over aluminium sheeting, 1.5mm thick supported on a 50 mm internal dia 66 steel tube or mild steel angle iron post No. 42.0 75 mm X 40 mm x 6mm firmly fixed to the ground by means of properly designed foundation with M 10/40 grade cement concrete 30cm x 30cm x 30cm below groung level or as per drawings and Technical Specification. 90cm equilateral triangle [1501]. Road Furnitures: Providing and Fixing Reinforced cement concrete M 15 grade kilometer Post including 67 painting and printing as per Standard No. 10.0 Drawing-2070 and Technical Specifications. One kilometer post (precast) [1506] Road Furnitures: Providing and Fixing Reinforced cement concrete M 15 grade kilometer Post including 68 painting and printing as per Standard No. 4.0 Drawing-2070 and Technical Specifications. Five kilometer Post (precast) [1506] Road Furnitures: 200 m Marker Stone: Providing and fixing of rosad stud100x100, die-cast in aluminium, resistant to corrosive effct of salt and grit, fitted with lenses reflectors, 69 installed in concrete or asphaltic No. 276.0 surface by drilling hole 30mm upto a depth of 60mm and bedded in a suitable bituminous grout or epoxy mortar, all complete as per drawing and Technical Specifications. [1505] Road Furnitures: Bridge Name Plate Sign (C29): Providing, fixing and erecting 50 mm dia steel pipe railing in 3 rows duly painted on medium 70 weight steel channels(ISMC series) No. 30.0 100 mm x 50 mm, 1.2 metres high aboveground, 2 m center to center, complete as per Drawing andTechnical specifications. [3105] Road Furnitures: Guard Rail: Providing and erecting "W" metal beam crashbarrier comprising of 3 mm thick corrugated sheet metal beam rail, 70cm above road/ground level, fixed on ISMC series channel vertical post, 71 150x75x5mm spaced 2m c/c, 1.8m rm 1635.0 high, 1.1m below ground/road level, metal beam rail to be fixed on the vertical post with a spacer of channel section 150x75x5mm, 330mm long complete as per drawing and technical specifications. [1509] Procument Item Details
SL. Bidder's Rate Bidder's Rate (in Total Amount
Item Description Unit Quantity No (NPR) words) (NPR) Road Furnitures: Road Delineators Post Providing and installation of 150 mm * 150 mm 1. 5 m long delineators (road way indicators, hazard 72 markers, object markers), 80-100 cm No. 420.0 high above ground level, painted black and white in 20 cm wide strips, buried or pressed into the ground and conforming to the drawings and Technical Specifications. [1507] Providing Insurance of Works, Plants, Equipments, Employers, Labors, Personal Injuries for the Employer's Design Work and Contractor's Design Work as per the conditions of contract, instruction of Engineer and all complete.The insurance shall cover all the works, goods, liability for breach of professional duty, injury to persons and damage to property, injury to 73 Job 1.0 employees, other insurance required by laws and by local practice and other requirement stipulated in the bid document complying with Beema Samiti's (Insurance Regulatery Authority of Nepal) guidelines, regulations, directives and other related document issued. The insurance premium shall not exeed 2.5% of the bid amount. Provide, supply and install Laboratory building including services, essential supplies like water, electricity, sanitary services and their maintenance and cost of all equipment, tools, materials, labour and 74 Month 27.0 incidentals as specified in Appendix-1 of Employer's Requirements to perform tests and other operations of quality control according to the specification and directed by Engineer. Providing and maintaining site office / Engineer’s site office including water supply, electricity, drainage, communication, security, 75 Month 27.0 accomodation and kitchen utilities and all the facilities as per employer’s requirement and conditions of contract. Prepare and submit monthly / Quarterly / Yearly / update of existing Environment Management Plan / 76 Month 27.0 progress report 6Nos. of copies each with soft copy and color prints in A4 size paper with color photo. Prepare and provide as built drawings in GIS base maps including report in 77 Set 1.0 4hard copies and 2CDs all complete set as per instruction of Engineer 3 Construction work Procument Item Details
SL. Bidder's Rate Bidder's Rate (in Total Amount
Item Description Unit Quantity No (NPR) words) (NPR) Contractors Design Works: Conduct detailed survey, geological, geo- physical and geo-technical investigation, hydrological investigation and preparation of detailed design and construction drawings for the Contractor’s Design 1 Works comprising 37 Nos. of Major LS 1.0 and Minor PSC Girder Bridges, Special PSC Box Bridges and associated works including design of expressway structures and slope stabilization work within bridge section as per the Employer’s Requirement. Contractors Design Works: Conduct detailed survey, geological, geo- physical and geo-technical investigation, hydrological investigation and preparation of detailed design and construction drawings for the Contractor’s Design 2 Works for Expressway, slope LS 1.0 stabilization works, service road (Dharan-Chatara Highway crossing at CH 47+110 of Main Lane of Expressway), retaining walls including RE wall and associated works as per the Employer’s Requirement. Contractors Design Works: Conduct detailed survey, geological, geo- physical and geo-technical investigation, hydrological investigation and preparation of detailed design and construction drawings for the Contractor’s Design 3 Works for Interchange at Budune, Toll LS 1.0 Plaza, service road & intersection at Dharan Chatara Highway connection (Phurkechaur) works and all complete as described in Employer's Requirement and associated works as per the Employer’s Requirement.From CH 43+800 to CH 44+800 Procument Item Details
SL. Bidder's Rate Bidder's Rate (in Total Amount
Item Description Unit Quantity No (NPR) words) (NPR) Contractors Design Works: Construction of foundations, sub- structures (Pier and Abutments), superstructures, protection works including slope stabilization work within bridge section; approach slab, approach road, river training works as specified in Employer’s Requirement, wing/return walls, Asphalt overlay, including utility works e.g. electrical and lighting works, optical fiber works, ; ancillary. for double lane twin bridges all complete as per the Employer’s Requirement and condition of contract for the Bridges and associated works as outlined below; (a) CH 41+054 to CH 41+144, 90 m length (Terai) (b) CH 41+046 to CH 41+106, 60m length (Kathmandu) (a) CH 41+229 to CH 41+539, 310m length (Terai)(b) CH 41+211 to CH 41+521, 310m length (Kathmandu)(a) CH 41+804 to CH 42+074, 270 m length (Terai)(b) CH 41+796 to CH 42+066, 270m length (Kathmandu).(a) CH 42+726 to CH 42+926, 200m length (Terai).(b) CH 42+734 to CH 42+934, 200 m length (Kathmandu). (a) CH 43+105 to CH 43+285, 180m length (Terai).(b) CH 43+115 to CH 43+295, 180 m length (Kathmandu). (a) CH 43+350 to CH 43+525, 175m 4 length (Terai).(b) CH 43+350 to CH LS 1.0 43+525, 175m length (Kathmandu).(a) CH 43+901 to CH 44+006, 105m length (Terai).(b) CH 43+899 to CH 44+004, 105m length (Kathmandu).(a) CH 44+410 to CH 44+445, 35m length (Terai).(b) CH 44+420 to CH 44+455, 35m length (Kathmandu).(a) CH 44+715 to CH 44+785, 70m length (Terai).(b) CH 44+735 to CH 44+805, 70m length (Kathmandu).(a) CH 45+544 to CH 45+694, 150m length (Terai).(b) CH 45+536 to CH 45+686, 150m length (Kathmandu).(a) CH 45+739 to CH 45+844, 105m length (Terai).(b) CH 45+756 to CH 45+816, 60m length (Kathmandu).(a) CH 46+124 to CH 46+229, 105m length (Terai).(b) CH 46+117 to CH 46+222, 105m length (Kathmandu).(a) CH 46+309 to CH 46+414, 105m length (Terai).(b) CH 46+311 to CH 46+391, 80m length (Kathmandu).(a) CH 46+574 to CH 46+774, 200m length (Terai).(b) CH 46+556 to CH 46+756, 200m length (Kathmandu).(a) CH 47+230 to CH 47+470, 240m length (Terai).(b) CH 47+228 to CH 47+468, 240m length (Kathmandu).(a) CH 47+841 to CH 48+021, 180m length (Terai).(b) CH 47+823 to CH 48+003, 180m length (Kathmandu).(a) CH 48+384 to CH 48+924, 540m Procument Item Details
SL. Bidder's Rate Bidder's Rate (in Total Amount
Item Description Unit Quantity No (NPR) words) (NPR) length (Terai).(b) CH 48+403 to CH 48+943, 540m length (Kathmandu).(a) CH 49+426 to CH 49+696, 270m length (Terai).(b) CH 49+431 to CH 49+701, 270m length (Kathmandu).(a) CH 00+288 to CH 00+328, 40m length. Note:*Width of each bridge is 11.8 m as per standard and as per the indicative drawings. The Bridge width may increase at the curved sections for extra widening as per road geometry. * Approach road means 20m extra road on each side of the longest twin bridge from the given chainage included in Contract’s Design Work Contractors Design Works: Construction of Expressway which includes earthwork works, slope stabilization works and /or valley side structures on one or both side of expressway (hill side and valley side) where ever required including slope preparation, reinforcement works horizontal drain, etc with facing 5 works, erosion control blanket with LS 1.0 hydro seeding as mentioned in specification and bio-engineering including retaining structures with proper water management and other associated works and all complete as per the Employer’s Requirement and instruction of Engineer as outlined below;From CH 41+164 to CH 41+191; Contractors Design Works: Construction of Expressway which includes earthwork works, slope stabilization works and /or valley side structures on one or both side of expressway (hill side and valley side) where ever required including slope preparation, reinforcement works horizontal drain, etc with facing 6 works, erosion control blanket with LS 1.0 hydro seeding as mentioned in specification and bio-engineering including retaining structures with proper water management and other associated works and all complete as per the Employer’s Requirement and instruction of Engineer as outlined below;From CH 41+560 to CH 41+760;