0% found this document useful (0 votes)
323 views6 pages

Steris Cmax Rev

Uploaded by

alamgirian
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
323 views6 pages

Steris Cmax Rev

Uploaded by

alamgirian
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

CMAX™

SURGICAL TABLE

Application
The Cmax Surgical Table is a mobile, electrohydraulically
operated surgical table designed to support all general
surgical procedures including cardiac and vascular,
endoscopic, gynecology, urology, nephrectomy,
neurology, ophtalmologic and orthopedics with the
addition of STERIS table accessories.

Description
The Cmax Surgical Table is a mobile, electrohydraulically
operated surgical table specifically designed to provide
the complete patient positioning flexibility required
for modern surgical care facilities. The Cmax Surgical
CP-STECMAX
Table features powered lateral tilt, trendelenburg/
reverse trendelenburg, Zip-Slide™ movable tabletop and The table accepts positioning commands from two sources:
adjustable height functions. STERIS Certified Pre-Owned
1. A hand control.
Equipment (CPO) refurbished Cmax Surgical Table has
2. A n Auxiliary Control System [physician-controlled foot
been refurbished to as-new condition, meeting esthetic
control (which includes Trendelenburg Tilts, Lateral
and operational standards of the original equipment
Tilts and Height functions)].
manufacturer (OEM). This table is designed to safely
NOTE: The Head Section is manually adjustable.
function with:
• 1100 lb (499 kg) without patient positioning or Overall size (W x L x H):
tabletop slide (except raise/lower) 22 x 81 x 26 to 45” (547 x 2055 x 675 to 1136 mm)
• 1000 lb (454 kg) full patient positioning (except Weight:
tabletop slide) 560 lb (250 kg)
• 600 lb (272 kg) full patient positioning (including
The standard table configuration includes:
tabletop slide)
• Power adjustable height, back, leg, Trendelenburg, Zip-
Table is constructed of aluminum alloy, stainless steel
Slide movable tabletop, radioluscent Kidney™ elevator
and other high quality materials. Table is equipped with
mechanism, flex/reflex and lateral tilt functions
a large sliding tabletop providing unrestricted radiological
• Manual, removable, head section
access without patient reversing.
• Pendant hand control
The Cmax Surgical Table is powered by either internal • Mobile base with hydraulically operated floor locks
battery or facility electric through use of the Intellipower ® • Up to three weeks operation (100-150 procedures) on
dual power system. internal battery power without recharging

The Selections Checked Below Apply To This Equipment


ACCESSORY PACKAGES
Standard Accessory Package
Item
Options
Location(s)
Foot Control

1
CMAX™
SURGICAL TABLE

FEATURES
Motorized tabletop is constructed of five-sections (including
the motorized fully radiolucent Kidney elevator mechanism)
and is 81” (2055 mm) long. Motorized Zip-Slide movable
tabletop eliminates the need for patient reorientation and
preconfiguration of the table. Unobstructed Imaging Length of
68” (1725 mm) and 100% C-Arm access without table movement
is available. For attaching accessories, the tabletop sections
include a standard stainless-steel side rail on both sides –
located where they will not obstruct the imaging area. Hook-
and-loop fastener strips on the tabletop sections permit instant
application and removal of the 2” (51 mm) thick, latexfree
mattress pad. The radiolucent tabletop sections enable viewing
of the entire anatomy (see illustration at bottom of this page).
Electrical System (the input electrical power) is fed by a
The easily attached X-Ray top design enables cassettes to be
detachable three-wire grounded power cord into an isolation
loaded from the head, foot, or either side for a full range of
transformer. The power is reduced to 24 V, and is rectified to dc.
exposure angles.
The operating system is powered by the 24 Vdc. Fuses are used
Column supports tabletop and includes lift cylinder, bearings, for protection of the system. The control operates on 24 Vdc.
hydraulic piping, hydraulic actuators for Trendelenburg, The hand control (an auxiliary CPU) and optional foot control
electrical wiring and master computer. These components are consist of switches that open or close to signal the computer in
enclosed by four telescoping stainless-steel column shrouds. the table column. The hand control includes feedback LEDs. If
The stainless-steel shrouds are of two-piece construction for ac main power fails, the battery system can be used to power
service accessibility. Hand Control and optional Foot Control the table. The Battery System is activated by ensuring the
connect at top of column. Main Power Switch on the front of the table base is ON and
Base structure is painted welded steel. The base cover is a depressing any button on the Hand Control. Activation of the
two-section, stainless-steel enclosure. Four large diameter Battery System permits the table to be articulated as necessary
swivel casters inside the base cover facilitate table relocation for approximately three weeks (without facility ac power) or
and movement. Four mechanical, hydraulically operated, between 100 and 150 procedures. The batteries are continuously
floorlocks are supplied. The power supply assembly and floor charging as long as the table is supplied with the appropriate ac
lock actuators are also within the base. Table power cord is voltage and the Main Power Switch is in the ON position.
plugged into a receptacle centered on the base head-end cover.
Auxiliary Control System controls are located beneath a cover
plate and stored in a convenient drawer (see illustration on page
5). Included are: SLIDE HEAD/FOOT, HEIGHT UP/DOWN, TREND./
REV. TREND., TILT RIGHT/LEFT, BACK UP/DOWN, LEG UP/DOWN,
KIDNEY UP/DOWN and LOCK/UNLOCK switch.

Electric controlled system provides powered tabletop


positioning. Hydraulic actuators perform all powered table
motions (except Zip-Slide movable tabletop which is powered
by an electric motor). The primary control system is a master
computer located in the table column. This computer selects
which outputs are to be actuated based on inputs from an
auxiliary CPU in the pendant hand control and/or optional foot
control. The hand control is a tethered pendant that hangs
from standard side rails. Hand control provides user inputs
(from touch pad switches via an auxiliary CPU) to the master
computer. It also includes status LEDs and tabletop position
indicators. An auxiliary control, located in the table base,
enables all table actuations.

3
CMAX™
SURGICAL TABLE

Pendant Hand Control is ergonomically designed, is Touch Pads include:


constructed of one-piece thermoformed plastic that holds and • FLEX/REFLEX
seals the keypad, is the primary interface for table operation, • SLIDE HEAD/FOOT
and the key pad is illuminated for easy table articulation • HEIGHT UP/DOWN
identification when room is dark. Hand Control is equipped with • TREND./REV. TREND.
a coiled 3’ (0.9 m), 12’ (3.7 m) extended, long cord. The Hand • TILT LEFT/RIGHT
Control plugs into a receptacle located at the top of the column. • BACK UP/DOWN
Membrane touch switches provide, through an auxiliary CPU, • LEG UP/DOWN
input signals to activate table functions and articulations. LED • KIDNEY UP/DOWN
indicators and LCD Display (see illustration above) provide the • LEVEL
following table operation information: • FLOOR LOCK (LOCK and UNLOCK)
• Auto Limit Sensors • OFF
• Battery Power NOTE: The LCD Display values are approximate. Their accuracy may
• Low Battery vary according to environmental conditions (e.g., altitude, humidity,
• Floor Lock Position temperature). Also, if a sensor is not operating properly, the value
• Maintenance Required indicated will be incorrect. Check patient positioning visually before
• Reverse Patient Orientation proceeding.
• Tabletop Positioning

4
CMAX™
SURGICAL TABLE

Auxiliary Control System can be actuated at any time and


allows table operation in the event of primary control or power
malfunction. The controls are located beneath a cover plate and
stored in a convenient drawer (see illustration). A pedal (foot
pump to provide hydraulic power) and Override Hand Control
(see illustration) comprise this system. Included functions on
Override Hand Control are: SLIDE HEAD/FOOT, HEIGHT UP/
DOWN, TREND./REV. TREND., TILT RIGHT/LEFT, BACK UP/DOWN,
LEG UP/ DOWN, KIDNEY UP/DOWN and LOCK/UNLOCK switch.

UNLOCK and SLIDE functions do not require foot pump


actuation. A green LED on the Override Hand Control indicates
the system is active.

TABLE OPERATION
Press the desired position touch pad on the pendant hand
control or optional foot control to position/articulate the Cmax
Surgical Table tabletop.

The following pre-operative actions must be completed before the


table can be used:

• Power activation: Use battery power or plug the table


power cord into the head of the table base and facility
power receptacle and toggle Main Power Switch to ON for
facility ac power.
• Turn the table on: Press any button on the hand control to
turn table ON. Hand control remains powered for 10 hours
from last button press.
• Lock the table: Press the FLOOR LOCK button on the Hand
Control and then the LOCK button to order the floor locks
Auto Limit Sensor™ control device (using the Intelligent Limit
into the “locked” position. Sensors) provides instant user feedback on conflicting tabletop
articulations when the table is positioned in standard
NOTE: Tabletop must be centered before floor locks may be “unlocked.”
configuration and how to resolve the conflict.

5
CMAX™
SURGICAL TABLE

TABLE MOTION 4. Cmax table accessories have specific weight claims/


capacities. Accessories may limit table patient weight
Refer to illustration on next page for the following ranges of
capacity.
table motion:
5. A patient grounding post/potential equalization terminal
• Flex/Reflex: 140°/90° (male connector, DIN 42801) is provided with the table. The
• Slide Motion: HEAD: 9” (227 mm) female connector for patient grounding is not furnished by
FOOT: 9” (227 mm) STERIS.
• Height Range: 26 to 45” (675 to 1136 mm) 6. WARNING – EXPLOSION HAZARD: Table must not be used in
• Trendelenburg Range: 30°±1° the presence of flammable anesthetics.
• Reverse Trendelenburg Range: 30°±1°
• Tilt Range: 20°±1°
• Back Section Motion: UP: 90°±1°
UTILITY REQUIREMENTS
DOWN: 40°±1°
• Leg Section Motion: UP: 0° Power Source:
DOWN: 105°±1° Battery/Electric-Powered Table
• Kidney Elevator Mechanism: 4” (110 mm) Line Power Input:
100/120/220/230-240 V ac (Jumper Selectable), 1 Ø, 50/60 Hz,
NOTES 4.0 Amp

1. Approximate Table Operating Weight: 560 lbs (250 kg). Environmental Conditions:
Temperature: 32-122°F (0-50°C)
2. Latex-free Pads are standard for this table.
Relative Humidity: 20-80% RH
3. Patient Weight Capacity:
CUSTOMER IS RESPONSIBLE FOR COMPLIANCE
• 1100 lb (499 kg) without patient positioning or
WITH APPLICABLE LOCAL AND NATIONAL CODES
tabletop slide (except raise/lower)
AND REGULATIONS.
• 1000 lb (454 kg) full patient positioning (except
tabletop slide)
The base language of this document is ENGLISH.
• 600 lb (272 kg) full patient positioning (including
Any translations must be made from the base
tabletop slide)
language document.