0% found this document useful (0 votes)
2K views

Resetting Service Hours ES4000 Basic

The document provides instructions for navigating and accessing different screens and menus on an Elektronikon Basic regulator. It details how to scroll through main screens, access data, programming, test and info menus. It also provides steps to call up and reset service timers and change service timer hours.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views

Resetting Service Hours ES4000 Basic

The document provides instructions for navigating and accessing different screens and menus on an Elektronikon Basic regulator. It details how to scroll through main screens, access data, programming, test and info menus. It also provides steps to call up and reset service timers and change service timer hours.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Instruction Elektronikon® Basic regulator

________________________________________________________________________________________________

1.8 Scrolling through all screens

From the Main screen press for 3s enter button (7) to enter in Menu and then you will find the following items:
• Data menu: Data counters parameters
• Programming menu: Submenu of regulation pressure, Timer, Display setting and Control setting.
• Test menu: Display test.
• Info menu: Information of firmware release.

Below the general overview of menu structure:

MENU
.
_____ <dAtA> Data menu
_____ <d.1> Calling up running hours
_____ <d.2> Calling up motor starts
_____ <d.3> Calling up module hours
_____ <d.4> Calling up loading hours
_____ <d.5> Calling up load solenoid valve
_____ <d.6> Calling up service timer
.
.
_____ <ProG> Programming menu
_____ <rEG.P> Regulation Pressure submenu
______ <Pr.SL> Calling up modifying pressure band selection
______ <LPr.1> Calling up modifying pressure band settings
______ <uPr.1> Calling up modifying pressure band settings
______ <LPr.2> Calling up modifying pressure band settings
______ <uPr.2> Calling up modifying pressure band settings
______ <nHCA> Calling up Number of hourly compressor activation
.
_____ <tiMr> Timer submenu
______ <SrV.d> Calling up Maintenance warning
.
_____ <diSP> Display submenu
______ <tEMP> Calling up modifying unit of temperature
______ <PrES> Calling up modifying unit of pressure
______ <bC.LG> Calling up modifying time of backlight
.
_____ <Ctrl> Control submenu
______ <Lo.rE> Calling up Local/remote start/stop
______ <Ar.Af> Calling up Automatic restart after voltage failure
______ <Ar.d> Calling up Delay Automatic restart after voltage failure
.
.
_____ <tEst> Test menu
_____ <tSt.1> Display testing
.
.
_____ <info> Info menu
_____ <P.rEL> Parameter Map Release
_____ <F.rRL> Firmware Release
_____ <F.dAY> Firmware Release Day
_____ <F.Mnt> Firmware Release Month
_____ <F.YAr> Firmware Release Year
_____ <SEr.n> Serial number

9 9828 0930 34 rev01


Instruction Elektronikon® Basic regulator
________________________________________________________________________________________________

This screen shows the number of unload to load actions (x 1 or - if <x1000> lights up - x 1000). In the above example, the
number of unload to load actions is 10100.

1.14 Calling up/resetting the service timer


Starting from the Main screen:
• Press Enter button (7) until enter in main menu.
• Select <dAtA> and press Enter button (7) for enter in data menu.
• Scroll up or down buttons (4-8) to <d.6> and running loaded hours is shown.
• Press Enter button (7): the loading time appears and are shown in <hrs>:
• Press and hold Enter Button (7) until <PASS> is shown.
• Scroll up or down to enter password 9989 then press Enter Button (7).
• Select <rES.Y> then press Enter Button (7)

This screen shows the unit used <hrs> (or <x1000 hrs>) and the value <1191>. In the example shown, the compressor has
run 1191 hours since the previous service.
For reset timer contact your dealer.

1.14.1 Changing Service timer hours


Starting from the Main screen:
• Press Enter button (7) until enter in main menu.
• Select <ProG> and press Enter button (7) to enter in data menu.
• Scroll up or down till <PASS> press Enter button (7)
• Scroll up or down to enter password 9989 then press Enter Button (7).
• Scroll up or down till <tiMr> press Enter button (7)
• <Sru.d> press Enter button (7) service hours timers hours are displayed
• Scroll up or down to adjust hours to desired level then press enter button (7)

12 9828 0930 34 rev01