Resetting Service Hours ES4000 Basic
Resetting Service Hours ES4000 Basic
________________________________________________________________________________________________
From the Main screen press for 3s enter button (7) to enter in Menu and then you will find the following items:
• Data menu: Data counters parameters
• Programming menu: Submenu of regulation pressure, Timer, Display setting and Control setting.
• Test menu: Display test.
• Info menu: Information of firmware release.
MENU
.
_____ <dAtA> Data menu
_____ <d.1> Calling up running hours
_____ <d.2> Calling up motor starts
_____ <d.3> Calling up module hours
_____ <d.4> Calling up loading hours
_____ <d.5> Calling up load solenoid valve
_____ <d.6> Calling up service timer
.
.
_____ <ProG> Programming menu
_____ <rEG.P> Regulation Pressure submenu
______ <Pr.SL> Calling up modifying pressure band selection
______ <LPr.1> Calling up modifying pressure band settings
______ <uPr.1> Calling up modifying pressure band settings
______ <LPr.2> Calling up modifying pressure band settings
______ <uPr.2> Calling up modifying pressure band settings
______ <nHCA> Calling up Number of hourly compressor activation
.
_____ <tiMr> Timer submenu
______ <SrV.d> Calling up Maintenance warning
.
_____ <diSP> Display submenu
______ <tEMP> Calling up modifying unit of temperature
______ <PrES> Calling up modifying unit of pressure
______ <bC.LG> Calling up modifying time of backlight
.
_____ <Ctrl> Control submenu
______ <Lo.rE> Calling up Local/remote start/stop
______ <Ar.Af> Calling up Automatic restart after voltage failure
______ <Ar.d> Calling up Delay Automatic restart after voltage failure
.
.
_____ <tEst> Test menu
_____ <tSt.1> Display testing
.
.
_____ <info> Info menu
_____ <P.rEL> Parameter Map Release
_____ <F.rRL> Firmware Release
_____ <F.dAY> Firmware Release Day
_____ <F.Mnt> Firmware Release Month
_____ <F.YAr> Firmware Release Year
_____ <SEr.n> Serial number
This screen shows the number of unload to load actions (x 1 or - if <x1000> lights up - x 1000). In the above example, the
number of unload to load actions is 10100.
This screen shows the unit used <hrs> (or <x1000 hrs>) and the value <1191>. In the example shown, the compressor has
run 1191 hours since the previous service.
For reset timer contact your dealer.