Catálogo Solar
Catálogo Solar
Solar Solutions
POWER ELECTRONICS CONTENTS
PE genetics Page. 4 — 7
Our secret
Page. 50 — 51
POWER ELECTRONICS OUR GENETICS
More than
GW
of installed
AC power
Solar + Storage
+
25
of annual
GW
production
capacity
+10k
solar inverters sold
+
30
years of
+ 25 excellence
1166 solar projects
#1 Manufacturer of solar International
inverters in America,
around the world Europe and Oceania. delegations
4 5
POWER ELECTRONICS OUR GENETICS
References
Our success
Freesun is the Power Electronics solar inverters range. Power around the world
Electronics has become the leading supplier of large-scale plant
installations in the United States, United Kingdom, Spain and Mexico,
and continues to expand worldwide.
Long-lasting
SOLAR INVERTERS
Designed for utility scale solar applications that require the advantages of a
central inverter combined with the modular design of string architecture.
Smart
6 7
POWER ELECTRONICS OUR PRODUCTS
INVERTER
8 9
POWER ELECTRONICS OUR PRODUCTS
These product
has the following
characteristics
HEMK
Offers the advantages of both central
and string inverters. The full front access
simplifies the maintenance tasks. 1 Easy maintenance
The advantages of a central inverter with
the modularity of the string inverters.
Bus Plus
2
Combine solar and storage.
The Bus Plus feature allows the connection of up
to four Freemaq DC/DC converters. It is the most
cost-competitive solution for solar-plus-storage
retrofits.
3Active heating
When the unit is not actively exporting power, the
inverter can import a small amount of power to keep
the inverter internal ambient temperature above -20°C,
without using external resistors.
10 11
POWER ELECTRONICS OUR PRODUCTS
5
Three-level
topology
The 3 level IGBT topology reduces stage losses,
increases inverter efficiency, and minimizes total
harmonic distortion. High efficiency to deliver
the lowest cost of energy (LCOE).
12 13
POWER ELECTRONICS OUR PRODUCTS
HEMK
King of compacts
STRING INVERTER
CABINETS
1500
Up to
6
different
AC voltages
4.39
Can reach up to a
nominal power of
MVA
DC CABINET AUXILIARY
PANEL
14 15
POWER ELECTRONICS OUR PRODUCTS
HEMK HEMK
REFERENCES
AC Output Power (kVA/kW) @40°C[1]
AC Output Power (kVA/kW) @50°C[1]
FRAME 2
FS2195K
2195
2035
690V FRAME 3
FS3290K
3290
3055
FRAME 4
FS4390K
4390
4075
REFERENCES
AC Output Power (kVA/kW) @40°C[1]
AC Output Power (kVA/kW) @50°C[1]
FRAME 2
FS2101K
2100
1950
660V FRAME 3
FS3151K
3150
2925
FRAME 4
FS4200K
4200
3900
Max. AC Output Current (A) @40°C 1837 2756 3674 Max. AC Output Current (A) @40°C 1837 2756 3674
OUTPUT Operating Grid Voltage (VAC) 690V ±10% OUTPUT Operating Grid Voltage (VAC) 660V ±10%
Operating Grid Frequency (Hz) 50/60Hz Operating Grid Frequency (Hz) 50/60Hz
Current Harmonic Distortion (THDi) < 3% per IEEE519 Current Harmonic Distortion (THDi) < 3% per IEEE519
Power Factor (cosine phi)[2] 0.5 leading … 0.5 lagging adjustable / Reactive power injection at night Power Factor (cosine phi)[2] 0.5 leading … 0.5 lagging adjustable / Reactive power injection at night
DC Voltage Range[3] 976V - 1500V DC Voltage Range[3] 934V - 1500V
Maximum DC Voltage 1500V Maximum DC Voltage 1500V
Number of Inputs Up to 40 Number of Inputs Up to 40
INPUT Max. DC Continuous Current (A)[4] 2295 3443 4590 INPUT Max. DC Continuous Current (A)[4] 2295 3443 4590
Max. DC Short Circuit Current (A)[4] 3470 5205 6940 Max. DC Short Circuit Current (A)[4] 3470 5205 6940
Number of MPPt (floating systems) 1 1 1, optionally 2 or 4 Number of MPPt (floating systems) 1 1 1, optionally 2 or 4
Number of Freemaq DC/DC [4] Up to 2 (Bus Plus Basic) or 4 (Bus Plus Advanced) Number of Freemaq DC/DC [4] Up to 2 (Bus Plus Basic) or 4 (Bus Plus Advanced)
Efficiency (Max) (η) 98.84% 98.87% 98.93% Efficiency (Max) (η) 98.81% 98.84% 98.90%
EFFICIENCY EFFICIENCY
Euroeta (η) 98.45% 98.48% 98.65% Euroeta (η) 98.45% 98.48% 98.65%
Dimensions [WxDxH] (ft) 9.8 x 6.6 x 7.2 Dimensions [WxDxH] (ft) 9.8 x 6.6 x 7.2
Dimensions [WxDxH] (m) 3.0 x 2.0 x 2.2 Dimensions [WxDxH] (m) 3.0 x 2.0 x 2.2
CABINET Weight (lbs) 11465 11795 12125 CABINET Weight (lbs) 11465 11795 12125
Weight (kg) 5200 5350 5500 Weight (kg) 5200 5350 5500
Type of Ventilation Forced air cooling Type of Ventilation Forced air cooling
Degree of Protection NEMA 3R / IP55 Degree of Protection NEMA 3R / IP55
Permissible Ambient Temperature -35°C to +60°C, >50°C / Active Power derating Permissible Ambient Temperature -35°C to +60°C, >50°C / Active Power derating
ENVIROMENT ENVIROMENT
Relative Humidity 4% to 100% non-condensing Relative Humidity 4% to 100% non-condensing
Max. Altitude (above sea level) 2000m / >2000m power derating (Max. 4000m) Max. Altitude (above sea level) 2000m / >2000m power derating (Max. 4000m)
Communication Protocol Modbus TCP Communication Protocol Modbus TCP
CONTROL INTERFACE Power Plant Controller Optional CONTROL INTERFACE Power Plant Controller Optional
Keyed ON/OFF Switch Standard Keyed ON/OFF Switch Standard
Ground Fault Protection GFDI and isolation monitoring device Ground Fault Protection GFDI and isolation monitoring device
Humidity Control Active heating Humidity Control Active heating
PROTECTIONS General AC Protection & Disconn. Circuit breaker PROTECTIONS General AC Protection & Disconn. Circuit breaker
General DC Protection & Disconn. Fuses, DC switch-disconnectors General DC Protection & Disconn. Fuses, DC switch-disconnectors
Overvoltage Protection Type 2 protection for AC and DC (optionally, Type 1+2) Overvoltage Protection Type 2 protection for AC and DC (optionally, Type 1+2)
Safety UL 1741 / CSA 22.2 No.107.1-16 / IEC 62109-1 / IEC 62109-2 Safety UL 1741 / CSA 22.2 No.107.1-16 / IEC 62109-1 / IEC 62109-2
CERTIFICATIONS CERTIFICATIONS
Installation NEC 2020 / IEC Installation NEC 2020 / IEC
& STANDARDS & STANDARDS
Utility Interconnect IEEE 1547:2018 / UL 1741 SB / IEC 62116:2014 Utility Interconnect IEEE 1547:2018 / UL 1741 SB / IEC 62116:2014
NOTES [1] Values at 1.00·Vac nom and cosφ=1. [4] Consult Power Electronics for Freemaq DC/DC connection NOTES [1] Values at 1.00·Vac nom and cosφ=1. [4] Consult Power Electronics for Freemaq DC/DC connection
Consult Power Electronics for derating curves. configurations (available for Frame 4). Consult Power Electronics for derating curves. configurations (available for Frame 4).
16 17
[2] Consult P-Q charts available: Q(kVAr)=√(S(kVA)2-P(kW)2). [5] Readings taken 1 meter from of the unit. [2] Consult P-Q charts available: Q(kVAr)=√(S(kVA)2-P(kW)2). [5] Readings taken 1 meter from of the unit.
[3] Consult Power Electronics for derating curves. [3] Consult Power Electronics for derating curves.
POWER ELECTRONICS OUR PRODUCTS
HEMK HEMK
REFERENCES
AC Output Power (kVA/kW) @40°C[1]
AC Output Power (kVA/kW) @50°C[1]
FRAME 2
FS2055K
2055
1905
645V FRAME 3
FS3080K
3080
2855
FRAME 4
FS4105K
4105
3810
REFERENCES
AC Output Power (kVA/kW) @40°C[1]
AC Output Power (kVA/kW) @50°C[1]
FRAME 2
FS2005K
2005
1860
630V FRAME 3
FS3005K
3005
2790
FRAME 4
FS4010K
4010
3720
Max. AC Output Current (A) @40°C 1837 2756 3674 Max. AC Output Current (A) @40°C 1837 2756 3674
OUTPUT Operating Grid Voltage (VAC) 645V ±10% OUTPUT Operating Grid Voltage (VAC) 630V ±10%
Operating Grid Frequency (Hz) 50/60Hz Operating Grid Frequency (Hz) 50/60Hz
Current Harmonic Distortion (THDi) < 3% per IEEE519 Current Harmonic Distortion (THDi) < 3% per IEEE519
Power Factor (cosine phi)[2] 0.5 leading … 0.5 lagging adjustable / Reactive power injection at night Power Factor (cosine phi)[2] 0.5 leading … 0.5 lagging adjustable / Reactive power injection at night
DC Voltage Range[3] 913V - 1500V DC Voltage Range[3] 891V - 1500V
Maximum DC Voltage 1500V Maximum DC Voltage 1500V
Number of Inputs Up to 40 Number of Inputs Up to 40
INPUT Max. DC Continuous Current (A)[4] 2295 3443 4590 INPUT Max. DC Continuous Current (A)[4] 2295 3443 4590
Max. DC Short Circuit Current (A)[4] 3470 5205 6940 Max. DC Short Circuit Current (A)[4] 3470 5205 6940
Number of MPPt (floating systems) 1 1 1, optionally 2 or 4 Number of MPPt (floating systems) 1 1 1, optionally 2 or 4
Number of Freemaq DC/DC [4] Up to 2 (Bus Plus Basic) or 4 (Bus Plus Advanced) Number of Freemaq DC/DC [4] Up to 2 (Bus Plus Basic) or 4 (Bus Plus Advanced)
Efficiency (Max) (η) 98.78% 98.81% 98.87% Efficiency (Max) (η) 98.76% 98.79% 98.85%
EFFICIENCY EFFICIENCY
Euroeta (η) 98.40% 98.43% 98.60% Euroeta (η) 98.39% 98.42% 98.59%
Dimensions [WxDxH] (ft) 9.8 x 6.6 x 7.2 Dimensions [WxDxH] (ft) 9.8 x 6.6 x 7.2
Dimensions [WxDxH] (m) 3.0 x 2.0 x 2.2 Dimensions [WxDxH] (m) 3.0 x 2.0 x 2.2
CABINET Weight (lbs) 11465 11795 12125 CABINET Weight (lbs) 11465 11795 12125
Weight (kg) 5200 5350 5500 Weight (kg) 5200 5350 5500
Type of Ventilation Forced air cooling Type of Ventilation Forced air cooling
Degree of Protection NEMA 3R / IP55 Degree of Protection NEMA 3R / IP55
Permissible Ambient Temperature -35°C to +60°C, >50°C / Active Power derating Permissible Ambient Temperature -35°C to +60°C, >50°C / Active Power derating
ENVIROMENT ENVIROMENT
Relative Humidity 4% to 100% non-condensing Relative Humidity 4% to 100% non-condensing
Max. Altitude (above sea level) 2000m / >2000m power derating (Max. 4000m) Max. Altitude (above sea level) 2000m / >2000m power derating (Max. 4000m)
Communication Protocol Modbus TCP Communication Protocol Modbus TCP
CONTROL INTERFACE Power Plant Controller Optional CONTROL INTERFACE Power Plant Controller Optional
Keyed ON/OFF Switch Standard Keyed ON/OFF Switch Standard
Ground Fault Protection GFDI and isolation monitoring device Ground Fault Protection GFDI and isolation monitoring device
Humidity Control Active heating Humidity Control Active heating
PROTECTIONS General AC Protection & Disconn. Circuit breaker PROTECTIONS General AC Protection & Disconn. Circuit breaker
General DC Protection & Disconn. Fuses, DC switch-disconnectors General DC Protection & Disconn. Fuses, DC switch-disconnectors
Overvoltage Protection Type 2 protection for AC and DC (optionally, Type 1+2) Overvoltage Protection Type 2 protection for AC and DC (optionally, Type 1+2)
Safety UL 1741 / CSA 22.2 No.107.1-16 / IEC 62109-1 / IEC 62109-2 Safety UL 1741 / CSA 22.2 No.107.1-16 / IEC 62109-1 / IEC 62109-2
CERTIFICATIONS CERTIFICATIONS
Installation NEC 2020 / IEC Installation NEC 2020 / IEC
& STANDARDS & STANDARDS
Utility Interconnect IEEE 1547:2018 / UL 1741 SB / IEC 62116:2014 Utility Interconnect IEEE 1547:2018 / UL 1741 SB / IEC 62116:2014
NOTES [1] Values at 1.00·Vac nom and cosφ=1. [4] Consult Power Electronics for Freemaq DC/DC connection NOTES [1] Values at 1.00·Vac nom and cosφ=1. [4] Consult Power Electronics for Freemaq DC/DC connection
Consult Power Electronics for derating curves. configurations (available for Frame 4). Consult Power Electronics for derating curves. configurations (available for Frame 4).
18 19
[2] Consult P-Q charts available: Q(kVAr)=√(S(kVA)2-P(kW)2). [5] Readings taken 1 meter from of the unit. [2] Consult P-Q charts available: Q(kVAr)=√(S(kVA)2-P(kW)2). [5] Readings taken 1 meter from of the unit.
[3] Consult Power Electronics for derating curves. [3] Consult Power Electronics for derating curves.
POWER ELECTRONICS OUR PRODUCTS
HEMK HEMK
REFERENCES
AC Output Power (kVA/kW) @40°C[1]
AC Output Power (kVA/kW) @50°C[1]
FRAME 2
FS2055K
1955
1815
615V FRAME 3
FS3080K
2935
2725
FRAME 4
FS4105K
3915
3635
REFERENCES
AC Output Power (kVA/kW) @40°C[1]
AC Output Power (kVA/kW) @50°C[1]
FRAME 2
FS2005K
1910
1775
600V FRAME 3
FS3005K
2865
2660
FRAME 4
FS4010K
3820
3545
Max. AC Output Current (A) @40°C 1837 2756 3674 Max. AC Output Current (A) @40°C 1837 2756 3674
OUTPUT Operating Grid Voltage (VAC) 615V ±10% OUTPUT Operating Grid Voltage (VAC) 600V ±10%
Operating Grid Frequency (Hz) 50/60Hz Operating Grid Frequency (Hz) 50/60Hz
Current Harmonic Distortion (THDi) < 3% per IEEE519 Current Harmonic Distortion (THDi) < 3% per IEEE519
Power Factor (cosine phi)[2] 0.5 leading … 0.5 lagging adjustable / Reactive power injection at night Power Factor (cosine phi)[2] 0.5 leading … 0.5 lagging adjustable / Reactive power injection at night
DC Voltage Range[3] 870V - 1500V DC Voltage Range[3] 849V - 1500V
Maximum DC Voltage 1500V Maximum DC Voltage 1500V
Number of Inputs Up to 40 Number of Inputs Up to 40
INPUT Max. DC Continuous Current (A)[4] 2295 3443 4590 INPUT Max. DC Continuous Current (A)[4] 2295 3443 4590
Max. DC Short Circuit Current (A)[4] 3470 5205 6940 Max. DC Short Circuit Current (A)[4] 3470 5205 6940
Number of MPPt (floating systems) 1 1 1, optionally 2 or 4 Number of MPPt (floating systems) 1 1 1, optionally 2 or 4
Number of Freemaq DC/DC [4] Up to 2 (Bus Plus Basic) or 4 (Bus Plus Advanced) Number of Freemaq DC/DC [4] Up to 2 (Bus Plus Basic) or 4 (Bus Plus Advanced)
Efficiency (Max) (η) 98.78% 98.81% 98.87% Efficiency (Max) (η) 98.76% 98.79% 98.85%
EFFICIENCY EFFICIENCY
Euroeta (η) 98.40% 98.43% 98.60% Euroeta (η) 98.39% 98.42% 98.59%
Dimensions [WxDxH] (ft) 9.8 x 6.6 x 7.2 Dimensions [WxDxH] (ft) 9.8 x 6.6 x 7.2
Dimensions [WxDxH] (m) 3.0 x 2.0 x 2.2 Dimensions [WxDxH] (m) 3.0 x 2.0 x 2.2
CABINET Weight (lbs) 11465 11795 12125 CABINET Weight (lbs) 11465 11795 12125
Weight (kg) 5200 5350 5500 Weight (kg) 5200 5350 5500
Type of Ventilation Forced air cooling Type of Ventilation Forced air cooling
Degree of Protection NEMA 3R / IP55 Degree of Protection NEMA 3R / IP55
Permissible Ambient Temperature -35°C to +60°C, >50°C / Active Power derating Permissible Ambient Temperature -35°C to +60°C, >50°C / Active Power derating
ENVIROMENT ENVIROMENT
Relative Humidity 4% to 100% non-condensing Relative Humidity 4% to 100% non-condensing
Max. Altitude (above sea level) 2000m / >2000m power derating (Max. 4000m) Max. Altitude (above sea level) 2000m / >2000m power derating (Max. 4000m)
Communication Protocol Modbus TCP Communication Protocol Modbus TCP
CONTROL INTERFACE Power Plant Controller Optional CONTROL INTERFACE Power Plant Controller Optional
Keyed ON/OFF Switch Standard Keyed ON/OFF Switch Standard
Ground Fault Protection GFDI and isolation monitoring device Ground Fault Protection GFDI and isolation monitoring device
Humidity Control Active heating Humidity Control Active heating
PROTECTIONS General AC Protection & Disconn. Circuit breaker PROTECTIONS General AC Protection & Disconn. Circuit breaker
General DC Protection & Disconn. Fuses, DC switch-disconnectors General DC Protection & Disconn. Fuses, DC switch-disconnectors
Overvoltage Protection Type 2 protection for AC and DC (optionally, Type 1+2) Overvoltage Protection Type 2 protection for AC and DC (optionally, Type 1+2)
Safety UL 1741 / CSA 22.2 No.107.1-16 / IEC 62109-1 / IEC 62109-2 Safety UL 1741 / CSA 22.2 No.107.1-16 / IEC 62109-1 / IEC 62109-2
CERTIFICATIONS CERTIFICATIONS
Installation NEC 2020 / IEC Installation NEC 2020 / IEC
& STANDARDS & STANDARDS
Utility Interconnect IEEE 1547:2018 / UL 1741 SB / IEC 62116:2014 Utility Interconnect IEEE 1547:2018 / UL 1741 SB / IEC 62116:2014
NOTES [1] Values at 1.00·Vac nom and cosφ=1. [4] Consult Power Electronics for Freemaq DC/DC connection NOTES [1] Values at 1.00·Vac nom and cosφ=1. [4] Consult Power Electronics for Freemaq DC/DC connection
Consult Power Electronics for derating curves. configurations (available for Frame 4). Consult Power Electronics for derating curves. configurations (available for Frame 4).
20 21
[2] Consult P-Q charts available: Q(kVAr)=√(S(kVA)2-P(kW)2). [5] Readings taken 1 meter from of the unit. [2] Consult P-Q charts available: Q(kVAr)=√(S(kVA)2-P(kW)2). [5] Readings taken 1 meter from of the unit.
[3] Consult Power Electronics for derating curves. [3] Consult Power Electronics for derating curves.
POWER ELECTRONICS OUR PRODUCTS
THE
AMERICAN
HEM
Page. 22 — 33
IDOL
22 23
POWER ELECTRONICS OUR PRODUCTS
These product
has the following
characteristics
HEM
The turn-key solution, simplifies the task
of designing the installation, and reduces
connection costs.
1 Easy maintenance
The advantages of a central inverter with
the modularity of the string inverters.
Bus Plus
2
Combine solar and storage.
The Bus Plus feature allows the connection of up to
four Freemaq DC/DC converters. It is the most cost-
3
competitive solution for solar-plus-storage retrofits.
ECON MODE
Remove no-load losses.
Disconnecting the power station from the grid
and, taking the medium-voltage transformer out
of the circuit, eliminating the continuous energy
cost of no-load losses.
Advanced grid
support 4
Capable of operating on any power system, offering
advanced grid support functionalities like fast
frequency response and synthetic inertia among
others.
24 25
POWER ELECTRONICS OUR PRODUCTS
5 iCOOL 3
The most innovative
cooling system.
Our own air ventilation system provides a constant
flow of clean air inside the equipment, without the
6
need of liquid cooling.
Active heating
When the unit is not actively exporting power, the
Patented inverter can import a small amount of power to keep
the inverter internal ambient temperature above -20°C,
without using external resistors.
7 Three-level
topology
The 3 level IGBT topology reduces stage losses,
increases inverter efficiency, and minimizes total
harmonic distortion. High efficiency to deliver
the lowest cost of energy (LCOE).
26 27
POWER ELECTRONICS OUR PRODUCTS
HEM
The ultimate
medium-voltage inverter
STRING INVERTER
CABINETS
1500 Vdc
Can reach up to a
4.2
nominal power of
DC-coupled
storage system
from 1200 kW to MVA
4800 kW
28 29
POWER ELECTRONICS OUR PRODUCTS
HEM HEM
REFERENCES FS4200M REFERENCES FS4105M
AC Output Power (kVA/kW) @40°C[1] 4200 AC Output Power (kVA/kW) @40°C[1] 4105
AC Output Power (kVA/kW) @50°C[1] 3900 AC Output Power (kVA/kW) @50°C[1] 3810
Operating Grid Voltage (kV)[2] 34.5kV ±10% Operating Grid Voltage (kV)[2] 34.5kV ±10%
OUTPUT OUTPUT
Operating Grid Frequency (Hz) 60Hz Operating Grid Frequency (Hz) 60Hz
Current Harmonic Distortion (THDi) < 3% per IEEE519 Current Harmonic Distortion (THDi) < 3% per IEEE519
Power Factor (cosine phi)[3] 0.5 leading … 0.5 lagging adjustable / Reactive power injection at night Power Factor (cosine phi)[3] 0.5 leading … 0.5 lagging adjustable / Reactive power injection at night
DC Voltage Range[4] 934V - 1500V DC Voltage Range[4] 913V - 1500V
Maximum DC Voltage 1500V Maximum DC Voltage 1500V
Number of Inputs Up to 40 Number of Inputs Up to 40
INPUT Max. DC Continuous Current (A)[5] 4590 INPUT Max. DC Continuous Current (A)[5] 4590
Max. DC Short Circuit Current (A) [5]
6940 Max. DC Short Circuit Current (A)[5] 6940
Number of MPPt (floating systems) 1, optionally 2 or 4 Number of MPPt (floating systems) 1, optionally 2 or 4
Number of Freemaq DC/DC[5] Up to 2 (Bus Plus Basic) or 4 (Bus Plus Advanced) Number of Freemaq DC/DC[5] Up to 2 (Bus Plus Basic) or 4 (Bus Plus Advanced)
Efficiency (Max) (η) 97.8% including MV transformer Efficiency (Max) (η) 97.76% including MV transformer
EFFICIENCY EFFICIENCY
Euroeta (η) 97.51% including MV transformer Euroeta (η) 97.50% including MV transformer
Dimensions [WxDxH] (ft) 21.3 x 6.5 x 7.2 Dimensions [WxDxH] (ft) 21.3 x 6.5 x 7.2
Dimensions [WxDxH] (m) 6.5 x 2.0 x 2.2 Dimensions [WxDxH] (m) 6.5 x 2.0 x 2.2
CABINET Weight (lbs) 30865 CABINET Weight (lbs) 30865
Weight (kg) 14000 Weight (kg) 14000
Type of Ventilation Forced air cooling Type of Ventilation Forced air cooling
Degree of Protection NEMA 3R Degree of Protection NEMA 3R
Permissible Ambient Temperature -35°C to +60°C, >50°C / Active power derating Permissible Ambient Temperature -35°C to +60°C, >50°C / Active power derating
ENVIROMENT ENVIROMENT
Relative Humidity 4% to 100% non-condensing Relative Humidity 4% to 100% non-condensing
Max. Altitude (above sea level)[6] 2000m Max. Altitude (above sea level)[6] 2000m
Communication Protocol Modbus TCP Communication Protocol Modbus TCP
CONTROL INTERFACE Power Plant Controller Optional CONTROL INTERFACE Power Plant Controller Optional
Keyed ON/OFF Switch Standard Keyed ON/OFF Switch Standard
Ground Fault Protection GFDI and isolation monitoring device Ground Fault Protection GFDI and isolation monitoring device
Humidity Control Active heating Humidity Control Active heating
PROTECTIONS General AC Protection & Disconn. MV switchgear (20 or 25 kA) PROTECTIONS General AC Protection & Disconn. MV switchgear (20 or 25 kA)
General DC Protection & Disconn. Fuses, DC switch-disconnectors General DC Protection & Disconn. Fuses, DC switch-disconnectors
Overvoltage Protection Type 2 protection for AC and DC (optionally, Type 1+2 for DC side) Overvoltage Protection Type 2 protection for AC and DC (optionally, Type 1+2 for DC side)
Safety UL 1741 / CSA 22.2 No.107.1-16 Safety UL 1741 / CSA 22.2 No.107.1-16
CERTIFICATIONS & STANDARDS Installation NEC 2020 CERTIFICATIONS & STANDARDS Installation NEC 2020
Utility Interconnect IEEE 1547:2018 / UL 1741 SB Utility Interconnect IEEE 1547:2018 / UL 1741 SB
[4] Consult Power Electronics for derating curves. [4] Consult Power Electronics for derating curves.
NOTES [1] Values at 1.00·Vac nom and cosφ=1. [5] Consult Power Electronics for Freemaq DC/DC connection NOTES [1] Values at 1.00·Vac nom and cosφ=1. [5] Consult Power Electronics for Freemaq DC/DC connection
Consult Power Electronics for derating curves. configurations. Consult Power Electronics for derating curves. configurations.
[2] Consult Power Electronics for other configurations.
30 [3] Consult P-Q charts available: Q(kVAr)=√(S(kVA)2-P(kW)2).
[6] Consult Power Electronics for altitudes above 1000m.
[7] Readings taken 1 meter from of the unit.
[2] Consult Power Electronics for other configurations.
[3] Consult P-Q charts available: Q(kVAr)=√(S(kVA)2-P(kW)2).
[6] Consult Power Electronics for altitudes above 1000m.
[7] Readings taken 1 meter from of the unit. 31
POWER ELECTRONICS OUR PRODUCTS
HEM
REFERENCES FS4010M
AC Output Power (kVA/kW) @40°C[1] 4010
AC Output Power (kVA/kW) @50°C[1] 3720
Operating Grid Voltage (kV)[2] 34.5kV ±10%
OUTPUT
Operating Grid Frequency (Hz) 60Hz
Current Harmonic Distortion (THDi) < 3% per IEEE519
Power Factor (cosine phi)[3] 0.5 leading … 0.5 lagging adjustable / Reactive power injection at night
DC Voltage Range[4] 891V - 1500V
Maximum DC Voltage 1500V
Number of Inputs Up to 40
INPUT Max. DC Continuous Current (A)[5] 4590
Max. DC Short Circuit Current (A)[5] 6940
Number of MPPt (floating systems) 1, optionally 2 or 4
Number of Freemaq DC/DC[5] Up to 2 (Bus Plus Basic) or 4 (Bus Plus Advanced)
Efficiency (Max) (η) 97.75% including MV transformer
EFFICIENCY
Euroeta (η) 97.48% including MV transformer
Dimensions [WxDxH] (ft) 21.3 x 6.5 x 7.2
Dimensions [WxDxH] (m) 6.5 x 2.0 x 2.2
CABINET Weight (lbs) 30865
Weight (kg) 14000
Type of Ventilation Forced air cooling
Degree of Protection NEMA 3R
Permissible Ambient Temperature -35°C to +60°C, >50°C / Active power derating
ENVIROMENT
Relative Humidity 4% to 100% non-condensing
Max. Altitude (above sea level)[6] 2000m
Communication Protocol Modbus TCP
CONTROL INTERFACE Power Plant Controller Optional
Keyed ON/OFF Switch Standard
Ground Fault Protection GFDI and isolation monitoring device
Humidity Control Active heating
PROTECTIONS General AC Protection & Disconn. MV switchgear (20 or 25 kA)
General DC Protection & Disconn. Fuses, DC switch-disconnectors
Overvoltage Protection Type 2 protection for AC and DC (optionally, Type 1+2 for DC side)
Safety UL 1741 / CSA 22.2 No.107.1-16
CERTIFICATIONS & STANDARDS Installation NEC 2020
Utility Interconnect IEEE 1547:2018 / UL 1741 SB
MEDIUM
MV SKID
VOLTAGE
Page. 38 — 39
STATIONS
Page. 40 — 41
TWIN SKID
34 35
POWER ELECTRONICS OUR PRODUCTS
Turn-key solution
MV Skid The SKID family facilitates the project design
and reduces the installation costs.
MV Simplify your
commissioning
STATIONS
All the medium voltage equipment is already integrated.
36 37
POWER ELECTRONICS OUR PRODUCTS
MV Skid
Compact
Easy to transport anywhere.
6.6 34.5
kV to kV
in the high voltage range
voltage range
Power outputs
from 1910 kVA
38 to 4390 kVA 39
POWER ELECTRONICS OUR PRODUCTS
Twin
Twin Skid
Compact
For the largest solar plants.
Extra high power density.
6.6 34.5
kV to kV
in the high voltage range
600 V - 690 V
in the low
voltage range
Choose the distribution
that fits better on you
solar plant
Power outputs
from 3820 kVA
to 8780 kVA
40 41
POWER ELECTRONICS OUR PRODUCTS
NOTES [1] Consult with Power Electronics for other options. NOTES [1] Consult with Power Electronics for other options.
[2] For lower temperatures, consult with Power Electronics. [2] For lower temperatures, consult with Power Electronics.
42 43
POWER ELECTRONICS OUR PRODUCTS
Page. 46 — 47
PPC PRO
EMS
EVERYTHING
Page. 48 — 49
IN VIEW
ADVANCED
CONTROL
SOLUTIONS
44 45
POWER ELECTRONICS OUR PRODUCTS
PPC PRO
The Power Plant Controller is the interface The governor
between the grid operator and the
inverters, made to fulfill the requirements
of every grid. Regardless of where you are. Smart Q distribution
This algorithm allows to distribute the
reactive power between the inverters
depending on the available active power,
maximizing the energy production.
46 47
POWER ELECTRONICS OUR PRODUCTS
24/7
Information
48 49
POWER ELECTRONICS OUR
OUR
PRODUCTS
SECRET
Before commissioning
1. We find the best solution for your requeriments.
2. We offer you made-to-measure trainings.
3. We help you in the most adapted applications.
During commissioning
We will always be at your side. We guarantee all your
equipment is correctly installed and functional.
After commissioning
We guarantee support 24/7, 365 days a year.
50 51
POWER ELECTRONICS CONTACT
WARRANTY HEADQUARTERS
Power Electronics (the Seller) warrants that their SPAIN UNITED STATES
Products are free of faults and defects for a period of 3 Polígono Pla de Carrases 1510 N. Hobson Street, Gilbert
years, valid from the date of delivery to the Buyer. It shall CV-35 Exit 30, 46160 Arizona, USA
be understood that a product is free of faults and defects Lliria - Valencia - Spain Tel. 602-354-4890
when its condition and performance is in compliance with Tel. (+34) 96 136 65 57 [email protected]
its specification. Fax (+34) 96 131 82 01 24/7 Technical Assistance Service
24/7 Technical Assistance Service
The warranty shall not extend to any Products whose Tel. (+34) 902 40 20 70
defects are due to (i) careless or improper use, (ii) failure
to observe the Seller’s instructions regarding the transport,
installation, functioning, maintenance and the storage of INTERNATIONAL
the Products, (iii) repairs or modifications made by the
Buyer or third party without prior written authorization of
the Seller, (iv) negligence during the implementation of ARGENTINA FRANCE PERU
authorized repairs or modifications, (v) if serial numbers are Arroyo 894, 5º 51 Rue Hoche, 94200 Ivry Sur Seine. Avenida El Polo nº 670, Centro Comercial
modified or illegible, (vi) anomalies caused by, or connected Oficina 10 Ciudad autónoma de Paris (France) El Polo II – Oficina 603, Piso 6º, Bloque C
to, the elements coupled directly by the Buyer or by the final Buenos Aires +33(0)1 46 46 10 34 Santiago de Surco, Lima
customer, (vii) accidents or events that place the Product [email protected] (+51) 979 749 772
outside its storage and operational specification, viii) ASIA Contact: Guillaume Mamy [email protected]
continued use of the Products after identification of a fault 30th Floor, CATIC Plaza, 8 Cau- Contact: Gustavo Prialé
or defect. seway Road, Hong Kong SAR INDIA
Silver Jade, Off. No 03, G.F., A-Wing CTS NO. GERMANY
The warranty excludes components that must be replaced AUSTRALIA -188, Behind Tarun Bharat Society, Chakala, Deieselstrasse, 77. D-90441.
periodically such as Fuses + DC switch, lamps & air filters U6, 30-34 Octal St. Yatala, Brisbane, Andheri East, Mumbai, Maharashtra Nürnberg. Germany
or consumable materials subject to normal wear and tear. Queensland 4118, Australia (+91) 80 6569 0489 [email protected]
(+61) 7 3386 1993 [email protected]
The warranty excludes external parts that are not [email protected] SOUTH AFRICA
manufactured by the Seller under the brand of Power ITALIA Central Office Park Unit 5
Electronics. BEIJING Piazzale Cadorna, 6, 20123.
257 Jean Avenue – Centurion 0157
Xiaoying Road Chaoyang, Nº25, [email protected]
Milán Italia
The Seller undertakes to replace or to repair, himself, at Beijing City [email protected]
their discretion, any Product or its part that demonstrates UNITED KINGDOM
a fault or defect, which is in conformance with the BRAZIL JAPAN Chippenham Drive, Unit 2, Madingley Court.
aforementioned terms of the warranty. Reasonable costs Avda. Robert Kennedy 2070. Sao Bernardo do Nishi-Shinbasi 2-17-2 HF Toranomon Bldg 5F. Kingston, Milton Keynes.
associated with the disassembly/ assembly, transport and Campo. Sao Paulo 105-0003 Minato-Ku Tokio MK10 0BZ, United Kingdom
customs of equipment will also be undertaken by the Seller (+55) 11 5891 9612 / (+55) 11 5891 9762 [email protected] [email protected]
except in cases of approved intervention by the Buyer and/ [email protected] Contact: Stanley Han Contact (Solar division): Juan Antonio Torres
or their representative where cost allocation has been Contact: Fabio Cinquini
previously agreed. MALAYSIA PHILIPPINES
Unit 209 ZF Page 1 Bldg MBP
CHILE Level 7, Menara Milenium, Jalan Damanlela,
Pusat Bandar Damansara, Damansara Ayala Alabang, Muntinlupa.
Av. Alonso de Córdova 5870, Of. 210-211
DUBAI
Power Electronics reserves the right to modify whole or part of the content of this P.O. Box 487282, 33rd Floor,
brochure at any time and without prior notice. May 2021.
HDS Business Centre Jumeirah
Lakes Towers, Dubai, U.A.E