Configurable Multi Input Multi Set Point
Configurable Multi Input Multi Set Point
ASCON spa
GENERAL INDEX
SERIAL COMMUNICATIONS
(see the instruction manual “SERIAL COMMUNICATION
SUPPLEMENT” supplied separately)
2
1 • IDENTIFICATION OF MODEL
XP - A B C D
Power supply A
100 …240 V 50/60 Hz 3
16 …28 V 50/60 Hz and 20…30 Vdc 5
Serial communications
275.8
B 275.8
None 0 4 50
20mA C.L. Std Ascon protocol 1
20mA C.L. Modbus/Jbus protocol 2
OPTIONS
Retransmission output Y4 C
None 0
Fitted (4...20 mA or 0...10 Vdc) 1
Set point D
Standard
(up to 4 mem. or Loc./Rem.) 0
Time-programmable 1
(11 segments)
1
1 • IDENTIFICATION OF MODEL
Model code
Input X E
275.8
275.8
1st part
F 4 50
Main output Y1 5
H
OPZIONI
Auxiliary output Y2 I
part
Auxiliary output Y3 L
2nd
Retransmission output Y4 M
Set point W N
2
2 • FUNCTION OF KEYS AND DISPLAYS
275.8
Program holden 15
Active Remote Set 11
2 Set point (W)
275.8
Active serial communication 13 10 Manual operation
Memorized programme in
execution 14 3 Servomotor position
5 Main output Y1 increases
4 50
Auxiliary window N° 4 7a servomotor position when
"ON"
6
7b Main output Y1F (cool)
decreases servomotor
Auxiliary output Y3 “ON” 9 position when 'ON"
Auxiliary output Y2 “ON” 8 16 Edit Set point
18 Increment digit
Functions (menu) 19
17 Select digit
Face seal IP54
20 Confirm data
Withdrawal screw 21 Automatic/Manual
Front cover
NUMERIC INDICATORS X, W, Y, N°
1 - Process The value of measure X is expressed in engineering
variable (X) (green) units.
If above end of scale 8888
____
If below beginning of scale 8888
----
10
275.8 - In programmation: displays parameter values
- In configuration: displays the values of the 1st part
of the configuration code (see enclosed leaflet)
4
in which case led 5 “W” lights up too
7.5 b - the N° of the segment in execution (option with
4 4
programmable set, see chapter 11)
a b in this case, led 6 “SG” lights up too
3
2 • FUNCTION OF KEYS AND DISPLAYS
Loop -
275.8 With output Y3 active and configured as Loop
Break Alarm, the front displays X and W are
Break - 275.8
flashing (see p. 13)
Alarm 4 50
4
2 • FUNCTION OF KEYS AND DISPLAYS
KEYS
16 - Edit Set Point Standard configuration:
(1 Local + 4 storable used for:
• modifying the Set point
• recalling the 4 memorized Set points
(see enclosed leaflet)
Remote Set configuration:
(1 Local + 1 Remote) used for:
• passing from Local to Remote Set point
and viceversa (see enclosed leaflet)
Programmed Set configuration:
(see chapter 11)
• to recall the Local operating Set point
• to start, stop, start again the
execution of the memorized programme
5
3 • DIMENSIONS - INSTALLATION
96
W - +
F A/M
110
min.
Front cover Ring with hook
projection and locking screw +0.8
92
Advised +0.6
thickness 1 ÷ 16 45
Wiring protection plate Panel apertures
Holding
hooks
AMBIENT
Temperature: 0 ÷ 50°C Locking
! Humidity : 30 ... 85uR%
Seal ring fitting screws
275.8
if different from
°C, remove and
4 50
°F Pa
% kPa
HR% MPa
mV l/m
V m3/h
mA Nm3/h
A CO%
kW O2%
psi m
! Do NOT force
cross-screwdriver labels supplied
Bar rh
6
4 • ELECTRICAL WIRING
Wiring
protection plate
2
Rotate
downwards
Plate screw
Cold joint
compensation 3 gilded
thermometer terminals for
input signals
2
6.9 max.
With fork
terminals 1
Rotate
1 7
upwards
0.25 ÷ 2.5
6.9 max. AWG
22 ÷ 14
2
Depress the plate to
engage the pin
With tinned wire
2
6÷7
Preferential
7
4 • ELECTRICAL WIRING
Serial communication A
Analogic inputs B
Logic inputs and analogic A B C A B C
signals C
Channel for low level signal conductors
Input D
Outputs E
Wiring diagram
1 COM 11
TX 21 Single power supply
9 100…240Vac - 50/60 Hz 1
Serial 2 IL1 12
communication 4 22
(optional) Logic
3 inputs IL2 13
RX 23 Y3
4 IL3 14 Auxiliary
24 Y2 outputs 7
3
Remote set input 5 15
0%
25
X 4…20 mA
6 + 24 Vdc 16
(2)
5 26 Y1 Relay increase
i 17 Main
A 100% output
2 wire 7 27 Y1 Relay decrease
transmitter 8 18 6
Input
B Retransmission
28
process
variable (X) 9 output Y4 19
B
(option) 29
2 mA J, L, 10 20
Volt K, S… Pt100
(1)
8
4 • ELECTRICAL WIRING
Schema
1 • Singledipower
collegamento
supply
"Switching" type
11 • Standard: 100 to 240 Vac - 15% + 10%
Single power supply • for low tension: 24 Vac -15% + 10%
12 24 Vdc ±15%
Absorbed power 4VA
7 7 7
X
Rin
Rin
Rin
9 9 9
Rin = 30 Ω per mA Transmitter
Rin = 10 KΩ per Volt com.
9
4 • ELECTRICAL WIRING
Schema
3 • Remote
di collegamento
Set point input
Rin = 30 Ω per mA
Rin = 330 KΩ per V
In current 4..20 mA
In voltage 0..10Vdc
5
Remote Set point mA, Volt Rin NOT galvanically
25 ! isolated
4 • Logic inputs
External contacts COM
21 An impulsive (2 sec. at least)
H C1 closing of contacts C1, C2, C3,
IL1 permits the selection AUTO or MAN,
22
H C2 Local or Remote Set point, recalling
IL2
23 the 4 memorized Set points and
H C3 launching of the programmed Set
IL3
24 point. (see p. 14)
6 • Main output Y1
10
4 • ELECTRICAL WIRING
Retransmission:
of measurement X
of Set point W
11
5 • AUXILIARY OUTPUTS Y2 AND Y3
Deviation
On Active high Set point ∆W (1)
W1 Off (above) -300...+300 units
compared to W1
Active low
H (under)
∆W
Band
On Active Out Set point I ∆WI (1)
W1 Off -0...300 units
compared to W1
Active In
H H
I∆WI I∆WI
Independent
On Active high Set point (1):
W1 Off (above) from beginning
On to end of scale
Off Active low
H (under)
W
(1) The Set point of Y2 and Y3 is not limited by the limits of the main
Set point W1, but only by the scale span.
Deviation with startup inhibition
inhibition
∆W
W1
On
Off
Active high Set point ∆W (1)
Startup (above) -300...+300 units
compared to W1
W1
Active low
∆W
inhibition (below)
On
Off
Startup
12
5 • AUXILIARY OUTPUTS Y2 AND Y3
Gas
mA
h
°C
Time-programmable intervention
13
6 • PASSWORDS
WpAss
Enter password of access to configuration
(see enclosed leaflet)) 3333
NO
Return to normal
OK function
YES
Introduction into configuration
NO
Return to normal
OK function
YES
Introduction into the 5th group
14
9 • MODIFYING THE OPERATING STATE
Interface
No action
ON Passage from REMOTE to LOCAL
ON Passage from AUTOMATIC to MANUAL
ON ON Passage from MANUAL to AUTOMATIC
passage
ON Local Sp. to Remote Sp.
Local Sp. = Memorized Sp. 1 Programme startup RUN
Local Sp. = Memorized Sp. 2 __ Passage to successive
ON ON
segment (NEXT)
Local Sp. = Memorized Sp. 3 __ Temporary stop
ON ON of programme HLD
Local Sp. = Memorized Sp. 4 __ Restart after stop of
ON ON ON
programme
Note 1: Is possible to fix the selected Set point holding closed the relative contacts.
While they are closed is possible to make changment from Auto/Man or Man/Auto but
it is not possible to change Set point
15
12 • TECHNICAL DATA
1 Local + 4 storable
Set point
Distinct ascent and descent
(standard 0.1...120.0% scale/min. or step gradient
gradient slope
version)
Higher and lower limit from beginning to end of scale
Auto/Man With bumpless action, AUTO/MAN transfer via keyboard, logic input and serial
Station communication.
16
12 • TECHNICAL DATA
Hysteresis 0,1..10%
Auxiliary deviation ± 300 steps (with or without
outputs inhibited startup)
Y2 - Y3
Type of Set point band 0...300 steps
(configurable)
independent from beginning to end of scale
Loop-Break-Alarm
(signal of control loop defect)
Special functions time-programmable
(only for Set programmable option)
Retransmission Current 4..20mA (450Ω max, 10Vdc max) galvanically
output Y4
isolated
(option) Voltage 0..10Vdc (500Ω min, 20mA max)
Serial
Interface 20mA C.L. passive and galvanically isolated
communication
For other data, see manual
(option)
On three levels for: modification, indication only,
Access to parameters
no access
Protections Immunity to disturbances level IV, standard IEC 801-4
All significant data are stored in a non-volatile memory
17
GUARANTEE
ASCON spa
20021 Bollate (Milano), Italy
Via Falzarego, 9/11 - Tel. (0039 - 2) 33337.1
Fax (0039 - 2) 3504243 - Telex 322451 ASCON I