Operating Instructions
WARNING!
Before use of SPIROMATIC S7 SCBA in an emergency/rescue situation, the user
must have been given proper training in its use, have read and understood these
Operating Instructions and demonstrated proficiency to a responsible teacher or
supervisor. Failure to do so can result in injury or death for the user and can have
serious consequences for people to be rescued and/or items of value to be saved.
INTERSPIRO’S LIMITED WARRANTY
INTERSPIRO warrants this product against failure to comply with INTERSPIRO’s published specifications for the
product and against defects in materials and workmanship for a period of twelve (12) months after date of purchase.
Within that period, INTERSPIRO will, at its option, repair or replace the product or refund your purchase price if
INTERSPIRO determines the product does not conform to INTERSPIRO’s specifications or is defective in material
or workmanship.
To make a warranty claim, contact your authorized INTERSPIRO distributor or INTERSPIRO directly. For
telephone inquiries please have your product invoice or other proof of purchase available. If you write, include
proof of purchase and a written explanation of the problem. Warranty servicing will be provided on-site or at one
of INTERSPIRO’s authorized service facilities, at INTERSPIRO’s discretion. If shipment to an authorized service
facility is required, shipping instructions will be provided by INTERSPIRO or your authorized INTERSPIRO
distributor. Do not ship any product or component without shipping authorization. All shipping charges to
INTERSPIRO’s service facility must be prepaid by the customer.
This limited warranty does not apply if the product has been (I) involved in an accident or subjected to misuse,
improper maintenance or negligence; (II) altered or repaired in any way that has, in INTERSPIRO’s judgement,
adversely affected its performance or reliability; (III) used in an application or for a purpose for which the product
was not designed or under stresses or conditions exceeding those specified for the product; or (IV) damaged after
leaving INTERSPIRO’s facility.
This limited warranty is valid only for the original purchaser, and is not transferable.
IMPORTANT! This limited warranty is exclusive and is in lieu of all other warranties, expressed or implied,
including any warranty of merchantability or fitness for a particular purpose. INTERSPIRO disclaims all
other liabilities and obligations, including, to the extent allowed by law, non-contractual liability for personal
injury or property damage based upon its negligence, strict liability or any other ground. To the full extent
allowed by law, and regardless of whether liability is asserted on the basis of breach or warranty, negligence,
strict liability, breach of contract or otherwise, INTERSPIRO shall not be responsible for special, incidental,
consequential or punitive damages, including loss of property, loss of profits or revenues, down-time costs
and the cost of substitute equipment (some states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation may not apply to you).
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
SPIROMATIC S7
CAUTIONS AND LIMITATIONS
D. Air-line respirators can be used only when the respirators are supplied with respirable air meeting the requirements of
CGA G-7.1 Grade D or higher quality.
E. Use only the pressure ranges and hose lengths specified in the user’s instructions.
I. Contains electrical parts which have not been evaluated as an ignition source in flammable or explosive atmosphere by
MSHA/NIOSH.
J. Failure to properly use and maintain this product could result in injury or death.
M. All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, OSHA, and other
applicable regulations.
N. Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as specified by the
manufacturer.
O. Refer to users instructions, and/or maintenance manuals for information on use and maintenance of these respirators.
S. Special or critical users instructions and/or specific use limitations apply. Refer to instruction manual before donning.
Contents
Important Information to User............................................................................. 5
1 Technical Description......................................................................................... 6
1.1 Harness Assembly 6
1.2 Air Supply 6
1.3 Face Mask 7
1.4 Breathing Valve and By-pass Valve 7
1.5 Regulator Assembly with RIC UAC 8
1.6 SpiroGuide Electronics Package Including BAC, HUD and DDU 8
1.7 Audible and Visual Low Air Warnings 9
1.8 Integrated PASS 9
1.9 Optional Cylinder Quick Coupling 10
1.10 Safety Certifications 10
2 Preparations for use......................................................................................... 11
2.1 Battery Installation / Replacement 11
2.2 BAC Battery Installation / Replacement 11
2.3 HUD Battery Installation / Replacement 11
2.4 Harness Adjustment 12
2.5 Mounting the Cylinder 12
2.6 Connecting the Face Mask 14
2.7 Linking the HUD 15
3 Understanding the S7 HUD, DDU and BAC....................................................... 16
3.1 Understanding the Heads-Up Display (HUD) 16
3.2 Understanding the Digital Display 17
3.3 Understanding the BAC 18
4 Leakage and function test............................................................................... 19
5 Donning.................................................................................................................... 21
6 During Use............................................................................................................... 23
6.1 PASS Sensing Mode 23
6.2 PASS Pre-alert 23
6.3 PASS Alarm 23
6.4 Low Air Warnings 23
6.5 Emergency Operation 24
6.6 Rapid Intervention Crew/Company Universal Air Connection System 24
6.7 Supplied Air Operations 25
6.8 Buddy Breathing 26
7 Telemetry Functions - Configuration Option........................................... 27
7.1 Installation of SpiroLink SCBA Telemetry Unit 27
7.2 Battery Installation / Replacement 28
7.3 Preparation for Use 29
7.4 During Use 29
8 Tracking Functions - Configuration Option............................................. 31
9 Doffing..................................................................................................................... 32
10 Cleaning and maintenance............................................................................... 33
10.1 Air Supply 33
10.2 Face Mask 33
10.3 Reassemble Apparatus 34
10.4 Cylinder Charging 34
10.5 Service and Testing 35
10.6 Replacement/Retirement Considerations 36
10.7 Storing the Apparatus 36
10.8 Marking Recommendations and Restrictions 36
11 SpiroGuide electronics configuration and PASS data logging......... 37
11.1 Default and Configuration Optional Settings for the BAC and DDU 37
11.2 Internal PASS Data Logging 37
Important Information to User
Please read this information carefully before referring to the apparatus instructions.
The SPIROMATIC S7 breathing apparatus should only be used by adults in good physical and physiological condition.
The SPIROMATIC S7 SCBA must be used in a manner consistent with NFPA 1500, Standard on Fire Department Occupational
Safety and Health Program.
The face mask may not seal properly with your face if you have a beard, heavy sideburns or other physical characteristics
interfering with the mask’s contour.
An improper facial seal may allow non-respirable air to leak into the mask, reducing or eliminating respiratory protection. The
seal must be tested before each use.
OSHA 1910.134 requires that before any employee uses a positive pressure tight-fitting facepiece, they must pass an appropriate
qualitative or quantitative fit test initially and at least annually thereafter.
Do not use SPIROMATIC S7 in an emergency/rescue situation unless you have received proper training in its use, have read and
understood this Instruction manual and demonstrated proficiency to a responsible teacher or supervisor. Special attention must
be given to:
- face seal
- test before use
- awareness of different durations at different conditions
- emergency situation (loss of air and free air flow)
- procedure at low-air alarm.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense. Operation is subject to the following two conditions: (1)
this device may not cause interference, and (2) this device must accept any interference, including interference that may cause
undesired operation of the device.
Only holders of a valid INTERSPIRO Service Certificate may service and test SPIROMATIC S7 apparatus.
Failure to comply with these special points can result in respiratory injury or death for the user and may have serious
consequences for people to be rescued and/or items of value to be saved.
1 Technical Description
The SPIROMATIC S7 is a compressed air breathing apparatus for work in a contaminated environment. The apparatus consists
of:
• A harness assembly
• An air supply cylinder
• A face mask with breathing valve and by-pass including:
-A wireless Heads-Up Display (HUD) inside the face mask
• A regulator unit including:
-A Breathing apparatus computer (BAC)
-A Digital Display Unit (DDU)
-A Rapid Intervention Crew/Company Universal Air Connection System (RIC UAC)
-An integrated Personal Alert Safety System (PASS)
-Optional tracking senders
-Optional telemetry unit
• An extra air/rescue hose connection
The SPIROMATIC S7 self contained breathing apparatus (SCBA) uses clean dry air compressed in a cylinder, carried on the
back. The air is fed to a pressure regulator which reduces the cylinder air pressure to a secondary pressure of approximately 110
psi. The air is then supplied to the face piece through the mask mounted breathing valve.
The breathing valve is of the pressure-demand type that releases air on inhalation. The SPIROMATIC S7 operates with positive
pressure which keeps toxic gases from leaking into the facepiece. Even if leakage was to occur, the positive pressure keeps
surrounding air out of the mask, although under such conditions duration of the air supply may decrease.
A primary audible low air warning device placed at the pressure gauge / DDU is located at the left shoulder in front of the
user. A wireless Heads-Up Display (HUD) installed inside the face mask acts as a visual pressure gauge and also provides a
secondary visual low air warning at both 1/2 and 1/4 cylinder pressure. The HUD allows both the cylinder pressure and the
visual low air warning to always be in the wearer’s field of vision. The HUD also includes a low battery indicator.
The apparatus is equipped with a Personal Alert Safety System (PASS) which is an integrated PASS unit designed to meet the
NFPA 1982 Standard on PASS for Fire Fighters 2007 Edition. The PASS unit is integrated into the SCBA and is automatically
activated by air pressure from the SCBA. Tracking system and telemetry system can be installed as an option.
Caution!
Should the cylinder be exposed to a pressure that causes the burst disc to rupture, it must be returned to an authorized
SPIROMATIC S service center for inspection and repair.
Duration* Charging pressure psi Approx. content of.
free air in cu. ft
60 min. 4500 87
45 min. 4500 66
30 min. 4500 45
30 min. 2216 45
* Duration tested to NIOSH standards.
Limitation!
Approved only when compressed air reservoir is fully charged with air meeting the requirements of the Compressed Gas
Association Specification G-7-1 for Type 1, Grade D air or higher quality, as well as meeting a dew point level of -65°F (-
54°C) or dryer (24 ppm v/v or less), and a maximum particulate level of 5 mg/m3 air. The container shall meet applicable
DOT specifications.
Caution!
Duration is dependent on the user’s exertion, physical and emotional condition, as well as on environmental pressure and
whether the cylinder was fully charged and whether the facepiece fits. DURATION CAN VARY 50 % OR MORE.
1.5 Regulator Assembly with RIC UAC
The pressure regulator used in the SPIROMATIC S7 models is a balanced piston pressure reducer with an extremely high flow
capacity. The very high capacity ensures that the positive pressure is maintained in the mask even at low cylinder pressures and
at extremely high breathing rates.
The regulator unit is of a “plug in” type which means that it is pushed into a manifold and locked in place with a locking clip
and cover. This modular system enables simple servicing to be carried out with minimum down time for the apparatus by using
service exchange of modular components.
The manifold assembly is comprised of a regulator manifold with a handwheel connector for the cylinder valve, a particle filter,
and a high pressure Rapid Intervention Crew/Company Universal Air Connection System (RIC UAC).
The RIC UAC will permit replenishing the breathing air cylinder of an SCBA user to be replenished from an independent rescue
breathing air supply source while the SCBA victim remains trapped or unable to be removed from the hazardous atmosphere.
The S7 is equipped with a supplied air connector that is conveniently placed on the right shoulder. This makes connection of air
line hoses and accessories easy for the user.
RIC UAC
DDU BAC connection
Manifold
assembly
The BAC is a computer unit and pressure sensor mounted in the backplate. It
is powered by 6 AA batteries.
The wireless HUD is a combination pressure gauge and electronic low air
warning device. It also indicates PASS Pre-Alert mode and PASS Alarm
mode. The HUD is installed in the face mask.
The BAC and HUD will link together based on an address code received
from each other. The BAC and HUD to be used together must linked before
use, following the procedure in section 2.7. When the BAC is started it will
only connect to the HUD it previously has been linked to.
The HUD includes a light sensor to measure the ambient light. The brightness
of the LEDs is automatically adjusted according to the ambient light
conditions. The pressure indication displayed in the HUD is refreshed every 2
seconds. The HUD is powered with 2 AAA batteries.
The DDU is located on the left shoulder with the mechanical pressure gauge
and mechanical whistle. The DDU is connected with a cable to the BAC. It is powered from the BAC and has no batteries.
The motion sensor for the integrated PASS and the sensor for measuring absorbed temperature are both located in the display
unit.
The BAC, HUD and DDU activates when the SCBA cylinder valve is opened.
Optional SpiroLink Telemetry system is available (see Chapter 7). Optional Tracking system is available (see Chapter 8).
The data log information can be downloaded to a PC using the data log transfer software “BacTalk” and a USB dongle. Contact
Interspiro for additional information.
The PASS can be used without having the SCBA pressurised and is activated by pressing the red alarm button on the DDU. This
will activate the PASS and start the Alarm mode, reset the PASS by pressing and holding the black backlight button and then
simultaneously pressing the red alarm button on the DDU. The PASS is now in Sensing mode.
1.9 Optional Cylinder Quick Coupling
The SCBA can be equipped with a cylinder quick coupling as an option. The regulator unit is then connected to the cylinder
valve by simply pushing them together. When the SCBA is pressurised the quick coupling is locked and not possible to
disconnect. With the SCBA evacuated of air the quick coupling can be disconnected by pushing the locking ring and then
removing the regulator unit from the cylinder valve.
The quick coupling fits 4500 psi cylinders with the use of an adaptor on the cylinder valve. The adapter is installed on the
cylinder valve with a torque of 40 Nm (29.5 lb ft).
Cylinders with the adapter can be re-filled without removing the adapter. Interspiro offers a quick connect cylinder charging
adapter, p/n 31602-01, for existing fill hoses.
If the adapter is removed the cylinder can be filled with a standard fill hose.
10
2 Preparations for use
2.1 Battery Installation / Replacement
To reduce the risk of ignition of a flammable atmosphere, batteries must only be changed in an area known to be non-
hazardous.
Attention! Changez de piles que dans une zone non-hazardeuse.
Immediate replacement of the batteries is necessary when the low battery alarm has activated. The Low Battery Alarm
will activate when the batteries reach a level of approximately 2 hours of operating time remaining. INTERSPIRO, Inc.
assumes no liability for mechanical, electrical or other types of battery failure.
Do not mix battery manufacturers or old with new batteries.
11
2.4 Harness Adjustment
The harness should be adjusted to ensure that the majority of the weight is
carried on the hip, not on the shoulder. To accommodate for different body sizes
the height of the harness can be adjusted by altering the distance between the hip
belt and the shoulder harness.
To adjust the harness push the two red buttons located beneath the hip belt
together. Slide the hip belt up or down until it clicks into the correct position.
There are four different positions, S, M, L and XL. The selected position is
indicated with red squares next to the letters “S”, “M”, “L” and “XL” engraved
in the backplate. The size indication is visible from both sides of the harness.
The height adjustment can be made with cylinder mounted and also with SCBA
installed in a fire truck.
2. Open the toggle link on the harness and check that the strap loop is big
enough for the cylinder to be used. If not, press the small locking hook and
enlarge the diameter of the loop.
3. Slide the cylinder into the strap loop and push it in until the valve snaps into
its holder and locks (The cylinder valve connection thread should be on the
opposite side of the toggle link). Adjust the strap loop by pushing the strap
into the guide plate until it fits snugly around the cylinder making sure that
the hook on the side engages in one of the oblong holes.
12
FOR VERSION WITH HAND WHEEL CONNECTOR:
5. Connect the regulator unit to the cylinder valve. Tighten the handwheel
connector by hand.
5. Align the quick coupling in the regulator unit with the quick coupling adapter
on the cylinder valve. Push the regulator unit together with the cylinder valve
until it “clicks” into position.
6. Check that the hoses are positioned correctly with the RIC fitting pointing upward and positioned against the cylinder.
13
2.6 Connecting the Face Mask
2. Lock it into position by sliding down the outer speech cone and tighten the
screw by hand. In the correct position the serial number on the breathing valve is
covered by the lip of the speech cone.
4. Connect the breathing valve to the medium pressure supply hose and the by-pass
unit. The locking sleeve of the female quick coupling will automatically move
forward and snap into place, locking the breathing hose in place.
5. Pull lightly on the breathing hose to check that the quick connection is securely
locked.
14
2.7 Linking the HUD
The HUD must be linked together with the SCBA (BAC) before use. The linking only needs to be performed once as long as the
same SCBA (BAC) and HUD will be used together. If a SCBA will be used with different HUDs it has to be linked before each
use.
The linking of the HUD can only be performed with the SCBA unpressurised. The HUD must be within 2 feet from the BAC
during linking. There must be no other units in linking mode within 10 feet of the unit being linked.
1. Press and hold the black button on the Digital Display Unit until the display reads
“CONNECTING”.
Magnet to
activate HUD
when linking.
3. When removing the Digital display unit the red light goes out and the yellow continues to light. The HUD and BAC are
now searching for each other.
4. Within approximately 20 seconds the HUD and BAC will link. The BAC beeps, the Digital display reads “HUD
CONNECTED” and all six LEDs in the HUD flash two times.
Warning! If not all LEDs on the HUD are lit it must immediately be removed from service.
5. Press and hold the black button on the Digital display until it switches off.
15
3 Understanding the S7 HUD, DDU and BAC
3.1 Understanding the Heads-Up Display (HUD)
The wireless HUD contains six LED indicators for user information. The four LED indicators Green (1), Yellow (2), Yellow
(3), and Red (4) on the left side (as worn) are for cylinder pressure. The Red (5) and yellow (6) LED on the right side are status
indicators.
#4
#3
#2 #5
#1 #6
Pressure reading
The HUD starts automatically when the SCBA is pressurised and presents the cylinder pressure.
Cylinder pressure: Indicated by HUD LEDs:
Full to 3/4 Green (1), Yellow (2), Yellow (3), and Red (4) ON
3/4 to 1/2 Yellow (2), Yellow (3), and Red (4) ON
1/2 to 1/4 Yellow (3) and Red (4) Flashing
1/4 to Empty Red (4) Flashing
Shutdown
Shutdown of the HUD occurs automatically when the SCBA is switched off. The HUD will shut down with all six LEDs
simultaneously flashing 2 times and then shutting off.
If the HUD shuts down during use, the user must leave the contaminated area.
16
3.2 Understanding the Digital Display
LCD Digital display
Mechanical
pressure gauge
Backlight and
scroll button
Alarm button (Black)
Magnet to activate Mechanical warning
(Red)
HUD when linking, whistle
see section 2.6.
The LCD Digital display can show four different values:
Priority 1: Cylinder pressure symbol
Priority 2: Cylinder pressure in psi
Priority 3: Remaining time
Priority 4: Absorbed temperature
The Priority 1 information is visible on the Display at all times. To activate the backlight press the black backlight button once.
The Display is now illuminated for 10 seconds.
To change to Priority 2, Priority 3 and Priority 4 values press the black backlight repeatedly when the backlight is activated, this
will toggle between values. When the backlight is switched off after 10 seconds the display returns to show Priority 1 value.
The settings of the Display unit are optional. The priorities may be different or the display may show only one or two different
values depending on the settings.
The backlight is automatically illuminated in red for 10 seconds at 50% cylinder pressure or at the “Dynamic Turn Back signal”
level (see section 6.4). This is the “Turn Back signal” to the fire fighter during use (see section 6.4). At cylinder pressures
above the “Turn Back signal”, the backlight is illuminated in the color yellow when the backlight button is pressed. At cylinder
pressures below the “Turn Back signal”, the backlight color is red when the backlight button is pressed.
The cylinder pressure symbol is displayed as a graphical symbol in four steps,
“Full”, “3/4”, “1/2” and “1/4”.
A battery symbol is always shown on top right corner of the display. The symbol
show the battery capacity in four steps. With the low battery warning indicating
2 hours battery time remaining the symbol starts to flash and a warning sound is
repeated every 20 seconds. The battery symbol and warning sound indicates battery
status in the BAC only, not the HUD.
During use, the remaining air time is calculated based on the previous air
consumption. Since the value is calculated, the displayed time can be both shorter
or longer than the actual remaining time, depending on the previous and future work
load and rate of breathing. The remaining time information must only be used as a
complement to the cylinder pressure information. Low air warnings must always be
heeded, regardless of the remaining time indication. Until the first value is calculated
from the air consumption, the display shows “CALC...”. The first value is displayed when there has been a significant pressure
drop, normally after one to two minutes of breathing.
The remaining time is shown as calculated time remaining in minutes until the “1/4” pressure level is reached.
The absorbed temperature is measured inside the DDU and shown in Fahrenheit.
As an optional setting a temperature alarm can be activated. When the absorbed temperature reaches the pre-set temperature
level the alarm will start with warnings beeps and the Display unit will read “TEMP !!!”. The “TEMP !!!” indication disappears
after 10 seconds or when the black button is pressed. The “TEMP !!!” indication and the warnings beeps are repeated every 20
seconds.
17
3.3 Understanding the BAC
Sender for tracking
system (optional)
Sound outlet
LED ramp
The BAC is positioned between the cylinder and backplate with two identical sides visible to the left and the right of the
cylinder. Both sides have an LED ramp working as location lights and indicators for PASS mode and low air warning. The red
and yellow flashing LEDs on both sides of the BAC are synchronized to flash with the respective red and yellow LEDs on the
Digital Display Unit (DDU). Sound outlets for PASS pre-alert and PASS alarm are located on both sides.
The BAC can be equipped with one tracking sender on each side as an option.
With the low battery warning indicating 2 hours battery time remaining a warning sound is emitted every 20 seconds.
When not pressurized, low battery in the BAC is indicated by flashing red LEDs and sound beeps.
Note: If the BAC indicates low battery when not pressurized there could be less than 2 hours operation left.
18
4 Leakage and function test
Caution!
Prior to and after use, perform a visual inspection of all plastic, rubber and metal parts for damage. If any damaged
parts are found the SCBA must be taken out of service and repaired according to the SPIROMATIC S7 Service Manual.
Repairs are to be made by INTERSPIRO or a holder of an INTERSPIRO Service Certificate.
1. Open the ambient air hatch by pressing down the hatch lever and gently
pushing out the exhalation valve cover.
3. Turn on the positive pressure by closing the ambient air hatch. A strong
flow of air should be heard.
5. The BAC emits a sound and the BAC and DDU LEDs start to flash yellow
indicating PASS Sensing mode. The digital display activates.
6. Check that the PASS pre-alert and alarm modes are operational as described in the section 6.2 and section 6.3.
Warning!
Failure to ensure that the PASS is fully operational prior to use may expose the user to serious injury or loss of life.
Although the PASS meets all current NFPA specifications, there is no inherent guarantee against PASS failure. Even the
best PASS cannot compensate for abuse or the lack of a PASS training and maintenance program.
Limitation!
SPIROMATIC S7 that include an integrated PASS are only approved for use as an integrated SCBA/PASS system. If the
PASS is not fully functional then SPIROMATIC S7 must be removed from service.
Note!
Although PASS can be checked for proper operation, most performance properties of the PASS can not be tested by the
end user in the field.
7. With the cylinder valve still open and the positive pressure turned off, check that the cylinder pressure is indicated on the
DDU and in the HUD.
19
9. Close the cylinder valve. The needle of the mechanical pressure gauge
should not move during one minute: If it does - indicating leakage -
repairs should be made by an authorized service personnel and the test
repeated.
Note: The cylinder valve pressure gauge, shoulder mounted pressure
gauge, and HUD must read full prior to use. NFPA 1404 requires
that air cylinders of all SCBA shall be maintained at not less than 90
percent of the rated pressure stamped on the cylinder.
10. With the cylinder closed, open the by-pass valve slightly in order to allow the air to slowly evacuate. Read the mechanical
pressure gauge when HUD Yellow and Red LEDs begin to flash. The pressure gauge should read 1/2 full.
Note: The pressure indication displayed in the HUD is refreshed every 2 seconds.
Continue to slowly evacuate the air and read the pressure gauge when the mechanical whistle starts to sound, the visual
red LED only on the HUD starts to flash, and the red LED on the BAC and DDU starts to flash. The pressure gauge should
read 1/4 full.
For the SPIROMATIC S7 HP (4500 psi), the alarm should sound at approximately 1125 psi.
For the SPIROMATIC S7 LP (2216 psi) the alarm should sound at approximately 554 psi.
Note!
If the sound level of the low air warning whistle seems to be below normal, remove the unit from service. Service the low
air whistle according to the INTERSPIRO Service Manual. This must be carried out by a holder of an INTERSPIRO
Service Certificate.
Note!
The regulator has a safety nozzle at the high pressure hose connection. The safety nozzle limits the loss of air in the event
of a high pressure hose or gauge leak. During a function test of the low air warning it is important that the air pressure
be reduced slowly to allow the pressure to pass back through the safety nozzle. If the secondary pressure is reduced more
quickly than the high pressure air can be reduced to reach the activation pressure, the whistle may not have sufficient
air to sound and the function test should be repeated.
11. When the alarm sounds, turn the by-pass valve to the “OFF” position.
Caution!
The by-pass valve must be returned to its closed position prior to the remaining air being released from the system.
Failure to close the by-pass valve will cause the by-pass to be in the “ON” position which will cause a free flow of air
when the cylinder is turned on for next use.
13. To turn the unit off press and hold the black backlight button and then simultaneously press the red alarm button when the
system has evacuated fully.
20
5 Donning
Caution!
Training in the donning and before use test procedure should
be given before use in an emergency situation. The user must
demonstrate proficiency to a responsible teacher or supervisor.
1. Extend the shoulder and waist strap buckles and put on the
apparatus with the cylinder valve facing downwards.
3. Extend the waist strap and insert the male buckle into the female
buckle.
7. Open the ambient air hatch by pressing down the hatch lever and
gently pushing out the exhalation valve cover.
8. Reach back with your right hand and open the cylinder valve fully.
9. The BAC emits a sound and the BAC and DDU LEDs start to
flash yellow to indicate PASS Sensing mode. The digital display
activates.
10. Check that cylinder pressure is then indicated on the HUD LED’s.
11. Fully extend the straps of the head harness by grasping the head
harness buckles and extending the head harness straps. Don the
SPIROMATIC S7 mask by grasping the lower two head harness
straps and pulling the head harness over your head. Ensure the
mask is properly fitted on your face with the chin positioned in the
chin cup. Pull down the back tail of the head harness to position
the head harness properly and check that no straps are twisted.
Moderately tighten the head harness straps by pulling straight back,
not out, beginning with the lower two straps first, the upper two
straps next, and then the top center strap. Readjust if necessary.
21
Important!
The SPIROMATIC S7 facemask is available in three sizes: Small, Large, and X-Large. The standard size facemask is
the Large size. The Small mask has a smaller size mask body and the small size inner mask. The X-Large mask has a
X-Large mask body and the Large inner mask. Contact Interspiro at (800)-468-7788 for more information.
Note!
OSHA 1910.134 mandates annual fit testing and allows the use of either quantitative or qualitative fit test methods.
NFPA 1500, Standard on Fire Department Occupational Safety and Health Program, 2007 Edition requires fit testing
of SCBA face masks and only allows quantitative fit testing. Interspiro recommends that quantitative fit testing be used
as the best and most reliable test method. Fit testing must be accomplished prior to using the SPIROMATIC S SCBA
and annually thereafter. The OSHA fit testing requires testing in the negative pressure mode and the SPIROMATIC S7
mask requires the use of an Interspiro fit test adapter p/n 95991-01. Contact Interspiro at (800)-468-7788 for additional
information.
12. Close the hatch by pushing it back in position and breathe normally from the apparatus. Stop breathing and listen for any
leakage. If you hear any leakage, check that your hair is not interfering with the face seal. Readjust the head harness if
necessary.
13. Check operation of the by-pass by opening the valve and ensure a good flow of
air into the face mask. Close the by-pass.
14. Check the positive pressure by holding your breath and inserting two fingers
between the sealing edge and your face. A strong sound of escaping air should be
heard. Take out your fingers again. No sound of escaping air should be heard thus
indicating that the facepiece is properly sealed against the face.
15. Check that the pressure shown on the mechanical pressure gauge, DDU and HUD
reads full. The apparatus is now ready for use.
Warning!
If the cylinder has been charged very fast, the air in the cylinder is warm
and the volume available for breathing is reduced.
Caution!
Special training should be given for emergency operations, with
particular attention to the by-pass valve and the cylinder valve when the
SPIROMATIC S is used with a uniform, chemical suit and tools.
Caution!
When donning the SPIROMATIC S7 SCBA take care that nothing
interferes (i.e. helmet, turnout gear, accessories) and remains free and clear
with the proper wearing or functioning of the unit. Eye glasses shall not be
used when the temple bars interfere with the proper seal of the facemask to the face. If a user must wear corrective
lenses while wearing the SCBA, an Interspiro NIOSH Approved spectacle kit must be used. Contact Interspiro at
(800)-468-7788 for additional information.
22
6 During Use
6.1 PASS Sensing Mode
In this mode the Digital Display Unit (DDU) is active showing the cylinder pressure symbol, the PASS is activated and the HUD
displays pressure according section 3.1. The LEDs on the DDU and BAC are flashing yellow to indicate PASS Sensing mode
and to act as location lights.
Check cylinder pressure indication from time to time when using the apparatus.
Note!
NFPA 1404 requires written standard operating procedures for training in the use of respiratory protection equipment
that shall include an individual air management program. NFPA 1404 states that the air management program should
include the following directives:
(1) Exit from IDLH atmosphere should be before consumption of reserve air supply begins.
(2) Low air alarm is notification that the individual is consuming the reserve air supply.
(3) Activation of the reserve air alarm is an immediate action item for the individual and the team.
Caution!
The user must heed the low air warning and start retreating immediately. Correct planning and training for any
operation involving the use of breathing apparatus is essential.
Warning!
If the HUD shuts down the user must leave the contaminated area.
23
Note!
If the apparatus is used at ambient temperatures of 32ºF or below and wetted with water, external icing can cause
malfunctions of the acoustic warning device. In the case of low temperatures the apparatus pressure gauge must be read
more frequently.
24
1. Verify that the cylinder valve is in the open position.
2. Remove the charge port dust plug and rotate the male UAC outwards to the
charging position.
3. Verify that the charging whip with the mating female quick coupling is charged
with breathing quality air.
4. Rotate the UAC coupling outward and firmly push the female quick coupling with
pin straight onto the male charging port of the RIC UAC. The locking sleeve of the
female quick coupling will automatically move forward and snap in place, locking
the charging hose into place.
5. Allow the cylinder to fill. Charge rate is dependent on the inlet pressure and the
pressure remaining in the cylinder.
6. When any audible filling has ended or the cylinder gauge reads full, firmly grasp
the female quick coupling and pull back on the locking sleeve to release the female
quick coupling and remove it from the charge port.
7. Install the dust plug onto the charge port and store the tether by rotating the cap.
Limitations!
In the supplied air mode of operation, the SCBA is approved for entry into hazardous atmosphere. The supplied air must
be respirable air meeting the requirements of the Compressed Gas Association Specifications G-7 for Type 1 Grade D air
or equivalent and supplied at 60 to 125 PSI. Cylinder valve must remain closed during supplied air use.
25
6.8 Buddy Breathing
The supplied air hose can be connected to another breathing apparatus for buddy breathing without the use of an extra hose.
Background regulations: OSHA 29 CFR Part 1910 Final Rule: Fire Brigades:
“Approved self-contained breathing apparatus may be equipped with either a “buddy-breathing” device or a quick
disconnect valve, even if these are not certified by NIOSH. If these accessories are used, they shall not cause damage to the
apparatus, or restrict the air flow of the apparatus, or obstruct the normal operation of the apparatus”.
Although allowed for in accordance with OSHA, the use of the SPIROMATIC S hose for buddy-breathing is not NIOSH
approved.
Limitations!
Buddy Breathing shall only be used for emergency operations. When possible, a rescue team with full cylinders shall
be sent in at the scene by officer in charge to attempt the rescue operation.
Caution!
If a rescue is to be attempted by a person already involved in an incident, that person shall have at least 1/2 full
cylinder pressure remaining in his/her own cylinder. Any person attempting a rescue shall communicate with the
officer in charge and receive the command from him/her before proceeding.
The person making the rescue shall remove the Y-coupling rescue hose from the
left hip pouch of his/her own SCBA and from the person to be rescued. The rescuer
shall connect the Y-couplings together.
Push the female connector of one Y-coupling onto the male coupling of the other.
The locking sleeve of the quick coupling will automatically move forward and snap
into place, locking the hoses together.
Gently pull the hoses to ensure, that the couplings are secure.
The rescuer shall listen for a strong flow of air from the SCBA of the person to be
rescued.
A: A strong flow of air would indicate a leakage on the SCBA of the person
to be rescued. If a strong leakage is heard, disconnect the rescue hose
before the donor loses his/her own air. Then call for a rescue team and use
INTERSPIRO’s Revitox mask.
B: If a strong flow of air leakage is not heard, proceed together and leave the
contaminated area.
26
7 Telemetry Functions - Configuration Option
The SPIROMATIC S7 can be equipped with an optional SpiroLink Telemetry system. To enable the telemetry functions the
SCBA telemetry unit is mounted into the backplate of the SCBA and connected to the BAC. It is required to have a version of
the S7 having the telemetry cable installed in the BAC.
1. Loosen the screw and release the hose connector from the locking clip
located at the cylinder docking device.
Slot
27
5. Use the two screws supplied with the SCBA telemetry unit to
screw it together with the backplate using a T25 Torx screw
driver.
Use a Phillips screwdriver to unscrew the screws holding the battery cover. Remove the battery covers and replace batteries
according orientation marked in the battery compartment. Check O-ring and replace battery cover and tighten the screws
moderately.
28
7.3 Preparation for Use
To enable automatic registering on the outside incident Command Entry Control Unit the fire fighter’s name and team
association can be transferred to the SCBA telemetry unit using the SpiroLink ID system.
The ID system is described in the separate instruction for the RFID system.
Press and hold the black backlight button on the DDU until the display reads “CONNECTING”. The telemetry unit LED lights
up blue.
Put the ID card in front of the RFID symbol on the telemetry unit. Successful transfer is indicated with a beep sound and display
reads “WELCOME – #FIRE FIGHTER NAME# – #TEAM NAME#”.
Press the black backlight button on the DDU to confirm and then hold the button to switch the SCBA off. If not pressed, the
SCBA will switch off automatically after 3 minutes.
RFID
symbol
Should the link to the Entry Control Unit be lost a warning sound is activated and the display alternates between normal display
and “NO LINK !!!” indication.
When the link is established again the unit returns to normal display automatically.
29
With the link established, the cylinder pressure, remaining time and absorbed temperature are continuously sent from the SCBA
to the Entry Control unit.
Alarms for low air, man down and panic alarm (manual activation of alarm) are automatically sent to the Entry Control unit.
If the alarms are sent when there is no link to the Entry Control Unit it will be pending in the system and transmitted when the
link is established again.
If the alarms for man down (lack of motion) and panic alarm are confirmed on the Entry Control Unit the text “CONFIRMED”
will appear on the SCBA display after some moments.
Press the black backlight button to put the unit back to normal display.
When an evacuation signal sent from the outside incident Command Entry Control unit is activated on the SCBA, an alarm
sound is started and the display starts to flash showing “EVAC!!!” on the display.
The left side of the HUD flashes Green, Yellow and Yellow LEDs.
To acknowledge the evacuation signal, the user presses and holds the black backlight button on the DDU and then
simultaneously presses the red alarm button.
When the signal is acknowledged the alarm sound is switched off. The display continues to flash and alternates between “EVAC
!!!” and normal display.
Note!
If the red alarm button is pressed before the backlight button, or if the backlight button is released before the red alarm
button is pressed, the unit will be put in PASS Alarm mode. Re-set the PASS according section 6.3 and then acknowledge
the evacuation signal.
A flashing battery symbol next to the antenna symbol indicates if there is a low battery condition in the telemetry unit. When this
warning starts there is a minimum of 2 hours of operation remaining.
30
8 Tracking Functions - Configuration Option
An optional S7 tracking system includes two (one on each side of the BAC) Summit Safety PathfinderTM Firefighter Beacons
integrated into the Interspiro S7 PASS device (See section 3.3). When the firefighter’s PASS device goes into alarm, the Beacon
transmits a specific ultrasound signal. The tracking symbol is activated on the DDU
A separate hand-held RIT Tracker is capable of detecting and following this transmitted signal, leading the Rapid Intervention
Team (RIT) along the PATH to the distressed firefighter. The RIT Tracker is described in a separate operating instruction.
When the S7 SCBA cylinder valve is opened and the SCBA is charged, the S7 integrated PASS and the Beacons turn on. When
the S7 PASS goes into alarm mode, the Beacons transmit the Pathfinder signal, allowing the firefighter to be located quickly. The
PathfinderTM Firefighter Beacon frequency is 41,67 kHz.
31
9 Doffing
1. Open the ambient air hatch. Remove the face mask by loosening the lowest head harness straps first.
2. Undo the waist belt buckle.
Note!
After use or at any stand-by time prior to use, an optional neck strap or an optional clip on the shoulder strap to
secure the mask is available. Contact Interspiro for more information.
3. Pull the shoulder strap buckles upwards and the straps will automatically loosen. Take off the apparatus by sliding it under
the right arm and forward.
4. Close the cylinder valve.
5. Bleed off the air pressure by turning the positive pressure on (close the ambient air hatch).
6. Press and hold the black backlight button and then simultaneously press the red alarm button to switch the unit off.
32
10 Cleaning and maintenance
Regulations state that respirators must be regularly cleaned and disinfected. Furthermore, respirators that are used by more than
one person must be cleaned and disinfected after each use.
Caution!!
Service beyond the following procedures must be handled by a holder of an INTERSPIRO Service Certificate!
33
3. Remove HUD from inside the facemask.
Note!
Small lugs protruding on the inside of the visor (one on each side) secure the HUD inside the mask.To remove the
HUD, grasp the HUD on one side (right or left) and gently pull the HUD towards the middle of the mask. When the
HUD is past the inside edge of the lug on the inside of the visor, the HUD will be free to lift up and out of the face
mask.
4. Prepare a solution of hospital grade cleaner/disinfectant, i.e.: Georgia Steel special respirator cleaner FK 300, Clean Gear II
or equivalent, using warm (approximately 100 degree F) water.
5. The mask should be submerged and scrubbed using a soft bristled brush. In addition to scrubbing the outside surface of
the face mask, the inside sealing surfaces of the face mask that touch the face should also be scrubbed using a soft bristled
brush. The inside of the visor should not be scrubbed as this could adversely affect the anti-fog coating. To ensure complete
disinfection, refer to the respirator cleaner manufacturers instructions.
6. Rinse the face mask well in clean water. Detergent residue may cause rubber components to “gum” up.
7. Dry the mask using a soft towel. Ensure that excess water is removed from the air channels and sealing edges and perform
a visual inspection of the face mask before reassembly.
Caution!
Alcohol or products containing alcohol must not be used for cleaning of the face mask or other rubber based
materials.
10. If it is deemed necessary to clean the demand valve and/or regulator, care must be taken to prevent water from entering
either of these components. Do not submerge the breathing valve or the HUD. The outside of the breathing valve can be
cleaned with a damp cloth and warm water. The outside of the HUD can be cleaned and disinfected using a cloth dampened
with the same cleaner/disinfectant used for the face mask.
Important!
All parts must be completely dry before re-assembly. This is especially important under extreme cold conditions.
34
SERVICE AND TESTING SCHEDULE
The schedule showsInminimum
case of doubt consult your
requirements local Interspiro
for service representative.
and testing as recommended by Interspiro.
Local requirements may differ due to regulations and environmental conditions.
10.5
SERVICE AND TESTING SCHEDULE
The schedule shows minimum requirements for service and testing as recommended
representative.
and testing Preventive
as recommended
Maintenance
environmental conditions.
equipment.
Interspiro.
Maintenance
by
EVERY Interspiro.
EVERY 10
Local requirements BEFORE AFTER EVERY conditions.
Thismay differ due
schedule to regulations
is valid for SCBA and environmental
equipment. 2nd V
Inminimum
case of doubt USE
consult your USE
local Interspiro YEAR
representative. YEARS
# APPARATUS / COMPONENT
The schedule shows requirements for service and testing as recommended
YEARby Interspiro.
EVERY EVERY 10
Local requirements may differ dueBEFORE
to regulationsAFTER EVERY conditions.
and environmental 2nd
The below schedule #1shows the minimum
Breathing
APPARATUS Apparatus In requirements for your
case of doubt consult
/ COMPONENT service and testing
Ulocal Interspiro
USE C USE asPreventive
IIrecommended
I Urepresentative.
IYEAR T YEAR by Interspiro.
Local requirements
Maintenance
YEARS
V
Pressure
132 c.
Full
b. Face
Breathing
Medium
Inlet Regulator
Mask
filter & Warning
& Breathing
Apparatus
pressure hoses Device
Valve U
I C DII I U I II T R III I RII+IV
II
a. High
Pressure
Full pressure
Face
423 Harness
c. Medium Mask connection
Regulator O-ring(s)
& Warning
& Breathing
pressure hoses Device
Valve I DI I I R III I RII+IV
II
b. Inlet filter
a. High
Pressure
453 Cylinder
Harness pressure connection
/Regulator
Cylinder O-ring(s)
& Warning
Pack Device I I II R III R II
c. Medium
b.Cylinder
a.
5 a. pressure
Inlet filter
High
Cylinder pressure hoses
connection
/ Cylinder Pack O-ring(s) I II IPeriodic
II inspection I II+IV
R III in accordance
with national regulations.
Harness
4 b.
c. Cylinder
b.
a. Medium pressure
Inlet filter hoses
valve, service parts I I I isperiodic
Service
samewith
advised
Periodic toIII
inspection
national
beinperformed
Rinterval accordancein the
I II+IV
as cylinders.
regulations.
Cylinder
54 b. Medium/ pressure
Harness
c. Cylinder Cylinder
valve, Pack
hoses
service parts I I I IIis advised to be performed
Service in the
I II+IV
same periodic interval as cylinders.
Periodic inspection in accordance
a. Cylinder/ Cylinder Pack
Cylinder
45 Harness I I
If necessary. I II
with national regulations.
U = Short user test
Service is advised to beinperformed
II Environmental
I IPeriodic
II and
conditions inspection
frequency of usein the
accordance
C b.
5 Cylinder
U =
valve, service
a. Cylinder/ Cylinder Pack parts
I If necessary. same periodic
with interval
national as cylinders.
regulations.
= Cleaning
Short user test must be considered. Frequent use and/or use in
b.
I =Cylinder
a. valve, service parts II aggressive Service
environments
Environmental conditions is may
Periodicadvised
and leadto be
inspectiontoinperformed
frequency of usein the
accordance
shorter
C Inspection
= Cleaning inspection/maintenance samewith
must be considered. Frequent
periodic interval
national
intervals. as cylinders.
regulations.
use and/or use in
Service is may
advised to be
toperformed
shorter in the
D
I b.= aggressive environments lead
U ==Cylinder valve, service parts
Disinfection
Inspection
Short user test
III
I Frequency of use must
If necessary.
inspection/maintenance samebeperiodic
considered.
intervals.interval as cylinders.
T
D = Disinfection
Performance test on a calibrated IVII Medium pressure
Environmental hoses older
conditions andthan 15 years
frequency of(from
use
C III
U == I date
Frequency of use must be considered.
No. 97307F01
Cleaning If necessary.
must ofbemanufacture) shall not use
considered. Frequent be used.
and/or use in
= test
Short user
unit by test
certified technician
TI = Performance test on a calibrated IV aggressive
VIII Applies
Medium
Environmentalenvironments
pressureconditions
to SCBA’s
may
hoses older
delivered
lead
than
andafter 15toyears
frequency shorter
January of(from
use
1,
C ==
97307F01
R
U Inspection
= Renew,
Cleaning If
datenecessary.
inspection/maintenance
mustofbemanufacture)
considered. shallintervals.
not use
Frequent be used.
and/or use in
= Short
test service parts
user
unit by test
certified technician 2008. For older equipment, see Product Bulletin
DI = Disinfection VII aggressive
Environmental
III Applies
30095.
Frequency environments
of use
to SCBA’s must be may
conditions
delivered lead
andafter
considered. to shorter
frequency
January of 1,
use
C
R = Inspection
Part.
== Cleaning
Renew, service parts inspection/maintenance
must
2008. be considered.
For older equipment, intervals.
Frequent use and/or
see Product use in
Bulletin
Part. No.
T
D = Performance IV aggressive
Medium pressure hoses older than 15
environments may lead to shorter years (from
I Disinfection test on a calibrated III 30095.
No. 97307F01
=
= Inspection Frequency
date of use mustshall
of manufacture) be considered.
not be used.
test unit by certified technician inspection/maintenance intervals.
T
D = Performance test on a calibrated IV Applies
V Medium to pressure
SCBA’s hoses older after
delivered than 15 years (from
January 1,
= Disinfection III Frequency of use must be considered.
97307F01
R = Renew, date
2008. of
Formanufacture) shallsee
not Product
be used.Bulletin
test unitservice partstechnician
by certified older equipment,
T = Performance test on a calibrated IV
V Medium
30095. to
Applies
pressure hoses older than 15 years (from
SCBA’s delivered after January 1,
97307F01
Part.
R = Renew, date of manufacture) shall not be used.
test unitservice partstechnician
by certified 2008. For older equipment, see Product Bulletin
No.
V Applies
30095. to SCBA’s delivered after January 1,
R = Renew, service parts
Part.
2008. For older equipment, see Product Bulletin
Part. No.
30095.
Prior to and after use, perform a visual inspection of all plastic, rubber (elastomeric) and metal parts for damage. Inspect
elastomeric parts for splitting, cracking, or holes. If any damaged parts are found the SCBA must be taken out of service
and repaired according to the SPIROMATIC S7 Service Manual. Repairs are to be made by INTERSPIRO or a holder of an
INTERSPIRO Service Certificate.
To ensure that your SCBA is working properly a complete test at least once a year must be performed, even if it has not been
used. These tests are carried out on the SPIROMATIC S test equipment which enables you to test all SPIROMATIC S functions
and identify areas requiring repair.
For SCBAs used daily check cylinder pressure every day.
For SCBAs in storage check cylinder pressure every week.
The short user test before and after use is to be carried out in accordance with the instructions in this manual.
35
Warning!
The minimum test and service procedures are intended for normal use only. If the SCBA has been exposed to extreme
conditions such as extreme heat or cold, harsh liquids or chemicals, heavy duty dust particles, or extreme shock or
vibration, the SCBA must undergo a test and inspection by a holder of an INTERSPIRO Service Certificate. If the SCBA
does not meet the values in the SPIROMATIC S Test Instruction or if it shows signs of wear, the SCBA must be taken out
of service and repaired according to the SPIROMATIC S7 Service Manual.
Warning!
Except for cleaning, lubrication, inspection and test procedures according to this Operating Instruction, only the holder
of an INTERSPIRO Repair Certificate should service the SPIROMATIC S7 Self-Contained Breathing Apparatus. Work
by unauthorized or untrained persons and/or the use of other than INTERSPIRO parts may void the approval and
safety of the unit.
36
11 SpiroGuide electronics configuration and PASS data
logging
The S7 SpiroGuide electronic system has standard default settings for the BAC and DDU.Optional settings, depending on the
preference of the Fire Department, are available and can be set by an Interspiro certified service technician using the BACTalk
program while the BAC is placed in the “Service mode”. A separate BACTalk User manual describes how the Interspiro
certified service technician can change the default configuration settings.
11.1 Default and Configuration Optional Settings for the BAC and DDU
Digital Display Unit (DDU) values
The default settings show four different values in the following order:
Priority 1: Cylinder pressure symbol
Priority 2: Cylinder pressure in psi
Priority 3: Remaining time
Priority 4: Absorbed temperature
The priorities may be set in any different order and any or all of the different values may be turned OFF. (see section 3.2)
Remaining Time Calculation
The default setting calculates the remaining time from FULL (starting cylinder pressure at 90%-100% FULL) to the low air
alarm warning level. The Remaining time calculation optional setting is from FULL (starting cylinder pressure at 90%-100%
FULL) to zero (EMPTY) cylinder pressure. (see section 3.2)
Electronic Low Air Warning
The default setting is OFF. A mechanical whistle is the primary audible low air warning and can not be silenced in the BACTalk
program. The optional electronic low air warning (audible electronic whistle sound) can be turned ON in the
BACTalk program. The electronic low air warning also has an optional mutable function in the BACTalk program depending on
the preference of the Fire Department. If mutable, the electronic low air warning will be silenced for 10 seconds by pressing the
backlight button on the DDU (see section 3.2 and 6.4)
DDU Turn Back Signal
The default setting is at 50% cylinder pressure (same as the HUD flashing yellow and red LEDs at 50% cylinder pressure, see
section 3.1). The backlight of the DDU is automatically illuminated in red for 10 seconds at 50% cylinder
pressure which is the “Turn Back signal” to the firefighter. (see section 6.4). An optional Dynamic Turn Back signal can be used
depending on the preference of the Fire Department. The dynamic signal activates at a level automatically calculated by the
SCBA. The level is set halfway between the initial starting pressure and the low air warning level.
Integrated PASS
The S7 SCBA with Integrated PASS is the standard S7 default configuration. The S7 SCBA is NFPA 1981 and 1982, 2007
certified including the integrated PASS. As an option, the PASS can be turned OFF in the BAC Talk program. When the PASS is
turned OFF, the S7 is certified to NFPA 1981, 2007 as an SCBA.
Start-up Self-Test
An automatic Start-up Self-Test option is available (start-up test default setting is OFF). The automatic start-up test option can
be turned ON in the BACTalk program by a certified service technician. There are two start-up tests, a short test and a full test,
that are performed when the breathing apparatus is pressurized. The Short Test requires no user interaction. The results of the
test are presented on the Digital Display Unit and must be acknowledged by the user before proceeding. The short test checks
cylinder pressure and the electronics and warning functions.
During the full test, motion sensor, panic button and the pressure tightness of the breathing apparatus are checked with a
minimum of user interaction. Note: The Leakage and function test of the S7 (see section 4) and the checks during donning (see
section 5) still need to be performed by the User, even if the automatic Start-up Self-Test option is activated. Generally the Start-
up Self-Test option is used only by a certified service technician, but can be activated for all Fire Department user’s depending
on the preference of the Fire Department.
37
INTERSPIRO, Inc.
10225 82nd AVENUE
PLEASANT PRAIRIE, WI
Publ. No. 31440C01
53158
USA
PHONE 262-947-9901
FAX 262-947-9902