0% found this document useful (0 votes)
323 views30 pages

Cable Gland Catalogue New-1

This document provides information on COMET single compression type heavy duty cable glands, including their applications, materials, finishes, accessories, and fitting sequence. The glands are weatherproof and intended for indoor use. They are typically made of brass and nickel plated, with alternative materials including stainless steel and aluminum. Rubber sealing rings and threaded entries of BSC or other standards are also detailed.

Uploaded by

Bala Krishnan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
323 views30 pages

Cable Gland Catalogue New-1

This document provides information on COMET single compression type heavy duty cable glands, including their applications, materials, finishes, accessories, and fitting sequence. The glands are weatherproof and intended for indoor use. They are typically made of brass and nickel plated, with alternative materials including stainless steel and aluminum. Rubber sealing rings and threaded entries of BSC or other standards are also detailed.

Uploaded by

Bala Krishnan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 30

Profile SIN

CE 60
19

After serving the electrical industry for 5 decades, has traveled a long way.
The metamorphosis is from a small manufacturer of cable glands to a leader in the
manufacture of not only Cable Glands but also of Terminals and Connectors.
It has surged across the horizon of India's electrical industry.

To meet the demands of this high-precision sector, has perfected the art of
excellence. The brand has evolved around a strong determination to achieve the highest
standards of quality. Backed by meticulous research and techno-savvy innovation,

connects as the OEM product of prestigious electrical brands.

Our motto is to provide innovative products concentrating solely on quality, which has
been endorsed by our valued customers, who approve of for their regular supplies.
We take this opportunity to thank all our customers for their unflinching support and
reiterate our commitment of uncompromising quality. Our continuous upgrading and
rigorous pursuit at each and every stage ensures the best product by our dedicated

designing team.
Like in the past, your valued suggestions and feedback had been sincerely accepted and
successfully implemented wherever possible and the same zest is anticipated. This would
help in our rigorous pursuit of excellence.

V. S. DEDHIA
CHAIRMAN
General Information
SIN
CE 60
19

Classification
Cable Glands are classified according to the type
a. Single compression
b. Double compression
1. Weatherproof - Armored / Un-armored
2. Flameproof suitable for Gas Group I, IIA & IIB - Armored / Un-armored
3. Flameproof suitable for Gas Group IIC - Armored / Un-armored

Selection guidelines for cable glands


determine condition of use, i.e. industrial, hazardous area.
determine environment conditions.
determine type of cable, armoured or non-armoured.
determine type of armour and thickness, where applicable.
determine cable overall diameter.
determine entry hole type and size

Gland Design Entry threads


COMET gland design and testing philosophy on Glands are supplied with B.S.C. threads (ET).
the performance requirements of BS 6121 : 2005 Other entry thread forms available are - NPT, PG,
(BS EN 50262) & IP67 as per IS 13947 (Part I), PF, BSP METRIC etc.
adding any criteria necessary to meet particular
specification.
How to order
Hazardous area glands - Approvals
Select appropriate gland from the relevant table
COMET flameproof glands are approved by by checking the ACTUAL cable dimensions or
CIMFR - Dhanbad, DGFASLI, CCOE - NAGPUR. referring to the SPECIFIED cable.
Suitable for - GAS I, IIA, IIB & IIC.
Specific details are available upon request.
Dimensions
Materials
Alternatively if you would prefer us to recommend
Glands are manufactured as standard in BRASS. a gland to meet your requirement, please quote :
Alternative material includes ALUMINIUM, S.S &
M.S Full cable description and dimensions or cable
Finishes specification and conductor size, gland reference.

Brass glands are generally supplied with NICKEL Entry thread required if other than BSC.
finish and can be supplied with variety of finishes,
e.g. CHROME, TIN or CADNIUM. Further details are Accessories
available upon request.
Accessories e.g. shroud, earth tags are supplied
separately and should be specified when ordering
the gland.
WIDEST APPROVALS
SIN
CE 60
19

( A Govt of India Undertaking )

ON
TCE

EC
M
TCE Consulting Engineers Limited
IS ny
O9
001 Co m p a

JE

P D IL
TOYO INDIA

DEVELOPMENT CONSULTANTS PVT. LTD.

Dalal Con sultants


And Engineers P v t . Ltd

AVANT-GARDE
ENGINEERS AND CONSULTANTS (P.) LTD.

KSHI JHOHN BROWN


AND MANY MORE .......
COMET Single Compression Type Heavy Duty Cable
Gland (SIBG Series) SIN
CE 60
19

3
Application :
For use under most climatic conditions and generally for indoor use.
These are Weather proof and may be used in the corrosive condition 5
when protected by a shroud.

Materials & Finishes : Accessories :


M. O. C : Shrouds and Earth tags are supplied separately
a. Cable Gland is manufactured in Brass (standard). and should be specified when ordering the gland.
b. Alternative material - Stainless Steel / Aluminium.

Sealing Ring : Natural Rubber Fitting sequence :


Thread : 1) Pass item 5, item 3 and item 4 over cable
Technical Data

a. Glands are supplied with B.S.C. thread (ET) as before commencing to strip over sheath.
standard.
b. Alternative thread forms available are - NPT / 2) Remove the outer sheath to the desired length
PG / BSP / MM etc. depending on the length of leads required.

Finish : 3) Pass item 3 over the cable and splay out the
a. Nickel Plated (standard) armour wire one by one and then cut the
b. Alternative Plating - Tin / Cadmium / Chrome armour wires according to the size of washer.
Insert the third metal washer over inner sheath
Protection Class: IP 60 of cable so that bend armour are secured
between the two metal washers.
Ref. Standard : IS 12943
4) Push the cable through item 2 and engage the
Specifications : item 5 with item 2 and tighten up while doing,
so the grooved rubber ring will contract in radial
Gland consist of checknut 1, gland body direction and will grip the outer sheath of cable.
2, metal washers (3 Nos.) 3, outer seal
rubber ring 4, compression nut 5, All metal 5) Screw item 2 into apparatus (secure with item 1
parts are made of brass accurately machined if plain hole entry.)
for ease of assembly (except item 3).
COMET Single Compression Type Heavy Duty Cable
Gland (SIBG Series) SIN
CE 60
19

C A B F

COMET

D
E

Cable Dimensions Gland Dimensions


SIBG A B Entry Thread E F
SERIES (Under armour (Over all Dia) C D (Across Flat) (Across
Dia) mm mm (Inches) (Length) mm Corner) mm
mm

1616 9.0 15.0 5/8” 8.5 25.0 29.0

1619 10.0 15.0 3/4” 8.5 25.0R 29.0

2119 14.0 20.0 3/4” 9.5 30.5 35.0

2125 14.0 20.0 1” 9.5 30.5 35.0

2925 20.0 26.0 1” 10.0 40.0 46.0

2932 24.0 29.0 1.1/4” 10.0 40.0 46.0

2938 24.0 29.0 1.1/2” 10.0 40.0 46.0

3638 31.0 37.0 1.1/2” 11.0 49.0 56.0

4251 36.0 42.0 2” 11.0 60.0 68.0

5451 44.0 50.0 2” 12.0 67.0 77.0

5463 44.0 50.0 2.1/2” 12.0 67.0 77.0

6063 54.0 60.0 2.1/2” 12.0 78.0 88.0

6675 60.0 66.0 3” 13.0 84.0 96.0

7882 70.0 77.0 3.1/4” 14.0 98.0 112.0


Comet Weatherproof Type Double Compression Cable
Gland Suitable For Armoured Cables SIN
CE 60
19

- 1
- 2

- 3

- 4
- 5
- 6

- 7

- 8
Application : - 9
For use under most climatic conditions & generally for armored cables &
outdoor use. These are Weather proof and may be used in the corrosive
condition when protected by a shroud.
- 10

Materials & Finishes : Specifications :


M. O. C : Gland consist of locknut 1, washer 2,
a. Cable Gland is manufactured in Brass (standard). armour clamping nut 3, neoprene inner ring 4,
b. Alternative material - Stainless Steel / Aluminium. armour clamping cone 5, armour clamping ring 6,
gland body 7, neoprene outer ring 8, skid washer 9
Sealing Ring : Neoprene Rubber & outer seal nut 10, All metal parts are made of
Technical Data

brass accurately machined for ease of assembly.


Thread :
a. Glands are supplied with B.S.C. thread (ET) as
standard.
b. Alternative thread forms available are - NPT /
PG / BSP / MM etc.
Fitting sequence
Finish :
1) Pass item 10,9,8,7 respectively over cable before
a. Nickel Plated (standard)
commencing to strip oversheath.
b. Alternative Plating - Tin / Cadmium / Chrome
2) Remove the outer sheath and pass item 6 over
Protection Class: IP 67 as per IS 13947 Part I exposed armour.
3) Cut armour to length, lift wire ends, pass item 5
Ref. Standard : BS 6121 : 2005 (BS EN 50262) over exposed bedding, and beneath armour.
4) Pass item 4.
5) Pass cable end through item 3.
Accessories 6) Engage item 7 and 3 and tighten up.
7) Engage item 10 and 7 and tighten up.
Shrouds and Earth tags are supplied separately 8) Screw item 3, 2 into apparatus (secure with
and should be specified when ordering the gland. item 1 if plain hole entry.)
COMET Weatherproof Type Double Compression
Cable Gland Suitable For Armoured Cables SIN
CE 60
19

E CA B

COMET
F D

Cable Dimensions Gland Dimensions


CBW A B Armour Entry Thread E F
(Under (Over (Across (Across
SERIES diameter C D
armour Dia) all Dia) Flat) Corner)
mm mm mm (Inches) (Length) mm mm
mm
CBW01SS 8.0 12.0 0.8/1.4 3/4” 15.0 21.5 24.5
CBW01S 11.0 16.5 0.8/1.4 3/4” 15.0 25.0 29.0
CBW01 12.0 18.0 0.8/1.4 3/4” 15.0 28.0 32.0
CBW01A 12.0 18.0 0.8/1.4 1” 15.0 28.0 32.0
CBW02 14.0 20.0 0.8/1.4 1” 15.0 31.5 36.5
CBW02A 14.0 20.0 0.8/1.4 3/4” 15.0 31.5 36.5
R
CBW03 17.0 23.0 0.8/1.4 1” 15.0 32.0 37.0
CBW04 20.0 26.0 0.8/1.4 1” 15.0 38.0 44.0
CBW04A 20.0 26.0 0.8/1.4 1.1/4” 15.0 38.0 44.0
CBW05 24.0 30.0 0.8/1.4 1.1/4” 15.0 41.0 47.0
CBW05A 24.0 30.0 0.8/1.4 1.1/2” 15.0 41.0 47.0
CBW06 27.0 33.0 0.8/1.4 1.1/2” 15.0 47.0 54.0
CBW06A 27.0 33.0 0.8/1.4 1.1/4” 15.0 47.0 54.0
CBW07 30.0 37.0 0.8/1.4 1.1/2” 15.0 52.0 58.0
CBW08 35.0 41.0 0.8/1.4 2” 15.0 56.0 64.0
CBW09 40.0 46.0 0.8/1.4 2” 15.0 59.0 67.0
CBW010 46.0 52.0 0.8/1.4 2” 20.0 66.5 77.0
CBW010A 46.0 52.0 0.8/1.4 2.1/2” 20.0 66.5 77.0
CBW011S 50.0 56.0 0.8/1.4 2.1/2” 20.0 74.0 85.0
CBW011 54.0 60.0 0.8/1.4 2.1/2” 20.0 80.0 92.0
CBW012 60.0 66.0 0.8/1.4 3” 20.0 85.0 97.0
CBW013A 66.0 72.0 0.8/1.4 3” 20.0 90.0 103.0
CBW013 72.0 78.0 0.8/1.4 3.1/4” 20.0 99.0 113.0
CBW014 78.0 84.0 0.8/1.4 3.1/2” 20.0 105.0 122.0
CBW015 88.0 94.0 0.8/1.4 4” 20.0 117.0 135.0
CBW016 98.0 105.0 0.8/1.4 4.1/2” 20.0 130.0 149.0
COMET Weatherproof Type Double Compression
Cable Gland Suitable For Un-Armoured Cables SIN
CE 60
19

- 1
- 2

- 3

- 4

- 5

- 6
- 7
- 8
Application :
For use under most climatic conditions & generally for un-armored cables
& outdoor use. These are Weather proof and may be used in the corrosive
condition when protected by a shroud.

Materials & Finishes : Specification :


M. O. C : Gland consist of locknut 1, washer 2,
a. Cable Gland is manufactured in Brass (standard). armour clamping nut 3, neoprene inner ring 4,
b. Alternative material - Stainless Steel / Aluminium. gland body 5, neoprene outer ring 6,
skid washer 7 & outer seal nut 8. All metal parts
Sealing Ring : Neoprene Rubber are made of brass accurately machined for ease
Technical Data

of assembly.
Thread :
a. Glands are supplied with B.S.C. thread (ET) as
standard.
b. Alternative thread forms available are - NPT / Fitting sequence
PG / BSP / MM etc. 1) Pass item 8,7,6,5,4 & 3 respectively over
cable.
Finish :
a. Nickel Plated (standard) 2) Engage item 5 and 3 and tighten up.
b. Alternative Plating - Tin / Cadmium / Chrome
3) Engage item 8 and 5 and tighten up.
Protection Class: IP 55 as per IS 13947 Part I

Ref. Standard : BS 6121 : 2005 (BS EN 50262) 4) Screw item 3, 2 into apparatus (secure with
item 1 if plain hole entry.)

Accessories
Shrouds and Earth tags are supplied separately and
should be specified when ordering the gland.
COMET Weatherproof Type Double Compression
Cable Gland Suitable For Un-Armoured Cables SIN
CE 60
19

E C A B

COMET
F D

Cable Dimensions Gland Dimensions


Entry Thread E F
CBW A B (Across
(Dia) mm (Dia) mm C D (Across Flat)
SERIES Corner)
(Inches) (Length)
mm mm mm

CBW01SS (UN) 13.0 13.0 3/4” 15.0 21.5 24.5


CBW01S (UN) 14.5 14.5 3/4” 15.0 25.0 29.0
CBW01A (UN) 18.0 18.0 1” 15.0 R
28.0 32.0
CBW02 (UN) 20.0 20.0 1” 15.0 31.5 36.5
CBW03SP (UN) 23.0 23.0 M28 15.0 32.0 37.0
CBW04A (UN) 26.0 26.0 1.1/4” 15.0 38.0 44.0
CBW05A (UN) 30.0 30.0 1.1/2” 15.0 41.0 47.0
CBW06SP (UN) 33.0 33.0 M40 15.0 47.0 54.0
CBW07SP (UN) 36.0 36.0 M42 15.0 52.0 58.0
CBW08 (UN) 41.0 41.0 2” 15.0 56.0 64.0
CBW09 (UN) 44.0 44.0 2” 15.0 59.0 67.0
CBW010A (UN) 52.0 52.0 2” 20.0 66.5 77.0
CBW011SP (UN) 60.0 60.0 M70 20.0 80.0 92.0
CBW012 (UN) 66.0 66.0 3” 20.0 85.0 97.0
CBW013 (UN) 72.0 72.0 3.1/4” 20.0 90.0 103.0
CBW014 (UN) 80.0 80.0 3.1/2” 20.0 105.0 122.0
CBW015 (UN) 90.0 90.0 4” 20.0 117.0 135.0
COMET Flameproof Type Double Compression Cable Gland
Suitable For Armoured Cables For Gas Group II A / II B SIN
CE 60
II
19

- 1
- 2

- 3

- 4
- 5
- 6

- 7

- 8
Application : - 9
For use under hazardous climatic conditions & generally for armored cables
& outdoor use. These are weatherproof & may be used in the corrosive - 10
conditions when protected by a shroud.

Materials & Finishes : Specification :


M. O. C : Gland consist of lock nut 1, washer 2,
a. Cable Gland is manufactured in Brass (standard). armour clamping nut 3, neoprene inner ring 4,
b. Alternative material - Stainless Steel / Aluminium. armour clamping cone 5, armour clamping ring 6,
gland body 7, neoprene outer ring 8, skid washer 9
Sealing Ring : Neoprene Rubber & outer seal nut 10. All metal parts are made of
brass accurately machined for ease of assembly.
Technical Data

Thread :
a. Glands are supplied with B.S.C. thread (ET) as Accessories
standard. Shrouds and Earth tags are supplied separately
b. Alternative thread forms available are - NPT / and should be specified when ordering the gland.
PG / BSP / MM etc.

Finish :
Fitting sequence
a. Nickel Plated (standard)
1) Pass item 10,9,8,7 respectively over cable
b. Alternative Plating - Tin / Cadmium / Chrome
before commencing to strip oversheath.
2) Remove the oversheath and pass item 6 over
Protection Class: IP 66 as per IS 13947 Part I
exposed armour.
3) Cut armour to length, lift wire ends, pass item 5
Ref. Standard : IS 2148 : 2004(IEC 60079-1 : 2001)
over exposed bedding, and beneath armour.
4) Pass item 4.
Approvals : 5) Pass cable end through item 3.
6) Engage item 7 and 3 and tighten up.
COMET flameproof glands are approved by 7) Engage item 10 and 7 and tighten up.
Central Mining Research Institute, Dhanbad. 8) Screw item 3, 2 into apparatus (secure with
(Approved by CIMFR, DGFASLI, CCOE - NAGPUR) item 1 if plain hole entry.)
COMET Flamerproof Type Double Compression Cable
Gland Suitable For Armoured Cables For Gas Group II A / II B SIN
CE 60
19

Cable Dimensions Gland Dimensions


CBF A B Entry Thread E F
(Under (Over Armour D (Across (Across
SERIES C
armour Dia) all Dia) diameter (Length) Flat) Corner)
mm mm (Inches) mm mm mm
CBF01SS 8.0 13.0 0.8/1.4 3/4” 25.0 21.5 24.5
CBF01S 11.0 16.5 0.8/1.4 3/4” 25.0 25.0 29.0
CBF01 12.0 18.0 0.8/1.4 3/4” 25.0 28.0 R 32.0
CBF01A 12.0 18.0 0.8/1.4 1” 25.0 28.0 32.0
CBF02 14.0 20.0 0.8/1.4 1” 25.0 31.5 36.5
CBF02A 14.0 20.0 0.8/1.4 3/4” 25.0 31.5 36.5
CBF03 17.0 23.0 0.8/1.4 1” 25.0 32.0 37.0
CBF04 20.0 26.0 0.8/1.4 1” 25.0 38.0 44.0
CBF04A 20.0 26.0 0.8/1.4 1.1/4” 25.0 38.0 44.0
CBF05 24.0 30.0 0.8/1.4 1.1/4” 25.0 41.0 47.0
CBF05A 24.0 30.0 0.8/1.4 1.1/2” 25.0 41.0 47.0
CBF06 27.0 33.0 0.8/1.4 1.1/2” 25.0 47.0 54.0
CBF06A 27.0 33.0 0.8/1.4 1.1/4” 25.0 47.0 54.0
CBF07 30.0 37.0 0.8/1.4 1.1/2” 25.0 52.0 58.0
CBF08 35.0 41.0 0.8/1.4 2” 25.0 56.0 64.0
CBF09 40.0 46.0 0.8/1.4 2” 25.0 59.0 67.0
CBF010 46.0 52.0 0.8/1.4 2” 25.0 66.5 77.0
CBF010A 46.0 52.0 0.8/1.4 2.1/2” 25.0 66.5 77.0
CBF011S 50.0 56.0 0.8/1.4 2.1/2” 25.0 74.0 85.0
CBF011 54.0 60.0 0.8/1.4 2.1/2” 25.0 80.0 92.0
CBF012 60.0 66.0 0.8/1.4 3” 25.0 85.0 97.0
CBF013A 66.0 72.0 0.8/1.4 3” 25.0 90.0 103.0
CBF013 72.0 78.0 0.8/1.4 3.1/4” 25.0 99.0 113.0
CBF014 78.0 84.0 0.8/1.4 3.1/2” 25.0 105.0 122.0
CBF015 88.0 94.0 0.8/1.4 4” 25.0 117.0 135.0
CBF016 98.0 105.0 0.8/1.4 4.1/2” 25.0 130.0 149.0
COMET Flameproof Type Double Compression Cable
Gland Suitable For Armoured Cables For Gas Group II C SIN
CE 60
II
19

- 1
- 2
- 3

- 4
- 5
- 6
- 7
- 8
Application : - 9
For use under hazardous climatic conditions & generally for armored cables
& outdoor use. These are weatherproof & may be used in the corrosive
conditions when protected by a shroud.
- 10

Materials & Finishes : Specification :


M. O. C : Gland consist of lock nut 1, washer 2, armour
a. Cable Gland is manufactured in Brass (standard). clamping nut 3, neoprene inner ring 4,
b. Alternative material - Stainless Steel / Aluminium. armour clamping cone 5, armour clamping ring 6,
gland body 7, neoprene outer ring 8,skid washer 9
Sealing Ring : Neoprene Rubber & outer seal nut 10. All metal parts are made of
brass accurately machined for ease of assembly.
Technical Data

Thread :
a. Glands are supplied with B.S.C. thread (ET) as Accessories
standard.
b. Alternative thread forms available are - NPT / Shrouds and Earth tags are supplied separately
PG / BSP / MM etc. and should be specified when ordering the gland.
Fitting sequence
Finish :
a. Nickel Plated (standard) 1) Pass item 10,9,8,7 respectively over cable
b. Alternative Plating - Tin / Cadmium / Chrome before commencing to strip oversheath.
2) Remove the oversheath and pass item 6 over
Protection Class: IP 66 as per IS 13947 Part I exposed armour.
3) Cut armour to length, lift wire ends, pass item 5
Ref. Standard : IS 2148 : 2004(IEC 60079-1 : 2001) over exposed bedding, and beneath armour.
4) Pass item 4.
5) Pass cable end through item 3.
Approval 6) Engage item 7 and 3 and tighten up.
COMET flameproof glands are approved by 7) Engage item 10 and 7 and tighten up.
Central Mining Research Institute, Dhanbad. 8) Screw item 3, 2 into apparatus (secure with
(Approved by CIMFR) item 1 if plain hole entry.)
COMET Flameproof Type Double Compression Cable
Gland Suitable For Armoured Cables For Gas Group II C SIN
CE 60
19

Cable Dimensions Gland Dimensions


A B Entry Thread E F
CBFIIC (Under (Over Armour (Across (Across
C D
SERIES armour Dia) all Dia) diameter Flat) Corner)
mm mm (Inches) (Length) mm mm
mm
CBFIIC01SS 8.0 13.0 0.8/1.4 3/4” 25.0 21.5 24.5
CBFIIC01S 11.0 16.5 0.8/1.4 3/4” 25.0 25.0 29.0
CBFIIC01 12.0 18.0 0.8/1.4 3/4” 25.0 R28.0 32.0
CBFIIC01A 12.0 18.0 0.8/1.4 1” 25.0 28.0 32.0
CBFIIC02 14.0 20.0 0.8/1.4 1” 25.0 31.5 36.5
CBFIIC02A 14.0 20.0 0.8/1.4 3/4” 25.0 31.5 36.5
CBFIIC03 17.0 23.0 0.8/1.4 1” 25.0 32.0 37.0
CBFIIC04 20.0 26.0 0.8/1.4 1” 25.0 38.0 44.0
CBFIIC04A 20.0 26.0 0.8/1.4 1.1/4” 25.0 38.0 44.0
CBFIIC05 24.0 30.0 0.8/1.4 1.1/4” 25.0 41.0 47.0
CBFIIC05A 24.0 30.0 0.8/1.4 1.1/2” 25.0 41.0 47.0
CBFIIC06 27.0 33.0 0.8/1.4 1.1/2” 25.0 47.0 54.0
CBFIIC06A 27.0 33.0 0.8/1.4 1.1/4” 25.0 47.0 54.0
CBFIIC07 30.0 37.0 0.8/1.4 1.1/2” 25.0 52.0 58.0
CBFIIC08 35.0 41.0 0.8/1.4 2” 25.0 56.0 64.0
CBFIIC09 40.0 46.0 0.8/1.4 2” 25.0 59.0 67.0
CBFIIC010 46.0 52.0 0.8/1.4 2” 25.0 66.5 77.0
CBFIIC010A 46.0 52.0 0.8/1.4 2.1/2” 25.0 66.5 77.0
CBFIIC011S 50.0 56.0 0.8/1.4 2.1/2” 25.0 74.0 85.0
CBFIIC011 54.0 60.0 0.8/1.4 2.1/2” 25.0 80.0 92.0
CBFIIC012 60.0 66.0 0.8/1.4 3” 25.0 85.0 97.0
CBFIIC013A 66.0 72.0 0.8/1.4 3” 25.0 90.0 103.0
CBFIIC013 72.0 78.0 0.8/1.4 3.1/4” 25.0 99.0 113.0
COMET Nylon Type Cable Gland
SIN
CE 60
19

Technical Data
Material : Nylon (Polyamide)
Finish : White / Grey / Black colour
Application : Generally for flexible cables

PG THREAD
Cable Range (mm) Size Panel Hole Dia.
3.0 - 6.5 PG 7 13.0
4.0 - 8.0 PG 9 16.0
5.0 - 10.0 PG 11 19.0
6.0 - 12.0 PG 13.5 21.0
10.0 - 14.0 PG 16 23.0
13.0 - 18.0 PG 21 29.0
18.0 - 25.0 PG 29 38.0
22.0 - 32.0 PG 36 48.0
30.0 - 38.0 PG 42 55.0
34.0 - 44.0 PG 48 60.0

MM THREAD
Cable Range (mm) Size Panel Hole Dia.
3.0 - 6.5 M12 13.0
4.0 - 8.0 M16 17.0
5.0 - 12.0 M20 21.0
10.0 - 18.0 M25 26.5
16.0 - 25.0 M32 34.0
22.0 - 32.0 M40 42.0
30.0 - 36.0 M50 52.0
34.0 - 45.0 M63 65.0
COMET Cable Glands Accessories
SIN
CE 60
19

COMET WEATHERPROOF TYPE STOPPING PLUGS


Materials & Finishes :
M. O. C : a. Brass (standard).
b. Alternative material - Stainless Steel / Aluminium.
Thread : a. B.S.C. thread (ET) as standard.
b. Alternative thread forms available are - NPT / PG / BSP / MM etc.
Finish : a. Nickel Plated (standard)
b. Alternative Plating - Tin / Cadmium / Chrome
Range : 1/2" to 3"
Application : To close any unused entries.

COMET FLAMEPROOF TYPE STOPPING PLUGS SUITABLE


FOR GAS GROUP II A, II B & IIC
Materials & Finishes :
M. O. C : a. Brass (standard).
b. Alternative material - Stainless Steel / Aluminium.
Thread : a. B.S.C. thread (ET) as standard.
b. Alternative thread forms available are - NPT / PG / BSP / MM etc.
Finish : a. Nickel Plated (standard)
b. Alternative Plating - Tin / Cadmium / Chrome
Range : 1/2" to 3"
Application : To close any unused entries.

COMET WEATHERPROOF TYPE REDUCER / ADAPTOR


Materials & Finishes :
M. O. C : a. Brass (standard).
b. Alternative material - Stainless Steel / Aluminium.
Thread : a. B.S.C. thread (ET) as standard.
b. Alternative thread forms available are - NPT / PG / BSP / MM etc.
Finish : a. Nickel Plated (standard)
b. Alternative Plating - Tin / Cadmium / Chrome
Range : 1/2" to 3"
Application : Used when enclosures entry is different from gland entry.

COMET FLAMEPROOF TYPE REDUCER / ADAPTOR


SUITABLE FOR GAS GROUP II A, II B & II C
Materials & Finishes :
M. O. C : a. Brass (standard).
b. Alternative material - Stainless Steel / Aluminium.
Thread : a. B.S.C. thread (ET) as standard.
b. Alternative thread forms available are - NPT / PG / BSP / MM etc.
Finish : a. Nickel Plated (standard)
b. Alternative Plating - Tin / Cadmium / Chrome
Range : 1/2" to 3"
Application : Used when enclosures entry is different from gland entry.

COMET SHROUDS COMET EARTH TAG


M. O. C : PVC / LSF / FRLS M. O. C : Brass / SS / Aluminum
Application : For protecting the gland from Application : For earthing purpose.
climatic conditions.
COMET Export Series
SIN
CE 60
19

COMET BW TYPE CABLE GLANDS


Materials & Finishes :
M. O. C : Brass
Finish : Natural
Range : 20mm to 90mm
Ref. Standard : BS - 6121
Application : Generally for dry indoor situation & indoor gland for plastic or rubber
insulated, insulated, single wire armored, plastic or rubber over
sheathed cables.

COMET CW TYPE CABLE GLANDS WITH OUTER SEAL


Materials & Finishes :
M. O. C : Brass
Finish : Natural
Range : 20mm to 90mm
Ref. Standard : BS - 6121
Application : Generally for dry outdoor situation gland for plastic or rubber insulated,
single wire armored, Plastic or rubber sheathed cables. Cables with
extruded or lapped bedding.

COMET A1 / A2 TYPE CABLE GLANDS WITH OUTER SEAL


Materials & Finishes :
M. O. C : Brass
Finish : Natural
Range : 20mm to 90mm
Ref. Standard : BS - 6121
Application : Generally purpose gland for plastic or rubber insulated, unarmored plastic
or rubber oversheated cables.

COMET WIPING GLANDS


Materials & Finishes :
M. O. C : Brass
Finish : Natural
Range : Type X, Y & Z
Application : Generally used in transformers & switchgear as per customers requirement.

COMET COPPER HEAVY DUTY TERMINALS


(WITH INSPECTION HOLE)
Materials & Finishes :
M. O. C : Copper
Finish : Electro - Tinned
Range : 1.5mm2 to 1000mm2
Application : Generally for XLPE conductors. Manufactured in line with DIN standards.
Single Core Aluminum / Copper Conductor ,
XLPE Insulated, Un-armoured Cables 1100 Volts SIN
CE 60
19

SINGLE COMPRESSION TYPE DOUBLE COMPRESSION TYPE


Approx.
No.of Nipple entry
overall Medium Heavy Nipple Weatherproof Flameproof
Cores for W/P
diameter duty duty entry type (CBW) type (CBF)
& F/P
1x4 9.5 5/8” 1619 + 1611 3/4” CBW01SS CBF01SS 3/4”
1x6 10.0 5/8” 1619 + 1611 3/4” CBW01SS CBF01SS 3/4”
1 x 10 11.0 5/8” 1619 + 1611 3/4” CBW01SS CBF01SS 3/4”
1 x 16 12.5 3/4” 1619 + 1613 3/4” CBW01SS CBF01SS 3/4”

* Cable Data collected from leading manufacturers of cable. Variation in dimensions of cables is beyond our liability
For Un-Armoured Cables

1 x 25 13.0 3/4” 1619 + 1613 3/4” CBW01SS CBF01SS 3/4”


1 x 35 14.5 3/4” 1619 + 1615 3/4” CBW01S CBF01S 3/4”
1 x 50 14.5 3/4” 1619 + 1615 3/4” CBW01S CBF01S 1”
1 x 70 15.5 1” 2125 + 2116 1” CBW01A CBF01A 1”
1 x 95 16.5 1” 2125 + 2118 1” CBW01A CBF01A 1”
1 x 120 19.0 1” 2125 + 2120 1” CBW02 CBF02 1”
1 x 150 21.0 1.1/8” 2932 + 2921 1.1/4” CBW03SP CBF03SP M28
1 x 185 23.0 1.1/8” 2932 + 2923 1.1/4” CBW04A CBF04A 1.1/4”
1 x 225 29.0 1.1/2” 2938 + 2929 1.1/2” CBW05A CBF05A 1.1/2”
1 x 240 29.0 1.1/2” 2938 + 2929 1.1/2” CBW05A CBF05A 1.1/2”
1 x 300 30.0 1.1/2” 3638 + 3631 1.1/2” CBW05A CBF05A 1.1/2”
1 x 400 33.0 1.3/4” 4251 + 4234 2” CBW06SP CBF06SP M40
1 x 500 37.0 1.3/4” 4251 + 4238 2” CBW07SP CBF07SP M42
1 x 625 41.0 2” 4251 + 4242 2” CBW08 CBF08 2”
1 x 800 49.0 2.1/4” 5463 + 5450 2.1/2” CBW010A CBF010A 2.1/2”
1 x 1000 55.0 2.1/2” 6063 + 6055 2.1/2” CBW011S CBF011S 2.1/2”
Twin Core Aluminum / Copper conductor , XLPE Insulated,
Un-armoured Cables 1100 Volts
SINGLE COMPRESSION TYPE DOUBLE COMPRESSION TYPE
Approx.
No.of Nipple entry
overall Medium Heavy Nipple Weatherproof Flameproof
Cores for W/P
diameter duty duty entry type (CBW) type (CBF)
& F/P
2x4 13.5 3/4” 1619 + 1613 3/4” CBW01S CBF01S 3/4”
2x6 14.0 3/4” 1619 + 1615 3/4” CBW01S CBF01S 3/4”
For Un-Armoured Cables

2 x 10 17.0 1” 2125 + 2118 1” CBW01A CBF01A 1”


2 x 16 18.0 1” 2125 + 2120 1” CBW01A CBF01A 1”
2 x 25 20.0 1” 2125 + 2120 1” CBW02 CBF02 1”
2 x 35 21.0 1.1/8” 2932 + 2921 1.1/4” CBW03SP CBF03SP M28
2 x 50 24.0 1.1/4” 2932 + 2925 1.1/4” CBW04A CBF04A 1.1/4”
2 x 70 27.0 1.1/4” 2938 + 2928 1.1/2” CBW05A CBF05A 1.1/2”
2 x 95 30.0 1.1/2” 3638 + 3631 1.1/2” CBW05A CBF05A 1.1/2”
2 x 120 32.0 1.1/2” 3638 + 3633 1.1/2” CBW06SP CBF06SP M40
2 x 150 35.0 1.3/4” 4251 + 4236 2” CBW07SP CBF07SP M42
2 x 185 39.0 1.3/4” 4251 + 4240 2” CBW08 CBF08 2”
2 x 240 41.0 2” 4251 + 4242 2” CBW08 CBF08 2”
2 x 300 46.0 2” 5463 + 5448 2.1/2” CBW010A CBF010A 2.1/2”
2 x 400 51.0 2.1/4” 5463 + 5450 2.1/2” CBW010A CBF010A 2.1/2”
2 x 500 57.0 2.3/4” 6675 + 6658 3” CBW011SP CBF011SP M70
2 x 630 63.0 3” 6675 + 6664 3” CBW012 CBF012 3”
Three Core Aluminum / Copper Conductor,
XLPE Insulated, Un-Armoured Cables 1100 Volts SIN
CE 60
19

SINGLE COMPRESSION TYPE DOUBLE COMPRESSION TYPE


Approx.
No.of Nipple entry
overall Medium Heavy Nipple Weatherproof Flameproof
Cores for W/P
diameter duty duty entry type (CBW) type (CBF)
& F/P

3x4 15.0 3/4” 2125 + 2116 1” CBW01A CBF01A 1”


3x6 17.0 1” 2125 + 2118 1” CBW01A CBF01A 1”
3 x 10 18.0 1” 2125 + 2118 1” CBW01A CBF01A 1”

* Cable Data collected from leading manufacturers of cable. Variation in dimensions of cables is beyond our liability
For Un-Armoured Cables

3 x 16 18.5 1” 2125 + 2120 1” CBW02 CBF02 1”


3 x 25 22.0 1.1/8” 2932 + 2923 1.1/4” CBW03SP CBF03SP M28
3 x 35 23.0 1.1/8” 2932 + 2923 1.1/4” CBW04A CBF04A 1.1/4”
3 x 50 27.0 1.1/4” 2938 + 2927 1.1/2” CBW05A CBF05A 1.1/2”
3 x 70 30.0 1.1/2” 3638 + 3631 1.1/2” CBW05A CBF05A 1.1/2”
3 x 95 33.0 1.3/4” 4251 + 4234 2” CBW06SP CBF06SP M40
3 x 120 36.0 1.3/4” 4251 + 4236 2” CBW07SP CBF07SP M42
3 x 150 39.0 1.3/4” 4251 + 4240 2” CBW08 CBF08 2”
3 x 185 44.0 2” 5451 + 5444 2” CBW09 CBF09 2”
3 x 240 50.0 2.1/4” 5463 + 5450 2.1/2” CBW010A CBF010A 2.1/2”
3 x 300 55.0 2.1/2” 6063 + 6055 2.1/2” CBW011S CBF011S 2.1/2”
3 x 400 60.0 2.3/4” 6675 + 6660 3” CBW011SP CBF011SP M70
3 x 500 68.0 3” 7882 + 7868 3.1/4” CBW013A CBF013A 3”
3 x 630 74.0 3.1/4” 7882 + 7874 3.1/4” CBW013 CBF013 3.1/4”

Three & Half Core Aluminum / Copper Conductor, XLPE Insulated,


Un-Armoured Cables 1100 Volts
SINGLE COMPRESSION TYPE DOUBLE COMPRESSION TYPE
Approx.
No.of Nipple entry
overall Medium Heavy Nipple Weatherproof Flameproof
Cores for W/P
diameter duty duty entry type (CBW) type (CBF)
& F/P

3.5 x25/16sm 23.5 1.1/4” 2932 + 2925 1.1/4” CBW04A CBF04A 1.1/4”
For Un-Armoured Cables

3.5 x35/16sm 25.0 1.1/4” 2932 + 2925 1.1/4” CBW04A CBF04A 1.1/4”
3.5 x50/25sm 28.0 1.1/2” 2938 + 2929 1.1/2” CBW05A CBF05A 1.1/2”
3.5 x70/35sm 32.0 1.1/2” 3638 + 3633 1.1/2” CBW06SP CBF06SP M40
3.5 x95/50sm 37.0 1.3/4” 4251 + 4238 2” CBW08 CBF08 2”
3.5 x120/70sm 39.0 1.3/4” 4251 + 4240 2” CBW08 CBF08 2”
3.5 x150/70sm 43.0 2” 5451 + 5444 2” CBW09 CBF09 2”
3.5 x185/95sm 48.0 2.1/4” 5463 + 5448 2.1/2” CBW010A CBF010A 2.1/2”
3.5 x240/120sm 55.0 2.1/2” 6063 + 6055 2.1/2” CBW011S CBF011S 2.1/2”
3.5 x300/150sm 60.0 2.3/4” 6675 + 6664 3” CBW011SP CBF011SP M70
3.5 x400/185sm 66.0 3” 6675 + 6666 3” CBW012 CBF012 3”
3.5 x500/240sm 73.0 3.1/4” 7882 + 7874 3.1/4” CBW013 CBF013 3.1/4”
3.5 x630/300sm 82.0 3.1/2” - - CBW015 CBF015 4”
Four Core Aluminum / Copper Conductor,
XLPE Insulated, Un-Armoured Cables 1100 Volts SIN
CE 60
19

SINGLE COMPRESSION TYPE DOUBLE COMPRESSION TYPE


Approx.
No.of Nipple entry
overall Medium Heavy Nipple Weatherproof Flameproof
Cores for W/P
diameter duty duty entry type (CBW) type (CBF)
& F/P

4x4 16.0 1” 2125 + 2116 1” CBW01A CBF01A 1”


4x6 17.5 1” 2125 + 2118 1” CBW01A CBF01A 1”
4 x 10 19.0 1” 2125 + 2120 1” CBW02 CBF02 1”

* Cable Data collected from leading manufacturers of cable. Variation in dimensions of cables is beyond our liability
For Un-Armoured Cables

4 x 16 22.5 1.1/8” 2932 + 2923 1.1/4” CBW04A CBF04A 1.1/4”


4 x 25 24.0 1.1/4” 2932 + 2925 1.1/4” CBW04A CBF04A 1.1/4”
4 x 35 27.0 1.1/4” 2938 + 2927 1.1/2” CBW05A CBF05A 1.1/2”
4 x 50 32.0 1.1/2” 3638 + 3633 1.1/2” CBW06SP CBF06SP M40
4 x 70 33.0 1.3/4” 4251 + 4234 2” CBW07SP CBF07SP M42
4 x 95 37.0 1.3/4” 4251 + 4238 2” CBW08 CBF08 2”
4 x 120 42.0 2” 4251 + 4242 2” CBW09 CBF09 2”
4 x 150 44.0 2” 5451 + 5444 2” CBW09 CBF09 2”
4 x 185 48.0 2.1/4” 5463 + 5448 2.1/2” CBW010A CBF010A 2.1/2”
4 x 240 58.0 2.3/4” 6675 + 6660 3” CBW011SP CBF011SP M70
4 x 300 65.0 3” 6675 + 6666 3” CBW012 CBF012 3”
4 x 400 70.0 3.1/4” 7882 + 7874 3.1/4” CBW013 CBF013 3.1/4”

Multi Core Copper Conductor of 1.5mm2 size, XLPE Insulated,


Un-Armoured Cables 1100 Volts
SINGLE COMPRESSION TYPE DOUBLE COMPRESSION TYPE
Approx.
No.of Nipple entry
overall Medium Heavy Nipple Weatherproof Flameproof
Cores for W/P
diameter duty duty entry type (CBW) type (CBF)
& F/P

2 x 1.5 11.0 5/8” 1619 + 1611 3/4” CBW01SS CBF01SS 3/4”


3 x 1.5 12.0 5/8” 1619 + 1613 3/4” CBW01SS CBF01SS 3/4”
4 x 1.5 13.0 3/4” 1619 + 1613 3/4” CBW01SS CBF01SS 3/4”
For Un-Armoured Cables

5 x 1.5 14.0 3/4” 1619 + 1615 3/4” CBW01S CBF01S 3/4”


6 x 1.5 15.0 3/4” 2125 + 2116 1” CBW01A CBF01A 1”
7 x 1.5 16.0 1” 2125 + 2116 1” CBW01A CBF01A 1”
10 x 1.5 17.0 1” 2125 + 2118 1” CBW01A CBF01A 1”
12 x 1.5 17.5 1” 2125 + 2118 1” CBW01A CBF01A 1”
14 x 1.5 18.0 1” 2125 + 2118 1” CBW01A CBF01A 1”
16 x 1.5 19.5 1” 2125 + 2120 1” CBW02 CBF02 1”
19 x 1.5 21.0 1.1/8” 2932 + 2921 1.1/4” CBW03SP CBF03SP M28
24 x 1.5 24.0 1.1/4” 2932 + 2925 1.1/4” CBW04A CBF04A 1.1/4”
27 x 1.5 25.0 1.1/4” 2932 + 2925 1.1/4” CBW04A CBF04A 1.1/4”
30 x 1.5 26.0 1.1/4” 2938 + 2927 1.1/2” CBW04A CBF04A 1.1/4”
37 x 1.5 27.0 1.1/4” 2938 + 2927 1.1/2” CBW05A CBF05A 1.1/2”
44 x 1.5 31.0 1.1/2” 3638 + 3631 1.1/2” CBW06SP CBF06SP M40
52 x 1.5 33.0 1.3/4” 4251 + 4234 2” CBW06SP CBF06SP M40
61 x 1.5 34.0 1.3/4” 4251 + 4234 2” CBW07SP CBF07SP M42
Multi Core Copper Conductor of 2.5mm2 size,
XLPE Insulated, Un-Armoured Cables 1100 Volts SIN
CE 60
19

SINGLE COMPRESSION TYPE DOUBLE COMPRESSION TYPE


Approx.
No.of Nipple entry
overall Medium Heavy Nipple Weatherproof Flameproof
Cores for W/P
diameter duty duty entry type (CBW) type (CBF)
& F/P

2 x 2.5 13.0 3/4” 1619 + 1613 3/4” CBW01SS CBF01SS 3/4”


3 x 2.5 13.5 3/4” 1619 + 1613 3/4” CBW01S CBF01S 3/4”
4 x 2.5 14.5 3/4” 1619 + 1615 3/4” CBW01S CBF01S 3/4”
5 x 2.5 15.5 1” 2125 + 2116 1” CBW01A CBF01A 1”

* Cable Data collected from leading manufacturers of cable. Variation in dimensions of cables is beyond our liability
For Un-Armoured Cables

6 x 2.5 17.0 1” 2125 + 2118 1” CBW01A CBF01A 1”


7 x 2.5 17.5 1” 2125 + 2118 1” CBW01A CBF01A 1”
10 x 2.5 19.5 1” 2125 + 2120 1” CBW02 CBF02 1”
12 x 2.5 20.5 1.1/8” 2125 + 2120 1” CBW03SP CBF03SP M28
14 x 2.5 22.0 1.1/8” 2932 + 2923 1.1/4” CBW03SP CBF03SP M28
16 x 2.5 23.0 1.1/8” 2932 + 2923 1.1/4” CBW04A CBF04A 1.1/4”
19 x 2.5 24.0 1.1/4” 2932 + 2925 1.1/4” CBW04A CBF04A 1.1/4”
24 x 2.5 28.0 1.1/2” 2938 + 2929 1.1/2” CBW05A CBF05A 1.1/2”
27 x 2.5 28.5 1.1/2” 2938 + 2929 1.1/2” CBW05A CBF05A 1.1/2”
30 x 2.5 29.5 1.1/2” 3638 + 3631 1.1/2” CBW05A CBF05A 1.1/2”
37 x 2.5 33.0 1.3/4” 4251 + 4234 2” CBW06SP CBF06SP M40
44 x 2.5 35.0 1.3/4” 4251 + 4235 2” CBW07SP CBF07SP M42
52 x 2.5 37.0 1.3/4” 4251 + 4238 2” CBW08 CBF08 2”

Single Core Aluminum / Copper Conductor , XLPE Insulated,


Armoured Cables 1100 Volts
SINGLE COMPRESSION TYPE DOUBLE COMPRESSION TYPE
Approx.
No.of Nipple entry
overall Medium Heavy Nipple Weatherproof Flameproof
Cores for W/P
diameter duty duty entry type (CBW) type (CBF)
& F/P

1x4 12.0 5/8” 1619 + 1613 3/4” CBW01SS CBF01SS 3/4”


1x6 12.8 3/4” 1619 + 1613 3/4” CBW01S CBF01S 3/4”
1 x 10 13.8 3/4” 1619 + 1613 3/4” CBW01S CBF01S 3/4”
1 x 16 15.0 3/4” 1619 + 1615 3/4” CBW01S CBF01S 3/4”
1 x 25 16.5 7/8” 2125 + 2116 1” CBW01S CBF01S 3/4”
For Armoured Cables

1 x 35 17.0 7/8” 2125 + 2118 1” CBW01 CBF01 3/4”


1 x 50 18.5 1” 2125 + 2120 1” CBW02 CBF02 1”
1 x 70 21.0 1.1/8” 2125 + 2120 1” CBW03 CBF03 1”
1 x 95 23.0 1.1/8” 2932 + 2923 1.1/4” CBW03 CBF03 1”
1 x 120 25.0 1.1/8” 2932 + 2925 1.1/4” CBW04 CBF04 1”
1 x 150 26.0 1.1/4” 2932 + 2925 1.1/4” CBW04 CBF04 1”
1 x 185 29.0 1.1/4” 2932 + 2929 1.1/4” CBW05 CBF05 1.1/4”
1 x 225 31.5 1.1/2” 3638 + 3631 1.1/2” CBW06 CBF06 1.1/2”
1 x 240 32.0 1.1/2” 3638 + 3633 1.1/2” CBW06 CBF06 1.1/2”
1 x 300 34.0 1.1/2” 3638 + 3637 1.1/2” CBW07 CBF07 1.1/2”
1 x 400 37.0 1.3/4” 3638 + 3637 1.1/2” CBW07 CBF07 1.1/2”
1 x 500 43.0 2” 4251 + 4242 2” CBW09 CBF09 2”
1 x 625 49.0 2.1/4” 5451 + 5448 2” CBW010 CBF010 2”
1 x 800 54.0 2.1/4” 6063 + 6055 2.1/2” CBW011S CBF011S 2.1/2”
1 x 1000 55.0 2.1/2” 6063 + 6055 2.1/2” CBW011S CBF011S 2.1/2”
Twin Core Aluminum / Copper Conductor,
XLPE Insulated, Armoured Cables 1100 Volts SIN
CE 60
19

SINGLE COMPRESSION TYPE DOUBLE COMPRESSION TYPE


Approx.
No.of Medium Heavy Nipple Weatherproof Flameproof Nipple entry
overall
Cores duty duty entry type (CBW) type (CBF) for W/P
diameter
& F/P

2 x 1.5 15.0 3/4” 1619 + 1615 3/4” CBW01S CBF01S 3/4”


2 x 2.5 16.0 7/8” 2125 + 2116 3/4” CBW01S CBF01S 3/4”
2x4 17.0 7/8” 2125 + 2118 1” CBW01 CBF01 3/4”
For Armoured Cables

2x6 18.0 1” 2125 + 2118 1” CBW01 CBF01 3/4”

* Cable Data collected from leading manufacturers of cable. Variation in dimensions of cables is beyond our liability
2 x 10 20.0 1” 2125 + 2120 1” CBW02 CBF02 1”
2 x 16 22.0 1.1/8” 2932 + 2923 1.1/4” CBW03 CBF03 1”
2 x 25 22.5 1.1/8” 2932 + 2923 1.1/4” CBW03 CBF03 1”
2 x 35 25.0 1.1/8” 2932 + 2925 1.1/4” CBW04 CBF04 1”
2 x 50 29.0 1.1/4” 2932 + 2929 1.1/4” CBW05 CBF05 1.1/4”
2 x 70 30.0 1.3/8” 3638 + 3631 1.1/2” CBW05 CBF05 1.1/4”
2 x 95 32.0 1.1/2” 3638 + 3633 1.1/2” CBW06 CBF06 1.1/2”
2 x 120 33.0 1.1/2” 3638 + 3633 1.1/2” CBW06 CBF06 1.1/2”
2 x 150 37.0 1.3/4” 3638 + 3637 1.1/2” CBW07 CBF07 1.1/2”
2 x 185 40.0 1.3/4” 4251 + 4240 2” CBW08 CBF08 2”
2 x 240 44.0 2” 5451 + 5444 2” CBW09 CBF09 2”
2 x 300 50.0 2.1/4” 5451 + 5450 2” CBW010 CBF010 2”
2 x 400 54.0 2.1/4” 6063 + 6055 2.1/2” CBW011S CBF011S 2.1/2”

Three Core Aluminum / Copper Conductor , XLPE Insulated,


Armoured Cables 1100 Volts
SINGLE COMPRESSION TYPE DOUBLE COMPRESSION TYPE
Approx.
No.of Nipple entry
overall Medium Heavy Nipple Weatherproof Flameproof
Cores for W/P
diameter duty duty entry type (CBW) type (CBF)
& F/P

3 x 1.5 15.0 3/4” 1619 + 1615 3/4” CBW01S CBF01S 3/4”


3 x 2.5 15.5 7/8” 2125 + 2116 1” CBW01S CBF01S 3/4”
3x4 18.0 1” 2125 + 2118 1” CBW01 CBF01 3/4”
3x6 19.5 1” 2125 + 2120 1” CBW02 CBF02 1”
For Armoured Cables

3 x 10 20.0 1” 2125 + 2120 1” CBW02 CBF02 1”


3 x 16 22.0 1.1/8” 2932 + 2923 1.1/4” CBW03 CBF03 1”
3 x 25 23.0 1.1/8” 2932 + 2923 1.1/4” CBW03 CBF03 1”
3 x 35 25.0 1.1/8” 2932 + 2925 1.1/4” CBW04 CBF04 1”
3 x 50 29.0 1.1/4” 2932 + 2929 1.1/4” CBW05 CBF05 1.1/4”
3 x 70 33.0 1.1/2” 3638 + 3633 1.1/2” CBW06 CBF06 1.1/2”
3 x 95 37.0 1.1/2” 3638 + 3637 1.1/2” CBW07 CBF07 1.1/2”
3 x 120 40.0 1.3/4” 4251 + 4240 2” CBW08 CBF08 2”
3 x 150 41.0 1.3/4” 4251 + 4242 2” CBW08 CBF08 2”
3 x 185 49.0 2.1/4” 5451 + 5450 2” CBW010 CBF010 2”
3 x 225 54.0 2.1/4” 6063 + 6055 2.1/2” CBW011S CBF011S 2.1/2”
3 x 240 54.0 2.1/4” 6063 + 6055 2.1/2” CBW011S CBF011S 2.1/2”
3 x 300 59.0 2.1/2” 6063 + 6060 3” CBW011 CBF011 2.1/2”
3 x 400 65.0 2.3/4” 6675 + 6666 3” CBW012 CBF012 3”
Three & Half Core Aluminum / Copper Conductor,
XLPE Insulated, Armoured Cables 1100 Volts SIN
CE 60
19

SINGLE COMPRESSION TYPE DOUBLE COMPRESSION TYPE


Approx.
No.of Nipple entry
overall Medium Heavy Nipple Weatherproof Flameproof
Cores for W/P
diameter duty duty entry type (CBW) type (CBF)
& F/P

3.5 x 25/16sm 26.0 1.1/4” 2932 + 2925 1.1/4” CBW04 CBF04 1”


3.5 x 35/16sm 28.5 1.1/4” 2932 + 2929 1.1/4” CBW05 CBF05 1.1/4”
For Armoured Cables

3.5 x 50/25sm 32.0 1.1/2” 3638 + 3633 1.1/2” CBW06 CBF06 1.1/2”

* Cable Data collected from leading manufacturers of cable. Variation in dimensions of cables is beyond our liability
3.5 x 70/35sm 35.0 1.1/2” 3638 + 3635 1.1/2” CBW07 CBF07 1.1/2”
3.5 x 95/50sm 40.0 1.3/4” 4251 + 4240 2” CBW08 CBF08 2”
3.5 x 120/70sm 43.0 2” 4251 + 4242 2” CBW09 CBF09 2”
3.5 x 150/70sm 46.0 2” 5451 + 5446 2” CBW09 CBF09 2”
3.5 x 185/95sm 50.0 2.1/4” 5463 + 5450 2.1/2” CBW010 CBF010 2”
3.5 x 225/120sm 58.0 2.1/2” 6063 + 6058 2.1/2” CBW011 CBF011 2.1/2”
3.5 x 240/120sm 59.0 2.1/2” 6063 + 6060 2.1/2” CBW011 CBF011 2.1/2”
3.5 x 300/150sm 64.0 2.3/4” 6675 + 6664 3” CBW012 CBF012 3”
3.5 x 400/185sm 72.0 3.1/4” 7882 + 7872 3.1/4” CBW013A CBF013A 3”

Four Core Aluminum / Copper Conductor , XLPE Insulated,


Armoured Cables 1100 Volts
SINGLE COMPRESSION TYPE DOUBLE COMPRESSION TYPE
Approx.
No.of Nipple entry
overall Medium Heavy Nipple Weatherproof Flameproof
Cores for W/P
diameter duty duty entry type (CBW) type (CBF)
& F/P

4 x 1.5 16.5 7/8” 2125 + 2115 1” CBW01S CBF01S 3/4”


4 x 2.5 17.0 7/8” 2125 + 2118 1” CBW01 CBF01 3/4”
For Armoured Cables

4x4 19.5 1” 2125 + 2120 1” CBW02 CBF02 1”


4x6 19.5 1” 2125 + 2120 1” CBW02 CBF02 1”
4 x 10 21.5 1.1/8” 2932 + 2923 1.1/4” CBW03 CBF03 1”
4 x 16 25.5 1.1/8” 2932 + 2925 1.1/4” CBW04 CBF04 1”
4 x 25 26.0 1.1/4” 2932 + 2925 1.1/4” CBW04 CBF04 1”
4 x 35 28.5 1.1/4” 2932 + 2929 1.1/4” CBW05 CBF05 1.1/4”
4 x 50 32.0 1.1/2” 3638 + 3633 1.1/2” CBW06 CBF06 1.1/2”
4 x 70 35.0 1.1/2” 3638 + 3635 1.1/2” CBW07 CBF07 1.1/2”
4 x 95 38.0 1.3/4” 4251 + 4238 2” CBW08 CBF08 2”
4 x 120 41.0 2” 4251 + 4242 2” CBW08 CBF08 2”
4 x 150 46.0 2” 5451 + 5446 2” CBW09 CBF09 2”
4 x 185 52.0 2.1/4” 6063 + 6053 2.1/2” CBW010 CBF010 2”
4 x 240 59.0 2.1/2” 6063 + 6060 2.1/2” CBW011 CBF011 2.1/2”
4 x 300 65.0 2.3/4” 6675 + 6666 3” CBW012 CBF012 3”
4 x 400 72.0 3.1/4” 7882 + 7872 3.1/4” CBW013A CBF013A 3”
Multi Core Copper Conductor of 1.5mm2 size,
XLPE Insulated, Armoured Cables 1100 Volts SIN
CE 60
19

SINGLE COMPRESSION TYPE DOUBLE COMPRESSION TYPE


Approx.
No.of Nipple entry
overall Medium Heavy Nipple Weatherproof Flameproof
Cores for W/P
diameter duty duty entry type (CBW) type (CBF)
& F/P

2 x 1.5 14.0 3/4” 1619 + 1615 3/4” CBW01S CBF01S 3/4”


3 x 1.5 15.0 3/4” 1619 + 1615 3/4” CBW01S CBF01S 3/4”
4 x 1.5 16.5 7/8” 2125 + 2118 1” CBW01S CBF01S 3/4”
5 x 1.5 17.0 7/8” 2125 + 2118 1” CBW01 CBF01 3/4”

* Cable Data collected from leading manufacturers of cable. Variation in dimensions of cables is beyond our liability
For Armoured Cables

6 x 1.5 17.5 1” 2125 + 2118 1” CBW01 CBF01 3/4”


7 x 1.5 17.5 1” 2125 + 2118 1” CBW01 CBF01 3/4”
10 x 1.5 20.0 1” 2125 + 2120 1” CBW02 CBF02 1”
12 x 1.5 20.5 1” 2125 + 2120 1” CBW02 CBF02 1”
14 x 1.5 20.5 1” 2125 + 2120 1” CBW02 CBF02 1”
16 x 1.5 21.5 1.1/8” 2932 + 2923 1.1/4” CBW03 CBF03 1”
19 x 1.5 22.5 1.1/8” 2932 + 2923 1.1/4” CBW03 CBF03 1”
24 x 1.5 25.5 1.1/4” 2932 + 2925 1.1/4” CBW04 CBF04 1”
27 x 1.5 26.0 1.1/8” 2932 + 2927 1.1/4” CBW04 CBF04 1”
30 x 1.5 27.0 1.1/4” 2932 + 2927 1.1/4” CBW05 CBF05 1.1/4”
37 x 1.5 29.0 1.1/4” 2938 + 2929 1.1/2” CBW05 CBF05 1.1/4”
44 x 1.5 31.0 1.3/8” 3638 + 3631 1.1/2” CBW06 CBF06 1.1/2”
52 x 1.5 32.0 1.1/2” 3638 + 3633 1.1/2” CBW06 CBF06 1.1/2”
61 x 1.5 34.0 1.1/2” 3638 + 3635 1.1/2” CBW07 CBF07 1.1/2”

Multi Core Copper Conductor , of 2.5mm2 size, XLPE Insulated,


Armoured Cables 1100 Volts
SINGLE COMPRESSION TYPE DOUBLE COMPRESSION TYPE
Approx.
No.of Nipple entry
overall Medium Heavy Nipple Weatherproof Flameproof
Cores for W/P
diameter duty duty entry type (CBW) type (CBF)
& F/P

2 x 2.5 15.0 3/4” 1619 + 1615 3/4” CBW01S CBF01S 3/4”


3 x 2.5 15.5 7/8” 2125 + 2116 1” CBW01S CBF01S 3/4”
4 x 2.5 17.0 7/8” 2125 + 2118 1” CBW01 CBF01 3/4”
5 x 2.5 19.0 1” 2125 + 2120 1” CBW02 CBF02 1”
For Armoured Cables

6 x 2.5 20.0 1” 2125 + 2120 1” CBW02 CBF02 1”


7 x 2.5 20.0 1” 2125 + 2120 1” CBW02 CBF02 1”
10 x 2.5 21.0 1.1/8” 2125 + 2120 1” CBW03 CBF03 1”
12 x 2.5 22.0 1.1/8” 2932 + 2923 1.1/4” CBW03 CBF03 1”
14 x 2.5 23.5 1.1/8” 2932 + 2923 1.1/4” CBW04 CBF04 1”
16 x 2.5 24.5 1.1/8” 2932 + 2925 1.1/4” CBW04 CBF04 1”
19 x 2.5 25.5 1. 1/8” 2932 + 2925 1.1/4” CBW04 CBF04 1”
24 x 2.5 29.0 1.1/4” 2932 + 2929 1.1/4” CBW05 CBF05 1.1/4”
27 x 2.5 30.0 1.3/8” 3638 + 3630 1.1/2” CBW05 CBF05 1.1/4”
30 x 2.5 32.0 1.1/2” 3638 + 3633 1.1/2” CBW06 CBF06 1.1/2”
37 x 2.5 34.0 1.3/8” 3638 + 3635 1.1/2” CBW07 CBF07 1.1/2”
44 x 2.5 38.0 1.1/2” 4251 + 4238 2” CBW08 CBF08 2”
52 x 2.5 39.0 1.3/4” 4251 + 4240 2” CBW08 CBF08 2”
61 x 2.5 41.0 2” 4251 + 4242 2” CBW08 CBF08 2”
Selection of Cable Gland on the Basis of Cable Overall
Diameter SIN
CE 60
19

For Double Compression Type Cable Gland (W/P & F/P) for Armoured Cables
Cable O. D. (mm) Weatherproof Flameproof Entry Thread Panel Hole. Dia
From To type (CBW) type (CBF) (ET) (mm)

8.0 - 13.0 CBW01SS CBF01SS 3/4” 21.0


13.5 - 16.0 CBW01S CBF01S 3/4” 21.0
16.5 - 18.0 CBW01 CBF01 3/4” 21.0
16.5 - 18.0 CBW01A CBF01A 1” 26.5
18.5 - 20.0 CBW02 CBF02 1” 26.5
18.5 - 20.0 CBW02A CBF02A 3/4” 21.0
20.5 - 23.0 CBW03 CBF03 1” 26.5
23.5 - 26.0 CBW04 CBF04 1” 26.5
23.5 - 26.0 CBW04A CBF04A 1.1/4” 34.0
26.5 - 30.0 CBW05 CBF05 1.1/4” 34.0
26.5 - 30.0 CBW05A CBF05A 1.1/2” 39.0
30.5 - 33.0 CBW06 CBF06 1.1/2” 39.0
30.5 - 33.0 CBW06A CBF06A 1.1/4” 34.0
33.5 - 37.0 CBW07 CBF07 1.1/2” 39.0
37.5 - 41.0 CBW08 CBF08 2” 52.0
41.5 - 46.0 CBW09 CBF09 2” 52.0
46.5 - 52.0 CBW010 CBF010 2” 52.0
46.5 - 52.0 CBW010A CBF010A 2.1/2” 65.5
52.5 - 56.0 CBW011S CBF011S 2.1/2” 65.5
56.5 - 60.0 CBW011 CBF011 2.1/2” 65.5
60.5 - 66.0 CBW012 CBF012 3” 78.0
66.5 - 72.0 CBW013A CBF013A 3” 78.0
72.5 - 78.0 CBW013 CBF013 3.1/4” 85.0
78.5 - 84.0 CBW014 CBF014 3.1/2” 91.0
84.5 - 92.0 CBW015 CBF015 4” 103.0
92.5 - 104.0 CBW016 CBF016 4.1/2” 116.0

For Double Compression Type Cable Gland (W/P & F/P) for Un-Armoured Cables

5.0 - 13.0 CBW01SS CBF01SS 3/4” 21.0


13.5 - 14.5 CBW01S CBF01S 3/4” 21.0
14.5 - 18.0 CBW01A CBF01A 1” 26.5
18.5 - 20.0 CBW02 CBF02 1” 26.5
20.5 - 22.0 CBW03SP CBF03SP M28 29.5
22.5 - 26.0 CBW04A CBF04A 1.1/4” 34.0
26.5 - 30.0 CBW05A CBF05A 1.1/2” 39.0
30.5 - 33.0 CBW06SP CBF06SP M40 41.5
33.5 - 36.0 CBW07SP CBF07SP M42 43.5
36.5 - 41.0 CBW08 CBF08 2” 52.0
41.5 - 44.0 CBW09 CBF09 2” 52.0
44.5 - 52.0 CBW010A CBF010A 2.1/2” 65.5
52.5 - 60.0 CBW011SP CBF011SP M70 72.0
60.5 - 66.0 CBW012 CBF012 3” 78.0
66.5 - 75.0 CBW013 CBF013 3.1/4” 85.0
75.5 - 80.0 CBW014 CBF014 3.1/2” 91.0
81.0 - 88.0 CBW015 CBF015 4” 103.0
Selection of Cable Gland on the Basis of Cable Overall
Diameter SIN
CE 60
19

For Single Compression Heavy Duty Type Cable Gland for Armoured Cables
Cable O. D. (mm) Entry Thread Panel Hole Dia. Equivalent SCG
Comet Code (ET) (mm) Code
From To

10.0 - 15.0 1616 5/8” 18.0 SCG2


10.0 - 15.0 1619 3/4” 21.0 SCG3
15.5 - 20.0 2125 1” 26.5 SCG4
15.5 - 20.0 2119 3/4” 21.0 SCG5
20.5 - 29.0 2925 1” 26.5 SCG6
20.5 - 29.0 2932 1.1/4” 34.0 SCG7
20.5 - 29.0 2938 1.1/2” 39.0 SCG8
29.5 - 37.0 3638 1.1/2” 39.0 SCG9
38.0 - 42.0 4251 2” 52.0 SCG10
42.5 - 50.0 5451 2” 52.0 SCG11
42.5 - 50.0 5463 2.1/2” 65.5 SCG12
51.0 - 60.0 6063 2.1/2” 65.5 SCG13
61.0 - 66.0 6675 3” 78.0 SCG14
67.0 - 78.0 7882 3.1/4” 85.0 SCG16

For Single Compression Heavy Duty Type Cable Gland for Un-Armoured Cables

Cable O. D. (mm) Entry Thread Panel Hole Dia.


Comet Code (ET) (mm)
From To

8.0 - 14.0 1619 3/4” 21.0


14.5 - 20.0 2125 1” 26.5
20.5 - 26.0 2932 1.1/4” 34.0
26.5 - 29.0 2938 1.1/2” 39.0
29.5 - 32.0 3638 1.1/2” 39.0
32.5 - 42.0 4251 2” 52.0
42.5 - 45.0 5451 2” 52.0
45.5 - 50.0 5463 2.1/2” 65.5
50.5 - 56.0 6063 2.1/2” 65.5
56.5 - 66.0 6675 3” 78.0
66.5 - 75.0 7882 3.1/4” 85.0
Selection of Cable Gland on the Basis of Cable Overall
Diameter SIN
CE 60
19

For Single Compression Medium Duty Type Cable Gland for Armoured Cables
Cable O. D. (mm) Size
(mm) Comet Code
From To

8.0 - 12.0 12 MM 1/2”


8.0 - 12.0 16 MM 5/8”
12.5 - 15.0 19 MM 3/4”
15.5 - 17.0 22 MM 7/8”
17.5 - 20.0 25 MM 1”
20.5 - 25.0 28 MM 1.1/8”
25.5 - 29.0 32 MM 1.1/4”
29.5 - 31.0 35 MM 1.3/8”
31.5 - 36.0 38 MM 1.1/2”
36.5 - 41.0 45 MM 1.3/4”
41.5 - 46.0 50 MM 2”
46.5 - 54.0 57 MM 2.1/4”
54.5 - 60.0 63 MM 2.1/2”
60.5 - 66.0 70 MM 2.3/4”
66.5 - 69.0 75 MM 3”
69.5 - 75.0 82 MM 3.1/4”
75.5 - 81.0 88 MM 3.1/2”
81.5 - 94.0 100 MM 4”

Selection of Thread Size for Cable Gland on the Basis of Cable


Overall Diameter
For Double Compression Type Cable Gland (W/P & F/P)
Cable O. D. (mm) Standard BSC Special Alternative Threads made To order
Gland Size Thread (ET)
From To NPT ISO

8.0 - 13.0 01SS 3/4” 1/2” or 3/4” M16 / M20 / M25


13.5 - 16.0 01S 3/4” 1/2” or 3/4” M16 / M20 / M25
16.5 - 18.0 01 3/4” 1/2” or 3/4” M20 / M25
18.5 - 20.0 02 1” 3/4” or 1” M20 / M25
20.5 - 23.0 03 1” 3/4” or 1” M25
23.5 - 26.0 04 1” 1” or 1.1/4” M25 / M32
26.5 - 30.0 05 1.1/4” 1” or 1.1/4” M32 / M40
30.5 - 33.0 06 1.1/2” 1.1/4” or 1.1/2” M32 / M40
33.5 - 37.0 07 1.1/2” 1.1/4” or 1.1/2” M40
37.5 - 41.0 08 2” 1.1/2” or 2” M50
41.5 - 46.0 09 2” 1.1/2” or 2” M50
46.5 - 52.0 010 2” 2” or 2.1/2” M50 / M63
52.5 - 60.0 011 2.1/2” 2” or 2.1/2” M63
60.5 - 66.0 012 3” 2.1/2” or 3” M75
72.5 - 78.0 013 3.1/4” 3” or 3.1/2” M82
78.5 - 84.0 014 3.1/2” M90
84.5 - 92.0 015 4”
92.5 - 104.0 016 4.1/2”
ENVIABLE CLIENTELE
SIN
CE 60
19

Industries Limited

HP
Bharat
Petroleum

IndianOil
DELHI METRO RAIL
CORPORATION LTD.

ACC
ACC Limited

Infrastructure

R E V

BHUSHAN

ador

Tecnimont ICB AND MANY MORE .......


ENVIABLE CLIENTELE
SIN
CE 60
19

s o Mini Ratna Category-I PSU

SAIL KPTCL JAYPEE GROUP

ADANI
LANCO
INSPIRING GROWTH
Neyveli Lignite Corporation Limited

DORR-OLIVER

Hone well

BAJAJ
Bajaj Electricals Limited

AND MANY MORE .......

You might also like