0% found this document useful (0 votes)
142 views4 pages

7 One Way Slab

1) A simply supported slab of size 4.57m x 18.28m with clear cover of 20mm and effective depth of 150mm is designed for a bar library building. 2) The slab is designed as a one-way slab with 10 numbers of 12mm diameter bars at 200mm c/c spacing in the shorter span to resist the factored bending moment of 21.38 kN-m. 3) 8 numbers of 8mm diameter bars at 240mm c/c spacing are provided in the longer span as minimum reinforcement along with shear reinforcement.

Uploaded by

Pronay Dhak
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
142 views4 pages

7 One Way Slab

1) A simply supported slab of size 4.57m x 18.28m with clear cover of 20mm and effective depth of 150mm is designed for a bar library building. 2) The slab is designed as a one-way slab with 10 numbers of 12mm diameter bars at 200mm c/c spacing in the shorter span to resist the factored bending moment of 21.38 kN-m. 3) 8 numbers of 8mm diameter bars at 240mm c/c spacing are provided in the longer span as minimum reinforcement along with shear reinforcement.

Uploaded by

Pronay Dhak
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 4

Design A simply supported slab for bar library building having clear span 4.57 m ×18.

28 m
is supported on two walls of 600M and 500M
Given Data,
Lx = 4.57 m, Ly= 18.28 m
18.28
∴ Ly/Lx = =4>2 Hence, the slab is one way slab
4.57
Assuming, live load = 0.75 Kn/m2 [For inaccessible roof ]
Fck = 25 N/mm2 and Fy = 500 N/mm2
Effective Depth of Slab
For simply supported slab, L/deff = 20 [ C.l n.o 23.2.1; IS 456:2000 ]
Assuming modification factor = 1.5
∴ L/deff =20 ×1.5 = 30
4570
∴ deff = L/30 = = 152.3
30
Let us adopting clear cover of 20 mm and using 10 ɸ HYSD bar.
∴ Overall depth, D = (152.3+20+5) = 177.3 mm
Let, we decrease the volume of overall depth of slab as 175 mm,
∴ deff = (175 – 20 – 5) = 150 mm.
Effective Span (Leff )
It should be least of the below –
0.6 0.5
I. Center to center spacing = (4.57 + + ) = 5.12
2 2
II. Clear span + Eff. Depth = (4.57 + 0.150) = 4.72
∴ Effective span of slab is 4.72 m
Load Calculation
For 1 m width of slab –
Self-weight of slab = (0.175 × 1 × 25) = 4.375 Kn/m
Live load = 0.75Kn/m
∴ Total load = (4.375 + 0.75) = 5.125 Kn/m
Factored load / Design load ,Wu = (5.125 ×1.5) = 7.68 Kn/m
Design Moment
W u × L2eff 7.68×( 4.72)2
Mu = = = 21.38 Kn/m
8 8
Check for Effective depth
X u max X
Mu lim = 0.36 × (1- 0.42× u max ) × b × d 2eff × Fck [G-1.1,C; IS 456:2000]
d d
X u max
21.38 ×10 6 = 0.36 × 0.46 (1- 0.42 × 0.46) 1000 × d 2eff ×25 [ for Fy = 500 , = 0.46 ]
d
∴ d required = 80.00 mm ¿ 150 mm = d provided [ Hence Ok ]
Area of Reinforcement
A st f y
∴ Mu = 0.87 × fy ×Ast × d ×(1 - ) [ G-1.1,b; IS 456:2000 ]
bd f ck
A st × 500
∴ 21.38 × 106 = 0.87 × 500 ×Ast ×150 (1- )
1000× 150× 25
Or, 327.66 = Ast – ( 1.33 ×10−4 ) A2st

Or, A2st – 7518.70 Ast + 2463609 = 0

7518.70± √(7518.70) −4 ×1 ×2463609


2
∴ Ast =
2
7518.70± 6832
∴ Ast =
2
7518.70−6832
∴ Ast = = 343.35 mm2 [Required]
2
π
∴ n× ×10 2 = 343.35 [ n = 4.37 ≈ 5 nos. ]
4
π
Now, Ast = 5× × 102 = 392.7 mm2 [ Provided ]
4
1000 ×a 1000× 78.53
Spacing of bars = = = 199.97 mm ≈ 200 mm
A st , provided 392.7
c
∴ Provide 10 ɸ bars @ 200 mm in shorter span.
c
Minimum reinforcement / Distribution bar for slab
Ast, min = 0.12 % of total cross-section area Agross
0.12
= ×1000 ×175 = 210 mm2 ¿ 392.7 mm2 [ Hence Ok ]
100
π
Using 8 mm dia bars = × 82 = 50.26 mm2
4
1000× a 1000× 50.26
Spacing = = = 239.3 mm ≈ 240 mm
A st , min 210
c
∴ Provide 8 ɸ bars @ 240 mm in longer span.
c
l 4720
Bending half the bars at 675 mm ( = =374 mm) from the centre of support.
2 7
Check for Shear
W u × L 7.68× 4.72
Vu = = = 18.12 Kn = 18120 N
2 2
Vu 18120
Normal shear stress, τ v = = = 0.12 N/mm2
bd 1000× 150
Design shear strength of concrete (τ c) –
392.7
At support Ast = =196.35 mm2
2
A st
Pt = 100 ×
bd
196.35
= 100× = 0.13 % which is less than 0.15 %
1000 ×150
For Pt ≤ 0.15 and M25 grade concrete τ c = 0.29 N/mm2 [ Table 19; IS 456:2000 ]
And, for M25 concrete grade, τ c, max = 3.1 N/mm2
∴ τ v ¿ τ c <¿ τ c, max [ Hence Ok ]
Check for Deflection
A st
Pt = 100×
bd
392.7
= 100× = 0.26 %
1000 ×150
f s= 0.58 × f y ( Area of steel required/ Area of steel provided ) [ Cl.–23.2.1; IS 456:2000]
343.35
= 0.58 × 500× = 253.55 N/mm2
392.7
For Pt = 0.26 % and f s253.55 N/mm2
Modification factor , k t= 1.6 [ Cl.- 23.2.1; IS 456:2000 ]
l
∴( d ) = 20 × k t = 20 × 1.6 = 32
max

l 4720
∴( d ) = = 31.44
provided 150

l l
∴ (d) <¿ ( )
d max [ Hence Ok ]
provided

Check for Development length [Cl.–26.2.3.3; IS 456:2000]


M 6
+ L0= 21.38× 10 + 0 = 1180 mm [ Using no hook ]
V 18120
0.87 × f y × ∅
Ld = For M25 grade concrete , τ bd = 1.4 [ Cl.–26.2.1.1; IS
4 τ bd
456:2000]
0.87 ×500 ×10
=
4 ×1.40
= 776.78 mm

M
Since, + L0 > L d
V
Therefore, Slab is safe.