02 - Create - ROC-3313
02 - Create - ROC-3313
manufacturer of Industrial
meter, Reverse Osmosis controller, Flow meter and Sensors. Our instruments could
be widely used in: Water treatment, Electronic power, chemical industry, Pharmacy,
Environment protection.
We have substantial market share in China, almost70%. Our instruments are popular,
not only in China, but also in International market. With strong scientific and
technical strength, our products have been exported to more than40 countries
covering Asia, Europe, American, Oceania, and Africa. Our instruments earn good
reputation in domestic and aboard market due to high quality and reasonable price.
inserting, installing, SMT, soldering and after making and facilities for measure,
serve customers and friends. We are doing every effort to thank good cooperation
and great support of many years from our customers with our continuous process,
circumspect service.
Honors:
conductivity
2004 Hi-tech Enterprise of Hebei Province and honor the Financing and Technical support.
2006 CE accreditation
SERIES OF Industrial Circulation Cooling Water Controller
DCK-6500 Industrial Circulation Cooling Water Controller
Features and application
The DCK-6500 is a kind of intelligent controller
for conductivity measurement and Chemicals
dosing of industrial circulation cooling water.
The meter is not only used for the Conductivity &
Temperature measurement of the Enclosed type
circulation cooling water systems and Opening type
systems , but also widely used for the adjustment
of water chemical dosing.
Be based on monitoring the conductivity value of
the industrial circulation cooling water to control
the concentration multiple of the cooling water, and
then drainge and water supplement in time. Control
the dosing According to the time proportion, the drainge, the water supplement to cuculate the dosing ,
which will protect the pipeline from corrsion , improve the heat exchange efficiency, reduce the energy
consumption.
The meter is widely used for the circulation cooling water system of Central Air-condictioning,Petroleum
Chemical Industry, Metallurgy, Thermo Power plants, Chemical fertilizer plant.
Conductivity over-limited warning; No reagent warning; circulationg water over temperaure warning
Multi-sensors conductivity measurement; strong ability of anti-pollution; large measurement range ; high
level accurate.
The double channels of the measurement will offer the data of water supplyment, drianage and so on.
Corrosion inhibitor, sterilizing agent will be dosing by timing.
The measurement data could be record for the paperless function.
Sensor:Pt1000
Water temperature Accurate:±0.5℃
Measurement range:0 ~ 56 ℃ (273~ 373K)
measurement
Resolution:0.1℃
Stability:±1℃/24h
Components of measurement:TDS sensor
Accurate:±2%
TDS measurement Measurement range:200 ~ 20000 ppm (mg/L)
Resolution:±1%
Stability:±2%/24h
Dosing solenoid control output: triplicat channels
Switching value Circulationg pumps control output: double channels
signal input Water supplement control output: one channel
Heat exchanger control output: on channel
Anoloy output 0~20mA isolated output(corresponding to the conductivity): one
channel ( capacity load≤500Ω)
Communiction port RS-485 serial port: one channel
port 240x160 LCD screen with background light; 6 pieces of press key
Working
Temperature :0 ~ 60 ℃; Humidity :≤90% RH
environment
Power supply
AC 220V±10% 50Hz; Power consumption:≤10W
Demension
235×185×119mm
Installatin
Wall hanging.
SERIES OF CONDUCTIVITY METER
DCK-8550 Conductivity Controller
Main features:
DCK-8550 Midlevel Intelligent Network Model industrial on-line conductivity controller is a top
grade meter used for continuous measuring and controlling of industrial flow water quality.
Main Technical Specifications:
Conductivity measurement range:
0.1cm-1: 0.00μS -400.0μS,
-1
1.0cm : 0.00μS -4000μS,
10cm-1 : 0μS -40.00ms
Temperature measure range: 0~50℃
Accuracy: 1.0 %( FS)
Stability: ±2×10-3(FS)/24h
Auxiliary electrode: 0.1cm-1, 1.0cm-1 or
10.0cm-1 and with the match of PT100 three
wires platinum resistance thermometer sensor
Operation pressure of conductance cell: 0~0.5 MPa
Medium temperature: 5~50℃
Temperature compensation: automatic compensation, with 25℃ as standard
Cable composition: RVP+ coaxial cable 75-2 (double shielding)
Cable length: 5m or on agreement _ m
Display mode: the conductivity value、 temperature、 time and date、operating status and current mA
values on the LCD (Liquid Crystal Display) screen at the same time
LCD back-light brightness: 5 levels to be selected
4~20mA output: active or passive output, isolated, adjustable, reversible 4~20mA output
Alarm output mode: open collector/ set electrode, light isolated output: the maximum value 300mA,
the maximum value of up-pull voltage 24VDC (direct current), high/low alarm with adjustable of
return.
Maximum speed of frequency output: 400pulses/minute, used for driving adding medicine pump
Environmental Condition: temperature: 0~50℃ ; humidity: ≤85% RH
Temperature compensation components: PT100 three wires platinum resistance thermometer sensor
Power supply: DC24V (±4V)
Outline dimension: 96 × 96 × 103mm (height × width × depth)
Slot dimension for installation: 91 × 91mm (height × width) Installation: Jam-in
DCK-8520 Series of Double Channels Intelligent Network Conductivity
Controller
Main features:
The double channels conductivity
monitor/controller can measure the value of
inflow water conductivity, outflow water
conductivity, desalination, current water
temperature, optional display double channel
resistivity, double channel TDS. 128×64 matrix
LCD display, English menu display, flexible
rubber key-press with good hand feeling, and also
with water-proof function. It is widely used for
power factory, chemicals, pharmacy,
environmental protection, metallurgy, paper
making, food and water supply etc.
Model 4-20mA Output mode Relay output Measurement range Range switch
DCK-4230 None-isolated Instrument mode No 0-20,0-200,0-2000 Manual
DCK-4231 No No Yes 0-20,0-200,0-2000 Manual and Automatic
DCK-4232 None-isolated Instrument mode Yes 0-20,0-200,0-2000 Manual and Automatic
Instrument and
DCK-4332 Isolated Yes 0-20,0-200,0-2000 Manual and Automatic
Transmitter mode
Main Technical Specifications
Conductivity Measuring range: 0~20、0~200、0~2000μS/cm(1.0cm-1 electrode)
0~200、0~2000μS/cm、0~20mS/cm (10.0cm-1 electrode)
(Three steps of ranges, selected through keyboard)
Temperature measuring range: 0~60℃
Accuracy: 1.5%(FS)
Stability: ±2×10-3(FS)/24h
Operation pressure of conductance cell: 0~0.5Mpa
Medium temperature: 5~50℃
Automatic temperature compensation: calculate compensation according to mathematic model , with
25 ℃ as standard condition (when the temperature compensation factor is zero, there is no
temperature compensation for measurement)
Power supply: AC 220V±10% 50Hz
Power consumption: ≤2W
Output current signal: isolated output 4~20mA, switchable between active and passive output
(ex-factory setting is active output)
Display mode: 3½ digits for conductivity, 3 digits for temperature
Contact capacity: 3A/250V AC (for resistive load)
Environment conditions: temperature: 0~50℃;humidity: ≤85%RH
Electrode configured: 1.0cm-1 plastic electrode
Screw thread size: 1/2"NPT (pipe thread)
Cable structure: RVP+ coaxial cable 75-2 (double shielding)
Cable length: normal 5m or specified as ______m
Outline dimensions:96×96×130 mm ( height×width×depth)
Slot dimension for installation: 91×91 mm ( height×width) Installation: Jam-in
DCK-3900 High-temperature Conductivity/Resistivity Double Windows
Controller
Performance features
Temperature + conductivity + resistivity controller. Electrode consistent check can be met by jam-in
Microchip. Conductivity/resistivity can be
displayed optionally.
Conductivity/resistivity and
temperature over limit alarm can be set
optionally. Conductivity/resistivity can
be displayed at the same time with
double-line LED digital canal. With
function of digit calculating
temperature compensation, it can preset
and modify compensation parameters.
Conductivity/resistivity at temperature
of 25℃ or 90℃ can be displayed
optionally. It is with features of
stability of high temperature and reliable long time operation.
Main Technical Specifications
Measuring range: Conductivity : 0~20μS/cm Resistivity : 0.05~18.25 MΩ·cm
Accuracy: 1.0%(FS)
Stability: ±2×10-3(FS)/24h
Auxiliary electrode: 0.1cm-1 High temperature sanitation 316 L stainless steel
Medium temperature: 70~150℃
Temperature compensation : Automatic temperature compensation: calculate compensation with 90℃
as standard condition
Power supply: AC 220V±10% 50Hz
Power consumption: ≤4W
Data connection port: RS485 port, Modbus agreement
Output current signal: isolated output 4~20mA, switchable between active and passive output
Maximum load impedance: 500Ω Max@ 24V DC
Display mode: Red LED digit double-window display
Contact capacity: 5A/250V AC (for resistive load)
Environment conditions: temperature: 0~50℃;humidity: ≤85%RH
Screw thread size: 1/2"NPT (pipe thread)
Cable structure: RVP+ coaxial cable 75-2 (double shielding)
Cable length: normal 5m or specified as ______m
working pressure of conductance cel:0~1.0MPa
Control output: ON/OFF double channels relay output.
Load capacity of the relay: AC230V/7A Max; AC115V/10A Max.
Auxiliary printer: WDJ-4680 paperless recorder+ printer
Dimensions:96 × 96 × 130mm (height × width × depth)
Slot dimensions for installation:91 × 91mm (height × width) Installation: Jam-in
CM-230(330)X Series Intelligent Conductivity Meter
Performance features
CM-230(330)X series intelligent on-line conductivity meter, it is the upgrade substitute meter of
CM230、CM-230SX 、330、
240、340.
It has keyboard setting electrode
constant , high、low limit alarm,
transferable 4 ~ 20mA current
signal output , checking the
media temperature、μS/cm and
ppm (TDS)conversion through
the switching keys,automatic range conversion,three types of constant to be chosen
(0.1cm-1、1.0 cm-1、10.0 cm-1),larger measurement range.
It has ultra steady measurement collecting,large temperature range、low excursion design,can
switch conductivity/ temperature/TDS under the measurement condition,can give an alarm when the
water quality is over standard,high brightness back-light LCD display.
It is used for on-line monitoring and controlling of reverse osmosis 、electrodialysis、ion exchange
producing water system、cooling water control system and industrial water..
Model and performance function:
Non-isolated Automatic Hi/Lo
4mA signal measurement Hi-limited limited Units of the Probe
Function/model output range alarm setting alarm setting measurement Constant
CM-230A ● ● ● ●
CM-230C ● ● ● ●
CM-230D ● ● ● ● ●
CM-330C ● ● ● ●
Main technical specification:
Measurement range:
Conductivity: 0~19.99 0~199.9μS/cm (0.1cm-1 electrode)
0~19.99 0~199.9、0~1999μS/cm (1.0 cm-1 electrode)
0~199.9μS/cm 0~1999μS/cm 0~19.99mS/cm (10cm-1 electrode)
Temperature: 0-50℃
Auxiliary electrode:
1.00cm-1 plastic platinum gold electrode,1/2″(1/2 inch)pipe screw connection;
1.00cm-1 stainless steel electrode,1/2″(1/2 inch)pipe screw connection;
10.0 cm-1 Teflon platinum electrode,3/4″(3/4 inch)pipe screw connection;
The length of the cable:5m as ex work standard figure or according to the user’s specification;
Medium pressure:0~0.5MPa;
Medium temperature:0~50℃;
Component of temperature compensation:NTC;
Display mode:conductivity:3.5-bits LCD Digit display,temperature: 3- bits Digit display;
Accuracy:1.5%(FS)
Stability:±2×10-3(FS)/24h;
Temperature compensation : Digit calculating compensation , with 25 ℃ as the reference
temperature;
Output signal :non- isolated,transferable 4~20mAcurrent;
Maximum load impedance :300Ω Max@ DC 9V ;
Relay load capacity:AC 230V/5A Max (without electromagnetic induction);
Output control model:ON/OFF two contacts relay output;
Power supply :AC 220V±10%,50Hz;
Power consumption:2W
Environment conditions:Temperature:0~50℃; Humidity:≤85%RH;
Outline dimension:48×96×100mm(height×width×depth)
Slot dimension for installation:45×91mm(height×width)
Installation: Jam-in
CM-230 Conductivity Monitor
Performance features
This instrument is a panel instrument for
on-line monitoring of industrial process
conductivity. Range switch over and constant
check can both be freely set and adjusted
through the operation component on the rear
panel; unique signal collecting and processing
technology and special thick film circuit are
adopted to make measurement accurate and
operation stable; there are also other features such as linearzed data, automatic temperature
compensation, not subject to the length change of cable and maintenance-free. It’s an ideal auxiliary
instrument of various types of small pure water equipment.
Main technical specifications
Measurement range: 0~20 0~200 0~2000μS/cm
Accuracy 1.5% (FS)
Stability ±2 × 10-3 (FS) / 24h
Auxiliary electrode Plastic structure; constant: 1.0cm-1
Temperature compensation NTC
Medium temperature 5~50℃
Output signal Non-isolated 4-20mA signal output
Maximum load impedance 300Ω Max@ 24V DC, instrument mode
Thread dimension 1/2〃pipe thread
Medium pressure 0~0.5Mpa
Cable composition RVP + coaxial 75-2 double shielding
Cable length 5m or on other agreement (5~30m)
Temperature compensation Automatic compensation, with 25℃ as the reference temperature
Display Back light 3.5-bit LCD
Power supply AC 220V ±10% 50Hz
Power consumption ≤1W
Environment conditions Temperature: 5~50℃ ;Humidity: ≤85%RH
Dimensions 48 × 96 × 100mm (height × width × depth)
Slot dimensions for 45 × 91mm (height × width)
Installation Jam –in
CM-230SX Hi/Lo Limited Conductivity Controller
Performance features
This instrument is a panel instrument for
online monitoring of industrial process
conductivity. The measurement range and
constant has been set by original
manufacturer. It can be set alarm for high or
low limit of conductivity .It has automatic
temperature compensation with 25℃ as
reference temperature. It features stable
operation and accurate measurement. And it
is widely used in online monitoring of water quality for electrodialysis, reverse osmosis
system and common pure water producing system. It’s an ideal auxiliary instrument of various types
of small pure water equipment.
Main technical specifications
Measurement range: 0~20μS/cm,0~200μS/cm,0~2000μS/cm (Fixed range which has been set
by the manufacturer can not be changed by customers: So please indicate which measure range will
be needed before placing an order)
Accuracy:1.5% (FS)
Stability:±2 × 10-3(FS) / 24h
Auxiliary electrode: Plastic structure; constant: 1.0cm-1
Temperature compensation component: NTC
Medium temperature:5~50℃
Control output mode: ON/OFF relay output
Relay load capacity: AC 230V/7A Max ; AC 115V/10A Max
Thread dimension:1/2″pipe thread
Medium pressure:0~0.5Mpa
Cable composition: RVP + coaxial 75-2 double shielding
Cable length:5m or on other agreement (5~30m)
Temperature compensation: Automatic compensation, with 25℃ as the reference temperature
Display:3.5-bit LCD
Power supply: AC 220V ±10% 50Hz
Power consumption:≤1W
Environment conditions: Temperature: 5~50℃;Humidity: ≤85%RH
Dimensions:48 × 96 × 100mm (height × width × depth)
Slot dimensions for installation:45 × 91mm (height × width)
Installation: Jam-in
CM-232 Double Channels Conductivity Monitor
Performance features
This instrument is a panel
instrument for on-line
monitoring of industrial
process conductivity.
Measurement range and
constant check have been
adjusted by manufacturer.
Easy installation and
operation, accurate
measurement and stable operation. There are also other features such as linearized data, automatic
temperature compensation, not subject to the length change of cable and maintenance-free. It’s an
ideal auxiliary instrument of various types of small pure water equipment.
Performance features
This instrument is a panel instrument
for on-line monitoring of industrial
process conductivity. Range switch
over and constant check can both be
freely set and adjusted through the
operation component on the rear
panel; unique signal collecting and
processing technology and special
thick film circuit are adopted to
make measurement accurate and operation stable; there are also other features such as linearized data,
automatic temperature compensation, not subject to the length change of cable and maintenance-free.
It’s an ideal auxiliary instrument of various types of small pure water equipment.
Main technical specifications
Measurement range: 0~20 0~200 0~2000μS/cm
Accuracy:1.5% (FS)
Stability:±2 × 10-3 (FS) / 24h
Auxiliary electrode: Plastic structure; constant: 1.0cm-1
Temperature compensation component: NTC
Medium temperature:5~50℃
Output signal: Non-isolated 4-20mA signal output
Maximum load impedance:300Ω Max@ 24V DC, instrument mode
Thread dimension:1/2〃pipe thread
Medium pressure:0~0.5Mpa
Cable composition: RVP + coaxial 75-2 double shield
Cable length:5m or on other agreement (5~30m)
Temperature compensation: Automatic compensation, with 25℃ as the reference temperature
Display:3.5-bit Red LED
Power supply: AC 220V ±10% 50Hz
Power consumption:≤1W
Environment conditions: Temperature: 5~50℃ ;Humidity: ≤85%RH
Dimensions:48 × 96 × 100mm (height × width × depth)
Slot dimensions for installation:45 × 91mm (height × width)
Installation: Jam-in
CM-330 Conductivity Controller
Performance features
This instrument is a panel instrument
for on-line monitoring of industrial
process conductivity. Range switch
over and constant check can both be
freely set and adjusted through the
operation component on the rear panel;
unique signal collecting and processing
technology and special thick film
circuit are adopted to make
measurement accurate and operation stable; there are also other features such as linearized data,
automatic temperature compensation, not subject to the length change of cable and maintenance-free.
It has control function, including setting of over limit of conductivity, and the outputs are control
contacts. It’s an ideal auxiliary instrument of various types of small pure water equipment.
Main technical specifications
Measurement range:0~20, 0~200, 0~2000 (μS/cm) optional
Accuracy:1.5% (FS)
Stability:±2 × 10-3 (FS) / 24h
Auxiliary electrode:1.0cm-1 plastic electrode
Temperature compensation component: NTC
Medium temperature:5~50℃
Thread dimension:1/2〃pipe thread
Medium pressure:0~0.5Mpa
Cable composition: RVP + coaxial 75-2 double shield
Cable length:5m or on other agreement (5~30m)
Temperature compensation: Automatic compensation, with 25℃ as the reference temperature
Display:3.5-bit LCD
Control output mode: ON/OFF relay output
Relay load capacity: AC 230V/7A Max ; AC115V/10A Max
Power supply: AC 220V ±10% 50Hz
Power consumption:≤1W
Environment conditions: Temperature: 0~50℃ ;Relative humidity: ≤85%
Dimensions:48 × 96 × 100mm (height × width × depth)
Slot dimensions for installation:45 × 91mm (height × width)
Installation: Jam-in
CM-330D Conductivity Controller
Performance features
This instrument is a panel instrument for
on-line monitoring of industrial process
conductivity. Range switch over and
constant check can both be freely set and
adjusted through the operation component
on the rear panel; unique signal collecting
and processing technology and special thick
film circuit are adopted to make
measurement accurate and operation stable; there are also other features such as linearized data,
automatic temperature compensation, not subject to the length change of cable and maintenance-free.
It has control function, including setting of over limit of conductivity, and the outputs are control
contacts. It’s an ideal auxiliary instrument of various types of small pure water equipment.
Installation Jam-in
DDY-2327 Portable Conductivity Monitor
Performance features
This instrument is suitable for conductivity measurement of
outdoors. Multi-purpose software is adopted to make
measurement accurate and performance stable. It features
with such as floating digit, direct reading, and automatic
measurement range and temperature measurement.
Temperature accuracy:0.5℃
Medium temperature:0~50℃
Display:3.5-bit LCD
Dimensions:150 × 70 × 25mm
Features
DRK-7461 is an instrument for online monitoring and
exchange bed.
Stability: ±2×10-3(FS)/24h
Signal output: Analog signal 4~20mA (load characteristics :500Ω Max@24V DC)
Alarm Mode: resistivity low limit alarm and setting of action backlash can avoid critical shake
Installation: Jam-in
DRK-7561 Resistivity Controller
Features
It is an instrument for online measuring and controlling
conductivity/resistivity of Industrial process water quality.
With jam-in microchip it has functions of electrode
constant input ,check ,setting of resistivity high limit
alarm and control through keyboard .It is widely used for
comparing and monitoring the quality change before
treatment and after treatment of EDI , anion-cation
exchange bed and two grade reverse osmosis.
Features
DRK-4000 series controllers are the kind of
intelligent industry on-line controllers. There is a
flush type CMOS chip inside the controller for
resistivity controlling, so the controller is rich of the
software function. The controller could be set and
controlled the Resistivity low-limited alarm; switch
over the value of conductivity and resistivity;
insulated transferable 4-20 MA current signal output;
work as controller / transformer; work with the PLC
/ servo system conveniently ; Connect with all the 4-20 MA current signal output
systems.
Due to the nice appearance and the friendly operation mode, the DRK-4000 controller
has special features.
The controller has different kinds of the functions, competitive price and excellent
performance; all these can meet the requirements of different level users.
The controller can widely used in the measurement of EDI, Ion exchange, Hi-pure water,
Ultra water…
Technical Specification
Measurement Range: Resistivity: 0~18.25MΩ·cm Conductivity: 0.050~2.0μS/cm
Accurate: 2.0 %( FS)
Stability: ±2×10-3(FS)/24h
Auxiliary Electrode: constant 0.05cm-1; sanitary 316L stainless steel titanium cylindrical
electrode
Medium temperature: 5~50℃
Temperature compensation : Automatic compensation, with 25℃ as standard condition
Display mode: LCD digit double windows display, Resistivity/Conductivity: 3.5bit,
(the conductivity value could be display transiently)
Contact point mode: ON/OFF, 5A/250V AC
Environment conditions: (1) temperature: 0~50℃ (2)humidity ≤85%RH
Power supply: AC 220V±10% 50Hz
Power spend: ≤3W
Outline dimensions: 96×96×130mm (height × width × depth)
Instrument panel hole: 92×92mm (height × width)
Installation: Jam-in
Technical Sheet
DRK-4220 ● ● ● ●
DRK-4220A ● ● ●
DRK-4220C ●
RM-220/320 CRM-420 CRC-520 Resistivity Monitor/Controller
Performance features
The instruments of this series are on-line panel-mode
ensure long term and stable operation. It also has some optional functions such as control, alarm,
conductance/resistance.
Type
Option RM-220 RM-320 CRM-420 CRC-520
function
Control, alarm × √ × √
4-20mA output √ × √ ×
Switching display between
× × √ √
conductance/resistance
Reverse Osmosis collection point: Raw water no water protection, High pressure full water
protection,Operation reposition.
Reverse Osmosis control point: High pressure pump, Cycle pump, Flush valve, RO outlet
valve,Disinfection valve, Disinfection discharge valve, DI pure water outlet valve, Internal cycle
valve.
Power supply: DC24V (a power switch should be installed before designing the shell)
Power consumption: ≤7.2W
Environmental condition: 1) temperature: 0~60℃; 2) humidity: ≤ 85% RH.
Accuracy: 1.5 level
Output contact capacity load: 5A/250V AC 3A/24V DC
Updating rate of collecting result: ≤1sec/per time
Working pressure of conductance cell: 0~0.2Mpa
Automatic temperature compensation: 1~49℃
Interface mode: LCD display, English/sign display, touch key
Measurement range
TDS1 Raw water conductivity : 0-1000 ppm (auxiliary electrode 1.0 cm-1 )
TDS2 RO produce water conductivity: 0-100 ppm(auxiliary electrode 1.0cm-1)
DI produce water resistivity: 0-18.2 MΩ·cm (auxiliary electrode 0.05cm-1)
Return when over-time limit key. Under normal operation, not in the main interface, if there is no
any key were pressed within 2 minutes, it will come back to the main menu automatically .
Outline dimension: 90 × 150 × 46mm (height × width × depth)
Slot dimension: 57 × 106mm (height × width)
Installation: Panel
ROC-4313 Two stage reverse
Performance Features
The instrument is combination of two stage
reverse osmosis controller and on-line
conductivity monitor. It is a special-purpose
measurement and control system. This system
has the functions of automatic test, operation
test, status control, display, letter hint, indicating light display etc. The controller
aggregates all the advantages of PLC controller and the meter for measuring water quality.
Main technical indexes
Raw water tank level, middle tank level, no water
protection, handle/automatic control, first stage
Reverse osmosis collecting point pressurization pump low/high pressure protection, second
stage pressurization pump high pressure protection, and so
on.
direct current power supply, pull electrical digit, all
Collecting input signal
terminals are isolated .
feed water pump, first-grade pressurization pump,
second-grade pressurization pump, inlet water valve,
Reverse osmosis controlling point
pretreatment valve, flushing valve, first-grade over-limit
outflow valve, second-grade over-limit outflow valve.
raw water conductivity collect ,first-stage outlet water
Measuring collection point conductivity collect, and second-stage outlet water as well
as temperature collection .
Raw water conductivity 0 ~ 20mS/cm 、 0 ~
2000μS/cm(match 10cm-1 or 1.0cm-1 electrode) first-stage
Measuring range reverse osmosis conductivity 0~200μS/cm(match 1.0 cm-1
electrode) second-stage reverse osmosis conductivity 0~
20μS/cm(match 0.1cm-1 electrode)
Power supply voltage 24V DC (switch should be installed outside when designing)
Accuracy 1.5 level
Output control mode ON single contactor output
Load capacity of output contact 5A/250V AC 3A/24V DC
Rate of renewal of connecting ≤1second\time
Operation pressure of conductance 0~0.5Mpa
Temperature compensation automatic temperature with 25℃ as reference temperature
Outline dimensions 130×180×60mm(height ×width ×depth)
Slot dimension for installation 122×172mm (height× width)
Installation control plate panel
ROC-3313 Reverse Osmosis Controller
Performance Features
The instrument is a combined control
instrument of a reverse osmosis controller and
an on-line conductivity instrument. It can
perform the operation test, status control and
on-line monitoring of water quality
conductivity (combining PLC controller and
conductivity meter). It takes multiple
anti-interference measures, adopts unique
process flow and graphical control panel with
LED indicator lamp embedded, the interface is
friendly; menu-driven operation is used, multiple groups of parameters can be set and modified, the
requirements of automatic operation are met.
Function 2 channels
U disk Communication
Pulse input 4-20mA output OC door
connection connection
Model output
WLG-8350 ● ● ●
WLG-8351 ● ● ● ●
WLG-8352 ● ● ● ●
WLG-8353 ● ● ● ● ●
Input
Instantaneous value range: -9999~9999 radix point position could be set
Cumulation value range: 0~99999999
radix point position could be set
Resolution: 1/20000 Instantaneous value
Input signal type: pulse
Pulse: 0.1~150 KHz
Basic error: Less than ±0.2%F.S
Controlling period of measuring: 0.2
second
Record
Record capacity:4MB
Record interval:1second ~59 minutes 59 seconds could be selected. Cycle record or full record
suspends could be chose.
Record time:The computational formula between the record time and record interval :
Record days = (record capacity × record interval )/(24×3600)
72 hours is the shortest time record; 29 years is the longest time record.
Record content: instantaneous value
Alarm
Alarm output: instantaneous flow Hi-lo limited alarm mode and cumulative volume preset output.
OC door output ,voltage less than 30V, current less than 50mA
Transmit
isolated output
4mA~20mA,0mA~10mA,0mA~20mA DC current output, could be selected by setting . The
resistivity load is more than 600Ω. DC current output, select through setting. Load capacity should
larger than 600Ω
Performance Features:
pH/ORP-8150 is a single/double channels pH/ORP meter, the
pH/ORP value of channel 1 or 2 can be displayed by single
channel, double-channel parameters can be also displayed
Simultaneously; Main parameters, temperature and mA
output value could be displayed on the screen synchronously,
the temperature compensation can be set as manual or
automatic mode.
This product is widely used for chemicals, pharmacy,
environmental protection, metallurgy, power factory, paper
making, food and water supply etc.
0~14 pH
pH measurement range
resolution 0.01 pH
accuracy ± 0.05 pH
accuracy ± 2 mV
accuracy ± 0.1℃
Display mode: with backlight 128×64
Control output: high limit, low limit double
lattice LCD display
rode ON/OFF double contact point output.
The range of automatic temperature
Capacity of contact point: AC230V/5A Max;
compensation: 0~99.9℃
AC 115V/10A Max
Stability: pH≤0.05pH/24H, ORP≤2mV/24h,
Communication: RS485 output
T≤0.2℃/24h
4~20mA current output: isolated, transferable,
≤0.03mA/24h
reverse, optional meter/transmitter output.
Identify automatically pH buffer and three
The maximum load impedance: 500 Ω
point calibration.
Max@24V DC
pH standard liquid: 4.01, 6.86, 9.18.
Power supply: AC 220V±10% 50Hz
ORP standard liquid: any
Environment conditions: humidity: ≤
Input impedance: >1.5×1012
85%/RH; no strong electro-magnetic field
Electrode pressure resistance: 0~0.6 MPa
interference except earth magnetic field
Measuring distance: ≤ 20m(standard
Outline dimensions: 96×96×130mm (height
configuration for electrode cable:5m).Please
×width×depth)
use pH transducer for overlong range.
Slot dimension for installation: 91×91mm
Control range: 0~14pH ; -1999mV~+1999
Installation: Jam-in
mV
pH/ORP-4571 pH/ORP Controller
Performance Features:
pH/ORP-4571 is on-line intelligent industrial pH (ORP)
controller. The instrument is suitable for online monitoring of
pH/ORP in water treatment, electronic power, chemical
industry, pharmacy, environment protection, breeding industry,
and so on.
Performance Features:
pH/ORP-6241 controller is an industrial on-line analysis and monitoring instrument, with 51 series
Single Chip Microcomputer (SCM) and
CMOS interface chip adopted. It’s with various
software functions, and has such features as
easy installation and operation, strong
anti-interference capability and little amount of
maintenance work. High-accuracy temperature
compensation is also adopted. The pH -6241 is
suitable for environmental protection and
on-line measurement; the ORP-6241 is widely
used in OPR measurement of Water treatment,
electronics industry, pharmacy, chemical,
environment-protection…
Performance Features:
pH/ORP-542 meter is an industrial
on-line analysis and monitoring
instrument. It’s with various software
functions, and has such features as easy
installation and operation, strong
anti-interference capability and little
amount of maintenance work.
High-accuracy temperature
compensation and pH operation
compensation is also adopted.
Functions
pH or ORP can be selected through menu.
Back ground LCD digital display.
Direct reading and accurate control with Micro chip for data processing
Automatic or manual three-point calibration, which improves the measurement accuracy of the
instrument.
4~20mA current output for long-distance transmitting.
It can optionally display pH mV value.
Strong anti-interference capability and automatically reset in case of power off.
Performance Features:
Welcome to use pH-5431 isolated pH transmitter. It apply to pH signal collect of long distance and pH
signal output , the direct output standard current signal is 4~20mA.
It’s with various software functions, and has such features as easy installation and operation, strong
anti-interference capability and little amount of
maintenance work. High-accuracy temperature
compensation and pH operation compensation is
also adopted.
Functions and Main Technical
Specifications
Functions
Back ground LCD digital display.
Direct reading and accurate control with
Micro chip for data processing
Automatic or manual three-point calibration, which improves the measurement accuracy of the
instrument.
4~20 mA current output is isolate, transferable, reversal, and can switch output mode of the
meter and transmitter.
It has functions of menu input and operation error compensation.
It can optionally display pH, mV value.
It has strong anti-interference and automatically breaks away the power.
It has the proof –water panel and operation keyboard.
Main Technical Specifications
pH measurement range :0~14 pH
Resolution: 0.01 pH
Accuracy : ±0.1 pH
Electrode pressure resistance: 0~0.6Mpa
Display: 3.5 bit LCD digit display
Distance limit of electrode cable: ≤20m (standard configuration for electrode cable: 10m). The
maximum load impedance: 500Ω Max @ DC24V
Temperature of measured solution: 0~99℃
Manual temperature compensation: 0~99℃
Environment conditions: temperature:0~50℃, humidity: ≤85%/RH; no strong electro-magnetic field
interference except earth magnetic field
Power supply : DC 24V±10%
mA output: isolate, transferable, reversal 4~20 mA current, the switch output mode of meter and
transmitter.
Outline dimensions: 130×70×50mm (height×width×depth)
Installation: Pipe or plane installation
CT-121Conductivity Transmitter
Performance Features:
Conductivity Transmitter CT-121 is designed with one-piece
and hermetic, as a PLC controller and primary instrument of
monitor and controller, the transmitter has characters of
water-proof, damp-proof and installed directly at scene,
anti-interference, easy installation and good weatherability
etc.
Specifications
Sealed, water-proof, one-piece design, fix settings
included.
Double line transmission, non-polarity
connection(automatic identification of the polarity)
Surface SMT technology
4~20mA standard current signal;
DC24V power supply
316L/Ti metal electrode
Automatic temperature compensation
Technical parameters:
Measure range: 0~20;0~200;0~2000μS/cm
Accuracy: ±1.5%(FS) of the readings
Shell: epitheca: ASA; Lower casing: nylon
Electrode: electrode:316L
Weight: about 200g
Operation environment: 0~50℃
Storage temperature: -15~60℃
Relative humidity: 0~100%RH
Current output: 4~20mA, in series
Power: DC 24V±5%
Maximum circle resistance: 24V@600Ω
Accuracy/precision: ±0.3mA@25℃
Installation: pipe installation
DBY-5100/5200 Conductivity Transmitter
Performance features
5100 is an integration mode conductivity transmitter.
5200 is a fission mode conductivity transmitter. They can
meet long distance measurement of water solution
conductivity in the industrial processes. The all sealed
shell design meet the IP65 defending technology grade ,
can adapt to the wet environment .The any transferable
4~20mA isolated current sgnal can realize the operation
mode of meter/transmitter by change the connection
mode.
Technical Specification
Conductivity measurement range:
Electrode constant 0.1cm-1 : 0~20 μS/cm, 0~200 μS/cm
(optional)
Electrode constant 1.0cm-1 : 0~20 μS/cm, 0~200 μ S/cm 0~2000 μS/cm (optional)
Electrode constant 10.0cm-1 : 0~200 μS/cm, 0~2000 μS/cm 0~20 mS/cm (optional)
Temperature measurement range :0~50℃
Accuracy:1.5%(FS)
Stability: ±2×10-3 (FS)/24h
Signal output : isolate , transferable 4~20mA current ,
the optional output mode of meter/transmitter
Power supply: DC 24V±10%
Temperature of measured solution: 5~50℃
Defending types :IP65 defending grade
The max circulative resistance : DC 24V@600Ω
Display mode : Conductivity : 3.5bit LCD digital
display , Temperature : 3bit digital display
Outline dimensions: 130×70×50mm (height×width×depth)
Installation mode: pipeline installation(5100), plane installation(5200).
DBY-5600 Explosion-proof Conductivity Transmitter
Performance features
The conductivity transmitter can meet Inflammable,
explosive gas ‘s industrial environment design. With the
transferable 4~20mA isolated current signals, can change
the connection mode which realize meter /transmitter’s
operation mode .
It uses the micro processor to control the intelligent
operation. It’s with various software functions, and has
such features as choosing electrode mode, switch
measurement range, constant calibration, and
temperature compensation.
Technical Specification:
Conductivity measurement range:
Electrode constant 0.1cm-1 : 0~20 μS/cm, 0~200 μS/cm (optional)
Electrode constant 1.0cm-1 : 0~20 μS/cm, 0~200 μ S/cm ,0~2000 μS/cm (optional)
Electrode constant 10cm-1 : 0~200 μS/cm, 0~2000 μS/cm, 0~20 mS/cm (optional)
Accuracy :1.5%(FS)
Stability: ±2×10-3 (FS)/24h
Power supply: DC 24V±10%
Temperature of measured solution: 5~50℃
Environment conditions: Temperature :5~50℃
humidity:≤85%RH;
The max circulative resistance : DC 24V@600Ω
Display mode : Conductivity 3.5bit LED digital display ,
The signal output: Isolated, transferable current 4~20mA , optional output mode of meter and
transmitter.
Defending type : Exd ⅡcCT6 defending grade
Installation: jam-in or fission
HL-360 Loop Meter
Performance and applications:
The instrument can display and control the industrial process conductivity transmitter, resistivity
transmitter and pH transmitter; it has
functions of conductivity, resistivity, pH
value displaying, over limit alarm,
control output etc. This meter also can
be used as the second instrument for
displaying conductivity, resistivity, and
pH value. Double line mode 4-20mA
standard current transfer, and advanced
anti-interference capability were
adopted.
This instrument meets the needs of long-distance measure, display and control operation between the
control room and the industrial place.
Features: ABS fast installation, screw thread, Pipeline installation and side
installation on the tank
Performance:
Electrode type: two sensor system.
Material: engineering plastic framework, stainless steel underlay with platinum
black
Temperature compensation components: NTC 10KΩ
Connection: 1/2″NPT (ABS fast installation)
Pressure: 0.5 MPa
Medium temperature: 0-50 ℃
Coil out:outgoing cable directly
Cable Length: 5 meters long Ex-factory or made by requirement
DCG1121-1.0~0.01cm-1 Electrode
Performance:
Electrode type: Two sensor system
Material: 316 L Stain Steel
Temperature compensation components: NTC 10KΩor Pt100/1000
Connection: 1/2″NPT (ABS fast installation)
Pressure: 0.5 MPa
Medium temperature: 0-50 ℃
Cable Length: 5 meters long Ex-factory or made by requirement
Features:
316 L Stain Steel, corrosion proof, long-time using
Specification:
Electrode constant: 1.0 、0.1、0.05 、0.01cm-1
DCT1121-0.1~0.01cm-1 Electrode
Performance:
Electrode type: two sensor system
Material: titanium metal
Temperature compensation components: NTC 10K or Pt100/1000
Connection: 1/2″NPT (ABS fast installation)
Pressure: 0.5 MPa
Medium temperature: 0-50 ℃
Coil out:outgoing cable directly
Cable Length: 5 meters long Ex-factory or made by requirement
DCT3121-1.0~0.01cm-1 Electrode
Electrode type: 316 L Stain Steel, corrosion resistance, long useful life
Performance:
Performance:
Electrode type: two sensor system
Material: 316 L Stain Steel
Temperature compensation components: NTC 10K or Pt100/1000
Connection: 1/2″NPT, Stain steel cube.
Pressure: 0.5 MPa
Medium temperature: 60~120 ℃
Coil out:outgoing cable directly
Cable Length: 5 meters long Ex-factory or made by requirement
DCS0120-1.0cm-1 Electrode
Usage: Conductivity measurement of weak electrolyte, include industrial
water, cooling water, tap water, pure water etc.
Performance:
Electrode mode: Two sensor system
Material: Plastic shell, stainless steel underlay with platinum black
Temperature compensation components: NTC 10KΩ
Medium temperature: 0-50 ℃
Coil out:outgoing cable directly
Cable Length: 5 meters long Ex-factory or made by requirement
DCG-7121 Microminiature Integration Conductivity
Sensor for Ultra Pure water
Usage
Be widely used in the Power House, Chemistry, Medicine Making,
Environment Protection, Paper Making, Food, Water Supply…
Technical Features
Design in the integration
Made by 316L S.S
Effective measurement space, no backwater or dead angle,
improve the measure accuracy.
Smaller size and convenient connection.
Usage
alkali …
Material: 316 L Stain Steel, Teflon, corrosion resistance, long useful life
Usage
Petroleum, chemistry, metallurgy, water supply, paper making, industry
cooling system, water treatment system…
Technical parameter:
Material: ABS plastic
Measurement: tangential measurement
Medium temperature: 0-60 ℃
Storage temperature:-20 ~80 ℃
Pressure: 0.6 MPa
Power supply: 12 V DC
Pulse output: ≥ 8V
Transmit distance: ≥ 1000 M
Pipe diameter: DN-25 ~ DN 200
Pipe material: plastic, metal, glass fiber reinforced plastic, cement.
Environment: There is no strong alternative magnetic field around the
electrode.
Medium requirement: Install the Y filter when there is some granule exists in the pipeline.
PC202 Plastic pH Combination Electrode
Range:0-14pH Temperature:0-100℃
Pressure:0.6MPa Process connection:Top & bottom 3/4 inch NPT, threads
Material:PPS Cable connection:connected by low noise cable directly
Characteristics:
Adopt the most advanced solid electrolyte and Tetrafluoroethlene liquid junction which resist to be
blocked and maintenance conveniently.
Long distance diffusion path of reference solution extended the useful life under the harsh conditions.
Wider temperature range can be used in explosion-protection area.
New design of glass bulb, increase surface area of it and prevent inner buffer solution from interfere of
air bulb to gain reliable measurement.
Adopt PPS body, top/bottom 3/4 inch threads that easy to be installed and no housing needed, saving
the cost of installation.
Use high quality low noise cable, the distance of output signals is longer than 20 meters without
disturbance.
Application area:
Medicine, chlorine-alkali chemical-engineering, paint & dye, paper making, intermediate, fertilizer,
starch, environment-protection… ; temperature fluctuation less than 10℃.
PCORP Plastic ORP Combination Electrode
Application area:
Be used for the ORP testing of Medicine, chlorine-alkali chemical-engineering, paint & dye, paper
making, intermediate, fertilizer, starch, environment-protection…
G102 pH Combination Electrode
Characteristics:
Apply big area low impedance sensitive membrane bulb, suitable for pure water application.
Apply gel type electrolyte, solid bridge electrolyte. Electrophoresis cell consists of two different kinds of
gel electrolytes, make sure longer working life of the electrode and reliable readings.
International standard connection, can replace imported electrodes directly.
Application area:
Water treatment, pure water industry.
——CREATE