Transformer protection RET650

Relion® 650 series Ver. 1.3

Features
• Fully IEC 61850 compliant
• Parallel Redundancy Protocol (PRP) according to IEC
62439-3 Ed.2
• Protection, control and monitoring integrated in one IED
• Extensive self-supervision including analog channels
• Four independent parameter setting groups
• Large HMI for visualization of single line diagrams and
on‑line measurements
• Ethernet interface for fast and easy communication with
PC
• Accurate time-synchronization via SNTP, DNP 3.0, IEC
60870-5-103 and IRIG-B serial interface
• Signal matrix for easy configuration of binary and analog
signals
• User management and authority handling
• Activity logging
• Available in customized and configured solutions

Configured solutions
• Two winding transformer in single breaker arrangements −− Four step residual non-directional/directional
• Three winding transformer in single breaker arrangements overcurrent protection with definite and inverse time
• Voltage control for two parallel transformers characteristics and with voltage, current or dual
polarization, based on zero sequence or negative
Most important protection functions sequence quantities with 2nd harmonic blocking
• Transformer differential protection −− Negative sequence directional overcurrent protection
−− Percentage bias restraint −− Broken conductor check
−− Waveform and second harmonic restraint for −− Thermal overload protection
transformer inrush −− Breaker failure protection
−− Fifth harmonic restraint for overexcitation −− Pole discordance protection
−− Automatic CT ratio matching and vector group • Power functions
compensation −− Directional under- and overpower protection
−− High sensitivity for interturn faults • Voltage
• Low impedance restricted earth-fault protection −− Two step phase- and residual overvoltage protection
−− Extremely fast operation with definite and inverse time characteristics
• Current −− Two step undervoltage protection with definite and
−− Instantaneous phase overcurrent protection inverse time characteristics
−− Instantaneous residual overcurrent protection −− Overexcitation protection
−− Four step directional phase overcurrent protection −− Loss of voltage check
with definite and inverse time characteristics with 2nd • Secondary system supervision
harmonic blocking −− Fuse failure supervision
−− Breaker close/trip circuit monitoring
• Frequency protection
−− Under- and overfrequency protection
−− Rate-of-change frequency protection
Control functions Hardware
• Voltage control for single or two parallel transformers • 1/1 x 19” width, 3U height case
• Automatic voltage control for two parallel transformers • 10-20 analog inputs depending on the configured
based on the minimum circulating current principle or solution
master-follower principle up to a maximum of four in the • Universal 1A/5A CT inputs
parallel group • Choice of communication and processor module with
• Selectable operator place allocation −− 12 binary inputs, TCP/IP optical, IRIG-B, galvanic
• Control of up to four circuit breakers from local/remote RS485 and optical serial communication ports
• Versatile switch with two positions −− TCP/IP optical with PRP redundancy, IRIG-B, galvanic
• Selector switch with up to 32 positions RS485 and optical serial communication ports
• Binary input/output modules with 9 inputs and 9 outputs

1MRK500111-SEN 10/2013
Logic • Possibility to add two optional binary input/output
• Tripping logic modules (configured solutions for two winding
• Trip matrix logic transformer in single breaker arrangements and voltage
• Configurable logic blocks control for two parallel transformers)
• Configurable logic blocks with quality and time • I/Os customizable to
−− 10 analog inputs (selected combinations of CT/VT
Monitoring inputs) and up to four binary input/output modules
• Disturbance recorder −− 20 analog inputs (selected combinations of CT/VT
−− 100 disturbances inputs) and up to two binary input/output modules
−− 40 analog channels (30 physical and 10 derived) • Power supply modules from 24 to 30 V DC, 48 to 250 V
−− 96 binary channels DC or 100 to 240 V AC with 9 outputs, 3 of which with
• Event list for 1000 events trip circuit supervision
• User activity logging for 2048 entries • Connector types: compression type or ring-lug type
• Disturbance report
• Event and trip value recorders
• Event counters
• Supervision of AC input quantities Technical details are available in the RET650 Product
• Insulation gas monitoring function Guide.
• Insulation liquid monitoring function
• Circuit breaker condition monitoring For more information please contact:
• Station battery supervision
ABB AB
• Indication of up to 135 binary signals via 15
Substation Automation Products
three‑color‑state indication LEDs
721 59 Västerås, Sweden
Phone: +46 (0) 21 32 50 00
Measurements
• U, I, P, Q, S, f and cos ϕ www.abb.com/protection-control
• AC input quantities with accuracy better than 0.5%

Metering Note:
• Energy metering function for energy statistics We reserve the right to make technical changes or modify the
• Pulse counting support for energy metering contents of this document without prior notice. ABB AB does
not accept any responsibility whatsoever for potential errors
Communication or possible lack of information in this document.
• IEC 61850-8-1 including GOOSE messaging We reserve all rights in this document and in the subject
• DNP 3.0 slave protocol matter and illustrations contained herein. Any reproduction,
• IEC 60870-5-103 serial communication disclosure to third parties or utilization of its contents – in
• Parallel Redundancy Protocol (PRP) according to IEC whole or in part – is forbidden without prior written consent of
62439-3 Ed.2 ABB AB.

Setting, configuration and disturbance handling © Copyright 2013 ABB. All rights reserved.