TECHNICAL DATA
SIZE 50, 80, 100, 150 & 200 NB
DELUGE VALVE Model H3, UL Listed
CHECK VALVE Model-CH
SPRINKLER ALARM UL Listed (Optional)
RELEASE PANEL UL Listed (Optional)
WATER FLOW UL Listed
SWITCH
SOLENOID VALVE 24V DC, UL Listed
AUTOMATIC AIR Oil-less Risermount
SUPERVISOR Compressor (Optional)
AIR PRESSURE PMD-1 (Optional)
MAINTENANCE
DEVICE
MANUAL SYSTEM UL Listed, Butterfly Valve -
SHUTOFF VALVE Standard supply.
(Gate Valve - Optional)
MAXIMUM WORKING 17.5 Kg./sq.cm. (250 PSI)
PRESSURE The Releasing Panel is operated by either a fire detec-
SYSTEM END Grooved (Standard supply) tion device or manual electric pull station. In order for
CONNECTION Flanged (Optional supply) the Double Interlock Pre-action System to automat-
ically actuate, two independent events must occur.
APPROVAL UL Listed Zone 1 of the Releasing Panel must operate upon
automatic operation of the electric fire detection
DESCRIPTION initiating circuit or operation of the electric-manu-
al pull initiating circuit, and Zone 2 of the Releasing
The Double Interlock Preaction System with Electric/ Panel must operate via the Low Air Pressure Alarm
Electric Release is generally used to protect water Switch upon loss of air pressure from the sprinkler
sensitive areas such as computer rooms, storage system piping, due to operation of one or more sprin-
areas, refrigerated areas etc., to avoid water damage klers. The Double Interlock Preaction System will au-
due to inadvertent flooding of the sprinkler system tomatically actuate only when both Zone 1 and Zone
piping. 2 of the Releasing Panel have operated, energizing the
Solenoid Valve.
In normal condition, preaction system does not contain
water in the sprinkler piping. The sprinkler piping Deluge Valve H3 is diaphragm valve as described in
contains air pressure for the purpose of supervising Technical Data Sheet HD 235.
its leak tightness.
This system utilizes a Deluge Valve H3 and Riser INSTALLATION & COMMISSIONING
Check Valve model CH. The Riser Check Valve isolates The preaction system valves, panel, indicators
the Deluge Valve from the system air pressure. Riser must be installed in a readily visible and accessible
Check Valve provides an air check so that the system location. The system valves and accessory shall not be
can be automatically pressurized with a supervisory installed in an area having temperature less than
air or nitrogen pressure of 18 PSI (1.26 Bar). A su- 4oC (40oF). Heat tracing to system valve and
pervisory low pressure alarm switch can be set at accessory is not permissible. The system must be
6 PSI (0.42 Bar), on decreasing pressure, to indicate installed and operated carefully by a trained person,
whether there are any abnormal leaks in the sprinkler having good knowledge of equipment. All system piping
system piping. Loss of air pressure from the system must be flushed thoroughly before commissioning.
due to accidental leakage will not cause Deluge Valve
to open. After initial successful tests, an authorized person
must be trained to perform inspection, testing and
The releasing trim for Deluge Valve utilizes a Solenoid maintenance of the system.
Valve that is energized with cross-zone releasing cir-
cuit of release panel.
CAUTION
The steps b & c must be performed very quickly to
prevent water flow to riser.
NOTE: For abnormal condition of deluge valve refer
the data sheet No. HD235.
12
10
17
9
16
4 7 14
10 13
15
11
12 3
2 6
18
5
1
FRONT VIEW
10
8 17
16
4
12
7 15
11
15
18
14
REAR VIEW
* OPTIONAL SUPPLLY
** NOT SUPPLLIED BY HD FIRE
NOTES:
DELUGE VALVE END CONNECTION (OPTIONAL - G X G/ F X F) F = FLANGE END
CHECK VALVE END CONNECTION (OPTIONAL - G X G/ F X G / F X F) G = GROOVE END
BUTTERFLY VALVE END CONNECTION (OPTIONAL - G X G/ WAFER TYPE / LUG TYPE)
PRESSURE GAUGE (OPTIONAL - HDP-1 / HDP-2)
OPTIONAL TRIM SUPPLY - LOOSE / SEMI ASSEMBLED)
SHAPE OF FITTINGS / VALVES MAY CHANGE.
SYSTEM PIPING, SPRINKLER, DETECTOR NOT SUPPLIED BY HD FIRE
PRIMING LINE BY OTHERS
ORDERING INFORMATION
X XX X X X X
LIMITED WARRANTY
HD FIRE PROTECT PVT. LTD. hereby referred to as HD FIRE warrants to the original purchaser of the fire protection products manufactured by HD FIRE and to any other person
to whom such equipment is transferred, that such products will be free from defect in material and workmanship under normal use and care, for two (2) years from the date of
shipment by HD FIRE. Products or Components supplied or used by HD FIRE, but manufactured by others, are warranted only to the extent of the manufacturer’s warranty.
No warranty is given for product or components which have been subject to misuse, improper installation, corrosion, unauthorized repair, alteration or un-maintained.
HD FIRE shall not be responsible for system design errors or improper installation or inaccurate or incomplete information supplied by buyer or buyer’s representatives.
HD FIRE will repair or replace defective material free of charge, which is returned to our factory, transportation charge prepaid, provided after our inspection the material is
found to have been defective at the time of initial shipment from our works. HD FIRE shall not be liable for any incidental or consequential loss, damage or expense arising directly
or indirectly from the use of the product including damages for injury to person, damages to property and penalties resulting from any products and components manufactured
by HD FIRE. HD FIRE shall not be liable for any damages or labour charges or expense in making repair or adjustment to the product. HD FIRE shall not be liable for any
damages or charges sustained in the adaptation or use of its engineering data & services. In no event shall HD Fire’s product liability exceed an amount equal to the sale price.
The foregoing warranty is exclusive and in lieu of all other warranties and representation whether expressed, implied, oral or written, including but not limited
to, any implied warranties or merchantability or fitness for a particular purpose. All such other warranties and representations are hereby cancelled.
NOTICE :
The equipment presented in this bulletin is to be installed in accordance with the latest publication standards of NFPA or other similar organisations and also with the
provision of government codes or ordinances wherever applicable.
The information provided by us is to the best of our knowledge and belief, and consist of general guidelines only. Site handling and installation control is not in our scope.
Hence we give no guarantee for result and take no liability for damages, loss or penalties whatsoever, resulting from our suggestion, information, recommendation or
damages due to our product.
Product development is a continuous programme of HD FIRE PROTECT PVT. LTD. and hence the right to modify any specification without prior notice is reserved with
the company.