Current Release Notes
Current Release Notes
8 Release Notes
Page 1 of 98
Table of Contents
Table of Contents ............................................................................................................ 2 1. Overview ..................................................................................................................... 5 1.1. Single Bug Fix in 10.3.0.8..................................................................................... 5 1.2. New Features added and a Single Bug Fix in 10.3.0.7......................................... 5 1.3. New Features added and Bug Fixes in 10.3.0.5 ................................................... 5 1.4. Bug Fix only in 10.2.0.19 ...................................................................................... 6 1.5. New Features added in 10.2.0.18......................................................................... 6 1.6. New Features added in 10.2................................................................................. 6 1.7. New Features added in 10.1................................................................................. 6 1.8. New Features added in 10.0................................................................................. 6 1.9. New Features added in 9.0................................................................................... 6 1.10. Incorrect SS1 Firmware in VIA!Tools 9.0.2.7 ...................................................... 7 1.11. Bug Fixes............................................................................................................ 7 1.12. The new Vico Program ....................................................................................... 7 1.13. Importing Projects from VIA! Tools 8 and earlier ................................................ 7 1.14. New S86 Firmware Download Procedure........................................................... 8 2. Component Versions................................................................................................... 8 3. Note on Installation...................................................................................................... 9 4. Previous Firmware updates......................................................................................... 9 5. Installation Changes.................................................................................................... 9 5.1. Install Directory ..................................................................................................... 9 5.2. Customer Files.................................................................................................... 10 5.3. Custom Files....................................................................................................... 10 5.4. Manually Uninstall Previous VIA!Tools Installs ................................................... 10 6. Prompt for Home Logic Dealer during Installation ..................................................... 10 7. Multiple System SS-1s and the new SC1.................................................................. 11 7.1. Multiple System SS-1s........................................................................................ 11 7.1.1. Connecting Multiple System SS-1s .............................................................. 11 7.1.2. Programming Multiple SS-1s........................................................................ 13 7.2. SC1..................................................................................................................... 13 7.2.1. Connecting SC1s ......................................................................................... 13 7.2.2. Powering SC1s ............................................................................................ 13 7.2.3. Programming SC1s ...................................................................................... 14 8. New Firmware for SS1 and 2-way Drivers ................................................................ 14 9. Advanced Lighting..................................................................................................... 14 10. Support for Jandy AquaLink RS Control Systems ................................................... 15 11. Support for Sunfire TGM-100 Digital Media Server ................................................. 15 12. VIA1 Panel Screen Calibration ................................................................................ 15 13. New S86 Firmware.................................................................................................. 16 Page 2 of 98
VIA!Tools 10.3.0.8 Release Notes 14. New S86 Firmware Download Procedure ............................................................... 16 15. Firmware Download to D12, D16, and C2............................................................... 19 16. ELAN DT22 Dual AM/FM Tuner .............................................................................. 20 16.1. Adding a DT22 to a VIA! Tools Project ............................................................. 21 16.2. Connecting a DT22 to the VIAnet bus ............................................................. 25 17. Gamma Correction for OLE XL ............................................................................... 26 18. Customer reported defects that were fixed:............................................................. 27 18.1. Problem after adding 128 TV Icons in Hobbs Editor ......................................... 27 18.2. Serial drivers not available for programming on Overlay pages........................ 28 18.3. Pressing Channel UP on OLE goes up 2 or 3 Channels .................................. 28 18.4. VIA1 Off Page had Long Timeout ..................................................................... 28 18.5. Ademco Lockout ............................................................................................... 28 18.6. Home Logic Passthru broken if not using Vico ................................................. 28 18.7. Projects built in beta versions of VIA Tools (such as VIA Tools 9.0.0.9) incompatible with official releases.............................................................................. 29 18.8. Incorrect SS1 Firmware in VIA!Tools 9.0.2.7 .................................................... 29 18.9. Cannot add Zone SS1 serial commands to source button................................ 29 18.10. Z880 Serial commands not sent out SS1 Elan System Port........................... 30 18.11. VIA!migo not working on Wireless Panels ...................................................... 30 18.12. S86 serial port sleeps 1 minute when Home Logic ramps volume.................. 30 18.13. S86 confused by non-S86 serial commands................................................... 30 18.14. No button feedback on Lite Touch Lights Page .............................................. 30 18.15. TGM-100 cannot be controlled by IR on VIA1 Panels .................................... 30 18.16. Autobuild Commands on OLE Templates....................................................... 30 18.17. Two-way Feedback on VIA1 broken in 10.1.0.5 ............................................. 31 18.18. ZNET Bridge on SC1 blocks user from adding Driver..................................... 31 18.19. Jandy Driver not supporting Optional Equipment............................................ 31 18.20. Southwest Motif on VIA 7 and 10 missing Volume Bar ................................ 31 18.21. OLE XL TV Icons problems on Traditional Neutral ......................................... 31 18.22. DT22 Commands Correct but display wrong text ........................................... 31 18.23. VIA!Tools changes Z880 to V8 on initial loading............................................. 31 18.24. OLE XL IR sensor disabled............................................................................. 32 18.25. S86 Query Responses Lag After Invalid Serial Commands ........................... 32 18.26. S86 and OLE download problems on Vista and Windows 7 ........................... 32 18.27. OLE IR Sensor and Speaker re-enabled before Download ............................ 32 18.28. Use of Unsupported OLE XL Motifs Causes Problems................................... 32 19. Known Issues with VIA!Tools 10.3.0.8 .................................................................... 33 19.1. Convert to Vico issues.................................................................................... 33 19.1.1. Two-way Drivers Initialized to Default Values ............................................ 33 19.1.2. DJ and DVDj on System Ports not auto selected on Vico Conversion ....... 33 19.1.3. Drivers programmed for Ethernet reset to RS-232..................................... 33 Page 3 of 98
VIA!Tools 10.3.0.8 Release Notes 19.2. VIA2 does not handle 2-way feedback for Drivers with Tag ID > 7................... 34 Appendix A............................................................................................. 35 Vico Tutorial............................................................................................. 35 1. Starting a New Project............................................................................................... 35 2. Importing a Project from VIA Tools 8 (or earlier) ....................................................... 49 3. Convert to Vico process.......................................................................................... 51 4. Loading a Panel Template from VIA Tools 8 (or earlier) ........................................... 58 5. Loading a Source Template from VIA Tools 8 (or earlier) ......................................... 60 6. Loading a Function Page from VIA Tools 8 (or earlier) ............................................. 61 7. Loading an OLE Template from VIA Tools 8 (or earlier) ........................................... 62 8. Adding 2-way components to VIA! Panels ................................................................ 63 9. Adding 2-way components to OLE touchpads .......................................................... 66 Appendix B............................................................................................. 68 Lights Page Programming Tutorial ...................................................... 68 Appendix C............................................................................................. 78 Forcing a Firmware Update for the SS1............................................... 78 Appendix D............................................................................................. 80 VIA!Tools Programming for the Sunfire TGM-100 .............................. 80
Page 4 of 98
1. Overview
1.1. Single Bug Fix in 10.3.0.8
With the introduction of the High Resolution OLE XL panel in the Spring of 2010, only six of the original 36 OLE XL Motifs are being supported. A bug in the Installation Package allowed the 30 unsupported Motifs to remain in the Motifs directory. Attempting to use these unsupported Motifs caused problems. This new Installation Package will delete the Motifs directory before installing the six supported Motifs.
Page 5 of 98
NOTE: The DT22 is NOT supported on non-EM VIA1 panels, ie, the VIA64 and the non-EM VIA40. It is supported on the VIA1 EM panels (VIA 4.0EM, VIA 7.0EM, and VIA 10.0EM), as well as the wireless panels XP84 and N800, and the OLE 2 and OLE XL.
VIA!Tools 10.3.0.8 Release Notes LiteTouch 5000 Jandy AquaLink RS Control Systems Multiple System SS-1s SC1
These features will be described later in the Release Notes. If you are not using any of the above, there is no substantial benefit to upgrade and we recommend you continue to use VIA! Tools 8.2.4.1. IT IS HIGHLY RECOMMENDED THAT NEW DEALERS USE THE LATEST VERSION VIA! TOOLS 8!
Page 7 of 98
VIA!Tools 10.3.0.8 Release Notes However, in order to use any of the new 9.0 and 10.0 features listed above, the project must be converted to the new Vico format for System SS-1 and SC1 programming. This is accomplished by pressing the Convert to Vico button on the System Tab, in the System Components box, under the SS-1 checkbox. (If the imported project uses an SC-4, it must be changed to an SS-1 (by checking the SS1 checkbox) before the Convert to Vico button will appear.) After running the Convert to Vico conversion process, the following steps need to be performed: 1. download to the System SS-1 2. for every UI in the project: a. select the UI b. assign old style drivers to the new Vico style drivers c. download to the UI For more information on this procedure, see the Vico tutorial in the Appendix A.
2. Component Versions
This package of VIA!Tools contains the following versions of the various components: VIA!Tools Package VIA!Tools VIANet Transfer Hobbs (OLE XL Function Page Layout Editor) Nietzsche (Advance Light Button Layout Editor) Spinoza (System SS Editor pre-Vico) Vico (System Controller Editor) 10.3.0.8 10.3.1.10 5.15.1.1 8.2.1.302 10.1.0.230 0.0.0.11 10.2.0.900
Page 8 of 98
VIA!Tools 10.3.0.8 Release Notes VIA1 Panel OLE 2 OLE XL SS1 S86 S12 98 1.3.1.1 1.3.2.2 1.4.1.1 2.0.1.3 2.2.4
3. Note on Installation
In this and subsequent versions of VIA!Tools an automatic check is performed to verify Microsoft .NET 1.1 and Microsoft .NET 2.0 are installed. If these files are not already installed, the VIA!Tools Installer will download and install them automatically from the Internet. In this case a connection to the Internet must be present to complete the installation process. The VIA!Tools installation will not work unless the current Microsoft .NET files are installed. If they are already installed then no Internet connection is required. An Internet connection is also required if you elect to download the International Icons. Note: A Special (much larger) version of the installation package is available through Customer Support that will install from a USB drive or CD and does not require the Internet connection.
5. Installation Changes
5.1. Install Directory
VIA!Tools 10.3.0.8 will install in a different directory than previous VIA!Tools versions. For non Vista machines, the default install directory for VIA!Tools 10.3.0.8 is C:\Program Files\ELAN Home Systems\VIA Tools 10. For Vista machines, the
Page 9 of 98
VIA!Tools 10.3.0.8 Release Notes default install directory for VIA!Tools 10.3.0.8 is C:\ELAN Home Systems\VIA Tools 10. VIA!Tools 10.3.0.8 will not overwrite the VIA!Tools installed in the VIA Tools 7.0, VIA Tools 8.0, and VIA Tools 9.0 directories.
Click on OK. 3. To disable the Home Logic Configuration options (Ethernet on SS1), follow the above procedures, but start out by double clicking on EthernetSetup_Disable.reg and clicking on Yes and OK.
VIA!Tools 10.3.0.8 Release Notes To use Multiple System SS-1s, each one must be connected to the VIAnet bus. This can be done in many ways, but here are the two recommended options. For systems with only one system chassis (S12, S8.6, or S6) with one precision panel, connect the precision panel to the multiple SS-1s using a RJ45 splitter. See Diagram 1 Connecting multiple SS1s to a Single Chassis System. For systems with multiple chassiss, connect one SS-1 to each precision panel. If there are more SS-1s than precision panels, use RJ45 splitter(s) to accommodate the remaining SS-1s. See Diagram 2 Connecting multiple SS1s to a Multi-Chassis System.
Page 12 of 98
7.2. SC1
7.2.1. Connecting SC1s
VIA! Tools 9.0,10.0, and 10.1 also support the new Serial Controller SC1. The SC1 accepts a 1-way or 2-way driver and provides serial control of a single device. There can be up to 32 SC1s in a system, but only 13 of them can have a 2-way driver loaded. The SC1 must be connected to the VIAnet bus. This can be done in many ways. It can be done in a similar manner as multiple SS-1s are connected (see Diagram number 1 and Diagram number 2). The SC1s can also be daisy chained together between the precision panel and the System SS-1. Connect the precision panel to the VIAnet IN jack on the first SC1; connect the VIAnet OUT jack on the first SC1 to the VIAnet IN jack on the second SC1. Repeat this daisy chaining until the last SC1 is connected from its OUT jack to the VIAnet jack on the System SS-1.
VIA!Tools 10.3.0.8 Release Notes or if connected to the Zone connection on a precision panel. If the 12v is absent, then the SC1 needs to be externally powered by a PWR3 12VDC power supply. For more information on the SC1, refer to the Installation Manual for the SC1 Serial Controller.
9. Advanced Lighting
VIA! Tools 9.0 and 10.0 support advanced programming for Lutron Radio RA, Lutron HomeWorks, and LiteTouch 5000. In addition to being able to build function pages for
Page 14 of 98
VIA!Tools 10.3.0.8 Release Notes control of these lighting systems, special function pages can be built on the Lights Page providing control and button feedback (button will display in one of two colors, one for on, the other for off). The button feedback feature for Lutron HomeWorks and LiteTouch 5000 is supported only on VIA1 Panels with Enhanced Memory (VIA! 4.0-EM, VIA! 7.0-EM, VIA! 10.0-EM, VIA!Valet 10.0-EM) and on the VIA2 Wireless Panels (VIA2, N800, and XP-8.4). If the button feedback feature is programmed on any other type VIA! Panel (VIA! 4.0, VIA! 6.4, and VIA!Valet 6.4), the panel will control the device, but the buttons will not show feedback. The button feedback feature for Lutron Radio RA is supported on all types of VIA panels. For info on how to program the Lights Page, see Appendix B.
Page 15 of 98
VIA!Tools 10.3.0.8 Release Notes 1. The VIA1 Panel must have been previously programmed; if not programmed, download any programming to it 2. Press and Hold the System Status Bar for 10 seconds after 10 seconds, the calibration screen will appear 3. Touch the cross-hairs in the upper left corner, then touch the cross-hairs in the lower right corner; or touch in the center of the screen to use the default settings (These directions are displayed on the screen itself) 4. The screen is now calibrated
Page 16 of 98
When this screen appears, press the Force Update button. This will open the following window where the user needs to select which Comm Port the S-86 is connected to.
Select the correct Comm Port and press Select. This will transfer the S-86 firmware (this includes Elans S86 boot-loader). When finished transferring, the screen will look something like this:
Page 17 of 98
At this point, the user should hit exit to leave the program. By default, the FailSafe Downloader will download the latest firmware versions available. If the user wants to download to an earlier version, then the user should click on the File Selection menu item and choose which version is desired:
Page 18 of 98
This screen shot shows four available S86 firmware versions. This and future releases of VIA!Tools will have different versions of the S86 firmware.
Page 19 of 98
Page 20 of 98
2. Select the DT22 being added (up to two chassis are supported per system) and click Add
Page 21 of 98
3. The DT22 Chassis is added; there are no settings to set, and no downloads to perform; just click Return to VIA Tools
4. To add a DT22 Tuner to a VIA panel, go to the Layout tab, select Add/Remove/Save source buttons, then select Serial two-way (w/ feedback)
Page 22 of 98
6. There are two AM/FM tuners and two Sirius Tuners on each DT22 (US version) chassis (The DT22-240 has only the two AM/FM tuners); select the desired one
Page 23 of 98
7. The default name for the tuner will appear; either accept the default or enter a new name, and then click OK
8. The tuner is now added. Continue with normal programming (ie, select audio source for this device, etc).
Page 24 of 98
EXAMPLE 2: When connecting the DT22 to any ELAN System with a precision panel, simply connect the DT22 to the VIANet port. If the system has a System SS1 or SC1, it can be connected at the end of the VIANet daisy chain as shown below:
Page 25 of 98
ENTER
Press the UP or DOWN button to move the highlight to OLED info, press ENTER and this Menu will appear:
Page 26 of 98
UP DOWN
Select Gamma and press ENTER. The following Menu will appear:
UP
. DOWN
Now press UP and / or DOWN till the two boxes look correct, where correct is defined as the upper box is pure white and the bottom box is a gradient from black to white. Changing the Gamma value from 1 to 6 will change the amount of red, green, and blue tint in the boxes. Look for the Gamma value with the least amount of tint. Once this is found, select Save & Exit and press ENTER.
Page 27 of 98
Page 28 of 98
VIA!Tools 10.3.0.8 Release Notes The user is allowed to select Ethernet configuration for the SS1 System Port in VIA Tools, but it is not sent correctly to the SS1. This has been fixed in this release.
18.7. Projects built in beta versions of VIA Tools (such as VIA Tools 9.0.0.9) incompatible with official releases
Some dealers were sent beta version of VIA Tools 9 to support the sale of multiple SS1s. The Vico format used in these early beta versions was changed in later versions. The two formats are incompatible with each other. So if a project was built in an early beta version, and then opened in an official version (VIA Tools 9.0.0.34 is the first official release), the serial commands in the SS1 may not work. This new release of VIA Tools will check the event log to check if the Project was ever modified using a beta version of VIA Tools. If this is found to be true, the following warning message will be displayed:
Elan Tech Support will walk the user thru the process needed to correct this issue.
Page 29 of 98
18.10. Z880 Serial commands not sent out SS1 Elan System Port
When the Z880 is configured in Vico to use the System Port, the serial commands are not sent out the System Port. This problem has been corrected.
18.12. S86 serial port sleeps 1 minute when Home Logic ramps volume
When the user ramps the Volume Up or Down on a Home Logic panel, the serial port on the S86 appeared to sleep for about 40-60 seconds. This bug has been fixed in the S86 so that the S86 serial port remains active.
Page 30 of 98
VIA!Tools 10.3.0.8 Release Notes system) so the user will not be prompted to assign a serial driver for a device that does not exist.
VIA!Tools 10.3.0.8 Release Notes is defaulted to checked. If the first Project opened has a Z880 in it, the V8 checkbox remained checked indicating the Project has a V8 in it. All the existing Z880 commands are now bogus. This only happens with the first Project loaded into VIA!Tools after it is launched and only if the Project has a Z880; otherwise, the problem does not occur. The software has been fixed so that the Composite Video switcher of the newly loaded Project is properly noted.
Page 32 of 98
19.1.2. DJ and DVDj on System Ports not auto selected on Vico Conversion
If a Project in VIA Tools 8.0 had an S86, V883, VIA!DVDJ and VIA!dj on the SS1s system port, after running the Vico conversion, the S86 and V883 would be assigned to the SS-1s system port. The can be seen in Vicos Elan Devices tab. However, the VIA!DVDJ and the VIA!dj would NOT be automatically assigned. This needs to be done manually.
Page 33 of 98
19.2. VIA2 does not handle 2-way feedback for Drivers with Tag ID >7
When using multiple SS-1s with 7 or more 2-way drivers, the VIA2 wireless panel will not display feedback from the 2-way drivers with a Tag ID greater than 7. The VIA1 panels and the N800 and XP-8.4 panels will work.
Page 34 of 98
Appendix A
Vico Tutorial
Page 35 of 98
VIA!Tools 10.3.0.8 Release Notes b. While the Vico task is launching, the following splash screen will display:
Page 36 of 98
d. The Add System Device window appears. Select Type SS1. Use the default name System SS-1 or enter your own. Click on Add.
Page 37 of 98
VIA!Tools 10.3.0.8 Release Notes f. To add an SC1, click on Add New System Device, and then select Type SC1. Use the default name, or change it to a more meaningful name. Click Add.
g. Add additional SC1s as needed. The SS-1s and SC1s can be added in any order.
Page 38 of 98
VIA!Tools 10.3.0.8 Release Notes h. With multiple SS1s come multiple System Ports (one System Port per SS1). The ELAN devices (such as S12, S86, VIA!dj, V883, etc) which previously were daisychained off the System Port of the one and only System SS1, can now be hung off the System Ports on different System SS1s. The user selects the Elan Devices tab, and then selects which System SS1 the various ELAN devices will be attached to its System Port.
i. Adding Drivers to the System SS1s There are five types of drivers for the System SS1. The first four currently exist in VIA Tools 8. The fifth type is an advanced two-way driver providing on/off feedback on the button. First, select a System Device from the Project Setup display. This will bring up the following display which shows 4 drivers, one for each comm. port on the SS1. Click on one of the Add Driver buttons.
Page 39 of 98
Clicking on the first Add Driver button will bring up the Select Driver Type window with a default Driver Name of Driver 1. It also defaults to the One Way Driver type.
Page 40 of 98
VIA!Tools 10.3.0.8 Release Notes i. One Way Driver The first driver type is the One Way Driver. This is the same option as the Load driver from a file when programming a System SS1 in VIA Tools 8. The user chooses a driver from a list of existing one way driver files. In the screen shot below, the default Driver Name was changed to Denon AVR, the Denon folder was selected in the left window pane causing the Denon driver/files to be displayed in the right window pane, and the driver for the Denon AVR was selected. Pressing OK will add this driver.
ii. One Way Driver from Wizard The second driver type is the One Way Driver from Wizard. This is the same option as the Use wizard to create a driver when programming a System SS1 in VIA Tools 8. The user chooses a wizard from a list of wizards. In the screen shot below, the default Driver Name was changed to Krystal, and the Krystal wizard was selected.
Page 41 of 98
a. Pressing OK will open the Krystal wizard, which is the same wizard application in VIA Tools 8.
Page 42 of 98
VIA!Tools 10.3.0.8 Release Notes iii. One Way Blank Driver The third driver type is the One Way Blank Driver. This is the same option as the Create a new driver when programming a System SS1 in VIA Tools 8. The user chooses a wizard from a list of wizards. In the screen shot below, the default Driver Name was changed to Custom.
Pressing OK will bring up the following screen where the user can add commands to build a new driver.
Page 43 of 98
iv. Two-way Driver Windowed The fourth driver type is the Two-way Driver - Windowed. This is the same option as the Add a TWO-way driver when programming a System SS1 in VIA Tools 8. The user chooses a driver from a list of existing two-way drives. In the screen shot below, the default Driver Name was changed to april, and the driver for Aprilaire was selected.
Page 44 of 98
Pressing OK will add this driver and take the user to the Options page (if any) for the selected driver. The Aprilaire two-way driver has the following options:
Page 45 of 98
v. Two-way Driver Advanced The fifth and final driver type is the Two-way Driver - Advanced. This is a new driver type that provides feedback on the buttons instead of in the traditional two-way feedback window. The user chooses a driver from a list of existing two-way advanced drives. In the screen shot below, the default Driver Name was changed to LutronHW, and the driver for Lutron Homeworks was selected.
Pressing OK will add this driver and take the user to the Options page (if any) for the selected driver. The Lutron Homeworks two-way driver has the following options, where the user can add keypads and name buttons:
Page 46 of 98
j. System SS1 Ethernet Port Settings The System SS1 Ethernet Port Settings are displayed and programmable on the Device Setup tab. The programming options are the same as those in VIA Tools 8 on the Sys SS tab via the RS-232/Ethernet Setup button. In the following screen shot, this System SS1 has been programmed to use a static IP address and the commands directed toward the System SS1s System Port will be forwarded to the designated IP address. Also, the serial commands for the first two drivers have also been routed to an IP address.
Page 47 of 98
The Ethernet settings for the first two drivers were changed by pressing the Edit button to the right of each driver. That brings up the following screen where the user enters the IP address and IP Port address of the target device (in most cases, this will be the Home Logic brick).
Page 48 of 98
k. Adding a driver to the SC1 is the same as adding a driver to an SS1 with two differences only one driver can be added to the SC1 instead of the four drivers that can be added to the SS1; and there are no Ethernet settings available on the SC1. The following screen shot shows this.
Click on Add Driver and add a driver in the same manner as when adding one to an SS1.
VIA!Tools 10.3.0.8 Release Notes 3. download as appropriate to Panels, OLE, SC4, etc 4. youre done b. Project has SC4 and you want to use a single SS1 in project 1. On System Tab, select SS1 Convert to Vico button shows up 2. It is not necessary to Convert to Vico but if you do, you will get the new 2-way drivers: Jandy, advanced Lutron HomeWorks, and advanced LiteTouch 3. If you want to Convert to Vico: a. press Convert to Vico b. follow the Convert to Vico process (See Item 3 below) c. Project has SC4 and you want Multiple SS1s and/or SC1s in project 1. On System Tab, select SS1 Convert to Vico button shows up 2. Press Convert to Vico 3. Follow the Convert to Vico process (See Item 3 below) 4. The existing SC4 drivers are now on the first SS1 named System SS 5. Add additional System SS1s , SC1s, and drivers as needed d. Project has single SS1 and you are keeping the single SS1 1. It is not necessary to Convert to Vico but if you do, you will get the new 2-way drivers: Jandy, advanced Lutron HomeWorks, and advanced LiteTouch 2. If you want to Convert to Vico: a. press Convert to Vico b. follow the Convert to Vico process (See Item 3 below) e. Project has single SS1 and you want multiple SS1s and/or SC1s in Project 1. On System Tab, press Convert to Vico 2. Follow the Convert to Vico process (See Item 3 below) 3. The existing SS1 drivers are now on the first SS1 named System SS 4. Add additional System SS1s and drivers as needed
Page 50 of 98
b. The following window will appear, asking for confirmation of Converting to Vico. Press Convert this will convert the SS-1 configuration and launch the Vico Application.
Page 51 of 98
VIA!Tools 10.3.0.8 Release Notes c. Click on the System SS in the center window.
d. In the Vico Conversion process, the two-way drivers are imported with the default settings. At this point, we need to manually change the settings back to the correct settings for this Project. For example, lets look at the Aprilaire two-way driver. Click on the Aprilaire.
Page 52 of 98
VIA!Tools 10.3.0.8 Release Notes e. This shows the default options for the Aprilaire driver. System type is H/C (normal); Number of Zones is 1; No Remote Sensor.
f. Set the options to the appropriate values for this Project (say, 5 Zones, with a Remote Sensor in Zone 1). Then select Project Setup so you can download to the System SS1.
Page 53 of 98
VIA!Tools 10.3.0.8 Release Notes g. On the Project Setup page, press Transfer Selected Configuration to Device.
h. The VIANet Transfer task transfers the configuration to the System SS1.
Page 54 of 98
i. When it finishes, click on Done. This will bring back the Vico screen. Select Return to VIA Tools to return back to VIA Tools.
j. Pressing Return to VIA Tools basically just exits Vico. If, between the time you launched Vico and the time you pressed Return to VIA Tools, you did not access any other programs, you will be back in VIA Tools. If you did access other programs, you will need to manually select the VIA Tools program. k. Each UI Panel must be individually converted to Vico and downloaded to. As each Panel is selected, a check is made to see if all serial commands have been converted to Vico serial commands. If not, the following window will pop up:
Page 55 of 98
l. The above snapshot shows four drivers found on the panel that are not in Vico mode and need to be assigned to a driver on the System SS1 that is in Vico mode. To do this, select the drivers one at a time and assign them to the appropriate driver on the System SS1 that is in Vico mode. Start with the Advent select Advent under the Drivers found on panel on the left side of the display. This will populate the Drivers found on system SS-1 (Vico mode) on the right side of the display. Now select the corresponding Advent driver on the right hand side of the display, and click on Assign.
Page 56 of 98
VIA!Tools 10.3.0.8 Release Notes m. Repeat for the remaining drivers. n. If a Serial Command in the panel is not found in the selected Driver, then the Conversion Error pop-up window is displayed showing which commands were not found. This should only occur when there were Conversion Errors in the original 8.0 Project that was imported. The following screen shot shows the Conversion Errors. In order to get these errors, in the VIA Tools 8 Project there were originally two Aprilaire Zones; but then Zone 2 was removed from the Aprilaire driver causing the VIA Tools 8 Project to have Conversion Errors. The Project was exported and then imported into VIA Tools 9 and converted to Vico.
Click OK. o. There are two ways to clean up the Conversion Errors. One is to add the missing Serial commands to the driver (this can be done in Vico). The other is to disable the missing commands (they will be removed from the panel later, on download to the panel). To disable / remove the commands from the panel that were not found in any existing driver in the system, press the Disable Old Style Commands button:
Page 57 of 98
Page 58 of 98
b. You will get the message (if you have serial commands on Panel Template):
Page 59 of 98
VIA!Tools 10.3.0.8 Release Notes e. Click No (unless if you want to look it is not necessary as these entries will be evident later) f. The following screen will appear showing which drivers on the panel were not found in the Project. You will now have the opportunity to assign the old driver names to the new driver names. The following screen shows Driver april selected, and its possible Drivers on the System SS-1:
g. Make the assignments in the same way as described in the Convert to Vico process.
Page 60 of 98
c. Make the assignments in the same way as described in the Convert to Vico process.
Page 61 of 98
e. Click No (unless if you want to look it is not necessary as these entries will be evident later) f. Click Done on the Add/Remove/Save Function Page dialog box. g. The following screen will appear showing which drivers on the panel were not found in the Project. You will now have the opportunity to assign the old driver names to the new driver names:
h. Make the assignments in the same way as described in the Convert to Vico process.
Page 62 of 98
VIA!Tools 10.3.0.8 Release Notes b. The following screen will appear showing which drivers on the panel were not found in the Project. You will now have the opportunity to assign the old driver names to the new driver names:
c. Make the assignments in the same way as described in the Convert to Vico process.
Page 63 of 98
This screen shows only the two-way drivers on each of the System SS-1s and SC-1s. If there are no two-way drivers on a serial controller, then only the serial controller name will be shown (as is the case for the SC1 Direct TV controller; it has the one-way driver for Direct TV). b. To select a driver, click on the driver name, and then click on OK. Or one can doubleclick on the driver name. c. As before (in VIA Tools 8), additional screens will pop up prompting for more information, such as Source Name, DTNR or XMR Tuner, Aprilaire Zone, etc. In most cases, the additional screens are the same. A few are different, such as the DTNR, which is shown below:
Page 64 of 98
Select Tuner 1 or Tuner 2 (you cannot select both, as this is adding only one Source Button) and click OK, or double-click on Tuner 1 or Tuner 2.
Page 65 of 98
b. For this example, select the DTNR1 XL.OLE_Templates2 file for OLE serial control of DTNR 1. c. The user must now associated the driver name in the template with one of the drivers actually in the project. Click on the old style driver name on the left side of the window, then click on the appropriate new style driver name on the right side, and then press Assign.
Page 66 of 98
d. Click Done.
Page 67 of 98
Page 68 of 98
3. The Light Button Parameters Setting window pops up. Select the Enabled Advance Lighting option. Click OK.
Page 69 of 98
VIA! Tools 10.3.0.8 Release Notes 4. Double-click on the Lights Icon to bring up the Advance Lighting programming function.
5. Select Add in the Active Keypads On This Panel box. This will add keypads to the Lights Function Page. Each keypad added will have its own Function Page, with the main Function Page containing a jump button for each keypad.
Page 70 of 98
6. Select one of the Advance Lights driver on the left side, and then select one of its Keypads which are listed on the right side. Then click on Add to add the Keypad.
Page 71 of 98
VIA! Tools 10.3.0.8 Release Notes 7. Build the Lights Function Page layout for each Keypad. a. Select a Keypad when a Keypad is selected, its available buttons appear in the Buttons on selected keypad box b. Select the Buttons check each checkbox of the buttons desired; as the buttons are checked, they are added to the center of the panel display. c. Click on the Align Buttons button this will align the buttons to the grid being displayed on the panel display The screen shot below shows the screen before clicking on Align Buttons.
8. Now press the Align Buttons button to snap the buttons to the grid.
Page 72 of 98
9. The button layout can be changed in a number of ways. a. Change the grid layout and click on Align Buttons again i. The top left corner of the grid can be changed by changing the Left and Top values using the decrement and increment arrows ii. The width and height of each grid element can be changed by adjusting the Width and Height values using the decrement and increment arrows iii. The number of columns can be changed to 3 or 4 iv. The grid layout can be saved and restored using the Save and Read buttons v. The defaults for the grid layout can be restored by using the Defaults button b. Use the cursor to select a button and then use the mouse to click & drag the button to its desired location c. Use the four arrow keys to move the selected button in one of the four directions (up, own, left, right)
Page 73 of 98
10. The button can be changed to one of eight shapes and sizes, depending on the Motif. To change the button, select it first, and then click on the Change Button button which is in the middle of the four arrow keys. This will bring up the following screen. Click on the button type you want and then click on Select.
Page 74 of 98
11. Repeat the above steps for all Keypads selected for the Lights Page. 12. Set up the Home Page by clicking on the Home Page button. As with the Keypad buttons, the Home Page buttons will initially all be centered in the display.
13. Arrange the Home Page as desired. For example, click on the Align Buttons button to snap the Keypad buttons to the grid. Then using the same techniques described above, change the layout of the Home Page as desired.
Page 75 of 98
14. Save the Lights Page layout as a Template, if desired. Just click on the Template Save As button. This is useful if the homeowner wants the same Lights Page on multiple panels. 15. A Lights Page Template saved previously can be imported to another Panels Light Page in the same project or even a different project. When importing, if the name of the System SS1 or SC1, and the driver name, and the keypad name(s) in the Template all match the names in the current project, then the Template is imported immediately. If any of the names do not match, then the user will be prompted to assign the Keypads used in the Template to the Keypads in the current project. For each Keypad in the Template but not in the current configuration, select a Keypad that is in the current configuration and press Re-Assign. This will assign that Keypad to the one in the current configuration and remove that Keypad from the list of Keypads not found. Repeat for each Keypad. Any Keypad not re-assigned will be removed from the Lights Page.
Page 76 of 98
Page 77 of 98
Page 78 of 98
4) Once again power cycle the SS1 and the new firmware should display.
Page 79 of 98
b. Add an SS1 to the system, if one does not already exist. Then select Device Setup.
Page 80 of 98
c. Select Add Driver to bring up the available drivers on the Add Driver screen, select Two-way Driver Windowed and enter the Driver name TGM Server (or any desired name).
Page 81 of 98
e. Now this brings up the following screen where the TGM-100 configuration data is entered.
f. Three pieces of data need to be entered: i. The IP address of the TGM-100 ii. The fact that this TGM-100 is the Server Page 82 of 98
VIA! Tools 10.3.0.8 Release Notes iii. How many Clients there are in the system In our example, the IP address is 192.168.0.102 and that needs to be entered only if a Wireless XP84 panel is being used. For completeness, it will be entered in. Since this is the Server, the Server Radio Button needs to be checked. And again, in our example, there will be two clients, so the number 2 needs to be selected in the Number of Clients dropdown box.
2. Adding a TGM-100 Client to an SS1 a. Continuing from the above step, press Device Setup so another driver can be added.
Page 83 of 98
b. Click on Add Driver, and select Two-way Driver Windowed, enter a driver name (say, TGM Client1), and select Sunfire TGM100.
Page 84 of 98
c. Click OK, and that will bring up the TGM-100 configuration screen. Enter the address of this TGM-100 (in this example, 192.168.0.103) and select Client 1.
d. In this example, there are two clients, so following steps a, b, and c, Client 2 when added will look like this:
Page 85 of 98
3. Information concerning Servers and Clients When a TGM-100 is configured as a Server, it is given a Unit ID of 1. This can be found in the TGM-100 Classic Admin, under Set Up / Settings / Output Configuration / Output 1.
When a second TGM-100 is configured as a Client, and when that Client is connected to the network and the Server sees him, the Server assigns it the number 2.
Page 86 of 98
The Name field was modified by this user to TGM-100C1 to designate it as Client 1. A more descriptive name such as Family Room could be used as well. When a second Client is configured and connected to the network, the Server will assign it the number 3, and so on for any additional Clients. In VIA!Tools, when the TGM-100 driver is configured for Server, it is expecting the Number field in the TGM-100 to be 1. When a TGM-100 driver is configured for Client 1, it is expecting the Number field to be 2. When a TGM-100 driver is configured for Client 2, it is expecting the Number field to be 3, and so forth for the remainder of the clients. Also, in VIA!Tools, it is assumed that when the Server is configured with one client, it is Client 1. When the Server has two clients, they are Client 1 and Client 2. When the Server has three clients, they are Client 1, Client 2, and Client 3, and so forth. In other words, VIA!Tools will not program the system correctly if the user configures the Server for two clients, and the user assigns drivers for Client 4 and Client 7. 4. VIA1 Panel programming using Serial Controlled TGM-100s The TGM-100 provides a video output for the User Interface, similar to what the VIA!dj and VIA!migo do. When adding a Source Button to a VIA1 panel, the UI video output needs to be associated with the Source. In this example, a S12 is being used as the system controller. Video input 1 is the video UI from the Server; Video input 2 is from Client 1;
Page 87 of 98
VIA! Tools 10.3.0.8 Release Notes and video input 3 is from Client 2. The S12 is also being used to switch the component video from the three TGM-100s. Video inputs 13, 14, and 15 are handling the three component video outputs from the Server. Video inputs 10, 11, and 12 are handling the video outputs from Client 1. Video inputs 7, 8, and 9 are handling the video outputs from Client 2. In this example, Zone 1 and Zone 2 have a TV monitor to receive the component videos. Zone 1 has a VIA1 panel; Zone 2 has a XP84; and Zone 3 has an OLE XL. The S12 Outputs and camera inputs page looks like this:
a. Adding a Source Button for the TGM-100 Server. As when adding any two-way driver Source, go to the Layout tab, select Add/Remove/Save, and select Serial two-way (w/feedback). On the Select TW Driver window, select the TGM Server and click OK. The display will look similar to this:
Page 88 of 98
On the Please, enter name: window, enter a name for the Source. For this example, we will use TGM Svr.
Page 89 of 98
VIA! Tools 10.3.0.8 Release Notes b. Adding Source Buttons for the Clients repeat the above steps for the Clients. c. Assign Audio and Video Inputs for the TGM-100 sources. On the Setup tab, select the appropriate S12 sources for the TGM-100s. In our example, the assignments would look like this:
This display, along with the S12 Setup display, show that when the TGM-100 Server is selected, the Zone will play the audio from TGMServer which is the first Audio Input. The Zone will display the component video from the TGM-100 Server, which displays the TV UI and the Movies. And the VIA1 panels will have the Composite video from the TGM-100 Server that displays the Elan Touch Panel UI, which is Video Input 1. The Clients information is also displayed. d. Transfer to the VIA1 panel. When a TGM-100 Source is selected on the VIA1 panel, displays such as the following will be shown. For more information on the displays, see the Sunfire TGM-100 Installation / Users Guide.
Page 90 of 98
Page 91 of 98
e. Settings Button on TGM-100 Source Page When exiting from the TGM-100 Elan Touch Panel UI, there is a button named Settings:
Normally, this button is not needed by the end user. It provides the user the ability to switch the TGM-100 audio output to Stereo or Surround. It also provides a mechanism to Reset the Elan Touch Panel UI and to Reset the TV UI. Pressing Settings will bring up this display:
Page 92 of 98
This is part of the template for the TGM-100. Output 1 refers to the Server; Output 2 refers to Client 1; Output 3 refers to Client 2, etc. Selecting one of the Output buttons will bring up this display:
The commands under these buttons are specific to the Output selected. If Output 1 was selected, then these buttons contain commands that will affect the TGM-100 with Output 1 (ie, Unit ID 1 or Number 1, ie, the Server); if Output 2 was selected, then these buttons contain commands for TGM-100 with Unit ID 2 or Number 2, ie, Client 2. And so forth for the other Outputs. The installer may delete the Output buttons that are not relevant to the TGM-100 on the Source Button.
5. VIA1 Panel programming using IR Controlled TGM-100s The S12 setup is the same. There is no need for adding Serial Drivers
Page 93 of 98
VIA! Tools 10.3.0.8 Release Notes since IR Control will be used. The only difference is when adding the Source Button on the Layout tab. Instead of using Serial two-way (w/ feedback), use Special Component. a. Adding TGM-100 Source Button for IR control On the Layout tab, select Add/Remove/Save, and then select Special Component. When the display comes up, select the Sunfire TGM-100 and click OK.
The XP84 Wireless Panel uses the Ethernet Interface to the TGM-100; it does not use IR or Serial Commands. HOWEVER, IT DOES NEED TO HAVE THE SUNFIRE TGM-100 TWOWAY DRIVER CONFIGURED ON A SS1 OR SC1! THIS IS NEEDED BECAUSE THE IP ADDRESS WHICH IS NEEDED BY THE XP84 IS STORED AS PART OF THE DRIVER CONFIGURATION. AND THE TGM-100 SOURCE IS ADDED TO THE WIRELESS PANEL AS IF IT WERE A SERIAL CONTROLLED SOURCE. If the Project already has the two-way driver configured, nothing more needs to be done. If not, then the user needs to add a dummy SS1 or SC1 to the Project, and then configure a driver on the SS1 or SC1. The Page 94 of 98
VIA! Tools 10.3.0.8 Release Notes driver does need to be downloaded, only its configuration data set up. NOTE: If there is an unused driver slot on an existing SS1, the TGM-100 driver could be added there; but it is recommended to add a dummy SS1 or SC1 to avoid confusion about which is real and which is a dummy. a. Add the TGM-100 Source button Add the Source button the same way as the Source Button was added to the VIA1 panel for Serial Control: Layout Tab, Add/Save/Remove, Serial two-way(w/ feedback). The Select TW Driver window will be shown with the real SS1s and SC1s and the dummy SS1s.
Select the appropriate TGM-100 driver and click OK. b. Select Source for TGM-100 Source Button As was done for the VIA1 panel programming, select the S12 Source for the TGM-100 Source Button.
Page 95 of 98
VIA! Tools 10.3.0.8 Release Notes c. Transfer to the Zone SS1 and Wireless Panel Transfer to the Zone SS1 and the Wireless Panel in the normal fashion.
7. OLE 2 / OLE XL Programming uses Serial Controlled TGM-100 The OLE 2 and the OLE XL can be used to control the Music portion of the TGM-100. It will allow the user to browse the Music Library by Artist, Album, Genre, etc and select the desired selections. The user will be able to Pause, Play, Skip Forward/Reverse, etc. The control and feedback is done using the Serial Driver for the TGM100. Start on the OLE Source tab. a. Enter a Source Name b. Assign an Icon c. Import a Template Click on the Import button in the Templates column. In the Open dialogue window, select the folder Sunfire, then TGM-100, then Serial Control. That will produce this window:
Currently there are templates for the Server, Client 1, and Client 2. Select the appropriate template for the TGM-100 and OLE type and click Open.
Page 96 of 98
d. In addition to static buttons on the OLE XL, the template has one page programmed with Play, Stop, Pause, Track Up, Track Down, Repeat, and Shuffle:
e. Assign the TGM-100 two-way driver In the Two Way column, click on the arrow button to assign the twoway driver to this source. Select the appropriate TGM-100 driver, and click OK.
Page 97 of 98
VIA! Tools 10.3.0.8 Release Notes On the Setup Tab, select the Audio Source for each TGM-100. There is no Video source to select. As an example, see this display:
Page 98 of 98