0% found this document useful (0 votes)
349 views6 pages

Sieve Analysis Graph

This document summarizes the results of a particle size analysis test on a soil sample: 1) Sieve analysis was performed on the sample using sieves with mesh sizes ranging from 4.75mm to 0.075mm. The percent of sample retained and passing each sieve is reported. 2) Hydrometer analysis was also conducted on the portion of the sample passing the #200 sieve (0.075mm). Hydrometer readings were taken over time and corrected to determine percent finer values. 3) The sieve and hydrometer data were used to construct a particle size distribution curve showing the relationship between particle size and percent finer for the soil sample.

Uploaded by

Roa Mae Julaton
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
349 views6 pages

Sieve Analysis Graph

This document summarizes the results of a particle size analysis test on a soil sample: 1) Sieve analysis was performed on the sample using sieves with mesh sizes ranging from 4.75mm to 0.075mm. The percent of sample retained and passing each sieve is reported. 2) Hydrometer analysis was also conducted on the portion of the sample passing the #200 sieve (0.075mm). Hydrometer readings were taken over time and corrected to determine percent finer values. 3) The sieve and hydrometer data were used to construct a particle size distribution curve showing the relationship between particle size and percent finer for the soil sample.

Uploaded by

Roa Mae Julaton
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 6

WT, gm 855

Sieve Wt Ret %Retained


Number gm gm

4 267 31.2280701754386
10 310 36.2573099415205
20 174 20.3508771929825
40 55 6.4327485380117
60 20 2.33918128654971
100 14 1.6374269005848
200 13 1.52046783625731
Pan 4 0.467836257309941

SUM 857

Weight. of Soil (Ws) 4


Correction Factor 1

Elapsed Time (min) Temperature (C)

2 20
5 20
8 20
15 20

Elapsed Time (min) Corrected Hydrometer Reading (mm)


2 5
5 5
8 5
15 4
Acc %Ret Sieve Size Passing
(mm) (%)

31.22807 4.75 68.77193


67.4853799415205 2 32.5146200584795
87.836257134503 0.85 12.163742865497
94.2690056725147 0.425 5.73099432748535
96.6081869590644 0.25 3.39181304093564
98.2456138596492 0.15 1.75438614035085
99.7660816959065 0.075 0.233918304093535
100.233917953216 -0.233917953216405

Temp Correction (Ct) Hydrometer Reading (mm) Corrected Hydrometer Reading (mm)

0 6 5
0 6 5
0 6 5
0 5 4

K L (cm) D
0.01365 15.3 0.0377540345526144
0.01365 15.3 0.0238777480093915
0.01365 15.3 0.0188770172763072
0.01365 15.5 0.013875635120599
Particle-sized Distribution Curve - Sieve and H
$80.00
$70.00
$60.00
Percent Finer (%)

$50.00
$40.00
$30.00
$20.00
$10.00
$0.00
100 10 1 0.1
Sieve Analysis (mm)

Percent Finer (%)

125
125
125
100

Percent Finer in Suspension (%) Adjusted Percent Finer in Solution (%)


125 0.09375
125 0.09375
125 0.09375
100 0.075
ed Distribution Curve - Sieve and Hydrometer Analysis

Sieve Analysis
Hydrometer Analysis

1 0.1 0.01 0.001


Sieve Analysis (mm)

L (cm) L/t K D Adjusted Percent Finer (%)


0.075 0.233918304093578
15.3 7.65 0.01365 0.037754034552614 0.09375
15.3 3.06 0.01365 0.023877748009392 0.09375
15.3 1.9125 0.01365 0.018877017276307 0.09375
15.5 1.0333333333 0.01365 0.013875635120599 0.075
Hydrometer Ana

Sieve Analysis
Hydrometer Analysis

Percent Finer (%)

Sieve Size (mm


Hydrometer Analysis

0.215

0.195

0.175

0.155

0.135

0.115

0.095

0.075

Sieve Size (mm)