MOP - Upgrade DCI-PE-02 ASR920
MOP - Upgrade DCI-PE-02 ASR920
Revision Record
Date Revised Version Change description Author
1
Table of Contents
Background...................................................................................................................................3
Work Information.............................................................................................................................3
1.1.1 Site Address.................................................................................................................3
1.1.2 Work Schedule...............................................................................................................3
1.1.3 Activity Time Plan...........................................................................................................3
1.1.4 Software Requirement......................................................................................................3
Network Topology............................................................................................................................3
Pre-Activity....................................................................................................................................4
Before & After................................................................................................................................4
Detail Upgrade Procedure..................................................................................................................7
Rollback Procedure..........................................................................................................................7
Appendix......................................................................................................................................7
2
Background
The purpose of this document is to provide the information and procedure upgrade the ASR920.
Work Information
1.1.1 Site Address
No. Hostname Platform IP Address Site Name
1. DCI-PE-02 ASR-920-24SZ-M 10.255.102.27 Data Center Indonesia
Site Address and Hostname Information
Figure 1. Topology
3
Pre-Activity
Step task Owner(s) Status Remark
1 copy scp:asr920-universalk9_npe.16.09.03.SPA.bin bootflash: Multipolar The images is already uploaded to the
Jumbox server, So we can copy from
there, Please make sure the bootflash
have a free space to store the image
2 copy scp:asr920_15_6_43r_s_rommon.pkg bootflash: Multipolar The rommon is already uploaded to the
Jumbox server, So we can copy from
there, Please make sure the bootflash
have a free space to store the rommon
3 dir bootflash: Multipolar Check the files is already transferred to
the bootflash
4 verify /md5 bootflash:asr920-universalk9_npe.16.09.03.SPA.bin Multipolar Check the file integrity, Will be showing
5ca8a4a38b6b3cdd8c4d125339317e4b DONE if the security is match
5 verify /md5 bootflash:asr920_15_6_43r_s_rommon.pkg 99ac9ece7eb6c2f1d19727bd3f5653ca Multipolar Check the file integrity, Will be showing
DONE if the security is match
4
show interfaces description
show ip int brief
show run
show log
dir bootflash:
show sdm prefer current
2 Show xconnect all Multipolar L2 & L3 service check
Show l2vpn service xconnect all
Show mpls l2transport vc
Show mpls traffic-eng tunnels role all
Show int des | i UPLINK
show int des | i DOWNLINK
Show arp
Show arp vrf dci-corp-linknet01-fo
Show vrf
Show ip ospf neighbor
Show mpls ldp neighbor
Show ip mroute
Show ip mroute vrf tgl-ftth-iptv-fo
Show bgp all summary
3 Ping 192.168.227.41 Multipolar Reachability check
Ping 192.168.229.49
5
ping vrf dci-gcp-it01-fo 169.254.44.225
ping vrf dci-gcp-it01-fo 169.254.176.25
6
Detail Upgrade Procedure
Step task Owner(s) Status Remark
1 configure terminal Multipolar Enter configuration mode
2 boot system bootflash:asr920-universalk9_npe.16.09.03.SPA.bin Multipolar Set boot file system
3 end Multipolar Exit configuration mode
4 sh run | i boot Multipolar Check boot config
5 configure terminal Multipolar Enter configuration mode
6 no boot system bootflash:asr920-universalk9_npe.03.17.03.S.156-1.S3-std.bin Multipolar Remove the previous boot file system,
7 Line vty 0 15 Multipolar enter to line vty config
8 access-class 1 in vrf-also Multipolar Access-list applied for all VRF
9 end Multipolar Exit configuration mode
10 sh run | i bootfl Multipolar Check boot config, Make sure only one
boot system for 16.09.03
11 show run | sec line Multipolar Check line vty config, Make sure it’s
already applied
12 write memory Multipolar Save configuration
13 upgrade rom-monitor filename bootflash:asr920_15_6_43r_s_rommon.pkg all Multipolar Upgrade the rommon
14 reload Multipolar Reload for upgrade
Rollback Procedure
If needed
Appendix
#Capture/Output/Files Remark