0% found this document useful (0 votes)
148 views

Tromp Curve v2

This document summarizes the results of a particle size analysis test performed on a cement product using laser diffraction. It includes a table with 27 sieve sizes ranging from 100um to 2um, showing the cumulative percentage passing and distribution metrics for fines, feed, and rejects. A graph plots the cumulative passing percentages versus the sieve sizes. Additional calculations and metrics are provided on a second page, including the fines cumulative yield, circulation load, bypass percentages, and d25, d50, and d75 values.

Uploaded by

safwat hassan
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
148 views

Tromp Curve v2

This document summarizes the results of a particle size analysis test performed on a cement product using laser diffraction. It includes a table with 27 sieve sizes ranging from 100um to 2um, showing the cumulative percentage passing and distribution metrics for fines, feed, and rejects. A graph plots the cumulative passing percentages versus the sieve sizes. Additional calculations and metrics are provided on a second page, including the fines cumulative yield, circulation load, bypass percentages, and d25, d50, and d75 values.

Uploaded by

safwat hassan
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 4

Version Date Who Comments

1.0 12/1/2004 Mario Interlenghi CTEO milling group version.


Karim El Hajoui
Cédric Richard

2.0 4/25/2007 Olivier Bernard TCEA version for Excel 2000


1
2
3
#

4
Comments
CTEO milling group version.

TCEA version for Excel 2000


Logo changed to TCEA
Plot (fx-ax) vs (fx-rx): regression line connected to cells S40:S41 and T40:T41
Plot (fx-ax) vs (fx-rx): names "Droite_RA_1" and "Droite_RA_2" removed
2 and 3 done to give the possibility to copy the tab several times in the spreadsheet
without creating problems with the names
There remains the necessity to adjust manually the data cells for this plot within the range
P9:Q37, when the number of sieves varies
Calculations for plotting the cumulative fines yield (range R49:R77): the formula used was
incorrect, changed to "1-R/A*r/a"
TROMP CURVE Page 1

The sieve sizes must imperatively be sorted in descending order Enter in cells shaded yellow

Works Martres DATE : 6/14/2001


Mill Broyeur BK 3 Product CEM I 52,5 R (4330 cm²/g)
Separator Séparateur Laser type Malvern TCEA in ethanol

Mesh % cumulative passing dx P(x) % R/A


(µm) Fines Feed Rejects fraction
1 100.00 99.98 86.17 81.66 94.9 µm 98.7% 0.779
2 90.00 99.80 82.89 77.50 84.9 µm 98.0% 0.769
3 80.00 99.44 78.80 72.29 75.4 µm 96.8% 0.756
4 71.00 98.81 74.26 66.49 66.9 µm 95.2% 0.770
5 63.00 97.82 69.42 60.50 59.4 µm 93.1% 0.802
6 56.00 96.41 64.52 54.74 50.2 µm 89.5% 0.762
7 45.00 92.48 55.83 44.56 42.4 µm 85.2% 0.736
8 40.00 89.62 51.41 39.58 37.9 µm 81.8% 0.726
9 36.00 86.66 47.68 35.56 33.9 µm 78.1% 0.586
10 32.00 82.97 43.82 31.58 29.9 µm 73.5% 0.797
11 28.00 78.43 39.87 27.78 26.5 µm 68.7% 0.765
12 25.00 74.40 36.88 25.11 23.5 µm 63.9% 0.757
13 22.00 69.80 33.90 22.65 21.0 µm 59.7% 0.755
14 20.00 66.40 31.92 21.13 19.0 µm 56.3% 0.752
15 18.00 62.76 29.95 19.71 17.0 µm 52.9% 0.752
16 16.00 58.85 27.98 18.38 15.0 µm 49.5% 0.749
17 14.00 54.60 25.97 17.12 13.0 µm 47.3% 0.754
18 12.00 49.96 23.88 15.86 11.0 µm 46.2% 0.757
19 10.00 44.79 21.61 14.52 9.5 µm 46.4% 0.766
20 9.00 41.96 20.38 13.78 8.5 µm 46.6% 0.758
21 8.00 38.93 19.04 12.98 7.1 µm 47.8% 0.772
22 6.30 33.18 16.50 11.39 5.6 µm 48.8% 0.779
23 5.00 28.15 14.26 9.94 4.5 µm 49.2% 0.783
24 4.00 23.85 12.34 8.68 3.8 µm 49.7% 0.783
25 3.60 22.01 11.51 8.13 3.0 µm 50.9% 0.786
26 2.50 16.58 9.01 6.43 2.2 µm 53.4% 0.776
27 2.00 13.92 7.70 5.51
28
29 Average (R/A )= 0.768

100
90 Fines
80 Feed
Rejects
% Cumulative Passing

70
60
50
40
30
20
10
0
1 10 100

Mesh (µm)
TROMP CURVE Page 2

Works Martres DATE : 6/14/2001


Mill Broyeur BK 3 Product CEM I 52,5 R (4330 cm²/g)
Separator Séparateur Laser type Malvern TCEA in ethanol

Fines cumulative CIRCUL. LOAD 331% Imperfection Normalized Raw


yield 49.6% BY PASS 46.2% 0.38 0.58
ACUITY LIMIT 16 µm d 25 (µm) 21 µm 10 µm
CORRECTED BY PASS 60.2% d 50 (µm) 29 µm 17 µm
NORM. IMPERFECTION 0.38 d 75 (µm) 43 µm 30 µm

1
1 10 100

Number of points on the left side of the curve (optional) 11

You might also like