0% found this document useful (0 votes)
98 views9 pages

Sensedge Mini Technical Specifications - 2021

The Sensedge Mini is an air quality monitoring device that accurately measures PM2.5, TVOC, CO2, temperature, and humidity using various sensor technologies, and has multiple power and connectivity options including Wi-Fi, Ethernet, and Modbus; it provides real-time air quality data logging and is designed for building owners and managers to monitor indoor environmental conditions. The device has a 1-year warranty and is expected to last 5-7 years with user-replaceable sensor modules that require recalibration.

Uploaded by

FELIX DOSS
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
98 views9 pages

Sensedge Mini Technical Specifications - 2021

The Sensedge Mini is an air quality monitoring device that accurately measures PM2.5, TVOC, CO2, temperature, and humidity using various sensor technologies, and has multiple power and connectivity options including Wi-Fi, Ethernet, and Modbus; it provides real-time air quality data logging and is designed for building owners and managers to monitor indoor environmental conditions. The device has a 1-year warranty and is expected to last 5-7 years with user-replaceable sensor modules that require recalibration.

Uploaded by

FELIX DOSS
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Sensedge Mini

Technical Specifications
(SE-200 & SE-200P)

Product Overview

The Sensedge Mini provides real-time, accurate measurements of PM2.5, TVOC, CO2, and O3*
concentrations, as well as temperature and relative humidity readings. With multiple power,
connectivity, and installation options, the Sensedge Mini is made to the satisfaction of
building owners, facility managers, tenants, and employees.

* Ozone measurement available with KM-207 module.


Particulate
Matter Sensor
Specification
01
Mass concentration accuracy Mass concentration
for PM2.5 size range
0 to 30 μg/m³ : ±3 μg/m³ PM2.5 0.3 to 2.5 μg/m³
30 to 1000 μg/m³ : ±10 % m.v. PM10 0.3 to 10.0 μm

Mass concentration range Sensor output resolution


0 to 1,000 μg/m³ 1 μg/m³

Sensor technology Typical response time


Laser particle sensor (Light scattering) ≤10 s

Recommended lifetime Calibration


High pollution concentration (> 200 μg/m³) Calibrated against standardized
1.3 years aerosol mix
Low pollution concentration (< 100 μg/m³)
2 years
TVOC
Sensor
Specification
02
Target gas profile Measurement range
Complex mixture of 22 VOCs1 as defined by 0 - 60000 ppb
Molhave et al.

Accuracy Sampling process


±15 % ±8 ppb Diffusion

Calibration Sensor output resolution


Calibrated against ethanol 1 ppb

Sensor technology Typical start-up time


Multi-pixel metal oxide sensor (MOx) 0.4 ms

1 n-Hexane, n-Nonane, n-Decane, n-Undecane ,1-Octane, 1-Decene, Cyclohexane, m-Xylene, Ethylbenzene,


1,2,4-Trimethylbenzene, n-Propylbenzene, a-Pinene, n-Pentanal, n-Hexanal, Iso-propanol, n-Butanol, 2-Butanone,
3-Methyl-3-butanone, 4-Methyl-2-pentanone, n-Butylacetate, Ethoxyethylacetate, 1, 2-Dichloroethane
CO2
Sensor
Specification
03
Target gas Measurement range
CO2 400 to 2,000 ppm1
Up to 10,000 ppm extended range2

Accuracy3 Typical response time


±3 % m.v. ±50 ppm 2 minutes by 90 %

Sensor technology Sensor output resolution


Non-dispersive infrared (NDIR) 1 ppm

Recommended lifetime
15+ years

1 Extended exposure to concentrations below 400 ppm may result in incorrect operation of ABC algorithm and should be
avoided.
2 Sensor provides readings in the extended range but the accuracy may be lower than that specified in the table.
3 Accuracy is specified over operating temperature range. Specification is referenced to certified calibration mixtures.
Uncertainty of calibration gas mixtures (±2% currently) is to be added to the specified accuracy for absolute
measurements.
Ozone Sensor
Specification
(Available with
04
KM-207 module)

Target gas Measurement range


O3 20 to 2,000 ppb

Accuracy Typical response time


±10 % < 90 s

Sensor technology Sensor output resolution


Electrochemical 10 ppb

Recommended lifetime Interference gas


2 years NO2, CL2, H2, CO
Temperature
Sensor
Specification
05
Measurement range Accuracy
-20 - 100 °C ±1 °C

Long term drift1 Typical response time2


<0.03 °C/y >2 s

Sensor technology Sensor output resolution


Digital sensor 0.01 °C

Recommended lifetime
10 years

1 Typical value for operation in normal RH/T operating range. Higher drift values may occur due to contaminant
environments with vaporized solvents, out-gassing tapes, adhesives, packaging materials, etc.
2 Temperature response times strongly depend on the type of heat exchange, the surrounding surface and the airflow in
the final application environment.
Humidity
Sensor
Specification
06
Measurement range Accuracy
0 - 99 % RH ±5 % RH

Long term drift Typical response time1


<0.25 % RH/yr >8 s

Sensor technology Sensor output resolution


Digital sensor 0.01 % RH

Recommended lifetime
10 years

1 Humidity response times strongly depend on the surrounding surface and the airflow in the final application
environment.
General
Device
Specifications
07
Calibration Operating conditions
Calibration via hot-swappable sensor Operational temperature: 0 - 50 °C
modules Operational humidity: 5 to 95 %RH,
non-condensing

Data storage & logging Dimensions


Frequency of readings (Log interval): Length: 155 mm (6.1 in)
1 minute, 1 hour, 1 day Width: 129 mm (5.1 in)
Data push interval: 1 minute1 Height: 34 mm (1.3 in)
Onboard memory: 1 hour of data

Weight Warranty & durability


370 g (0.82 lbs) Standard warranty: 1 year2
Expected lifespan: 5 to 7 years

1 Customizable upon request


2 Optional extended warranty with contract
Power and
Connectivity
Options
08
Installation Wi-Fi
Surface mount 2.4 GHz 802.11 b/g/n
Drywall mount Security supported: 64/128 WEP,
Electrical box mount WPA-PSK, WPA2-PSK, WPA, WPA2
Ceiling mount Personal

Ethernet Modbus (RS-485)


IEEE 802.3 RS-485 Modbus/RTU
Data rate: Up to 100 Mbps

Integration Power
BACnet/IP 100 - 240 V AC Via USB-C (5V 1.8A DC)
Local and cloud MQTT
Open API 12 - 30 V DC Via direct wiring
PoE (Available for model SE000200P)
IEEE 802.3af (PoE), Class3
IEEE 802.3at (PoE+), Class3
1 Total length of cabling up to 100 meters. However,
we don’t recommend using cables longer than 50m PD maximum power ≤ 10 W
to guarantee the stability of power and data PSEs: Midspan & endspan supported
transmission. Cable: Cat5 (Cat5e, Cat6, and Cat6a)1

Get in touch with us!


www.kaiterra.com [email protected]

You might also like