FD-Q20C Datasheet

This document provides specifications for the FD-Q20C sensor main unit, which can measure flow rates of various liquids in pipes with diameters between 1/2" to 3/4" and temperatures from 0 to 85°C. The sensor unit has a dual row LED display, integrated data storage, IP65/IP67 rating, and M12 power/I/O connector. It can output flow rate and totalized flow data, with selectable response times from 0.5 to 60 seconds.

Uploaded by

mwrsbs
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
137 views

FD-Q20C Datasheet

This document provides specifications for the FD-Q20C sensor main unit, which can measure flow rates of various liquids in pipes with diameters between 1/2" to 3/4" and temperatures from 0 to 85°C. The sensor unit has a dual row LED display, integrated data storage, IP65/IP67 rating, and M12 power/I/O connector. It can output flow rate and totalized flow data, with selectable response times from 0.5 to 60 seconds.

Uploaded by

mwrsbs
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Data 

Sheet

FD­Q20C
Sensor Main Unit 15A/20A Type

SPECIFICATIONS

Model FD­Q20C

Supported pipe diameter 1/2" (15 A), ø18 to ø23 (mm)
3/4" (20 A), ø23 to ø28 (mm)

Supported pipe materials Metal pipe/Resin pipe*1

Supported fluids Various liquid [i.e. water (including DI), oils, chemicals, etc.]*1

Supported fluid temperature 0 to 85°C 32 to 185°F (No freezing on the pipe surface)*2

Maximum rated flow 1/2" (15 A): 60 L/min, 15.9 G/min
3/4" (20 A): 100 L/min, 26.4 G/min

Zero cut flow rate 2.5 L/min (Default)*3

Display method Status indicator, output indicator, dual row display with 4­digit, 7 segment LED, stability level indicator

Display update cycle Approx. 3 Hz

Display resolution 0.1/ 1 (Default : 0.1) (L/min)

Response time 0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s

Repeatability 0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S.*4(Specific to sel
ected response time))

Hysteresis Variable

Integrated flow unit display 0.1/ 1/ 10/ 100/ 1000 (Default : 1) (L)

Integrated flow data storage cycle Save to memory every 10 seconds

Memory backup EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more)

Power I/O connector M12 4­pin connector

Input/Output (Selectable) Output (ch.1/ch.2) Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used),


NPN/PNP setting switchable,open collector output 30 V or less, max. 100 mA/ch., residual voltage 2.5 V or less*5

Analog output (ch.1/ch.2) 4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 Ω or less*5

External input (ch.2) Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used),
short­circuit current 1.5 mA or less, input time 20 ms or more*5

Power source Power supply voltage 20 to 30 VDC , ripple (P­P) 10% max, Class2/LPS

Current consumption 100 mA or less (Load current excluded)*6

Protection circuit Power supply reverse connection protection, power supply surge protection,
each output short­circuit protection, each output surge protection

Environmental resistance Enclosure rating IP65/IP67 (IEC60529)

Ambient temperature ­10 to +60 °C 14 to 140 °F (No freezing)

Relative humidity 35 to 85 % RH (No condensation)

Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance 100 m/s2, 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material Sensor main unit PPS/PES/PBT/SUS303/SUS304/SUSXM7

Sensor surface Rubber

Mounting bracket SUS304/PA/SUSXM7

Weight Approx. 400 g (including mounting bracket)
*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable on certain non­standard pipes (i.e. lined pipes)
*2 Contact KEYENCE when the temperature of the pipe is greater than 85°C 185°F
*3 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate.
*4 This specification is valid when the flow velocity distribution is stable. This value does not take into account the effects of pulsation or fluctuations in flow velocity distribution due to facility factors. Convert the
F.S. (full scale) listed in the table according to the rated flow range.
*5 IO­Link: Compatible with Specification v1.1 / COM2 (38.4 kbps) The setting file can be downloaded from the KEYENCE website. If using the unit in the environment where downloading the file is not possible
via internet, contact your nearest KEYENCE office. IO­Link is either registered trademarks or trademarks of PROFIBUS Nutzerorganisation e.V. (PNO)
*6 When including the loads, please add 200 mA to this value.

KEYENCE AMERICA 1­888­539­3623(Toll Free) https://www.keyence.com/ 2020/05/29 Page:1/2


Data Sheet

Dimensions

* Download CAD file or product manual for larger image/text and more detail.

FD­Q10C_Q20C_Q32C_Q50C_dimension01.gif

FD­Q10C_Q20C_Q32C_Q50C_dimension02.gif