You are on page 1/ 22

Meters and Energy Cost Allocation

Electronic water meter


WFK636.. WFW636.., WMK636.., WMW636..

Electronic, mains-independent meter for measuring consumption of cold and


hot water
● Continuous flow Q3 = 2.5 m3/h or 4 m3/h
● Available as screw-type meter WF.636.. or measuring capsule meter WM.636..
● Single-jet impeller type (screw-type water meter) or multi-jet impeller meter
(measuring capsule water meter)
● Parallel transmission of AMR and walk-by telegrams
● Communication in S-mode or C-mode
● OMS compliant AMR telegrams in C-mode
● Any mounting position (horizontal or vertical)
● Operating and configuration software to configure specific devices via the meter's
optical interface
● Leakage detection
● Displays cumulated consumption and due date consumption

A6V12128928_en--_b
2022-08-16
Application
The screw-type cold (WFK..) and hot water (WFW..) meters as well as cold water measuring
capsule (WMK..) The hot water meter (WMW..) is compact in design and used for measuring
physical cold or hot water consumption. The meter consists of a flow element and a totalizer.

Functions
The compact, single-jet impeller type meters (screw-type water meter) or multi-jet impeller
meter (measuring capsule water meter) is used for drinking water (cold or hot) and consists
of a flow element and a totalizer with LCD display.
In most cases, the single-pipe connection piece (EAT) is already present and embedded in
the masonry.
The totalizer can be rotated 360° on the fitting.
The flow measuring section on the screw-type water meter is made of brass and includes a
sieve at the input to collect larger dirt particles.
The water flows through the flow measuring section to drive the single-jet impeller. The
speed is sampled inductively via coils to provide low wear and long-term stable measuring.
Incorrect direction of flow is detected and indicated by an error message on the display.
The resulting volume is added up, displayed and can be transmitted via RF to a data
processing system. A long-life battery powers the processor for up to 10 years with 1 year of
reserve capacity.

Dry rotor
The water meter is a dry rotor with high pressure resistance.
This prevents the totalizer from exposure to the medium and protects against dirt. The
impeller has double bearings and the meter is protected against external magnetic influence
to guarantee the highest accuracy and security under all installation conditions.

Infrared interface
The water meters can be read out on site via optical close-range interface. The meter is read
out and configured with the WFZ.IRDA-USB optical reading head and associated
configuration software.

Communication
The water meter sends parallel AMR and walk-by data telegrams in S-mode or C-mode. You
can switch from S-mode to C-mode with the configuration software. RF is activated using the
WFZ.PS tool, ACT50 software or automatically after consuming 50 liters.
The AMR telegrams are automatically collected and saved by a network node WTT662.. or
WTT561... RF converter. The walk-by telegram can be collected during a walk by a the
mobile data logger. The customer can remotely read out all plant consumption data.

Leakage detection
The meter generates an alarm if detects flow (between 4 and 5 liters per hour depending on
the version) over a long period (factory setting of 24 hours).
A leak is indicated on the display by 'LEAC'. At the same time, an error message is
transmitted via RF.
The threshold value can be adapted to between 1 and 24 hours using the configuration
software.

2
Smart Infrastructure A6V12128928_en--_b
2022-08-16
Tampering
The meters are tested against electromagnetic and magnetic disturbances
per EN ISO 4064-2.

Function check
The flow is acquired continuously. The volume is displayed in real time. Any errors are
immediately displayed. Meters conducted the following self-tests:
● Leakage detection
● Reverse flow
● Error detection

Display
Water consumption is continuously cumulated. The current state is stored at 11:59 PM am
on the next due date.
The due date is factor set to 31.12, but can be configured with the ACT50 software.
The water meter calculates a checksum when saving the annual consumption. Self-readers
can notify the responsible office together with the read out on the due date to verify the
correct read out of the display. The stored due date remains in place for one year.

The water meter has a display loop. The following data can be read from the water meter's
displayr:
● Error code
● Error date
● Current total consumption
● Due date
● Due date value
● Checksum
● RF mode

These segments appear only when a device


fault occurs.

They can be individually activated or


deactivated with the configuration software.

3
Smart Infrastructure A6V12128928_en--_b
2022-08-16
The following parameters can be read out and/or configured using the configuration software
via the IrDA interface:

Read out only:


General
● Serial number
● Mounting place
● SW version
● Medium
● Commissioning date
● Battery life
● Stock number
● Leakage detection
● Device date
● Error date
● Error code

Device information
● Device name/password
● Current flow rate

Meter states
● Current meter state
● Reverse volume indication
● Last due date
● Meter state on last due date
● Next due date
● Maximum flow rate
● Leakage

Statistical values
● 13 monthly values

RF settings
● RF mode
● RF system
● Walk-by readout type (S-mode only)
● Walk-by transmission delay (S-mode only)
● Walk-by transmission timeframe (S-mode only)
● Walk-by transmission-free days (S-mode only)

Configuration:
General
● Mounting place
● Display loop
● Leakage detection

4
Smart Infrastructure A6V12128928_en--_b
2022-08-16
Due date
● Next due date

Device information
● Device name/password

RF settings
● RF mode
● RF system
● Walk-by readout type (S-mode only)
● Walk-by transmission delay (S-mode only)
● Walk-by transmission timeframe
● Walk-by transmission-free days (S-mode only)

Error messages

Error code Error description Measures/notes

LEAC Leakage in the system Check piping, eliminage leakage.


The error automatically resets once the
leakage is eliminated.

0 Flow direction negative Check meter installation / flow direction

2 Operating hours expired Replace the device during the next service
appointment.

3 Hardware error Replace the device!

4 Permanently stored errorr Replace the device!

b Communicated too much in The lock is automatically lifted each month!


the month via OPTO

d Too much flow Check installation conditions!


Eventually replace by a meter with a larger Q3.

f The device lost powered for Replace the device!


a short period.
The entire configuration is
lost.

5
Smart Infrastructure A6V12128928_en--_b
2022-08-16
Technical design

Pressure drop characteristic


Q3 2.5 4
1.0

0.1

0.01

0.001

0.0001
0.01 0.1 1 10

RF features in S-mode
The following values are transmitted by default in the RF telegram in S-mode:

Electronic water meters in S-mode have the following features:

RF system Parallel transmission of data ● AMR


telegrams ● Walk-by

Transmission delay (Offset) Time delay for sending out telegrams after the due date
Time delay for sending out telegrams after the start of the
month in days (Default = 0 days)

Transmission-free days A maximum of 2 days of the week can be defined as


transmission-free days. At least 1 day of the week must be
set (Default = Sunday)

Transmission response

AMR telegrams Every 4 hours, 24 hours a day, 365 days a year


Data telegrams with the current consumption value and due
date value as well as monthly telegram with consumption
value at the end of the last month

Walk-by telegrams Every 128 seconds, 10 hours a day (from 8:00 am to 6:00
pm)

Readout type Monthly: 4 readout days as of the


first of each month
Annually: 48 readout days, once
a year by due date

Transmission-free days Monthly: Saturday and Sunday


Annually: Sunday

Current consumption value, due date value, due date as


well as end of month values for the last 13 months

6
Smart Infrastructure A6V12128928_en--_b
2022-08-16
RF features in C-mode
The following values are transmitted by default in the RF telegram in C-mode:

Electronic water meters in C-mode have the following features:

RF system Parallel transmission of data ● AMR


telegrams ● Walk-by

Increase RF output (typically 10 dBm)

AMR telegrams Every 7.5 hours, 24 hours a day, 365 days a year

Data telegram with current consumption value

Walk-by telegrams Every 112 seconds, 10 hours a day (from 8:00 am to 6:00
pm)
365 days a year

Current consumption value, due date value, due date as


well as end of month values for the last 13 months

Change of mode
You can switch between S-mode and C-mode any time with the help of the configuration
software and the infrared read head WFZ.IRDA-USB.

Type summary

Features of the water meters listed below:

Design Screw-on water meter: Single-jet dry runner


Measuring capsule meter: Multi-jet dry runner

Rated pressure PN 16

Communication Wireless M-bus, S-mode

Due date 31.12.

Display m3

Screw-on cold water meter in S-mode

Designation Ordering number Type

Q3 = 2.5 m3/h, mounting S55560-F116 WFK636.D080


length 80 mm, connecting
thread G¾", up to 30 °C

Q3 = 2.5 m3/h, mounting S55560-F117 WFK636.D110


length 110 mm, connecting
thread G¾", up to 30 °C

Q3 = 4 m3/h, mounting length JXF:WFK636.E130 WFK636.E130


130 mm, connecting thread
G1", up to 30 °C

7
Smart Infrastructure A6V12128928_en--_b
2022-08-16
Screw-on cold water meter in C-mode

Designation Ordering number Type

Q3 = 2.5 m3/h, mounting S55560-F120 WFK636.D08C


length 80 mm, connecting
thread G¾", up to 30 °C

Q3 = 2.5 m3/h, mounting S55560-F121 WFK636.D11C


length 110 mm, connecting
thread G¾", up to 30 °C

Q3 = 4 m3/h, mounting length JXF:WFK636.E13C WFK636.E13C


130 mm, connecting thread
G1", up to 30 °C

scew-on hot water meter in S-mode

Designation Ordering number Type

Q3 = 2.5 m3/h, mounting S55560-F118 WFW636.D080


length 80 mm, connecting
thread G¾", up to 90 °C

Q3 = 2.5 m3/h, mounting S55560-F119 WFW636.D110


length 110 mm, connecting
thread G¾", up to 90 °C

Q3 = 4 m3/h, mounting length JXF:WFW636.E130 WFW636.E130


130 mm, connecting thread
G1", up to 90 °C

Screw-type hot water meters in C-mode

Designation Ordering number Type

Q3 = 2.5 m3/h, mounting S55560-F122 WFW636.D08C


length 80 mm, connecting
thread G¾", up to 90 °C

Q3 = 2.5 m3/h, mounting S55560-F123 WFW636.D11C


length 110 mm, connecting
thread G¾", up to 90 °C

Q3 = 4 m3/h, mounting length JXF:WFW636.E13C WFW636.E13C


130 mm, connecting thread
G1", up to 90 °C

8
Smart Infrastructure A6V12128928_en--_b
2022-08-16
Chilled water mechanical capsule counter in S-mode

Designation Ordering number Type

The cold water meter for the JXF:WMK636.DIS00 WMK636.DIS00


IST measuring capsule
Q3 = 2.5 m3/h, connecting
thread G2",
up to 30 °C

The cold water meter for the JXF:WMK636.DTE00 WMK636.DTE00


TE1 measuring capsule
Q3 = 2.5 m3/h, connecting
thread M62 x 2 mm, up to
30 °C

The cold water meter for the JXF:WMK636.DAL00 WMK636.DAL00


A34 measuring capsule
Q3 = 2.5 m3/h, connecting
thread M77 x 1.5 mm, up to
30 °C

Mechanical capsule hot water meter in S-Mode

Designation Ordering number Type

The hot water meter for the JXF:WMW636.DIS00 WMW636.DIS00


IST measuring capsule
Q3 = 2.5 m3/h, connecting
thread G2 x 1.5 mm, up to
90 °C

The hot water meter for the JXF:WMW636.DTE00 WMW636.DEL00


TE1 measuring capsule
Q3 = 2.5 m3/h, connecting
thread M62 x 2 mm, up to
90 °C

The hot water meter for the JXF:WMW636.DAL00 WMW636.DAL00


A34 measuring capsule
Q3 = 2.5 m3/h, connecting
thread M77 x 1.5 mm, up to
90 °C

9
Smart Infrastructure A6V12128928_en--_b
2022-08-16
Accessories

Accessories for screw-type meters


Order accessories separately.

Spacer

Designation Ordering number Type

Spacer G ¾", length 80 mm JXF:WFZ.R80 WFZ.R80

Spacer G ¾", length 110 mm JXF:WFZ.R110 WFZ.R110

Spacer G 1", length 130 mm JXF: WFZ.R130 WFZ.R130

Adapter pieces

Designation Ordering number Type

Adapter set 80 mm G ¾" to JXF:WZM-V110 WZM-V110


110 mm , 1",
consisting off:
2 adapter pieces G ¾" to G
1"
2 flat gaskets 2 mm, 1"

Extension set 110 mm G ¾" JXF: WZM-V130 WZM-V130


to 130 mm G ¾",
consisting off:
1 extension 27 mm
2 flat gaskets 2 mm, ¾"
1 gasket made of copper ¾"
x 1.5 mm

Extension set 110 mm G ¾" JXF: WZM-V165 WZM-V165


to 165 mm G ¾",
consisting off:
1 extension 27 mm
1 extension 42 mm
2 flat gaskets 2 mm, ¾"
1 gasket made of copper ¾"
x 1.5 mm

Extension set 110 mm G ¾" JXF: WZM-V190 WZM-V190


to 190 mm G 1",
consisting off:
2 adapter pieces from 110
mm G ¾" to 190 mm G 1"
2 flat gaskets 2 mm, 1"
1 gasket made of copper ¾"
x 1.5 mm

10
Smart Infrastructure A6V12128928_en--_b
2022-08-16
Installation sets

Designation Ordering number Type

Mounting set, pair of fittings S55563-F151 WFZ.R2


G ¾" x R ½" with gaskets

Mounting set, pair of fittings S55563-F152 WFZ.R2-1


G 1" x R ¾" with gaskets

Other

Designation Ordering number Type

Mounting kit, complete for JXF:WFZ.W WFZ.W


washstand water meters

Mounting kit for tap water JXF:WFZ.Z WFZ.Z


meters

Self-lock seal with sealing JXF:WFZ.P WFZ.P


wire

Accessories for mechanical capsule meters


Order accessories separately.
Mounting materials

Designation Ordering number Type

Single-pipe connecting piece JXF:WME.G20/OV/H WME.G20/OV/H


without cover, without seal
and plastering aid,
compatible with EAS and
VAS 2" systems, internal
threading ¾", mounting
length 80 mm

Single-pipe connecting piece JXF:WME.L15/OV/H WME.L15/OV/H


without cover, without seal,
compatible with EAS and
VAS 2" systems, ½" or
15 mm, mounting length,
soldered connector,
mounting length 110 mm

Single-pipe connecting piece JXF:WME.L18/OV/H WME.L18/OV/H


(EAT) Without cover, without
seal and plastering aid,
compatible with EAS and
VAS 2"-systems, external
threading ¾", mounting
length 130 mm

11
Smart Infrastructure A6V12128928_en--_b
2022-08-16
Single-pipe connecting piece JXF:WME.L22/OV/H WME.L22/OV/H
without cover, without seal,
without seal and plastering
aid, compatible with EAS and
VAS 2" systems, external
threading ¾" or soldered
connector, mounting length
130 mm

Profiled seal for EAS and JXF:WME.PRODICHT WME.PRODICHT


VAS 2", dimensions: 57 x 46
x 4 mm

Closure for 2" flow measuring JXF:WME-VRING WME-VRING


section

Mounting aid complete JXF:WME.EINPUTZ1 WME.EINPUTZ1

Guide piece for A341 capsule BPZ:FKK0173 FKK0173


water meter, M77 x 1.5 mm

O-ring for A34 capsule water JXF:FKS0034 FKS0034


meter, M77 x 1.5 mm

Mounting key for measuring JXF:WMZ.K5 WMZ.K5


capsule water meters

Extensions and covers

Designation Ordering number Type

Round cover with thrust tube JXF:WMXI.KCR1-001 WMXI.KCR1-001


in chrome look

Round cover with thrust tube, JXF:WMXI.KBL1-001 WMXI.KBL1-001


white

Inner extensions for thrust JXF:WMXI.KCR1-002 WMXI.KCR1-002


tube (5 pcs./PU) in chrome
look

Inner extensions for thrust JXF:WMXI.KBL1-002 WMXI.KBL1-002


tube (5 pcs./PU), white

Outer extensions for thrust JXF:WMXI.KCR1-003 WMXI.KCR1-003


tube (5 pcs./PU) in chrome
look

Outer extensions for thrust JXF:WMXI.KBL1-003 WMXI.KBL1-003


tube (5 pcs./PU), white

12
Smart Infrastructure A6V12128928_en--_b
2022-08-16
Other

Designation Ordering number Type

Sealing ring for measuring JXF:FKK0139 FKK0139


capsule meters

Self-lock seal with sealing JXF:WFZ.P WFZ.P


wire

Programming accessories for all types

Designation Ordering number Type

Readout and parameterization software JXF:ACT20 ACT50

Infrared read head (with USB interface) JXF:WFZ.IRDA- WFZ.IRDA USB


USB

Triggering tool for radio telegrams JXF:WFZ.PS WFZ.PS

Ordering
When ordering, please provide the quantity, description, type, and stock no.

Designation Ordering number Type

Electronic water meter See Type summary WFx636

Product documentation

Topic Title Document ID

Mounting instructions for Electronic water meter A6V12239416


screw-type and measuring
capsule meters

Product inserts
Two flat gaskets, a seal with sealing wire, and mounting instructions in the following
languages are provided with the water meters:
Bulgarian, German, English, Finnish, French, Greek, Dutch, Italian, Croatian, Lithuanian,
Norwegian, Polish, Romanian, Russian, Slovakian, Slovenian, Spanish, Czech, Turkish, and
Hungarian.
Related documents such as the environmental declarations, CE declarations, etc., can be
downloaded from the following Internet address:
https://siemens.com/bt/download

13
Smart Infrastructure A6V12128928_en--_b
2022-08-16
Notes
Installation
Note the following:
● The water meter can be installed horizontally or vertically.
● Ensure there is sufficient space for installation.
● Horizontal installation is more accurate (i.e. a higher meteorological class).
● The meter must be easily accessible for readout.
● Settling paths are not required, neither upstream of nor downstream from the meter.
● Install the flow measuring section between 2 shutoff valves; the arrow must be in the
direction of the flow.
● During construction, install a spacer (screw-on meter) or cover (measuring capsule
meter).
● Thoroughly flush the plant prior to installing the meter.
● Comply with all local regulations and potable water permits on the use of water meters
(installation, sealing, etc.)

Device sealing
● After mounting the meter, seal all components to prevent tampering (observe national
regulations):
● Flow measuring section with fitting (inlet)
Maintenance
The meters are maintenance-free. Comply with all national calibration regulations.
Disposal

This symbol or any other national label indicate that the product, its
packaging, and, where applicable, any batteries may not be disposed of as
domestic waste. Delete all personal data and dispose of the item(s) at
separate collection and recycling facilities in accordance with local and
national legislation.
See Siemens disposal information for additional information.

Warranty service
The technical data are only guaranteed in connection with Siemens products listed in "Type
summary" and "Accessories". Siemens rejects any and all warranties in the event that third-
party products are used.

14
Smart Infrastructure A6V12128928_en--_b
2022-08-16
Technical data

Power supply

Battery type Lithium battery (cannot be replaced)

Battery voltage 3.0 V

Battery life 1 year storage, 10 years RF operation,


1 year reserve

Display

Display 8-digit BCD

Volume indicator based on device m3: Decimal with 3 digits


configuration

Communication

Optical interface
● Protocol Per EN13757-2,3,7

RF:

Frequency band S-mode: 868.3 ±0.3 MHz;


C-mode: 868.95 ±0.25 MHz

RF protocol Wireless M-bus per EN13757-4

Transmitter power Typical 10 dBm, max. 14 dBm

Duty cycle < 1 % (50 ms/128s)

Cikd water/hot water screw-type meters

Continuous flow Q3 m3/h 2.5 2.5 4

Mounting length mm 80 110 130

Connecting thread G ¾ B" G ¾ B" G ¾ B"

Meterological class
● Horizontal R80 R80 R80
● Vertical R40 R40 R40

Overload flow rate Q4 m3/h 3.13 3.13 5.0

Minimum flow rate Q1


● Horizontal (R80) l/h 31.25 31.25 50.0
● Vertical (R40) l/h 62.5 62.5 100.0

Transitional flow rate Q2


● Horizontal (R80) l/h 50.0 50.0 80.0
● Vertical (R40) l/h 100.0 100.0 160.0

Response threshold (typical) l/h ca. 4-5 l ca. 4-5 l approx. 5-6

15
Smart Infrastructure A6V12128928_en--_b
2022-08-16
Cikd water/hot water screw-type meters

Measuring range
● Cold water meter WFK636.. 5 °C…≤30 °C
● Hot water meter WFW636.. 30 °C… ≤90 °C

Rated pressure 1.6 MPa (PN16)

Mounting position Horizontal/vertical

Display 8-digit LCD field

Cold/hot water mechanical capsule meters

Continuous flow Q3 m3/h 2.5

Meterological class
● Horizontal R80
● Vertical R40

Overload flow rate Q4 m3/h 3.13

Minimum flow rate Q1


● Horizontal (R80) l/h 31.25
● Vertical (R40) l/h 62.5

Transitional flow rate Q2


● Horizontal (R80) l/h 50.0
● Vertical (R40) l/h 100.0

Response threshold (typical) l/h ca. 4 -5 l

Measuring range
● Cold water meter WMK636.. 5 °C… ≤30 °C
● Hot water meter WMW636.. 30 °C… ≤90 °C

Rated pressure 1.6 MPa (PN16)

Mounting position Horizontal/vertical

Display 8-digit LCD field

Housing type

Protection class III

Degree of protection

Meter processor IP65 / IP68 per EN 60529

Flow measuring section IP65 / IP68 per EN 60529

16
Smart Infrastructure A6V12128928_en--_b
2022-08-16
Ambient conditions

Operation Transportation Storage

Temperature +5…+55 °C -25…+70 °C -5…+45 °C

Humidity <95 % r.h. at 25 °C (non-condensing)

Standards, directives and approvals

EU conformity (CE) See EU declaration of conformance *)

Flow profile sensitivity classes U0 / D0

Product standard ISO 4064/2

Environmental compatibility

The product environmental declaration *) contains data on environmentally compatible


product design and assessments (RoHS compliance, materials composition, packaging,
environmental benefit, disposal).

Dimensions

See "Dimensions"

Housing material

Flow measuring section Screw-type meter: Brass


Meauring capsule meter: Plastic

Totalizer Plastic

Housing colors

Totalizer Transparent

17
Smart Infrastructure A6V12128928_en--_b
2022-08-16
Weight screw-type meter WF.636..

Device packed complete with inserts 2.5 m3/h / 80 mm: 0.403 kg


2.5 m3/h / 110 mm: 0.437 kg
4 m3/h / 130 mm: 0.31 kg

Weight meauring capsule meter WM.636..

Device packed complete with inserts IST: 2.5 m3/h / G2": 0,279 kg
TE1: 2.5 m3/h / M62 x 2: 0,233 kg
A34: 2.5 m3/h / M77 x 15: 0,523 kg

*) The documents can be downloaded at http://siemens.com/bt/download.

18
Smart Infrastructure A6V12128928_en--_b
2022-08-16
Dimensions

Screwed-type water meter


Dimensions in mm
Q3 = 2.5 m3/h, L = 80 mm
71

69.7

64.4

26.4
37.2

73.9
75.1
G 3/4

G 3/4
7.9 7.9 43.6
80

Q3 = 2.5 m3/h, L = 110 mm


71

69.7

64.4

26.4
37.2

73.9
75.1
G 3/4

G 3/4

8.6 8.6 43.6

110

19
Smart Infrastructure A6V12128928_en--_b
2022-08-16
Q3 = 4 m3/h, L = 130 mm
71
69.7
64.4

26.4
37.2

73.9
78.4
G1

G1
12 12 43.6
130

Measuring capsule meter


Dimensions in mm
Typ IS, connecting thread G2"
74.8

69.7 80
64.4 76.2

27
35.3
37.2

59.6
10.8

8.4
74.9

89.1

G2
64
70.1

20
Smart Infrastructure A6V12128928_en--_b
2022-08-16
Typ AL, connecting thread M77 x 1,5 mm"
77
70.8 80
64.4 76.2

27
35.3
38.3

49.8
11.9

82.8
96.1
18

45.3
37
24.3
13.3
50.7

62.8

71.6

M77x1.5

Typ TE – Connecting thread M62 x 2 mm"


77
80
70.8
76.2
64.4

27
35.3
38.3

49.7
11.9

18
74.9

78.5
8.4

52.2
M62x2
71.2

21
Smart Infrastructure A6V12128928_en--_b
2022-08-16
Issued by
© Siemens Switzerland Ltd, 2020
Siemens Switzerland Ltd
Technical specifications and availability subject to change without notice.
Smart Infrastructure
Global Headquarters
Theilerstrasse 1a
CH-6300 Zug
+41 58 724 2424
www.siemens.com/buildingtechnologies

Document ID A6V12128928_en--_b
Edition 2022-08-16