0% found this document useful (0 votes)
188 views

Selec 600psr

This document provides information on a 600PSR-280/520 3-phase protection relay. It monitors phase sequence, phase missing, and trips below 70% of nominal voltage. It has LED indication for power on, mounts on a DIN rail, and has SPDT output contact rated for 5A NO and 3A NC. Technical specifications include accuracy of ±3%, auto reset, 100msec response time, and operating temperature range of 0-50°C.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
188 views

Selec 600psr

This document provides information on a 600PSR-280/520 3-phase protection relay. It monitors phase sequence, phase missing, and trips below 70% of nominal voltage. It has LED indication for power on, mounts on a DIN rail, and has SPDT output contact rated for 5A NO and 3A NC. Technical specifications include accuracy of ±3%, auto reset, 100msec response time, and operating temperature range of 0-50°C.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

600PSR-280/520 17.

5mm DIN Rail Protection Relay

Features:
3Ø - 3 Wire Input
!
Monitors , Phase Sequence, Phase Missing
!
LED Indication: Relay ON
!
Slim, Space Saving Design
!
DIN Rail Mount
!

Size: DIN 17.5mm


Certifications: C UL US

PENDING

Technical Specifications Dimensions


44mm
Input Specifications

Accuracy ±3% of F.S. (F.S. = Full Scale)

45mm
Reset Auto reset on removal of fault condition

67.5mm

35.3mm
90mm
Output Specifications

Output Contact SPDT (1 C/O) 17.5


mm
Contact Rating NO/5A, NC/3A@250V AC Symmetrical 35mm Din Rail (EN50022) Mouting
60mm

Functional Specifications Terminal Connections

Phase Failure Trip <70% of nominal voltage (<280V AC) L1


L2
L3
Phase Sequence, Yes
A1 A2
Phase Missing 26 28
R
Hysteresis 6V
Trip Accuracy ±10V
Response Time 100 msec max. 15
16 18
Power On Delay 100 msec NC NO

Supply Voltage COM

Cable Size (AWG): 16 ; Tightening Torque (Lb-inch): 4.5


Nominal Input Voltage 400V AC (phase to phase)
Cable Size (mm2): 1.5 ; Tightening Torque (N-m): 0.5
Power Consumption 20VA max
Operating Voltage 280 to 528V AC Timing Diagram

Environmental Specifications

Temperature Operating: 0 to 50oC (32 to 122oF)


Storage: -20 to 75oC (-4 to 167oF)
Humidity (non-condensing) 95% RH
Weight 62 gms
Protection Level IP50 for faceplate
IP40 for housing
IP20 for terminals

LED Indication Chart Ordering Information


Supply Relay LED Certification
Part No. Supply Voltage
C UL US
Nominal condition ON PENDING

600PSR-280/520 3Ø/3W, 280 to 528V AC, P-P


Phase reversed / Phase missing OFF
600PSR-280/520-CU 3Ø/3W, 280 to 528V AC, P-P

www.selec.com 1
600PSR-165/300 17.5mm DIN Rail Protection Relay

Features:
3Ø - 3 Wire Input
!
Monitors , Phase Sequence, Phase Missing
!
LED Indication: Relay ON
!
Slim, Space Saving Design
!
DIN Rail Mount
!

Size: DIN 17.5mm


Certifications: C UL US

PENDING

Technical Specifications Dimensions


44mm
Input Specifications

Accuracy ±3% of F.S. (F.S. = Full Scale)

45mm
Reset Auto reset on removal of fault condition

67.5mm

35.3mm
90mm
Output Specifications

Output Contact SPDT (1 C/O) 17.5


mm
Contact Rating NO/5A, NC/3A@250V AC Symmetrical 35mm Din Rail (EN50022) Mouting
60mm

Functional Specifications Terminal Connections


Phase Failure Trip <70% of nominal voltage (<165V AC) L1
L2
Phase Sequence, Yes L3

Phase Missing A1 A2
26 28
Hysteresis 6V R

Trip Accuracy ±10V


Response Time 100 msec max. 15
16 18
Power On Delay 100 msec
NC NO

Supply Voltage COM

Cable Size (AWG): 16 ; Tightening Torque (Lb-inch): 4.5


Nominal Input Voltage 230V AC (phase to phase)
Cable Size (mm2): 1.5 ; Tightening Torque (N-m): 0.5
Power Consumption 20VA max
Operating Voltage 165 to 300V AC
Timing Diagram

Environmental Specifications

Temperature Operating: 0 to 50oC (32 to 122oF)


Storage: -20 to 75oC (-4 to 167oF)
Humidity (non-condensing) 95% RH
Weight 62 gms
Protection Level IP50 for faceplate
IP40 for housing
IP20 for terminals

LED Indication Chart


Ordering Information
Supply Relay LED
Certification
Nominal condition ON Part No. Supply Voltage
C UL US
PENDING

Phase reversed / Phase missing OFF


600PSR-165/300 3Ø/3W, 161 to 300V AC, P-P

600PSR-165/300-CU 3Ø/3W, 161 to 300V AC, P-P

www.selec.com 2

You might also like