0% found this document useful (0 votes)
236 views

Color Code Instruction

The document provides instructions for creating AutoCAD drawings with specific color-coding rules. Key points include: 1. Drawings must be to scale in model space without layouts and follow color codes for elements. 2. Floors, blocks, and other elements need individual files and assigned colors or layers. 3. Plot boundaries, dimensions, uses, open spaces, heights and other items need unique color-coded lines, polylines, or text. 4. Details like parking, roads, and basements require specific color coding of elements.

Uploaded by

asasqz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
236 views

Color Code Instruction

The document provides instructions for creating AutoCAD drawings with specific color-coding rules. Key points include: 1. Drawings must be to scale in model space without layouts and follow color codes for elements. 2. Floors, blocks, and other elements need individual files and assigned colors or layers. 3. Plot boundaries, dimensions, uses, open spaces, heights and other items need unique color-coded lines, polylines, or text. 4. Details like parking, roads, and basements require specific color coding of elements.

Uploaded by

asasqz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Annexure - I

INSTRUCTIONS TO BE FOLLOWED FOR AUTOCAD DRAWING


(Please follow the color code for each and every item)
General:
1. Drawing must be drawn in 1:1 scale.
2. Drawing must be saved in ‘model’ space and no ‘layout’ should be defined.
3. No other elements in the drawing should be drawn using the color code as specified in Annexure –II
4. All the instructions with corresponding color codes are again summarized in the Annexure III
5. Doors/ windows/ furniture/ columns/ beams/ Landscape elements if shown in the drawing should be
drawn in ‘block’.
6. ‘Block’ should not be used in the drawing, excepting the items mentioned above.
7. All the floors starting from ground to the last floor with the assigned color of each of the floor should
be superimposed in a single drawing.
8. All the texts representing block name, building name must be drawn in single line text.
9. Each file should contain single type of block details.
10. Drawing content with assigned code should not be repeated in any of the drawing of particular premise
using the same color code.
11. The folder containing all the drawings which is to be uploaded should be named as the premises no i.e.
(XX-XXXX) format.
12. All the file names should start with premises No., i.e. (XX-XXXX) format.
13. Following instructions should be strictly followed in case of multiple blocks/buildings —
a. A master plan drawing should contain all the information details about car parking, open space,
internal road, plot dimension, building names.
b. Block drawing details should be in a separate file and should contain the information about block
height, block type and floors areas.
c. Buildings of similar design in all respect are termed as ‘Block’ which should be represented in
alphabetical type order such as Block ‘A’, Block ‘B’. The nomenclature of every block within
premises should start with ‘A’, even if there is only single block within the premises it should also
be named as ‘A’. The buildings under each type of block should be represented in alpha
numerical order e.g. A1, A2, A3...etc.
d. The name of the buildings should be mentioned in text format in color 220 on to the plan
representing the building in the master plan drawing.
e. The block type (color 220) should be mentioned in the nameplate of the corresponding block
detail drawing.
14. Drawing should be done in AUTOCAD version 4.0/ 5.0.Even if, it is drawn in any other version, other than
the specified, it should be, saved as in the above mentioned version before both upload and checking.

Page: 1 NKDA-OPS/07-12/FEB/Revised 06
Annexure - II

COLOR CODE DETAILS

Plot area & Ground a. Plot area must be demarcated using poly line (enclosed) and the color of
the poly line should be 240.
coverage area b. Ground coverage area must be demarcated using poly line (enclosed) and
the color of the poly line should be 230.
c. Front side must be drawn in color 13 and using poly line/line.
Plot Side Dimension d. Rear side must be drawn in color 23 and using poly line/line.
e. Side 1. side must be drawn in color 33 and using poly line/line.
f. Side 2. side must be drawn in color 43 and using poly line/line.
Principal use a. Must be drawn in layer named “principal”.
b. Area considered as principal use ,must be drawn in poly-line
and colored by the range of color from 100 to 150
Ex.- the color of the poly-line representing the ground floor is 100.
c. Area are not to be consider or like to subtracted from
principal use, to be drawn in same color as colored for the
principal use, with the line thickness 0.5
d. Mezzanine floor must be drawn in color 93 and using poly
line. And must be drawn in layer named “principal”
Floor Area Details
e. Mezzanine floor Area are not to be consider or like to
subtracted from principal use, to be drawn in same color as
colored for the principal use, with the line thickness 0.5 .

Mixed use a. Must be drawn in layer named “mixed”.


b. Other instructions are same as Principal use.
Facility a. Must be drawn in layer named “facility”
b. Other instructions are same as Principal use.
Utility a. Must be drawn in layer named “utility”
b. Other instructions are same as Principal use.
a. Front open space must be demarcated as a line/poly line in
color 53.
Open Space b. Rear open space must be demarcated as a line/poly line in
color 63.
for single c. Side 1 open space must be demarcated as a line/poly line in
color 73.
building d. Side 2 open space must be demarcated as a line/poly line in
color 83.
Open Space System a. Front open space must be demarcated as a line/poly line in
color range of 53-62.
Open space b. Rear open space must be demarcated as a line/poly line in
color range of 63-72.
for multiple c. Side 1 open space must be demarcated as a line/poly line in
color range of 73-82.
building d. Side 2 open space must be demarcated as a line/poly line in
color range of 83-92.
e. Mention the building name (e.g. A1, A2, B3, C9...etc.) with
that line/poly line representing the open spaces in same color.

Page: 2 NKDA-OPS/07-12/FEB/Revised 06
a. To represent a inter space you have to draw a line between
Inter space for two lines.
b. Put the names of the buildings (A1, A2, B3, C7…etc.) by the
multiple side of the building line.
c. Make groups of these three elements (one line and two text
building elements representing the building names.)
d. Do not create any other group to represent something else.

Building Height a. Building height must be demarcated using line/poly line in the drawing.
b. The color of the building height is 250.
c. For only one block in the premises the building height must put only once.
d. For multiple blocks in the premises the building height put in each block detail
drawing with no repetition.
Car parking Details a. In drawing the car must be indicated as Triangle and drawn using poly line
b. Individual cars should be drawn in color 25.
c. Cars within the cover region drew using line thickness 0.5.
d. Cars within the open region drew using line thickness 0.25
e. Covered car parking areas including driveway should be shown using enclosed
poly-line in color 45 with line thickness 0.25.
f. Any area need to be subtracted from covered car parking areas should be
drawn in color 45 with line thickness 0.50.
g. All these details should be drawn in a single file.(preferably in master plan
drawing)
Internal Road a. Length of the Internal Road should be drawn in color 46 using poly line along
the center of the road.
b. The width of the internal road should be demarcated as a line having color 47.
Basement a. Service area in basement must be drawn in color 96 (for first level basement)
and 97 (for second level basement).
b. Parking area in basement including driveway must be drawn in color 98 (for
first level basement) and 99 (for second level basement)
c. Basement for floor must be drawn in color 200 (for first level basement) and
201 (for second level basement)

Note: - 1. AutoCAD version 2004/ 2005/ 2006 must be installed to run the OPS software.
2. The AutoCAD drawing when prepared for online submission should not use any color other than
white for any layer.

3. No hatch should be done anywhere in the sanction drawing.

4. All the floor plans should contain detailed dimension.( mentioning room sizes only is not enough) .

Page: 3 NKDA-OPS/07-12/FEB/Revised 06
Annexure – III

INSTRUCTIONS AT A GLANCE

Checking Item Category Color Code Selection Basis of...


of Values (AutoCAD color
Pallet)
Plot Area : Area 240 Poly Line

Front Side : Length 13 Line/Poly Line

Rear Side : Length 23 Line/Poly Line

Side 1 Side : Length 33 Line/Poly Line

Side 2 Side : Length 43 Line/Poly Line

Basement (Floor)2 : Area 201 Poly Line

Basement(Service)2 : Area 97 Poly Line

Basement(Parking)2 : Area 99 Poly Line

Basement (Floor)1 : Area 200 Poly Line

Basement(Service)1 : Area 96 Poly Line

Basement(Parking)1 : Area 98 Poly Line

Ground Floor Service : Area 95 Poly Line

Mezzanine Floor : Area 93 Poly Line, Layer name ’principal’

Mixed for Floor(0-50) : Area 100-150 Poly Line, Layer name ‘mixed’

Predominant for Floor (0 - : Area 100-150 Poly Line, Layer name ’principal’
50)
Facility Area (0 – 50) : Area 100-150 Poly Line, Layer name ‘facility’

Utility Area (0 – 50) : Area 100-150 Poly Line, Layer name ‘utility’

Ground Coverage Area : Area 230 Poly Line

Front Open Space : Length, 53(53-62) Line/Poly Line and text represent
text the corresponding building name.

Rear Open Space : Length 63(63-72) Line/Poly Line and text represent
,text the corresponding building name.

Side 1 Open Space : Length, 73(73-82) Line/Poly Line and text represent
text the corresponding building name.

Side 2 Open Space : Length, 83(83-92) Line/Poly Line and text represent
text the corresponding building name.

Page: 4 NKDA-OPS/07-12/FEB/Revised 06
Inter Space : Length,text Other than Making groups of line and texts
mentioned color indicating building name.
code
Building Height : Length 250 Line/Poly Line

Number of Car Parking : Count 25 Poly Line

Car Parking area(Covered) : Area 45 Poly Line

Length of critical : Length 46 Poly Line


Internal Road

Width of critical : Length 47 Poly Line
Internal Road

Block Name : Text 220 Text

Page: 5 NKDA-OPS/07-12/FEB/Revised 06
Annexure – IV

REQUIREMENTS FOR SERVICE DRAWING

1. Water demand calculation will have to be done assuming 200 lpcd for residential population and 65 lpcd

for floating population.

2. Sewerage line & drainage line will have to be shown separately in one drawing sheet and water supply

line to be shown in another drawing sheet.

3. Position of departmental (P.H.E) water pipe line, manhole, master trap, sewerage line etc. to be shown

in the drawings along with connection with internal service lines.

4. For plots more than 1500 sqm. where the length of sewer and drainage line are significant, invert levels

at intermediate points are to be shown.

5. Capacity and dimensions of O.H.R, U.G.R and Fire Tank should be clearly given along with plan,

elevation and cross section in the drawing and that should satisfy the required demand.

6. Final approval of the service drawings are to be given by the P.H.E Department.

7. Location of UGR should be such that the PHED/WBHIDCO/NKDA authorities will have free access

to the said reservoir at any time.

8. Top of Manhole at least 300mm above adjacent GL, overflow line should be above GL.

Page: 6 NKDA-OPS/07-12/FEB/Revised 06
Annexure –V

REQUIREMENT FOR WATER SUPPLY

1. Calculation of water demand:

a) In residential building – number of tenement per floor and total number of person in building and

requirement @ 200 liter/cap/day.

b) For commercial building – Total carpet area of the building and number of person @10 sqm/person

and 65 liter/cap/day.

2. According to the demand calculation volume of reservoir should be checked with a total capacity of one

day’s requirement and capacity of O.H.R is 50% of UGR.

3. Portion of ferrule connection shown in the drawing should be checked with P.H.E’s water supply line or

pipe line

4. Within the premises there should be at least 4” X 4” free space over the supply line for installation of

water meter and that should be free approachable for any one.

5. The R.L on top of manhole covers such that there should not be any chance for contamination of UGR

water by interpreting of surface run off in the UGR.

6. The overflow line from UGR should be at least 100 mm over than surrounding GL so that there would

not be no chance of back flow of surface run off and contamination of UGR water.

7. There should be at least 300 mm free board in UGR from over flow line.

8. Over flow line should not be covered and while excess water from UGR drain out from the nearer

saucer drain that should not covered so that its over flowing of water can be easily visible to any habitants.

9. Inlet line should be at least 50 mm above over flow line.

Page: 7 NKDA-OPS/07-12/FEB/Revised 06
Annexure –VI

REQUIREMENT FOR SEWERAGE

1. There should be separate line for sanitary sewage and storm drainage.

2. Sanitary sewage should be discharge in nearby plot manhole.

3. Storm drainage line should be discharge in nearby box drain.

4. Position of manhole shown in the drawing should be checked with P.H.E’s drawing.

5. Invert level of the master trap should be given in the drawing and the R.L of outfall or discharge point

should be same with the R.L of manhole or provision left by P.H.E.

6. Sanitary sewer line and storm sewer line should not intersect but if it is unavoidable then R.L of

intersection point should be check and that should not be at same level.

7. Position of discharge point of storm drainage shown in drawing should be checked with P.H.E’s

drawing regarding existence of box drain at that point.