Controller CLVR02EXT-FICHA - ING

The document describes the CLVR 02EXT automatic fire detection and extinguishing control panel. It has 2 detection zones for conventional detectors or call points, plus a 3rd configurable zone. It can operate in standard, consecutive, or simultaneous extinction modes using its pre-warning output R1 and extinguishing output R2. Buttons allow manual activation/stopping of extinguishing. It has features like MODBUS connectivity and is certified to EN fire safety standards.

Uploaded by

chida moha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
49 views2 pages

Controller CLVR02EXT-FICHA - ING

The document describes the CLVR 02EXT automatic fire detection and extinguishing control panel. It has 2 detection zones for conventional detectors or call points, plus a 3rd configurable zone. It can operate in standard, consecutive, or simultaneous extinction modes using its pre-warning output R1 and extinguishing output R2. Buttons allow manual activation/stopping of extinguishing. It has features like MODBUS connectivity and is certified to EN fire safety standards.

Uploaded by

chida moha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

EXTINCTION

CLVR Extinguishing control panel


SYSTEMS

Automatic conventional fire detection and fire alarm control


panel with extinguishing functionality.

CLVR 02EXT: 2 zones extinguishing control panel.

The control panel incorporates a third configurable zone


as conventional separate zone from extinction in order to protect
against fire small areas close to the flood/extinction zone, or allow
the supervision of an external fire protection system giving a fault
indication, such as a pressure switch contact.

CLVR control panel characteristics are common among all its


models.

Features:

• 2 zones control panel with extinguishing functionality for conventional detectors and call points use.
• Third additional zone configurable as an alarm and detection zone for conventional detectors and call
points or as a monitoring input of an external fire protection system.
• Same technical features as conventional CLVR control panels (2 general sounder outputs, 1 alarm output,
1 fault output, 230Vdc outputs, test mode, threshold setup, metallic cabinet, etc).
• 3 modes of operating extinction:
- Standard mode: Output R1 of pre-warning is activated with Zone 1 or Zone 2 in alarm status.
- Consecutive mode: Output R1 is activated intermittently (1 second with Zone 1 or Zone 2 in
alarm status, 0,5 seconds with Zones 1 and 2 in alarm status, and continuing once the output R2
delay is finished).
- Simultaneous mode: Output R1 is activated with Zones 1 and 2 in alarm status.
• Stop and activation extinguishing button directly in the control panel.
• Possibility to install manual stop and activation buttons near the flood zone.
• 1 extinction output (”R2”) supervised, temporized supervised, temporized between 0 and 60 seconds,
protected by a resettable fuse.
• Delay for R2 extinguishing output reset after extinguishing activation temporized between 0 and 30
minutes.
• MODBUS protocol over RS485 on demand.
• Possibility of ON-LINE software in a PC using the MODBUS functionality.
• CONTACTID on demand.
• Certified according EN 54-2, EN 54-4 and EN 12094-1 with CE mark.

TECHNICAL FEATURES
Supply voltage 110/230VAC 50/60Hz End of line capacitor 4 K7
Output voltage 21 V Nominal Sounder output voltage 30 V/DC
Max. consumption 70 VA at 230 V/AC Environmentals conditions -10ºC +50ºC
Batteries 2 x 12 V 7 Ah SLA Size 363 x 331 x 96 mm
Extinction fuse R1/R2 0,5A/0,75A autoreset Weight (without batteries) 4,3 Kg
Batteries charger 500 mA 27 V/DC 20ºC Standard EN 54-2, EN 54-4 & EN 12094-1
Devices par zone 32 30v max. current output 1,5 A
Control panel power supply 2,2 A Extinction module fuse 1,85 A autoreset
Max. current per zone 2 mA (in standby) S1 output sounder fuse 1,85 A autoreset
S2 output sounder fuse 0,75 A autoreset

www.cofem.com
[email protected]
EXTINCTION
Wiring diagram
SYSTEMS

C NC NO C NO
S2 S1 ALARM FAULT 30V 30V 30V BAT Z1 Z2 Z3 Z4 R1 R2 24V

Example of connection with extinction

R1 R2 24V

C NC NO C NO
S2 S1 ALARM FAULT 30V 30V BAT Z1 Z2 Z3 Z4

*Note 1: The wiring diagram of the thermal probe depends of the model.
**Note 2: Zone 3 used for monitoring the pressure switch.

Example of wiring diagram with flame detectors, thermal probes and pressure switches

www.cofem.com
[email protected]

You might also like